5"
5"
1’-9" 1’-9" 1’-9" 1’-9"
3"
3"
4"
4"
31.04"
35.62"
4" 4"
1’-5" 1’-5"
4" 4"
2’-9"
3’-6"
5’-3"
c.g.
63"
6’-0"
c.g.
72"
8" 10"
31.96"
8" 10"
10"
36.38"
10"
8"
8"
1’-2" 1’-2"
2’-4"
1’-2" 1’-2"
Weight : 7.0347 x 150 = 1055 lbs/ft. Weight : 7.5347 x 150 = 1130 lbs/ft.
4 4 4 4
I XX= 521,163 in. I YY
= 61,235 in. I XX= 733,320 in. I YY
= 61,619 in.
CT = 31.04 in. CB= 31.96 in. CT = 35.62 in. CB= 36.38 in.
3 3 3 3
ST= 16,788 in. SB= 16,308 in. ST= 20,588 in. SB= 20,157 in.
3’-7" 3’-7"
3 1/2 "
3 1/2 "
1’-9 1/2 " 1’-9 1/2 " 1’-9 1/2 " 1’-9 1/2 "
2"
2"
2"
2"
2" 2"
30.71"
35.21"
1’-6" 1’-6"
c.g.
63"
4’-6"
6’-0"
c.g.
72"
7"
7"
9 1/2 "
32.29"
36.79"
9 1/2 "
4 1/4 "
6 1/4 "
4 1/4 "
1’-1" 1’-1"
Weight : 5.3481 x 150 = 802 lbs/ft. Weight : 5.7856 x 150 = 868 lbs/ft.
4 4 4 4
I XX= 408,315 in. I = 40,308 in.
YY
I XX= 570,260 in. I = 40,566 in.
YY
CT = 30.71 in. CB= 32.29 in. CT = 35.21 in. CB= 36.79 in.
3 3 3 3
ST= 13,296 in. SB= 12,645 in. ST= 16,196 in. SB= 15,501 in.
FIGURE 6 - 67
1066 1066
127
127
76
76
102
102
788
102 102
905
431 431
102 102
838
1600
c.g.
1067
c.g.
1829
204 253
812
204 253
254
924
203
254
203
355 355
710
355 355
Weight : 0.654 x 23.6 = 15.424 kN/m Weight : 0.700 x 23.6 = 16.520 kN/m
9 4 9 4 9 4 9 4
I XX= 216.92 x 10 mm I = 25.49 x 10 mm
YY
I XX= 305.23 x 10 mm I = 25.65 x 10 mm
YY
1092 1092
89
51
51
51
51
51 51
780
894
457 457
89 89
1143
1600
c.g.
1372
1829
c.g.
178
178
241
820
935
241
108
158
330 330
108
660 158
330 330
0.497m 0.537m
Weight : 0.497 x 23.6 = 11.726 kN/m Weight : 0.537 x 23.6 = 12.685 kN/m
9 4 9 4 9 4 9 4
I XX= 169.95 x 10 mm I = 16.78 x 10 mm
YY
I XX= 237.36 x 10 mm I = 16.88 x 10 mm
YY