Air Conditioning System: PCSID1717
Air Conditioning System: PCSID1717
Air Conditioning System: PCSID1717
1. Blows horizontally
1
5.0–7.1 kW class 7.1–10.0 kW class 12.5–14.0 kW class
50%
reduction!
92kg
64kg
100
power consumption
Cooling seasonal
1,345
mm
990
50 mm
320mm
Previous non-inverter series New inverter RZF-C series 900mm 320mm 940mm
(average) (average)
(cassette type) (cassette type) R48NUY1 (In case of 14.0kW class) RZF140CYM4
right from the basic design to use CO 2 R-32 R-22 R-410A R-11 R-12 R-23
R-32.
(HFC) (HCFC) (HFC) (CFC) (CFC) (HFC)
*1. Source: Values for 100-year global warming potential (GWP) from IPCC Fourth Assessment Report. Comparative 100-year GWP: HFC410A, 2,090; HFC32, 675.
2
NEW Circulation Airflow Evenly Distributes
Airflow until now had areas that were either too cool or not cool enough.
Problem 1
Hot outdoor air entering through
windows and walls causes these
areas to become hot. 4-Way Flow
Problem Problem 2
Cool air accumulating directly Hot
outdoor
underneath causes cold air air
pockets at floor level.
Problem 3 1
Airflow blowing directly on people
causes discomfort for people in 3
the room.
Problem 4
Quick descent of cool air causes 4 2
insufficient cooling for corners of
the room.
Circulation airflow cools the entire room to deliver comfort that never feels cold.
During 2-way
horizontal flow
Hot
outdoor air
Cool air moves down along Comfort without cold air Cools by airflow blocking out
the walls and to every corner pockets at floor level. hot air near windows and walls.
of the room.
Note:
Cools areas around Cools entire room Cools areas around Cools entire room Results may vary depending on
walls using using 4-way walls using using 4-way equipment conditions, room size,
2-way horizontal flow swing flow 2-way horizontal flow swing flow and distance from indoor unit to walls.
3
Cool Air *1 *1. Applicable when wired remote controller BRC1E63 is used.
Comfort to the Entire Room with Even Temperatures and No Cold Air Pockets at Floor Level
30.0
4-way cassette (Swing) 29.0
Comparison Conditions
28.0 Room size:
27.0 Width 7.5m x depth 7.5m
26.0 x height 2.6m
25.0 Indoor unit capacity: 71 class
24.0 Outdoor air temperature: 35°C
23.0
22.0 Airflow rate and air direction:
high / swing
21.0
20.0
Full comfort is
provided with no
cold feet.
switches from 3-way horizontal flow to 4-way downward flow [swing] to Distance Minimum distance between
2-way horizontal flow to 4-way downward flow [swing].) to wall indoor units [Table 2] [Table 2]
[Table 1] Minimum distance between indoor units
Circulation airflow functions during connection with wired remote controller. 1.8m or more above floor surface Indoor unit
(BRC1E63). However, use is not possible for the following conditions: capacity FCF50-71 FCF100-140
- When a sealing material of air discharge outlet and branch ducts are used; Floor surface
Maximum
- When individual airflow setting is selected; distance 5m or more 7m or more
- When using group control other than round flow.
4
NEW Individual Airflow Direction Control *1 *1. Applicable when wired remote controller BRC1E63 is used.
Airflow direction can be individually Easy setting is possible with a wired remote controller.
adjusted for each air discharge outlet to
deliver optimal air distribution.
NEW
BRC1E63
When individual airflow is selected, airflow direction can be adjusted to room layout.
Swing
Swing is
selected for
areas near
the windows. No individual (Auto)
Auto is set for people
sitting farthest from
The seats here the entrance.
Sitting here is hot are comfortable
because of the hot air though…
from outside.
Position 0
For offices The airflow is at the
highest setting (Position 0)
for people who
Swing dislike air blowing
Discussions near Swing is set for directly on them.
a hot window meetings near
quickly heat up.
the windows.
