Download as pdf or txt
Download as pdf or txt
You are on page 1of 19

压缩空气净化设备 冷冻式干燥机

Compressed Air Purification Equipment


Refrigeration Dryer

使用说明书
Operation Manual

建德市嘉源净化设备有限公司
Jiayuan purification equipment Co., Ltd.Jiande
1
目录
Directory
1. 产品概述和注意事项
1. Product Overview and Notes
2. 冷干机系统流程图
2. Cold and dry system flow chart
3. 冷干机的使用要求
3. Requirements for use in cold and dry
4. 冷干机的安装
4. Cold and dry installation
5. 冷干机的操作注意事项
5. Cold and dry handling precautions
6. 冷冻式干燥机的调试
6. Debug of Refrigeration Dryer
7. 冷冻式干燥机的日常维护要点
7. Main Points for Daily Maintenance of Refrigeration Dryer
8. 冷冻式干燥机的故障分析与排除
8. Fault Analysis and Troubleshooting of Refrigeration Dryer
9.压缩空气净化设备的系统流程图
9. System flow chart of Compressed Air Purification Equipment
10.JYH-75FC 冷干机关键元器件明细表
10.JYH-75FC cold and dry list of critical components
11. 电气原理图
11. Electrical Schematic Diagram
12.JYH-75FC 冷干机备品备件清单
12.JYH-75FC cold and dry machine spare parts list
13.气冷式冷干机工艺流程图
13.Air-cooled cold and dry flow chart
14.气冷式冷干机构造图解
14.Air-cooled cold and dry machine construction diagrams

2
欢迎使用嘉源系列净化设备
Welcome Your Use of Jiayuan Series of Purification Equipment
感谢您使用嘉源系列产品,在使用前,请您务必仔细阅读使用说明书,为您的使用提供方
便。
Thank you for using Jiayuan series of products. Please be sure to read the operation manual
before use, to provide convenience for your use.
使用本机之前,请遵守如下规定:
Before using this unit, please observe the following provisions:
1:压缩空气压力不得超过干燥机容许使用最高压力(铭牌标示)。
1: Air pressure must not exceed the maximum pressure allows the use of the dryer (nameplate).
2:维修或拆装前:必须确保系统内没有压力。
2: Repair or disassembly before: we must ensure that there is no pressure.
3:操作电源必须符合机器上的铭牌标示。
3: Operating power supply must conform to what is shown on nameplate on the machine.
4:维修前必须切断本机电源供给以保证安全。
4: Before maintenance, be sure to cut off the power supply of the dryer to ensure safety.
5:维修时必须遵守厂方规定的公共安全守则。
5: Maintenance must comply with the public safety regulations prescribed by the manufacturer.
若未按本手册操作及做一般性保养,本公司不负保固责任。
The company will not assume any warranty responsibility if operations and general
maintenance are not carried out according to the manual.
一、产品概述
Product Overview
压缩空气冷冻式干燥机(以下简称冷干机)是压缩空气的净化设备。本机是引进国际先进
水平的机型经过改进设计而成的。经本冷干机处理后的压缩空气,干燥度可达到压力露点 2-10
℃(0.7MPa)相当于常压露点-23℃~-17℃左右。除水率可达 93%,含油量不超过 5PPM。若配用
本公司高精度压缩空气过滤器则可全部滤去大于 0. 01 m 的固定杂质及 99.999%的油份(参见
压缩空气精密过滤器说明书)。从而得到无水、无油、无尘的高净度压缩空气,以满足气动控
制传动、精密仪表、喷塑喷漆、食品医药、电子零件、冶金船舶、潜水呼吸等行业对压缩空气
清净度的要求。
Compressed air refrigeration dryer (hereinafter referred to as cold and dry) is compressed air
purification equipment. This machine is the introduction of international advanced level models
made through improved design. After treatment of the cold and dry compressed air, pressure dew
point dryness can reach 2-10 ℃ (0.7MPa) equivalent pressure dew point -23 ℃ ~ -17 ℃ or so.
Water removal rate of up to 93% oil content not exceeding 5PPM. If equipped with the company
precision compressed air filter can filter out all greater than 0. 01 m fixed impurities and 99.999% of
3
the oil (see manual precision filter compressed air). Resulting in dry, oil-free, dust-free compressed
air high clarity to satisfy pneumatic control drive, precision instrument, spray paint, food,
pharmaceuticals, electronic parts, metallurgical vessel, diving breathing compressed air industry
cleanliness requirements .
二.冷干机是运用先进的制冷技术,对压缩空气进行降温,使其中含有的大量水蒸气、油
雾凝结成液滴由排水器排出机外,从而得到干澡纯净的压缩空气。嘉源冷干机采用国际名牌冷
媒压缩机,以及其它进口高品质的关键元器件,运转平稳、性能可靠,噪音低、寿命长、连续
运作平均无故障时间可达一万小时以上。
The refrigeration dryer cools the compressed air with the use of advanced refrigeration
technology, which makes a large quantity of water vapor and oil mist contained in the compressed
air condense into droplets and be discharged outside the machine by a water drainer, thus getting dry
and pure compressed air. Jiayuan refrigeration dryers use refrigerant compressors of the international
brands, as well as other imported high-quality key components, with advantages of smooth operation,
reliable performance, low noise, long service life and continuous operation, and their mean time
between failures is up to more than ten thousand hours.

