Checking and adjusting the frequency of flashes of the MSL-3 Beacon

Lighting and light-signaling equipment


Measure the frequency of flashes of the beacon according to the stopwatch,
which should be 90 ± 13 flashes per minute at rated voltage and temperature in
the range from -60 to +60 r С. If necessary, adjust the number of revolutions of
the rotating platform of the beacon, for which: - unlock and unscrew three
screws 6 (Fig. 21) fastening the cover of the beacon, - remove the cover 5, -
loosen the screw 4 of the sliders 3 of the adjusting resistance 2; - adjust the
number of revolutions by moving the slider 3. After adjusting the screw 4 of
the slider, tighten and cover with red enamel; - after adjusting the speed, put the
cover 5 back in place, fix it with three screws6, counter screws. To avoid
overheating of the lighthouse, its operation without blowing is allowed no more
than 10
minutes. 

 
Fig. 21. Scheme for adjusting the flashing frequency of the MSL-3 beacon:
1 — the MSL-3 flashing beacon; 
2 — adjusting resistance;
 3 - slider; 
4 screw for fixing the slider; 
5 — cover of the beacon body; 
6 - cover fixing screw

Testing Equipment
Stopwatch  
Tool and fixture
Watch screwdriver 8AT-9107-30,
screwdriver / = 150 mm,
pliers / = 150 8LT-9100-01-3
Consumable material
Cotton napkin,
safety wire KO 0.5 GOST 792-67. 
red enamel ХВ-124 GOST 10100-6

Time Rate

1.5 hours