5
NEW Daikin Sensing Technology *1,2 *1. Applicable when wired remote controller BRC1E63 is used.
*2. Applicable when sensing panel (BYCQ125EEF/EEK) is installed.
Dual Sensors*2
Dual sensors and individual airflow direction control automatically provide
optimal control of airflow.
Infrared presence sensor
The sensor detects the presence of people in each of the
4 areas.
With “Auto” airflow direction mode, flaps are controlled When presence is detected, air direction is set
to deliver optimal airflow when the room is unoccupied. to “Swing (narrow)” to deliver cool air to users.
6
Daikin provides your on-demand inv
Lineup P.9-10
Functions P.45-48
Specifications P.49-53
Options P.54-56
Dimensions P.57-68
Wall mounted type
Installation Service Space for Outdoor Unit P.69
8
Product Lineup
Cooling only
Series 50 60 71
NEW NEW NEW
CEILING MOUNTED
CASSETTE TYPE
Round Flow
Indoor unit
Outdoor unit
1 phase, 3 phase,
Power supply
220-240V, 50Hz 380-415V, 50Hz
9
100 125 140
NEW NEW NEW
Page
21
FCF100CVM4 FCF125CVM4 FCF140CVM4
RZF100CVM4 RZF100CYM4 RZF125CVM4 RZF125CYM4 RZF140CVM4 RZF140CYM4
Page
29
Page
31
Page
33
FBA100BVM4 FBA125BVM4 FBA140BVM4
RZF100CVM4 RZF100CYM4 RZF125CVM4 RZF125CYM4 RZF140CVM4 RZF140CYM4
NEW NEW NEW
Page
35
FHA100BVM4 FHA125BVM4 FHA140BVM4
RZF100CVM4 RZF100CYM4 RZF125CVM4 RZF125CYM4 RZF140CVM4 RZF140CYM4
NEW
Page
37
FAA100BVM4
RZF100CVM4 RZF100CYM4
Page
RZF100CVM4 RZF100CYM4 RZF125CVM4 RZF125CYM4 RZF140CVM4 RZF140CYM4 39
10
New Inverters launched
Cooling only
Energy Saving
Throughout the cooling season, NEW
Daikin’s new inverter models reduce energy consumption
Compared with previous non-inverter series, the new RZF-C series uses about 50% less power consumption
for quick and effective cooling that reduces electricity bills.
100
50%
reduction!
power consumption
Cooling seasonal
50
Note: Value 100 represents the amount of electricity used by a
non-inverter model during a similar annual cooling period.
What is CSPF?
CSPF is the value for the annual total cooling load divided by the annual total power consumption at outdoor
air conditions specified by ISO standard.
11
Compact & Lightweight
New outdoor units save even more space NEW
1,345
23% reduction
in volume
0.39m3 0.30m3
mm
990
mm
30% reduction
in weight
320mm
92kg 64kg
900mm 320mm 940mm
Previous
1,170 1,170 1,345
non-inverter 770 mm mm mm
R-NU series mm
900mm
900mm 900mm 900mm
New inverter
695 695 990
RZF-C 595
mm
mm mm mm
series
845mm 930mm 930mm
940mm
Capacity
INV Max
Non Max
Better performance
than non-inverter models!
Reaches maximum capacity faster
than usual inverter models.
Start Time
Start
Setting
temp.
Start Time
Indoor Removes
humidity humidity faster.
Start
Start Time
13
Benefits of Inverters
Total cost =
This results in lower total cost.
Inverters save more
energy over time
Time
Recovery point
Capacity
Load
In response to fluctuating cooling load, Non inverter On/Off operation
air conditioners repeatedly perform ON (full-power)/ Lower efficiency Inverter cooling capacity
OFF (zero-power) operation. Inverter air conditioners,
however, operate at optimal cooling capacity according
to the cooling load. Since inverter air conditioners Cooling load Partial load area
provide required minimum cooling capacity with
minimum electrical power, total power consumption 0
can be reduced during cooling period. 35
Outdoor ambient temperature (°C)
Continuous driving without stopping and starting is Constantly stopping and starting consumes energy
more fuel efficient. and is less fuel efficient.
