50 Hz
Electric Pumps Catalogue
Heating, ventilation
and air-conditioning
Circulator pumps for circulation of hot water in central
heating systems and circulation in domestic hot water
service systems. Pumps for circulation of cold water
and other liquids in cooling and air-conditioning systems.
Groundwater supply
Submersible pumps for groundwater supply, irrigation
and groundwater lowering.
INDEX
50 Hz
Surface pumps
VARIO VERTICAL MULTISTAGE CENTRIFUGAL PUMPS WITH FREQUENCY CONVERTER 6
DOMINATOR 4 4’’ SUBMERSIBLE MULTISTAGE CENTRIFUGAL PUMPS FOR CLEAN WATER 116
SCM 4 PLUS 4’’ MULTISTAGE CENTRIFUGAL SUBMERSIBLE PUMPS COMPLETE WITH MOTOR 120
SCM 4 HF 400 4’’ MULTISTAGE CENTRIFUGAL SUBMERSIBLE PUMPS COMPLETE WITH MOTOR 129
SIMER SIMO PUMP SUBMERSIBLE PUMP FOR DRAINING CLEAR WATER 146
VACUSYSTEM MINI COLLECTION AND PUMPING STATIONS FOR WASTE WATER 186
BLAZE - BLAZEMASTER SINGLE AND TWIN IMPELLER ENGINE DRIVEN PUMPS 200
PGA - DELTA OIL SELF-PRIMING LIQUID RING PUMPS FOR DIESEL TRANSFER 202
Booster sets
HOW TO CHOOSE A BOOSTER SET 207
AUTOJET BOOSTER SET WITH ELECTRONIC CONTROL AND PROTECTION DEVICE 210
AUTOMAX BOOSTER SET WITH ELECTRONIC CONTROL AND PROTECTION DEVICE 212
FLUSSCONTROL/
235
FLUSSCONTROL BASIC ELECTRONIC CONTROL AND PROTECTION DEVICES
INDEX
ACCESSORIES PRESSURE SWITCHES, PRESSURE GAUGES, FLEXIBLE PIPES, VALVES, FLOAT SWITCHES, FILTERS 250
CONTENTS IN ALPHABETIC ORDER
50 Hz
ACCESSORIES PRESSURE SWITCHES, PRESSURE GAUGES, FLEXIBLE PIPES, VALVES, FLOAT SWITCHES, FILTERS 250
ACCESSORIES VLR / VLRX CONNECTIONS AND FLANGES 36
AP DEEP SUCTION SELF-PRIMING PUMPS 50
A AQUA MATIC / AQUA TROL ELECTRONIC CONTROL AND PROTECTION DEVICE 235
AUTOJET BOOSTER SET WITH ELECTRONIC CONTROL AND PROTECTION DEVICE 210
AUTOMAX BOOSTER SET WITH ELECTRONIC CONTROL AND PROTECTION DEVICE 212
B BLAZE - BLAZEMASTER SINGLE AND TWIN IMPELLER ENGINE DRIVEN PUMPS 200
ELECTRIC PANELS CONTROL PANELS FOR SINGLE AND THREE PHASE PUMPS 241
EP PERIPHERAL PUMPS 110
50 Hz
NRM CLOSE-COUPLED CENTRIFUGAL PUMPS. 2 AND 4 POLES 69
N NRB CENTRIFUGAL PUMPS WITH BASE-PLATE AND COUPLING. 2 AND 4 POLES. 89
NRI BARESHAFT END-SUCTION CENTRIFUGAL PUMPS 105
PGA - DELTAOIL SELF-PRIMING LIQUID RING PUMPS FOR DIESEL TRANSFER 202
PRATIKA MULTISTAGE CENTRIFUGAL SUBMERSIBLE PUMPS FOR CLEAR WATER 114
P PRESSOMAT BOOSTER SET WITH TWO PUMPS 222
PRIOX SUBMERSIBLE EFFLUENT VORTEX PUMPS FOR DIRTY WATER 159
VACUSYSTEM MINI COLLECTION AND PUMPING STATIONS FOR WASTE WATER 186
VARIO VERTICAL MULTISTAGE CENTRIFUGAL PUMPS WITH FREQUENCY CONVERTER 6
VERSAILLES SUBMERSIBLE PUMPS FOR FOUNTAINS AND WATER FEATURES 204
V VLR VERTICAL MULTISTAGE CENTRIFUGAL PUMPS 12
VLRX VERTICAL MULTISTAGE CENTRIFUGAL PUMPS IN AISI 316 STAINLESS STEEL 26
VSD VARIABLE SPEED DRIVE 232
Motor
- Asynchronous electric motor with
enclosed stator and external ventilation.
- Main dimensions are in accordance
with DIN and IEC standards.
- Class F insulation.
- Level of protection IP 55.
- Maximum environmental temperature
40°C
- Speed of rotation 2900 rpm.
Minimum suction Please refer to the NPSH values with a safety margin of 0.5 mt
head
DESIGN FEATURES
Component Material
1 Base EN GJL 200 (ex G20) Grey cast iron
2 Adapter EN GJL 200 (ex G20) Grey cast iron
3 Motor joint EN GJS 400 (ex GS400) Spheroidal cast iron
4 Outer liner X5 CrNi 1810 (AISI 304) Stainless steel
5 Impeller X5 CrNi 1810 (AISI 304) Stainless steel
6 Intermediate chamber X5 CrNi 1810 (AISI 304) Stainless steel
7 Mechanical seal Tungsten carbide
8 Counterface Tungsten carbide
9 Shaft X2 CrNi/MO 17-12-2 ( AISI 316 ) Stainless steel
10 O'ring EPDM rubber
6
VARIO
60 V1-VLR2B 0,6
/60
40 0,4
20 0,2
0 0
L / 1' 10 20 30 40 50 60 70
Q
m3/ h 0,6 1,20 1,80 2,4 3,0 3,6 4,2
ØD
PUMP PERFORMANCE
Motor
L/1' 10 20 30 40 50 58
CODE MODEL Power Supply Output Amp. Q 3
HP kW Voltage Voltage m /h 0.6 1.2 1.8 2.4 3.0 3.5
B1
60
100
156
22 160 22
A1 B1 L1 C D DNA-DNM (kg)
20
Ø 1"gas
V1-VLR2B/60 296 237 533 350 160 1” 30 65
V1-VLR2B/90 350 237 587 350 160 1” 38 104
Ø 13,5
180
V1-VLR2B/110 386 237 623 350 160 1” 40 210
441 265 706 375 185 1” 41 C
V1-VLR2B/130
7
VARIO
TABLE OF HYDRAULIC PERFORMANCE
H P
(m) (MPa)
140 1,4
VARIO 1
VLR4
120 V1-VLR4 1,2
/120
100 V1-VLR4 1
/100
80 V1-VLR4 0,8
/80
V1-VLR4/80-7
60 V1-VLR4/60 0,6
40 0,4
20 0,2
0 0
L / 1' 20 40 60 80 100 120 140
Q
m3/ h 1,20 2,40 3,6 4,8 6,0 7,2 8,4
ØD
PUMP PERFORMANCE
Motor
L/1' 20 40 60 80 100 133
CODE MODEL Power Supply Output Amp. Q 3
HP kW Voltage Voltage m /h 1.2 2.4 3.6 4.8 6.0 8.0
B1
L1
60
100
156
22 160 22
65
V1-VLR4/80 423 265 688 375 185 1”1/4 37 104
Ø 13,5
V1-VLR4/100 477 265 742 375 185 1”1/4 40 180
210
V1-VLR4/120 531 265 796 375 185 1”1/4 41 C
8
VARIO
TABLE OF HYDRAULIC PERFORMANCE
H P
(m) (MPa)
70 0,7
V1-VLR
VARIO 1
8/60 VLR8
60 0,6
V1-VLR8
/50
50 0,5
40 0,4
30 0,3
20 0,2
10 0,1
0 0
L / 1' 50 100 150 200 250
Q
m3/ h 3,0 6,0 9,0 12,0 15,0
ØD
PUMP PERFORMANCE
Motor
L/1' 50 100 125 150 175 200
CODE MODEL Power Supply Output Amp. Q 3
HP kW Voltage Voltage m /h 3 6 7,5 9 10,5 12
B1
Discharge
in meters
63 59 55 49 42 35
A1
80
130
190
27 200 27
Weight
20
Model Dimensions mm
Ø 1" 1/2 gas
9
VLR / VLRX / VLRI
VERTICAL MULTISTAGE CENTRIFUGAL PUMPS
ASSEMBLED WITH ELECTRIC MOTOR
Identification Name
VLR X 16 40 F T
T = Three phase
M = Single phase
“F” "in line" round flange
“A” "in line" oval flange
“V” with couplings for victaulic joints
Number of stages X 10
Nominal flow in mc3/h
Materials used:
X = AISI 316
I = AISI 304
- AISI 304 hydraulic end and cast iron base
Model
2B 4 8 16 30B 60B
VLRX
VLRX
VLRX
VLRX
VLRX
VLRX
VLRI
VLRI
VLRI
VLRI
VLRI
VLRI
MODEL
VLR
VLR
VLR
VLR
VLR
VLR
10
VLR / VLRX / VLRI
Performance range
VLR
H
[m]
300
200
VLR 16
VLR 8
100 VLR 2B VLR 4
90
80
VLR 30B
70
60
50
VLR 60B
40
30
20
1 2 3 4 5 6 7 8 910 20 30 40 50 60 708090100 Q [m3/h]
VLRX / VLRI
H
[m]
300
200
VLR / VLRX / VLRI
80
70 VLRX 2B
60 VLRI 2B
50
40
30
20
1 2 3 4 5 6 7 8 910 20 30 40 50 60 708090100 Q [m3/h]
11
VLR
VERTICAL MULTISTAGE CENTRIFUGAL PUMPS
The VLR are vertical multistage, in-line, centrifugal pumps, directly connected to an
electric motor. They are not self-priming.
Applications Motor
- Water supply - Asynchronous electric motor with
- Pressure Booster Systems enclosed stator and external
- Irrigation ventilation
- High pressure washes - Main dimensions are in accordance
- Firefighting systems with DIN and IEC standards
- Boiler supply - Design: V18-up to 4,0Kw
- Liquid transfer V1- to start from 5,5Kw
- Class F insulation
- Level of protection IP 55
- Maximum environmental
temperature 40 °C
- Speed of rotation 2900 rpm
Versions Available
- All the "A" versions are complete with oval gas cast iron counterflanges
- The "F" version is complete with DIN round flanges
Round counterflanges on request for VLR 2B-4-8-16
Supplied complete with round counterflanges for VLR 30B-60B
2
3
8
4 DESIGN FEATURES
5
6 Component Material
9
1 Base EN GJL 200 ( ex G20 ) Grey cast iron
2 Adapter EN GJL 200 ( ex G20 ) Grey cast iron
1
3 Motor joint EN GJS 400 ( ex GS400 ) Spheroidal cast iron
4 Outer liner X5 CrNi 1810 ( AISI 304 ) Stainless steel
5 Impeller X5 CrNi 1810 ( AISI 304 ) Stainless steel
6 Intermediate chamber X5 CrNi 1810 ( AISI 304 ) Stainless steel
7 Mechanical seal Tungsten carbide
8 Counterface Tungsten carbide
9 Shaft X2 CrNi/MO 17-12-2 ( AISI 316 ) Stainless steel
10 O’ring EPDM rubber
12
VLR
USAGE LIMITATIONS
VLR 2B - VLR 4 VLR 8
Oval flanges DIN Flanges Oval flanges DIN Flanges
Liquid temperature -15° a +120° -15° a +120°
VLR2B/30-2 VLR8/20-VLR8/30
6bar 6 bar
VLR4/20
Maximum inlet pressure VLR2B/30-VLR2B/110 16 bar
VLR4/30-VLR4/100 10bar
VLR8/40-VLR8/200
VLR2B/130-VLR2B/260 10 bar
15bar
VLR4/120-VLR4/260
Minimum suction head Please refer to the NPSH values with a safety margin of 0,5 m
USAGE LIMITATIONS
VLR 16 VLR 30B VLR 60B
DIN Flanges DIN Flanges DIN Flanges
Liquid temperature -15° a +120° -20° a +120° -20° a +120°
VLR16/30-2 - VLR16/160 25 bar
(max. temp. 85°) Max operating
Maximum operating pressure pressure
VLR16/30-2 - VLR16/160 23 bar (sustion included)
(max. temp. 120°) Max operating
16 bar
pressure
(VLR30B/20-
(sustion included)
VLRB/60)
VLR16/30-2 - VLR16/30 16 bar
6 bar 25 bar
Maximum inlet pressure (VLR30B/70-
VLR30B/120)
VLR16/40 - VLR16/160
10 bar
Minimum suction head Please refer to the NPSH values with a safety margin of 0,5 m
VLR
13
VLR 2B
TABLE OF HYDRAULIC PERFORMANCE
VLR 2B
50 Hz
14
VLR 2B
PUMP PERFORMANCE
Motor L/1' 10 20 30 40 50
Power Amp. µF.
CODE MODEL VOLTAGE Q
m /h
3 ➊Version with oval flanges
HP kW 0,6 1,2 1,8 2,4 3
VLR 2B 30/2 - VLR 2B 150❷
E2302102 VLR 2B - 30/2 A M 1 ~ 230 V 2,7 14 H
0,5 0,37 19 18 17 14 11
E2301002 VLR 2B - 30/2 A T 3 ~ 230 ÷ 400 V 1-0,6 ØD
B1
E2302104 VLR 2B - 40 A M 1 ~ 230 V 4 16
0,75 0,55 37 35 32 29 23
E2301004 VLR 2B - 40 A T 3 ~ 230 ÷ 400 V 1,8-1
3/4"
E2302105 VLR 2B - 50 A M 1 ~ 230 V 4 16
L1
0,75 0,55 47 43 40 35 28
E2301005 VLR 2B - 50 A T 3 ~ 230 ÷ 400 V 2,3-1,3
A1
E2302106 VLR 2B - 60 A M 1 ~ 230 V 5,2 25
1 0,75 56 51 48 42 33
E2301006 VLR 2B - 60 A T 3 ~ 230 ÷ 400 V 2,7-1,5
50
E2302107 VLR 2B - 70 A M 1 ~ 230 V 5,2 25
1 0,75 65 60 55 49 39
E2301007 VLR 2B - 70 A T 3 ~ 230 ÷ 400 V 3-1,7 60
100
Discharge head
156
E2302109 VLR 2B - 90 A M 1 ~ 230 V 8 35 22 22
1,5 1,1 84 78 70 62 50 160
in meters
E2301009 VLR 2B - 90 A T 3 ~ 230 ÷ 400 V 3,6-2,1
65
E2302111 VLR 2B - 110 A M 1 ~ 230 V 8 35
1,5 1,1 100 93 84 74 60 3/8" M 10x40
E2301011 VLR 2B - 110 A T 3 ~ 230 ÷ 400 V 4,3-2,5
E2302113 VLR 2B - 130 A M 1 ~ 230 V 12 45
20
2 1,5 120 112102 89 71
E2301013 VLR 2B - 130 A T 3 ~ 230 ÷ 400 V 5-2,9 Ø 1"gas
104 Ø 13,5
180
E2302115 VLR 2B - 150 A M 1 ~ 230 V 12 45 210
2 1,5 138 129116 99 81
E2301015 VLR 2B - 150 A T 3 ~ 230 ÷ 400 V 5,7-3,3
E2331018 VLR 2B - 180 F T 3 2,2 3 ~ 230 ÷ 400 V 7,2-4,1 166 155 141122 99
E2331022 VLR 2B - 220 F T 3 2,2 3 ~ 230 ÷ 400 V 8,7-5 199 185168 145 118
E2331026 VLR 2B - 260 F T 4 3 3 ~ 230 ÷ 400 V 11,4-6,6 232 220200 173 141
3/4"
TABLE OF SIZES AND WEIGHTS
L2
A2
VLR 2B - 110
32
131
78
15
VLR 4
TABLE OF HYDRAULIC PERFORMANCE
VLR 4
50 Hz
16
VLR 4
PUMP PERFORMANCE
Motor 40 60 80 100 120
Power L/1'
CODE MODEL VOLTAGE Amp. µF. Q ❶ Version with oval flanges❷
HP kW m /h
3
2,4 3,6 4,8 6 7,2
VLR 4-20 - VLR 4-160
E3502102 VLR 4 - 20 A M 1 ~ 230 V 2,7 14
0,5 0,37 19 17 15 13 9
E3501002 VLR 4 - 20 A T 3 ~ 230 ÷ 400 V 1,73-1 H
ØD
E3502103 VLR 4 - 30 A M 1 ~ 230 V 4 16
0,75 0,55 28 25 22 19 13
E3501003 VLR 4 - 30 A T 3 ~ 230 ÷ 400 V 2,5-1,45
E3502104 VLR 4 - 40 A M 1 ~ 230 V 5,2 25
B1
1 0,75 36 33 29 25 18
E3501004 VLR 4 - 40 A T 3 ~ 230 ÷ 400 V 3,3-1,9
E3502105 VLR 4 - 50 A M 1 ~ 230 V 8 35
1,5 1,1 44 42 37 31 23
E3501005 VLR 4 - 50 A T 3 ~ 230 ÷ 400 V 4,3-2,5 3/4"
L1
E3502106 VLR 4 - 60 A M 1 ~ 230 V 8 35
1,5 1,1 53 50 44 38 27
A1
E3501006 VLR 4 - 60 A T 3 ~ 230 ÷ 400 V 4,3-2,5
E3502107 VLR 4 - 80/7 A M 1 ~ 230 V 12 45
2 1,5 61 58 51 44 32
E3501007 VLR 4 - 80/7 A T 3 ~ 230 ÷ 400 V 5,9-3,4
50
E3502108 VLR 4 - 80 A M 1 ~ 230 V 12 45 60
2 1,5 71 67 59 50 37
Discharge head
E3501008 VLR 4 - 80 A T 3 ~ 230 ÷ 400 V 5,9-3,4 100
156
in meters
22 160 22
E3501010 VLR 4 - 100 A T 3 2,2 3 ~ 230 ÷ 400 V 8,3-4,8 90 82 72 61 46
65
E3501012 VLR 4 - 120 A T 3 2,2 3 ~ 230 ÷ 400 V 8,3-4,8 107 99 87 73 54 3/8" M 10x40
20
1
Ø 1 /4"gas
104 Ø 13,5
180
E3501016 VLR 4 - 160 A T 4 3 3 ~ 230 ÷ 400 V 10,9-6,3 142 132 116 97 72 210
E3531019 VLR 4 - 190 F T 5,5 4 3 ~ 230 ÷ 400 V 13,8-8 170 157 138 114 86
E3531119 VLR 4 - 190 F T 3 ~ 400 ÷ 690 V
E3531022 VLR 4 - 220 F T 3 ~ 230 ÷ 400 V
5,5 4 13,8-8 196 181 160 131 101
E3531122 VLR 4 - 220 F T 3 ~ 400 ÷ 690 V
E3531024 VLR 4 - 240 F T 7,5 5,5 3 ~ 230 ÷ 400 V 12,4-21,5
213 198 175 143 110
E3531124 VLR 4 - 240 F T 3 ~ 400 ÷ 690 V
E3531026 VLR 4 - 260 F T
7,5 5,5 3 ~ 230 ÷ 400 V 12,4-21,5 230 213 189 156 120
E3531126 VLR 4 - 260 F T 3 ~ 400 ÷ 690 V
- VLR 4 version "A": complete with 1" gas oval counterflanges
- VLR 4 version "F": round counterflanges on request
❷ Version with flanges
PN10 DIN 2534/ISO 7005-2
❷
H
ØD
A1 1 B1 L1 1 A2 2 L2 2 D H
A2
3/8" 3/8"
VLR 4 - 20 238 213 451 - - 142 109 20 -
VLR 4 - 30 265 213 478 - - 142 109 21 -
VLR 4 - 40
75
180 4 holes
210
VLR 4 - 240 - 385 - 911 1298 260 185 - 87
VLR 4 - 260 - 385 - 965 1350 260 185 - 89
17
VLR 8
TABLE OF HYDRAULIC PERFORMANCE
VLR 8
50 Hz
18
VLR 8
PUMP PERFORMANCE
Motor 50 100 150 175 200
Power L/1'
CODE MODEL VOLTAGE Amp. µF. Q
3 ➊ Version with oval flanges
HP kW m /h 3 6 9 10,5 12
❷ VLR 8-20 - VLR 8-120
E4502102 VLR 8 - 20 A M 1 ~ 230 V 5,2 25
1 0,75 21 20 18 15 13
E4501002 VLR 8 - 20 A T 3 ~ 230 ÷ 400 V 3,3-1,9 H
ØD
E4502103 VLR 8 - 30 A M 1 ~ 230 V 8 35
1,5 1,1 32 30 27 23 19
E4501003 VLR 8 - 30 A T 3 ~ 230 ÷ 400 V 4,3-2,5
E4502104 VLR 8 - 40 A M 1 ~ 230 V 12 45
2 1,5 42 40 35 30 26
B1
E4501004 VLR 8 - 40 A T 3 ~ 230 ÷ 400 V 5,9-3,4
L1
E4501006 VLR 8 - 60 A T 3 2,2 3 ~ 230 ÷ 400 V 8,8-5,1 64 60 52 45 39
A1
E4501008 VLR 8 - 80 A T 4 3 3 ~ 230 ÷ 400 V 11,8-6,8 85 80 70 60 52
Discharge head
80
E4501010 VLR 8 - 100 A T 3 ~ 230 ÷ 400 V
in meters
5,5 4 16,8-9,7 106 100 88 76 65
E4501110 VLR 8 - 100 A T 3 ~ 400 ÷ 690 V 130
190
E4501012 VLR 8 - 120 A T 3 ~ 230 ÷ 400 V 27 200 27
5,5 4 16,8-9,7 127 119 104 90 77
E4501112 VLR 8 - 120 A T 3 ~ 400 ÷ 690 V
100
E4531014 VLR 8 - 140 F T 3 ~ 230 ÷ 400 V 21,5-12,4
7,5 5,5 149 130 122 105 92 M 12x45
E4531114 VLR 8 - 140 F T 3 ~ 400 ÷ 690 V
E4531016 VLR 8 - 160 F T 3 ~ 230 ÷ 400 V 21,5-12,4
7,5 5,5 171 160 138 120 104
20
E4531116 VLR 8 - 160 F T 3 ~ 400 ÷ 690 V Ø 1"1/2 gas
155
E4531018 VLR 8 - 180 F T 3 ~ 230 ÷ 400 V 28-16,4 215
Ø 13
10 7,5 193 181 160 135 120
E4531118 VLR 8 - 180 F T 3 ~ 400 ÷ 690 V 246
Ø D3
L2
A2
B1 D H D3
VLR 8 - 20 245 237 482 - - 160 131 - 30 -
VLR 8 - 30 375 237 612 - - 160 131 - 32 - 130
190
VLR 8 - 40 420 265 685 - - 185 130 - 40 - 280
VLR 8 - 50 450 265 715 - - 185 130 - 42 -
3/8"
VLR 8 - 60 480 265 745 - - 185 130 - 43 - n˙4 holes Ø 18
VLR 8 - 80 545 315 860 - - 200 140 - 51 -
VLR 8 - 100 605 335 940 - - 200 140 - 52 -
110
150
40
88
215 4 holes
246
VLR 8 - 180 - 385 - 865 1250 260 185 300 - 90
VLR 8 - 200 - 385 - 925 1310 260 185 300 - 91
19
VLR 16
TABLE OF HYDRAULIC PERFORMANCE
VLR 16
50 Hz
20
VLR 16
PUMP PERFORMANCE
Motor
Power L/1' 100 200 250 300 350
CODE MODEL VOLTAGE Amp. Q
HP kW m /h
3
6 12 15 18 21
Discharge head
7,5 5,5 21,5-12,4 87 81 78 68 58
E5501106 VLR 16 - 60 F T 3 ~ 400 ÷ 690 V
in meters
E5501007 VLR 16 - 70 F T 3 ~ 230 ÷ 400 V 28-16,4
10 7,5 101 95 90 80 67
E5501107 VLR 16 - 70 F T 3 ~ 400 ÷ 690 V
E5501008 VLR 16 - 80 F T 3 ~ 230 ÷ 400 V
10 7,5 28-16,4 116 108102 92 76
E5501108 VLR 16 - 80 F T 3 ~ 400 ÷ 690 V
E5501010 VLR 16 - 100 F T 3 ~ 230 ÷ 400 V
15 11 40-23,5 145 136130 118 98
E5501110 VLR 16 - 100 F T 3 ~ 400 ÷ 690 V
E5501012 VLR 16 - 120 F T 3 ~ 230 ÷ 400 V
15 11 40-23,5 174 163156 140118
E5501112 VLR 16 - 120 F T 3 ~ 400 ÷ 690 V
E5501014 VLR 16 - 140 F T 3 ~ 230 ÷ 400 V
20 15 50-29 204 190184 163140
E5501114 VLR 16 - 140 F T 3 ~ 400 ÷ 690 V
E5501016 VLR 16 - 160 F T 3 ~ 230 ÷ 400 V
20 15 50-29 232 220208 188159
E5501116 VLR 16 - 160 F T 3 ~ 400 ÷ 690 V
Ø D3
L
3/8" 3/8"
90
DN 50
VLR 16 - 70 665 385 1050 260 185 300 90
155 n 4 holes
VLR 16 - 80 710 385 1095 260 185 300 92 Ø 13
215
VLR 16 - 100 830 495 1325 260 185 350 136 246
21
VLR 30B
TABLE OF HYDRAULIC PERFORMANCE
VLR 30B
50 Hz
Kw
22
VLR 30B
PUMP PERFORMANCE
Motor 233 300 350 400 500 600
Power L/1'
CODE MODEL VOLTAGE Amp. Q 3
HP kW m /h 14 18 21 24 30 36
Discharge head
in meters
E6500050 VLR 30B - 60 F 15,00 11,00 3 ~ 400/690 V 21,0 117 110 105 97 79
E6500060 VLR 30B - 70 F 20,00 15,00 3 ~ 400/690 V 29,0 136 129 123 113 92 67
E6500070 VLR 30B - 80 F 20,00 15,00 3 ~ 400/690 V 29,0 155 147 140 130 106 77
E6500080 VLR 30B - 90 F 20,00 15,00 3 ~ 400/690 V 29,0 175 166 158 146 119 86
E6500090 VLR 30B - 100 F 25,00 18,50 3 ~ 400/690 V 35,0 194 184 175 162 132 96
E6500100 VLR 30B - 110 F 25,00 18,50 3 ~ 400/690 V 35,0 214 202 193 178 145 106
E6500110 VLR 30B - 120 F 30,00 22,00 3 ~ 400/690 V 42,0 233 221 210 194 158 115
ØD1
L2
ØD2
H
L1+L2
G 1/2 LOAD
L1
Rp 3/8 Rp 3/8
DNA DNM
TABLE OF SIZES AND WEIGHTS
A
B
end (kg) G 1/2 LOAD
DNA/ Pump- Electric
L1 L2 A B M D1 D2 H end pump
DNM
VLR 30B - 20 65 588 312 105 320 136 193 160 170 48 78
VLR 30B - 30 65 680 350 105 320 150 220 300 190 56 102
VLR 30B - 40 65 752 350 105 320 150 220 300 190 59 109
VLR 30B - 50 65 856 495 105 320 228 316 350 222 70 155
220
260
VLR 30B - 60 65 1120 495 105 320 228 316 350 222 83 168
VLR 30B - 70 65 1192 495 105 320 228 316 350 222 86 178
Ø 15
VLR 30B - 80 65 1264 495 105 320 228 316 350 222 89 181 Nº 4 HOLES 220
260
VLR 30B - 90 65 1336 495 105 320 228 316 350 222 93 185
VLR 30B - 100 65 1408 495 105 320 228 316 350 222 96 195
VLR
VLR 30B - 110 65 1480 495 105 320 228 316 350 222 99 198
VLR 30B - 120 65 1552 495 105 320 245 316 350 222 102 216
23
VLR 60B
TABLE OF HYDRAULIC PERFORMANCE
VLR 60B
50 Hz
Kw
24
VLR 60B
PUMP PERFORMANCE
Motor 400 500 600 800 1000 1200
Power L/1'
CODE MODEL VOLTAGE Amp. Q m3/h
HP kW 24 30 36 48 60 72
Discharge head
E7500030 VLR 60B - 40 F 15,00 11,00 3 ~ 400/690 V 21,0 67 63 60 51 38 23
in meters
E7500040 VLR 60B - 50 F 20,00 15,00 3 ~ 400/690 V 29,0 84 80 75 63 48 28
E7500060 VLR 60B - 70 F 25,00 18,50 3 ~ 400/690 V 35,0 118 112 105 88 67
E7500070 VLR 60B - 80 F 30,00 22,00 3 ~ 400/690 V 42,0 135 128 120 102 77 46
ØD1
L2
ØD2
H
L1+L2
G 1/2 LOAD
L1
Rp 3/8 Rp 3/8
DNA DNM
A
35
B
G 1/2 LOAD
VLR 60B - 20 100 658 350 140 365 150 220 300 190 57 103
VLR 60B - 30 100 730 350 140 365 150 220 300 190 60 110
Ø 15
VLR 60B - 40 100 834 495 140 365 228 316 350 222 71 156 Nº 4 HOLES 220
260
VLR 60B - 50 100 906 495 140 365 228 316 350 222 74 166
VLR 60B - 60 100 1170 495 140 365 228 316 350 222 87 179
VLR
VLR 60B - 70 100 1242 495 140 365 228 316 350 222 90 189
VLR 60B - 80 100 1314 495 140 365 245 316 350 222 94 208
25
VLRX
VERTICAL MULTISTAGE CENTRIFUGAL
PUMPS IN AISI 316 STAINLESS STEEL
The VLRX are vertical multistage, in-line, centrifugal pumps, directly connected to an
electric motor. They are not self-priming.
Entirely in AISI 316 stainless steel for sea water and special applications.
The range is available also in AISI 304 stainless steel (VLRI)
Applications Motor
- Water supply - Asynchronous electric motor with
- Pressure Booster Systems enclosed stator and external
- Irrigation ventilation
- High pressure washes - Main dimensions are in accordance
- Firefighting systems with DIN and IEC standards
- Boiler supply - Design: V18-up to 4,0Kw
- Liquid transfer V1- to start from 5,5Kw
- Class F insulation
- Level of protection IP 55
- Maximum environmental
temperature 40 °C
- Speed of rotation 2900 rpm
Identification Name
VLR X 16 40 F T
T = Three phase
M = Single phase
“F” "in line" round flange
“A” "in line" oval flange
“V” with couplings for victaulic joints
Number of stages X 10
Nominal flow in mc3/h
Materials used:
X = AISI 316
I = AISI 304
5
10 Model
4
3
9
6 DESIGN FEATURES
7
8 Component Material
11
1 Base plate Cast iron/steel ( VLR 2-4 ) Cast iron ( VLR 8-16 )
2 Pump body X CrNiMo 17-12-03 ( AISI 316 ) Stainless steel
3 Seal guard X CrNiMo 17-12-03 ( AISI 316 ) Stainless steel
4 Adapter EN GJL 200 ( ex G20 ) Grey cast iron
5 Motor joint EN GJS 400 ( ex GS400 ) Spheroidal cast iron
6 Outer liner X CrNiMo 17-12-03 ( AISI 316 ) Stainless steel
7 Impeller X CrNiMo 17-12-03 ( AISI 316 ) Stainless steel
8 Intermediate chamber X CrNiMo 17-12-03 ( AISI 316 ) Stainless steel
9 Mechanical seal Tungsten carbide
10 Counterface Tungsten carbide
2
1 11 Shaft X CrNiMo 17-12-03 ( AISI 316 ) Stainless steel
26
VLRX
USAGE LIMITATIONS
VLRX 2B VLRX 4
Minimum suction head Please refer to the NPSH values with a safety margin of 0,5m
USAGE LIMITATIONS
VLRX 8 VLRX 16
Minimum suction head Please refer to the NPSH values with a safety margin of 0,5m
VERSIONS AVAILABLE
2B 4 8 16
VLRX
VLRX
VLRX
VLRX
VLRI
VLRI
VLRI
VLRI
VERSIONS
X = standard version
= available on request
VLRX
27
VLRX 2B
TABLE OF HYDRAULIC PERFORMANCE
VLRX 2B
50 Hz
28
VLRX 2B
PUMP PERFORMANCE
Motor
Power L/1' 10 20 30 40 50
CODE MODEL VOLTAGE Amp. µF. Q 3
HP kW m /h 0,6 1,2 1,8 2,4 3,0
E2730010 VLRX 2B- 30/2 F M 1 ~ 230 V 2,7 14
19 18 17 14 11
E2730020 VLRX 2B- 30/2 F T 0,50 0,37 3 ~ 230÷400 V 1,0 - 0,6
E2730030 VLRX 2B- 30 F M 1 ~ 230 V 2,7 14
E2730040 VLRX 2B- 30 F T 0,50 0,37 3 ~ 230÷400 V 29 27 25 21 17
1,4 - 0,8
E2730050 VLRX 2B- 40 F M 1 ~ 230 V 4,0 16
E2730060 VLRX 2B- 40 F T 0,75 0,55 3 ~ 230÷400 V 37 35 32 29 23
1,8 - 1,0
E2730070 VLRX 2B- 50 F M 1 ~ 230 V 4,0 16
E2730080 VLRX 2B- 50 F T 0,75 0,55 3 ~ 230÷400 V 2,3 - 1,3 47 43 40 35 28
E2730090 VLRX 2B- 60 F M 1 ~ 230 V 5,2 25
E2730100 VLRX 2B- 60 F T 1,00 0,75 3 ~ 230÷400 V 2,7 - 1,5 56 51 48 42 33
Discharge head
65 50 55 49 39
E2730120 VLRX 2B- 70 F T 1,00 0,75 3 ~ 230÷400 V 3,0 - 1,7
in meters
E2730130 VLRX 2B- 90 F M 1 ~ 230 V 8,0 35 84 78 70 62 50
E2730140 VLRX 2B- 90 F T 1,50 1,10 3 ~ 230÷400 V 3,6 - 2,1
E2730150 VLRX 2B-110 F M 1 ~ 230 V 8,0 35
E2730160 VLRX 2B-110 F T 1,50 1,10 3 ~ 230÷400 V 4,3 - 2,5 100 93 84 74 60
E2730210 VLRX 2B-180 F T 3,00 2,20 3 ~ 230÷400 V 7,2 - 4,1 166 155 141 122 99
E2730220 VLRX 2B-220 F T 3,00 2,20 3 ~ 230÷400 V 8,7 - 5,0 199 185 168 145 118
E2730230 VLRX 2B-260 F T 4,00 3,00 3 ~ 230÷400 V 11,4 - 6,6 232 220 200 173 141
VERSIONS AVAILABLE :
H
- "F": in line ports with round flanges.
ØD
Counterflanges on request.
- "A" (on request): in line ports with 1" gas oval flanges.
1"1/4 gas oval counterflanges.
-"V" (on request): with 1" 1/4 couplings for VICTAULIC joint
B1
3/4"
L2
A2
3/8" 3/8"
75
A B L D H
VLRX 2B - 30/2 F 250 215 465 158 168 26
VLRX 2B - 30 F 250 215 465 158 168 27
3/8"
VLRX 2B - 40 F 268 215 483 158 168 29
n˙4 holes Ø 18
VLRX 2B - 50 F 286 215 501 158 168 31
VLRX 2B - 60 F 308 245 553 170 203 32
100
140
32
78
210
VLRX 2B - 150 F 489 255 744 180 205 49
VLRX 2B - 180 F 568 280 848 180 205 49
VLRX 2B - 220 F 640 280 920 180 205 61
VLRX 2B - 260 F 716 300 1016 196 235 63
29
VLRX 4
TABLE OF HYDRAULIC PERFORMANCE
VLRX 4
50 Hz
30
VLRX 4
PUMP PERFORMANCE
Motor L/1' 40 60 80 100 120
Power
CODE MODEL VOLTAGE Amp. µF Q m3/h
HP kW 2,4 3,6 4,8 6,0 7,2
E3730010 VLRX 4- 20 F M 1 ~ 230 V 2,7 14
0,50 0,37 19 17 15 13 9
E3730020 VLRX 4- 20 F T 3 ~ 230÷400 V 1,7 - 1,0
E3730030 VLRX 4- 30 F M 1 ~ 230 V 4,0 16
E3730040 VLRX 4- 30 F T 0,75 0,55 3 ~ 230÷400 V 28 25 22 19 13
2,5 - 1,4
E3730050 VLRX 4- 40 F M 1 ~ 230 V 5,2 25
1,00 0,75 3 ~ 230÷400 V 36 33 29 25 18
E3730060 VLRX 4- 40 F T 3,3 - 1,9
E3730070 VLRX 4- 50 F M 1 ~ 230 V 8,0 35
E3730080 VLRX 4- 50 F T 1,50 1,10 3 ~ 230÷400 V 44 42 37 31 23
4,3 - 2,5
E3730090 VLRX 4- 60 F M 1 ~ 230 V 8,0 35
1,50 1,10 3 ~ 230÷400 V 53 50 44 38 27
E3730100 VLRX 4- 60 F T 4,3 - 2,5
E3730110 VLRX 4- 80/7 F M 1 ~ 230 V 12 45
2,00 1,50 61 58 51 44 32
E3730120 VLRX 4- 80/7 F T 3 ~ 230÷400 V 5,9 - 3,4
E3730130 VLRX 4- 80 F M 1 ~ 230 V 12 45 71 67 59 50 37
E3730140 VLRX 4- 80 F T 2,00 1,50 3 ~ 230÷400 V
Discharge head
5,9 - 3,4
in meters
E3730150 VLRX 4-100 F T 3,00 2,20 3 ~ 230÷400 V 8,3 - 4,8 90 82 72 61 46
E3730170 VLRX 4-140 F T 4,00 3,00 3 ~ 230÷400 V 10,9 - 6,3 124 116 102 85 63
E3730180 VLRX 4-160 F T 4,00 3,00 3 ~ 230÷400 V 10,9 - 6,3 142 132 116 97 72
VERSIONS AVAILABLE:
- “F”: in line ports with round flanges.
