IBR Valves Schedule: Thermax LTD., Pune

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

POWER Division 2X23MW + 10% AGTP CCEP IBR valves

Thermax Ltd., Pune


IBR Valves Schedule Customer
DDC101_NEEPCO_AGTP NEEPCO, AGTP
Correction as
per vendor
devition
Spare
Re Valve Type Fluid Size Class Body Matl. Trim* Ends Operated Fluid Code Tag no LINE NO PID Part Code Catalogue Code Supplied by
Inuslatio Type
Valve Pipe Rev Remarks (Vendor
Fluid Code Tag No Complete Tag No Fluid Code Dia Tag # n Insul Thk Drawing # Qty (IBR / Spare or Not Indent no
Type Spec # deviation)
By Type Purpose NIBR)
1 Globe valve ASS 15 800 A105 C SW ASS VL 101A,B ASS-VL-101A,B ASS 15 B2BC 3608 H PP 101 M 102 1 VLO42C1004 VLO42C1000 Cogen 2 IBR 19955
2 Globe valve ASS 15 800 A105 C SW ASS VL 102A,B ASS-VL-102A,B ASS 15 B2BC 3603 H PP 101 M 102 1 VLO42C1004 VLO42C1000 Cogen 2 IBR 19955
3 Globe valve ASS 15 800 A105 C SW ASS VL 103A,B ASS-VL-103A,B ASS 15 B2BC 3855 H PP 101 M 102 1 VLO42C1004 VLO42C1000 Cogen 2 IBR 19955
4 Globe valve LPS 15 800 A105 B SW Deep gland LPS VL 101A,B LPS-VL-101A,B LPS 15 B1BC 3813 H PP 101 M 102 1 VLO42B1104 VLO42B1100 Cogen 2 IBR 19955
5 Globe valve LPS 15 800 A105 B SW Deep gland LPS VL 102A,B LPS-VL-102A,B LPS 15 B1BC 3814 H PP 101 M 102 1 VLO42B1104 VLO42B1100 Cogen 2 IBR 19955
6 Globe valve LPS 15 800 A105 C SW LPS VL 103A,B LPS-VL-103A,B LPS 15 B1BC 3816 H PP 101 M 102 1 VLO42C1004 VLO42C1000 Cogen 2 IBR Tr8 instead of Tr1 19955
7 Globe valve LPS 15 800 A105 C SW LPS VL 104A,B LPS-VL-104A,B LPS 15 B1BC 3911 H PP 101 M 102 1 VLO42C1004 VLO42C1000 Cogen 2 IBR Tr8 instead of Tr1 19955
8 Globe valve LPS 15 800 A105 B SW Deep gland LPS VL 105A,B LPS-VL-105A,B LPS 15 B1BC 3601 H PP 101 M 102 1 VLO42B1104 VLO42B1100 Cogen 2 IBR 19955
9 Gate valve LPS 25 800 A105 B SW LPS VG 106A,B LPS-VG-106A,B LPS 25 B1BC 105 H 50 PP 101 M 102 1 VGO42B1006 VGO42B1000 Cogen 2 IBR 19955
10 Gate valve LPS 200 150 A216 Gr WCB B BW LPS VG 107A,B LPS-VG-107A,B LPS 200 B1BC 121 H 75 PP 101 M 102 1 VGA13B1016 VGA13B1000 Cogen 2 IBR 19955
11 Globe valve LPS 15 800 A105 B SW Deep gland LPS VL 108A,B LPS-VL-108A,B LPS 15 B1BC 3656 H PP 101 M 102 1 VLO42B1104 VLO42B1100 Cogen 2 IBR 19955
12 Gate valve LPS 300 150 A216 Gr WCB B BW Motor LPS XV 109A,B LPS-XV-109A,B LPS 300 B1BC 160 H 75 PP 101 M 102 1 VGA13B3018 VGA13B3000 Cogen 2 IBR 19955
13 Gate valve LPS 25 800 A105 B SW LPS VG 111A,B LPS-VG-111A,B LPS 25 B1BC 120 H 50 PP 101 M 102 1 VGO42B1006 VGO42B1000 Cogen 2 IBR 19955
14 Gate valve LPS 200 150 A216 Gr WCB B BW LPS VG 113A,B LPS-VG-113A,B LPS 200 B1BC 104 H 75 PP 101 M 102 1 VGA13B1016 VGA13B1000 Cogen 2 IBR 19955
15 Check valve LPS 25 800 A105 C SW LPS VC 117A,B LPS-VC-117A,B LPS 25 B1BC 174 H 50 PP 101 M 102 1 VCO42C0006 VCO42C0000 Cogen 2 IBR Tr8 instead of Tr1 19955
16 Globe valve MSS 25 1500 A182 F22 D SW MSS VL 101A,B MSS-VL-101A,B MSS 25 D5AC 3592 H PP 101 M 102 1 VLQ62D1006 VLQ62D1000 Cogen 2 IBR F22 instead of F11 19955
17 Globe valve MSS 25 1500 A182 F22 D SW MSS VL 102A,B MSS-VL-102A,B MSS 25 D5AC 3592 H PP 101 M 102 1 VLQ62D1006 VLQ62D1000 Cogen 2 IBR F22 instead of F11 19955
18 Globe valve MSS 25 1500 A182 F22 D SW MSS VL 103A,B MSS-VL-103A,B MSS 25 D5AC 3906 H PP 101 M 102 1 VLQ62D1006 VLQ62D1000 Cogen 2 IBR F22 instead of F11 19955
