(1) Group `A'-For a sanctioned speed of 160 km. per hour- The minimum rail section to be adopt
The ballas
(2) Group `B'-For a sanctioned speed of 130 km. per hour- The minimum rail section to be adopted w
(3) Group `C'-Suburban Sections.- The minimum rail section to be adopted will be 60 Kg. in sections h
The minimum sleeper density shall be M + 7.
The ballast cushion shall be 25 cm.
(4) Group `D'-Where the maximum sanctioned speed is 100 Kms/hour, as at present.- The minimum rail
10 to 20 GMT and 44.5 Kg in section
The minimum sleeper density s
The ballast cushion shall be 20 c
SL NO TOTOAL
ITEM DESCRIPTION UNIT QUANTITY/ KM QUANTITY
No. of Rails 2*1000/(13 or 12)
1 BG (13m) nos. 154 154
kg
60 kg/m 120000 120000
52 kg/m 104000 104000
45 kg/m 90000 90000
(1000/13)*((M=13)+(n=
3 numeric depending on
numerous factor , (4 to
Sleepers 7)
nos.
M+4 1308 1308
M+5 1385 1385
M+6 1462 1462
M+7 1538 1538
7 (2*1000)/(rail length*
Fish plates no.of rail panels)
154 Rails, 13m rail length no. of rails/ no. of rail
panels
For free rails nos (pairs) 154 154
For three rail panels 51 51
For five rail panels 31 31
For ten rail panels 15 15
For twenty rail panels 8 8
2 m for MG BG= BROAD GAUGE (1676 mm) MG= METER GAUGE (1435mm)
he minimum rail section to be adopted will be 60 Kg. in section having traffic density of over 20 GMT and 52 Kgs in other sections.
The minimum sleeper density shall be 1,660 numbers per Km
The ballast cushion shall be 30 cm.
minimum rail section to be adopted will be 60 Kg. in sections having traffic density of over 20 GMT and 52 Kg. in other sections.
The minimum sleeper density shall be M+7.
The ballast cushion shall be 25 cm.
e adopted will be 60 Kg. in sections having traffic density of over 20 GMT and 52 Kg. in other sections.
per density shall be M + 7.
ushion shall be 25 cm.
ur, as at present.- The minimum rail section to be adopted will be 60 Kg in sections having traffic density of over 20 GMT, 52 Kg. in sec
10 to 20 GMT and 44.5 Kg in sections having traffic density of less than 10 GMT.
The minimum sleeper density shall be M + 7 in sections having traffic density above 10 GMT and M + 4 in sections having traffic d
The ballast cushion shall be 20 cm.
UNIT RATES
(Rs)
per piece
54
per piece
25
per piece
20
per piece
1250
4 nutbolts
2 fish plates
1000
1000
per piece
50
per piece
52
per piece
45
per piece
for 60 kg
4322
for 52 kg
3600
with 4 bolts
137
with clamps
150
= METER GAUGE (1435mm) GMT= GROSS MILLON TONNES
1 GMT= 2700 TONNES PER DAY
This value is calculated considering rail weight 60 kg/m, M+7=1538 sleepers for free rails , welded with
for free rails , welded with clamps