Counterflanges on request.
- “A” (on request): in line ports with 1” gas oval flanges.
B1
3/8" 3/8"
Net weight
Model Dimensions in mm (kg) 60
100
156
A B L D H
250
VLRX 4 - 20 F 250 215 465 158 168 26
VLRX 4 - 30 F 277 215 492 158 168 27
VLRX 4 - 40 F 308 245 553 170 203 29
VLRX 4 - 50 F 335 245 580 170 203 31
3/8"
VLRX 4 - 60 F 362 245 607 170 203 32
n˙4 holes Ø 18
VLRX 4 - 80/7 F 435 255 690 180 205 39
VLRX 4 - 80 F 435 255 690 180 205 39
100
140
32
78
31
VLRX 8
TABLE OF HYDRAULIC PERFORMANCE
VLRX 8
50 Hz
32
VLRX 8
PUMP PERFORMANCE
Motor 50 100 150 175 200
Power L/1'
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW m /h 3 6 9 10,5 12
E4730010 VLRX 8 - 20 F M 1 ~ 230 V 5,2 25
1 0,75 21 20 18 15 13
E4730020 VLRX 8 - 20 F T 3 ~ 230 ÷ 400 V 3,3-1,9
E4730030 VLRX 8 - 30 F M 1 ~ 230 V 8 35
1,5 1,1 32 30 27 23 19
E4730040 VLRX 8 - 30 F T 3 ~ 230 ÷ 400 V 4,3-2,5
E4730050 VLRX 8 - 40 F M 1 ~ 230 V 12 45
2 1,5 42 40 35 30 26
E4730060 VLRX 8 - 40 F T 3 ~ 230 ÷ 400 V 5,9-3,4
Discharge head
E4730090 VLRX 8 - 80 F T 4 3 3 ~ 230 ÷ 400 V 11,8-6,8 85 80 70 60 52
in meters
E4730100 VLRX 8 - 100 F T 3 ~ 230 ÷ 400 V 16,8-9,7
5,5 4 106 100 88 76 65
E4730110 VLRX 8 - 100 F T 3 ~ 400 ÷ 690 V
E4730120 VLRX 8 - 120 F T 3 ~ 230 ÷ 400 V 16,8-9,7
5,5 4 127 119 104 90 77
E4730130 VLRX 8 - 120 F T 3 ~ 400 ÷ 690 V
E4730140 VLRX 8 - 140 F T 3 ~ 230 ÷ 400 V 21,5-12,4
7,5 5,5 149 130 122 105 92
E4730150 VLRX 8 - 140 F T 3 ~ 400 ÷ 690 V
E4730160 VLRX 8 - 160 F T 3 ~ 230 ÷ 400 V 21,5-12,4
7,5 5,5 171 160 138 120 104
E4430170 VLRX 8 - 160 F T 3 ~ 400 ÷ 690 V
E4730180 VLRX 8 - 180 F T 3 ~ 230 ÷ 400 V 28-16,4
10 7,5 193 181 160 135 120
E4730190 VLRX 8 - 180 F T 3 ~ 400 ÷ 690 V
E4730200 VLRX 8 - 200 F T 3 ~ 230 ÷ 400 V 28-16,4
10 7,5 214 200 175 153 132
E4730210 VLRX 8 - 200 F T 3 ~ 400 ÷ 690 V
VERSIONS AVAILABLE :
- “F” : in line ports with round flanges. ❷ Version with round flanges
Counterflanges on request PN10 DIN 2534/ISO 7005-2
- “V” ( on request ) : with 2” couplings for “VICTAULIC” joint. ❷
H
ØD
B1
Ø D3
L2
A2
Net
Dimensions (mm) Weight
Model (kg)
80
A B L D H D3
VLRX 8 - 20 F 245 237 422 160 131 - 33 130
190
VLRX 8 - 30 F 375 237 612 160 131 - 35 280
VLRX 8 - 40 F 420 265 685 185 130 - 43
VLRX 8 - 50 F 450 265 715 185 130 - 45
Ø19
VLRX 8 - 60 F 480 265 745 185 130 - 46
VLRX 8 - 80 F 545 315 860 200 140 - 54
VLRX 8 - 100 F 605 335 940 200 140 - 55
Ø86,5
Ø110
Ø150
Ø48
33
VLRX 16
TABLE OF HYDRAULIC PERFORMANCE
VLRX 16
50 Hz
34
VLRX 16
PUMP PERFORMANCE
Nominal
Power L/1' 100 200 250 300 350
CODE MODEL VOLTAGE Amp. Q
HP kW m /h
3
6 12 15 18 21
Discharge head
E5730090 VLRX 16 - 70 F T 3 ~ 230 ÷ 400 V 28-16,4
10 7,5 101 95 90 80 67
in meters
E5730100 VLRX 16 - 70 F T 3 ~ 400 ÷ 690 V
E5730110 VLRX 16 - 80 F T 3 ~ 230 ÷ 400 V 28-16,4
10 7,5 116 108102 92 76
E5730120 VLRX 16 - 80 F T 3 ~ 400 ÷ 690 V
E5730130 VLRX 16 - 100 F T 3 ~ 230 ÷ 400 V 40-23,5
15 11 145 136130 118 98
E5730140 VLRX 16 - 100 F T 3 ~ 400 ÷ 690 V
E5730150 VLRX 16 - 120 F T 3 ~ 230 ÷ 400 V 40-23,5
15 11 174 163156 140118
E5730160 VLRX 16 - 120 F T 3 ~ 400 ÷ 690 V
E5730170 VLRX 16 - 140 F T 3 ~ 230 ÷ 400 V 50-29
20 15 204 190184 163140
E5730180 VLRX 16 - 140 F T 3 ~ 400 ÷ 690 V
E5730190 VLRX 16 - 160 F T 3 ~ 230 ÷ 400 V 50-29
20 15 232 220208 188159
E5730200 VLRX 16 - 160 F T 3 ~ 400 ÷ 690 V
VERSIONS AVAILABLE : H
- “F” : in line ports with round flanges. Ø D
Counterflanges on request
- “V” ( on request ) : with 2” couplings for “VICTAULIC” joint.
B
Ø D3
L
VLRX
35
ACCESSORIES FOR VLR / VLRX / VLRI
VICTAULIC CONNECTIONS
DIMENSIONS
CODE DESCRIPTION MATERIAL CONNECTION
X Y Z
ZA009020 68 117 45 1” 1/4
42,2
ROUND FLANGES PN 16
B
CODE DESCRIPTION MATERIAL ext. inter. Hole No. F To be SPEC
D S Threaded. welded
D3086KKK 140 100 18 1”1/4 - UNI
4 2254
S
F
B7098KKK 150 110 4 18 - DN40 UNI
2282
B7097KKK 150 110 4 18 1”1/2 - UNI
2254
B UNI
ZB901890 165 125 4 18 - DN50 2282
STEEL
B7050KKK 165 125 4 18 2” - UNI
2254
B7075KKK 185 145 4 18 - DN65 UNI
D 2282
B7051KKK 165 125 4 18 2”1/2 - N/A
Kit including 2 oval
ZB901920 flanges, bolts 220 180 8 18 - DN100 UNI
2282
and gaskets STAINLESS 140 99,2 20 1”1/4 DN32
ZA008460 4 N/A
STEEL
ZB902120 150 110 4 20 1”1/2 DN40 N/A
AISI 316
ZB902130 165 126 4 20 2” DN50 N/A
OVAL FLANGES
D holes B
CODE DESCRIPTION MATERIAL ext. ext. inter.
D A S F Threaded
Single oval flange
CAST 95 68 11 1”
S
ZC001270 65
F
IRON
B A CAST 95 68 11 1”1/4
ZC001290 65
IRON
D CAST
ZC001280 128 75 100 14 1”1/2
IRON
STAINLESS
Kit including 2 oval
STEEL
ZA008560 flanges, bolts 95 68 65 11 1”1/4
stamped
and gaskets
AISI 316
SELECTION TABLE
ACCESSORY KIT N. 2 CIRCULAR FLANGES OVAL FLANGES
B Dimension 11/4” 11/2” DN 40 2” 2 1/2” DN 50 DN 65 DN 100 DN 32 1” 1 1/4” 1 1 /2 ” 1 1/4 ”
PN 16 PN 16 PN 16 PN 16 - PN 25 PN 16 PN 16 PN 16 CAST CAST CAST AISI 316
Notes IRON IRON IRON
D3086KKK
B7097KKK
B7098KKK
B7050KKK
B7051KKK
B7075KKK
ZC001270
ZC001290
ZC001280
ZB901890
ZB901920
ZA008460
ZA008560
CODE
* * *
TYPE
VLR 2B FLANGE A
VLR 2B FLANGE F
VLR 4 FLANGEA
VLR 4 FLANGE F
VLR 8 FLANGE A
VLR 8 FLANGE F
VLR 16 FLANGE F
VLR 30B FLANGE F
VLR 60B FLANGE F
VLRX 2B FLANGE A
VLRX 2B FLANGE F
VLRX 4 FLANGE A
VLRX 4 FLANGE F
* These codes refer to the bare single flange, without bolts and gaskets
The accessory is included in the pump as a standard The accessory is optional
36
MULTINOX VE
MULTISTAGE CENTRIFUGAL PUMPS
Applications Motor
- Pumping and distribution of water in - Enclosed, externally ventilated
domestic systems used on a - Level of protection IP 44.
continuous or intermittent basis - Class F insulation.
- Booster systems - Single phase power supply with
- Washing systems, garden irrigation, capacitor.
fountains. Permanently activated and thermal
- Firefighting systems protection built into the motor
winding.
- Three phase power supply with
external protection provided by the
user.
- Speed of rotation 2850 rpm.
- Suitable for continuous use.
MULTINOX 200/110 T
Usage limitations
- Type of liquid: clean water with no
suspended solids or abrasive material
- Maximum liquid temperature 50°C
- Maximum recommended suction
height 6 m with foot valve
- Maximum operating pressure:
9 bar
12bar (MULTINOX VE 200/110)
11
10
DESIGN FEATURES
9
7
Component Material
6
1 Outer liner (pump body) X5 CrNi 1810 ( Aisi 304 ) Stainless steel
8 2 Suction flange EN GJL 200 ( ex G20 ) Cast iron
3 Impeller Technopolymer with AISI 304 stainless steel shim ring
4 Diffuser Technopolymer
5 Shaft (hydraulic end) X5 CrNi 1810 (Aisi 304) Stainless steel
1
6 Mechanical seal Graphite
5 7 Counterface Ceramic
4 8 O'ring NBR 70 shore
3
9 Discharge flange EN GJL 200 ( ex G20 ) Cast iron
8 Motor bracket
2 10 Adapter EN GJL 200 (ex G20) Grey cast iron
on model 200/110
11 Motor joint EN GJS 400 (ex GS400) Nodular cast iron on model 200/110
38
MULTINOX VE
TABLE OF HYDRAULIC PERFORMANCE
110
200/1
10
100
90
200/90
80
200/8
0
70
200/65
60
50 200/52
40 200/40
30
20
10
Hm
L / 1' 40 80 120 160 200
Q
m3/ h 2,4 4,8 7,2 9,6 12
PUMP PERFORMANCE
Nominal Absorbed
Power Power L/1' 20 40 80 120 160
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW m /h 1,2 2,4 4,8 7,2 9,6
N4194010-B MULTINOX-VE 200/40 M 1 ~ 220÷240 V 7 20
1,5 1,1 2 1,5 38 37 32 24 12
N4194020-B MULTINOX-VE 200/40 T 3 ~ 230÷400 V 3,6-2,1
N4194030-B MULTINOX-VE 200/52 M 1 ~ 220÷240 V 8,5 25
1,8 1,3 2,5 1,8 50 49 42 32 18
Discharge head
N4194090 MULTINOX-VE 200/110 T 3,5 2,6 4,4 3,2 3 ~ 230÷400 V 10-5,6 107 103 90 68 35
MULTINOX-VE 200/40 438 115 37 143 204 1" 1/4 1" 1/4 19
MULTINOX-VE 200/52 466 115 37 174 204 1" 1/4 1" 1/4 21
MULTINOX-VE 200/65 504 115 37 203 204 1" 1/4 1" 1/4 23
MULTINOX-VE 200/80 525 115 37 230 204 1" 1/4 1" 1/4 25
MULTINOX-VE 200/90 555 115 37 257 204 1" 1/4 1" 1/4 27
MULTINOX-VE 200/110 760 115 37 320 204 1" 1/4 1" 1/4 36
39
DHR
MULTISTAGE CENTRIFUGAL PUMPS
The DHR series pumps are horizontal, multistage, centrifugal and no self
priming. All the rotating parts in contact with the pumped liquid are in
stainless steel.
Applications
- Pumping and distribution of water in
domestic systems used on a
continuous or intermittent basis
- Booster systems
DHR 9 - Washing systems, garden irrigation,
fountains
2 4 3 5 6 1
DESIGN FEATURES
Component Material
1 Motor bracket EN GJL 200 (ex G20) cast iron
2 Suction flange EN GJL 200 (ex G20) cast iron
3 Impeller X5 CrNi 1810 (AISI 304) Stainless steel
4 Diffuser X5 CrNi 1810 (AISI 304) Stainless steel
5 Shaft X2 CrNiMo 17-12 (AISI 316) Stainless steel
on DHR 2 and DHR 4.
X5 CrNi 1810 (AISI 304) Stainless steel on DHR 9
6 Mechanical seal Graphite/Ceramic
40
DHR
TABLE OF HYDRAULIC PERFORMANCE
DHR 23 /25
50 Hz
PUMP PERFORMANCE
Nominal Absorbed
Power Power L/1 10 20 30 40 50
CODE MODEL VOLTAGE Amp. µF. Q
HP kW HP kW m3/ 0,6 1,2 1,8 2,4 3
E0502103 DHR 23 M 0,5 0,37 0,65 0,48 1 ~ 230 V 2,4 14
DHR
Discharge 28 26 23 19 15
E0501003 DHR 23 T 0,5 0,37 0,62 0,46 3 ~ 230 ÷ 400 V 1,75 - 1
head
E0502105 DHR 25 M 0,75 0,55 0,98 0,725 1 ~ 230 V 3,8 16 in meters
44 42 37 32 25
E0501005 DHR 25 T 0,75 0,55 0,95 0,7 3 ~ 230 ÷ 400 V 2,45 - 1,4
41
DHR
TABLE OF HYDRAULIC PERFORMANCE
DHR 42 /43 / 44
45 / 46
50 Hz
PUMP PERFORMANCE
Nominal Absorbed
Power Power L/1' 40 60 80 100 120
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW m /h 2,4 3,6 4,8 6 7,2
E1502102 DHR 42 M 0,5 0,37 0,73 0,54 1 ~ 230 V 2,6 14
16 14 12 9 7
E1501002 DHR 42 T 0,5 0,37 0,7 0,52 3 ~ 230 ÷ 400 V 1,9 - 1,1
E1502103 DHR 43 M 0,75 0,55 1 0,75 1 ~ 230 V 3,9
Discharge head
16 23 20 17 14 10
E1501003 DHR 43 T 0,75 0,55 0,99 0,73 3 ~ 230 ÷ 400 V 2,6 - 1,5
in meters
42
DHR
43
DHR
TABLE OF HYDRAULIC PERFORMANCE
H
(m)
65 P
DHR9/60 (MPa)
DHR9
60 50Hz 0,6
55
DHR9/50
50 0,5
45
DHR9/40
40 0,4
35
DHR9/30
30 0,3
25
DHR9/20
20 0,2
15
10 0,1
P1 0
(kW
ass.) 3,00 DHR9/60
2,50 DHR9/50
2,00 DHR9/40
1,50
DHR9/30
1,00
DHR9/20
0,50
PUMP PERFORMANCE
Nominal Absorbed
Power Power L/1' 40 80 120 160 200 240 260
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW m /h 2,4 4,8 7,2 9,6 12 14,4 15,6
E9502102 DHR9 - 20 M 0,87 0,65 1,34 1 1 ~ 230 V 4,5 20
20 18,5 16,3 13,2 9,2 4,5 2,5
E9501002 DHR9 - 20 T 0,87 0,65 1,21 0,9 3 ~ 230 ÷ 400 V 3 - 1,7
Discharge head
E9502103 DHR9 - 30 M 1,27 0,95 1,88 1,4 1 ~ 230 V 6 25 31 29,3 25,8 21,3 15,6 9 4,7
E9501003 DHR9 - 30 T 1,27 0,95 1,81 1,35 3 ~ 230 ÷ 400 V 4,4 - 2,5
in meters
E9502104 DHR9 - 40 M 1,74 1,3 2,41 1,8 1 ~ 230 V 8 31,5 40 37,5 33 27 19 10 5,1
E9501004 DHR9 - 40 T 1,74 1,3 2,15 1,6 3 ~ 230 ÷ 400 V 5,3 - 3
E9502105 DHR9 - 50 M 2,15 1,6 2,95 2,2 1 ~ 230 V 10 35 50,6 48,5 43 35,5 26 14 6
E9501005 DHR9 - 50 T 2,15 1,6 2,68 2 3 ~ 230 ÷ 400 V 6,1 - 3,5
E9501006 DHR9 - 60 T 2,55 1,9 3,35 2,5 3 ~ 230 ÷ 400 V 7,9 - 4,5 60 55,7 49 40,1 28,8 14,4 6,1
44
DHR
DHR 9 - 50 T 438 196 185 105 168 160 1”1/2 1”1/4 22,5
DHR
DHR 9 - 50 M 438 227 185 105 168 160 1”1/2 1”1/4 23,5
DHR 9 - 60 T 468 196 185 105 198 160 1”1/2 1”1/4 24,1
45
DHI
MULTISTAGE CENTRIFUGAL
PUMPS IN AISI 316 STAINLESS STEEL
The DHI series horizontal multistage centrifugal pumps offer the following benefits:
- High hydraulic pressure and flow rate performance
- Minimum electrical energy consumption
- Extremely silent operation
Applications
- Aggressive liquids transfer
- Pumping and distribution of water in
domestic systems used on a
continuous or intermittent basis
- Booster systems
- Washing systems, garden irrigation,
fountains
1 3 4 5 6 7 8 2
DESIGN FEATURES
Component Material
1 Pump casing AISI 316 Stainless steel
2 Motor bracket Die-cast aluminium
3 Impeller X CrNiMo 17-12-03 (AISI 316) Stainless steel
4 Intermediate chamber X CrNiMo 17-12-03 (AISI 316) Stainless steel
5 Motor shaft X CrNiMo 17-12-03 (AISI 316) Stainless steel
6 Mechanical seal Graphite
7 Counterface Ceramic
8 Seal holder plate X CrNiMo 17-12-03 (AISI 316) Stainless steel
O'ring EPDM rubber
46
DHI
TABLE OF HYDRAULIC PERFORMANCE
DHI 24 / 26 / 27
50Hz
PUMP PERFORMANCE
Nominal Absorbed
Power Power L/1' 10 20 30 40 50 60
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW m /h 0,6 1,2 1,8 2,4 3 3,6
N4221000 DHI 24 M 1 ~ 230 V 3,4 16
Discharge head
47
DHI
TABLE OF HYDRAULIC PERFORMANCE
DHI 43 / 44 / 45
50 Hz
PUMP PERFORMANCE
Nominal Absorbed
Power Power L/1' 40 60 80 100 120
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW m /h 2,4 3,6 4,8 6 7,2
48
DHI
A1 B1 C1 D1 E1 DNA DNM kg
49
AP
DEEP SUCTION SELF-PRIMING PUMPS
COMPLETE WITH EJECTOR
The JET AP 800, AP 1000 pumps are suitable for deep suction from wells with a
minimum diameter of 4" using a recirculation system.
Applications
- Pumping and distribution
- Booster systems
Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with
capacitor permanently activated and
thermal protection built into the
motor winding
Usage limitations - Three phase power supply with
external protection provided by the
- Type of liquid: clean water with no user
suspended solids or abrasive material - Speed of rotation 2850 rpm
- Maximum liquid temperature 50°C - Suitable for continuous use
- Maximum recommended suction
height with foot valve:
AP 800 = 30m AP 1000 = 35m
- Maximum operating pressure 6 bar
DESIGN FEATURES
Component Material
1 Pump casing Cast iron
2 Motor bracket Cast iron
3 Diffusors Technopolymer
4 Impeller Technopolymer
5 Venturi tube and nozzle Technopolymer
6 Shaft Stainless steel
7 Mechanical seal Graphite
8 Counterface Ceramic
50
AP
PUMP PERFORMANCE
Nominal Absorbed
power Power L/1' 10 15 20 25 30 35
CODE MODEL VOLTAGE Amp. µF. Max Ejector Suction Q
HP kW HP kW Suction Type 3
m /h 0,6 0,9 1,2 1,5 1,8 2,4
m
15 35 22 11
N20
20 21 10
N4176630 AP 800 M 1 0,75 1,3 1 1 ~ 220 ÷ 240 V 4,5 12,5 30
25 22 16 11 6
N30
Discharge
in meters
30 15 10 5
head
15 49 33 22 11
N20
20 31 19 10
N4173030 AP 1000 M 1,36 1 1,5 1,1 1 ~ 220 ÷ 240 V 5 16 35 25 27 22 16 11 6
N30 30 19 16 10 6
35 14 10 5
51
MCX
MULTISTAGE CENTRIFUGAL PUMPS
The MCX series horizontal multistage centrifugal pumps offer the following benefits:
- High hydraulic pressure and flow rate performance
- Minimum electrical energy consumption
- Extremely silent operation
Applications
- Pumping and distribution of water in
domestic systems
- Booster systems
- Firefighting systems
- Washing systems, irrigation
10 9 8 DESIGN FEATURES
Component Material
1 Pump casing X5 CrNi 1810 (AISI 304) Stainless steel
2 Motor bracket Die-cast aluminium
52
MCX
TABLE OF HYDRAULIC PERFORMANCE
60
50
40
30
20
10
Hm
L / 1' 10 20 30 40 50 60 70 80
Q
m3/ h 0,6 1,2 1,8 2,4 3 3,6 4,2 4,8
PUMP PERFORMANCE
Nominal Absorbed
Power Power L/1 0 20 40 60 80
CODE MODEL VOLTAGE Amp. µF. Q
HP kW HP kW m3/ 0 1,2 2,4 3,6 4,8
N4201180-B MCX 80/36 M 1 ~ 230 V 2,9 12,5
Discharge head
53
MCX
TABLE OF HYDRAULIC PERFORMANCE
60
50
40
30
20
10
Hm
L / 1' 20 40 60 80 100 120
Q
m3/ h 1,2 2,4 3,6 4,8 6 7,2
PUMP PERFORMANCE
Nominal Absorbed
Power Power L/1 0 20 40 60 80 100
CODE MODEL VOLTAGE Amp. µF. Q
HP kW HP kW m3/ 0 1,2 2,4 3,6 4,8 6
N4201210-B MCX 120/36 M 1 ~ 230 V 3,5 12,5
Discharge head
54
MCX
TABLE OF HYDRAULIC PERFORMANCE
70
60
50
40
30
20
10
Hm
L / 1' 20 30 40 60 80 100 120 140 160 180 200
Q
m3/ h 1,2 1,8 2,4 3,6 4,8 6,0 7,2 8,4 9,6 10,8 12
PUMP PERFORMANCE
Nominal Absorbed
Power Power L/1' 0 20 40 80 120 160 200
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW m /h 0 1,2 2,4 4,8 7,2 9,6 12
N4201360-B MCX 200/40 M 1 ~ 230 V 7 20
Discharge head
MCX 200/40 105 400 141 235 205 1" 1/4 1" 1/4 14
MCX
MCX 200/52 105 430 141 235 205 1" 1/4 1" 1/4 16
MCX 200/65 105 460 141 235 205 1" 1/4 1" 1/4 18
55
MULTINOX
MULTISTAGE CENTRIFUGAL PUMP
The horizontal multistage centrifugal MULTINOX pumps are suitable for developing a
considerable pressure and flow rate with extremely silent operation and with a minimum
electrical energy consumption.
Applications
– Pumping and distribution of water
in domestic systems.
– Booster systems.
– Firefighting systems .
– Washing systems.
– Irrigation
2 6 5 1 4 7 3
DESIGN FEATURES
Component Material
1 Outer liner (pump body) X5 CrNi 1810 (AISI 304) Stainless steel
2 Suction flange EN GJL 200 (ex G20) Cast iron
3 Motor bracket EN GJL 200 (ex G20) Cast iron
4 Impeller Technopolymer with stainless steel shim ring
5 Diffuser Technopolymer
6 Shaft (hydraulic end) X5 CrNi 1810 (AISI 304) Stainless steel
7 Mechanical seal Graphite/Ceramic
56
MULTINOX
TABLE OF HYDRAULIC PERFORMANCE
70
60
120/
60
50
120/4
8
40
80/
60
30
80/4
8
20 80/3
6
10
0
L / 1' 10 20 30 40 50 60 70 80 90 100 110
Q
m3/ h 0,6 1,2 1,8 2,4 3 3,6 4,2 4,8 5,2 6,0 7,2
PUMP PERFORMANCE
Nominal Absorbed
power power L/1' 0 20 40 60 80 100
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW m /h 0 1,2 2,4 3,6 4,8 6
N4184070-B MULTINOX 80/36M 0,60 0,45 0,9 0,65 1 ~ 230 V 3 12,5
33 28 22 15 7
N4184090-B MULTINOX 80/36T 0,60 0,45 0,9 0,65 3 ~ 230 ÷ 400 V 2,3-1,3
N4184080-B MULTINOX 80/48M 0,75 0,55 1,1 0,8 1 ~ 230 V 3,8 12,5 43 37 29 20 9
Discharge head
N4184100-B MULTINOX 80/48T 0,75 0,55 1,1 0,8 3 ~ 230 ÷ 400 V 2,7-1,6
in meters
A B C D E DNA DNM kg
MULTINOX 80/36 343 158 148 126 130 1" 1" 9,5
MULTINOX 80/48 389 176 171 126 138 1" 1" 11,7
MULTINOX 80/60 411 175 193 126 138 1" 1" 13,7
MULTINOX 120/48 389 175 171 126 138 1" 1" 13,1
MULTINOX 120/60 411 175 193 126 138 1" 1" 13,7
57
MAX
SELF-PRIMING MULTISTAGE CENTRIFUGAL PUMPS
The MAX horizontal multistage centrifugal pumps combine the functional benefits
of centrifugal pumps and the practical benefits of self priming pumps
They warrant high hydraulic and suction performances.
Wired version
Applications
- Pumping and distribution of water
in domestic systems
- Booster systems
- Firefighting systems
- Washing systems, irrigation
9 10
DESIGN FEATURES
Component Material
1 Pump casing X5 CrNi 1810 (AISI 304) Stainless steel
2 Motor bracket Die-cast aluminium
58
MAX
TABLE OF HYDRAULIC PERFORMANCE
60
50
40
30
20
10
Hm
L / 1' 10 20 30 40 50 60 70 80
Q
m3/ h 0,6 1,2 1,8 2,4 3 3,6 4,2 4,8
PUMP PERFORMANCE
Nominal Absorbed
power Power L/1' 0 20 40 60 80
CODE MODEL VOLTAGE Amp. µF. Q
HP kW HP kW m3/h 0 1,2 2,4 3,6 4,8
N4501030-B MAX 80/48 M 1 ~ 230 V 4 12,5
0,75 0,55 1,1 0,8 Discharge 45 36 28 17 1
N4501070-B MAX 80/48 T 3 ~ 230 ÷ 400 V 2,6-1,5
head
N4501040-B MAX 80/60 M 1 ~ 230 V 4,8 16 in meters
1 0,75 1,3 1 57 50 40 27 3
N4501080-B MAX 80/60 T 3 ~ 230 ÷ 400 V 2,9-1,7
59
MAX
TABLE OF HYDRAULIC PERFORMANCE
60
50
40
30
20
10
Hm
L / 1' 20 40 60 80 100 120
Q
m3/ h 1,2 2,4 3,6 4,8 6 7,2
PUMP PERFORMANCE
Nominal Absorbed
Power Power L/1' 0 20 40 60 80 100
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW m /h 0 1,2 2,4 3,6 4,8 6
N4501050-B MAX 120/48 M 1 ~ 230 V 4,6
1 0,75 1,5 1,1 16 48 42 37 27 18 5
Discharge
in meters
60
MULTINOX-A
SELF-PRIMING MULTISTAGE CENTRIFUGAL PUMPS
Applications
- Pumping and distribution of water in
domestic systems used on a
continuous or intermittent basis
- Booster systems
- Washing systems, garden irrigation,
fountains
DESIGN FEATURES
2 4 3 1 6 7 9 5 Component Material
1 Outer liner (pump body) X5 CrNi 1810 (AISI 304) Stainless steel
2 Suction flange EN GJL 200 (ex G20) Cast iron
3 Impeller Technopolymer with AISI 304 stainless steel shim ring
4 Diffusor Technopolymer
5 Shaft (hydraulic end) X5 CrNi 1810 (AISI 304) Stainless steel
6 Mechanical seal Graphite
7 Counterface Ceramic
8 O'ring NBR 70 shore
8 9 Discharge flange EN GJL 200 (ex G20) Cast iron
Motor bracket
61
MULTINOX-A
TABLE OF HYDRAULIC PERFORMANCE
80
70
60
50
40
30
20
10
Hm
L / 1' 40 80 120 160 200
Q
m3/ h 2,4 4,8 7,2 9,6 12
PUMP PERFORMANCE
Nominal Absorbed
Power Power L/1' 20 40 80 120 160
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW m /h 1,2 2,4 4,8 7,2 9,6
N418A010-B MULTINOX-A 200/40 M 1,5 20
1,1 2 1,5 1 ~ 220÷240 V 7
38 37 32 24 12
N418A020-B
Discharge head
MULTINOX 200/40 441 200 188 155 170 1" 1/4 1" 1/4 19
MULTINOX 200/52 469 200 215 155 170 1" 1/4 1" 1/4 21
MULTINOX 200/65 497 200 243 155 170 1" 1/4 1" 1/4 23
MULTINOX 200/80 525 200 270 155 170 1" 1/4 1" 1/4 25
62
JET
SELF-PRIMING CAST IRON PUMPS
The JET series self-priming pumps combine the functional benefits of centrifugal
pumps and the practical benefits of self-priming pumps.
The Venturi system the pumps are fitted with guarantees optimum hydraulic
efficiency and considerable pressure capacity.
Applications
- Pumping and distribution of water in
domestic systems used on a
continuous or intermittent basis
- Booster systems
- Washing systems, garden irrigation,
fountains
- Pumping from wells or tanks
DESIGN FEATURES
Component Material
NEW JET JET
Pump casing EN GJL (ex G20) Cast iron EN GJL (ex G20) Cast iron
Motor bracket Aluminium EN GJL (ex G20) Cast iron
Technopolymer with Technopolymer
X5 CrNi 1810 (AISI 304) models 600-800-1000
Impeller Pressed brass alloy
Stainless steel shim ring
models 100-160-800-1000
Diffusor venturi Monobloc assembly: Technopolymer
tube and nozzle Technopolymer
X12 CrNiS 1809 (AISI 416) X12 CrNiS 1809 (AISI 416)
Motor shaft
Stainless steel Stainless steel
Mechanical seal Graphite Graphite
Counterface Ceramic Ceramic
O-ring NBR 70 shore NBR 70 shore
63
JET
TABLE OF HYDRAULIC PERFORMANCE
50
40
30 60/
50
45
/43
20 40
/40
10
Hm
L / 1' 10 20 30 40 50 60 70 80
Q
m3/ h 0,6 1,2 1,8 2,4 3 3,6 4,2 4,8
PUMP PERFORMANCE
Nominal Absorbed
Power Power L/1' 0 10 20 30 40 50 60 70
CODE MODEL VOLTAGE Amp. µF. Q
HP kW HP kW m3/h 0,6 1,2 1,8 2,4 3 3,6 4,2
N4176580 NEWJET 60/50 M 0,75 0,55 1,1 0,8 1 ~ 220 ÷ 240 V 4 12,5 46 36 31 26 18 6
64
JET
TABLE OF HYDRAULIC PERFORMANCE
50
40
30
20
10
Hm
L / 1' 10 20 30 40 50 60 70 80
Q
m3/ h 0,6 1,2 1,8 2,4 3 3,6 4,2 4,8
PUMP PERFORMANCE
Nominal Absorbed
Power Power L/1' 0 5 20 30 40 50 60 70
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW m /h 0 0,3 1,2 1,8 2,4 3 3,6 4,2
N4171010 JET 600 M 1 ~ 220 ÷ 240 V 3,2 8
0,8 0,6 0,9 0,7 43 40 30 24 17
N4171020 JET 600 T 3 ~ 230 ÷ 400 V 1,9-1,1
N4176550 JET 800 M 1 ~ 220 ÷ 240 V 4,5 12,5
1 0,75 1,3 1 48 46 39 33 27 8
Discharge head
JET 800 400 147 160 190 182 1" 1" 14,2
JET 1000 425 147 160 190 182 1" 1" 16,8
65
JET
TABLE OF HYDRAULIC PERFORMANCE
80
70
60
50
40
30
20
10
Hm
L / 1' 20 40 60 80 100 120 140 160
Q
m3/ h 1,2 2,4 3,6 4,8 6 7,2 8,4 9,6
PUMP PERFORMANCE
Nominal Absorbed L/1' 5 20 40 60 80 100 120 140
Power Power
CODE MODEL VOLTAGE Amp. µF. Q
HP kW HP kW m3/h 0,3 1,2 2,4 3,6 4,8 6 7,2 8,4
N4175010 JET 100/50 M 1 ~ 230 V 7,4 35
1,5 1,1 2,2 1,6 50 45 40 35 32 27
N4175020 JET 100/50 T 3 ~ 230 ÷ 400 V 5-2,5
N4175030 JET 100/68 M 1 ~ 230 V 10,5 40
2 1,5 2,7 2 65 60,5 55 48 43 35
Discharge head
N4175050 JET 100/80 T 3 2,2 3,4 2,5 3 ~ 230 ÷ 400 V 8,2-4,8 77 70,5 65 58 52 45
N4175100 JET 160/60 T 3 2,2 3,4 2,5 3 ~ 230 ÷ 400 V 9,2-5,3 60 58 54,5 51 47 44 40 38
66
JETINOX
SELF-PRIMING STAINLESS STEEL PUMPS
The JETINOX series self-priming pumps combine the functional benefits of centrifugal
pumps and the practical and qualitative benefits of self-priming pumps.
The Venturi system the pumps are fitted with guarantees optimum hydraulic efficiency
and considerable pressure capacity.