二、冷冻式干燥机系统流程图
Refrigeration dryer system flow chart
(该流程图仅供使用者参考,本公司保留修改权利,并不另行通知)
(The flowchart is for user reference, and the company reserves the right to modify it, without any
prior notice)
1.制冷压缩机
1. Refrigerant compressor
2.制冷剂热交换器
2. Refrigerant heat exchanger
3. 风冷冷凝器
3 Air-cooled condenser
4. 水冷式冷凝器
4. Water-cooled condenser
5. 修理阀
5. Service valve
6. 灌充阀
6. Filling valve
7. 干燥过滤器
7. Drier-filter
8. 电磁阀
8. Solenoid valve
9. 冷媒视窗
9. Refrigerant window
10. 膨胀阀
10. Expansion valve

4
11. 毛细管
11. Capillary
12. 热气旁路阀
12. Hot- gas by-pass valve
13. 蒸发器
13. Evaporator
14. 气水分离器
14. Gas-water separator
15. 空气热交换器
15. Air heat exchanger
16. 液气分离器
16. Liquid-gas separator
17. 气冷式前置冷却器
17. Air-cooled pre-cooler
18. 水冷式前置冷却器
18 Water-cooled pre-cooler
19. 高压跳脱保护开关
19. High-pressure trip protection switch
20. 压力控制开关
20. Pressure control switch
21. 自动排水器
21. Automatic water drainer
22. 冷却水过滤器
22. Cooling water filter
23. 水量调节阀
23. Water regulating valve
24. 过高压安全释荷阀
24. Over- high pressure safety unloading valve
25. 空气入口压力表
25. Air inlet pressure gauge
26. 空气出口压力表
26 Air outlet pressure gauge
27. 冷媒低压表
27 Refrigerant low pressure gauge
28. 冷媒高压表
28. Refrigerant high pressure gauge

三.冷干机的使用要求
Operation Requirements of Refrigeration Dryer
1、选择相应的压缩空气后部冷却器、储气罐及过滤器与冷干机。其中,后冷、储气罐是
必备的,且须安装在空压机与冷干机之间。过滤器 C 级应配置,其余可据需要考虑。
1. Select the corresponding rear compressed air cooler, air tank and filter, and refrigeration