19 Globe valve MSS 25 1500 A182 F22 D SW MSS VL 104A,B MSS-VL-104A,B MSS 25 D5AC 3906 H PP 101 M 102 1 VLQ62D1006 VLQ62D1000 Cogen 2 IBR F22 instead of F11 19955
20 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 105A,B MSS-VG-105A,B MSS 25 D5AC 140 H 100 PP 101 M 102 1 VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
21 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 106A,B MSS-VG-106A,B MSS 25 D5AC 140 H 100 PP 101 M 102 1 VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
22 Gate valve MSS 150 900 A217 Gr WC6 D BW MSS VG 107A,B MSS-VG-107A,B MSS 150 D5AC 130 H 150 PP 101 M 102 1 VGC53D1015 VGC53D1000 Cogen 2 IBR 19955
Rating #600 instead
23 Check valve MSS 50 600 A217 Gr WC6 D BW MSS VC 121A,B MSS-VC-121A,B MSS 50 D2AC 173 H 125 PP 101 M 102 1 VCC33D0009 VCC33D0000 Cogen 2 IBR of #300 19955
24 Gate valve MSS 150 900 A217 Gr WC6 D BW MSS VG 108A,B MSS-VG-108A,B MSS 150 D5AC 179 H 150 PP 101 M 102 1 VGC53D1015 VGC53D1000 Cogen 2 IBR 19955
25 Gate valve MSS 200 900 A217 Gr WC6 D BW Motor IBV MSS XV 109A,B MSS-XV-109A,B MSS 200 D5AC 162 H 150 PP 101 M 102 1 VGC53D3016 VGC53D3000 Cogen 2 IBR 19955
26 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 110A,B MSS-VG-110A,B MSS 25 D5AC 113 H 100 PP 101 M 102 1 VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
27 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 111A,B MSS-VG-111A,B MSS 25 D5AC 113 H 100 PP 101 M 102 1 VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
28 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 112A,B MSS-VG-112A,B MSS 25 D5AC 136 H 100 PP 101 M 102 1 VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
29 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 113A,B MSS-VG-113A,B MSS 25 D5AC 132 H 100 PP 101 M 102 1 VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
30 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 114A,B MSS-VG-114A,B MSS 25 D5AC 136 H 100 PP 101 M 102 1 VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
31 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 115A,B MSS-VG-115A,B MSS 25 D5AC 132 H 100 PP 101 M 102 1 VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
32 Gate valve MSS 40 1500 A182 F22 D SW MSS VG 116A,B MSS-VG-116A,B MSS 40 D5AC 122 H 125 PP 101 M 102 1 VGQ62D1008 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
33 Globe valve MSS 40 1500 A182 F22 D SW MSS VL 117A,B MSS-VL-117A,B MSS 40 D5AC 123 H 125 PP 101 M 102 1 VLQ62D1008 VLQ62D1000 Cogen 2 IBR F22 instead of F11 19955
34 Gate valve MSS 80 900 A217 Gr WC6 D BW MSS VG 118A,B MSS-VG-118A,B MSS 80 D5AC 119 H 125 PP 101 M 102 1 VGC53D1011 VGC53D1000 Cogen 2 IBR 19955
35 Check valve MSS 25 800 A182 F22 D SW MSS VC 166A,B MSS-VC-166A,B MSS 25 D2AC 172 H 100 PP 101 M 102 1 VCQ42D0006 VCQ42D0000 Cogen 2 IBR F22 instead of F11 19955
36 Gate valve LPS 300 150 A216 Gr WCB B BW Motor LPS XV 110A,B LPS-XV-110A,B LPS 300 B1BC 169 H 75 PP 101 M 103 1 VGA13B3018 VGA13B3000 Cogen 2 IBR 19955
37 Gate valve LPS 25 800 A105 B SW LPS VG 112A,B LPS-VG-112A,B LPS 25 B1BC 203 H 50 PP 101 M 103 1 VGO42B1006 VGO42B1000 Cogen 2 IBR 19955
38 Gate valve LPS 50 800 A105 B SW LPS VG 115A,B LPS-VG-115A,B LPS 50 B1BC 201 H 50 PP 101 M 103 1 VGO42B1009 VGO42B1000 Cogen 2 IBR 19955