• SELF-PRIMING
• HIGH SUCTION CAPACITY
Applications
- Pumping and distribution of water in
domestic systems used on a continuous
or intermittent basis
- Booster systems
- Washing systems, garden irrigation,
fountains
- Pumping from wells or tanks
Usage limitations
Wired version
- Type of liquid: clean water with no
suspended solids or abrasive material
- Maximum liquid temperature 50°C
Motor - Maximum recommended suction height
8m with foot valve
- Enclosed, externally ventilated - Maximum operating pressure 6 bar
- Level of protection IP 44
- Class F insulation
- Single phase power supply with
capacitor permanently
activated
- Thermal protection built into the motor
winding
- Speed of rotation 2850 rpm
- Suitable for continuous use
DESIGN FEATURES
Component Material
1 Pump casing X5 CrNi 1810 (AISI 304) Stainless steel
2 Motor bracket Die-cast aluminium
1 9 8 5
9 3 Impeller Technopolymer with stainless steel shim ring
4 Monobloc diffusor Venturi Technopolymer
tube nozzle assembly
5 Shaft X12 CrNiS 1809 (AISI 416) Stainless steel
6 Mechanical seal Graphite
7 Counterface Ceramic
Technopolymer (models 45-60-70)
4 3 6 7 2 8 Seal holder plate X5 CrNi 1810 (AISI 304) Stainless steel (model 90)
9 O-ring NBR 70 Shore
67
JETINOX
TABLE OF HYDRAULIC PERFORMANCE
60
50
40
30
60
45 /50 70
/43 /50 90
/43
90
20
/50
10
Hm
L / 1' 20 40 60 80 100 120
Q
m3/ h 1,2 2,4 3,6 4,8 6 7,2
PUMP PERFORMANCE
Nominal Absorbed
power power L/1' 0 10 20 30 40 50 60 70 80
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW (V) m /h 0,6 1,2 1,8 2,4 3 3,6 4,2 4,8
N4176190 JETINOX 45/43 M 0,5 0,37 0,8 0,6 1 ~ 220÷240 V 3 8 43 30 23 16 1
Discharge head
68
NRM
CLOSE-COUPLED CENTRIFUGAL PUMPS (2 - 4 Poles)
69
NRM
CLOSE-COUPLED CENTRIFUGAL PUMPS (2 - 4 Poles)
The NRM series is made up of single stage electric monobloc pumps with a flanged
hydraulics/motor connection.
The pump casing is manufactured in accordance with the provisions of EN733/DIN24255.
The pumps may be installed in all positions, except where the suction port is directed
upwards
Applications
- Air conditioning and heating systems
- Pumping of water from lakes,
watercourses, wells
- Overhead or surface irrigation
- Water supply systems.
- Boosting and firefighting systems.
DESIGN FEATURES
Component Material
1 Pump casing EN GJL 200 ( ex G20 ) Cast iron
2 Motor bracket EN GJL 200 ( ex G20 ) Cast iron
3 Impeller EN GJL 200 ( ex G20 ) Cast iron
4 Shaft AISI 420 stainless steel
5 Mechanical seal Silicum carbide/Silicum carbide
70
NRM2
Performance range
2 POLES
H
(m)
150
100
80 65x50
50x32x250 x250
60
65x40 80x65x250
x250 100x80
50 x200
50x32x200
80x65x200
65x40 65x50
40 x200 x200
100x80 125x100
x160 x200
30
50x32x160 65x40 65x50 80x65x160
x160 x160
100x80
x125
20
50x32x125 65x40 65x50
x125 80x65x125
x125
10
0
40 100 200 400 1000 2000 4000
Q:(L/min)
NRM
71
NRM2 50X32
PUMP PERFORMANCE
Nominal L/1' 100 125 150 175 200 225 250 275 300 350 400
Power VOLTAGE Amp. Q
CODE MODEL
HP kW
(V) 3 X 400 V m3/h 6 7,5 9 10,5 12 13,5 15 16,5 18 21 24
AT07003 NRM2 50X32X125C 1 0,75 220/380 3,3/1,9 15,5 14,5 13,5 12,5 11,5 10,3 21,5 7,5 6
AT07005 NRM2 50X32X125B 1,35 1 220/380 4,2/2,4 20,5 20 19 18 17 16 15 13,5 11,5 7,5
AT07007 NRM2 50X32X125A 2 1,5 220/380 6,2/3,6 24,5 24 23,5 23 22 21 20 18,5 16,5 13
AT07011 NRM2 50X32X160C 2,7 2 220/380 7,7/4,4 28,5 28 27,5 26,5 25,5 24 23 21 20 15
AT07013 NRM2 50X32X160B 4 3 220/380 11/6,4 33,5 33 32,5 32 31 30 29 27,5 26 22,5
AT07015 NRM2 50X32X160A 4 3 220/380 11/6,4 38 37,5 37 36 35 34 33 31,5 30 26,5
220/380 15,2/8,8
Discharge head
AT07019 NRM2 50X32X200C
5,5 4 47 46,5 46 45 44 43 42 41 39,5 37,5 35
in meters
AT07020 NRM2 50X32X200C 380/415 8
AT07021 NRM2 50X32X200B 220/380 19,5/11,3
7,5 5,5 55 54,5 54 53,5 53 52 51 49,5 48 45 42
AT07022 NRM2 50X32X200B 380/415 11,3
AT07023 NRM2 50X32X200A 220/380 30/17,3
10 7,5 62 61,5 61 60 59 58 57 56 54 52,5 49
AT07024 NRM2 50X32X200A 380/415 17,3
n° d1 holes ø e1
DN
a1
b1
c1
Flange
UNI PN 16
DN a1 b1 c1 d1 e1
32 78 100 140 4 18
50 102 125 165 4 18
NRM2 50X32X125B 80 32 50 1 80 112 140 50 100 70 190 140 14 12 425 220 252 118 22
NRM2 50X32X125A 80 32 50 1 80 112 140 50 100 70 190 140 14 12 425 220 252 118 23,5
NRM2 50X32X160C 80 32 50 1 80 132 160 50 100 70 240 190 14 12 425 270 292 149 28
NRM2 50X32X160B 90 32 50 1 80 132 160 50 100 70 240 190 14 12 465 270 292 149 33
NRM2 50X32X160A 90 32 50 1 80 132 160 50 100 70 240 190 14 12 465 270 292 149 35
NRM2 50X32X200C 100 32 50 1 80 160 180 50 100 70 240 190 14 12 505 280 340 159 53,5
NRM2 50X32X200B 112 32 50 1 80 160 180 50 100 70 240 190 14 12 515 280 340 159 53
NRM2 50X32X200A 112 32 50 1 80 160 180 50 100 70 240 190 14 12 515 280 340 159 53
NRM2 50X32X250C 112 32 50 1 100 180 225 65 125 95 320 250 14 12 535 345 405 184 66
NRM2 50X32X250B 132 32 50 1 100 180 225 65 125 95 320 250 14 12 640 345 405 184 80
NRM2 50X32X250A 132 32 50 1 100 180 225 65 125 95 320 250 14 12 640 345 405 184 87
72
NRM2 65X40
PUMP PERFORMANCE
Nominal L/1' 250 275 300 350 400 450 500 550 600 650 700
Power VOLTAGE Amp. Q
CODE MODEL
HP kW
(V) 3 X 400 V 3
m /h 15 16,5 18 21 24 27 30 33 36 39 42
AT07035 NRM2 65X40X125C 2 1,5 220/380 6,2/3,6 15,5 15,3 15 14,1 13 11,8 10,5 9 7
AT07037 NRM2 65X40X125B 2,7 2 220/380 7,7/4,4 19 18,8 18,5 17,5 16,5 15,5 14,5 13 10,5
AT07039 NRM2 65X40X125A 4 3 220/380 11/6,4 24,5 24,3 24 23,5 23 22 20,5 19 17
Discharge head
AT07049 NRM2 65X40X200C 220/380 19,5/11,3
7,5 5,5 46 45 44 43 41,5 39 37 34 31
in meters
AT07050 NRM2 65X40X200C 380/415 11,3
AT07051 NRM2 65X40X200B 220/380 30/17,3
10 7,5 51 50,5 50 49 47,5 45 42,5 40 37
AT07052 NRM2 65X40X200B 380/415 17,3
AT07053 NRM2 65X40X200A 220/380 30/17,3
10 7,5 56,5 56 55,5 54,5 53 51 49 47 44
AT07054 NRM2 65X40X200A 380/415 17,3
AT07057 NRM2 65X40X250D 220/380 39/22,5
13,5 10 69 68,5 68 66,5 65 63 61 59 57 54
AT07058 NRM2 65X40X250D 380/415 22,5
AT07060 NRM2 65X40X250C 17 12,5 380/415 27 77 76,5 76 74,5 73 71 69 67 65 62,5 60
n° d1 holes ø e1
DN
a1
b1
c1
Flange
UNI PN 16
DN a1 b1 c1 d1 e1
40 88 110 150 4 18
65 122 145 185 4 18
NRM2 65X40X125B 80 40 65 1 80 112 140 50 100 70 210 160 14 12 425 425 252 149 25,5
NRM2 65X40X125A 90 40 65 1 80 112 140 50 100 70 210 160 14 12 465 255 252 149 30
NRM2 65X40X160B 90 40 65 1 80 132 160 50 100 70 240 190 14 12 465 280 292 159 30
NRM2 65X40X160A 100 40 65 1 80 132 160 50 100 70 240 190 14 12 505 280 292 159 40
NRM2 65X40X200C 112 40 65 1 100 160 180 50 100 70 265 212 14 12 535 300 340 159 54
NRM2 65X40X200B 112 40 65 1 100 160 180 50 100 70 265 212 14 12 535 300 340 159 54,5
NRM2 65X40X200A 112 40 65 1 100 160 180 50 100 70 265 212 14 12 535 300 340 159 54,5
NRM
NRM2 65X40X250D 132 40 65 1 100 180 225 65 125 95 320 250 14 12 640 280 405 184 77
NRM2 65X40X250C 132 40 65 1 100 180 225 65 125 95 320 250 14 12 640 280 405 184 85
NRM2 65X40X250B 132 40 65 1 100 180 225 65 125 95 320 250 14 12 640 345 405 184 92
73
NRM2 65X50
PUMP PERFORMANCE
Nominal L/1' 400 450 500 550 600 650 700 750 800 900 1000
Power VOLTAGE Amp. Q
CODE MODEL
HP kW
(V) 3 X 400 V m3/h 24 27 30 33 36 39 42 45 48 54 60
Discharge head
7,5 5,5 32,5 32 31,5 31 30,5 30 29,5 29 28 26 23,5
AT07074 NRM2 65X50X160B 380/415 11,3
in meters
AT07075 NRM2 65X50X160A 220/380 30/17,3
10 7,5 37 36,5 36 35,5 35 34,5 34 33,5 32,5 31 29
AT07076 NRM2 65X50X160A 380/415 17,3
AT07079 NRM2 65X50X200B 220/380 39/22,5
13,5 10 51 50,5 50 49 48 47 45,5 44 42 39,5 37
AT07080 NRM2 65X50X200B 380/415 22,5
AT07082 NRM2 65X50X200A 17 12,5 380/415 27 58 57,5 57 56 55 54 53 51,5 50 46,5 42,5
fig.1 fig.2
n° d1 holes ø e1
Flange
UNI PN 16
DN a1 b1 c1 d1 e1
DN
a1
b1
c1
NRM2 65X50X125B 90 50 65 1 100 132 160 50 100 70 240 190 14 12 485 270 292 149 36,5
NRM2 65X50X125A 100 50 65 1 100 132 160 50 100 70 240 190 14 12 525 280 292 159 41
NRM2 65X50X160B 112 50 65 1 100 160 180 50 100 70 265 212 14 12 535 300 340 159 51,5
NRM2 65X50X160A 112 50 65 1 100 160 180 50 100 70 265 212 14 12 535 300 340 159 52
NRM2 65X50X200A 132 50 65 1 100 160 200 50 100 70 265 212 14 12 640 320 360 184 68
NRM2 65X50X200B 132 50 65 1 100 160 200 50 100 70 265 212 14 12 640 320 360 184 75
NRM2 65X50X250D 132 50 65 1 100 180 225 65 125 95 320 250 14 14 640 345 405 184 93
NRM2 65X50X250C 160 50 65 2 100 180 225 55 298 241 320 280 14 22 280 800 20 390 405 230 128
NRM2 65X50X250B 180 50 65 2 100 180 225 55 298 241 320 280 14 22 280 800 20 390 405 230 146
74
NRM2 80X65
PUMP PERFORMANCE
Nominal L/1' 600 650 700 750 800 900 1000 1250 1500 1750 2000 2250
Power VOLTAGE Amp. Q
CODE MODEL
HP kW
(V) 3 X 400 V m3/h 36 39 42 45 48 54 60 75 90 105 120 135
Discharge head
AT07103 NRM2 80x65X160C 220/380 39/22,5
in meters
13,5 10 30,5 30,3 30 29,5 29 26,5 24 20,5 16
AT07104 NRM2 80x65X160C 380/415 22,5
n° d1 holes ø e1
DN
a1
b1
c1
Flange
UNI PN 16
DN a1 b1 c1 d1 e1
65 122 145 185 4 18
80 138 160 200 8 18
NRM2 80X65X125B 112 65 80 1 100 160 180 65 125 95 280 212 14 12 535 300 340 159 51
NRM2 80X65X125A 112 65 80 1 100 160 180 65 125 95 280 212 14 12 535 300 340 159 51,5
NRM2 80X65X160C 132 65 80 1 100 160 200 65 125 95 280 212 14 12 640 325 360 184 70
NRM2 80X65X160B 132 65 80 1 100 160 200 65 125 95 280 212 14 12 640 325 360 184 77
NRM2 80X65X160A 132 65 80 1 100 160 200 65 125 95 280 212 14 12 640 325 360 184 83
NRM2 80X65X200D 132 65 80 1 100 180 225 55 125 95 320 250 14 12 640 345 405 184 87,5
NRM2 80X65X200C 160 65 80 2 100 180 225 55 298 241 320 280 14 22 280 800 20 400 405 230 122
NRM2 80X65X200B 160 65 80 2 100 180 225 55 298 241 320 280 14 22 280 800 20 400 405 230 140
NRM
NRM2 80X65X250D 180 65 80 2 100 180 250 55 298 241 320 280 14 22 293 810 20 365 430 230 144
NRM2 80X65X250C 200 65 80 2 100 200 250 60 345 305 360 318 18 24 325 905 20 400 450 257 172
NRM2 80X65X250B 200 65 80 2 100 200 250 60 345 305 360 318 18 24 325 905 20 400 450 257 190
75
NRM2 100X80
PUMP PERFORMANCE
Nominal L/1' 1000 1250 1500 1750 2000 2250 2500 2750 3000 3500 4000 4500 5000
Power VOLTAGE Amp. Q
CODE MODEL
HP kW
(V) 3 X 400 V m3/h 60 75 90 105 120 135 150 165 180 210 240 270 300
Discharge head
AT07130 NRM2 100X80X160C 17 12,5 380/415 27 28,5 28 27 26 24,5 23 21,5 20 18,5
in meters
AT07132 NRM2 100X80X160B 20 15 380/415 32 34 33,3 32,5 31,8 31 29 27,5 26 24,5
AT07136 NRM2 100X80X200D 25 18,5 380/415 38 42 41 40 38,5 37 35 33 30,5 28
AT07138 NRM2 100X80X200C 30 22 380/415 45 47 46,5 45,5 44,5 43 41 39 37 34
AT07140 NRM2 100X80X200B 40 30 380/415 58 55 54 53 52 51 49 47 45 43 37
AT07142 NRM2 100X80X200A 50 37 380/415 71 57 56,8 56,5 56 55 54 52,5 51 48 42
AT07146 NRM2 100X80X250D 50 37 380/415 71 68 67 66 65 63 61 58 55 47
fig.1 fig.2
n° d1 holes ø e1
Flange
UNI PN 16
DN
DN a1 b1 c1 d1 e1
a1
b1
c1
NRM2 100X80X160C 132 80 100 1 125 180 225 65 125 95 320 250 14 14 665 345 405 184 81,5
NRM2 100X80X160B 132 80 100 1 125 180 225 65 125 95 320 250 14 14 665 345 405 184 88,5
NRM2 100X80X200D 160 80 100 2 125 180 250 55 398 241 320 280 14 22 293 835 20 400 450 230 132
NRM2 100X80X200C 180 80 100 2 125 180 250 55 398 241 320 280 14 22 293 835 20 400 450 230 150
NRM2 100X80X200B 200 80 100 2 125 200 250 60 345 305 360 318 18 24 325 930 20 400 450 257 192
NRM2 100X80X200A 200 80 100 2 125 200 250 60 345 305 360 318 18 24 325 930 20 400 450 257 210
NRM2 100X80X250D 200 80 100 2 125 200 280 60 345 305 360 318 18 24 325 930 20 400 480 257 196
76
NRM2 125X100
PUMP PERFORMANCE
Nominal L/1' 1000 1250 1500 1750 2000 2250 2500 2750 3000 3500 4000 4500 5000
Power VOLTAGE Amp. Q
CODE MODEL
HP kW
(V) 3 X 400 V m3/h 60 75 90 105 120 135 150 165 180 210 240 270 300
Discharge
in meters
AT07154 NRM2 125X100X200D 30 22 380/415 45 39 38 37 36 34,5 33 31,5 28 24
head
AT07156 NRM2 125X100X200C 40 30 380/415 58 47 46,5 46 45 44 42 40 38 33,5 28,4
AT07158 NRM2 125X100X200B 50 37 380/415 71 54 53,5 53 52 51 50 49 46 43 38 34
n° d1 holes ø e1
DN
a1
b1
c1
Flange
UNI PN 16
DN a1 b1 c1 d1 e1
100 158 180 220 8 18
125 188 210 250 8 18
NRM2 125X100X200D 180 100 125 2 125 180 280 55 298 241 320 318 14 22 293 835 20 400 460 230 160
NRM2 125X100X200C 200 100 125 2 125 200 280 60 345 305 360 318 18 24 325 930 20 400 480 257 202
NRM2 125X100X200B 200 100 125 2 125 200 280 60 345 305 360 318 18 24 325 930 20 400 480 257 220
77
NRM4
Performance range
4 POLES
H
(m)
30
25
20
50x32x250
15 80x65x250
65x50 100x80 150x125
x250 x250 x250 250x200
65x40 x250
x250
125x100
80x65x200 x250
150x125
10 x200
50x32x200
65x50
x200 100x80 250x150
8 x200 x200
125x100
65x40 x200
x200 80x65
50x32x160 65x50
6 x160 x160 100x80
x160
65x40
x160 80x65x125
65x50
5 x125
50x32x125
65x40
4 x125
0
40 100 200 400 1000 2000 4000 10000
Q:(L/min)
78
NRM4 50X32
PUMP PERFORMANCE
Nominal L/1' 75 100 125 150 175 200 225 250 275 300
50
Power VOLTAGE Amp. Q
CODE MODEL
HP kW
(V) 3 X 400 V m3/h 3 4,5 6 7,5 9 10,5 12 13,5 15 16,5 18
AT07165 NRM4 50X32X125Y 0,33 0,25 220/380 1,46/0,85 4,4 4 3,5 3 2,2
AT07167 NRM4 50X32X125X 0,33 0,25 6,2 6 5,8 5,2 4,5 3,9 3
Discharge head
220/380 1,46/0,85
in meters
AT07173 NRM4 50X32X160X 0,5 0,37 220/380 2/1,15 9,4 9,2 8,9 8,3 7,7 6,9 5,8 4,7
AT07177 NRM4 50X32X200Y 1 0,75 220/380 3,3/1,9 13 12,8 12,4 11,9 11,3 10,6 9,8 9 8 7 6
AT07179 NRM4 50X32X200X 1,25 0,9 220/380 4,2/2,4 14,5 14,3 13,8 13,3 12,7 11,8 10,9 10 9 8
AT07183 NRM4 50X32X250Y 1,5 1,1 220/380 4,5/3,6 18,5 18,5 17,5 17 16 14,5 13 11,5
AT07185 NRM4 50X32X250X 2 1,5 220/380 6,2/3,6 22 21,5 21 20,5 19,5 18 16,5 15 13
n° d1 holes ø e1
DN
a1
b1
c1
Flange
UNI PN 16
DN a1 b1 c1 d1 e1
32 78 100 140 4 18
50 102 125 165 4 18
PN16 PN16 a h1 h2 b m1 m2 n1 n2 s C L B H E
NRM4 50X32X125Y 71 32 50 80 112 140 50 100 70 190 140 14 12 405 205 252 107 19,5
NRM4 50X32X125X 71 32 50 80 112 140 50 100 70 190 140 14 12 405 205 252 107 19,5
NRM4 50X32X160X 71 32 50 80 132 160 50 100 70 240 190 14 12 405 240 292 107 23
NRM4 50X32X200Y 80 32 50 80 160 180 50 100 70 240 190 14 12 425 255 340 118 31
NRM
NRM4 50X32X200X 80 32 50 80 160 180 50 100 70 240 190 14 12 425 255 340 118 30
NRM4 50X32X250Y 90 32 50 100 180 225 65 125 95 320 250 14 12 485 320 405 149 47
NRM4 50X32X250X 90 32 50 100 180 225 65 125 95 320 250 14 12 485 320 405 149 49
79
NRM4 65X40
PUMP PERFORMANCE
Nominal L/1' 100 125 150 175 200 225 250 275 300 350 400
Power VOLTAGE Amp. Q
CODE MODEL
HP kW
(V) 3 X 400 V m3/h 6 7,5 9 10,5 12 13,5 15 16,5 18 21 24
AT07189 NRM4 65X40X125Y 0,33 0,25 220/380 1,46/0,85 4,6 4,5 4,3 4,1 3,9 3,6 3,3 2,9 2,4
AT07191 0,5 0,37
Discharge head
NRM4 65X40X125X 220/380 2/1,15 6,3 6,2 6,1 6 5,8 5,5 5,2 4,9 4,6 3
in meters
AT07197 NRM4 65X40X160X 0,7 0,5 220/380 2,8/1,6 8,8 8,6 8,3 8 7,7 7,3 6,9 6,4 5,9 4,5
AT07203 NRM4 65X40X200Y 1,5 1,1 220/380 4,5/3,6 12,7 12,5 12,1 11,7 11,2 10,7 10,1 9,5 8,5 7
AT07205 NRM4 65X40X200X 1,5 1,1 220/380 4,5/3,6 14,2 14 13,8 13,4 13 12,5 12 11 10 8,3 6
AT07209 NRM4 65X40X250Y 2 1,5 220/380 6,2/3,6 18,3 18 17,7 17,4 17 16,6 16,2 15,6 15 13,7 12
AT07211 NRM4 65X40X250X 3 2,2 220/380 8,9/5,1 22,5 22,3 22 21,7 21,4 21 20,5 20 19,5 18,5 17
n° d1 holes ø e1
DN
a1
b1
c1
Flange
UNI PN 16
DN a1 b1 c1 d1 e1
40 88 110 150 4 18
65 122 145 185 4 18
PN16 PN16 a h1 h2 b m1 m2 n1 n2 s C L B H E
NRM4 65X40X125Y 71 40 65 80 112 140 50 100 70 210 160 14 12 405 230 252 107 20,5
NRM4 65X40X125X 71 40 65 80 112 140 50 100 70 210 160 14 12 405 230 252 107 21,5
NRM4 65X40X160X 71 40 65 80 132 160 50 100 70 240 190 14 12 405 230 292 107 25
NRM4 65X40X200Y 90 40 65 100 160 180 50 100 70 265 212 14 12 485 242 340 149 36
NRM4 65X40X200X 90 40 65 100 160 180 50 100 70 265 212 14 12 485 242 340 149 36
NRM4 65X40X250Y 90 40 65 100 180 225 65 125 95 320 250 14 12 485 325 405 149 47,5
NRM4 65X40X250X 100 40 65 100 180 225 65 125 95 320 250 14 12 525 325 405 159 54
80
NRM4 65X50
PUMP PERFORMANCE
Nominal L/1' 150 175 200 225 250 275 300 350 400 450 500 550 600 650 700
Power VOLTAGE Amp. Q
CODE MODEL
HP kW
(V) 3 X 400 V m3/h 9 10,5 12 13,5 15 16,5 18 21 24 27 30 33 36 39 42
AT07215 NRM4 65X50X125Y 0,5 0,37 220/380 2/1,15 5,3 5,3 5,2 5,1 5 4,9 4,8 4,5 4,1 3,6 3
AT07217 NRM4 65X50X125X 0,7 0,5 220/380 2,8/1,6 6,4 6,3 6,2 6,1 6 5,9 5,8 5,5 5,2 4,9 4,4
Discharge head
AT07221 NRM4 65X50X160Y 1 0,75 220/380 3,3/1,9 8,2 8 7,9 7,8 7,7 7,4 7 6,6 6 5 4
in meters
AT07223 NRM4 65X50X160X 1,25 0,9 220/380 4,2/2,4 9 8,9 8,8 8,7 8,6 8,4 8,1 7,7 7,2 6,5 5,5
AT07227 NRM4 65X50X200Y 1,5 1,1 220/380 4,5/3,6 12,4 12,2 12 11,8 11,5 10,8 10 9 8 7 5,8
AT07229 NRM4 65X50X200X 2 1,5 220/380 6,2/3,6 14,3 14,2 14,1 14 13,7 13 12,3 11,3 10,2 9,1 7,8 6,4 5
AT07233 NRM4 65X50X250Y 3 2,2 220/380 8,9/5,1 18,5 18,3 18,1 17,8 17,5 17 16,5 15,5 14,5 13,5 12,5 11,5 10
AT07235 NRM4 65X50X250X 4 3 220/380 11/6,4 22,5 22,4 22,3 22,2 22 21,5 20,9 20,2 19,4 18,5 17,5 16,3 15
n° d1 holes ø e1
DN
a1
b1
c1
Flange
UNI PN 16
DN a1 b1 c1 d1 e1
50 102 125 165 4 18
65 122 145 185 4 18
PN16 PN16 a h1 h2 b m1 m2 n1 n2 s C L B H E
NRM4 65X50X125Y 71 50 65 100 132 160 50 100 70 240 190 14 12 425 246 292 107 25
NRM4 65X50X125X 71 50 65 100 132 160 50 100 70 240 190 14 12 425 246 292 107 26
NRM4 65X50X160Y 80 50 65 100 160 180 50 100 70 265 212 14 12 445 269 340 118 32
NRM4 65X50X160X 80 50 65 100 160 180 50 100 70 265 212 14 12 445 269 340 118 33
NRM4 65X50X200Y 90 50 65 100 160 180 50 100 70 265 212 14 12 485 285 360 149 38
NRM
NRM4 65X50X200X 90 50 65 100 160 180 50 100 70 265 212 14 12 485 285 360 149 40
NRM4 65X50X250Y 100 50 65 100 180 225 65 125 95 320 250 14 14 525 333 405 159 57
NRM4 65X50X250X 100 50 65 100 180 225 65 125 95 320 250 14 14 525 333 405 159 63
81
NRM4 80X65
PUMP PERFORMANCE
Nominal L/1' 300 350 400 450 500 550 600 700 800 900 1000 1100 1200 1300 1400
Power VOLTAGE Amp. Q
CODE MODEL
HP kW
(V) 3 X 400 V 3
m /h 18 21 24 27 30 33 36 42 48 54 60 66 72 78 84
AT07241 NRM4 80X65X125X 1 0,75 220/380 3,3/1,9 5,8 5,7 5,6 5,5 5,3 5,1 4,9 4,5 4
AT07245 NRM4 80X65X160Y 1,5 1,1 220/380 4,5/3,6 8,6 8,5 8,4 8,3 8,2 8,1 8 7,5 6,8 6 5
Discharge head
AT07247 NRM4 80X65X160X 2 1,5 220/380 6,2/3,6 10,2 10,1 10 9,9 9,8 9,6 9,4 9 8,5 7,7
in meters
AT07251 NRM4 80X65X200Y 3 2,2 220/380 8,9/5,1 12,5 12,4 12,3 12,2 12,1 11,7 11,1 10,5 9,6 8,5
AT07253 NRM4 80X65X200X 4 3 220/380 11/6,4 15,2 15,1 15 14,6 14,3 13,6 12,8 12 11
AT07257 NRM4 80X65X250Y 220/380 15,2/8,8
5,5 4 19,5 19,3 19,1 18,5 17,5 16,5 15,5 14 12,5 10,5
AT07258 NRM4 80X65X250Y 380/415 8,8
AT07259 NRM4 80X65X250X 220/380 30/17,3
5,5 7,5 23 22,8 22,6 22,2 21,4 20,6 19,7 18,7 17,5 16 14
AT07260 NRM4 80X65X250X 380/415 17,3
n° d1 holes ø e1
DN
a1
b1
c1
Flange
UNI PN 16
DN a1 b1 c1 d1 e1
65 122 145 185 4 18
80 138 160 200 8 18
PN16 PN16 a h1 h2 b m1 m2 n1 n2 s C L B H E
NRM4 80X65X125X 80 65 80 100 160 180 65 125 95 280 212 14 12 445 286 340 118 32
NRM4 80X65X160Y 90 65 80 100 160 200 65 125 95 280 212 14 12 485 288 360 149 37,5
NRM4 80X65X160X 90 65 80 100 160 200 65 125 95 280 212 14 12 485 288 360 149 40
NRM4 80X65X200Y 100 65 80 100 180 225 65 125 95 320 250 14 14 525 328 405 159 51
NRM4 80X65X200X 100 65 80 100 180 225 65 125 95 320 250 14 14 525 328 405 159 57
NRM4 80X65X250Y 112 65 80 100 200 250 80 160 120 360 280 14 14 535 365 450 159 80
NRM4 80X65X250X 132 65 80 100 200 250 80 160 120 360 280 14 14 640 365 450 184 90
82
NRM4 100X80
PUMP PERFORMANCE
Nominal L/1' 600 650 700 800 900 1000 1100 1200 1300 1400 1500 1750 2000 2250
Power VOLTAGE Amp.
CODE MODEL Q
HP kW
(V) 3 X 400 V m /h 3
36 39 42 48 54 60 66 72 78 84 90 105 120 135
AT07263 NRM4 100X80X160Y 2 1,5 220/380 6,2/3,6 7,7 7,6 7,5 7,3 7 6,7 6,4 6,1 5,8 5,4 5
AT07265 NRM4 100X80X160X 3 2,2 220/380 8,9/5,1 9,7 9,6 9,5 9,3 9 8,8 8,5 8,2 7,9 7,5 7,1 6
220/380 11/6,4 12 11,9 11,7 11,5 11,3 11 10,5 10 9,5 9 8,5 7
Discharge head
AT07269 NRM4 100X80X200Y 4 3
in meters
AT07271 NRM4 100X80X200X 220/380 15,2/8,8
5,5 4 14,5 14,4 14,2 14 13,8 13,5 13,1 12,7 12,2 11,6 11 9 6,5
AT07272 NRM4 100X80X200X 380/415 8,8
AT07275 NRM4 100X80X250Y 220/380 19,5/11,3
7,5 5,5 19 18,5 18 17,5 17 16,5 16 14 12
AT07276 NRM4 100X80X250Y 380/415 11,3
AT07277 NRM4 100X80X250X 220/380 30/17,3
10 7,5 22 21,9 21,7 21,5 21,3 21 20 19 17 14,5
AT07278 NRM4 100X80X250X 380/415 17,3
n° d1 holes ø e1
DN
a1
b1
c1
Flange
UNI PN 16
DN a1 b1 c1 d1 e1
80 138 160 200 8 18
100 158 180 220 8 18
PN16 PN16 a h1 h2 b m1 m2 n1 n2 s C L B H E
NRM4 100X80X160Y 90 80 100 125 180 225 65 125 95 320 250 14 14 510 330 405 149 45
NRM4 100X80X160X 100 80 100 125 180 225 65 125 95 320 250 14 14 510 330 405 149 51
NRM4 100X80X200Y 100 80 100 125 180 250 65 125 95 345 280 14 12 560 355 430 159 73
NRM
NRM4 100X80X200X 112 80 100 125 180 250 65 125 95 345 280 14 12 550 355 430 159 66
NRM4 100X80X250Y 132 80 100 125 200 280 80 160 120 400 315 18 14 665 400 480 184 96
NRM4 100X80X250X 132 80 100 125 200 280 80 160 120 400 315 18 14 665 400 480 184 106
83
NRM4 125X100
PUMP PERFORMANCE
Nominal L/1' 900 1000 1100 1200 1300 1400 1500 1750 2000 2250 2500 2750 3000
Power VOLTAGE Amp. Q
CODE MODEL
HP kW
(V) 3 X 400 V m3/h 54 60 66 72 78 84 90 105 120 135 150 165 180
Discharge head
in meters
AT07283 NRM4 125X100X200X 220/380 19,5/11,3
7,5 5,5 14,5 14,4 14,2 14 13,8 13,6 13,4 12,8 12 11 10 8,5
AT07284 NRM4 125X100X200X 380/415 11,3
AT07287 NRM4 125X100X250Y 220/380 30/17,3
10 7,5 19,5 19,3 19,1 18,9 18,7 18,5 17,5 16,5 15,2 14 12
AT07288 NRM4 125X100X250Y 380/415 17,3
AT07290 NRM4 125X100X250X 12,5 9,2 380/415 19 22 21,9 21,8 21,7 21,6 21,5 20,5 19,5 18,5 17 15 13
n° d1 holes ø e1
DN
a1
b1
c1
Flange
UNI PN 16
DN a1 b1 c1 d1 e1
100 158 180 220 8 18
125 188 210 250 8 18
PN16 PN16 a h1 h2 b m1 m2 n1 n2 s C L B H E
NRM4 125X100X200Y 112 100 125 125 200 280 80 160 120 360 280 18 14 560 385 480 1559 78
NRM4 125X100X200X 132 100 125 125 200 280 80 160 120 360 280 18 14 665 385 480 184 90
NRM4 125X100X250Y 132 100 125 140 225 280 80 160 120 400 315 18 14 675 420 505 184 112
NRM4 125X100X250X 132 100 125 140 225 280 80 160 120 400 315 18 14 675 420 505 184 118
84
NRM4 150X125
PUMP PERFORMANCE
Nominal L/1' 1800 2000 2500 3000 3500 4000 4500 5000
Power VOLTAGE Amp. Q
CODE MODEL
HP kW
(V) 3 X 400 V m3/h 108 120 150 180 210 240 270 300
Discharge head
AT07406 NRM4 150X125X200Z 380/415 17,3
in meters
AT07407 NRM4 150X125X200Y 220/380 30/17,3
10 7,5 13 12,8 12,3 11,6 10,5 9,1 7,5
AT07408 NRM4 150X125X200Y 380/415 17,3
AT07410 NRM4 150X125X200X 12,5 9,2 380/415 19 14,3 14,2 13,8 13,2 12,3 11,1 9,6 8
AT07416 NRM4 150X125X250Z 15 11 380/415 22,5 17 16,6 15,7 14,4 12,6
AT07418 NRM4 150X125X250Y 20 15 380/415 27,8 19,8 19 18 16,6 15
AT07420 NRM4 150X125X250X 20 15 380/415 27,8 20,8 19,7 18,6 17 15,2 13,2
n° d1 holes ø e1
DN
a1
b1
c1
Flange
UNI PN 16
DN a1 b1 c1 d1 e1
125 188 210 250 8 18
150 212 240 285 8 22
PN16 PN16 a h1 h2 b m1 m2 n1 n2 s C L B H E
NRM4 150X125X200W 132 125 150 140 250 315 80 160 120 400 315 18 14 700 470 565 255 124
NRM4 150X125X200Z 132 125 150 140 250 315 80 160 120 400 315 18 14 700 470 565 255 134
NRM4 150X125X200Y 132 125 150 140 250 315 80 160 120 400 315 18 14 700 470 565 255 134
NRM4 150X125X200X 132 125 150 140 250 315 80 160 120 400 315 18 14 700 470 565 255 140
NRM
NRM4 150X125X250Z 132 125 150 140 250 355 80 160 120 400 315 18 14 700 470 605 255 162
NRM4 150X125X250Y 160 125 150 140 250 355 80 160 120 400 315 18 14 855 470 605 255 190
NRM4 150X125X250X 160 125 150 140 250 355 80 160 120 400 315 18 14 855 470 605 255 190
85
NRM4 200X150
PUMP PERFORMANCE
Nominal L/1' 2500 4000 5000 5500 7000
3000 3500 4500 6000
Power VOLTAGE Amp. Q
CODE MODEL
HP kW
(V) 3 X 400 V 3
m /h 150 180 210 240 270 300 330 360 450
Discharge head
10 7,5 10,4 9,7 8,9 7,9 6,7 5,5
AT07424 NRM4 200X150X200W 380/415 17,3
in meters
AT07426 NRM4 200X150X200Z 12,5 9,2 380/415 19 11,5 10,9 10,2 9,3 8,3 7 5,8
AT07428 NRM4 200X150X200Y 15 11 380/415 22,5 13,3 12,6 12 11,1 10,1 9 7,6
AT07430 NRM4 200X150X200X 20 15 380/415 27,8 14,5 14 13,2 12,5 11,6 10,6 9,4 8
n° d1 holes ø e1
DN
a1
b1
c1
Flange
UNI PN 16
DN a1 b1 c1 d1 e1
150 212 240 285 8 22
200 268 295 340 8 22
PN16 PN16 a h1 h2 b m1 m2 n1 n2 s C L B H E
NRM4 200X150X200W 132 150 200 160 280 400 100 200 155 550 450 24 22 855 550 680 295 167
NRM4 200X150X200Z 132 150 200 160 280 400 100 200 155 550 450 24 22 855 550 680 295 173
NRM4 200X150X200Y 132 150 200 160 280 400 100 200 155 550 450 24 22 855 550 680 295 175
NRM4 200X150X200X 160 150 200 160 280 400 100 200 155 550 450 24 22 875 550 680 295 203
86
NRM4 250X200
PUMP PERFORMANCE
Nominal L/1' 4500 5000 5500 6000 6500 7000 8000 9000 10000
Power VOLTAGE Amp. Q
CODE MODEL
HP kW
(V) 3 X 400 V 3
m /h 270 300 330 360 390 450 480 540 600
AT07434 NRM4 250X200X250W 25 18,5 380/415 32 13,5 13 12,4 11,8 11,2 10,5 9
Discharge
in meters
AT07436 NRM4 250X200X250Z 25 18,5 380/415 32 14,6 14 13,5 13 12,4 11,7 10,2
head
AT07438 NRM4 250X200X250Y 30 22 380/415 39 17 16,5 16 15,4 14,7 14 12,4 10,5
AT07440 NRM4 250X200X250X 30 22 380/415 39 18,6 18 17,6 17 16,4 15,8 14,3 12,5 10,6
n° d1 holes ø e1
DN
a1
b1
c1
Flange
UNI PN 16
DN a1 b1 c1 d1 e1
200 268 295 340 8 22
250 320 350 395 8 25
PN16 PN16 a h1 h2 b m1 m2 n1 n2 s C L B H E
NRM4 250X200X250W 180 200 250 200 315 450 100 200 155 550 450 24 22 1000 630 765 350 278
NRM
NRM4 250X200X250Z 180 200 250 200 315 450 100 200 155 550 450 24 22 1000 630 765 350 278
NRM4 250X200X250Y 180 200 250 200 315 450 100 200 155 550 450 24 22 1000 630 765 350 300
NRM4 250X200X250X 180 200 250 200 315 450 100 200 155 550 450 24 22 1000 630 765 350 300
87
NRB
CENTRIFUGAL PUMPS WITH BASE-PLATE AND COUPLING.