5
dryer. Among them, the rear cooler and the air tank are requisite, and must be installed between the
air compressor and the refrigeration dryer. The filter should be configured to be C-class, and the
remaining data can be configured according to needs.
2、使用工况:
2. Operating conditions:
环境温度:≤60℃
Ambient temperature: ≤60℃
进气温度:普通型≤45℃;高温型≤80℃
Inlet temperature: Normal ≤ 45 ℃; high temperature ≤ 80 ℃
进气压力 0.2Mpa~1.0Mpa(超过 1.0Mpa 可接受订货)
Inlet pressure 0.2Mpa ~ 1.0Mpa (more than 1.0Mpa orders accepted)
装机环境:通风良好且无尘埃之场所
Installation environment: in a well-ventilated and dust-free place
四、冷干机的安装
Installation of Refrigeration Dryer
l、水平放置在水泥地面即可(400W 以上机型可加地脚螺栓)。
l. Place it horizontally on the concrete floor (anchor bolts can be fixed on the machine type with
a capacity of more than 400W).
2、从空压机出口到冷干机入口的管道要作防锈处理,不得有造成蓄水的管送弯曲。
2. Rust-proof treatment shall be carried out to the pipeline between the outlet of the air
compressor and the inlet of the refrigeration dryer, and the pipe bend storing water shall be avoided.
3、与周围设备、墙壁保持 1 米以上的距离,以利于操作、检修和日常维护。风冷式保持
通风畅通、水冷式保证进水压力大于出水压力 0.2Mpa 以上,流量与所配置的水管的直径相符,
进水温度不超过 35℃水质要求干净无杂质(宜在进水口处进行过滤)。
3. Maintain a distance of more than one meter away from the surrounding equipment and walls,
so as to facilitate the operation, overhauling, and daily maintenance. The air-cooled type shall be
kept ventilated and unimpeded, and for the water-cooled type, its water intake pressure must be
greater than the water outlet pressure by 0.2Mpa and above, its flow shall match with the diameter of
the configured water pipe, the water intake temperature does not exceed 35℃, and water quality
shall be clean and free of impurities (the water should be filtered in the water inlet).
4、冷干机是制冷设备,装卸、搬运、安装时应避免较强的震动及较大角度的倾斜。
4. The refrigeration dryer is refrigeration equipment, so strong vibrations and large-angle tilt
shall be avoided during loading and unloading, transporting, and installation.
5、在冷干机进出口管道上要加装修理阀与旁路阀,如图。
5. Service valves and by-pass valves shall be installed on the inlet and outlet pipes of the
refrigeration dryer, as shown in the figure.
6、装在活塞式空压机后面,为防止震动、脉冲,需在前面安装缓冲储气罐。
6. It is installed behind the piston-type air compressor, and in order to prevent vibration and
impulse, a buffer air tank need to be installed in front of it.
7、在安装自动排水器时,请不要把排水器进口边的小螺钉碰断。
7. While installing the automatic water drainer, do not break the small screws at the side of the
inlet of the water drainer.

6
9、电气安装
9. Electrical Installation
A、专线-单独设置一个电源开关,不要与其它设备共用一个启动电源。
A. A special line shall be equipped with a separate power switch, so as not to share the same
startup power supply with other devices.
B、电压波动在±5%以内。
B. Voltage fluctuations shall be within ± 5%.
C、配置电缆应避免截面过小或太长,以免引起电压降。
C. Cross-sections of the configured cables should not be too small or too long, so as not to
cause a voltage drop.
D、电源侧安装一套电器;如磁力起动器、空气开关(或闸刀),熔断丝等。
D. Install a set of electrical appliances at the side of the power supply, such as a magnetic starter,
an air switch (or knife switch), and fuse wires.
E、正确接地。
E. Properly grounded.

五、冷干机操作注意事项
Operation Notes of Refrigeration Dryer
1、检查第三项工况情况是否符合使用要求。
1. Check whether the working conditions in the Item III above meet the operation requirements.
2、检查电源:电压及相数是否符合规定,电气接线是否正确。
2. Check the power supply: to see whether the voltage and phase number meet the requirements,
and the electrical wiring is correct or not.
3、风冷式:冷凝器通风道是否畅通。