Tr8 instead of Tr1 &
Rating #1500
39 Globe valve LPS 50 1500 A105 C SW Motor INCHING LPS XV 149A,B LPS-XV-149A,B LPS 50 B1BC 201 H 50 PP 101 M 103 1 NI00003878 NI00003800 Cogen 2 IBR instead of #800 19955
40 Gate valve MSS 50 1500 A182 F22 D SW MSS VG 119A,B MSS-VG-119A,B MSS 50 D5AC 186 H 125 PP 101 M 103 1 VGQ62D1009 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
41 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 120A,B MSS-VG-120A,B MSS 25 D5AC 188 H 100 PP 101 M 103 1 VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
42 Gate valve MSS 250 900 A217 Gr WC6 D BW Motor IBV MSS XV 122A,B MSS-XV-122A,B MSS 250 D5AC 108 H 220.0 mm PP 101 M 103 1 VGC53D3017 VGC53D3000 Cogen 2 IBR 19955
43 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 123A,B MSS-VG-123A,B MSS 25 D5AC 188 H 100 PP 101 M 103 1 VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
44 Globe valve MSS 50 1500 A182 F22 D SW Motor INCHING MSS XV 150A,B MSS-XV-150A,B MSS 50 D5AC 186 H 125 PP 101 M 103 1 VLQ62D3009 VLQ62D3000 Cogen 2 IBR F22 instead of F11 19955
45 Gate valve LPS 25 800 A105 B SW LPS VG 118A,B LPS-VG-118A,B LPS 25 B1BC 304 H 50 PP 101 M 104 1(1OF2) VGO42B1006 VGO42B1000 Cogen 2 IBR 19955
46 Gate valve LPS 25 800 A105 B SW LPS VG 121A,B LPS-VG-121A,B LPS 25 B1BC 307 H 50 PP 101 M 104 1(1OF2) VGO42B1006 VGO42B1000 Cogen 2 IBR 19955
47 Gate valve LPS 25 800 A105 B SW LPS VG 122A,B LPS-VG-122A,B LPS 25 B1BC 224 H 50 PP 101 M 104 1(1OF2) VGO42B1006 VGO42B1000 Cogen 2 IBR 19955
48 Gate valve LPS 25 800 A105 B SW LPS VG 123A,B LPS-VG-123A,B LPS 25 B1BC 293 H 50 PP 101 M 104 1(1OF2) VGO42B1006 VGO42B1000 Cogen 2 IBR 19955
49 Gate valve LPS 25 800 A105 B SW LPS VG 124A,B LPS-VG-124A,B LPS 25 B1BC 309 H 50 PP 101 M 104 1(1OF2) VGO42B1006 VGO42B1000 Cogen 2 IBR 19955
50 Gate valve LPS 25 800 A105 B SW LPS VG 125A,B LPS-VG-125A,B LPS 25 B1BC 304 H 50 PP 101 M 104 1(1OF2) VGO42B1006 VGO42B1000 Cogen 2 IBR 19955
51 Globe valve LPS 25 800 A105 C SW LPS VL 128A,B LPS-VL-128A,B LPS 25 B1BC 302 H 50 PP 101 M 104 1(1OF2) VLO42C1006 VLO42C1000 Cogen 2 IBR Tr8 instead of Tr1 19955
52 Globe valve LPS 25 800 A105 C SW LPS VL 129A,B LPS-VL-129A,B LPS 25 B1BC 228 H 50 PP 101 M 104 1(1OF2) VLO42C1006 VLO42C1000 Cogen 2 IBR Tr8 instead of Tr1 19955
53 Gate valve LPS 25 800 A105 B SW LPS VG 132A,B LPS-VG-132A,B LPS 25 B1BC 284 H 50 PP 101 M 104 1(1OF2) VGO42B1006 VGO42B1000 Cogen 2 IBR 19955
54 Gate valve 25 800 A105 B SW LPS VG 141A,B LPS-VG-141A,B 25 B1BC VGO42B1006 VGO42B1000 Cogen 2 IBR spare 19955
55 Globe valve LPS 25 800 A105 C SW LPS VL 143A,B LPS-VL-143A,B LPS 25 B1BC 283 H 50 PP 101 M 104 1(1OF2) VLO42C1006 VLO42C1000 Cogen 2 IBR Tr8 instead of Tr1 19955
56 Gate valve LPS 25 800 A105 B SW LPS VG 145A,B LPS-VG-145A,B LPS 25 B1BC 309 H 50 PP 101 M 104 1(1OF2) VGO42B1006 VGO42B1000 Cogen 2 IBR 19955
57 Globe valve LPS 25 800 A105 C SW LPS VL 146A,B LPS-VL-146A,B LPS 25 B1BC 301 H 50 PP 101 M 104 1(1OF2) VLO42C1006 VLO42C1000 Cogen 2 IBR Tr8 instead of Tr1 19955
58 Globe valve LPS 25 800 A105 C SW LPS VL 147A,B LPS-VL-147A,B LPS 25 B1BC 227 H 50 PP 101 M 104 1(1OF2) VLO42C1006 VLO42C1000 Cogen 2 IBR Tr8 instead of Tr1 19955
