Pericoli Ventilation Pap 07 2019
FLAP
SYSTEM
Closed shutter
Exclusive
opening
Open shutter
CENTRIFUGAL
SYSTEM
Closed shutter
Conventional
opening
Open shutter
Features and advantages
Effective protection
from light and air thanks
to the gaskets, which
guarantee a perfect
closure of the blades
SK optional external
safety netting
Fixing threaded
bush (M8)
Easy opening
guards
Pre-tensioned V-belt
www.pericoli.com
Technical features
EOS / EWS 53 - test number Bess Lab: 10090; 10092; 10094; 10097; 10106; 10108
Air flow* Ventilating Ventilating
Propeller Absorbed Absorbed Specific Specific
Efficiency Efficiency
rotation power* power* power input* power input*
Model Voltage** Frequency Ratio* Ratio*
speed* 0 Pa 12 Pa 25 Pa 50 Pa (0 Pa - 0 (25 Pa - 0.10 (0 Pa - 0 (25 Pa - 0.10
(0 Pa - 0 (25 Pa - 0.10
(0 Pa - 0 inH2O) 0 inH2O 0.05 inH2O 0.10 inH2O 0.20 inH2O in H2O) inH2O) inH2O) inH2O)
inH2O) inH2O)
EOS / EWS 42 - test number Bess Lab: 12324; 12321; 12317; 12320
14.600 13.900 13.100 11.400
Δ 200 V cfm cfm cfm cfm 37 44
13,4
Δ 220-240 V 50 Hz 579 RPM 909 W 978 W W/ W/ 16,1 cfm/W
cfm/W
EOS Y 380-420 V 24.900 23.700 22.300 19.400 (1000m³/h) (1000m³/h)
42/1* m³/h m³/h m³/h m³/h
*Tested according to ANSI/AMCA 210-07 ANSI/ANSHRAE 51-07 complying with ASABE/S565 OCT 2005.
Note: All fans tested with shutter and protection net.
Single phase motors, different voltage and speed regulable motors over transformers are available on request.
Performance diagrams
cfm
0 5000 10000 15000 20000 25000
80
0,30 2100
AIR FLOW
70
POWER
0,25
60
0,20 50 1600
inH2O
EOS/EWS 53/2
Pa 40 W
0,15
EOS/EWS 53/1,5
30
EOS/EWS 53/1
0,10 1100
m3/h
cfm
0 2000 4000 6000 8000 10000 12000 14000
80
0,30
AIR FLOW
70
1100 ABSORBED POWER
0,25
60
0,20 50 900
inH2O
EOS/EWS 42/1
Pa 40 W
0,15
700 EOS/EWS 42/0,75
30
EOS/EWS 31/0,5
0,10
20 EOS/EWS 42/1 [W]
500
m3/h
H
A
Loading possibilities
Fully assembled Knock-down
version (FA) version (KD)
Model 53 42 31 53 42 31
Container 20ft 28 50 76 180 250 280
Truck 40ft 48 60 78 -- -- --
www.pericoli.com
CONE FAN
Open shutter
Closed shutter
Features and advantages
ABT Automatic
belt tensioner (optional)
Bottom panel
with practical water
discharge holes.
Security grid on
the squared cone
www.pericoli.com
Technical features
EOC 53 RS 2019 - Test number Bess Lab: 12359; 12360; 12299; 12298
Propeller Air flow Ventilating Ventilating
Absorbed Absorbed Specific Specific
rotation Efficiency Efficiency
0 Pa 12 Pa 25 Pa 50 Pa power* power* power input* power input*
Model Voltage** Frequency speed Ratio* Ratio*
(0 Pa - 0 (25 Pa - 0.10 (0 Pa - 0 (25 Pa - 0.10
(0 Pa - 0 (0 Pa - 0 (25 Pa - 0.10
0 0.05 0.10 0.20 inH2O) inH2O) inH2O) inH2O)
inH2O) inH2O) inH2O)
inH2O inH2O inH2O inH2O
*According to ASABE/S565 OCT2005 at Certifying Laboratory ANSI/AMCA 210-07 test protocol ANSI/ASHRAE 51-07.