NORMALIZED DIMENSIONS DIN 24255 - UNI 7467 - EN733
89
NRB
HORIZONTAL CENTRIFUGAL PUMPS WITH BASE-PLATE AND
COUPLING (2 AND 4 POLES)
Applications
– Aqueducts
– Irrigation
– Water distribution
– Industrial applications
DESIGN FEATURES
Component Material
1 Pump body Cast iron EN GJL 200 (ex G20)
2 Impeller Cast iron EN GJL 200 (ex G20)
Bronze (on request)
3 Casing cover Cast iron EN GJL 200 (ex G20)
4 Bearing housing Cast iron EN GJL 200 (ex G20)
5 Shaft Stainless steel AISI420
6 Mechanical seal Ceramic/graphite/EPDM
Silicon carbide/silicon carbide/EPDM
90
NRB2
Performance range
H 2 POLES
(m)
125
100
80
32X250 40X250 50X250 65X250 80X250
100X250
60
30
50X160 65X160 80X160
32X160 40X160
20 50X120
40X120 65X120
32X120
10
5
6 10 20 50 100 200 400
Q:(m3/h)
NRB 2
91
NRB2 32
PUMP PERFORMANCE
Nominal L/1' 100 150 200 250 300 350 400 450
Power VOLTAGE Amp. Q
CODE MODEL
HP kW
(V) 3 X 400 V m3/h 6 9 12 15 18 21 24 27
Discharge head
PA021040 NRB2 32X160 B 4 3 230/400 11,1/6,4 34,5 33,5 31,5 29 26
in meters
PA020020 NRB2 32X160 A 4 3 230/400 11,1/6,4 38 36,5 35 32,5 30 26,5
PA020720 NRB2 32X200 C 5,5 4 230/400 14,8/8,5 47,5 46,5 44,5 42,5 39 35
PA020900 NRB2 32X200 B 7,5 5,5 400 11,3 56 55 53,5 51,5 49,5 46 42 37
PA020750 NRB2 32X200 A 10 7,5 400 15 61 60,5 59 57,5 55 52,5 49 45
PA020010 NRB2 32X250 C 12,5 9,2 400 18 75 74,5 74 72 68 62 56
PA020400 NRB2 32X250 B 15 11 400 20,5 85,5 85 84,5 83 80 76 70 63
PA020330 NRB2 32X250 A 20 15 400 27 92 91,5 91 90 88 84 79 73
NRB2 32X120 A 90 S2 302 16 32 50 80 360 140 240 170 850 800 25 197 85 100 65
NRB2 32X120 B 80 B2 280 16 32 50 80 360 140 240 170 850 800 25 197 85 100 63
NRB2 32X120 C 80 A2 280 16 32 50 80 360 140 240 170 850 800 25 197 85 100 61
NRB2 32X160 A 100 L2 369 22 32 50 80 360 160 240 170 850 800 25 217 85 100 80
NRB2 32X160 B 100 L2 369 22 32 50 80 360 160 240 170 850 800 25 217 85 100 80
NRB2 32X160 C 90 L2 327 16 32 50 80 360 160 240 170 850 800 25 217 85 100 74
NRB2 32X200 A 112 MC2 386 22 32 50 80 360 180 240 170 850 800 25 245 85 100 98
NRB2 32X200 B 112 MB2 386 22 32 50 80 360 180 240 170 850 800 25 245 85 100 95
NRB2 32X200 C 112 M2 386 22 32 50 80 360 180 240 170 850 800 25 245 85 100 95
NRB2 32X250 A 132 MD2 498 24 32 50 100 360 225 350 280 950 900 25 280 100 100 164
NRB2 32X250 B 132 MC2 498 24 32 50 100 360 225 350 280 950 900 25 280 100 100 156
NRB2 32X250 C 132 MB2 498 24 32 50 100 360 225 350 280 950 900 25 280 100 100 151
92
NRB2 40
PUMP PERFORMANCE
Nominal L/1' 200 250 300 350 400 450 500 550 600 650 700 750
Power VOLTAGE Amp. Q
CODE MODEL
HP kW
(V) 3 X 400 V m /h 3
12 15 18 21 24 27 30 33 36 39 42 45
Discharge head
PA021090 NRB2 40X160 B 5,5 4 230/400 14,8/8,5 34 33 32 31 30 28,5 26,5 24,5 21,5
in meters
PA020210 NRB2 40X160 A 5,5 4 230/400 14,8/8,5 37 36,5 35,5 34,5 33,5 32,5 31 29 26,5
PA020350 NRB2 40X200 C 7,5 5,5 400 11,3 43,5 43 42 40 38 36 33 29 24
PA020150 NRB2 40X200 B 10 7,5 400 15,0 52 51 50 49 47 45 43 40 37 33 28
NRB2 40X120 A 100 L2 369 22 40 65 80 360 140 240 170 850 800 25 197 85 100 75
NRB2 40X120 B 90 L2 327 16 40 65 80 360 140 240 170 850 800 25 197 85 100 69
NRB2 40X120 C 90 S2 302 16 40 65 80 360 140 240 170 850 800 25 197 85 100 67
NRB2 40X160 A 112 M2 386 22 40 65 80 360 160 240 170 850 800 25 217 85 100 91
NRB2 40X160 B 112 M2 386 22 40 65 80 360 160 240 170 850 800 25 217 85 100 91
NRB2 40X160 C 100 L2 369 22 40 65 80 360 160 240 170 850 800 25 217 85 100 81
NRB2 40X200 A 132 MB2 498 24 40 65 100 360 180 280 210 950 900 25 255 95 100 128
NRB 2
NRB2 40X200 B 112 MC2 386 22 40 65 100 360 180 280 210 950 900 25 255 95 100 112
NRB2 40X200 C 112 MB2 386 22 40 65 100 360 180 280 210 950 900 25 255 95 100 109
NRB2 40X250 A 160 L2 645 24 40 65 100 360 225 350 280 1120 1070 25 280 100 100 282
NRB2 40X250 B 132 MD2 498 24 40 65 100 360 225 350 280 950 900 25 280 100 100 173
NRB2 40X250 C 132 MC2 498 24 40 65 100 360 225 350 280 950 900 25 280 100 100 165
93
NRB2 50
PUMP PERFORMANCE
Nominal L/1' 400 450 500 600 700 800 900 1000 1100 1200 1300
Power VOLTAGE Amp. Q
CODE MODEL
HP kW
(V) 3 X 400 V 3
m /h 24 27 30 36 42 48 54 60 66 72 78
Discharge head
PA020070 NRB2 50X160 A 10 7,5 400 15 37 36,5 36 35 34 32,5 31 29 26
in meters
PA020190 NRB2 50X200 C 10 7,5 400 15 47 46,5 45 43 40 36 31,5
PA020050 NRB2 50X200 B 12,5 9,2 400 18,0 52,5 52 51,5 49,5 46,5 43,5 39,5 35
PA020090 NRB2 50X200 A 15 11 400 20,5 57,5 57 56,5 55 53 50 46,5 43
PA020880 NRB2 50X250 D 20 15 400 27,0 70 69,5 67,5 65 61,5 57,5 51
PA020130 NRB2 50X250 C 25 18,5 400 32,0 77 76,5 75 72,5 69,5 66 61,5 55,5
PA020180 NRB2 50X250 B 30 22 400 39,0 88 87,5 86 84 82 78,5 74,5 69
PA020200 NRB2 50X250 A 40 30 400 52,0 94,5 94 93 91,5 89,5 86,5 83,5 80 75,5 70
NRB2 50X120 A 112 M2 386 22 50 65 100 360 160 240 170 850 800 25 217 85 100 90
NRB2 50X120 B 100 L2 369 22 50 65 100 360 160 240 170 850 800 25 217 85 100 80
NRB2 50X120 C 90 L2 327 16 50 65 100 360 160 240 170 850 800 25 217 85 100 74
NRB2 50X160 A 112 MC2 386 22 50 65 100 360 180 280 210 950 900 25 255 95 100 108
NRB2 50X160 B 112 MB2 386 22 50 65 100 360 180 280 210 950 900 25 255 95 100 105
NRB2 50X160 C 112 M2 386 22 50 65 100 360 180 280 210 950 900 25 255 95 100 105
NRB2 50X200 A 132 MC2 498 24 50 65 100 360 200 280 210 950 900 25 255 95 100 134
NRB2 50X200 B 132 MB2 498 24 50 65 100 360 200 280 210 950 900 25 255 95 100 129
NRB2 50X200 C 112 MC2 386 22 50 65 100 360 200 280 210 950 900 25 255 95 100 113
NRB2 50X250 A 200 LA2 775 28 50 65 100 360 225 400 330 1320 1270 25 310 110 100 394
NRB2 50X250 B 180 M2 670 28 50 65 100 360 225 400 330 1120 1070 25 290 110 100 316
NRB2 50X250 C 160 L2 645 24 50 65 100 360 225 350 280 1120 1070 25 280 100 100 283
NRB2 50X250 D 132 MD2 498 24 50 65 100 360 225 350 280 950 900 25 280 100 100 185
94
NRB2 65
PUMP PERFORMANCE
Nominal L/1' 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1800 2000 2250
Power VOLTAGE Amp. Q
CODE MODEL
HP kW
(V) 3 X 400 V m3/h 36 42 48 54 60 66 72 78 84 90 96 108 120 135
PA021150 NRB2 65X120 C 5,5 4 230/400 14,8/8,5 18 17,5 17,2 16,6 15,8 15 14 12,6
PA021160 NRB2 65X120 B 7,5 5,5 400 11,3 21,4 21,1 20,5 20,3 19,8 19,2 18,4 17,5 16,4
PA021170 NRB2 65X120 A 10 7,5 400 15 23,8 23,6 23,4 23 22,6 22 21,5 20,7 20 19 17,5
PA021180 NRB2 65X160 C 12,5 9,2 400 18 30,8 30 29,5 28,5 27,5 26,5 25,5 24 25,5 21
Discharge head
PA020660 NRB2 65X160 B 15 11 400 20,5 33,8 33 32,5 32 31,5 30,5 29,5 28,5 27 25,5 22,5
in meters
PA020990 NRB2 65X160 A 20 15 400 27,0 40,8 40 39,5 39 38,5 38 37,5 36,5 35,5 34,5 32 29
PA020140 NRB2 65X200 C 25 18,5 400 32,0 51 50,6 50,4 50,2 50,1 49,7 48,6 47,5 46 43 39
PA020930 NRB2 65X200 B 30 22 400 39,0 57,5 57 56,6 56,5 56,3 56 55,5 54,5 53,5 50,5 47,5 42,5
PA020031 NRB2 65X200 A 30 30 400 52,0 62 61,7 61,5 61,3 61,1 61 60,5 60 59 57,5 55 50
PA020100 NRB2 65X250 C 40 30 400 52,0 72 71,5 71 70 68,5 67 65 63,3 61,2 57
PA020980 NRB2 65X250 B 50 37 400 65,0 82,5 82 81,5 80,5 79,5 78,5 77 75,5 70 70 65,5 59,5
PA020310 NRB2 65X250 A 60 45 400 78,0 92,5 92 91,5 91 90 89 88 87 86 82 78 72,5
NRB2 65X120 A 112 MC2 386 22 65 80 100 360 180 280 210 950 900 25 255 95 100 106
NRB2 65X120 B 112 MB2 386 22 65 80 100 360 180 280 210 950 900 25 255 95 100 106
NRB2 65X120 C 112 M2 386 22 65 80 100 360 180 280 210 950 900 25 255 95 100 106
NRB2 65X160 A 132 MD2 498 24 65 80 100 360 200 280 210 950 900 25 255 95 100 142
NRB2 65X160 B 132 MC2 498 24 65 80 100 360 200 280 210 950 900 25 255 95 100 134
NRB2 65X160 C 132 MB2 498 24 65 80 100 360 200 280 210 950 900 25 255 95 100 129
NRB2 65X200 A 200 LA2 775 28 65 80 100 360 225 400 330 1320 1270 25 310 110 100 388
NRB2 65X200 B 180 M2
NRB 2
670 28 65 80 100 360 225 400 330 1120 1070 25 290 110 100 310
NRB2 65X200 C 160 L2 645 24 65 80 100 360 225 350 280 1120 1070 25 280 100 100 277
NRB2 65X250 A 225 M2 815 33 65 80 100 470 250 580 540 1400 1300 50 355 20 100 543
NRB2 65X250 B 200 LB2 775 28 65 80 100 470 250 400 330 1320 1270 25 310 110 125 419
NRB2 65X250 C 200 LA2 775 28 65 80 100 470 250 400 330 1320 1270 25 310 110 125 399
95
NRB2 80
PUMP PERFORMANCE
Nominal L/1' 1200 1300 1400 1500 1600 1800 2000 2250 2500 2750 3000 3250 3500 4000
Power VOLTAGE Amp. Q
CODE MODEL
HP kW
(V) 3 X 400 V 3
m /h 72 78 84 90 96 108 120 135 150 165 180 195 210 240
PA021190 NRB2 80X160 C 15 11 400 20,5 28,5 28 27,5 27 26,5 26 24,8 22,5 20
PA021200 NRB2 80X160 B 20 15 400 27,0 33,6 33,5 33,4 33 32,5 32 31 29,5 28 24,5 23
PA020925 NRB2 80X160 A 25 18,5 400 32,0 38 37,8 37,6 37,2 36,8 36,5 35,5 34,5 33 31,5 29 27
Discharge head
PA020935 NRB2 80X200 C 30 22 400 39,0 44,6 44,5 44 43,5 43 42 40,5 38,5 36,5 33,5 31
in meters
PA020945 NRB2 80X200 B 40 30 400 52,0 53 52,5 52 51,5 51 50,5 49,5 48 46 44 41,5 38,5
PA020955 NRB2 80X200 A 50 37 400 65,0 58,5 58 57,5 57 56,5 56 55,5 54 52,5 50,5 48,5 46 43,5
PA020860 NRB2 80X250 D 50 37 400 65,0 68 67,5 66,5 65 62,5 60 56 51
PA020965 NRB2 80X250 C 60 45 400 78,0 74,6 74,5 73,5 72,5 70,5 68 65 61,5 57,5 53
PA020932 NRB2 80X250 B 75 55 400 95,0 84 83,5 83 82 81 78,5 76 73,5 70 66
PA020934 NRB2 80X250 A 100 75 400 127,0 90,5 90 89,5 89 87,5 86 84 81,5 78,5 75 66
NRB2 80X160 A 160 L2 645 24 80 100 125 360 225 350 280 1120 1070 25 280 100 100 278
NRB2 80X160 B 132 MD2 498 24 80 100 125 360 225 350 280 950 900 25 280 100 100 180
NRB2 80X160 C 132 MC2 498 24 80 100 125 360 225 350 280 950 900 25 280 100 100 172
NRB2 80X200 A 200 LB2 775 28 80 100 125 470 250 400 330 1320 1270 25 310 110 100 424
NRB2 80X200 B 200 LA2 775 28 80 100 125 470 250 400 330 1320 1270 25 310 110 100 404
NRB2 80X200 C 180 M2 670 28 80 100 125 470 250 400 330 1320 1270 25 290 110 100 341
NRB2 80X250 A 280 S2 1000 33 80 100 125 470 280 660 620 1600 1500 50 415 20 100 833
NRB2 80X250 B 250 M2 930 33 80 100 125 470 280 660 620 1600 1500 50 390 20 100 683
NRB2 80X250 C 225 M2 815 33 80 100 125 470 280 580 540 1400 1300 50 355 20 100 553
NRB2 80X250 D 200 LB2 775 28 80 100 125 470 280 330 330 1320 1320 25 310 110 125 429
96
NRB2 100
PUMP PERFORMANCE
Nominal L/1' 2000 2250 2500 2750 3000 3250 3500 4000 4500 5000 5500
Power VOLTAGE Amp.
CODE MODEL Q
HP kW
(V) 3 X 400 V m3/h 120 135 150 165 180 195 210 240 270 300 330
PA021210 NRB2 100X200 D 30 22 400 39,0 37,5 36,5 35 33,5 31,5 29 27 20,5
PA021220 NRB2 100X200 C 40 30 400 52,0 45 44,5 43,5 42,5 41 39,5 37,5 33 27
Discharge head
PA021230 NRB2 100X200 B 50 37 400 65,0 50,5 50 49,5 48,5 47,5 46,5 45 41,5 36,5 31
in meters
PA020770 NRB2 100X200 A 60 45 400 78,0 55,5 55 54,5 54 53 52 51 48 43,5 38
PA021240 NRB2 100X250 D 60 45 400 78,0 66,5 66 65 63,5 61,5 58,5 56 49,5
PA020740 NRB2 100X250 C 75 55 400 95,0 73 72,5 72 71 69,5 68 66 61 53,5
PA020950 NRB2 100X250 B 100 75 400 127,0 83 82,8 82,5 82 81 79,5 78 74 70 63 55
PA020960 NRB2 100X250 A 125 90 400 152,0 89,5 89,3 89 88,2 87,5 86,5 85,5 82,5 78 73 65
NRB2 100X250 A 280 M2 1050 33 100 125 140 470 280 660 620 1600 1500 50 415 20 100 883
NRB2 100X250 B 280 S2 1000 33 100 125 140 470 280 660 620 1600 1500 50 415 20 100 837
NRB2 100X250 C 250 M2 930 33 100 125 140 470 280 660 620 1600 1500 50 390 20 100 695
NRB2 100X250 D 225 M2 815 33 100 125 140 470 280 580 540 1400 1300 50 355 20 100 557
97
NRB4
Performance range
4 POLES
H 30
(m)
25
20
32x250 80x250
15 40x250 65x250
50x250
100x250
10 32x200 65x200
40x200 80x200
50x200
100x200
8
32x160 80x160
40x160 65x160
6 50x160
32x120 65x120
4 40x120
50x120
3 5 10 20 50 100 200
Q:(m3/h)
98
NRB4 32
PUMP PERFORMANCE
Nominal L/1' 50 75 100 125 150 175 200 225 250
Power VOLTAGE Amp.
CODE MODEL Q
HP kW
(V) 3 X 400 V m /h 3
3 4,5 6 7,5 9 11 12 14 15
PA021950 NRB4 32X120 C 0,33 0,25 230/400 1,46 - 0,85 4,5 4,3 3,8 3 2,1
PA021960 NRB4 32X120 B 0,33 0,25 230/400 1,46 - 0,85 5,4 5,2 4,8 4,2 3,4 2,5
PA021970 NRB4 32X120 A 0,33 0,25 230/400 1,46 - 0,85 6,2 6 5,8 5,3 4,6 3,8 2,9
PA021980 NRB4 32X160 C 0,33 0,25 230/400 1,46 - 0,85 7,8 7,6 7,2 6,5 5,6 4,6
Discharge head
PA021990 NRB4 32X160 B 0,5 0,37 230/400 2 - 1,15 8,6 7,9 8 7,5 6,7 5,7 4,6
in meters
PA022000 NRB4 32X160 A 0,5 0,37 230/400 2 - 1,15 9,4 9,2 8,9 8,4 7,7 6,8 5,8
PA022010 NRB4 32X200 C 0,75 0,55 230/400 2 - 1,15 11,2 10,8 10,2 9,5 8,6 7,5 6,5
PA022020 NRB4 32X200 B 1 0,75 230/400 3,3 - 1,9 13,2 13 12,5 11,8 11,1 10,3 9,2 8,2
PA021250 NRB4 32X200 A 1,5 1,1 230/400 4,7 - 2,7 14,5 14,2 13,8 13,3 12,6 11,8 10,9 10
PA021260 NRB4 32X250 C 1,5 1,1 230/400 4,7 - 2,7 18 17,5 16,8 15,7 14,2 12,7 10,8
PA021270 NRB4 32X250 B 2 1,5 230/400 6,1 - 3,5 20,4 20 19,5 18,6 17,4 16 14,4 12,5
PA021280 NRB4 32X250 A 2 1,5 230/400 6,1 - 3,5 22 21,6 21,2 20,4 19,4 18 16,5 14,8
NRB4 32X120 A 71 A4 244 16 32 50 80 360 140 240 170 850 800 25 197 85 100 59
NRB4 32X120 B 71 A4 244 16 32 50 80 360 140 240 170 850 800 25 197 85 100 59
NRB4 32X120 C 71 A4 244 16 32 50 80 360 140 240 170 850 800 25 197 85 100 59
NRB4 32X160 A 71 B4 244 16 32 50 80 360 160 240 170 850 800 25 217 85 100 66
NRB4 32X160 B 71 B4 244 16 32 50 80 360 160 240 170 850 800 25 217 85 100 66
NRB4 32X160 C 71 A4 244 16 32 50 80 360 160 240 170 850 800 25 217 85 100 66
NRB4 32X200 A 90 S4 302 16 32 50 80 360 180 240 170 850 800 25 245 85 100 77
NRB4 32X200 B
NRB 4
NRB4 32X250 C 90 S4 302 16 32 50 100 360 225 350 280 950 900 25 280 100 100 114
99
NRB4 40
PUMP PERFORMANCE
Nominal L/1' 100 125 150 175 200 225 250 275 300 350 400 450
Power VOLTAGE Amp. Q
CODE MODEL
HP kW
(V) 3 X 400 V m3/h 6 7,5 9 10,5 12 13,5 15 16,5 18 21 24 27
PA022030 NRB4 40X120 C 0,33 0,25 230/400 1,46 - 0,85 4,6 4,5 4,3 4 3,7 3,3 2,5
PA022040 NRB4 40X120 B 0,5 0,37 230/400 2 - 1,15 5,4 5,3 5,2 5 4,8 4,5 4,1 3,5
PA022050 NRB4 40X120 A 0,5 0,37 230/400 2 - 1,15 6,3 6,2 6,1 6 5,8 5,5 5,2 4,9 4,4
PA022060 NRB4 40X160 C 0,5 0,37 230/400 2 - 1,15 7,3 7 6,7 6,4 6 5,5 4,9 4,3
Discharge head
PA022070 NRB4 40X160 B 0,75 0,55 230/400 2 - 1,15 8 7,8 7,5 7,2 6,8 6,4 5,9 5,3 4,7
in meters
PA022080 NRB4 40X160 A 0,75 0,55 230/400 2 - 1,15 8,8 8,6 8,4 8,1 7,7 7,3 6,8 6,3 5,8
PA022090 NRB4 40X200 C 1 0,75 230/400 3,3 - 1,9 11 10,5 10 9,4 8,5 7,6 6,6 5,4
PA021290 NRB4 40X200 B 1,5 1,1 230/400 4,7 - 2,7 12,8 12,5 12,1 11,6 11 10,2 9,3 8,4 6,2
PA021300 NRB4 40X200 A 1,5 1,1 230/400 4,7 - 2,7 14 13,8 13,5 13 12,4 11,8 11 10,2 8,3
PA021310 NRB4 40X250 C 2 1,5 230/400 6,1 - 3,5 17,2 17 16,6 16 15,3 14,5 14 13 10,6
PA021320 NRB4 40X250 B 3 2,2 230/400 8,5 - 4,9 19,7 19,5 19,2 18,6 18 17,5 16,8 16 14 11,5
PA021330 NRB4 40X250 A 3 2,2 230/400 8,5 - 4,9 22,3 22 21,7 21,4 21 20,3 19,6 19 17,5 15,5 13
NRB4 40X120 A 71 B4 244 16 40 65 80 360 140 240 170 850 800 25 197 85 100 62
NRB4 40X120 B 71 B4 244 16 40 65 80 360 140 240 170 850 800 25 197 85 100 62
NRB4 40X120 C 71 A4 244 16 40 65 80 360 140 240 170 850 800 25 197 85 100 61
NRB4 40X160 A 80 A4 280 16 40 65 80 360 160 240 170 850 800 25 217 85 100 69
NRB4 40X160 B 80 A4 280 16 40 65 80 360 160 240 170 850 800 25 217 85 100 69
NRB4 40X160 C 71 B4 244 16 40 65 80 360 160 240 170 850 800 25 217 85 100 67
NRB4 40X200 A 90 S4 302 16 40 65 100 360 180 280 210 950 900 25 255 95 100 91
NRB4 40X200 B 90 S4 302 16 40 65 100 360 180 280 210 950 900 25 255 95 100 91
NRB4 40X200 C 80 B4 280 16 40 65 100 360 180 280 210 950 900 25 255 95 100 89
NRB4 40X250 A 100 LA4 369 22 40 65 100 360 225 350 280 950 900 25 280 100 100 131
NRB4 40X250 B 100 LA4 369 22 40 65 100 360 225 350 280 950 900 25 280 100 100 131
NRB4 40X250 C 90 L4 327 16 40 65 100 360 225 350 280 950 900 25 280 100 100 124
100
NRB4 50
PUMP PERFORMANCE
Nominal L/1' 150 200 250 300 350 400 450 500 550 600 700
Power VOLTAGE Amp. Q
CODE MODEL
HP kW
(V) 3 X 400 V m3/h 9 12 15 18 21 24 27 30 33 36 42
PA022100 NRB4 50X120 C 0,33 0,25 230/400 1,46 - 0,85 4,4 4,2 4 3,6 3,2 2,6
PA022110 NRB4 50X120 B 0,5 0,37 230/400 2 - 1,15 5,3 5,1 4,9 4,7 4,4 4 3,5
PA022120 NRB4 50X120 A 0,75 0,55 230/400 2 - 1,15 6,3 6,1 5,9 5,7 5,5 5,2 4,8 4,4
PA022130 NRB4 50X160 C 0,75 0,55 230/400 2 - 1,15 6,8 6,6 6,3 5,9 5,3 4,4
Discharge head
PA022140 NRB4 50X160 B 1,0 0,75 230/400 3,3 - 1,9 8 7,8 7,6 7,4 7 6,4 5,6
in meters
PA021340 NRB4 50X160 A 1,5 1,1 230/400 4,7 - 2,7 9 8,8 8,6 8,4 8,2 7,7 7,1 6,4
PA021350 NRB4 50X200 C 1,5 1,1 230/400 4,7 - 2,7 11,6 11,2 10,5 9,6 8,6 7,4 6,2
PA021360 NRB4 50X200 B 1,5 1,1 230/400 4,7 - 2,7 13 12,6 12,2 11,3 10,4 9,4 8,2 7
PA021370 NRB4 50X200 A 2,0 1,5 230/400 6,1 - 3,5 14,3 14,1 13,7 13,1 12,3 11,4 10,2 9 7,8
PA021380 NRB4 50X250 D 3,0 2,2 230/400 8,5 - 4,9 16,8 16,4 15,8 15,1 14,2 13,2 11,9 10,5
PA021390 NRB4 50X250 C 3,0 2,2 230/400 8,5 - 4,9 18,4 18 17,6 17 16,2 15,2 14,2 12,8 11,5
PA021400 NRB4 50X250 B 4,0 3,0 230/400 11,1 - 6,4 21 20,6 20,2 19,7 19,1 18,3 17,4 16,4 15,2
PA021410 NRB4 50X250 A 4,0 3,0 230/400 11,1 - 6,4 22,5 22,3 22 21,5 20,9 20,2 19,4 18,5 17,4 14,7
NRB4 50X120 A 80 A4 280 16 50 65 100 360 160 240 170 850 800 25 217 85 100 68
NRB4 50X120 B 71 B4 244 16 50 65 100 360 160 240 170 850 800 25 217 85 100 66
NRB4 50X120 C 71 A4 244 16 50 65 100 360 160 240 170 850 800 25 217 85 100 65
NRB4 50X160 A 90 S4 302 16 50 65 100 360 180 280 210 950 900 25 255 95 100 87
NRB4 50X160 B 80 B4 280 16 50 65 100 360 180 280 210 950 900 25 255 95 100 85
NRB4 50X160 C 80 A4 280 16 50 65 100 360 180 280 210 950 900 25 255 95 100 83
NRB4 50X200 A 90 L4 327 16 50 65 100 360 200 280 210 950 900 25 255 95 100 93
NRB4 50X200 B 90 S4 302 16 50 65 100 360 200 280 210 950 900 25 255 95 100 92
NRB4 50X200 C 90 S4 302 16 50 65 100 360 200 280 210 950 900 25 255 95 100 92
NRB 4
NRB4 50X250 A 100 LB4 369 22 50 65 100 360 225 350 280 950 900 25 280 100 100 135
NRB4 50X250 B 100 LB4 369 22 50 65 100 360 225 350 280 950 900 25 280 100 100 135
NRB4 50X250 C 100 LA4 369 22 50 65 100 360 225 350 280 950 900 25 280 100 100 132
NRB4 50X250 D 100 LA4 369 22 50 65 100 360 225 350 280 950 900 25 280 100 100 132
101
NRB4 65
PUMP PERFORMANCE
Nominal L/1' 250 300 350 400 450 500 550 600 700 800 900 1000 1100 1200 1400
Power VOLTAGE Amp. Q
CODE MODEL
HP kW
(V) 3 X 400 V m3/h 15 18 21 24 27 30 33 36 42 48 54 60 66 72 84
PA022150 NRB4 65X120 C 0,75 0,55 230/400 2 - 1,15 4,2 4 3,9 3,8 3,7 3,5 3,3 3
PA022160 NRB4 65X120 B 0,75 0,55 230/400 2 - 1,15 5 4,8 4,7 4,6 4,5 4,4 4,3 4,2 3,7
PA022170 NRB4 65X120 A 1,0 0,75 230/400 3,3 - 1,9 5,6 5,5 5,4 5,3 5,2 5,1 4,9 4,5 4
PA021420 NRB4 65X160 C 1,5 1,1 230/400 4,7 - 2,7 7,7 7,6 7,5 7,3 7,1 6,8 6,5 5,7 4,7
Discharge head
PA021430 NRB4 65X160 B 1,5 1,1 230/400 4,7 - 2,7 8,5 8,4 8,3 8,2 8 7,8 7,6 6,9 5,9 4,9
in meters
PA021440 NRB4 65X160 A 2,0 1,5 230/400 6,1 - 3,5 10,2 10,1 10 9,9 9,8 9,6 9,4 9 8,4 7,5 6,5
PA021450 NRB4 65X200 C 3,0 2,2 230/400 8,5 - 4,9 12,3 12,2 12,1 12 11,9 11,5 10,8 10 9
PA021460 NRB4 65X200 B 4,0 3,0 230/400 11,1 - 6,4 13,7 13,6 13,5 13,4 13,3 13,1 12,6 11,9 11 10
PA021470 NRB4 65X200 A 4,0 3,0 230/400 11,1 - 6,4 15 14,9 14,8 14,7 14,6 14,4 14,1 13,5 12,8 12 11
PA021480 NRB4 65X250 C 4,0 3,0 230/400 11,1 - 6,4 17,2 17 16,6 15,7 14,6 13,2 1,6
PA021490 NRB4 65X250 B 5,5 4,0 230/400 14,8 - 8,5 20 19,7 19,4 18,8 18 16,8 15,6 14,3 12,5
PA021500 NRB4 65X250 A 7,5 5,5 400 11,3 23 22,8 22,6 22,1 21,5 20,7 19,7 18,6 17,4 14
NRB4 65X120 A 80 B4 280 16 65 80 100 360 180 280 210 950 900 25 255 95 100 86
NRB4 65X120 B 80 A4 280 16 65 80 100 360 180 280 210 950 900 25 255 95 100 84
NRB4 65X120 C 80 A4 280 16 65 80 100 360 180 280 210 950 900 25 255 95 100 84
NRB4 65X160 A 90 L4 327 16 65 80 100 360 200 280 210 950 900 25 255 95 100 93
NRB4 65X160 B 90 S4 302 16 65 80 100 360 200 280 210 950 900 25 255 95 100 92
NRB4 65X160 C 90 S4 302 16 65 80 100 360 200 280 210 950 900 25 255 95 100 92
NRB4 65X200 A 100 LB4 369 22 65 80 100 360 225 350 280 950 900 25 280 100 100 129
NRB4 65X200 B 100 LB4 369 22 65 80 100 360 225 350 280 950 900 25 280 100 100 129
NRB4 65X200 C 100 LA4 369 22 65 80 100 360 225 350 280 950 900 25 280 100 100 126
NRB4 65X250 A 112 MC4 386 22 65 80 100 470 250 400 330 1120 1070 25 310 110 125 181
NRB4 65X250 B 112 M4 386 22 65 80 100 470 250 400 330 1120 1070 25 310 110 125 181
NRB4 65X250 C 100 LB4 369 22 65 80 100 470 250 400 330 1120 1070 25 310 110 125 172
102
NRB4 80
PUMP PERFORMANCE
Nominal L/1' 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1800 2000 2250
Power VOLTAGE Amp. Q
CODE MODEL
HP kW
(V) 3 X 400 V m3/h 36 42 48 54 60 66 72 78 84 90 96 108 120 135
PA021510 NRB4 80X160 C 2 1,5 230/400 6,1 - 3,5 7,1 6,9 6,6 6,3 6 5,7 5,2 4,8
PA021520 NRB4 80X160 B 3 2,2 230/400 8,5 - 4,9 8,5 8,3 8,1 7,9 7,6 7,3 6,9 6,5 6,1 5,6
PA021530 NRB4 80X160 A 3 2,2 230/400 8,5 - 4,9 9,6 9,4 9,2 9 8,8 8,5 8,2 7,9 7,5 7,1 6,6
Discharge head
PA021540 NRB4 80X200 C 4 2,2 230/400 8,5 - 4,9 10,4 10 9,8 9,6 9 8,6 8 7,2 6,5
in meters
PA021550 NRB4 80X200 B 5,5 3 230/400 11,1 - 6,4 12,5 12,3 12,1 11,8 11,4 11 10,6 10 9,4 8,8 7,2
PA021560 NRB4 80X200 A 5,5 4 230/400 14,8 - 8,5 14,2 14 13,8 13,5 13,1 12,7 12,2 11,7 11,2 10,6 9,2 7,6
PA021570 NRB4 80X250 D 7,5 5,5 400 11,3 16,3 16 15,7 15,4 14,9 14,4 13,7 13 12,3 11,5
PA021580 NRB4 80X250 C 7,5 5,5 400 11,3 17,9 17,7 17,4 17 16,7 16,2 15,7 15 14,4 13,7 11,9
PA021590 NRB4 80X250 B 10 7,5 400 15 20,5 20,3 20 19,7 19,4 19 18,6 18,1 17,6 17 15,6 13,9
PA021600 NRB4 80X250 A 10 7,5 400 15 22,2 22 21,7 21,5 21,1 20,8 20,4 20 19,5 19 17,6 16,2 14
NRB4 80X160 A 100 LA4 369 22 80 100 125 360 225 350 280 950 900 25 280 100 100 127
NRB4 80X160 B 100 LA4 369 22 80 100 125 360 225 350 280 950 900 25 280 100 100 127
NRB4 80X160 C 90 L4 327 16 80 100 125 360 225 350 280 950 900 25 280 100 100 120
NRB4 80X200 A 112 M4 386 22 80 100 125 470 250 350 280 1120 1070 25 280 100 100 166
NRB4 80X200 B 112 M4 386 22 80 100 125 470 250 350 280 1120 1070 25 280 100 100 166
NRB4 80X200 C 100 LB4 369 22 80 100 125 470 250 350 280 1120 1070 25 280 100 100 156
NRB 4
NRB4 80X250 A 132 MA4 498 24 80 100 125 470 280 400 330 1120 1070 25 310 110 125 213
NRB4 80X250 B 132 MA4 498 24 80 100 125 470 280 400 330 1120 1070 25 310 110 125 213
NRB4 80X250 C 112 MC4 386 22 80 100 125 470 280 400 330 1120 1070 25 310 110 125 191
NRB4 80X250 D 112 MC4 386 22 80 100 125 470 280 400 330 1120 1070 25 310 110 125 191
103
NRB4 100
PUMP PERFORMANCE
Nominal L/1' 900 1000 1100 1200 1300 1400 1500 1600 1800 2000 2250 2500 2750 3000
Power VOLTAGE Amp.