7
3. The air-cooled type: the airway of the condenser is smooth or not.
4、冷干机前后配置的过滤器是否安装正确。
4. The filters configured before and after the refrigeration dryer is installed correctly or not.
5、旁路阀及进口修理阀是否关闭,出口修理阀是否打开。
5. The bypass valve and inlet service valve are closed or not, and the outlet service valve is
open or not.
6、自动排水器球阀是否打开。
6. The ball valve of the automatic water drainer is open or not.
7、有冷媒压力表的机型,观察表的静态指示值是否正常;在正常情况下有高低压表的冷
干机两表静态指示值应近似相等。
7. For the machine type with a refrigerant pressure gauge, observe whether the static indicated
value of the gauge is normal; under normal circumstances, both the static indicated values of the
refrigeration dryer with high and low pressure gauges should be approximately equal.
8、有时间继电器的机型,有否设定延时启动时间值(一般应延时 2~3 分钟)。
8. For the machine type with a time relay, to see whether a delay start time value has been set
(the delay time generally should be 2 to 3 minutes).
9、管道中残存之空气有否放掉。
9. To see whether the remaining air in the pipe has been let go.
以上检查无误后,方可启动冷媒压缩机,注意倾听压缩机运行是否平稳、无杂音、并观察:
高压冷媒表指示是否上升,低压冷媒表指示是否下降(无表,可用手触摸冷压缩机排气管温度
是否太高于吸气管温度)
You cannot start the refrigerant compressor until the above checks are correct, and listen
attentively to see whether the compressor is running smoothly without noise, and observe: whether
the indicated value of the high-pressure refrigerant gauge rises and the indicated value of the
low-pressure refrigerant gauge declines (if there are no gauges, judge whether the exhaust pipe
temperature is much higher than the air suction pipe temperature by touching the exhaust pipe and
the air suction pipe of the refrigerant compressor.
风冷式,观察风扇是否能自动启动或停止:
For the air-cooled type, observe whether the fan can automatically start or stop:
冷凝风扇:风扇启(低压:0.44Mpa 或高压 1.6Mpa)
For condensation fan: when the fan is on (low pressure: 0.44Mpa, or high pressure: 1.6Mpa)
风扇关(低压:0.4Mpa 或高压 1.4Mpa)
When the fan is off (low pressure: 0.4Mpa, or high pressure: 1.4Mpa)

另外,严禁频繁启闭冷媒压缩机,以免烧坏压缩机电机。
In addition, frequent starting and stopping of the refrigerant compressor is also prohibited, so
as not to burn out the compressor motor.
10、关机顺序:先关闭空压机及进口修理阀,然后再关闭冷干机。
10. Shutdown sequence: firstly, turn off the air compressor and inlet service valve, then turn off
the refrigeration dryer.

8
六、冷干机的调试
Debug of Refrigeration Dryer
本公司冷干机在出厂前均经过调试运行,一般情况下,120F(W)以下机型用户可按说明书
安装操作要求直按开机使用。150F(W)以上机型用户安装完毕应原则上由本公司派人参加现场
调试。冷干机的操作人员应事前参加本公司举办的操作培训。在使用过程中如发现异常情况应
与本公司取得联系。在本公司人员指导下对某些阀件进行调整,切忌盲目操作以免损坏机件。
The company’s refrigeration dryers have been debugged for running in the factory. Under
normal circumstances, for the machine types of 120F (W) and below, users can directly start them up
for use according to the installation and operating requirements in the manual; for those of 150F (W)
and above, upon completion of installation by users, in principle, personnel should be sent to
participate in on-site debugging by the company. Operators of the refrigeration dryers should
participate in the operation training held by the company in advance. If any abnormal situation is
found in the course of use, get in touch with the company. Adjustments on certain valves shall be
carried out under the guidance of the personnel of the company, so as avoid damages to the parts due
to blind operations.
七、冷干机的日常维护要点
Main Points for Daily Maintenance of Refrigeration Dryer
1、风冷式冷凝器要经常清扫灰尘、杂物,以免堵塞影响散热效果。方法一:用压缩空气
喷吹;方法二:用皮老虎吹;方法三:用软钢丝刷或毛刷轻轻刷。(如图 1)
1. Air-cooled condenser shall be often cleaned to remove dust and sundries, so as to avoid
blockage affecting the cooling effect. Method 1: blowing it with compressed air; Method 2: blowing
it with bellows; Method 3: gently brushing it with a soft wire brush or hairbrush. (Figure 1)