59 Gate valve LPS 25 800 A105 B SW LPS VG 148A,B LPS-VG-148A,B LPS 25 B1BC 224 H 50 PP 101 M 104 1(1OF2) VGO42B1006 VGO42B1000 Cogen 2 IBR 19955
60 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 125A,B MSS-VG-125A,B MSS 25 D5AC 373 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
61 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 126A,B MSS-VG-126A,B MSS 25 D5AC 271 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
62 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 127A,B MSS-VG-127A,B MSS 25 D5AC 254 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
63 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 128A,B MSS-VG-128A,B MSS 25 D5AC 217 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
64 Globe valve MSS 25 1500 A182 F22 D SW MSS VL 129A,B MSS-VL-129A,B MSS 25 D5AC 258 H 100 PP 101 M 104 1(1OF2) VLQ62D1006 VLQ62D1000 Cogen 2 IBR F22 instead of F11 19955
65 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 130A,B MSS-VG-130A,B MSS 25 D5AC 254 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
66 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 131A,B MSS-VG-131A,B MSS 25 D5AC 371 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
67 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 132A,B MSS-VG-132A,B MSS 25 D5AC 246 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
68 Globe valve MSS 25 1500 A182 F22 D SW MSS VL 133A,B MSS-VL-133A,B MSS 25 D5AC 217 H 100 PP 101 M 104 1(1OF2) VLQ62D1006 VLQ62D1000 Cogen 2 IBR F22 instead of F11 19955
69 Globe valve MSS 25 1500 A182 F22 D SW Motor MSS XV 134A,B MSS-XV-134A,B MSS 25 D5AC 371 H 75 PP 101 M 104 1(1OF2) VLQ62D3006 VLQ62D3000 Cogen 2 IBR F22 instead of F11 19955
70 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 135A,B MSS-VG-135A,B MSS 25 D5AC 374 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
71 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 136A,B MSS-VG-136A,B MSS 25 D5AC 218 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
72 Globe valve MSS 25 1500 A182 F22 D SW MSS VL 137A,B MSS-VL-137A,B MSS 25 D5AC 214 H 100 PP 101 M 104 1(1OF2) VLQ62D1006 VLQ62D1000 Cogen 2 IBR F22 instead of F11 19955
73 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 138A,B MSS-VG-138A,B MSS 25 D5AC 268 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
74 Globe valve MSS 25 1500 A182 F22 D SW Motor MSS XV 139A,B MSS-XV-139A,B MSS 25 D5AC 373 H 100 PP 101 M 104 1(1OF2) VLQ62D3006 VLQ62D3000 Cogen 2 IBR F22 instead of F11 19955
75 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 140A,B MSS-VG-140A,B MSS 25 D5AC 222 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
76 Globe valve MSS 25 1500 A182 F22 D SW MSS VL 141A,B MSS-VL-141A,B MSS 25 D5AC 268 H 100 PP 101 M 104 1(1OF2) VLQ62D1006 VLQ62D1000 Cogen 2 IBR F22 instead of F11 19955
77 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 142A,B MSS-VG-142A,B MSS 25 D5AC 258 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
78 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 143A,B MSS-VG-143A,B MSS 25 D5AC 222 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
79 Globe valve MSS 25 1500 A182 F22 D SW MSS VL 144A,B MSS-VL-144A,B MSS 25 D5AC 235 H 100 PP 101 M 104 1(1OF2) VLQ62D1006 VLQ62D1000 Cogen 2 IBR F22 instead of F11 19955