CODE MODEL Q
HP kW
(V) 3 X 400 V m3/h 54 60 66 72 78 84 90 96 108 120 135 150 165 180
PA021610 NRB4 100X200 D 4 3 230/400 11,1 - 6,4 9,8 9,6 9,4 9,1 8,8 8,5 8,1 7,7 6,9 6
PA021620 NRB4 100X200 C 5,5 4 230/400 14,8 - 8,5 11,8 11,6 11,4 11,2 11 10,8 10,5 10,2 9,4 8,6 7,5
Discharge head
PA021630 NRB4 100X200 B 7,5 5,5 400 11,3 13,2 13,1 12,9 12,7 12,5 12,3 12 11,7 11,1 10,3 9,3 8,2
in meters
PA021640 NRB4 100X200 A 7,5 5,5 400 11,3 14,4 14,3 14,2 14 13,8 13,6 13,4 13,2 12,6 12 11 9,8 8,5
PA021680 NRB4 100X250 D 7,5 5,5 400 11,3 16,4 16,2 15,9 15,6 15,3 14,9 14,4 13,2 11,9 9,8
PA021660 NRB4 100X250 C 10 7,5 400 15 18 17,8 17,6 17,4 17,1 16,8 16,4 15,3 14,2 12,4 10,4
PA021670 NRB4 100X250 B 12,5 9,2 400 18 20,4 20,3 20,2 20 19,8 19,6 19,3 18,6 17,7 16,2 14,5 12,4
PA021650 NRB4 100X250 A 12,5 9,2 400 18 22 21,9 21,8 21,7 21,6 21,4 21,1 20,4 19,7 18,5 17 15 12,8
NRB4 100X200 A 112 MC4 386 22 100 125 125 470 280 400 330 1120 1070 25 310 110 125 188
NRB4 100X200 B 112 MC4 386 22 100 125 125 470 280 400 330 1120 1070 25 310 110 125 188
NRB4 100X200 C 112 M4 386 22 100 125 125 470 280 400 330 1120 1070 25 310 110 125 188
NRB4 100X200 D 100 LB4 369 22 100 125 125 470 280 400 330 1120 1070 25 310 110 125 179
NRB4 100X250 A 132 MB4 498 24 100 125 140 470 280 400 330 1120 1070 25 335 110 125 227
NRB4 100X250 B 132 MB4 498 24 100 125 140 470 280 400 330 1120 1070 25 335 110 125 227
NRB4 100X250 C 132 MA4 498 24 100 125 140 470 280 400 330 1120 1070 25 335 110 125 225
NRB4 100X250 D 112 MC4 386 22 100 125 140 470 280 400 330 1120 1070 25 335 110 125 203
104
NRI
BARESHAFT END-SUCTION CENTRIFUGAL PUMPS
NRI 32 NRI 40
CODE MODEL CODE MODEL
NRI 50
NRI 65
CODE MODEL
CODE MODEL
PA021790 NRI 50X120 C
PA021800 NRI 50X120 B PA021840 NRI 65X120 C
PA021810 NRI 50X120 A PA021850 NRI 65X120 B
PA021820 NRI 50X160 C PA021860 NRI 65X120 A
PA021830 NRI 50X160 B PA021870 NRI 65X160 C
PA020975 NRI 50X160 A PA020380 NRI 65X160 B
PA020240 NRI 50X200 C PA020370 NRI 65X160 A
PA020220 NRI 50X200 B PA020141 NRI 65X200 C
PA020080 NRI 50X200 A PA020170 NRI 65X200 B
PA020890 NRI 50X250 D PA020030 NRI 65X200 A
PA020920 NRI 50X250 C PA020970 NRI 65X250 C
PA020250 NRI 50X250 B PA020110 NRI 65X250 B
PA020160 NRI 50X250 A PA020300 NRI 65X250 A
NRI 80
CODE MODEL NRI 100
PA021880 NRI 80X160 C CODE MODEL
PA021890 NRI 80X160 B
PA020875 NRI 80X160 A PA021900 NRI 100X200 D
PA020885 NRI 80X200 C PA021910 NRI 100X200 C
PA020895 NRI 80X200 B PA021920 NRI 100X200 B
PA020905 NRI 80X200 A PA020760 NRI 100X200 A
PA020870 NRI 80X250 D PA021930 NRI 100X250 D
PA020910 NRI 80X250 C PA020730 NRI 100X250 C
NRI
105
CM
HORIZONTAL SINGLE-STAGE CENTRIFUGAL PUMPS
The CM series single impeller centrifugal pumps are silent and have a high hydraulic
efficiency.
• HIGH RELIABILITY
• STRONG AND RESISTANT
• HIGH HYDRAULIC PERFORMANCE
Applications
- Pumping from wells for irrigation
- Booster systems
- Domestic autoclaves
- Washing systems
DESIGN FEATURES
Component Material
1 Pump casing EN GJL 200 (ex G20) Cast iron
2 Motor bracket EN GJL 200 (ex G20) Cast iron
3 Impeller Brass (CM 90/22 in technopolymer)
5 Motor shaft X12 CrNiS 1809 (AISI 416) Stainless steel
7 Mechanical seal Graphite
8 Counterface Ceramic
10 O-ring NBR 70 shore
106
CM
TABLE OF HYDRAULIC PERFORMANCE
70
60
50
40
30
20
10
Hm
20 40 60 80 100 120 140 160
L / 1'
Q
m3/ h 2 4 6 8
PUMP PERFORMANCE
Nominal Absorbed
Power Power L/1' 10 30 50 80 100 120
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW m /h 0,6 1,8 3 4,8 6 7,2
N418B090 CM 90/22 M* 0,5 0,35 0,75 13 ~~ 220÷240
1 V 3,6 12,5 22 20 18 13
Discharge head
A B C D E F H1 H2 DNA DNM kg
CM 90/22 75 43 267 150 110 160 82 202 1" 1" 6,5
CM 100/36 82 44 310 180 140 185 107 242 1" 1" 11
CM
CM 110/44 88 45 350 194 155 200 100 252 1"1/4 1" 20,5
CM 130/51 88 45 350 220 180 225 115 286 1"1/4 1" 23
107
CB
TWIN IMPELLER CENTRIFUGAL PUMPS
The CB twin impeller centrifugal electric pumps have two self balanced impellers
to give very high efficiency. Particularly suitable for domestic and industrial
applications, booster sets etc.
Applications
– Booster systems
– Small-scale irrigation
– Non aggressive liquids transfer
– Washing systems
DESIGN FEATURES
Component Material
1 Pump casing EN GJL 200 (ex G20) Cast iron
108
CB
TABLE OF HYDRAULIC PERFORMANCE
80
70
210/7
6
60 190/6
7
50 110/ 16
5 5 0/6
12 8
0/
40 90/4 65
4
80/3
30 8
20
10
Hm
80 120 160 180 200 210
L / 1' 20 40 60 100 140
Q
1,2 2,4 3,6 4,8 6,0 7,2 8,4 9,6 10,8 11,6 12,0
m3/ h
PUMP PERFORMANCE
Nominal Absorbed
Power Power L/1' 20 40 50 80 90 100 110 140 170 190 210
CODE MODEL VOLTAGE Amp. µF. Q
HP kW HP kW m3/h 1,2 2,4 3,0 4,8 5,4 6,0 6,6 8,4 9,6 10,80 12,00
N4189050 CB 110/55 M V230/50 NP 1,5 1,10 2,5 1,9 1 ~ 220 V 10,8 35 50,8 48,8 47,1 38,4 33,4 27,5
N4189060 CB 110/55 T V230-400/50 NP 1,5 1,10 2,4 1,8 3 ~ 220 - 400 7,2 -4,1 35
N4189070 CB 120/65 M V230/50 NP 2 1,50 3,2 2,4 1 ~ 220 V 10,8 40
60,5 58,6 56,9 49,8 46,5 40,3 32,5
N4189080 CB 120/65 T V230-400/50 NP 2 1,50 3,0 2,3 3 ~ 220 - 400 7,2-4,1
N4189090 CB 160/68 T V230-400/50 NP 3 2,20 3,8 2,8 3 ~ 220 - 400 8,8-5,1 60,5 59,3 54,1 51,6 48,4 44,6 32,0
N4189100 CB 190/67 T V230-400/50 NP 4 3,00 5,7 4,2 3 ~ 220 - 400 13,0-7,5 67,0 64,8 63,9 62,5 62,0 58,0 53,5 48,0
N4189110 CB 210/76 T V230-400/50 NP 5 4,00 6,8 5,1 3 ~ 220 - 400 16,5-9,5 76,5 73,9 72,9 71,8 70,5 66,8 62,0 58,3 54,0
A B C D E F H1 H2 DNA DNM kg
CB 80/38 58 73 336 180 140 183 97 227 1" 1" 13,5
CB 90/44 58 73 336 180 140 183 97 227 1" 1" 15,0
CB 110/55 66 86 394 195 155 209 110 265 1"1/4 1" 25,0
CB 120/65 66 86 410 195 155 209 110 265 1"1/4 1" 27,0
CB 160/68 66 86 410 195 155 194 110 265 1"1/4 1" 27,0
CB
CB 190/67 72 96 467 230 180 228 133 309 1"1/2 1"1/4 42,5
CB 210/76 72 96 467 230 180 228 133 309 1"1/2 1"1/4 46,3
109
EP
PERIPHERAL PUMPS
The EP series peripheral monobloc pumps are especially suitable where high heads
with limited flow rates need to be developed.
• REDUCED DIMENSIONS
• LOW CONSUMPTION
Applications
- Small-scale booster systems
- Domestic autoclaves
- Small-scale irrigation
- Washing systems
DESIGN FEATURES
Component Material
Pump casing EN GJL 200(ex G20) Cast iron
Motor bracket EN GJL 200(ex G20) Cast iron
Impeller Brass
Motor shaft X12 CrNiS 1809 (AISI 416) Stainless steel
Mechanical seal Graphite
Counterface Ceramic
O-ring NBR 70 shore
110
EP
TABLE OF HYDRAULIC PERFORMANCE
70
60
50
40
4
30
2
20
10
Hm
10 20 30 40 50 60 70 80
L / 1'
Q
m3/ h 0,6 1,2 1,8 2,4 3 3,6 4,2 4,8
PUMP PERFORMANCE
Nominal Absorbed
Power Power L/1' 5 10 20 30 40 50 60
CODE MODEL VOLTAGE Amp. µF. Q
HP kW HP kW m3/h 0,3 0,6 1,2 1,8 2,4 3 3,6
N4162010F EP2 M 0,5 0,37 0,75 0,55 1 ~ 220÷240 V 2,2 10
Discharge
in meters
42 37 27 17 7
N4162020 EP2 T 3 ~ 230÷400 V 1,6-0,9
head
A B C D E DNA DNM kg
EP2 260 85 100 145 135 1" 1" 6,8
EP
111
SUBMERSIBLE PUMPS FOR OPEN AND DRILLED WELLS
PRATIKA
MULTISTAGE CENTRIFUGAL
SUBMERSIBLE PUMPS FOR CLEAR WATER
The PRATIKA submersible pumps are portable and ready to use for installation in
traditional wells, water deposits, collection tanks, clear watercourses, lakes etc.
Equipped with Ø 32 hose adapter.
Automatic version equipped with float switch.
Applications
- Pumping of water from traditional wells
- Domestic tank installations for boosting
domestic drinking water systems
- Small-scale automatic systems for
garden irrigation
- Surface irrigation
DESIGN FEATURES
Component Material
1
5
1 Pump body X 5 CrNi 1810 (AISI 304) Stainless steel
2 Suction grid X 5 CrNi 1810 (AISI 304) Stainless steel
3 Suction base X 5 CrNi 1810 (AISI 304) Stainless steel
8
4 Power cable 15 m H07 RN-F With schuko plug
7
Shaft (hydraulic end) X 5 CrNi 1810 (AISI 304) Stainless steel
6 5 with ceramic facing at the points of seal wear
6 Mechanical seal Graphite
7 Counterface Ceramic Oil chamber for
2
seal lubrication
9 8 Lip seal NBR 70 Rubber
10
9 Impeller Technopolymer
3
10 Diffuser Technopolymer
114
PRATIKA
TABLE OF HYDRAULIC PERFORMANCE
50
40
30 PR
ATI
K A
20
10
Hm
L / 1' 10 30 50 70 90 110
Q
m3/ h 0,6 1,8 3 4,2 6 8,8
PUMP PERFORMANCE
Nominal Absorbed
Power Power L/1' 0 20 40 60 80 100
CODE MODEL VOLTAGE Amp. µF. N˚ Q
3
HP kW HP kW Stadi m /h 0 1,2 2,4 3,6 4,8 6
* Start and stop level refers to the version equipped with floating switch
The minimum drainage level refers to the manual version
115
DOMINATOR 4
4” SUBMERSIBLE MULTISTAGE CENTRIFUGAL PUMP
FOR CLEAN WATER
The DOMINATOR 4” submersible pumps are suitable for istallation in traditional wells,
water deposits, collection tanks, clear watercourses, lakes etc.
Supplied with 20m nylon suspension cord.
10
12
11
DESIGN FEATURES
Component Material
1 Pump body X 5 CrNi 1810 (AISI 304) Stainless steel
2 Suction grid X 16 CrNi 16 (AISI 431) Stainless steel
3 Base Noryl
4 Impeller Acetal resin
5 Diffuser Polycarbonate with ceramic insert in the point of wear
Polycarbonate with stainless steel
6 Diffuser cap inserts in the point of wear
9
8 Hexagonal, in X 10 CrNiS 1809 (AISI 303)
1
7 Motor shaft stainless steel with ceramic
insert at the point of wear.
7 AISI 416 for the out of water parts.
6 8 Mechanical seal Graphite
5
9 Counterface Aluminum oxide
4
116
DOMINATOR 4
TABLE OF HYDRAULIC PERFORMANCE
60
50
115
/57
40
75
115/36 /56
30
75
/35
55
20
/5
0
10
Hm
10 20 30 40 50 60 70 80 90 100
L / 1'
Q
m3/ h 0,6 1,2 1,8 2,4 3,0 3,6 4,2 4,8 5,4 6,0
PUMP PERFORMANCE
Nominal Absorbed
Power Power L/1' 0 20 40 60 80
N˚
CODE MODEL VOLTAGE Amp. µF. Stages Q
3
HP kW HP kW m /h 0 1,2 2,4 3,6 4,8
N3200020 DOMINATOR 4” - 55/50 M 0,70 0,50 0,90 0,65 1 ~ 220 ÷ 240 V 3 16 6 50 38,7 17
Discharge head
N3200110 DOMINATOR 4” - 75/35 M 0,50 0,35 0,80 0,60 1 ~ 220 ÷ 240 V 3 12,5 5 35 33 26 11
in meters
N3200010 DOMINATOR 4” - 75/56 M 0,80 0,60 1 0,75 1 ~ 220 ÷ 240 V 3,3 16 8 56 49,8 38,1 19
N3200100 DOMINATOR 4” - 115/36 M 0,55 0,40 1 0,75 1 ~ 220 ÷ 240 V 3,5 12,5 5 36 35 32 25 13
N3200040 DOMINATOR 4” - 115/57 M 1 0,80 1,50 1,10 1 ~ 220 ÷ 240 V 5 16 8 57 52 44,4 31,5 16,6
DNM
DOMINATOR 4
117
DOMINATOR 5
SUBMERSIBLE MULTISTAGE CENTRIFUGAL PUMP
FOR CLEAR WATER
The DOMINATOR 5" submersible pumps are suitable for installation in traditional wells,
water deposits, collection tanks, clear watercourses, lakes etc.
Automatic version equipped with float switch.
Motor
- Dry motor with stainless steel casing
cooled by the pumped liquid
- Level of protection IP 68
- Class F insulation
- Single phase supply with capacitor
permanently activated
- Thermal protection built into the motor
winding
- Completely insulated cable connection
chamber
- Self-lubricating ball bearings
- Speed of rotation 2850 rpm
- Suitable for continuous use
DESIGN FEATURES
10
9
Component Material
7
1 Pump casing X 5 CrNi 1810 (AISI 304) Stainless steel
4 2 Suction grid X 5 CrNi 1810 (AISI 304) Stainless steel
5
6 4 Impeller X 5 CrNi 1810 (AISI 304) Stainless steel
5 Diffuser X 5 CrNi 1810 (AISI 304) Stainless steel
6 Spacer X 5 CrNi 1810 (AISI 304) Stainless steel
1 7 Motor shaft X CrNiMo 17-12-03 (AISI 316) Stainless steel
8 Power cable 20 m H07 RN-F with plug
2
9 Mechanical seal Graphite Oil chamber for
seal lubrication
10 Counterface Aluminium oxide
118
DOMINATOR 5
TABLE OF HYDRAULIC PERFORMANCE
70
60
50
140
40 /65
70
30 /5
0 140
70
/45
/75
20
10
Hm
20 40 60 80 100 120 140 160
L / 1'
Q
m3/ h 2 4 6 8
PUMP PERFORMANCE
Nominal Absorbed
Power Power L/1' 0 20 40 60 80 100 120 140
N˚
CODE MODEL VOLTAGE Amp. µF. Stages Q
3
HP kW HP kW m /h 0 1,2 2,4 3,6 4,8 6 7,2 8,4
N3191000 D 5” - 70/50 M 1 ~ 220 ÷ 240 V 4.5 16
N3191010 D 5” - 70/50 M AUT
N3191080 D 5” - 70/50 T 1 0.7 1.3 0.95 3 ~ 400 V 1.8 6 50.6 42.5 29.3 7.5
N3191150 D 5” - 70/50 T 3 ~ 230 V 3
Discharge head
119
SCM 4 Plus
4" MULTISTAGE CENTRIFUGAL SUBMERSIBLE PUMPS
COMPLETE WITH MOTOR
The SCM 4 PLUS submersible pumps consist of a multistage pumping unit directly
connected to a submersible motor.
Especially suitable for pumping from deep 4'' (100mm) Ø wells.
Motor Applications
- 4" submersible motor - Pumping of water from drilled wells
- Special resin impregnated sealed - Automatic systems for garden
stator irrigation
- Water-cooled thrust bearings and - Surface irrigation for agricultural use
bushes - Drinking water systems
- Approx. 1.5 m extendible power - Pumping and supply of stored
supply cable deposits or of booster autoclaves
- Non-polluting water cooling for civil and industrial systems
- 4" NEMA flange - Heat pumps
- Level of protection IP 58
- Class B insulation
- Speed of rotation 2850 rpm
- Special mechanical seal with sand
guard
- Pressure compensation diaphragm
- Supplied without capacitor (single
phase version)
- Suitable for continuous use
- Electrical control panel on request Usage limitations
- Type of liquid: clean non-aggressive,
non-explosive, free of solids
- Maximum liquid temperature 30° C
- Max. start-ups per hour 20
- Motor protection with thermal relay
provided by the user
DESIGN FEATURES
1
4 Component Material
11 1 Outlet X 5 CrNi 1810 (AISI 304) Microcast stainless steel
2 Suction flange X 5 CrNi 1810 (AISI 304) microcast stainless steel
3 Pump casing X 5 CrNi 1810 (AISI 304) Stainless steel
9 4 Check valve X 5 CrNi 1810 (AISI 304) Stainless steel
10
5 Cable protection trough X 5 CrNi 1810 (AISI 304) Stainless steel
8
6 Filter X 5 CrNi 1810 (AISI 304) Stainless steel
7
7 Impeller Acetal resin
5 3
8 Diffuser Polycarbonate with ceramic insert at the point of wear
9 Cap diffuser Polycarbonate with ceramic insert at the point of wear
120
SCM 4 Plus
Delivery connection Shaft guide bearing Floating impeller with Motor bracket and
point in microcast AISI made with a self- suction point shim on suction point in
304 stainless steel with lubricating closed bush stainless steel moulded microcast AISI 304
an internal tapered in molybdenum with a diffusor cover. stainless steel rigidly
double profile with a bisulphide polyamide Thrust bearing inserted welded to the outer
stainless steel non and stainless steel shaftbetween the hub of the stainless steel liner.
return valve and a with ceramic insert at impeller and diffusor Stainless steel suction
double slot for safety the point of wear. formed by one ceramic grid.
cable. ring moulded with the
BENEFITS: diffusor and a free ring BENEFITS:
BENEFITS: Increases the life of the in graphite. This system offers high
It resets flow resistance pump - protection "International Patent" resistance to
offering maximum against dry operation - mechanical stresses
rigidity and high high resistance to wear BENEFITS: caused by operating
resistance to protect the caused by sand. This extraordinary pressure.
pump against water technological innovation Maximum rigidity of the
hammering. leads to a large increase whole structure
in efficiency as well as eliminates vibrations.
high resistance to
abrasion by sand and
to dry operation.
SCM 4 Plus
121
SCM 4 Plus
TABLE FOR CALCULATING PUMP LENGTH
MODEL A B C
Pump DNM L Total
Total Motor Packing weight
length length length
mm. length Kg.
mm. mm.
96
SCM 4 PLUS 40/57 M 576 242 334 730 11.8
DNM
SCM 4 PLUS 40/57 T 557 223 334 710 10.8
SCM 4 PLUS 40/90 M 717 271 446 870 14.0
SCM 4 PLUS 40/90 T 688 242 446 840 12.7
SCM 4 PLUS 40/120 M 857 299 558 1010 16.1
SCM 4 PLUS 40/120 T 829 271 558 980 14.9
SCM 4 PLUS 40/185 M 1109 327 782 1260 19.2
SCM 4 PLUS 40/185 T 1081 299 782 1230 17.9
SCM 4 PLUS 40/240 M 1339 356 983 1490 22.2
SCM 4 PLUS 40/240 T 1310 327 983 1460 20.8
C
SCM 4 PLUS 55/50 M 509 242 267 660 11.3
SCM 4 PLUS 55/50 T 490 223 267 640 10.3
A
SCM 4 PLUS 55/80 M 628 271 357 780 13.1
SCM 4 PLUS 55/80 T 599 242 357 750 11.8
SCM 4 PLUS 55/105 M 700 299 401 850 14.9
SCM 4 PLUS 55/105 T 672 271 401 830 13.7
SCM 4 PLUS 55/160 M 862 327 535 1012 17.3
SCM 4 PLUS 55/160 T 834 299 535 990 16.0
SCM 4 PLUS 55/200 M 1026 356 670 1180 19.8
B
SCM 4 PLUS 55/200 T 997 327 670 1150 18.4
SCM 4 PLUS 55/300 T 1317 356 961 1470 22.3
SCM 4 PLUS 75/40 M 545 242 303 1" 1/4 700 11.2
105
SCM 4 PLUS 75/40 T 526 223 303 680 10.2
SCM 4 PLUS 75/56 M 631 271 360 780 12.9
SCM 4 PLUS 75/56 T 602 242 360 750 11.6
SCM 4 PLUS 75/75 M 744 299 445 900 14.8
SCM 4 PLUS 75/75 T 716 271 445 870 13.6
L
SCM 4 PLUS 75/110 M 915 327 588 1070 17.1
SCM 4 PLUS 75/110 T 887 299 588 1040 15.8
SCM 4 PLUS 75/140 M 1058 356 702 1200 19.4
SCM 4 PLUS 75/140 T 1029 327 702 1180 18.0
SCM 4 PLUS 75/210 T 1372 356 1016 1520 21.5
122
SCM 4 Plus 40
TABLE OF HYDRAULIC PERFORMANCE
The power curve refers to the brake horse power (BHP) per stage. % indicates the pump hydraulic efficiency
PUMP PERFORMANCE
Motor
power L/1' 10 20 30 40 Ø
CODE MODEL N˚ VOLTAGE Amp. µF. Q
Stages HP Kw m /h
3 DNM
0,6 1,2 1,8 2,4
123
SCM 4 Plus 55
TABLE OF HYDRAULIC PERFORMANCE
The power curve refers to the brake horse power (BHP) per stage. % indicates the pump hydraulic efficiency
PUMP PERFORMANCE
Motor
power L/1' 10 20 30 40 50 Ø
CODE MODEL N˚ VOLTAGE Amp. µF. Q
Stages HP Kw m /h
3
0,6 1,2 1,8 2,4 3 DNM
N3182100 SCM 4 PLUS-55/300 T 37 3 2,2 3 ~ 400 V 5,9 278 244 200 140 50
124
SCM 4 Plus 75
TABLE OF HYDRAULIC PERFORMANCE
The power curve refers to the brake horse power (BHP) per stage. % indicates the pump hydraulic efficiency
PUMP PERFORMANCE
Motor
power L/1' 20 30 40 50 60 Ø
CODE MODEL N˚ VOLTAGE Amp. µF. Q
Stages HP Kw m /h 3
1,2 1,8 2,4 3 3,6 DNM
5,3 30
N3183050 SCM 4 PLUS-75/75 T 11 1 0,75 3 ~ 400 V 67 62 55 45 30
2,1
in meters
N3183100 SCM 4 PLUS-75/210 T 30 3 2,2 3 ~ 400 V 5,9 186 170 155 130 80
125
SCM 4 Plus 115
TABLE OF HYDRAULIC PERFORMANCE
The power curve refers to the brake horse power (BHP) per stage. % indicates the pump hydraulic efficiency
PUMP PERFORMANCE
Motor
power L/1' 30 40 50 60 80 90 100 Ø
CODE MODEL N˚ VOLTAGE Amp. µF. Q
Stages HP Kw m /h
3
1,8 2,4 3 3,6 4,8 5,4 6 DNM
N3184100 SCM 4 PLUS-115/185 T 24 3 2,2 3 ~ 400 V 5,9 160 153 143 130 85 58 31
N3184110 SCM 4 PLUS-115/245 T 33 4 3 3 ~ 400 V 7,8 218 210 198 179 118 84 47
126
SCM 4 Plus 150
TABLE OF HYDRAULIC PERFORMANCE
The power curve refers to the brake horse power (BHP) per stage. % indicates the pump hydraulic efficiency
PUMP PERFORMANCE
Motor
power L/1' 40 50 60 80 100 120 140 Ø
CODE MODEL N˚ VOLTAGE Amp. µF. Q
Stages HP Kw m /h
3
2,4 3 3,6 4,8 6 7,2 8,4 DNM
N3185000 SCM 4 PLUS-150/42 M 1 ~ 230 V 5,3 30
38 37 36 33 26 17 10
N3185010 SCM 4 PLUS-150/42 T 6 1 0,75 3 ~ 400 V 2,1
N3186170 SCM 4 PLUS-150/42 T 3 ~ 230 V 3,7
N3185020 SCM 4 PLUS-150/64 M 1 ~ 230 V 7,8 40
59 58 57 50 39 27 15
N3185030 SCM 4 PLUS-150/64 T 9 1,5 1,1 3 ~ 400 V 3,2
N3186180 SCM 4 PLUS-150/64 T 3 ~ 230 V 5,2
SCM 4 Plus
N3185070 SCM 4 PLUS-150/170 T 24 4 3 3 ~ 400 V 7,8 160 157 152 134 106 69 30
N3185080 SCM 4 PLUS-150/200 T 29 5,5 4 3 ~ 400 V 10 191 188 179 152 112 71 32
N3185090 SCM 4 PLUS-150/300 T 42 7,5 5,5 3 ~ 400 V 13,7 292 290 285 252 210 155 82
127
SCM 4 Plus 250
TABLE OF HYDRAULIC PERFORMANCE
The power curve refers to the brake horse power (BHP) per stage. % indicates the pump hydraulic efficiency
PUMP PERFORMANCE
Motor
power L/1' 100 120 140 180 200 220 240 Ø
CODE MODEL N˚ VOLTAGE Amp. µF. Q
Stages HP Kw 13,2 14,4 DNM
3
m /h 6 7,2 8,4 10,8 12
N3186000 SCM 4 PLUS-250/53 M 1 ~ 230 V 9,9 50
N3186010 SCM 4 PLUS-250/53 T 9 2 1,5 3 ~ 400 V 43 41 37 26 18 11 4
4
N3186200 SCM 4 PLUS-250/53 T 3 ~ 230 V 6,9
Discharge head
N3186050 SCM 4 PLUS-250/185 T 31 7,5 5,5 3 ~ 400 V 13,7 152 141 127 81 57 36 18
128
SCM 4 HF 400
4” MULTISTAGE CENTRIFUGAL SUBMERSIBLE
PUMPS COMPLETE WITH MOTOR
SCM 4HF 400 high flow rate submersible pumps consist of a multistage hydraulic end
directly connected to a submersible motor. Especially suitable for pumping from deep
Ø 4” (100 mm) wells
Motor
– 4” submersible motor
– Special resin impregnated sealed stator
– Water-cooled thrust bearings and
bushes
– Approx. 1,5 m extendible power supply Applications
cable
– Non-polluting water cooling – Pumping of water from drilled wells
– 4” NEMA flange – Automatic systems for garden irrigation
– Level of protection IP58 – Surface irrigation for agricultural use
– Class B insulation – Drinking water systems
– Speed of rotation 2850 rpm – Pumping and supply of stored deposits
– Special mechanical seal with sand or of booster autoclaves for civil and
guard industrial systems
– Pressure compensation diaphragm – Heat pumps
– Supplied without capacitor (single
phase version)
– Suitable for continuous use
– Electrical control panel on request
Usage limitations
- Type of liquid: clean, non aggressive,
non-explosive, free of solids
- Maximum liquid temperature 30° C
- Max. start-ups per hour 20
- Motor protection with thermal relay
provided by the user
9
DESIGN FEATURES
Component Material
1 Outlet 300 grades stainless steel - 2” BSP
2 Suction flange Microcast stainless steel (300 grades)
8 3 Pump casing 300 grades stainless steel
7 4 Cable protection trough 300 grades stainless steel
6
5 Filter 300 grades stainless steel
3
4
6 Impeller 20% fibreglass reinforced Polycarbonate
Diffusor 20% fibreglass reinforced Noryl®
7
Thrust ring inserted in every stage
2
8 Motor shaft (hydraulic end) Hexagonal in stainless steel (300 grades)
5 9 Delivery bearing Acetal resin and stainless steel
(produced with self lubricating closed bushing)
- Intermediate bearing Acetal resin and stainless steel
129
SCM 4 HF 400
4” MULTISTAGE CENTRIFUGAL SUBMERSIBLE PUMPS COMPLETE WITH MOTOR
TABLE OF HYDRAULIC PERFORMANCE
CAPACITY U.S. GALLONS PER MINUTE
0 20 40 60 80 100
120 400
100
400
TOTAL HEAD IN METERS
400/50
40
400/30 100
20
0
0 50 100 150 200 250 300 350 400
CAPACITY LITRES PER MINUTE
PUMP PERFORMANCE
Motor L/1' 100 150 200 250 300 350
CODE MODEL Power VOLTAGE Amp. µF. N˚ Q
HP kW stages m3/h 6 9 12 15 15 21
N3186110 SCM4HF 400/50 T 3 2,2 3 ~ 400 V 5,9 11 43 39,2 35,5 31,1 25,1 19,2
96
DNM
C
A
130
SCM 4 Plus / HF PUMP-END
SUBMERSIBLE PUMPS
131
SCM 4 Plus / HF PUMP-END
SUBMERSIBLE PUMP
N1050300 SCM 4 PLUS 150/200 191 188 179 152 112 71 32 HP 5,5
N1050310 SCM 4 PLUS 150/300 292 290 285 252 210 255 82 HP 7,5
CODE MODEL Ql/1' 100 120 140 180 200 220 240 NECESSARY
MOTOR
NECESSARY
CODE MODEL Ql/1' 100 150 200 250 300 350 MOTOR
Discharge head in meters
132
MOTORS 4”
4” SUBMERSIBLE MOTORS FOR SCM 4 PLUS
NEMA SPEC WITH PART ELECTRICAL CABLE
POWER VOLTAGE
CODE Hz
HP kW
222P0390-C 0,5 0,37 1 ~ 230V 50
POWER VOLTAGE
CODE Hz
HP kW
221P0030 0,5 0,37 3 ~ 400V 50
221P1010 4 3 3 ~ 400V 50
133
SA
6" MULTISTAGE SUBMERSIBLE PUMPS COMPLETE
WITH MOTOR
Motor Applications
- 6" Franklin submersible motor - Civil and industrial supply systems
- Special resin impregnated sealed stator - Overhead or surface irrigation
- Water-cooled thrust bearings and - Boosting
bushes - Firefighting
- Approx. 1.5 m extendible power supply - Various civil and industrial applications
cable - Mains water supply systems
- Non-polluting water cooling - Heat pumps
- 6" NEMA flange
- Level of protection IP58. Class F
insulation
- Speed of rotation 2850 rpm
- Special mechanical seal with sand Usage limitations
guard
- Pressure compensation diaphragm - Type of liquid: clean non-aggressive,
- Suitable for continuous use non-explosive, free of solids
- Electrical control panel on request - Maximum liquid temperature 30° C
- Direction of rotation anticlockwise - Max. start-ups per hour: 15
(seen from the delivery end) - Motor protection with thermal relay
provided by the user
- Maximum quantity of sand present:
40 g/m3
DESIGN FEATURES
Component Material
Outlet EN GJS 400 (GS400) Nodular cast iron
Suction flange EN GJS 400 (GS400) Nodular cast iron
Outer liner Stainless steel
Cable protection filter and trough Stainless steel
Shaft Stainless steel
Impeller Technopolymer/Polycarbonate.
SA 615 - SA 625: radial impellers
SA 630 - SA 650: semiaxial impellers
Diffuser Noryl GNF 2V
Wear rings Stainless steel
Bush bearings Bronze/rubber
134
SA 615
TABLE OF HYDRAULIC PERFORMANCE
145
DNM
L1
L
Ø MOTOR
DNM = 3” gas
Pump Ø
Model casing Motor Electric pump
L1 L Weight
(mm) (mm) (mm) (kg)
SA 615/4 435 87 791 22
SA 615/5 478 87 901 27
SA 615/6 511 87 1056 30
SA 615/9 625 87 1329 41
SA 615/12 738 137 1384 58
The power curve refers to the brake horse power (BHP) per stage. % indicates the pump hydraulic efficiency
SA 615/18 966 137 1677 67
PUMP PERFORMANCE
Motor
Power L/1' 0 120 160 200 230 260 300
N.
CODE MODEL Stages VOLTAGE Amp. Q
3
HP kW m /h 0 7,2 9,6 12 13,8 15,6 18
D8763KKK SA 615/9* 9 7,5 5,5 3 ~ 400 V 13,7 140 134 123 113 101 88 70
D8764KKK SA 615/12 12 10 7,5 3 ~ 400 V 16 187 179 166 152 136 118 92
SA
D8765KKK SA 615/18 18 15 11 3 ~ 400 V 23,3 281 268 250 231 210 180 138
* WITH 4’’ MOTOR
135
SA 625
TABLE OF HYDRAULIC PERFORMANCE
145
DNM
L1
L
Ø MOTOR
DNM = 3” gas
Pump Ø
Model casing Motor Electric pump
L1 L Weight
(mm) (mm) (mm) (kg)
SA 625/4 511 87 1056 30
SA 625/6 625 87 1329 41
SA 625/8 738 137 1384 57
SA 625/12 966 137 1677 66
SA 625/16 1193 137 1969 75
SA 625/20 1474 137 2316 86 The power curve refers to the brake horse power (BHP) per stage. % indicates the pump hydraulic efficiency
PUMP PERFORMANCE
Motor
power L/1' 0 200 300 350 400 500 600
N.
