QUANTITATIVE CORONARY ANALYSIS &

QUANTITATIVE VESSEL ANALYSIS SOFTWARE


Product Data
No. MPDXR0206EA XIDF-QCA804
APPLICATION
XIDF-QCA804 is a QCA (quantitative coronary analysis) and QVA (quantitative vessel analysis) software package for use in
clinical practice and research.
On-line QCA can be applied to an acquired image during coronary diagnosis and PCI. This software features automatic con-
tour detection of the artery of interest and analysis of its dimensions.
In addition, this on-line QVA software is intended for quantitative analysis of blood vessels such as the aorta, iliac arteries,
renal arteries, etc.
QVA supports automatic contour detection for vessels up to 50 mm in diameter.

FEATURES
• Automatic contour detection is supported for QCA and QVA.
• Various calibration methods such as catheter calibration, sphere calibration, and distance calibration are available.
• Results of QCA and QVA can be stored in the DFP-8000D as photo images and can be displayed in the examination room
as a reference image.
• Calibration, QCA, and QVA can be performed at the tableside.

COMPOSITION
• Documentation ............................................................1 set
• License key ..................................................................1 set

COMPATIBLE SYSTEMS
• InfinixTM -i series (DFP-8000D)*
* XIDF-QCA804 cannot be used in combination with XIDF-QCA801, XIDF-QCA802, or XIDF-QCA803.
XIDF-QCA804
OPERATION IN CURRENT CASE MODE/POSTPROCESS MODE
Quantitative Coronary Analysis
• Image selection
• Calibration
– Catheter calibration
– Sphere calibration
– Distance calibration
– Copy calibration (use last calibration)

• Analysis
– Arterial contour detection

2
• Manual correction and restriction
– If the detected contour for the arterial segment is not satisfactory, the contour can be corrected manually using the cor-
rection function and the restriction function.
• Reports
– After analysis, results and a graphic window are displayed on the analyzed image.
Analysis method: Auto/User/Subsegment
Graphic window: Diameter/Area/Background/Profile
– When the [Exit] button is pressed, several report pages are saved as a photo image to the DFP-8000D.

3
MPDXR0206EA

Quantitative Vessel Analysis


• Image selection
• Calibration
– Catheter calibration
– Sphere calibration
– Distance calibration
– Copy calibration (use last calibration)
• Analysis (Analysis of subtracted images is also supported.)
– Arterial contour detection

• Manual correction and restriction


– If the detected contour for the arterial segment is not satisfactory, the contour can be corrected manually using the cor-
rection function and the restriction function.
• Reports
– After analysis, results and a graphic window are displayed on the analyzed image.
Analysis method: Auto/User/Subsegment
Graphic window: Diameter/Area/Background/Profile
– When the [Exit] button is pressed, several report pages are saved as a photo image to the DFP-8000D.

TABLESIDE OPERATION
Quantitative Coronary Analysis
• Image selection
• Calibration
– Catheter calibration
– Sphere calibration
– Distance calibration
– Copy calibration (use last calibration)

4
MPDXR0206EA

• Analysis
– Arterial contour detection

• Manual correction and restriction


– If the detected contour for the arterial segment is not satisfactory, the contour can be corrected manually using the cor-
rection function and the restriction function.
• Reports
– After analysis, results and a graphic window are displayed on the analyzed image.
– When the [OK] button is pressed, several report pages are saved as a photo image to the DFP-8000D.

Quantitative Vessel Analysis


• Image selection
• Calibration
– Catheter calibration
– Sphere calibration
– Distance calibration
– Copy calibration (use last calibration)
• Analysis (Analysis of subtracted images is also supported.)
– Arterial contour detection
• Manual correction and restriction
– If the detected contour for the arterial segment is not satisfactory, the contour can be corrected manually using the cor-
rection function and the restriction function.
• Reports
– After analysis, results and a graphic window are displayed on the analyzed image.
– When the [OK] button is pressed, several report pages are saved as a photo image to the DFP-8000D.

CUSTOMIZATION
• Customization of some parameters for QCA, QVA, and calibration is possible in Utility Mode of the DFP-8000D.

5
XIDF-QCA804 MPDXR0206EA

TOSHIBA MEDICAL SYSTEMS CORPORATION

http://www.toshibamedicalsystems.com
©Toshiba Medical Systems Corporation 2005 all rights reserved.
Design and specifications subject to change without notice.
2005-06 TME/KI
Infinix is a trademark of Toshiba Medical Systems Corporation. Toshiba Medical Systems Corporation meets Toshiba Medical Systems Corporation Nasu operations meets
internationally recognized standards for Quality the Environmental Management System standard, ISO 14001.
"Made for Life" is a trademark of Toshiba Medical Systems Corporation. Management System ISO 9001, ISO 13485.
Printed in Japan

You might also like