80 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 145A,B MSS-VG-145A,B MSS 25 D5AC 214 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
81 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 146A,B MSS-VG-146A,B MSS 25 D5AC 271 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
82 Globe valve MSS 25 1500 A182 F22 D SW MSS VL 147A,B MSS-VL-147A,B MSS 25 D5AC 218 H 100 PP 101 M 104 1(1OF2) VLQ62D1006 VLQ62D1000 Cogen 2 IBR F22 instead of F11 19955
83 Globe valve MSS 25 1500 A182 F22 D SW MSS VL 148A,B MSS-VL-148A,B MSS 25 D5AC 246 H 100 PP 101 M 104 1(1OF2) VLQ62D1006 VLQ62D1000 Cogen 2 IBR F22 instead of F11 19955
84 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 149A,B MSS-VG-149A,B MSS 25 D5AC 372 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
85 Globe valve MSS 25 1500 A182 F22 D SW Motor MSS XV 151A,B MSS-XV-151A,B MSS 25 D5AC 374 H 100 PP 101 M 104 1(1OF2) VLQ62D3006 VLQ62D3000 Cogen 2 IBR F22 instead of F11 19955
86 Globe valve 25 1500 A182 F22 D SW MSS VL 152A,B MSS-VL-152A,B 25 D5AC VLQ62D1006 VLQ62D1000 Cogen 2 IBR spare F22 instead of F11 19955
87 Globe valve MSS 25 1500 A182 F22 D SW MSS VL 153A,B MSS-VL-153A,B MSS 25 D5AC 241 H 100 PP 101 M 104 1(1OF2) VLQ62D1006 VLQ62D1000 Cogen 2 IBR F22 instead of F11 19955
88 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 154A,B MSS-VG-154A,B MSS 25 D5AC 238 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
89 Gate valve 25 1500 A182 F22 D SW MSS VG 155A,B MSS-VG-155A,B 25 D5AC VGQ62D1006 VGQ62D1000 Cogen 2 IBR spare F22 instead of F11 19955
90 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 156A,B MSS-VG-156A,B MSS 25 D5AC 267 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
91 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 157A,B MSS-VG-157A,B MSS 25 D5AC 238 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
92 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 158A,B MSS-VG-158A,B MSS 25 D5AC 264 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
93 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 159A,B MSS-VG-159A,B MSS 25 D5AC 241 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
94 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 160A,B MSS-VG-160A,B MSS 25 D5AC 275 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
95 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 161A,B MSS-VG-161A,B MSS 25 D5AC 280 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
96 Globe valve MSS 25 1500 A182 F22 D SW MSS VL 162A,B MSS-VL-162A,B MSS 25 D5AC 280 H 100 PP 101 M 104 1(1OF2) VLQ62D1006 VLQ62D1000 Cogen 2 IBR F22 instead of F11 19955
97 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 163A,B MSS-VG-163A,B MSS 25 D5AC 275 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
98 Gate valve MSS 25 1500 A182 F22 D SW MSS VG 164A,B MSS-VG-164A,B MSS 25 D5AC 235 H 100 PP 101 M 104 1(1OF2) VGQ62D1006 VGQ62D1000 Cogen 2 IBR F22 instead of F11 19955
99 Globe valve MSS 25 1500 A182 F22 D SW Motor MSS XV 165A,B MSS-XV-165A,B MSS 25 D5AC 372 H 100 PP 101 M 104 1(1OF2) VLQ62D3006 VLQ62D3000 Cogen 2 IBR F22 instead of F11 19955
100 Globe valve ASS 25 800 A105 C SW ASS VL 104A,B ASS-VL-104A,B ASS 25 B2BC 327 H 100 PP 101 M 104 1(2OF2) 0 VLO42C1006 VLO42C1000 Cogen 2 IBR Tr8 instead of Tr1 19955
