Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 3

DESIGN OF SEWERAGE TREATMENT PLANT PRE ANOXIEC MBBR

NAME OF WORK :- CONSTRUCTION OF PROPOSED SEWERAGE TREATMENT PLANT


75 KLD AT ………………

PRE - ANOXIEC MOVING BED BIO REACTOR

Capacity: Average Flow 0.08 MLD

S No Description of Parameter Value Unit Reference

Quantity of Sewage Generated 75000.00 Lpd


0.08 MLD
75.00 Cum/day

Raw Sewage Characteristics


1 Average Sewage flow entering the treatment plant 75000.00 lpd
Assumed Peak Factor 3.00
2 Peak Sewage flow entering the treatment plant 225000.00 lpd
3 COD 350.00 mg/Lt
4 BOD 250.00 mg/Lt
5 TDS 100.00 mg/Lt
6 TSS 375.00 mg/Lt
7 pH 5.5 - 9.0 As Per Guide Lines

1 ANOXIC TANK
As Per Metclaff & Eddy
Waste water Characteristices
COD 350.00 mg/Lt
BOD 250.00 mg/Lt
TDS 100.00 mg/Lt
TSS 375.00 mg/Lt
pH 5.5 - 9.0 As Per Guide Lines
Rb COD 80.00
NOX 28.30
TP 6.00
Alkalinity 140 as CACO3
Dixolved Oxyzen 0.20 mg/l

Design Conditions
Influent Flow rate 900.00 cum/day
Temperature 15.00
MLSS 4500.00 g/cum
MLVSS 3000.00 g/cum
Aerobic SRT 12.50
Aeration basin volume
Mixing Energy 10.00 kw/cum
RAS ratio 0.60
Ra 255.00 kg/h

Active Bio mass equation as per Metclaff & Eddy

Xb 2049.59 g/cum

Aerobic tank No3 , N


IR ratio 1.0- R concentration
3.12
The Amount of NO3-N fed for Anoxic Tank 3720.00 Cum/day

NO3 feed 22320.00 g/day

Anoxic Volume of tank


Detention time 2.50 h

t 0.104 d

7.81 Cum

g/day Hence ok as per SDNR


F/Mb 1.17 using the curve ratio 0-2
Fraction of rb COD 0.13

13.33 Percent

Temperature Correction 0.22(1.026)^15-20


0.19 g/g d

Amount of NO2 , N that can be removed 29744.99

Oxygen requiered

Oxyzen Credit 63.78 kg/d

2.66 kg/h

Net Oxyzen Requiered 252.34 kg/h

Anoxic Zone Mixing Energy 10.00 kw/cum

Volume 7.81

Power 0.08 KW

Size Of Anoxic Tank required 7.81 Cum

Depth 2.50 m

Area 3.13 Sqm

Width 3.20 m

Length 2.50 m

Free board 0.30 m

Width Provided 3.20 m

Length Provided 2.50 m

Volume Provided 20.00 CUM

Mixing power for Anoxic Zone 3 watt/m2 -8 watt/m2 ( Metclaf& Eddy, Fifth Edition , Vol , pg=
(proposed mixing intensity at Anoxic zone for complete mixing)

Minimum power selection 5.00 Watt/m³

The selection of mixer shall also refering to the thrust which refering to the geometry of the tank.

Hence, Minimum mixing power for Anoxic Zone


= 100 W
= 0.1 kW

Mixing power from selected submersible mixer


= 0.1 kW (min)

You might also like