Project Title: DXN-ZONE 7

Date: 8/5/003
Note:
Steel Density = 7850kg/m^3 fy= 410 N/mm^2
Load factor= 1.5
Column Reference C1 F/8
Assume beam depth = 900 mm

Level PCAP-GF GF-INT. INT.-L1 LI-L2 L2-RF RF-UP.RF


Load 497.00 157.00 432.00 472.00 296.00 0.00
Total Load 1854.00 1357.00 1200.00 768.00 296.00 0.00
Total Height(m) 1500.00 4500.00 4500.00 4600.00 4600.00 3000.00
Lex/h<15 1.00 6.00 6.00 7.40 7.40 4.20
Ley/b<15 2.00 12.00 12.00 12.33 12.33 7.00
b(width)-mm 300.00 300.00 300.00 300.00 300.00 300.00
h(length)-mm 600.00 600.00 600.00 500.00 500.00 500.00
Asc 180000.00 180000.00 180000.00 150000.00 150000.00 150000.00
fcu-N/mm^2 25.00 30.00 30.00 30.00 30.00 30.00
Dia. Bar-mm 25.00 16.00 16.00 12.00 12.00 12.00
Nos bar 6.00 8.00 6.00 4.00 4.00 4.00
Ast-mm^2 2945.63 1608.70 1206.53 452.45 452.45 452.45
r%(1<r<4) 1.64 0.89 0.67 0.30 0.30 0.30
Pu-kNx1.5 2781.00 2035.50 1800.00 1152.00 444.00 0.00
Nu -kN 2384.16 2331.91 2221.43 1699.29 1699.29 1699.29
Nu (>Pu)-kN 0.00 1.00 1.00 1.00 1.00 1.00
% of Nu>Pu -14.27 14.56 23.41 47.51 282.72 #DIV/0!
Col dia (if round)-mm 478.85 478.85 478.85 437.13 437.13 437.13
COLUMN B1 FLR 1 FLR 2 FLR 3 FLR 4 FLR5 FLR6-18 ROOF
C1 381 5715
C2 458 6870
C3 263 3945
C4 0
C5 500 7500
C6 444 6660
C7 1168 17520
C8 350 5250
C9 328 4920
C10 844 12660
C11 293 4395
C12 169 2535
C13 687 10305
C14 110 1650
C15 170 2550
C16 510 7650
C17 242 3630
C18 400 6000
C19 260 3900
C20 490 7350
C21 110 1650
C22 720 10800
CB1 150 100
CB2 300 265
CB3 545 295
CB4 475 800
CB5 920 735
CB6 1040 860
CB7 565 480
CB8 1120 900
CB9 570 480
CB10 1000 915
CB11 675 445
CB12 425 350
CB13 525 445
CB14 1150 1110
CB15 300 250
CB16 300 275