CODE MODEL Stages VOLTAGE Amp. Q
3
HP kW m /h 0 12 18 21 24 30 34
D8775KKK SA 625/16 16 20 15 3 ~ 400 V 31,3 243 212 190 177 159 118 67
D8776KKK SA 625/20 20 25 18,5 3 ~ 400 V 38,5 304 265 238 220 198 146 84
* WITH 4’’ MOTOR
136
SA 630
TABLE OF HYDRAULIC PERFORMANCE
145
DNM
L1
L
Ø MOTOR
DNM = 3” gas
Pump Ø
Model casing Motor Electric pump
L1 L Weight
(mm) (mm) (mm) (kg)
SA 630/4 522 87 1226 39
SA 630/5 582 137 1228 54
SA 630/8 762 137 1473 62
SA 630/10 882 137 1658 70
SA 630/12 1002 137 1844 78 The power curve refers to the brake horse power (BHP) per stage. % indicates the pump hydraulic efficiency
PUMP PERFORMANCE
Motor
power L/1' 0 300 400 500 600 700 800
N.
CODE MODEL VOLTAGE Amp. Q
Stages 3
HP kW m /h 0 18 24 30 36 42 48
D8786KKK SA 630/12 12 25 18,5 3 ~ 400 V 38,5 188 171 160 143 122 92 55
* WITH 4’’ MOTOR
137
SA 650
TABLE OF HYDRAULIC PERFORMANCE
145
DNM
L1
L
Ø MOTOR
DNM = 3” gas
Pump Ø
Model casing Motor Electric pump
L1 L Weight
(mm) (mm) (mm) (kg)
SA 650/4 522 137 1168 53
SA 650/6 642 137 1353 61
SA 650/9 822 137 1598 69
SA 650/10 882 137 1724 76
SA 650/12 1002 137 1909 84
The power curve refers to the brake horse power (BHP) per stage. % indicates the pump hydraulic efficiency
PUMP PERFORMANCE
Motor
power L/1' 0 600 700 800 900 1000 1100
N.
CODE MODEL VOLTAGE Amp. Q
Stages 3
HP kW m /h 0 36 42 48 54 60 66
138
SA PUMP-ENDS
6” SUBMERSIBLE PUMPS
CODE MODEL Ql/1' 0 120 160 200 230 260 300 NECESSARY
MOTOR
N1051300 SA 615/4 * 62 60 55 51 46 39 31 HP 3
CODE MODEL Ql/1' 0 200 300 350 400 500 600 NECESSARY
MOTOR
CODE MODEL Ql/1' 0 300 400 500 600 700 800 NECESSARY
MOTOR
N1051430 SA 630/5 78 72 67 59 50 37 23 HP 10
CODE MODEL Ql/1' 0 600 700 800 900 1000 1100 NECESSARY
MOTOR
N1051470 SA 650/4 54 40 35 31 25 19 13 HP 10
Discharge head in meters
N1051480 SA 650/6 81 59 53 46 37 29 20 HP 15
139
6” MOTORS
ELECTRIC MOTORS Ø 6” FOR SUBMERSIBLE PUMPS
NEMA SPEC WITH PART ELECTRICAL CABLE
POWER
CODE VOLTAGE Hz
HP kW
221P0830-C 15 11 3 ~ 400V 50
221P0840-C 20 15 3 ~ 400V 50
WATER COOLED
221P0890-C 30 22 3 ~ 400V 50
2
ZA000420 CABLE 4 x 1 NEOPRENE HO7 RNF 4 WIRE CABLE 1 MM WIRES
2
ZA000430 CABLE 4 x 1,5 NEOPRENE HO7 RNF 4 WIRE CABLE 1,5 MM WIRES
2
ZA000440 CABLE 4 x 2,5 NEOPRENE HO7 RNF 4 WIRE CABLE 2,5 MM WIRES
ZA000450 CABLE 4 x 4 NEOPRENE HO7 RNF 4 WIRE CABLE 4 MM
2
WIRES
ZA000460 CABLE 4 x 6 NEOPRENE HO7 RNF 4 WIRE CABLE 6 MM
2
WIRES
ZA000470 CABLE 4 x 10 NEOPRENE HO7 RNF 4 WIRE CABLE 10 MM WIRES
2
ZA003370 JOINT KIT 2,5 HEAT-SHRINK SPLICING KIT FOR CABLES UP TO 4 X 2,5
ZA003390 JOINT KIT 6 HEAT-SHRINK SPLICING KIT FOR CABLES UP TO 4 X 6
ZA003380 JOINT KIT 10 RESIN FILLED SPLICING KIT
ZA009410 JOINT 2,5 HEAT-SHRINK SPLICING JOINT FOR CABLES UP TO 1 - 2,5 mmq
ZA009430 JOINT 6 HEAT-SHRINK SPLICING JOINT FOR CABLES UP TO 4 - 6 mmq
ZA009450 JOINT 10 RESIN FILLED SPLICING JOINT FOR CABLES UP TO 4 X 10 mmq
140
SELECTION OF ELECTRIC CABLE FOR SUBMERSIBLE PUMPS
Direct starting
3 ~ 400 V - 50 Hz
1 four - pole cable
MOTOR 4 x …mm2
1.5 2.5 4 6 10
KW
Cables - L max in m.
0.37 777
0.55 523
0.75 384
1.1 262
1.5 192 320
2.2 131 218 349
3 96 160 256 385
4 72 120 192 289
5.5 52 88 140 210 351
7.5 64 103 154 258
9.2 52 84 126 210
11 70 106 176
13 60 90 149
15 130
18.5 105
22 89
1 ~ 220 ÷ 240 V - 50 Hz
1 four - pole cable
4 x …mm2
MOTOR
1.5 2.5 4 6 10
kW
3 ~ 230 V - 50 Hz
Cables - max L in m. 1 four - pole cable
4 x …mm2
0.37 114 191 305 MOTOR
1.5 2.5 4 6 10
kW
0.55 77 128 205 308
141
DRAINAGE AND SEWAGE PUMPS
DP
SUBMERSIBLE PUMPS FOR DRAINING CLEAR WATER
The DP series submersible pumps for clear water have been designed for domestic
applications as drainage of seepage water, pumping of water from wells, water deposits
and collection tanks. Equipped with 25-32 Ø rubber holder. The float level switch
enables the pump to work automatically.
Applications
- Drainage of seepage water, pumping of
rain water from a grating or drain
- Draining of environments, tanks and
wells
3
DESIGN FEATURES
5
Component Material
1
6 1 Pump body Technopolymer
2
2 Impeller Technopolymer
3 Motor casing X 8 CrNi 18-10 (AISI 304) Stainless steel
4 Power cable 10 m H05 RN-F with plug
144
DP
TABLE OF HYDRAULIC PERFORMANCE
180
/7
4
Hm
20 40 60 80 100 120 140 160
L / 1'
Q
m3/ h 1,2 2,4 3,6 4,8 6 7,2 8,4 9,6
PUMP PERFORMANCE
Absorbed
power L/1' 0 25 50 100 150
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW m /h 0 1,5 3 6 9
N1041190 DP 130/6
Discharge
in meters
* Start and stop level refers to the version equipped with floating switch
The minimum drainage level refers to the manual version
145
SIMER “SIMO” PUMP
SUBMERSIBLE PUMP FOR DRAINING CLEAR WATER
The SIMO submersible pump for clear water has been designed for domestic applications
as drainage of seepage water, pumping of water from sump pits, water deposits and
collection tanks.
Equipped with 13-19-25 Ø adaptable connector.
Applications
- Drainage of seepage water, pumping of
rain water from grating or drain
- Emptying of water deposits, collection
tanks and wells.
DESIGN FEATURES
Component Material
Pump body Die cast aluminium
Impeller Die cast zinc
Motor casing Die cast aluminium
Power cord H07RN-F 10m cable (rapid clutch)
Motor shaft X 12 CrS 13 (AISI 416) Stainless steel
Seal Graphite
Counterface Ceramic
O-ring Nitrile
146
SIMER “SIMO” PUMP
TABLE OF HYDRAULIC PERFORMANCE
SIM
ER
SIM
4 OP
UM
P
Hm
10 20 30 40 50 60
L / 1'
Q
m3/ h 0,6 1,2 1,8 2,4 3 3,6
PUMP PERFORMANCE
Absorbed
Power L/1' 4 21 40 55
CODE MODEL VOLTAGE Q
3
HP kW m /h 0,2 1,3 2,4 3,3
Discharge
OD6601G-02 SIMER SIMO PUMP 0,55 0,4 1 ~ 230 V head 6,1 4,6 3 1,5
in meters
DNM
147
DPC
SUBMERSIBLE PUMP FOR DRAINING CLEAR WATER
The DPC pump has been designed for domestic applications as drainage of seepage
water, pumping of water from sump pits, water deposits or collection tanks. Equipped
with rubber holder for 3/4 or 25-32 Ø hoses and check valve.
• COMPACT
• INTEGRATED FLOAT SWITCH
• MANUAL-AUTOMATIC SELECTOR
• MINIMUM DRAINAGE LEVEL 3mm
Applications
- Drainage of seepage water, pumping of
rain water from a grating or drain
- Draining of environments, tanks and
wells
DESIGN FEATURES
Component Material
6
1 Pump body Technopolymer
2 Suction base Technopolymer
5
4
1 3 Impeller Technopolymer
8
4 Power cable 10 m H05 RN-F With schuko plug
7
5 Motor casing X 8 CrNi 18-10 (AISI 304) Stainless steel
3
6 Motor shaft X 8 CrNi 18-9 (AISI 304) Stainless steel
7 Mechanical seal Graphite
2
8 Counterface Ceramic Oil chamber for seal lubrication
9 Secondary seal NBR rubber
148
DPC
TABLE OF HYDRAULIC PERFORMANCE
12
10
8 200
/10
Hm
20 40 60 80 100 120 140 160
L / 1'
Q
m3/ h 1,2 2,4 3,6 4,8 6 7,2 8,4 9,6
PUMP PERFORMANCE
Absorbed
power L/1' 0 50 100 120 160
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW m /h 0 3 6 7,2 9,6
Discharge
N1080110 DPC 200/10 0,87 0,65 1 ~ 230 V 2,9 8 head 10 8 6 4,6 2,2
in meters
A B C D E F DNM kg
DPC 200/10 273 148 200 170 97 63 1" 1/4 5,6
149
DRENOX
SUBMERSIBLE SUMP PUMPS FOR DRAINING
CLEAR WATER
The DRENOX series pumps are built entirely in AISI 304 stainless steel. Cooling of the
motor is via a heat exchange chamber that allows the machine to work for long periods
when not completely submerged.
Equipped with Ø 32 mm hose adapter.
Automatic version equipped with float switch.
Applications
- Drainage of seepage water, pumping
of rain water, from a grating or drain,
pumping of domestic waste
water, drainage of environments,
bathing and swimming pools, industrial
applications
- Fountains and water features
- Surface irrigation
Motor
- Dry motor with stainless steel casing
- Level of protection IP68
- Class F insulation
Usage limitations - Single phase power supply with
capacitor
- Type of liquid: partially effluent and dirty permanently activated and thermal
clear water, non-aggressive liquids protection built into the motor winding
- Maximum liquid temperature 40°C - Three phase power supply with
- Maximum submersion under the water external protection provided by the
level 7m user
- Minimum drainage level 3 mm for model - Completely insulated cable connection
80/7, 35 mm for the other models chamber
(manual version) - Self-lubricating ball bearings
- Free clearance of solids 3 mm for - Speed of rotation 2850 rpm
models 80/7,
6 mm for the other models
DESIGN FEATURES
Component Material
1 Pump body X 5 CrNi 1810 (AISI 304) Stainless steel
1
5
2 Suction grid X 5 CrNi 1810 (AISI 304) Stainless steel
3 Impeller X 5 CrNi 1810 (AISI 304) Cast stainless steel
4 Power cable 10 m H07 RN-F with plug
6
150
DRENOX
TABLE OF HYDRAULIC PERFORMANCE
12
10
350
8 /12
250
/10
6
16
0/8
4
80
/7
Hm
50 100 150 200 250 300
L / 1'
Q 18
m3/ h 3 6 9 12 15
PUMP PERFORMANCE
Nominal Absorbed
power power L/1' 10 40 60 80 120 160 240 300
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW m /h 0,6 2,4 3,6 4,8 7,2 9,6 14,4 18
N1031090 DRENOX 80/7 0,3 0,2 0,4 0,3 1 ~ 220 ÷ 240 V 1,3 6,3 5,4 3,3 1,8
N1031100 DRENOX 80/7 AUT
DRENOX
N1031020 DRENOX 160/8 0,55 0,40 0,75 0,55 1 ~ 220 ÷ 240 V 2,4 8 7 5,8 5 4,1 2,2
N1031060 DRENOX 160/8 AUT
Discharge
in meters
N1031030 DRENOX 250/10 0,75 0,55 1,2 0,9 1 ~ 220 ÷ 240 V 4,5 10 9,4 8,5 7,6 7,2 5,1 4,0 1
head
151
DRENOX
DRENOX 80/7
* Start and stop level refers to the version equipped with floating switch
The minimum drainage level refers to the manual version
152
DRENOX
A B ØC D E* F* G* DNM kg
DRENOX 160/8 300 94 177 182 35 320 107 ø6 1" 1/4 6,5
DRENOX 350/12 338 94 177 182 35 351 111 ø6 1" 1/4 8,5
* Start and stop level refers to the version equipped with floating switch
The minimum drainage level refers to the manual version
153
DPV
SUBMERSIBLE PUMP FOR DRAINING DIRTY WATER
The DPV pump has been designed for domestic applications, to move waste water
with solids of a maximum dimension of 25 mm and for the emptying of dirty water
collection tanks. It is equipped with Ø 32 rubber holder. Automatic version equipped
with float switch.
Applications
- Drainage of domestic dirty water
- Draining of environments, tanks and
wells
3
5
1
DESIGN FEATURES
6
Component Material
2
1 Pump casing Technopolymer
2 Impeller Technopolymer
3 Motor casing X 8 CrNi 18-10 (AISI 304) Stainless steel
4 Power cable 10 m H05 RN-F with plug
154
DPV
TABLE OF HYDRAULIC PERFORMANCE
16
4 0/6
Hm
20 40 60 80 100 120 140 160
L / 1'
Q
m3/ h 1,2 2,4 3,6 4,8 6 7,2 8,4 9,6
PUMP PERFORMANCE
Absorbed
power L/1' 0 20 60 80 100
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW m /h 0 1,2 3,6 4,8 6
155
OMNIA
SUBMERSIBLE SUMP PUMPS FOR DIRTY WATER
The OMNIA series pumps are made entirely of AISI 304 stainless steel. Cooling of the
motor is via a heat exchange chamber that allows the machine to work for long periods
when not completely submerged. Equipped with Ø 32mm hose adapter.
Automatic version equipped with float switch.
Applications
- Pumping of domestic waste water,
draining of environments, bathing and
swimming pools, industrial applications
- Fountains and water features
- Surface irrigation
Motor
- Dry motor with stainless steel casing
- Level of protection IP68
- Class F insulation
Usage limitations - Single phase power supply with
capacitor permanently activated
- Type of liquid: waste water with solids - Thermal protection built into the motor
- Maximum liquid temperature 40°C winding
- Maximum submersion under the water - Completely insulated cable connection
level 7m chamber
- Minimum drainage level 35 mm - Self-lubricating ball bearings
(manual) - Speed of rotation 2850 rpm
- Free clearance of solids 20 mm
DESIGN FEATURES
Component Material
1 Pump body X 5 CrNi 1810 (AISI 304) Stainless steel
1 2 Suction base X 5 CrNi 1810 (AISI 304) Stainless steel
5
3 Impeller X 5 CrNi 1810 (AISI 304) Stainless steel
7 4 Power cable 10 m H07 RN-F with plug
6
5 Motor shaft X 12 CrNiS 1809 (AISI 416) Stainless steel
3
6 Seal Fixed double NBR 70 rubber lip seal.
2 Oil chamber for seal lubrication.
7 Outlet 1" 1/4 gas male threaded
156
OMNIA
TABLE OF HYDRAULIC PERFORMANCE
20
0/8
16
0/7
4
80
/5
PUMP PERFORMANCE
Nominal Absorbed
power power L/1' 10 40 70 100 140 200
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW m /h 0,6 2,4 4,2 6 8,4 12
157
OMNIA
OMNIA 80/5 264 94 177 182 35 250 100 Ø 20 1" 1/4 6,1
158
PRIOX
SUBMERSIBLE EFFLUENT VORTEX PUMPS FOR
DIRTY WATER
The PRIOX series pumps are made entirely of AISI 304 stainless steel. They work
completely submerged in the pumped liquid that cools the motor externally. Manufactured
on the vortex operating principle with the impeller set back.
Automatic version equipped with float switch.
Applications Motor
– All applications of pumping and draining – Dry motor
effluent, civil and industrial sewage – Level of protection IP 68
with suspended solids – Class F insulation
– Pumping stations with one or more – Single phase power supply with
pumps for civil and industrial plants capacitor permanently activated
and thermal protection built into
the motor winding
– Three phase power supply with
external protection under care
of the user (control panel on request)
– Completely insulated cable connection
chamber
– Self-lubricating ball bearings
– Speed of rotation 2850 rpm
Usage limitations
– Type of liquid: waste water and sewage
with solids
– Maximum liquid temperature 40°C.
– Maximun submersion under the water
level 7m
– Minimum drainage level 60 mm
(manual version)
– Free clearance of solids: 40 mm
50mm (PRIOX 600/13 - PRIOX 800/18)
6
5 DESIGN FEATURES
Component Material
1 Pump body X 5 CrNi 1810 (AISI 304) Stainless steel
7
2 Suction base X 5 CrNi 1810 (AISI 304) Stainless steel
3 Impeller X 5 CrNi 1810 (AISI 304) Cast stainless steel
4 Outlet Threaded
11
10 5 Cover Cast stainless steel (Priox 800/18)
6 Power cable 10 m H07 RN-F with plug
4
1
3
7 Motor shaft X 12 CrNiS 1809 (AISI 416) Stainless steel
8 Mechanical seal Silicum carbide
9 9 Counterface Oil chamber for
Silicum carbide seal lubrication
8 10 Secondary seal NBR rubber lip seal
2 11 V-ring sand guard NBR rubber
159
PRIOX
TABLE OF HYDRAULIC PERFORMANCE
20
18
16
14
12 80
0/1
8
10
60
8
0/1
46 3
0/1
42 3
6 0/1
1
30
4 0/9
25
0/8
2
Hm
L / 1' 100 200 300 400 500 600 700
Q
m3/ h 6 12 18 24 30 36 42
PUMP PERFORMANCE
Nominal Absorbed L/1' 50 100 150 200 250 300 400 500 550 600 650
power power
Amp. µF. Q
3
CODE MODEL HP kW HP kW VOLTAGE m /h 3 6 9 12 15 18 24 30 33 36 39
N2110100 PRIOX 250/8 M 1 ~ 230 V 3,6 14 6,5 5,2 3,4 2,0 0,2
0,75 0,55 1,1 0,8
N2110110 PRIOX 250/8 M AUT
N2110040 PRIOX 300/9 M
0,8 0,6 1,2 0,9 1 ~ 230 V 4,1 12,5 7,7 6,4 5 3,8 2,3 1
N2110050 PRIOX 300/9 M AUT
N2110090 PRIOX 300/9 T 0,8 0,6 1,2 0,9 3 ~ 400 V 1,55 7,7 6,4 5 3,8 2,3 1
Discharge head
N2110060 PRIOX 600/13 T 1,6 1,2 2,4 1,8 3 ~ 400 V 3 12,8 12,2 11,3 10,3 9,3 8 5,5 3 1,8
N2110130 PRIOX 800/18 T 3,2 2,4 4 3 3 ~ 400 V 5,5 17,3 16,5 15,6 14,7 13,7 12,7 10,5 8 6,7 5,4 4
160
PRIOX
PRIOX 250/8 420 122,5 235 241 63 550 290 Ø 40 1"1/2 9,4
PRIOX 300/9 420 122,5 235 241 63 550 290 Ø 40 2" 9,6
PRIOX 420/11 450 122,5 235 241 63 580 320 Ø 40 2" 11,2
PRIOX
PRIOX 460/13 450 122,5 235 241 63 580 320 Ø 40 2" 11,7
PRIOX 600/13 450 122,5 235 241 63 580 320 Ø 50 2" 12,6
161
MINIVORT P
SUBMERSIBLE SEWAGE PUMPS WITH VORTEX IMPELLER
The MINIVORT P pumps are made entirely of cast iron and designed for continuous
use in fixed installations. Manufactured on the vortex operating principle with the
impeller set back.
Strong and resistant.
Applications Motor
- Pumping and draining effluent; - Dry motor
civil and industrial sewage with - Level of protection IP68
suspended solids - Class F insulation
- Draining of cesspits, cesspools, - Single phase power supply with
handling of effluent capacitor permanently activated
- Pumping stations with one or more and thermal protection built into
pumps for civil and industrial plants the motor winding
- Three phase power supply with
external protection provided
by the user
- Self-lubricating ball bearings
- Speed of rotation 2850 rpm
- Four pole 1450 rpm (P2) motor (P4).
Usage limitations
- Type of liquid: waste water and sewage
- Maximum liquid temperature 40°C
- Maximum submersion under the water
level 7m
- Minimum drainage level 45mm
(manual version)
- Free clearance of solids 52 mm
Design features
- Automatic single phase version with float switch and sealed electric panel including
capacitor, thermal protection and manual/automatic switch. 10 m H07 RN-F power
supply cable
- Three phase version, 10 m H07 RN-F power supply cable
- Flanged outlet connection, with square threaded counterflange - 2" female
DESIGN FEATURES
Component Material
Pump body EN GJL 200 (ex G20) Grey cast iron
Motor casing EN GJL 200 (ex G20) Grey cast iron
Base EN GJL 200 (ex G20) Grey cast iron
Impeller EN GJL 200 (ex G20) Grey cast iron
Motor shaft X 12 CrNiS 1809 (AISI 416) Stainless steel
Mechanical seal
Oil chamber for
Counterface Ceramic seal lubrication
Lip seal NBR 70 rubber
162
MINIVORT P
TABLE OF HYDRAULIC PERFORMANCE
14
12
10
P2
-2
8
P2
- 1,
6 5
P4 - 1 P2 -
1
4
Hm
L / 1' 100 200 300 400 500 600 700
Q
m3/ h 6 12 18 24 30 36 42
PUMP PERFORMANCE
Nominal Absorbed
power power L/1' 50 100 200 300 400 500
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW m /h 3 6 12 18 24 30
N2041010 MINIVORT P2 - 1 M 1 ~ 220 ÷ 240 V 6,5 20
N2041020 MINIVORT P2 - 1 M AUT 1 0,75 2 1,5 1 ~ 220 ÷ 240 V 6,5 20 6 5,4 4,1 3 1
N2041030 MINIVORT P2 - 1 T 3 ~ 400 V 2,3
N2042010 MINIVORT P2 - 1,5 M 1 ~ 220 ÷ 240 V 7 25
Discharge head
N2042020 MINIVORT P2 - 1,5 M AUT 1,5 1,1 2,2 1,6 1 ~ 220 ÷ 240 V 7 25 8,3 7,5 6,1 4,6 2,8 1
in meters
DNM
D
MINIVORT P2 - 2 45 440 85 235 2" 28
163
MINIVORT PP
SUBMERSIBLE SEWAGE PUMPS WITH VORTEX IMPELLER
The MINIVORT PP pumps are made entirely of cast iron and designed for continuous
use in fixed installations. Manufactured on the vortex operating principle with the
impeller set back.
Motor Applications
- Dry motor - Pumping and draining effluent; civil and
- Level of protection IP68 industrial sewage with suspended
- Class F insulation solids
- Single phase power supply with - Draining of cesspits, cesspools,
capacitor permanently activated handling of effluent
and thermal protection built into - Pumping stations with one or more
the motor winding pumps for civil and industrial plants
- Three phase power supply with - On request, connecting foot to make
external protection provided installations and maintenance easier
by the user
- Self-lubricating ball bearings
- Speed of rotation 2850 rpm
DESIGN FEATURES
Component Material
1 Pump casing EN GJL 200 (ex G20) Grey cast iron
6 2 Motor casing EN GJL 200 (ex G20) Grey cast iron
7
8
3 Base EN GJL 200 (ex G20) Grey cast iron
2
4 Impeller EN GJL 200 (ex G20) Grey cast iron
4 5 Power cable 10 m H07 RN-F
1
6 Motor shaft X 12 CrNiS 1809 (AISI 416) Stainless steel
3
7 Mechanical seal Graphite
8 Counterface Ceramic Oil chamber for
seal lubrication
- Lip seal NBR 70 rubber
164
MINIVORT PP
TABLE OF HYDRAULIC PERFORMANCE
12
10
PP
8 2-
2
6
PP
2-
1,5
PP
4 2-
1
Hm
L / 1' 100 200 300 400 500 600 700 800 900
Q
m3/ h 6 12 18 24 30 36 42 48 54
PUMP PERFORMANCE
Nominal Absorbed
power power L/1' 100 200 300 400 600 800
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW m /h 6 12 18 24 36 48
N2051010 MINIVORT PP2 - 1 M 1 ~ 220 ÷ 240 V 6,2 20
N2051020 MINIVORT PP2 - 1 M AUT 1 0,75 2 1,5 1 ~ 220 ÷ 240 V 6,2 20 5 4 3 1,6
Discharge head
DNM
Model
A
A B C D DNM kg
MINIVORT PP2 - 1 72 475 115 325 2 1/2" 30 D
165
FG
SUBMERSIBLE PUMPS FOR WASTE WATER
Identification name
FG T 50 1,5 M 2 AUT
2
4 N˚ of poles
6
M Single-phase
T Three-phase
50 -150 DN outlet in mm
FG Series
Selection table
Nominal L/1' 0 25 50 75 100 125 150 175 185,5 200 212,5 225 250 275 300 325
MODEL Power Q
kW HP m3/h 0 1,5 3 4,5 6 7,5 9 10,5 11,1 12 12,7 13,5 15 16,5 18 19,5
1,1 1,5 15,2 14,1 12,9 11,4 10 8,5 6,9 5,2 4,3 3,6
Discharge head
FGT 50 1,5 M2
in meters
FGT 50 1,5 M2 AUT 1,1 1,5 15,2 14,1 12,9 11,4 10 8,5 6,9 5,2 4,3 3,6
FGT 50 2 T2 1,5 2 20 19,6 18,9 18 17 16 14,7 13,2 12,6 11,7 11 10 8,1 6,2 4,2
FGT 50 2,5 T2 1,8 2,5 25 24,5 23,9 23,1 22,3 21,5 20,5 19,4 18,8 18,1 17,5 16,9 15,5 13,9 12 10
Nominal L/1' 0 50 100 200 300 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400
MODEL Power Q
kW HP m3/h 0 3 6 12 18 24 36 48 60 72 84 96 108 120 132 144
FGV 65 1,5 T4 1,1 1,5 8,5 8,4 8,3 8 7,4 6,5 4,4
FGV 65 2,5 T4 1,8 2,5 9 8,8 8,7 8,3 7,8 7,2 5,4
FGV 65 2,5 T2 1,8 2,5 15,6 15,4 14,9 13,6 11,9 10 5,9
FGV 65 3 T2 2,2 3 18 17,6 17 15,6 14 12,2 8,3
FGV 80 4 T4 3 4 8 7,4 7,1 6,8 6,2 5,6 4,9 4,1 3,3
FGV 80 5 T4 3,7 5 9,5 8,9 8,5 8,1 7,4 6,5 5,6 4,6 3,5
Discharge head
Nominal L/1' 0 300 600 900 1200 1800 2400 3000 3600 4200 4800 5400 6000 6600 7200 7800
MODEL Power Q
3
kW HP m /h 0 18 36 54 72 108 144 180 216 252 288 324 360 396 432 468
FGC 150 7,5 T6 5 7,5 13 11 9,8 9 8,5 7,5 6,8 4,8 1,8
Discharge head
FGC 150 10 T6 7,5 10 15 13,6 12,8 12 10,3 8,5 6,6 4,7 3,2
in meters
166
FG
SUBMERSIBLE PUMPS FOR WASTE WATER
Performance range
FG
FGV 100
FGT 50 FGV 80
FGC 150
FGV 65
Total manometric head in m
Capacity
Application table
APPLICATIONS
Rain Sewage Mixed Grey Waste Grey Non Recycled Livestock Industrial Sewage Liquids
filtered filtered filtered clean domestic waters filtered or active slurries slurries waters with
MODEL waters waters waters waters waters mixed sludges with clogging
Impeller waters solids and
and filamenting
fibres fibres
Cutter plate
FGT 50
impeller
FGV 65 Vortex
FGV 80 Vortex
167
FGT
SUBMERSIBLE PUMPS FOR WASTE WATER
CUTTER PLATE IMPELLER
These high pressure pumps are designed to transfer solids through small bore pipework
water with solids in suspension.
Max diam. 38 mm, without long fibres
Made in high quality engineering cast iron
High efficency open impeller with high resistance stainless steel four-knives intake
cutting system.
Applications Motor
- Contamined water - Dry chamber motor – insulation
- Sewage with fibres class F.
- Industrial waste and animal slurry - IP68 protection
chemically compatible with the - Motor electric supply voltage:
pump construction materials. three-phase 3x400V 50Hz,
single-phase 1x230V 50Hz
- Rotor supported by long-life
self-lubricated rolling bearings.
- Winding protection by means of a
sealed chamber, filled with oil, which
is fitted between pump and motor.
Usage limitations Dynamic oil seal ensured by two
mechanical seals.
- Max temperature of pumped liquid: - Single-phase version with thermal
40°C protection and condensers placed in
- Max immersion depth: 20 m proper box with contact breaker
- Running positioning: only vertical allowing starting also when knives
- Outlet nominal diameter: 2” gas cause overload conditions.
- For continuous operation, within the - Single-phase models are available
allowed use limits, the submersible in two versions:
pump must be submerged for 2/3 Automatic starting with float switch
of its height, at least. Direct starting without float switch
- Suitable for fixed installation, with rapid - Max startings per hour: 30
coupling device or more portable
applications suspended or rested.
Free passage: 5 mm
DESIGN FEATURES
Component Material
Pump casing EN GJL 200
Impeller EN GJL 200
Motor shaft AISI 420 stainless steel
Motor casing EN GJL 200
Mechanical seal (pump side) Silicon carbide/Silicon carbide
Mechanical seal (motor side) Ceramic/Graphite
OR gasket NBR rubber
Blade AISI 440C stainless steel
Cable lock Brass
Cable 10 m H07RN - F
168
FGT
42
41
39
40
FGT 50
1 Handle 16 Cable lock washer 31 Radial seal
2 Screw 8 x 40 17 Cable lock rubber ring 32 Impeller
3 Nut 8MA 18 Earthing cable screw 33 Nut 12 MA
4 Screw 6 x 12 19 Earthing cable terminal 34 Diffuser
5 Cover 20 O-Ring 35 Suction strainer
6 O-Ring 21 Intermediate flange 36 Compensating washer
7 Identification plate 22 O-Ring 37 Blade
8 Screw 8 x 50 23 Lower bearing 38 Impeller washer
9 Motor body 24 Die-stock flange 39 Impeller grower washer
10 Upper bearing 25 Upper mechanical seal (fixed ring) 40 Screw 6 x 20
11 Stator 26 Upper mechanical seal (rotating ring) 41 Screw 6 x 14
12 Shaft with rotor 27 O-Ring 42 Screw 6 x 16
FGT
169
FGT 50
SUBMERSIBLE PUMPS FOR WASTE WATER - CUTTER PLATE IMPELLER
TABLE OF HYDRAULIC PERFORMANCE
H
m
26
24
22
FG
20 T5
02
,5 T
18
2
16 FG
T5
02
14 T2
12
FG
T5
10 01
,5
M
8 2
6
l/min 0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 375 400
Q l/s 0 1.6 3.3 5 6.6
m /h 0 3 6 9 12 15 18 21 24
3
170
FGT 50
SUBMERSIBLE PUMPS FOR WASTE WATER - CUTTER PLATE IMPELLER
PUMP PERFORMANCE
Nominal Absorbed Voltage Rated L/1' 0 50 75 100 150 200 250 300 325
CODE MODEL power power current n Q
HP kW HP kW V A µF min -1 m3/h 0 3 4,5 6 9 12 15 18 19,5
N2160010 FGT 50 1,5 M2 1,5 1,1 1,81 1,35 1˜ 230 8 20+40 2820 15,2 12,9 11,4 10 6,9 3,6
Discharge head
in meters
N2160020 FGT 50 1,5 M2 AUT 1,5 1,1 1,81 1,35 1˜ 230 8 20+40 2820 15,2 12,9 11,4 10 6,9 3,6
N2160030 FGT 50 2 T2 2 1,5 3,49 2,6 3˜ 400 6 - 2800 20 18,9 18 17 14,7 11,7 8,1 4,2
N2160040 FGT 50 2,5 T2 2,5 1,8 3,49 2,6 3˜ 400 6,4 - 2830 25 23,9 23,1 22,3 20,5 18,1 15,5 12 10
G N
B
A
D
H
E
I P
L Q
FGT 50 1,5 M2 445 145 270 Ø 2” 110 80 Ø 3/4” Ø 2” 110 150 410 38 140 100 130 38 5
FGT 50 1,5 M2 AUT 445 145 270 Ø 2” 110 80 Ø 3/4” Ø 2” 110 150 410 38 140 100 130 38 5
FGT
FGT 50 2 T2 445 145 270 Ø 2” 110 80 Ø 3/4” Ø 2” 110 150 410 38 140 100 130 39 5
FGT 50 2,5 T2 445 145 270 Ø 2” 110 80 Ø 3/4” Ø 2” 110 150 410 38 140 100 130 40 5
171
FGV
SUBMERSIBLE PUMPS FOR WASTE WATER
VORTEX IMPELLER
Applications Motor
- Sewage with suspended solids - Dry chamber motor – insulation
including long fibres. class F
- For liquid mixing in stock tanks, for - IP68 protection
industrial waste and animal slurry with - Motor electric supply voltage:
solids in suspension. three-phase 3x400V 50Hz
- Starting: D.O.L till 5,5 kW
Star/delta since 5,5 kW
- Rotor supported by long-life
self-lubricated rolling bearings
- Winding protection by means of a
Usage limitations sealed chamber, filled with oil, which
is fitted between pump and motor.
- Max temperature of pumped liquid: Dinamic oil seal ensured by two
40°C mechanical seals
- Max immersion depth: 20 m - Max startings per hour:
- PH: between 6-11 30 FGV 65
- Running positioning: only vertical 20 FGV 80
- Outlet nominal diameter: 20 <= 5,5 kW – 15 > 5,5 kW FGV100
DN65 FGV 65
DN80 FGV 80
DN100 FGV 100
- For continuous operation, within the
allowed use limits, the submersible
pump must be submerged for 2/3
of its height, at least.
- Suitable for fixed installation with
coupling foot, guide rails and chain,
or more portable applications
suspended or rested.
