Stair Detail - ST - 03

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

NOTES:-

B
A
1. ALL DIMENSIONS ARE IN FEET & INCHES.
2-16#
2. DO NOT SCALE THIS DRAWING.
LB 3. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL OTHER RELEVANT DRAWINGS.
4. REINFORCEMENT SHALL BE HIGH YIELD STRENGTH DEFORMED BARS COMPLYING
WITH IS:1786 (LATEST ISSUE) DESCRIBED AS # BARS AND MILD STEEL PLAIN
2-16# ROUND BARS CONFORMING TO IS: 432 DESCRIBED AS Ø BARS
8# 5. CONCRETE MIX SHALL BE M:20 FOR ALL STRUCTURE.
4"
ALL 6. CLEAR COVER TO MAIN REINFORCEMENT UNLESS NOTED SHALL BE AS FOLLOWS.
FOOTING 50mm.
LB
(9" X 1' 6" ) COLUMNS 40mm.
BEAMS AND PLINTH BEAM 30mm.
SLABS 20mm.
B
A

8#@ 7" C/C 7. NUMBER OF BAR SHOULD NOT BE COUNTED BUT SPACING INDICATED SHALL BE ADOPTED.
TYPICAL STAIR PLAN 10#@ 10" C/C 8. LAP IF REQUIRED SHALL BE 50 x DIA. OF BAR.
LANDING LVL.
9. STRUCTURAL ENGINEER IS NOT RESPONSIBLE FOR CENTERING, SHUTTERING,
2' 0
" QUALITY OF MATERIAL, WELDING & MISUNDERSTANDING OF DRAWING.

8#@ 7" C/C


LB 10#@ 10" C/C
2' 0
"

8#@ 7" C/C PLINTH LVL

HK.
10#@ 5" C/C

6" T
8#@ 7" C/C
SECTION A-A 10#@125C/C
TIE BEAM LVL
TIE BEAM ( TB7 )
(FOR DETAIL SEE
10#@ 10" C/C TIE BEAM LVL DRG.)
8#@ 7" C/C

2' 0
" F.F. LVL
10#@ 10" C/C
8#@ 7" C/C B11 ALTAF SHAIKH
2' 0
" (FOR DETAIL SEE
8#@ 7" C/C F.F. LVL DRG.)
6"
TH

LANDING LVL.
K.

10#@ 5" C/C 8#@ 7" C/C


LB 10#@ 5" C/C

SECTION B-B

You might also like