Professional Documents
Culture Documents
DLRO600: Digital Microhmmeter
DLRO600: Digital Microhmmeter
Digital Microhmmeter
DLRO600
Digital Microhmmeter
When you move to the next joint DLRO detects the new completed Test Current Range: 10 A to 600 A unsmoothed d.c. in
circuit automatically and carries out the next test, and so on until all 1 A steps
joints have been tested. The results may be stored automatically and
Accuracy: ±2% ±2 A
may be recalled to the display or downloaded for review.
Voltmeter input
impedance: >200 kΩ
Hum rejection: 5 V rms 50 Hz/60 Hz
SPECIFICATIONS
Operation Temperature: -10 to +50ºC
Measurement:
Storage Temperature: -25 to +65ºC
Range: 0.1 µΩ to 999.9 mΩ
Calibration: 20ºC
(Subject to supply voltage and leads used)
Co-efficient: <0.05% per ºC
Accuracy: Voltage ±0.5% ± 0.1 mV
Max. Humidity: 95% RH non-condensing
Current ±0.5% ± 0.1 A
Maxi Altitude: 2000 m
Resistance: Better than 1% from
Safety: IEC61010-1
100 µΩ to 100 mΩ
EMC: IEC61326-1
700 Dimensions: 410 x 250 x 270 mm
600 Weight: 14.5 kg (excluding test leads)
4 mΩ
500 Load
400
7 mΩ
300 Load
200
100
0
100 120 140 160 180 200 220 240
Output Current:
The chart above shows the maximum output current available
at different supply voltages with a 4 mΩ load (i.e. standard 5 m
current leads only) and with a 7 mΩ load
Current Lead Resistance (Megger supplied leads)
2 x 5 m 50 mm2 current leads 4 mΩ
2 x 10 m 70 mm2 current leads 5.4 mΩ
2 x 15 m 95 mm2 current leads 6 mΩ
Maximum Continuous Test Time
More than 60 seconds at 600 A
@ 20ºC ambient.
Power Supply for: See chart. full output:
207 to 265 V 50/60 Hz with a load
less than 7 mΩ including current leads
reduced output: Down to 100 V 50/60 Hz.
Test Modes: Manual, Auto, Continuous.
Test Time: 7 seconds NORMAL /AUTO mode.
Refreshed every 2 seconds in
CONTINUOUS mode
Display: Large, high resolution backlit liquid
crystal display
Warnings Current flowing: - LED. Other
warnings are shown on the lcd display.
Data Transfer Real time or batch download via
RS232 using Download Manager.
Storage Capacity: 300 result sets and memo,
battery backed for 10 years.
Memo field: 200 characters max.
2
DLRO600
Digital Microhmmeter
ORDERING INFORMATION
STANDARD VERSIONS WITH TEST LEADS VERSIONS WITHOUT TEST LEADS
DESCRIPTION
Lead set consists of pair of flexible high current capacity leads, together with a separate pair of lightweight
potential leads.
Current leads are fitted with heavy duty sprung clamps (60 mm jaw capacity).
Potential leads fitted with smaller HD crocodile clips 22 mm jaw capacity).
Note:
6220-755 supplied as standard with DLRO600-EN and DLRO600-FR
DESCRIPTION
Lead set consists of pair of flexible high current capacity (600 A cont.) leads, together with a separate pair of lightweight potential leads.
Current leads are fitted with heavy duty sprung clamps (60 mm jaw capacity).
Potential leads fitted with smaller HD crocodile clips 22 mm jaw capacity).