US E & C AR E MANUAL
P OR TAB L E TY P E R OOM AIR C ONDITIONE R
MODE L #: DOC-091R
DOC-091R H
UL and C R
C UL listed US
LIS TE D
W1
CONTENTS
1.SAFETY RULES............................................................................. 1
2.NAMES OF PARTS.......................................................................... 2
3.ACCESSORIES................................................................................ 2
6.INSTALLATION............................................................................... 6
7.MAINTENANCE............................................................................... 7
8.TROUBLE SHOOTING.................................................................... 8
SAFETY RULES
1
NAMES OF PARTS
OPRATION PANEL
AIR INLET INDOOR
REAR COVER FRONT COVER
AIR OUTLET
AIR OUTLET
OUTDOOR
WATER PUMP
DRAIN HOSE AIR INLET
OUTDOOR
AIR INLET
REMOTE CONTROLLER OUTDOOR POWER CORD CONTINUOUS
DRAIN HOSE
Fig.1
ACCESSORIES
DUCT 1
WALL PLUG 4
SCREWS 4
ALKALINE BATTERIES 2
REMOTE CONTROLLER 1
Fig.2
Check all the accessories are included in the package and please refer to the installation instructions
for their usage.
2
OPERATION PANEL OF THE AIR CONDITIONER(COOLING AND HEATING)
COOL/DRY/FAN/HEAT INDICATIOR
DIGITAL DISPLAY FAN SPEED INDICATOR Green lamp will light when the mode is selected
INFRARED
SIGNAL RECEIVER POWER BUTTON
Turn on/off the unit
OPERATING PANEL
Fig.3
INFRARED
SIGNAL RECEIVER POWER BUTTON
Turn on/off the unit
OPERATING PANEL
Fig.4
3
OPERATING INSTRUCTING FOR THE AIR CONDITIONER
Before Starting This Unit
1) Select a suitable location, make sure you have easy access to an electrical outlet.
2) Install the Flexible Exhaust Hose and the Adjustable Window Slider Kit as depicted in Fig.5 &
Fig.5a
Fig.5 Fig.5a
Fig.6
1 BEFORE USE
Dehumidifying and Cooling Operations
- The operating range for cooling operating is 17OC-30OC/63OF-86OF.
- If the cooling or dehumidifying operations have been switched off and need switching on again
in a short time, allow approximately three minutes for the cooling or dehumidifying operations
to resume.
- Make sure the water pump drain hose is correctly connected to the unit.
Power supply:
- Insert the AC Power Plug to a AC socket.
- Do not connect the air conditioner to a multiple socket outlet which is also being used for other
electrical appliance.
- Be sure the power supply is AC 115V~ 60Hz.
4
O O O O
2 COOLING OPERATION (Operating temperature range: 17 C-32 C/63 F-90 F)
- Press the "MODE" button several times until the "COOL" indicator light comes on.
- Press the "TEMP SETTING" buttons " " or " " to select your desired room temperature.
(17OC-30OC/63OF-86OF)
- Press the "FAN SPEED" button to choose the fan speed.
O O O O
3 DEHUMIDIFYING OPERATION (Operating temperature range: 13 C-32 C/55 F-90 F)
- Press the "MODE" button several times until the "DRY" indicator light comes on.
- The fan will run at a fixed speed at this setting.
- Keep windows and doors closed for the best dehumidifying effect.
- Do not put the duct to window.
5
INSTALLATION
1 IMPORTANT:
Install the mobile ir conditioner in a flat and spacious location
where the air outlets will not be covered up. A minimum
clearance of 30cm from a wall or other obstacles should
be kept. The appliance shall not be used in the laundry.
The plug shall accessible after appliance is positioned. 30c
m
cm
Wiring shall be done according to National rules. 30
Fig.8
A) TEMPORARY-
1. Attach one end of the duct to the exhaust air outlet of the Adapter A
mobile air condition, first fit the left side of the duct on the Skruer
Rawlplugs
6
Window Kit Installation
Your window kit has been designed to fit most standard Horizontal
window
Vertical and horizontal window applications, However, it
may be necessary for you to improvise/modify some aspects
of the installation procedures for certain types of window.