101 Gate valve ASS 25 800 A105 C SW ASS VG 105A,B ASS-VG-105A,B ASS 25 B2BC 312 H 100 PP 101 M 104 1(2OF2) 0 VGO42C1006 VGO42C1000 Cogen 2 IBR 19955
102 Gate valve ASS 25 800 A105 C SW ASS VG 106A,B ASS-VG-106A,B ASS 25 B2BC 312 H 100 PP 101 M 104 1(2OF2) 0 VGO42C1006 VGO42C1000 Cogen 2 IBR Tr8 instead of Tr1 & 19955
Rating #1500
103 Globe valve LPS 25 1500 A105 C SW Motor LPS XV 119A,B LPS-XV-119A,B LPS 25 B1BC 336 H 50 PP 101 M 104 1(2OF2) 0 NI00003877 NI00003800 Cogen 2 IBR instead of #800 19955
Tr8 instead of Tr1 &
Rating #1500
104 Globe valve LPS 25 1500 A105 C SW Motor LPS XV 120A,B LPS-XV-120A,B LPS 25 B1BC 354 H 50 PP 101 M 104 1(2OF2) 0 NI00003877 NI00003800 Cogen 2 IBR instead of #800 19955
105 Globe valve LPS 25 800 A105 C SW LPS VL 126A,B LPS-VL-126A,B LPS 25 B1BC 347 H 50 PP 101 M 104 1(2OF2) 0 VLO42C1006 VLO42C1000 Cogen 2 IBR Tr8 instead of Tr1 19955
Tr8 instead of Tr1 &
Rating #1500
106 Globe valve LPS 25 1500 A105 C SW Motor LPS XV 127A,B LPS-XV-127A,B LPS 25 B1BC 346 H 50 PP 101 M 104 1(2OF2) 0 NI00003877 NI00003800 Cogen 2 IBR instead of #800 19955
Tr8 instead of Tr1 &
Rating #1500
107 Globe valve LPS 25 1500 A105 C SW Motor LPS XV 130A,B LPS-XV-130A,B LPS 25 B1BC 356 H 50 PP 101 M 104 1(2OF2) 0 NI00003877 NI00003800 Cogen 2 IBR instead of #800 19955
108 Globe valve LPS 25 800 A105 C SW LPS VL 131A,B LPS-VL-131A,B LPS 25 B1BC 352 H 50 PP 101 M 104 1(2OF2) 0 VLO42C1006 VLO42C1000 Cogen 2 IBR Tr8 instead of Tr1 19955
109 Globe valve LPS 25 800 A105 C SW LPS VL 133A,B LPS-VL-133A,B LPS 25 B1BC 357 H 50 PP 101 M 104 1(2OF2) 0 VLO42C1006 VLO42C1000 Cogen 2 IBR Tr8 instead of Tr1 19955
110 Globe valve LPS 25 800 A105 C SW LPS VL 134A,B LPS-VL-134A,B LPS 25 B1BC 337 H 50 PP 101 M 104 1(2OF2) 0 VLO42C1006 VLO42C1000 Cogen 2 IBR Tr8 instead of Tr1 19955
111 Globe valve 25 800 A105 C SW Deep gland LPS VL 135A,B LPS-VL-135A,B 25 B1BC VLO42B1106 VLO42B1100 Cogen 2 IBR spare Tr8 instead of Tr1 19955
112 Gate valve LPS 25 800 A105 B SW LPS VG 136A,B LPS-VG-136A,B LPS 25 B1BC 319 H 50 PP 101 M 104 1(2OF2) 0 VGO42B1006 VGO42B1000 Cogen 2 IBR 19955
113 Gate valve LPS 25 800 A105 B SW LPS VG 137A,B LPS-VG-137A,B LPS 25 B1BC 319 H 50 PP 101 M 104 1(2OF2) 0 VGO42B1006 VGO42B1000 Cogen 2 IBR 19955
114 Globe valve LPS 25 800 A105 C SW LPS VL 138A,B LPS-VL-138A,B LPS 25 B1BC 320 H 50 PP 101 M 104 1(2OF2) 0 VLO42C1006 VLO42C1000 Cogen 2 IBR Tr8 instead of Tr1 19955
115 Gate valve 25 800 A105 B SW Deep gland LPS VG 139A,B LPS-VG-139A,B 25 B1BC VGO42B1106 VGO42B1100 Cogen 2 IBR spare 19955
116 Gate valve 25 800 A105 B SW Deep gland LPS VG 140A,B LPS-VG-140A,B 25 B1BC VGO42B1106 VGO42B1100 Cogen 2 IBR spare 19955
117 Globe valve 25 800 A105 C SW Deep gland LPS VL 142A,B LPS-VL-142A,B 25 B1BC VLO42B1106 VLO42B1100 Cogen 2 IBR spare Tr8 instead of Tr1 19955
118 Gate valve 25 800 A105 B SW Deep gland LPS VG 150A,B LPS-VG-150A,B 25 B1BC VGO42B1106 VGO42B1100 Cogen 2 IBR spare 19955
119 Gate valve 25 800 A105 B SW Deep gland LPS VG 144A,B LPS-VG-144A,B 25 B1BC VGO42B1106 VGO42B1100 Cogen 2 IBR spare 19955
120 Gate valve LPS 300 150 A216 Gr WCB B BW Motor LPS XV 116 LPS-XV-116 LPS 300 B1BC 364 H 50 PP 101 M 110 1 0 VGA13B3018 VGA13B3000 Cogen 1 IBR 19955