- Free passage: 62 mm FGV 65
50-80 mm FGV 80
83-98 mm FGV 100
DESIGN FEATURES
Component Material
Pump casing EN GJL 200
Impeller EN GJL 200
Motor shaft AISI 420 stainless steel
Motor casing EN GJL 200
Mechanical seal (pump side) Silicum carbide/Silicum carbide
FGV 65 EPDM rubber
Mechanical seal (motor side) FGV 80 Carbon/Alumina
FGV 100 Carbon/Steel
OR gasket NBR rubber
Cable lock Brass
Cable 10 m H07RN - F
172
FGV
FGV 100
1 Shackles 16 Upper bearing 31 Impeller
2 Screw 10 x 25 17 Shaft with rotor 32 Impeller spacer
3 Identification plate 18 Impeller key 33 Nut 16 MA
4 Cover 19 Internal retaining ring 34 Gasket
5 O-Ring 20 Lower bearing 35 Counterflange 4” PN16 DN 100
6 O-Ring 21 External retaining ring 36 Screw 16 x 70
7 H07RN-F Cable 22 O-Ring 37 Pump body
8 Cable lock 23 Die-stock flange 38 Foot pedestal
9 Cable lock washer 24 Upper mechanical seal (fixed ring) 39 Screw 10 x 35
10 Cable lock rubber ring 25 Upper mechanical seal (rotating ring) 40 Screw 8 x 25
11 Motor body 26 Washer 41 Impeller grower washer
12 Screw 12 x 80 27 O-Ring 42 Screw 8 x 12
FGV
173
FGV 65
SUBMERSIBLE PUMPS FOR WASTE WATER - VORTEX IMPELLER
TABLE OF HYDRAULIC PERFORMANCE
4 POLES
H
m
10
8
FGV
65 2
7 FGV ,5 T
65 1 4
,5 T
6 4
l/min 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800
Q l/s 0 2.5 5 7.5 10 12.5
m /h 0
3
3 6 9 12 15 18 21 24 27 30 33 36 39 42 45 48
2 POLES
H
m
20
18
16
14
FGV
65
12 3T
2
10 FG
V6
52
,5 T
8 2
6
l/min 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800
Q l/s 0 2.5 5 7.5 10 12.5
m /h 0
3
3 6 9 12 15 18 21 24 27 30 33 36 39 42 45 48
174
FGV 65
SUBMERSIBLE PUMPS FOR WASTE WATER - VORTEX IMPELLER
PUMP PERFORMANCE
Nominal Absorbed Voltage Rated L/1' 0 100 200 300 400 500 600 650 700
CODE MODEL power power current n Q
HP kW HP kW V A min -1 m3/h 0 6 12 18 24 30 36 39 42
N2150010 FGV 65 1,5 T4 1,5 1,1 2,35 1,75 3˜ 400 3,3 1400 8,5 8,3 8 7,4 6,5 5,4 4,4
Discharge head
in meters
N2150020 FGV 65 2,5 T4 2,5 1,8 3,35 2,5 3˜ 400 4,5 1425 9 8,7 8,3 7,8 7,2 6,4 5,4 4,8 4,3
N2150030 FGV 65 2,5 T2 2,5 1,8 3,49 2,6 3˜ 400 4,5 2838 15,6 14,9 13,6 11,9 10 8 5,9 4,8
N2150040 FGV 65 3 T2 3 2,2 4,44 3,31 3˜ 400 5,4 2840 18 17 15,6 14 12,2 10,3 8,3 7,2
H I
E L R
A
G UNI 2253
M
F
N
D
C
B
O T
P U
Q V
1 1
FGV 65 2,5 T2 515 273 217 90 158 62 Ø2” /2 80 190 Ø 3/4 530 Ø2” /2 110 150 418 38 140 100 130 228 40 62
1 1
FGV 65 3 T2 515 273 217 90 158 62 Ø2” /2 80 190 Ø 3/4 530 Ø2” /2 110 150 418 38 140 100 130 228 47 62
175
FGV 80
SUBMERSIBLE PUMPS FOR WASTE WATER - VORTEX IMPELLER
TABLE OF HYDRAULIC PERFORMANCE
4 POLES
H
m
10
8
FGV
7 80 5
FGV T4
6 80 4
T4
5 FGV
80 3
4
T4
l/min 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800
Q l/s 0 1.6 3.3 5 6.6 8.3 10 11.6 13.3 15 16.6 18.3 20 21.6 23.3 25 26.6 28.3 30
m /h 0
3
6 12 18 24 30 36 42 48 54 60 66 72 78 84 90 96 102 108
H 2 POLES
m
26
24
22
20
FGV
18 80 7
,5 T
16
2
FG
14 V8
FG 06
12 V8 T2
05
10 FG T2
V8
8 04
T2
6
l/min 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600
Q l/s
3
0 1.6 3.3 5 6.6 8.3 10 11.6 13.3 15 16.6 18.3 20 21.6 23.3 25 26.6
m /h 0 6 12 18 24 30 36 42 48 54 60 66 72 78 84 90 96
176
FGV 80
SUBMERSIBLE PUMPS FOR WASTE WATER - VORTEX IMPELLER
PUMP PERFORMANCE
Nominal Absorbed Voltage Rated L/1' 0 200 400 500 600 800 1000 1100 1200 1300 1400 1500
CODE MODEL power power current n Q
HP kW HP kW V A min -1 m3/h 0 12 24 30 36 48 60 66 72 78 84 90
N2150220 FGV 80 3 T4 3 2,2 6,55 4,8 3˜ 400 5,6 1440 6 5,6 5,1 4,8 4,4 3,8 3,1 2,8 2,4 2,1
N2150050 FGV 80 4 T4 4 3 7,66 5,71 3˜ 400 7,4 1440 8 7,4 6,8 6,5 6,2 5,6 4,9 4,5 4,1 3,7 3,3 2,8
N2150060 FGV 80 5 T4 5 3,7 7,71 5,75 3˜ 400 8,8 1445 9,5 8,9 8,1 7,8 7,4 6,5 5,6 5 4,6 4,1 3,5 3
Discharge head
N2150070 FGV 80 4 T2
in meters
4 3 6,64 4,95 3˜ 400 6,5 2830 15,4 13,2 10,8 9,3 8 5,4
N2150080 FGV 80 5 T2 5 3,7 7,78 5,8 3˜ 400 8,5 2890 18,7 17,5 15,3 14 12,6 9,4 6,2
N2150090 FGV 80 6 T2 6 4,4 9,68 7,22 3˜ 400 10 2910 22,3 20,4 17,9 16,6 15,2 12,8 10 8,8 7,5 6,3 5
N2150100 FGV 80 7,5 T2 7,5 5,5 9,04 6,74 3˜ 400 12 2900 25 23,4 21,9 21 20,2 18,5 16,5 15,3 14 12,5
H K
L M
O
A
G UNI 2254
P
Q
F
R
D
T
S
C
B
U V
I W
J X
FGV 80 5 T4 620 315 270 125 185 82 Ø 3” 353 110 422 330 175 180 Ø 2” Ø 3” Ø160 480 700 220 375 240 150 390 638 76 80
FGV 80 4 T2 620 365 270 125 203 67 Ø 3” 353 110 422 330 175 180 Ø 2” Ø 3” Ø160 480 700 220 375 240 150 390 638 70 67
FGV 80 5 T2 620 365 270 125 203 67 Ø 3” 353 110 422 330 175 180 Ø 2” Ø 3” Ø160 480 700 220 375 240 150 390 638 72 67
FGV
FGV 80 6 T2 620 365 270 125 203 67 Ø 3” 353 110 422 330 175 180 Ø 2” Ø 3” Ø160 480 700 220 375 240 150 390 638 74 67
FGV 80 7,5 T2 620 365 270 125 203 67 Ø 3” 353 110 422 330 175 180 Ø 2” Ø 3” Ø160 480 700 220 375 240 150 390 638 76 50
177
FGV 100
SUBMERSIBLE PUMPS FOR WASTE WATER - VORTEX IMPELLER
TABLE OF HYDRAULIC PERFORMANCE
4 - 6 POLES
H
m
20
18
16
14
FG
12 V1
FG 00
V1 10
10 00 T4
7T
8
4
FGV 1
00 6,5
6 T6
4
l/min 0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200
Q l/s 0 3.3 6.6 10 13.3 16.6 20 23.3 26.6 30 33.3 36.6 40 43.3 46.6 50 53.3
m3 /h 0 12 24 36 48 60 72 84 96 108 120 132 144 156 168 180 192
2 POLES
H
m
40
38
36
34 FGV
100 2
32 0 T2
30
28
26
24 FGV 1
22 00 15
20
T2
18
FGV 1
00 10
16 T2
14
12
10
8
6
4
2
l/min 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800
Q l/s 0 1.6 3.3 5 6.6 8.3 10 11.6 13.3 15 16.6 18.3 20 21.6 23.3 25 26.6 28.3 30
m3 /h 0 6 12 18 24 30 36 42 48 54 60 66 72 78 84 90 96 102 108
178
FGV 100
SUBMERSIBLE PUMPS FOR WASTE WATER - VORTEX IMPELLER
PUMP PERFORMANCE
Nominal Absorbed Voltage Rated L/1' 0 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400
CODE MODEL Power power current n Q
HP kW HP kW V A min -1 m3/h 0 24 36 48 60 72 84 96 108 120 132 144
N2150110 FGV 100 6,5 T6 6,5 4,8 8,21 6,12 3˜ 400 11 965 9,5 8,8 8,4 79 7,4 6,8 6,1 5,4 4,6 3,7 2,8 1,9
N2150120 FGV 100 7 T4 7 5 8,85 6,6 3˜ 400 12 1450 14,1 12,6 11,5 10,2 9 7,7 6,3 5,1 4
Discharge head
in meters
N2150130 FGV 100 10 T4 10 7,5 16,09 12 3˜ 400 Y/∆ 20 1450 17 16 15,3 14,8 13,8 12,9 11,9 10,9 9,9 8,8 7,8 6,8
N2150140 FGV 100 10 T2 10 7,5 15,82 11,8 3˜ 400 Y/∆ 21 2915 24 20,5 18,3 16,2 14,2 12,3 10,4
N2150150 FGV 100 15 T2 15 11 18,10 13,5 3˜ 400 Y/∆ 23 2890 31 25,8 23,8 22 20 18,2 16
N2150160 FGV 100 20 T2 20 15 23,60 17,6 3˜ 400 Y/∆ 31 2920 40 36,6 34,3 32 29,8 27,6 25
H I L
M N O
T UNI 2254
R
G UNI 2254
A
Q
F
U
S
V W
D
C J X
B
K Y
FGV 100 6,5 T6 774 410 366 227 225 100 Ø 4” 300 355 110 520 410 185 225 200 Ø 2” 774 547 227 Ø 4” 420 280 180 460 730 143 98
FGV 100 7 T4 774 410 366 227 225 100 Ø 4” 300 355 110 520 410 185 225 200 Ø 2” 774 547 227 Ø 4” 420 280 180 460 730 143 98
FGV 100 10 T4 774 410 366 227 225 100 Ø 4” 300 355 110 520 410 185 225 200 Ø 2” 774 547 227 Ø 4” 420 280 180 460 730 158 98
FGV 100 10 T2 774 410 366 227 225 100 Ø 4” 300 355 110 520 410 185 225 200 Ø 2” 774 547 227 Ø 4” 420 280 180 460 730 142 83
FGV
FGV 100 15 T2 874 410 366 227 225 100 Ø 4” 300 355 110 520 410 185 225 200 Ø 2” 874 647 227 Ø 4” 420 280 180 460 730 160 83
FGV 100 20 T2 874 410 366 227 225 100 Ø 4” 300 355 110 520 410 185 225 200 Ø 2” 874 647 227 Ø 4” 420 280 180 460 730 200 83
179
FGC
SUBMERSIBLE PUMPS FOR WASTE WATER
SINGLE CHANNEL IMPELLER
Applications Motor
- Sewage, effluent and rainwaters without - Dry chamber motor – insulation
long fibres class F
- Animal slurry, industrial water with - IP68 protection
solids in suspension of max diameter - Motor electric supply voltage:
of 108 mm according to pumps size three-phase 3x400V 50Hz
- Starting: star/delta
- Rotor supported by long-life
self-lubricated rolling bearings
- Winding protection by means of a
sealed chamber, filled with oil, which
Usage limitations is fitted between pump and motor.
Dynamic oil seal ensured by two
- Max temperature of pumped liquid: mechanical seals.
40°C - Max startings per hour: 15
- Max immersion depth: 20 m
- PH: between 6-11
- Running positioning: only vertical
- Outlet nominal diameter: DN150
- For continuous operation, within the
allowed use limits, the submersible
pump must be submerged for 2/3
of its height, at least.
- Suitable for fixed installation with
coupling foot, guide rails and chain,
or more portable applications
suspended or rested.
- Free passage: 95-108 mm.
DESIGN FEATURES
Component Material
Pump casing EN GJL 250
Impeller EN GJL 250
Motor shaft AISI 420 stainless steel
Motor casing EN GJL 250
Mechanical seal (pump side) Silicum carbide / Silicum carbide
Mechanical seal (motor side) Ceramic / Graphite
OR gasket NBR rubber
Cable lock Brass
Cable 10 m H07RN - F
180
FGC
15 Earthing cable screw 6 x 8 32 Seal housing flange 49 Lower mechanical seal (fixed ring)
16 Motor body 33 Nut M20 50 Teflon washer
17 Screw 12 x 55 34 Screw 20 x 70 51 Screw 8 x 12
181
FGC 150
SUBMERSIBLE PUMPS FOR WASTE WATER - SINGLE CHANNEL IMPELLER
TABLE OF HYDRAULIC PERFORMANCE
H 6 POLES
m
16
FGC
150
10 T
6
FG
C1
50
7,5
T6
l/min
Q l/s
3
m /h
H 4 POLES
ft m
FG FGC
C1 150
50 30 T
20 4
T4
FG
C1
50
15
T4
l/min
Q l/s
3
m /h
182
FGC 150
SUBMERSIBLE PUMPS FOR WASTE WATER - SINGLE CHANNEL IMPELLER
PUMP PERFORMANCE
Nominal Absorbed Voltage Rated L/1' 0 600 1200 1800 2400 3000 3600 4200 4800 6000 6600 7200
CODE MODEL power power current n Q
-1 3
HP kW HP kW V A min m /h 0 36 72 108 144 180 216 252 288 360 396 432
N2150170 FGC 150 7,5 T6 7,5 5 8,45 6,3 3˜ 400 Y/∆ 12 950 13 9,8 8,5 7,5 6,8 4,8 1,8
Discharge head
N2150180 FGC 150 10 T6 10 7,5 8,45 6,3 3˜ 400 Y/∆ 19 950 15 13,6 12 10,3 8,5 6,6 4,7 3,2
in meters
N2150190 FGC 150 15 T4 15 11 20,79 15,5 3˜ 400 Y/∆ 26 1450 17 16 14,9 13,2 11,8 10 8,1 6,5
N2150200 FGC 150 20 T4 20 15 25,48 19 3˜ 400 Y/∆ 31 1450 20 18 16 14 12,7 11,6 11 10 8,5
N2150210 FGC 150 30 T4 30 22 33,53 25 3˜ 400 Y/∆ 46 1450 34,3 30 26,2 23,9 21,5 19,5 18 16,2 15,2 12,3 11 9,5
J X
K L
M
E
N
F G
S UNI 2254
P
Q
A
I UNI 2254
T
R
H
D
U
B
V
C W Y
FGC 150 7,5 T6 950 190 590 301 602 240 362 150 DN 150 810 240 570 70 Ø 2” 229 650 970 320 DN 150 450 70 300 1100 105 275 200 95
FGC 150 10 T6 1150 190 590 317 657 271 386 150 DN 150 871 271 600 70 Ø 2” 229 835 1155 320 DN 150 450 70 300 1174 105 275 300 108
FGC 150 15 T4 950 190 590 301 602 240 362 150 DN 150 810 240 570 70 Ø 2” 229 650 970 320 DN 150 450 70 300 1100 105 275 212 95
FGC
FGC 150 20 T4 950 190 590 301 602 240 362 150 DN 150 810 240 570 70 Ø 2” 229 650 970 320 DN 150 450 70 300 1100 105 275 226 95
FGC 150 30 T4 1150 190 590 317 657 271 386 150 DN 150 871 271 600 70 Ø 2” 229 835 1155 320 DN 150 450 70 300 1174 105 275 340 108
183
Accessories
184
VACUSYSTEM
MINI COLLECTION AND PUMPING STATIONS FOR
WASTE WATER
Usage limitations
- Type of liquid: partially effluent and dirty
clear water, with suspended solids of
a maximum dimension of 6 mm,
non-aggressive liquids
- Maximum liquid temperature 40°C
Design features
- The standard pumping station consists of:
- Tank
In polyethylene with a capacity of 85 litres with corrosion and wear resistant sand
filter bowl and grid. Three possible types of 40 Ø pipe inlet.
- Flexible pipe 1 1/4" helically wound complete with a sleeve for the connection of
the delivery pipe for both right-hand and left-hand connection
- Non return valve
- Plug
with built in thermal protection and switch for manual/automatic operation.
- DRENOX automatic submersible pump
Component Material
Pump body X 5 CrNi 1810 (AISI 304) Stainless steel
Suction grid X 5 CrNi 1810 (AISI 304) Stainless steel
Impeller X 5 CrNi 1810 (AISI 304) Cast stainless steel
Power cable 10 m H07 RN-F with plug
186
VACUSYSTEM
TABLE OF HYDRAULIC PERFORMANCE
12
10
8
250
/10
6 16
0/8
Hm
L / 1' 50 100 150 200 250 300
Q
m3/ h 3 6 9 12 15 18
PUMP PERFORMANCE
Nominal Absorbed
power power L/1' 10 40 60 80 120 160
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW m /h 0,6 2,4 3,6 4,8 7,2 9,6
N2141000 VS 85-D 160 0,5 0,37 0,6 0,45 1 ~ 220 ÷ 240 V 2,2 8 Discharge 7 5,8 5 4,1 2,2
head
in meters
N2141010 VS 85-D 250 0,75 0,55 1,2 0,9 1 ~ 220 ÷ 240 V 4,5 10 9,4 8,5 7,6 7,2 5,1 4,1
VS 85-D 160 300 250 503 620 50 85 130 505 45 570 400 200 600 485 250 40 21,4
VS 85-D 250 300 250 503 620 50 85 130 505 45 570 400 200 600 485 250 40 22,5
187
VACUSYSTEM
COLLECTION AND PUMPING STATIONS FOR
DIRTY WATER
Usage limitations
- Type of liquid: water with suspended
solids of a maximum dimension
of 40 mm
- Maximum liquid temperature 40°C
- Minimum drainage level 60 mm
Design features
The standard pumping station consists of:
- Tank
in polyethylene with a capacity of 175 l.
The closing lid is supplied with O-ring.
It warrants liquid seal and possible gas locks.
- DN 110 inlet, 2” outlet and DN 50 vent connection
- Plug
With thermal protection and test-push button
- PRIOX 300/9 AUT, PRIOX 460/13 M AUT submersible pump
188
VACUSYSTEM
TABLE OF HYDRAULIC PERFORMANCE
14
12
10
8
46
0/
13
6
30
4 0/9
Hm
L / 1' 100 200 300 400 500 600
Q 6 36
m3/ h 12 18 24 30
PUMP PERFORMANCE
Nominal Absorbed
power power L/1' 50 100 150 200 250 300 400
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW m /h 3 6 9 12 15 18 24
Discharge
N2141140 VS 200 - P 300 M 0,8 0,6 1,2 0,9 1 ~ 230 V 4,1 12,5 7,7 6,4 5 3,8 2,3 1
in meters
head
N2141150 VS 200 - P 460 M 1,4 1 2,2 1,6 1 ~ 230 V 7,2 20 11,8 10,8 9,8 8,5 7 5,5 2
VACUSYSTEM
VS 200 - P 300 M 500 380 250 100 185 250 130 410 350 800 410 350 635 515 720 185 85 27
VS 200 - P 460 M 500 380 250 100 185 250 130 410 350 800 410 350 635 515 720 185 85 29,2
189
VACUSYSTEM
COLLECTION AND PUMPING STATIONS FOR
DIRTY WATER
• CONNECTING FOOT
Electric pump motor
- Dry motor
- Level of protection IP68
- Class F insulation
- Single-phase power supply with
capacitor permanently activated and
thermal protection built into the motor
winding
- Completely insulated cable connection
chamber
- Self lubricating ball bearings
- Speed of rotation 2850 rpm
Usage limitations
- Type of liquid: water with suspended
solids of a maximum dimension
of 40 mm
- Maximum liquid temperature 40°C
- Minimum drainage level 60 mm
Design features
- The standard pumping station consists of:
- Tank
in polyethylene with a capacity of 175 l.
The closing lid is supplied with O-ring.
It warrants liquid seal and possible gas locks.
- DN 110 inlet, 2” outlet and DN 50 vent connection
- Connecting foot
- Plug
With thermal protection and test-push button
(single-phase pumps)
- Electric panel
for the control and protection of
three-phase electric pumps.
- Float switch
with 10 m of 3 x 1 H07 RN-F cable
(for three-phase pumps)
- PRIOX Submersible Pump
Models:
- Priox 300/9 M AUT, Priox 300/9 T
- Priox 460/13 M AUT, Priox 460/13 T
190
VACUSYSTEM
TABLE OF HYDRAULIC PERFORMANCE
14
12
10
8
46
0/
13
6
30
4 0/9
Hm
L / 1' 100 200 300 400 500 600
Q 6 36
m3/ h 12 18 24 30
PUMP PERFORMANCE
Nominal Absorbed
power power L/1' 50 100 150 200 250 300 400
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW m /h 3 6 9 12 15 18 24
N2141160 VS 200 S - P 300 M 0,8 0,6 1,2 0,9 1 ~ 230 V 4,1 12,5
7,7 6,4 5 3,8 2,3 1
Discharge
in meters
VACUSYSTEM
VS 200 S - P 300 M 500 380 250 100 185 250 130 410 350 800 410 350 635 515 720 185 85 37
VS 200 S - P 300 T 500 380 250 100 185 250 130 410 350 800 410 350 635 515 720 185 85 39
VS 200 S - P 460 M 500 380 250 100 185 250 130 410 350 800 410 350 635 515 720 185 85 38,8
VS 200 S - P 460 T 500 380 250 100 185 250 130 410 350 800 410 350 635 515 720 185 85 40,6
191
VACUSYSTEM
COLLECTION AND PUMPING STATIONS FOR
DIRTY WATER
• 2 SUBMERSIBLE PUMPS
• 2 CONNECTING FEET
• ELECTRIC PANEL FOR CONTROL AND PROTECTION
Motor
- Dry motor
- Level of protection IP68
- Class F insulation
- Single-phase power supply with
capacitor permanently activated and
thermal protection built into the
motor winding
- Completely insulated cable connection
chamber
- Speed of rotation 2850 rpm
- Self lubricating ball bearings
Usage limitations
- Type of liquid: water with suspended
solids of a maximum dimension of
40 mm
- Maximum liquid temperature 40°C
- Minimum drainage level 60 mm
Design features
- The standard pumping station consists of:
- Tank
In polyethylene with a capacity of 550 l.
The closing lid is supplied with O-ring.
It warrants liquid seal and possible gas locks.
- Two DN 110 inlet, two 2” outlet and DN 50 vent connection
- Two connecting feet
- Electric panel
for the control and protection of 2 single phase
or three phase electric pumps
- Two float switches
with 10 m of 3 x 1 H07 RN-F cable
- Pair of PRIOX Submersible Pumps
Models:
- Priox 300/9 M, Priox 300/9 T
- Priox 460/13 M, Priox 460/13 T
192
VACUSYSTEM
14
12
10
8
46
0/
13
6
30
4 0/9
Hm
L / 1' 100 200 300 400 500 600
Q 6 36
m3/ h 12 18 24 30
PUMP PERFORMANCE
Nominal Absorbed
power power L/1' 50 100 150 200 250 300 400
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW m /h 3 6 9 12 15 18 24
N2141200 VS 500 TWIN - P 300 M 0,8 0,6 1,2 0,9 1 ~ 230 V 4,1 12,5
7,7 6,4 5 3,8 2,3 1
Discharge
in meters
N2141210 VS 500 TWIN - P 300 T 0,8 0,6 1,2 0,9 3 ~ 400 V 1,55
head
VACUSYSTEM
VS 500 TWIN - P 300 M 650 600 695 850 915 500 80 815 415 1140 655 77,5 310 495 280 89,4
VS 500 TWIN - P 300 T 650 600 695 850 915 500 80 815 415 1140 655 77,5 310 495 280 89,4
VS 500 TWIN - P 460 M 650 600 695 850 915 500 80 815 415 1140 655 77,5 310 495 280 93,8
VS 500 TWIN - P 460 T 650 600 695 850 915 500 80 815 415 1140 655 77,5 310 495 280 93,8
193
PUMPS FOR SPECIAL APPLICATIONS
SWIMMEY
SELF-PRIMING PUMPS FOR SWIMMING POOLS
WITH PREFILTER
Motor
– Enclosed, externally ventilated
– Level of protection IP X5
with sealed parts
– Class F insulation
– Single phase power supply
with capacitor permanently activated
and thermal protection built into the
motor winding
– Three phase power supply with
external protection provided by
the user
– Self-lubricating ball bearings
– Speed of rotation 2850 rpm
– Suitable for continuous use
DESIGN FEATURES
Component Material
Pump body ABS
Prefilter ABS
Suction and delivery fittings ABS/PVC
Large bowl that may be Polyethylene HD
inspected via screw cap
Glass-fibre Reinforced lexan
Impeller (resistant to abrasion by sand)
Diffusor Glass-fibre Reinforced lexan
(resistant to abrasion by sand)
Mechanical seal Graphite
Counterface Ceramic
Shaft Stainless steel with insulating part
Support base Polypropilene
Screw filter cap Lexan with teflon-treated locking O ring
196
SWIMMEY
TABLE OF HYDRAULIC PERFORMANCE
24
20
16
19
12
15 33
28
12
8
24
4
Hm
L / 1' 50 100 150 200 250 300 350 400 450 500 550 600
Q
m3/ h 3 6 9 12 15 18 21 24 27 30 33 36
PUMP PERFORMANCE
Nominal Absorbed
Power Power L/1' 100 150 200 300 350 400 450 500
VOLTAGE
CODE MODEL (V) Amp. µF. Q
3
HP kW HP kW m /h 6 9 12 18 21 24 27 30
197
RainFLOW
BOOSTER SYSTEM FOR HARVESTED RAINWATER
The RainFLOW unit is an automatic pumping system designed for monitoring and controlling
the distribution of harvested rainwater. When insufficient rainwater is available from the
collecting tank (e.g. underground tank), the electronic control of RainFLOW switches to the
suction pipe of the main water integrated tank, by means of the built-in three-way valve.
In this way, RainFLOW ensures that water is always available at the points of consumption.
RainFLOW is supplied together with a self priming multistage centrifugal pump of the MAX
series.
Pump motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal Applications
protection built into the motor winding
- Speed of rotation 2850 rpm RainFLOW is suitable for the transfer and
- Suitable for continuous use pressurizing of water from rainwater
collection and utilization systems in single-
or two-family houses, farms and gardens,
as well as in small factories.
198
RainFLOW
TABLE OF HYDRAULIC PERFORMANCE
60
50
40
80/4
30 8
20
10
Hm
L / 1' 10 20 30 40 50 60 70 80
Q
m3/ h 0,6 1,2 1,8 2,4 3 3,6 4,2 4,8
PUMP PERFORMANCE
Nominal Absorbed
Power Power L/1' 0 20 40 60 80
CODE MODEL VOLTAGE Amp. µF. Q
(V) m /h
3
HP kW HP kW 0 1,2 2,4 3,6 4,8
Discharge
RainFLOW 0,75 0,55 1,1 0,8 1 ~ 230 V 4 12,5 45 36 28 17 1
N4501200 MAX 80/48 M
head
in meters
C
HI
H2
B
H3 M
D
A I P
E G
F L O
RainFLOW
199
BLAZE - BLAZEMASTER
SINGLE AND TWIN IMPELLER ENGINE DRIVEN PUMPS
The Onga engine driven pumps are particularly suitable where electrical power is not
readily available and when a large quantity of water and pressure is required.
• HONDA ENGINE
• HIGH EFFICIENCY AND PERFORMANCE
• HIGH FLOW RATE AND PRESSURE
• HIGH PRIMING CAPACITY
• ADAPTABILITY TO PIPE CONFIGURATIONS
Applications
- Fire Fighting
- Tank filling
- Water transfer
- Hydrants
- Irrigation
Usage limitations
- Maximum operating pressure: 13 bar
BY - Water temperature range: 5° C – 40° C
- Free clearance of solids:
3 mm (twin impellers)
5 mm (single impeller)
- Environment temperature:
Max. 40° C
MOTOR
BLAZE BLAZEMASTER
MOTOR - Air cooled 4 stroke OHV petrol engine,
25° inclined cylinder, horizontal shaft.
Cylinder type Cast iron cylinder
Bore stroke 68 x 45 mm 68 x 54 mm
Displacement 168 cm3 196 cm3
Max. power output 4,0 Kw (5,5 CV) / 3600 rpm 4,8 Kw (6,5 CV) / 3600 rpm
Starting system Recoil
Fuel tank capacity 3,6 lt
Specific fuel consumption 313 g/kWh - 230 g/CVh
Fuel type lead-free petrol
DESIGN FEATURES
Component Material
- Pump casing Aluminium
- Impeller Nylon
- Mechanical seal Ceramic
- Counterface Graphite
- Shaft Mild steel
- Diffusers Aluminium
- O’ring NBR
200
BLAZE - BLAZEMASTER
TABLE OF HYDRAULIC PERFORMANCE
120
105
90
75
60
45
B65
H
30 B55
BM H
BM 65
15 55 H
H
Hm
100 200 300 400 500 600 700 800
L / 1'
Q
m3/ h 6 12 18 24 30 36 42 48
PUMP PERFORMANCE
Power L/1' 0 50 100 200 300 400 500 600 700
CODE MODEL HONDA Q
MOTOR 3
m /h
HP kW 0 3 6 12 18 24 30 36 42
B65HEU BLAZE 6.5 HP 5/8in EU 6,5 4,8 GX 200 Discharge 65 62,5 60 52 45 37 28 20 9,8
head
BM55HEU BLAZEMASTER 5.5 HP 5/8in EU 5,5 4 GX 160 in meters 101 85 72 50 29 2
BLAZE - BLAZEMASTER
BLAZE 6.5 HP 5/8in EU 312 178 166 253 480 1” 1/2 1”- 1”- 1”1/2 - 1”1/2 23,2
BLAZEMASTER 5.5 HP 5/8in EU 312 178 178 253 480 2” 1”- 1”- 2”- 2” 22,9
BLAZEMASTER 6.5 HP 5/8in EU 312 178 166 253 480 2” 1”- 1”- 2”- 2” 23,9
201
P.G.A. - DELTA OIL
SPECIAL SELF-PRIMING LIQUID RING PUMPS FOR
DIESEL TRANSFER
The PGA series pumps are particularly suitable for diesel transfer.
Version equipped with power supply cable, switch and handle available.
PGA
Applications
DELTA OIL – Manufacture of delivery assemblies
– For farm diesel transfer
– Farm machines
– Small pumping stations
DESIGN FEATURES
Component Material
Pump casing EN GJL 200 (ex G20) Cast iron
Motor bracket EN GJL 200 (ex G20) Cast iron
Finned impeller Brass
Motor shaft X 12 CrNiS 1809 (AISI 416) Stainless steel
Mechanical seal Graphite
Counterface Ceramic
O’ring NBR 70 shore
202
P.G.A. - DELTA OIL
TABLE OF HYDRAULIC PERFORMANCE
50
40
30
P.G
P.
G
.A
.A
.4
.6
0
20 0-
-3
40
0
/D
EL
10
TA
OI
L
Hm
L / 1' 15 30 45 60 75
Q
m3/ h 0,9 1,8 2,7 3,6 4,5
PUMP PERFORMANCE
Nominal Absorbed
power power L/1' 5 10 15 25 35 45 60
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW m /h 0,3 0,6 0,9 1,5 2,1 2,7 3,6
N6232090 PGA 40 - 30 M 1 ~ 220 ÷ 240 V 2,7 8
0,6 0,45 0,75 0,55 28 23 18 13 5
N6232100 PGA 40 - 30 T 3 ~ 230 ÷ 400 V 1,6-0,9
Discharge
in meters
1 ~ 220 ÷ 240 V
head
N6232170 DELTA OIL 0,6 0,45 0,75 0,55 1 ~ 220 ÷ 240 V 2,7 8 28 23 18 13 5
ACCESSORIES
203
VERSAILLES
SUBMERSIBLE PUMPS FOR FOUNTAINS AND
WATER FEATURES
The VERSAILLES pumps have been designed for fountains, water features and waterfalls
in water gardens.
Applications
- For fountains, water features, waterfalls
in water gardens
Usage limitations
- Type of liquid: clear water, free of solids
- Maximum liquid temperature 40°C
- Maximum submersion under the water
level 7m
- Free clearance: 1,5mm.
For water features with a less
clearance insert the sponge filter
(optional) in the hydraulics
Motor
- Dry motor with stainless steel casing
- Level of protection IP68
- Class F insulation
- Single phase power supply with
capacitor permanently activated
- Thermal protection built into the motor
winding
- Completely insulated cable connection
chamber
- Self-lubricating ball bearings
- Speed of rotation 2850 rpm
- Suitable for continuous use
Accessories (optional)
- Vulcano: adjustable water feature
with three level jets
- Gaiser: adjustable water feature with
a single foamy jet
- Campana: adjustable bell-shaped
water feature
- Filters: sponge to be used for water
features with clearances
under 1.5 mm
SPARE FILTER
DESIGN FEATURES
Component Material
Suction grid X 5 CrNi 1810 (AISI 304) Stainless steel
Base X 5 CrNi 1810 (AISI 304) Stainless steel
Pump casing X 5 CrNi 1810 (AISI 304) Stainless steel
Impeller X 5 CrNi 1810 (AISI 304) Die cast stainless steel
Power cable 10 m H07 RN-F With plug
Fixed double NBR 70 rubber seal
Seal with special sand guard V-ring
Motor shaft X 12 CrS 13 (AISI 416) With
ceramic facing at the points of wear
1” F reducer Plastic
204
VERSAILLES
TABLE OF HYDRAULIC PERFORMANCE
12
10
8 350
/12
250
/10
6
16
0/8
4
Hm
L / 1' 50 100 150 200 250 300
Q
m3/ h 3 6 9 12 15 18
PUMP PERFORMANCE
Nominal Absorbed Diameter and height of water features
power power in cm
CODE MODEL VOLTAGE Amp. µF. Q l /1’
HP kW HP kW VULCANO GAISER CAMPANA
N2121010 VERSAILLES 160/8 0,5 0,37 0,6 0,45 1 ~ 220 ÷ 240 V 2,2 8 Ø 180 - H 360 Ø 20 - H 110 Ø 90 - H 45
Discharge
in meters
head
N2121020 VERSAILLES 250/10 0,75 0,55 1,2 0,9 1 ~ 220 ÷ 240 V 4,5 10 Ø 200 - H 420 Ø 30 - H 180 Ø 95 - H 45
N2121030 VERSAILLES 350/12 1,1 0,8 1,6 1,2 1 ~ 220 ÷ 240 V 5,1 16 Ø 200 - H 480 Ø 50 - H 230 Ø 100 - H 45
ZB401690 VULCANO
ZB401700 GAISER
ZB401710 CAMPANA
ZB401720 FILTER 1 FOR MOD. 80/7 - 160/8
VERSAILLES
205
VERSAILLES
VULCANO
GAISER
CAMPANA
206
Pressure assemblies
SIZING HOME WATER SYSTEMS
Fig. 1
17 200 500 50
20 100
30 80 300 60
43 60 ES
R
O
50 50
S ST 200 65
E T
57 40 C N
S
FI E
ON
M
E
PA O F
60 30 150 70
TI
T
R
TU
LS
TI
ES
E
100 75
TE
20
D
IS
M
63 18
O
H
16
14
66 12
10 80
5 6 7 8 9 10 12 14 16 18 20 30 40 60 80 100
m3/h
% CALCULATED CONTEMPORANEOUSNESS % CALCULATED CONTEMPORANEOUSNESS
207
Pressure assemblies
Fig. 2
CASE A
HE
H building 18 +
Minimum pressure 15 +
Flow resistance 2=
Deposit
Meters 35
HE = Building height 18 m.
Fig. 3
Deposit
CASE B
Head necessary 35 -
Mains water supply pressure 20 =
Meters 15
Pressure necessary 35 -
The tank 20 =
Public water Meters 15
supply system
pressure 2 ATM
HD =Deposit height 20 m.
Fig. 4
Min. pressure 1,5 ATM
CASE C
Head necessary 35 +
Suction height 5=
Meters 40
HA
HA = Suction height 5 m.
208
Pressure assemblies
FLOW RESISTANCE AND WATER SPEED TABLE
N.B. - To evaluate the flow resistance in pipes made of different materials, the value found for the galvanised
pipe must be multiplied by the following set coefficients:
0,6 for PVC pipes
0,7 for aluminium pipes
0,8 for rolled steel pipes
1,3 for cement fibre pipes
209
AUTOJET
BOOSTER SET WITH ELECTRONIC CONTROL
AND PROTECTION DEVICE
Advantages
- Start up pressure adjustable from
1 to 2,8 bar.
- Protection in case of lack of water
- Protection in case of excessive water
temperature
- Protection from an excessive number
of restartings per hour
- Limited dimensions
- Easy to install
Usage limitations
- Type of liquid: clean water with no
suspended solids or abrasive material
- Maximum liquid temperature 40° C
- Maximum recommended suction height:
Motor 8m with foot valve
- Maximum operating pressure: 6 bar
- Enclosed, externally ventilated
- Level of protection: IP44
- Class F insulation
- Single phase power supply with
capacitor permanently activated
- Thermal protection built into the motor
winding
- Speed of rotation 2850 rpm
- Suitable for continuous use
Design features
- Aqua-Matic:
Start up pressure adjustable from
Applications 1 to 2,8 bar.
