Professional Documents
Culture Documents
Appendix - D Hydroulic Calculation For New Booster Pumps Unit 4-5-6 Rev A
Appendix - D Hydroulic Calculation For New Booster Pumps Unit 4-5-6 Rev A
A
PUMP DESIGN CALCULATION SHEET
1/2
REV. DATE DESCRIPTION BY CHK'D APP'D
A 15-Apr-07 ISSUED FOR REVIEW ES AD HW
AWIBENGKOK 1, 2 & 3
3"x2" 2"
3"
AWI 7/8
3"x2" 2"
3"
AWI 7/8
4" 3"x2" 2"
3"
From P-401 A/B AWI 7/8
4"x3"
3" 4" 3"x2" 2"
3"
From P-501 A/B AWI 10/11/13
3"x2" 2"
From P-601 A/B 16.5 ft 3"
AWI 10/11/13
OPERATING CONDITIONS
1. Design Capacity 40.9 M3/Hr 8. Density 62.61 lb/ft3
9. Maximum Vapor Pressure 11.50 psia
2. Operation hours 24 Hours 10. Normal Viscosity 0.80 cP
3. No of operation pumps 1 Units 11. Capacity Maximum 40.9 M3/Hr
4. No of spare pumps 1 Units 180.1 GPM
5. Fluid Name Condensate 12. Capacity Overdesign 10 %
6. Normal Temperature 85 oF 13. Capacity Design 198 GPM
7. Normal Specific Gravity 1.00
14. Roughness Factor 4.60E-05 Commercial steel
DISCHARGE