9
一. 干燥机冷凝机组清法
Clearing Method for the Dryer Condensing Unit
二.自动排水器分解图
Exploded View of Automatic Drainer
三. 水过滤器分解图
Exploded View of Water Filter
1、自动排水器是本机易损部件,需经常清洗维护,以免堵塞而失去排水作用。如发生不
排水,应立即检查排水器是否堵塞,并及时按图三方法拍手拆卸清洗。
1 . The automatic drainer, a vulnerable part of the dryer, needs regular cleaning and
maintenance, to avoid loss of drainage role due to blockage. In the event of drainage failure,
immediately check whether the drainer is blocked, and timely disassemble and clean it with hand in
accordance with the method in Figure 3.
如无自动排水器(或排水器已坏),可采用手动排水,一定要及时排水,以免空气带水。
If there is no automatic drainer (or the drainer is broken), manual drain can be used, and
drainage must be carried out timely, so as to avoid mixture of air with water.
2、注意三相电不要缺相运行。
2、Pay attention to the three-phase power, and don’t run it with the lack of any phase.
3、注意倾听压缩机运行是否平稳,无杂音。
3. Listen attentively to see whether the compressor is running smoothly without noise.
4、注意手摸空气进出口有否温差。
4. Pay attention to whether there is a temperature difference between the air inlet and outlet by
touching them with hands.
5、外箱板经常擦抹灰尘。
5. Wipe dust for the outer boxboard frequently.
八、冷干机故障之分析排除
Fault Analysis and Troubleshooting of Refrigeration Dryer
冷冻式空气干燥机本身故障及外部因素所产生之故障情形不外乎下列六大因素:
Faults of the refrigeration dryer’ own and arising from external factors are nothing more than
the following six factors:
1. 压力降太大
1. Too-large Pressure Drop
状态 原因 故障排除
State Cause(s) Troubleshooting
配管系统错误 管路阀门未全开 将阀门全开
Piping System The pipe valve is not fully open To fully open the valve
Error 管径太小 管径加大
The pipe diameter is too small To increase the pipe diameter
管路太长,弯头、接头太多 管路系统重新设计
The pipeline is too long, with too many elbows and To redesign the pipeline system
joints
两台以上空压机并联运转匹配不良 管路系统重新设计
Poor parallel operation and matching of two or more To redesign the pipeline system
air compressors
管路中的过滤器阻塞 过滤器清洗或换新
The filter in the pipeline is blocked To clean the filter or replace it
10
管路连接处漏气太多 检查弯头接头
Too much air leakage in the joints of the pipeline To check the elbows and joints
空气处理量超 超过冷冻式空气干燥机额定流量压力自然降低 1.更换容量≥空压机流量的冷冻式空气干燥机
过额定值 Air Treatment exceeds rated flow of air dryer , which 1. replace a higher power air dryer, which means the air
Amount of Air will cause the pressure decreased compressor and the air dryer should fit well
Treatment 2. 减低空气流量
Exceeding the 2. To reduce the air flow
Rated Value
蒸发器内凝结 温度开关或压力开关不良 换新、检查线路、校正开关
水冻结 Poor temperature switch or pressure switch To replace it with a new one, check the line, and adjust
Freezing of the switch
Condensed 膨胀阀、热气旁路阀故障 换新、检查管路是否阻塞、校正开关
Water in the Expansion valve and hot-gas by-pass valve fault To replace it with a new one, check whether the pipeline
Evaporator is blocked, and adjust the switch
排水器不良或电磁排水阀故障 清洗或换新
The drainer is poor, or the electromagnetic drain valve To clean it or replace it with a new one
fault