Please refer to Fig. 11 & Fig. 11a for minimum and maximum
window openings. Window Slider Kit
Minimum:67.5cm(2.22ft).
Maxmum:123cm(4.04ft).
Fig.11a
MAINTENANCE
IMPORTANT:
1) BE SURE TO UNPLUG THE UNIT BEFORE CLEANING.
2) DO NOT USE GASOLING, THINNER OR OTHER CHEMICALS TO CLEAN THE UNIT.
3) DO NOT WASH THE UNIT DIRECTLY UNDER A TAP OR USING A HOSE. THE ELECTRICAL
CAUE DANGER.
4) IF THE POWER CORD IS DAMAGED, IT SHOULD BE REPAIRED BY MANUFACTURE OR ITS
AGENCY.
1 AIR FILTER
- Clean the air filter at least once every two weeks to
prevent inferior fan operation because of dust.
- Removal
Pull out the filter cover and remove the air filter from the
filter cover.
- Cleaning
Wash the air filter by immersing it gently in warm water
(about 40OC/104OF) with a neutral detergent. Rinse the
filter and dry it in a shady place.
- Mounting
Attach the air filter to the filter cover using the attachment
hooks on the inner surface of the cover. Put the filter cover
back to the unit.
2 UNIT ENCLOSURE
- Use a lint-free cloth soaked with neutral detergent to clean
the unit enclosure. Finished by a dry clean cloth.
Fig.12
7
TROUBLE SHOOTING
1. UNIT DOES NOT - Water full indicator blinks, water tank Dump the water in the water tank.
START WHEN is full.
PRESSING 1/0 BUTTON
- Room temperature is higher than Reset the temperature.
the set temperature.(Heating mode)
2. NOT COOL ENOUGH - The windows or doors in the room Make sure all the windows and
are not closed. doors are closed.
- There are heat sources inside the Remove the heat sources if possible.
room.
- Exhaust air duct is not connected or Connect the duct and make
blocked. sure it can function properly.
3. POWER SHUT OFF AT - The automatic over heat protection Switch on again after the unit has cool down.
HEATING MODE function. When the temperature at
the air outlet exceed 70OC/158OF,the
device will stop.
4. NOISY OR VIBRATION - The ground is not level or not flat Place the unit on a flat, level
enough. ground if possible.
8
L imited Warranty
DAE WOO E LE C T R ONIC S AME R IC A, INC . warrants the following P ortable room air-
conditioner to be free from defective material and workmans hip and agrees to remedy
any s uch defect or to furnis h a new part (at the C ompanyÕs option) in exchange for any
part of any unit of its manufacture which under normal ins tallation, us e and s ervice
dis clos ed s uch defect, provided the unit is delivered by the owner to s tore or dealer
where purchas ed or Daewoo authorized s ervice center. T o es tablis h and receive
warranty s ervice at our s tore, dealer or our authorized s ervice center, a s ales receipt
or bill of s ales is required for proof of purchas e.
T his warranty does not extend to any of our electronic products which have been
s ubjected to mis us e, neglect, accident, incorrect wiring not our own, improper
ins tallation, unauthorized modification, or to us e in violation of ins tructions furnis hed by
us , nor units which have been repaired or altered outs ide of our factory, nor to cas es
where the s erial number thereof has been removed, defaced, or changed.
T his warranty is in lieu of all warranties expres s ed or implied and no repres entative or
pers on is authorized to as s ume for us any other liability in connection with the s ales of
our electronic products .
Over the counter exchange for units that are initially defective. Initial defective is
des cribed as when the dealer opens the unit and finds that it is inoperative or an
individual cus tomer opening a new unit and finding that it is initially defective. T his unit
may be returned to the factory by the dealer for exchange. Under no circums tances
will an individual cus tomer be permitted to return defective unit directly to factory.
E xchange mus t be directly with the dealer. When this unit is returned to dealer, a copy
of the purchas e evidence s tating the date of purchas e is to be put in the individual box
for dealerÕs further control with the factory.
Note: T he warranty s ervice center lis t is cons tantly changing with the addition of our
current qualified s ervice centers . If there is inadequate or no local s ervice facility,
s ubject individual cus tomer will call DAE WOO on the toll free number