121 Gate valve MSS 250 600 A216 Gr WCB D BW Motor MSS XV 124 MSS-XV-124 MSS 250 B3BC 365 H 50 PP 101 M 110 1 0 VGA33D3017 VGA33D3000 Cogen 1 IBR 19955
Braided graphite
A216 WCB instead
of A105
300# instead of
Deep gland 800#, BW instead of
124 Globe valve LPS 50 800 A105 B SW Motor ON-OFF LPS XV 151A,B LPS-XV-151A,B LPS 50 B1BC H 50 PP 101 M 104 1(2OF2) 0 NI00005069 NI00005000 Cogen 2 IBR SW 19955
125 Check valve 25 800 A182 F22 D SW VC -VC- 25 D2AC 100 PP 101 M 102 1 VCQ42D0006 VCQ42D0000 Cogen 2 IBR spare F22 instead of F11 19955
126 Gate valve 25 1500 A182 F22 D SW SP VG 01 SP-VG-01 25 D5AC VGQ62D1006 VGQ62D1000 Cogen 1 IBR spare F22 instead of F11 19955
127 Globe valve 25 1500 A182 F22 D SW SP VL 84 SP-VL-84 25 D5AC VLQ62D1006 VLQ62D1000 Cogen 1 IBR spare F22 instead of F11 19955
128 Check valve 25 800 A105 C SW VC -VC- 25 B1BC VCO42C0006 VCO42C0000 Cogen 2 IBR spare Tr8 instead of Tr1 19955
129 Globe valve 15 800 A105 C SW VL -VL- 15 B1BC VLO42C1004 VLO42C1000 Cogen 10 IBR spare Tr8 instead of Tr1 19955
130 Globe valve 25 800 A105 C SW SP VL 87 SP-VL-87 25 B1BC VLO42C1006 VLO42C1000 Cogen 1 IBR spare Tr8 instead of Tr1 19955
131 Gate valve 25 1500 A182 F22 D SW SP VG 02 SP-VG-02 25 D5AC VGQ62D1006 VGQ62D1000 Cogen 1 IBR spare F22 instead of F11 19955
132 Gate valve 25 1500 A182 F22 D SW SP VG 03 SP-VG-03 25 D5AC VGQ62D1006 VGQ62D1000 Cogen 1 IBR spare F22 instead of F11 19955
133 Gate valve 25 1500 A182 F22 D SW SP VG 04 SP-VG-04 25 D5AC VGQ62D1006 VGQ62D1000 Cogen 1 IBR spare F22 instead of F11 19955
134 Gate valve 25 1500 A182 F22 D SW SP VG 05 SP-VG-05 25 D5AC VGQ62D1006 VGQ62D1000 Cogen 1 IBR spare F22 instead of F11 19955
135 Gate valve 25 1500 A182 F22 D SW SP VG 06 SP-VG-06 25 D5AC VGQ62D1006 VGQ62D1000 Cogen 1 IBR spare F22 instead of F11 lot 2
136 Gate valve 25 1500 A182 F22 D SW SP VG 07 SP-VG-07 25 D5AC VGQ62D1006 VGQ62D1000 Cogen 1 IBR spare F22 instead of F11 lot 2
137 Gate valve 25 1500 A182 F22 D SW SP VG 08 SP-VG-08 25 D5AC VGQ62D1006 VGQ62D1000 Cogen 1 IBR spare F22 instead of F11 lot 2
138 Gate valve 25 1500 A182 F22 D SW SP VG 09 SP-VG-09 25 D5AC VGQ62D1006 VGQ62D1000 Cogen 1 IBR spare F22 instead of F11 lot 2
139 Gate valve 25 1500 A182 F22 D SW SP VG 10 SP-VG-10 25 D5AC VGQ62D1006 VGQ62D1000 Cogen 1 IBR spare F22 instead of F11 lot 2
140 Gate valve 25 1500 A182 F22 D SW SP VG 11 SP-VG-11 25 D5AC VGQ62D1006 VGQ62D1000 Cogen 1 IBR spare F22 instead of F11 lot 2
141 Gate valve 25 1500 A182 F22 D SW SP VG 12 SP-VG-12 25 D5AC VGQ62D1006 VGQ62D1000 Cogen 1 IBR spare F22 instead of F11 lot 2
142 Gate valve 25 1500 A182 F22 D SW SP VG 13 SP-VG-13 25 D5AC VGQ62D1006 VGQ62D1000 Cogen 1 IBR spare F22 instead of F11 lot 2
143 Gate valve 25 1500 A182 F22 D SW SP VG 14 SP-VG-14 25 D5AC VGQ62D1006 VGQ62D1000 Cogen 1 IBR spare F22 instead of F11 lot 2
144 Gate valve 25 1500 A182 F22 D SW SP VG 15 SP-VG-15 25 D5AC VGQ62D1006 VGQ62D1000 Cogen 1 IBR spare F22 instead of F11 lot 2
145 Gate valve 25 1500 A182 F22 D SW SP VG 16 SP-VG-16 25 D5AC VGQ62D1006 VGQ62D1000 Cogen 1 IBR spare F22 instead of F11 lot 2
146 Gate valve 25 1500 A182 F22 D SW SP VG 17 SP-VG-17 25 D5AC VGQ62D1006 VGQ62D1000 Cogen 1 IBR spare F22 instead of F11 lot 2
147 Gate valve 25 1500 A182 F22 D SW SP VG 18 SP-VG-18 25 D5AC VGQ62D1006 VGQ62D1000 Cogen 1 IBR spare F22 instead of F11 lot 2