**Single phase motors, different voltage and speed regulable motors over transformers are available on request.
Note: All fans tested with shutter and net.
A
Dimensions and loading possibilities C
B
G E H
I
L
F
Weight [kg] 98-89 D
0,30 2100
70
inH2O
EOC 53/2
Pa 40 W
0,15
EOC 53/1,5
30
EOC 53/1
0,10 1100
m3/h
BELT-DRIVEN
AIR CIRCULATION FAN
4 secure suspension
eyes included
Propeller hub in
steel with corrosion
protection
Fixing threaded
bush (M8)
Easy opening
guards
www.pericoli.com
Technical features
EOR 53 - AMCA 230-12 test number Bess Lab: C12073; C12074; C12072; C12071; C12069; C12070; C12078; C12079
Propeller rotation Absorbed Thrust Specific
Model Voltage** Frequency Thrust Air flow Air flow* Efficacy
speed power efficiency ratio power input
25.100 35.500
Δ 200 V 26,44 lbf 15,40 lbf/kW
ccfm ccfm 40,35 14,6
Δ 220-240 V 50 Hz 483 RPM 1,719 kW
42.600 60.300 W/(1000 m³/h) ccfm/W
Y 380-420 V 11,99 kgf 6,98 kgf/kW
m³/h m³/h
EOR 53/2
26.200 37.150
Δ 200 V 28,87 lbf 15,70 lbf/kW
ccfm ccfm 41,19 14,3
Δ 220-270 V 60 Hz 500 RPM 1,833 kW
44.500 63.100 W/(1000 m³/h) ccfm/W
Y 380-460 V 13,10 kgf 7,14 kgf/kW
m³/h m³/h
23.400 33.050
Δ 200 V 22,89 lbf 16,80 lbf/kW
ccfm ccfm 34,23 17,2
Δ 220-240 V 50 Hz 445 RPM 1,361 kW
39.750 56.150 W/(1000 m³/h) ccfm/W
Y 380-420 V 10,38 kgf 7,63 kgf/kW
m³/h m³/h
EOR 53/1,5
22.800 32.300
Δ 200 V 21,86 lbf 16,20 lbf/kW
ccfm ccfm 34,8 16,9
Δ 220-270 V 60 Hz 446 RPM 1,348 kW
38.700 54.850 W/(1000 m³/h) ccfm/W
Y 380-460 V 9,92 kgf 7,36 kgf/kW
m³/h m³/h
21.000 29.750
Δ 200 V 18,53 lbf 18,30 lbf/kW
ccfm ccfm 28,4 20,7
Δ 220-240 V 50 Hz 398 RPM 1,015 kW
35.700 50.550 W/(1000 m³/h) ccfm/W
Y 380-420 V 8,41 kgf 8,28 kgf/kW
m³/h m³/h
EOR 53/1
21.200 30.050
Δ 200 V 18,86 lbf 18,20 lbf/kW
ccfm ccfm 28,8 20,4
Δ 220-270 V 60 Hz 398 RPM 1,038 kW
36.000 51.050 W/(1000 m³/h) ccfm/W
Y 380-460 V 8,55 kgf 8,24 kgf/kW
m³/h m³/h
20.800 29.400
Δ 200 V 18,23 lbf 19,10 lbf/kW
ccfm ccfm 27 21,8
Δ 220-240 V 50 Hz 450 RPM 0,953 kW
35.300 49.950 W/(1000 m³/h) ccfm/W
Y 380-420 V 8,27 kgf 8,68 kgf/kW
m³/h m³/h
EOR 53/1 - 3
29.900 29.650
Δ 200 V 18,53 lbf 18,70 lbf/kW
ccfm ccfm 27,8 21,1
Δ 220-270 V 60 Hz 455 RPM 0,989 kW
W/(1000 m³/h) ccfm/W
Y 380-460 V 8,41 kgf 8,50 kgf/kW 35.500 50.350
m³/h m³/h
EOR 42 - AMCA 230-12 test number Bess Lab: C12082; C12083; C12084; C12085
15.600 22.100
Δ 200 V 16,35 lbf 17,10 lbf/kW
ccfm ccfm 36,1 16,3
Δ 220-240 V 50 Hz 584 RPM 0,957 kW
26.500 37.550 W/(1000 m³/h) ccfm/W
Y 380-420 V 7,42 kgf 7,75 kgf/kW
m³/h m³/h
EOR 42/1
16.500 23.300
Δ 200 V 18,28 lbf 15,90 lbf/kW
ccfm ccfm 41,07 14,3
Δ 220-270 V 60 Hz 608 RPM 1,15 kW
28.000 39.600 W/(1000 m³/h) ccfm/W
Y 380-460 V 8,29 kgf 7,21 kgf/kW