Max flow rate 6m3/h
- Pumping and distribution of water in Min/max fluid temperature:
domestic systems from 4° to 40° C
- Booster systems - Power supply cable: 1,5 m H05 RN-F
- Washing systems, irrigation with plug
DESIGN FEATURES
Component Material
1 Pump casing X5 CrNi 1810 (AISI 304) Stainless steel
2 Motor bracket Die cast aluminium
3 Impeller Technopolymer with stainless steel
shim ring
4 Diffusor - venturi Technopolymer
tube and nozzle
5 Shaft X 12 CrNiS 1809 ( AISI 416 ) Stainless steel
6 Mechanical seal Graphite
7 Counterface Ceramic
Technopolymer (series 45-60-70)
8 Seal holder plate X5 CrNi 1810 ( AISI 304 ) stainless steel serie 90
9 O’ring NBR 70 Shore
210
AUTOJET
TABLE OF HYDRAULIC PERFORMANCE
60
50
40
30
70
/5
60 0
20 /5
0
10
Hm
L / 1' 20 40 60 80
Q
m3/ h 1,2 2,4 3,6 4,8
PUMP PERFORMANCE
Nominal Absorbed
power power L/1' 0 10 20 30 40 50 60
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW (V) m /h 0,0 0,6 1,2 1,8 2,4 3,0 3,6
N4176880 AUTOJET 60/50 0,75 0,55 1,10 0,8 1 ~ 230 V 4 12,5 Discharge 46 36 31 26 18 6
head
N4176870 AUTOJET 70/50 0,95 0,7 1,36 1,0 1 ~ 230 V 4,5 16 in meters 48 42,5 37,5 32 25 16,5 7
DNM
DNA
B
D
E
A
AUTOJET
211
AUTOMAX
BOOSTER SET WITH ELECTRONIC CONTROL
AND PROTECTION DEVICE
Advantages
- Start up pressure adjustable from
1 to 2,8 bar.
- Protection in case of lack of water
- Protection in case of excessive water
temperature
- Protection from an excessive number
of restartings per hour
- Limited dimensions
- Easy to install
Usage limitations
- Type of liquid: clean water with no
suspended solids or abrasive material
- Maximum liquid temperature 40° C
- Maximum recommended suction height:
Motor 7m with foot valve
- Maximum operating pressure: 6 bar
- Enclosed, externally ventilated
- Level of protection: IP44
- Class F insulation
- Single phase power supply with
capacitor permanently activated
- Thermal protection built into the motor
winding
- Speed of rotation 2850 rpm
- Suitable for continuous use Design features
- Aqua-Matic:
Start up pressure adjustable:
Applications from 1 to 2,8 bar.
Max flow rate 6m3/h
- Pumping and distribution of water Min/max fluid temperature:
in domestic systems from 4° to 40° C
- Booster systems - Power supply cable: 1,5 m H05 RN-F
- Washing systems, irrigation with plug
9 10 DESIGN FEATURES
Component Material
1 Pump casing X5 CrNi 1810 ( AISI 304 ) Stainless steel
2 Motor bracket Die cast aluminium
4 Diffusor - venturi
tube and nozzle Technopolymer
212
AUTOMAX
TABLE OF HYDRAULIC PERFORMANCE
60
50
120
/60
40
30
80
/48
20
10
Hm
L / 1' 20 40 60 80 100 120
Q
m3/ h 1,2 2,4 3,6 4,8 6 7,2
PUMP PERFORMANCE
Nominal Absorbed
power power L/1' 0 20 40 60 80
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW (V) m /h 0,0 1,2 2,4 3,6 4,8
N4501170-B AUTOMAX 80/48 0,75 0,55 1,1 0,8 1 ~ 230 V 4 12,5 45 36 28 17 1
N4501180-B AUTOMAX 120/60 1,2 0,9 1,7 1,25 1 ~ 230 V 5,8 20 60 55 48 36 26
DNM
DNA
E
D
A
C
B F
AUTOMAX
213
WATERPRESS
BOOSTER SETS WITH 24L HORIZONTAL
EXPANSION TANK
The WATERPRESS booster sets are made up of JET self-priming centrifugal pumps.
They are supplied wired, tested and complete with 24l expansion tank. Ready to use.
Applications
- Pumping and distribution of water in
domestic systems
- Booster systems
- Washing systems and irrigation
Usage limitations
- Type of liquid: clean water with no
suspended solids or abrasive material
- Maximum liquid temperature 50° C
- Maximum suction height 8m with foot
valve
- Maximum operating pressure 6 bar
Design features
Component Material
WATERPRESS 40/40 - 60/50 WATERPRESS 70/50
Pump casing EN GJL 200 ( ex G20 ) Cast iron EN GJL 200 ( ex G20 )Cast iron
Motor bracket Aluminium EN GJL 200 ( ex G20 )Cast iron
Technopolymer with
Impeller X5 CrNi 1810 ( Aisi 304 ) Technopolymer
stainless steel shim ring
214
WATERPRESS
TABLE OF HYDRAULIC PERFORMANCE
50
40
30
20
10
Hm
L / 1' 10 20 30 40 50 60 70 80
Q
m3/ h 0,6 1,2 1,8 2,4 3 3,6 4,2 4,8
PUMP PERFORMANCE
Nominal Absorbed
power power L/1' 0 10 20 30 40 50 60 70
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW m /h 0 0,3 1,2 1,8 2,4 3 3,6 4,2
Discharge
N5209160 WATERPRESS 60/50 0,75 0,55 1,1 0,8 1 ~ 220 ÷ 240 V 4 10 head 46 36 31 24 9 4
in meters
WATERPRESS
215
WATERPRESS INOX
BOOSTER SET WITH 24 Lt
HORIZONTAL EXPANSION TANK
The WATERPRESS INOX booster sets are produced with JETINOX or MAX pumps.
They are supplied wired, complete with 24 lt expansion tank, ready to use.
Motor Applications
– Enclosed, externally ventilated - Pumping and distribution of water
– Level of protection: IP44 in domestic systems
– Class insulation: F - Booster systems
– Single phase power supply with - Washing systems and irrigation
capacitor permanently activated.
– Thermal protection built into the
motor winding Usage limitations
– Speed of rotation: 2850 rpm.
– Suitable for continuous use. – Type of liquid: clean water with
no suspended solids or abrasive
materials
Design features – Maximum liquid temperature: 50°C
– Maximum suction height 8 m with foot
– Pressure switch (max 6 bar) calibrated valve (7m for WATERPRESS INOX
at: min 2 ÷ max 3 bar 80/48)
– Pressure gauge (6 bar) – Maximum operating pressure: 6 bar
– Chromium plated pressed brass 5 way
fitting
– 24Lt painted steel expansion tank with
interchangeable food quality rubber
diaphragm.
– Flexible pipe for water connection
– 1,5 m H05 RN-F power supply cable
with plug
216
WATERPRESS INOX
TABLE OF HYDRAULIC PERFORMANCE
60
50
40
30
70
20 /50
10
Hm
L / 1' 10 20 30 40 50 60 70 80
Q
m/ h
3
0,6 1,2 1,8 2,4 3 3,6 4,2 4,8
PUMP PERFORMANCE
Nominal Absorbed
power power L/1' 0 20 40 60 80
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW m /h 0 1,2 2,4 3,6 4,8
N5209750 WP INOX 70/50 0,95 0,7 1,36 1,0 1 ~ 230 V 4,5 16 Discharge 48 37,5 25 7
head
N5301110 WP INOX 80/48 0,75 0,55 1,1 0,8 1 ~ 230 V 4 12,5 in meters 45 36 28 17 1
WATERPRESS INOX
WATERPRESS INOX 70/50 520 445 565 260 1" F 1" F 13,8
WATERPRESS INOX 80/48 520 430 550 260 1" F 1" F 12,3
217
WATERPRESS INOX 50 L
BOOSTER SET WITH 50 Lt HORIZONTAL
EXPANSION TANK
The WATERPRESS INOX 50 L is a booster set produced with MAX self-priming multistage
centrifugal pump. It is supplied wired, complete with 50 Lt expansion tank, ready to
use.
WP INOX 80/48 -
50 Lt with AQUA TROL
electronic pressure switch
Applications
WP INOX 80/48 - - Pumping and distribution of water
50 Lt with electromechanical in domestic systems
pressure switch - Booster systems
- Washing systems and irrigation
Design features
WP INOX 80/48 - 50 L: electromechanical pressure switch (max 6 bar) set at min
2 ÷ max 3 bar
WP INOX 120/60 - 50 L: electronic control and protection pressure switch
AQUA TROL.
Adjustable pump's starting pressure: from 1,5 to 3 bar.
DESIGN FEATURES
Component Material
Pump casing X 5 CrNi 1810 (AISI 304) Stainless steel
Motor bracket Die cast aluminium
Impellers Technopolymer
with stainless steel shim ring
Diffuser Technopolymer
Shaft (hydraulic end) X 5 CrNi 1810 (AISI 304) Stainless steel
Mechanical seal Graphite
Counterface Ceramic
Seal plate Technopolymer
O'ring NBR 70 Shore
218
WATERPRESS INOX 50 L
TABLE OF HYDRAULIC PERFORMANCE
60
50
40
30
80
/4
8
20
10
Hm
L / 1' 20 40 60 80 100 120
Q
m3/ h 1,2 2,4 3,6 4,8 6 7,2
PUMP PERFORMANCE
Nominal Absorbed
power power L/1' 0 20 40 60 80
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW m /h 0 1,2 2,4 3,6 4,8
N5301140 WP INOX 80/48 0,75 0,55 1,1 0,8 1 ~ 230 V 4 12,5 Discharge 45 36 28 17 1
head
N5301130 WP INOX 120 /60 1,2 0,9 1,7 1,25 1 ~ 230 ÷ 240 V 5,8 20 in
20meters 60 55 48 36 26
WATERPRESS INOX 50 L
219
WATERPRESS SUPERINOX
BOOSTER SET WITH 24 Lt HORIZONTAL
EXPANSION TANK
The WATERPRESS SUPERINOX is a booster set produced with JETINOX or MAX self
priming centrifugal pump. It is supplied wired and complete with stainless steel expansion
tank.
220
WATERPRESS SUPERINOX
TABLE OF HYDRAULIC PERFORMANCE
60
50
12
0/6
40 0
30
20
10
Hm
L / 1' 20 40 60 80 100 120
Q
m3/ h 1,2 2,4 3,6 4,8 6 7,2
PUMP PERFORMANCE
Nominal Absorbed
power power L/1' 0 20 40 50 60 80
CODE MODEL VOLTAGE Amp. µF. Q
3
HP kW HP kW m /h 0 1,2 2,4 3 3,6 4,8
N5209680 WP SUPERINOX 60/50 C 0,75 0,55 1,1 0,8 1 ~ 220 ÷ 240 V 4 12,5 Discharge 46 31 18 6
head
WATERPRESS SUPERINOX
in meters
N5301150 WP SUPERINOX 120/60 C 1,2 0,9 1,7 1,25 1 ~ 220 ÷ 240 V 5,8 20 60 55 48 44 36 26
221
PRESSOMAT RESIDENTIAL USE
PRESSURE BOOSTER UNITS CONTROLLED BY PRESSURE
SWITCH
Pressure booster units equipped with single and three phase pumps for the automatic
pressurization of water supply systems.
Operation
The pumps are controlled by two differential pressure switches with adjustable calibration
due to the electric control panel supplied with SM electronic card for:
– Sequential starting of the pumps
– Changeover of starting order
– Protection against dry running
– Adjustable timing from 0 to 180 seconds (three phase version)
When the system pressure reaches the closing value of the electric contact of
pressure switch n°1, the first pump starts. If the water consumption increases and the
pressure goes down the second pump starts. When pressure increases the manostats
open their contact switching off one of the pumps.
At the end of each cycle, the automatic inverter changes the starting order of the
pumps (at the first cycle pressure switch n° 1 is associated to pump n°1; the next
cycle to pump n°2). In case of simultaneous closing of the two pressure switches, the
electronic card delays the starting of the second pump avoiding strong pressure jolts
and overload of the electric power supply.
Applications Basement
- Pumping of water in domestic - Galvanized iron
systems
- Booster systems
- Washing systems and irrigation
222
PRESSOMAT
THREE PHASE ELECTRIC PANEL
Electric panel
- IP54 metallic case
- General switch
- Keyboard with SA electronic card
- Fuses, manifold and thermal relay for each pump
- Transformer with fuses for the auxiliary circuit
- M-A selector for each pump
Main functions
- Cyclic inversion of the starting order of the pumps after the end of every operation cycle
- ON/OFF control of the level of the first gathering tank or of the pressure in the feeding pipe through a float
switch or an inverse differential manostat.
- Timing, adjustable from 0 to 180 seconds of the pumps operation after the manostat’s contact opens.
223
PRESSOMAT
SINGLE PHASE ELECTRIC PANEL
Electric panel
- IP55 metallic case
- Magnetic-thermal main breaker
- Fuses, manifold and thermal relay for each pump
- Transformer with fuses for the auxiliary circuit
- SML electronic card
- Pump starting relay
Main functions
- Cyclic inversion of the starting order of the pumps after the end of every operation cycle
- ON/OFF control of the level of the first gathering tank or of the pressure in the feeding pipe through a float
switch or an inverse differential manostat.
224
PM.20/VA - MULTINOX
TABLE OF HYDRAULIC PERFORMANCE
70
60
PM
.20/
VA-
M ULT
INO
50 PM.2 X 12
0/60
0/VA
-MU PM
LTIN
O X 12 .2
0/48 0/VA
40 - MU
PM LT
.20 IN
/VA OX
-M 80
ULT /60
30 PM. INO
X8
20/V 0/4
A-M 8
ULT
INO
X 80
/36
20
10
Hm
L / 1' 40 80 120 160 200 240
Q
m3/ h 2,4 4,8 7,2 9,6 12 14,4
PUMP PERFORMANCE
L / 1’ 0 40 80 120 160 200
TYPE KW
m3 / h 0 2,4 4,8 7,2 9,6 12
PM.20/VA-MULTINOX 80/36 2x0,45 33 28 22 15 7
Discharge head
D2
PM.20/VA - MULTINOX
H3
H2
D1
H1
L2
L1 P1
225
PM.20/VA - MULTINOX-A
TABLE OF HYDRAULIC PERFORMANCE
90
80
70 PM
.20/
VA-
M ULT
INO
60 PM. X-A
20/V 200
A-M /80
ULT
INO
50 X-A
PM.2 200/
0/VA 65
-MUL
TINO
40 X-A 2
PM.2 00/52
0/VA-
MULT
INOX
30 -A 20
0/40
20
10
Hm
L / 1' 40 80 120 160 200 240 280 320 360
Q
m3/ h 2,4 4,8 7,2 9,6 12 14,4 16,8 19,2 21,6
PUMP PERFORMANCE
L / 1’ 0 40 80 160 240 320
TYPE KW
m3 /h 0 2,4 4,8 9,6 14,4 19,2
Discharge head
D2
H3
H2
D1
H1
L2
L1 P1
226
PM.20/VA - MULTINOX-VE
TABLE OF HYDRAULIC PERFORMANCE
120
100 PM
.20/
VA-
M ULT
INO
X-V
E 20
80 PM.2
0/11
0
0/VA
-MU
PM.2 LTIN
0/VA X-VE O
-MU 200/
LTIN 90
60 PM.20 OX-V
E 20
/VA-M 0
ULTIN /80
OX-V
PM.20 E 200
/VA-M / 6 5
ULTINO
40 X-VE 2
PM.20/V 00/52
A-MULT
INOX-VE
200/40
20
Hm
L / 1' 50 100 150 200 250 300 350 400
Q
m3/ h 3 6 9 12 15 18 21 24
PUMP PERFORMANCE
L / 1’ 0 40 80 160 240 360
TYPE KW
m3 /h 0 2,4 4,8 9,6 14,4 21,6
PM.20/VA-MULTINOX-VE 200/40 2x1,1 40 38 37 32 24 12
Discharge head
DNM
H3
DNA H2
H1
L2
P1 L1
227
WELLMATE TANKS
IN COMPOSITE MATERIAL
Wellmate tanks in composite material represent the best solution for pressurized water storage and pressureboosting
applications. Thanks to the high density polyethylene inner liner and to the fiberglass-wound and epoxy resin-sealed outer
shell, Wellmate tanks don't rust,require little maintenance and weigh half then an equivalent steel tank. All Wellmate vessels
are tested and certified by NSF International and produced according to the European Pressure Equipment Directive (PED)
97/23/EC.
TECHNICAL FEATURES
REAL WATER MAXIMUM
CODE VOLUME OPERATING CONNECTIONS
VOLUME
lt (DRAWDOWN SETTING)* PRESSURE (BAR)
WM0060 55 18,3 8,5 1” M NPT
WM0075 75 25 8,5 1” M NPT
WM0120 112 37,3 8,5 1” M NPT
WM0150 153 50,9 8,5 1” M NPT
WM0180 178 59,3 8,5 1”1/4 M NPT
WM0235 235 78,3 8,5 1”1/4 M NPT
WM0330 328 109,2 8,5 1”1/4 M NPT
WM0450 453 150,8 8,5 1”1/4 M NPT
WM0600 606 201,8 10 2” M BSP
WM0750 757 252,1 10 2” M BSP
WM1000 1022 340,3 10 2” M BSP
Note: Maximum external operating temperature 120°F (49°C). Maximum internal operating temperature 100°F (38°C). Minimum operating temperature 40°F (4°C).
* With minimum and maximum system pressure between 2,0 and 3,5 bar
228
EXPANSION TANKS
STAINLESS STEEL
NOCCHI expansion tanks are made of AISI 304 stainless steel and are available in several models that are able to meet all the
demand of civil and industrial plants.
No toxic replaceable bladder suitable for food use, particularly recommended for use in humid environments.
In compliance with EC standards.
UPRIGHT VERSION
Interchangeable bromobutyl diaphragm,
and capacities of 8-20-24 litres.
The latter version is also available without
diaphragm with an air feeder.
Preload: 1,5 bar
HORIZONTAL VERSION
24- litres diaphragm with assembly
bracket for the electric pump and a new
support foot, designed to ensure
maximum stability.
Preload: 1,5 bar
PERFORMANCE
ØB
ØB
A
A
ØB
C
D
A
D D
229
EXPANSION TANKS
PAINTED STEEL
Expansion tank for pressure assemblies, in painted steel, from 2 to 500 Lt.,
with interchangeable diaphragm.
Stainless steel painted carbon flange. CE certificate.
Preload: 1.5 bar for models from 2 to 24 Lt.
2.0 bar for models from 60 to 500 Lt.
In compliance with EC standards
ØB
ØB
A
A
ØB
C
D
A
D
PUMP PERFORMANCE
Max. operating Capacity
CODE MODEL DESCRIPTION DIAPHGRAM Assembly pressure Lt
bracket ( bar )
ZA003860 VES 2 2 LITER EXPANSION TANK Food - quality rubber - 6 2
ZA000140 VES 24 V VERTICAL 24 LITER EXPANSION TANK Food - quality rubber - 6 24
ZA003850 VES 24 H HORIZONTAL 24 LITER EXPANSION TANK Food - quality rubber YES 6 24
ZA009120-CE VEC 60 H HORIZONTAL 60 LITER EXPANSION TANK Butyl rubber YES 10 60
ZA009070-CE VEC 60 V VERTICAL 60 LITER EXPANSION TANK Butyl rubber YES 10 60
ZA009130-CE VEC 100 H HORIZONTAL 100 LITER EXPANSION TANK Butyl rubber YES 10 100
ZA009080-CE VEC 100 V VERTICAL 100 LITER EXPANSION TANK Butyl rubber YES 10 100
ZA009090-CE VEC 200 V VERTICAL 200 LITER EXPANSION TANK Butyl rubber YES 10 200
ZA009100-CE VEC 300 V VERTICAL 300 LITER EXPANSION TANK Butyl rubber YES 10 300
ZA009110-CE VEC 500 V VERTICAL 500 LITER EXPANSION TANK Butyl rubber YES 10 500
Dimensioni mm. Kg
Modello
A ØB C D
VES 2 175 155 - 1” M 0,950
VES 24 V 415 295 - 1” M 4,1
VES 24 H 415 - 310 1” M 4,8
VEC 60 H 680 - 382 1” M 17
VEC 60 V 845 382 - 1” M 17,5
VEC 100 H 780 - 450 1” M 18
VEC 100 V 950 450 - 1” M 19
230
ELECTRONIC CONTROL AND PROTECTION DEVICES
231
VSD
VARIABLE SPEED DRIVE
VSD is able to modify the electropump frequency in order to grant the requested
delivery maintaining a constant pressure.The setting is possible thanks to a pressure
sensor and a flow sensor connected to the inverter. The constant pressure grants
a considerable energy saving and excellent performances. VSD range is available
in three versions:
- VSD1 Basic (max 4.5 Amp.)
- VSD1 (max 9.3 Amp.)
- VSD3 (max 13.3 Amp.)
• EASY TO INSTALL
Protection Devices
– Dry running
– Amperometric
– Overcurrent
– Overtemperature of the electronics
Applications
– Irrigation
– Industry
– Hotel installations
– Buildings- Washing systems
232
VSD
VARIABLE SPEED DRIVE
VSD1 basic and VSD1 are 1X230V single phase devices, able to modulate the speed of a three-phase pump (3X230V)
keeping constant pressure in the system. VSD3 is a 3X400V three-phases device able to modulate the speed of a
three-phase pump (3X400V). 2 set points system (on VSD1 and VSD3).
WORKING POSITIONS
Whole range VSD1 Basic / VSD1
TECHNICAL FEATURES
Max Power Electropump Liquid Max operating pressure
Pressure regulation
DNA DNM range
Protection Set Optional contacts
Digital Connections
motor supply voltage temp. Bar Bar level point inputs
MODEL current voltage V
Amp. V
174 L
1”1/2 F P
1”1/4 F
233
VSD - PUMP SELECTION TABLE
PUMP SELECTION TABLE
VLR2B 30/2 to VLR2B - 110 VLR2B 30/2 to VLR2B - 220 VLR2B 30/2 to VLR2B – 260
MCX 200/40
SA SA 615/4 to SA 615/6
234
FLUSSCONTROL
ELECTRONIC CONTROL AND PROTECTION DEVICE FOR ELECTRIC
SINGLE PHASE PUMPS
Applications
Start up and stop of single-phase surface
or submersible pumps. Flusscontrol
maintains constant pressure during
delivery and it starts and stops the pump
in accordance with the opening and
closing of the taps.
Functioning
FLUSSCONTROL controls the start-up
and the stop of the pump. If no water is
supplied, the electronic system stops the
pump to protect it from dry running. After
eliminating the causes of the stopping it
is sufficient to press the red Restart button
to restore normal operation.
In case of a temporary electricity cut-off
the device will automatically start up again
when the power returns.
Advantages
- Attenuates the effects of water
hammering
- Replaces the traditional expansion tank
system
- Maintenance-free
- Protection from dry running
- Easy to install
- Maintains constant pressure during
delivery
Technical features
- Power supply 230 V single phase
- Max. current 16 (8) A
- Max. absorbed power of the pump 1,5 kW (2 HP)
- Frequency 50-60 Hz
- Protection level IP 65
- Friction loss with a flow rate of 6 m3/h 0,95 bar
- Max. pressure 10 bar
- Max. operating temperature 65° C
- Weight 1,07 Kg
CODE MODEL
ZB401960 FLUSSCONTROL
235
FLUSSCONTROL BASIC
ELECTRONIC CONTROL AND PROTECTION DEVICE FOR ELECTRIC
SINGLE PHASE PUMPS
Applications
Control and protection of single-phase
surface or submersible pumps for
domestic water supply system, gardening
and irrigation in general.
It is directly installed on the delivery of
the pump or between the delivery and the
first user, managing the operation of the
pump.
Functioning
FLUSSCONTROL BASIC controls the
start-up and the stop of the pump. If no
water is supplied, the electronic system
stops the pump to protect it from dry
running. After eliminating the causes of
the stopping it is sufficient to press the
red Restart button to restore normal
operation.
In case of a temporary electricity cut-off
the device will automatically start up again
when the power returns.
Advantages
- Attenuates the effects of water
hammering
- Replaces the traditional expansion tank
system
- Maintenance-free
- Protection from dry running
- Easy to install
- Maintains constant pressure during
delivery
Technical features
- Power supply 230 V single phase
- Max. current 16 (6) A
- Max. absorbed power of the pump 1,1 kW
- Frequency 50-60 Hz
- Protection level IP 65
- Friction loss 1.1 bar
- Max. pressure 8 bar
- Max. operating temperature 40° C
- Weight 0.8 Kg
CODE MODEL
236
AQUA MATIC
ELECTRONIC CONTROL AND PROTECTION DEVICE FOR
ELECTRIC SINGLE-PHASE PUMPS
Applications
Control and protection of single-phase
surface or submersible pumps for
domestic water supply system, gardening
and irrigation in general.
It is directly installed on the delivery of
the pump or between the delivery and the
first user, and is used to control the
pressure with which the water is supplied
to the user’s system by automatically
managing the operation of the pump.
Functioning
AQUA MATIC controls the start-up and
the stop of the pump.
If no water is supplied, the electronic
system stops the pump, protecting it from
running in dry conditions.
If the temperature exceeds the maximum
limits set, for AQUA MATIC a sensor inside
the device stops the pump.
In case of water leakage, a timer regulates
the pump functioning time and protect it
from an excessive number of restartings
per hour.
It works without the expansion tank.
Advantages
- Start up pressure adjustable from
1 to 2.8 Bar
- Protection in case of excessive water
temperature
- Protection from an excessive number
of restartings per hour.
- Limited dimensions
- Easy to install (version with 1.5 Mt.
H07 RNF power cable)
Technical features
- Power supply 230V single phase
- Max. intensity 10 A
- Max. absorbed power of the pump 1,5 Kw
- Frequency 50-60 HZ
- Protection class IP 54
- Max. flow rate 6 m3/h
- Max. pressure 10 BAR
- Min./Max. temperature of the fluid da 4 a 40˚C
- Weight 1,3 KG
CODE MODEL
237
AQUA TROL
ELECTRONIC CONTROL AND PROTECTION PRESSURE SWITCH FOR ELECTRIC
SINGLE-PHASE PUMPS
Applications
Control and protection of single-phase
surface electro pumps with supply vessel
for domestic water supply system,
gardening and irrigation in general.
Functioning
AQUA TROL controls the start-up and the
stop of the pumps when water is
requested (when the tab is turned
on or off)
AQUA TROL protects the pump from
running in dry conditions: if the
temperature of the water flow exceeds
the maximum limit set, a sensor inside
the AQUA TROL prevents the electro
pump from starting, signalling the anomaly
on the front panel.
In the event that pressure falls within the
supply vessel, a timer controls the
operation of the pump, protecting it from
being started too frequently within the
same hour.
It can be installed with membrane tanks
of 24, 60, 100, 200, 300 and 500 Lt.
Advantages
- Start up pressure adjustable from
1.5 to 3 Bar
- Protection in case of excessive water
temperature
- Protection from an excessive number
of restartings per hour.
- Limited dimensions
- Easy to install (version with 1.5 Mt.
H07 RNF power cable)
- It replaces the traditional pressure
switch.
Technical features
- Power supply 230V mono
- Max. intensity 10 A
- Max. absorbed power of the pump 1,5 Kw
- Frequency 50-60 HZ
- Protection class IP 54
- Max. pressure 10 BAR
- Max. temperature of the fluid 60˚C
- Weight 0,75 Kg
CODE MODEL
238
CONTROL PANELS
QES PLUS
SINGLE PHASE STARTER FOR THE CONTROL AND PROTECTION OF SUBMERGED
ELECTRIC PUMPS, DIRECT START
Main components
- IP55 plastic box
- Main switch with circuit breaker
and motor
- Protector with restart button
- Capacitor.
- Terminal board
- Cable gland
Technical features
- Protection level : IP55
- Power supply voltage : 230V/ 1F 50 Hz
- External dimensions : 115 - 185 - 65 mm
- Weight : Kg 0,6
Type of functioning
- Manual through general switch
- Automatic through external remote
control (manostat, float…)
Connection plan
Limits in use
- Environmental temperature : -5 / +40 °C
- Relative humidity : 50% at 40°C
(without forming of condense)
- Standards : EN 60335-1 - EN 60439-1
Optional accessories
- Float switch or pressure switch (see accessories table)
CONTROL PANELS
241
QEC+S/QEM+S
SINGLE PHASE STARTERS FOR THE CONTROL AND PROTECTION OF SUBMERGED
OR SURFACE PUMPS, DIRECT START
Main components
- IP 45 plastic box.
- ON – OFF switch
- TEST button
- Motor protector with restart button
- Power led
- Function light
- Terminal board
- Cable gland
- Capacitor (QEC+S)
Technical features
- Protection level : IP45 Connection plan
- Power supply voltage : 230V/ 1F 50 Hz
- External dimensions : 205 - 150 – 75 mm QEC+S
- Weight : Kg 0,8 - 1
Type of functioning
- Manual through general switch
- Automatic through external remote
control (Manostat, float…)
QEM+S
Limits in use
- Environmental temperature : -5 / +40 °C
- Relative humidity : 50% at 40°C
(without forming of condense)
- Standards : EN 60439-1
Optional accessories
- UZA00100 - ECL electrodes for level control
- Float switch or pressure switch (see accessories table)
242
QET+S
THREE PHASE STARTER FOR THE CONTROL OF SUBMERGED OR SURFACE
ELECTRIC PUMPS, DIRECT START
Main components
- IP 45 IP 45 plastic box.
- ON – OFF switch
- TEST button
- Contactor thermal relay
- Power led
- Function led
- Thermal block light with restart button
- Terminal board
- Cable gland
Technical features
- Protection level : IP45
- Power supply voltage : 400V/ 3F 50 Hz
- External dimensions : 205 - 150 – 75 mm
- Weight : Kg 1
Type of functioning
- Manual through general switch
- Automatic through external remote
control (manostat or float…)
Connection plan
Limits in use
- Environmental temp. : -5 / +40 °C
- Relative humidity : 50% at 40°C
(without forming of condense)
- Standards : EN 60439-1
Optional accessories
- UZA00100 - ECL electrodes for level control
- Float switch or pressure switch (see accessories table)
CONTROL PANELS
243
AD
THREE PHASE STARTER FOR THE CONTROL OF SUBMERGED OR SURFACE
ELECTRIC PUMPS, DIRECT START
Main components
- IP 54 painted metallic case.
- Main switch, door block
- Fuse block with fuses on the
main circuit
- Fuse block with fuses on the
auxiliary circuit
- Ammeter with amperometric
transformer
- Voltmeter with voltmetric selector
- Level block light
- Function light
- Power led
- Thermal block light
- Terminal board
- Contactor 24 V
- Overload protection and phase
absence thermal relay
- Level control module
- Transformer for auxiliary circuit
- Cable gland
- MAN -or -AUT Selector
Technical features
- Protection level : IP54
- Power supply voltage : 400V/ 3F 50 Hz
- External dimensions : 320 - 400 - 180 mm
- Weight : Kg 14-50
Connection plan
Type of functioning
- Manual through Man. or Aut. Selector
- Automatic through external remote
control (manostat, float, …) and/or
level control (filling, emptying, dry
function protection)
Limits in use
- Environmental temp. : -5 / +40 °C
- Relative humidity : 50% at 40°C
(without forming of condense)
- Standards : EN 60730 - EN 60439
Optional accessories
- UZA00100 ECL electrodes for level control
- CE040010 Panel wall mount fixing fins
- Float switch or pressure switch (see accessories table)
244
AY/AR
THREE PHASE STARTERS FOR THE CONTROL OF SUBMERGED OR SURFACE
ELECTRIC PUMPS
Type of functioning AR
Limits in use
- Environmental temp. : -5 / +40 °C AY
- Relative humidity : 50% at 40°C
(without forming of condense)
- Standards : EN 60730 - EN 60439
Optional accessories
- UZA00100 - ECL electrodes for level control
- CE040020 - Panel wall mount fixing fins
- Float switch or pressure switch (see accessories table)
245
ADRM
SINGLE PHASE STARTERS FOR THE CONTROL OF ONE OR TWO DRAINING AND
SEWAGE ELECTRIC PUMPS
Main components
- IP 54 metallic case
- General switch
- Fuse block with fuses for the
electric pump
- Contactor with thermal relay
- Transformer for auxiliary circuit
- Fuse block with fuses on the
auxiliary circuit
- Terminal board with level control
devices
- Cable gland
- Function light
- Power led ADRM10
- Thermal block light
ADRM 10 ADRM 20
- Electronic signalling, control - Electronic signalling, control
and command card and command card equipped
- For the control of one electric pump with cyclic startings converter
- Weight : Kg 5,5 - For the control of two electric pumps
- Weight : Kg 7,5
ADRM20
Technical features
- Protection level : IP54
- Power supply voltage : 220V/240V 1F 50 Hz Connection plan
- External dimensions : 220 x 270 x 185 mm
ADRM10
Type of functioning
- Manual through general switch.
- Automatic through float switch.
Limits in use
- Environmental temperature : -5 / +40 °C ADRM20
- Relative humidity : 50% at 40°C
(without forming of condense)
- Standards : EN 60730 - EN 60439
Optional accessories
- CE040030 - Panel wall mount fixing fins
- UZA00200 - Optical, acoustic alarm
- Float switches (see accessories table)
246
ADRD
THREE PHASE STARTERS FOR THE CONTROL OF ONE OR TWO DRAINING AND
SEWAGE ELECTRIC PUMPS
Technical features
- Protection level : IP54
- Power supply voltage : 400V 3F 50 Hz
- External dimensions : 220 x 270 x 185 mm
- Weight : Kg 5,5
Connection plan
ADRD10
Type of functioning
- Manual through general switch
- Automatic through float switch
Limits in use
- Environmental Temperature : -5 / +40 °C
- Relative humidity : 50% at 40°C
(without forming of condense) ADRD20
- Standards: EN 60730 - EN 60439
Optional accessories
- CE040030 - Wall mount fixing fins
- UZA00200 - Optical, acoustic alarm
- Float switches (see accessories table)
247
ADRY
THREE PHASE STARTERS FOR THE CONTROL OF ONE OR TWO DRAINING AND
SEWAGE ELECTRIC PUMPS, STAR-TRIANGLE START
Main components
- IP 54 metallic case
- General switch
- Fuse block with fuses for the electric pump
- Contactor with thermal relay
- Transformer for auxiliary circuit
- Fuse block with fuses on the auxiliary circuit
- Electronic signalling, control and command
- card equipped with:
- Function light
- Power led
- Thermal block light
- Electronic keyboard with leds VOLT/AMPERE
- Terminal board with level control devices
- Cable gland
ADRY10 ADRY20
- Electronic signalling, control - Electronic signalling, control
and command card and command card equipped
- For the control of one electric pump with cyclic startings converter
- Weight : Kg 12-60 - For the control of two electric pumps
- Weight : Kg 15-85
Type of functioning
- Manual through general switch.
- Automatic through float switch.
Limits in use
- Environmental temperature: -5 / +40 °C
- Relative humidity : 50% at 40°C ADRY20
(without forming of condense)
- Standards : EN 60730 - EN 60439
Optional accessories
- CE040020 - Wall mount fixing fins
- UZA00200 - Optical, acoustic alarm
- Float switches (see accessories table)
248
Accessories
ACCESSORIES FOR CONTROL PANELS
PRESSURE SWITCH
CODE TYPE CONTROL PANELS
QES PLUS – QEC+S – QEM+S – QET+S
ZA003110 PM 5 ITL (6 Atm. Max) AD10 – AY10 – AR10
QES PLUS – QEC+S – QEM+S – QET+S
ZA006400 PM 12 ITL (12 Atm. Max) AD10 – AY10 – AR10
QES PLUS – QEC+S – QEM+S – QET+S
ZA000630 PM 6 TEL (6 Atm. Max) AD10 – AY10 – AR10
QES PLUS – QEC+S – QEM+S – QET+S
ZA000640 PM 12 TEL (12 Atm. Max) AD10 – AY10 – AR10
249
Accessories
250
Accessories
ZA003370 JOINT KIT 2,5 HEAT-SHRINK SPLICING KIT FOR CABLES UP TO 4 X 2,5 MM2
ZA003390 JOINT KIT 6 HEAT-SHRINK SPLICING KIT FOR CABLES UP TO 4 X 6 MM2
ACCESSORIES
ZA003380 JOINT KIT 10 RESIN FILLED SPLICING KIT FOR CABLES UP TO 4 X 10 MM2
ZA009410 JOINT 2,5 HEAT-SHRINK SPLICING JOINT FOR CABLES UP TO 4 X 2,5
ZA009430 JOINT 6 HEAT-SHRINK SPLICING JOINT FOR CABLES UP TO 4 X 6
ZA009450 JOINT 10 RESIN FILLED SPLICING JOINT FOR CABLES UP TO 4 X 10
251
Accessories
FILTERS AND FILTERING CARTRIDGES
CARTRIDGES BOWL
Min.
CODE DESCRIPTION quantity
ZB900060 CF 7” 1” CONNECTION 1
FILTERING CARTRIDGES
Nom. Min.
CODE DESCRIPTION filtr. µm quantity
252
Technical data subject to change without notice.
PENTAIR PUMPS S.p.A. reserves the right to carry out modifications to its products at any time without having to provide prior notice.
www.francoferrucci.com
50 Hz
Electric Pumps Catalogue