Professional Documents
Culture Documents
Procedure
Procedure
Condition of simulation:
Day 3 Standby.
Measure:
1. Internal Resistance of battery/cell.
2. Voltage battery/cell (no charging and
discharging).
3. Temperature battery/cell
4. Temperature room
5. Check have alarm or not in battery charger
during discharging process
Day 4 1. Charging the battery. Less than. 10hrs.
Temperature room increased to 32 degC,
2.3V/cell, current C10
2. Check have alarm or not in battery charger
3. Check voltage battery/cell every 2 hours
4. Check temperature battery every 2 hours
Day 5 Discharge the battery (current C10) until
Voltage= 1V, temperature 32degC.
Measure:
1. Internal Resistance of battery/cell.
2. Voltage battery/cell (no charging and
discharging).
3. Temperature battery/cell
4. Temperature room
5. Dimension for each battery
6. Check have alarm or not in battery charger
during discharging process
Day 6 Recharge the battery until 4 hours use floating voltage
Measure:
1. Internal Resistance of battery/cell.
2. Voltage battery/cell (no charging and
discharging).
3. Temperature battery/cell
4. Temperature room
5. Dimension for each battery
Attendees:
1. Mr. Kunlong Avatec
2. Mr. Arun Avatec
3. Pak Imam Energitama
4. Pak Syahruddin Energitama
5. Ibu Ernawati Energitama
6. Pak Otto MEI
7. Pak Sigit MEI
8. Pak Yadhi MEI
9. Pak Faizal MEI
10. Ibu Mery MEI