148 Gate valve 25 1500 A182 F22 D SW SP VG 19 SP-VG-19 25 D5AC VGQ62D1006 VGQ62D1000 Cogen 1 IBR spare F22 instead of F11 lot 2
149 Gate valve 25 1500 A182 F22 D SW SP VG 20 SP-VG-20 25 D5AC VGQ62D1006 VGQ62D1000 Cogen 1 IBR spare F22 instead of F11 lot 2
150 Gate valve 25 1500 A182 F22 D SW SP VG 21 SP-VG-21 25 D5AC VGQ62D1006 VGQ62D1000 Cogen 1 IBR spare F22 instead of F11 lot 2
151 Gate valve 25 1500 A182 F22 D SW SP VG 22 SP-VG-22 25 D5AC VGQ62D1006 VGQ62D1000 Cogen 1 IBR spare F22 instead of F11 lot 2
152 Gate valve 25 1500 A182 F22 D SW SP VG 23 SP-VG-23 25 D5AC VGQ62D1006 VGQ62D1000 Cogen 1 IBR spare F22 instead of F11 lot 2
153 Gate valve 25 800 A105 B SW LPS VG 24 LPS-VG-24 25 B1BC VGO42B1006 VGO42B1000 Cogen 1 IBR spare lot 2
154 Gate valve 25 800 A105 B SW LPS VG 25 LPS-VG-25 25 B1BC VGO42B1006 VGO42B1000 Cogen 1 IBR spare lot 2
155 Gate valve 25 800 A105 B SW LPS VG 26 LPS-VG-26 25 B1BC VGO42B1006 VGO42B1000 Cogen 1 IBR spare lot 2
156 Gate valve 25 800 A105 B SW LPS VG 27 LPS-VG-27 25 B1BC VGO42B1006 VGO42B1000 Cogen 1 IBR spare lot 2
157 Gate valve 25 800 A105 B SW LPS VG 28 LPS-VG-28 25 B1BC VGO42B1006 VGO42B1000 Cogen 1 IBR spare lot 2
158 Gate valve 25 800 A105 B SW LPS VG 29 LPS-VG-29 25 B1BC VGO42B1006 VGO42B1000 Cogen 1 IBR spare lot 2
159 Gate valve 25 800 A105 B SW LPS VG 30 LPS-VG-30 25 B1BC VGO42B1006 VGO42B1000 Cogen 1 IBR spare lot 2
160 Gate valve 25 800 A105 B SW LPS VG 31 LPS-VG-31 25 B1BC VGO42B1006 VGO42B1000 Cogen 1 IBR spare lot 2
161 Gate valve 25 800 A105 B SW LPS VG 32 LPS-VG-32 25 B1BC VGO42B1006 VGO42B1000 Cogen 1 IBR spare lot 2
162 Globe valve 25 1500 A182 F22 D SW SP VL 85 SP-VL-85 25 D5AC VLQ62D1006 VLQ62D1000 Cogen 1 IBR spare F22 instead of F11 19955
163 Globe valve 25 1500 A182 F22 D SW SP VL 86 SP-VL-86 25 D5AC VLQ62D1006 VLQ62D1000 Cogen 1 IBR spare F22 instead of F11 19955
164 Globe valve 25 1500 A182 F22 D SW SP VL SP-VL- 25 D5AC VLQ62D1006 VLQ62D1000 Cogen 1 IBR spare F22 instead of F11 19955
165 Globe valve 25 1500 A182 F22 D SW SP VL SP-VL- 25 D5AC VLQ62D1006 VLQ62D1000 Cogen 1 IBR spare F22 instead of F11 19955
166 Globe valve 25 800 A105 C SW SP VL 88 SP-VL-88 25 B1BC VLO42C1006 VLO42C1000 Cogen 1 IBR spare Tr8 instead of Tr1 19955
167 Globe valve 25 800 A105 C SW SP VL 89 SP-VL-89 25 B1BC VLO42C1006 VLO42C1000 Cogen 1 IBR spare Tr8 instead of Tr1 19955
168 Globe valve 25 800 A105 C SW SP VL 90 SP-VL-90 25 B1BC VLO42C1006 VLO42C1000 Cogen 1 IBR spare Tr8 instead of Tr1 19955
169 Globe valve 25 800 A105 C SW SP VL SP-VL- 25 B1BC VLO42C1006 VLO42C1000 Cogen 1 IBR spare Tr8 instead of Tr1 19955
170 Globe valve 25 800 A105 C SW SP VL SP-VL- 25 B1BC VLO42C1006 VLO42C1000 Cogen 1 IBR spare Tr8 instead of Tr1 19955
171 Globe valve 25 800 A105 C SW SP VL SP-VL- 25 B1BC VLO42C1006 VLO42C1000 Cogen 1 IBR spare Tr8 instead of Tr1 19955
172 Globe valve 25 800 A105 C SW SP VL SP-VL- 25 B1BC VLO42C1006 VLO42C1000 Cogen 1 IBR spare Tr8 instead of Tr1 19955
173 Globe valve 25 800 A105 C SW SP VL SP-VL- 25 B1BC VLO42C1006 VLO42C1000 Cogen 1 IBR spare Tr8 instead of Tr1 19955
174 Globe valve 25 800 A105 C SW SP VL SP-VL- 25 B1BC VLO42C1006 VLO42C1000 Cogen 1 IBR spare Tr8 instead of Tr1 19955

You might also like