2. 冷干机除水情形不良
2. Poor Water Removal of the Refrigeration Dryer
状态 原因 故障排除
State Cause(s) Troubleshooting
配管系统异常 旁路阀没有全关闭 关闭旁路阀
Abnormalities By-pass valve is not fully closed To close the by-pass valve
of 空气没有通过干燥机 干燥机入口阀门全开
Piping System Air doesn’t pass through the dryer To fully open the inlet valve of the dryer
无储气罐或储气罐装在冷干机后 储气罐按要求装置
No air tank, or the air tank is installed behind the To install the air tank in accordance with the requirements
refrigeration dryer
干燥机倾斜 地面不平整或放置平台倾斜,修正地面于水平, 将平
Dryer tilt 台调整于水平
Uneven ground or placing platform
tilt correction, ground on the level, will be adjusted on
the horizontal platform
自动排水器倾斜 将自动排水器安装于垂直状态
The automatic drainer is tilted Make it vertical
排水管路高于自动排水器 排水管路重新安装至水平状态
Drain line is higher than the automatic drainer Drainage pipeline to reinstall to the level condition
空气流量大 超过冷冻式空气干燥机额定流量压力自然降低 1.更换容量≥空压机流量的冷冻式空气干燥机
Large Air Flow Air Treatment exceeds rated flow of air dryer , which 1. replace a higher power air dryer, which means the air
will cause the pressure decreased compressor and the air dryer should fit well
排水系统异常 排水器不良或电磁排水阀故障 清洗或换新
Abnormal The drainer is poor, or the electromagnetic drain valve To clean it or replace it with a new one
Drainage fault
System 排水器前阀未全开 请确认阀门须在全开位置
Fore valve of the drainer is not fully open Please make sure the valve must be in the fully open
position
冷媒蒸发温度 露点温度太低或太高 调整压力开关、水流开关、膨胀阀、热气旁路阀
指示异常 Dew point temperature is too low or too high To adjust the pressure switch, water flow switch,
Abnormal expansion valve, and hot-gas by-pass valve

11
indication of 环境温度及入口温度过低 没关系,可让干燥机继续使用
refrigerant The ambient temperature and inlet temperature are too It does not matter, and you can continue to use the dryer
evaporation low
temperature 入口温度过高 增设后部冷却器
The inlet temperature is too high To install an additional rear cooler
周围环境空气污浊通风不良 选择较适当位置或改善通风
The ambient air is polluted and it is poorly ventilated To choose a more appropriate location or improve
ventilation
冷媒漏、冷冻效率低 补漏、加灌冷媒
Refrigerant leakage, and low efficiency of To patch the leakage and fill refrigerant
refrigeration
3. 全部不能运转
3. No Any Operation
状态 原因 故障排除
State Cause(s) Troubleshooting
电源是否正常 保险丝熔断或开熔开关跳脱 确认电源是否有欠相短路、接地现象、并检查无熔丝开
供电 The fuse burns down, or the fuse switch trips out 关是否损坏
Power supply is To confirm whether the power supply is lack of phase or in
normal or not short circuit, and its grounding, and to check whether the
no-fuse breaker is broken
断线 找出断线处,加以检修
Disconnection To find the disconnection position and repair it
有电源但不能 电压异常 请依照铭牌上额定电压指示允许范围 5%
启动 Abnormal voltage Please provide power supply in accordance with the power
It cannot be supply shown on the nameplate, with an allowable
started up even operating voltage range of 5%
there is power 开关不良 换新
supply A poor switch To replace it with a new one
接触器不良 换新
A poor contactor To replace it with a new one
过流继电器不良 换新(请检查电磁开关及压缩机出线盒)
A poor over-current relay To replace it with a new one (Please check the solenoid
switch and the outlet box of the compressor)
高低压力开关不良 换新
A poor high and low pressure switch To replace it with a new one
起动断电器不良 换新
A poor starting breaker To replace it with a new one
电容器不良 换新
A poor capacitor To replace it with a new one
温度开关不良,流量开关不良,油压缩 换新
A poor temperature switch, a poor flow switch, and To replace them with new ones
oil compression
压缩机不良 换新
A poor compressor To replace it with a new one
开源关全部正 高低压跳脱后未复归,电磁开关过流继电器未复归 换新,找出跳脱原因后再复位
常,但不能启动 The high and low voltage switch isn’t reset after its To replace it with a new one, find out the cause for the
It cannot be tripping, and the solenoid switch over-current relay tripping, and then reset it
started up even isn’t reset
all power 压缩机不良 换新
switches are A poor compressor To replace it with a new one

12
normal 电线松落 找出电线未锁紧处,确实上紧
Wire loosening To find the position where the wire is not tightened, and
tighten it

