PROJECT PROPOSED

: BITUMEN EXPORT FACILITY BLDG.


LOCATION PILILLA,
: RIZAL
DESIGNED BY RER:
DATE ########
:
FOOTING DESIGNATIONCF-1:

COMBINED FOOTING DESIGN


Max. Allowable Soil Pressure
= 150.0 KPa
fy = 227 MPa
f'c = 20.68 MPa

EXTERIOR COLUMN INTERIOR COLUMN TOTAL


DEAD LOAD = 247.25 KN 744.25 KN 991.5 KN
LIVE LOAD = 67.708 KN 176.04 KN 243.748 KN
EARTHQUAKE LOAD= -228.68 KN 228.68 KN 0 KN

315 KN 920 KN 1,235 KN


COLUMN DIMENSIONS
b 500 mm 500 mm
t 500 mm 500 mm

CENTER TO CENTER DISTANCE BETWEEN EXTERIOR & INTERIOR


= 4,000COLUMN
mm
DISTANCE BET. THE EXTERIOR COLUMN OUTER FACE &=FOOTING0EDGE
mm

MAXIMUM SHEAR = 655 KN


MAXIMUM MOMENT = 598 KNm

REQUIRED FOOTING DIMENSIONS


WEIGHT (KN) WIDTH (m) LENGTH (m) THICKNESS(m)
141.31 1.40 6.46 0.65

AREA OF REINFORCEMENT REQUIRED

LONGITUDINAL (Top) = 5,422 mm² REBAR = 20 mm Ø


LONGITUDINAL (bottom) = 5,422 mm²
ANSVERSE (Ext. Column) = 3,106 mm²
RANSVERSE (Int. Column) = 4,531 mm²

Note : Transverse reinforcement is distributed to a width equal to


COLUMN WIDTH PLUS 0.75 * (thickness - 0.10 ) ON EACH SIDE OF COLUMN

1.40 m

6.46 m

º º º º º º º º º º 0.65 m