Velocity Profiles : SLC 6-Stage II-String


S Location Dimensions Ref. Eff. Gas Characteristics

No. Height Dim-1 Dim-2 Thick. Area Vol. Velo. Ret.

/ Dia. Flow, w Time

mts mm mm mm m2 km3/hr m/sec sec

1 K-1 Cyclone - 5400 - 115 5.085 336.90 18.40 -

2 K-2 Cyclone - 5400 - 179 6.212 0.00 -

3 K-3 Cyclone - 5700 - 214 6.791 0.00 -

4 K-4 Cyclone - 5700 - 214 6.791 0.00 -

5 K-5 Cyclone - 5700 - 214 6.791 0.00 -

6 K-6 Cyclone - 5700 - 214 6.791 0.00 -

7 Kiln Riser Duct 17.5 3100 3100 214 7.14 410.40 15.97 1.10

8 Smoke Chamber - 4550 3100 214 11.01 410.40 10.35 -

9 Kiln (inlet) 68.0 4550 - 200 13.53 406.33 8.34 8.15

10 C-1 Cyclone - 6300 - 115 7.009 539.90 21.40 -

11 C-2 Cyclone - 6300 - 179 8.627 0.00 -

12 C-3 Cyclone - 6600 - 214 9.308 0.00 -

13 C-4 Cyclone - 6600 - 214 9.308 0.00 -

14 C-5 Cyclone - 6600 - 214 9.308 0.00 -

15 C-6 Cyclone - 6600 - 214 9.308 0.00 -

16 Calciner 26.5 6300 - 214 27.08 814.30 8.35 3.17

17 T.A. Duct 70.0 3000 - 214 5.20 581.87 31.11 2.25

18 Kiln Hood (throat) - 5500 5480 300/214 24.75 862.93 9.68 -

PLANT : Binani Cement - 20.06.2003