4. 启动后不良
4. Malfunction after Startup
状态 原因 故障排除
State Cause(s) Troubleshooting
电压异常 起动不久后,电线短路,产生烧焦味道 线路及开关重新配置,找出电压异常之原因
Abnormal Shortly after the startup, the electrical wire shorts out, To reconfigure the line and switches, and identify
Voltage and generates charred flavor causes for the voltage abnormalities
高压跳脱虽有 压力开关或温度开关不良,风扇停止 开关换新
复归,还是不能 A poor pressure switch or temperature switch, and fan To replace the switch with a new one
启动 stops
It still cannot be 风扇不良 换新
started up even it A poor fan To replace it with a new one
has been reset 过载跳脱 检查电驿
after a high Overload tripping To check the relay
pressure tripping 冷凝器积垢太多 清洗
Too much fouling in the condenser To clean it
过流器电器跳 起动电驿不良 换新
脱 A poor starting relay To replace it with a new one
Over-current 电容器不良 换新
Electrical A poor capacitor To replace it with a new one
Equipment 压力开关或温度开关不良,风扇停止 换新
Tripping A poor pressure switch or temperature switch, and fan To replace it with a new one
stops
油压开关不良 换新
A poor oil pressure switch To replace it with a new one
连续启动 每次启动须隔 3 分钟以上
Consecutive startup To start it every three minutes or above
压缩机过负荷 干燥机过负荷,减少空气处理量
Compressor overload To reduce the amount of air treatment, as the dryer is over
load
干燥机入口温度或周围温度过高 增设冷却器或改善通风
The inlet temperature or ambient temperature of the To install an additional cooler or improve ventilation
dryer is too high
电驿设定电流值太低 调整电流值
Relay setting current value is too low To adjust the current value
电驿接触不良 清理或换新
Poor relay contact To clean it up or replace it with a new one
电源欠相 熔丝继电器或电源开关接触不良
The power supply is lack of phases Poor contact of fuse relay or power switch
接触器不良接点不良 清理或换新
Poor contact of contactor To clean it up or replace it with a new one
冷却水没有循环 检查冷却水
The cooling water fails to circulate To check the cooling water

5. 正常运转,但效果不佳

13
5. Normal Operation without Effective Performance
状态 原因 故障排除
State Cause(s) Troubleshooting
冷媒蒸发温度 蒸发温度表不良 换新
指示过低 A poor evaporation thermometer To replace it with a new one
Refrigerant 膨胀阀或热气旁路阀故障 换新
evaporation Expansion valve or hot-gas by-pass valve failure To replace it with a new one
temperature 冷媒漏 补漏再灌充冷媒
indication is too Refrigerant leakage To patch the leakage and then fill refrigerant
low 冷媒阻塞 更换干燥剂,重新抽真空,充灌冷媒
Refrigerant blockage To replace the desiccant, vacuumize it again, and fill
refrigerant
温度开关或扭力开关设定太低风扇不断运转 调整设定温度开关或压力控制开关
Temperature switch or torque switch is set too low, To adjust the setting temperature switch or pressure control
and the fan runs constantly switch
冷媒蒸发温度 入口温度过高 增设冷却器或更换较大型之干燥机
指示过高 The inlet temperature is too high To install an additional cooler or replace it with a larger
Refrigerant dryer
evaporation 周围温度过高 增设通风设备
temperature The ambient temperature is too high, To install additional ventilation equipment
indication is too 膨胀阀或热气旁通阀故障 换新
high Expansion valve or hot-gas by-pass valve failure To replace it with a new one
冷凝器阻塞,通风不良 清洗,改善通风设备
The condenser is blocked, and poorly ventilated To clean it, and improve the ventilation equipment
冷却水温过高,或循环不良 改善冷却水
The cooling water temperature is too high, or poor To improve the cooling water
circulation
空气处理量大,但压力低 并联加装干燥机
The amount of air treatment is large, but pressure is To install an additional dryer in parallel with it
low
冷媒压缩机进排气阀片磨损 换新
The air intake and exhaust valves of the refrigerant To replace them with new ones
compressor wear down
过负荷运转 入口温度过高(超过 55℃以上) 增设冷却器
Over-load The inlet temperature is too high (over 55℃) To install an additional cooler
Operation 空气处理量大,但压力低 并联加装干燥机
The amount of air treatment is large, but pressure is To install an additional dryer in parallel with it
low
冷媒漏 补漏再灌充
Refrigerant leakage To patch the leakage and then fill refrigerant