m³/h m³/h
13.800 19.550
Δ 200 V 12,85 lbf 17,70 lbf/kW
ccfm ccfm 30,98 19
Δ 220-240 V 50 Hz 515 RPM 0,725 kW
23.400 33.200 W/(1000 m³/h) ccfm/W
Y 380-420 V 5,83 kgf 8,04 kgf/kW
m³/h m³/h
EOR 42/0,75
14.200 20.100
Δ 200 V 13,65 lbf 18,40 lbf/kW
ccfm ccfm 30,8 19,1
Δ 220-270 V 60 Hz 524 RPM 0,743 kW
34.150 W/(1000 m³/h) ccfm/W
Y 380-460 V 6,19 kgf 8,33 kgf/kW 24.100
m³/h m³/h
Sound pressure level Lpa [dB]* 65,8 / 75,5 68,8 / 73,4 70,6
G
B C
Weight [kg]** 80-69 54-50 41-38
* Measurement surface according to UNI EN ISO 3744.
** The weight depends on choosed configuration
Truck 40ft 48 60 78
www.pericoli.com
SIMPLE AND COST EFFECTIVE
BASKET FAN
4 secure suspension
eyes included
L
Air outlet cone
L Air speed Air speed
Model
(Air speed 0,2 m/s) (2 m) (10 m)
2m 10 m
BKF 53/1 65° 23 m 5,7 m/s 2,2 m/s
α
Features
Model Sound pressure level Lpa [dB]* Weight
BKF 53/1 70,3 dB 43
a b
*Measurement surface according to UNI EN ISO 3744. pic C.7
A C
D
Dimensions Loading possibilities
Dimension - A - [mm] 1380 Fully assembled Knock-down
version (FA) version (KD)
Shutter versions
AS AETERNUM
aluminium shutter structure, propeller and shutter in AISI 304
(only for models 31 e 53)
Fan versions
STANDARD
galvanised steel
STANDARD STANDARD
galvanised steel AETERNUM galvanised steel
structure, propeller and
shutter in AISI 304
(only for models 31 e 53)
Blade versions
Motors
Accessories
FIX fixing strip for LTP light filter WPC insulating cover for
wall installation long non-working period
microcomputer
TPR TPU
magnetothermic motorstarter
modules
swich
www.pericoli.com
VERSIONS, SUPPLEMENTS AND ACCESSORIES FOR CIRCULATION FANS
Blade versions
ALU ALU
aluminium alloy alluminium alloy
(prefered version for its
lightness and strength)
GALV
galvanised steel
INOX
stainless steel AISI 304
(31 - 42 models only available in ALU version)
Fan versions
STANDARD
galvanised steel STANDARD
AETERNUM galvanised steel
structure and AISI 304 stainless steel
(only 31-53 models)
Motors
Accessories
Humidification and cooling function
RWA
+
SVG
microcomputer
TPR TPU
magnetothermic motorstarter
modules
switch
A wide variety of applications
All data in this catalogue are indicative and are subject to change without prior notice.
www.pericoli.com
PERICOLI ASIA PACIFIC Sdn. Bhd.
14, Jalan Sejahtera 25/124, Axis Industrial Park, Sec. 25, 40400 Shah Alam, Selangor – Malaysia
tel. +603 – 5122 3880 - fax +603 – 5122 5899 info@pericoli-asiapacific.com
www.pericoli.com
Release - July 2019
All the products included in this catalogue are designed and created by Termotecnica Pericoli S.r.l. and produced in our Pericoli Asia Pacific Sdn. Bhd. facility.