6. 自动排水系统不良
6. Poor Automatic Drainage System
状态 原因 故障排除
State Cause(s) Troubleshooting
使用压力在 1. 5Kg/cm 以下 自动排水器正常使用压力在 2-10kg/cm
Working pressure is below 1.5Kg/cm The normal working pressure of the automatic drainer is
2-10kg/cm
管节部份阻塞 清洗
Pipe joints are partly blocked To clean it with a new one
排水阀损伤或未全开 换新或打开阀门
14
Drain valve is damaged or not fully open To replace it with a new one or open it
排水器倾斜或破损 校正固定或换新
The drainer tilts or is damaged To adjust and fix it, or to replace it with a new one
排水器过滤部分阻塞 清洗
Filtration of the drainer is partly blocked To clean it
使用压力过高 请依据自动排水器额定压力使用
Working pressure is too high Please use it according to the rated pressure of the
automatic drainer
排水管阻塞 清洗
Drainage pipeline is blocked To clean it
蒸发器管路内生锈或污垢阻塞 使用年限超过,换新
Evaporator pipeline gets rusty or is blocked by dirt The service life is exceeded, thus it shall be replaced

九、压缩空气净化器装置
System flow chart of Compressed Air Purification Equipment

1.空气压缩机: (Air compressor) 2.储气罐: (Gas tank) 3.C 过滤器(易损件) :C-Filter


(vulnerable) 4.冷冻式干燥机: (Freezing air dryer) 5.T 过滤器(易损件):T-Filter (vulnerable)
十、JYH-75FC 冷干机关键元器件明细表
Essenrial primary device detailed of JYH-75FC freezing air dryer

M 风扇电机 P 压力开关
Fan motor Pressure switch
C 电容 COMP 压缩机
Capacitor Compressor
DL1 DL2 空气开关 KM 交流接触器
Air switch AC contactor
L1 停机指示灯 FR 热继电器
Shut-down indicator light Thermal relay
L2 过载保护指示灯 FU 熔断丝
Overload protection indicator light Fuse wire
L3 高压跳脱指示灯 XJ 相序保护器
High pressure tripping indicator light Phase sequence protector
L4 启动指示灯 SB1 停机按钮
Startup indicator light Stop button
L5 低压跳脱指示灯 SB2 启动按钮
Low pressure tripping indicator light Start button

15
十一、电气原理图
Electrical Schematic Diagram

NUMBER 1 2 3 4 5 6
SYMBLE SB1 SB2(2L) M DL P KR
NAME Stary button with Stopbutton with Fan Hest relay Pressure Heat relay
light light condenser control
switch
NUMBER 7 8 9 10
SYMBLE COMP KM KP(3HL) KR(4HL)
NAME Motor of A.C. Overload crip High pressure trip
Contactor Contactor protection protection switch
switch
NUMBER 11 12 13 14
SYMBLE L1 L2 L3 L4
NAME Stop lights Abnormal Unusual light Power Indicator
overload pressure
indicator
十二、JYH-75FC 冷干机备品备件清单
The repair piea spare part inventory of one set JYH-75FC freezing air dryer
名称 规格参数 数量 单价 生产厂商 备注
Name Specifications Quantity Unitprice Remark
C300 过滤器芯 C-300E 1 建德嘉源净化设

16
C300Filter core one 备有限公司
T300 过滤器芯 T-300E 1 Jiayuan
T300Filter core one purification
排水器 AAD400-15 3 equipment Co.,
Drainage three Ltd. Jiande
过滤器密封圈 2
Filter seals two
十三、气冷式冷干机工艺流程图
Cooling freezing air dryer flow chart

17
十四、气冷式冷干机构造图解
Cooling freezing air dryer Constructional drawing

1. Condensation pressure gauge 2.Evaporates the thermometer 3.The air outlet


thermometer 4.Button indicating lamp 5.Condensers 6.Automatic drainer 7.Refrigerant
compressor 8.Liquid-air separatlor 9.Drying filter 10.Filfer valve 11.Fan motor
12.Pressure control switch 13.High-pressure tripping protective switch 14.Evaporator
15.Air-water separator 16.Air inlet(out) 17.Filter-core18.Filter seal-enclose

18
建德市嘉源净化设备有限公司
Jiande Jiayuan Purification Equipment Co., Ltd.
地址:浙江省建德市杨村桥镇工业园区