Time
14
Durability
Overvoltage PCB Microchannel heat exchanger
(Outdoor unit option) See page 56
Microchannel technology utilises superior heat transfer
benefits of aluminium to create a more efficient air
Unstable power supply is a common problem in many conditioner.
regions. It can cause overvoltage which can significantly With a new resistance corrosion aluminium alloy, the
damage electronic devices. Daikin microchannel heat exchanger becomes highly
To prevent voltage fluctuations, it is usually necessary to durable.
attach a stabiliser when installing an air conditioner. A salt spray test has been conducted to demonstrate the
The RZF-C series is equipped with a highly-durable corrosion-resistant capability of our products in
electronic circuit. corrosive environments for a certain period of time.
This circuit eliminates the need for a stabiliser and offer
additional protection for devices in the outdoor unit, Test of durability
such as its fan motor and compressor. - Testing organization MTEC Thailand
- Testing standard ASTM B117
- Result
Outdoor unit installation is After undergoing an intensive test, the Daikin microchannel
heat exchanger is able to maintain its shape without
possible even with limited space corrosion, which strongly confirms its durability in a highly
corrosive environment.
15
Convenient Functions
Navigation remote controller BRC1E62/63 includes various
convenient functions
Automatic return to temperature preset by owner. Owner can preset upper and lower temperatures.
Setpoint auto reset Setpoint range set
- Even if the set temperature is - Saves energy by limiting the min.
changed, the new set and max. set temperature.
temperature returns to the - Avoids excessive heating or
previous preset value after a cooling.
preset duration of time. - This function is convenient if the
- Period selectable from 30, 60, remote controller is installed
90, or 120 minutes. where anyone can change the
settings.
Restaurant example
27 °C 24 °C Returns to
27 °C
automatically
Maximum power consumption can be set at 40, 60, 70, 80, or 100%.
Power
0
48
Sound (dB(A))
Rated
Operating
Quiet mode
44 Quiet mode
16
Reuse of Existing Piping
Benefit 1
Where feasible, we reduce work costs and time by reusing existing pipes*.
*Strict conditions apply, please check the table on page 39 for acceptable pipe sizing (if pipes are to be reused).
Benefit 2
You can increase cooling capacity and achieve higher energy efficiency
Upgrade to an air conditioner with the latest technology for greater comfort and energy efficiency.
R22 R32
Non inverter inverter
7.6 kW 14.0 kW
class class
Technology
Advanced technology, including the use of corrosion resistant electronic expansion valves, acid neutralisers and improved
compressor reliability, enables the re-use of existing piping* without the need of pipe flushing for a simplified replacement process.
Acid neutraliser
Filter or
accumulator
Acid (chlorine ion)
Compressor
Refrigerant pipe
*Strict conditions apply, please check the table on page 43 for acceptable pipe sizing (if pipes are to be reused).
17
Design Flexibility
Possible to forced OFF and ON/OFF operation using external command
*Field setting with remote controller
*Except for FFF and FDF series
Round flow cassette type Duct connection middle static pressure type
Lighting
Interlock
Interlock
Indoor units comply with D -Net standards *Except for FFF and FDF series
Adaptor not
required
Optional
FHQ-BV interface adaptor
is required FHA-B
VRV
VRV
Easy connection to DIII-NET and long piping length makes this solution suitable for projects including and SkyAir.
18
Smart Airflow Control
Indoor units can provide 5-step and 3-step fine control of air volume
5-step: FCF and FHA series
3-step: FBA and FAA series
Also convenient for high ceilings and spaces with long blow distances
*Field setting with remote controller
Cassette type <Round Flow>: Ceiling suspended type:
maximum 4.2 m* maximum 4.3 m
4.2 4.3
m m
19
Detail of Each Product Specification
DUCT CONNECTION
MIDDLE STATIC FBA-B Series Page 33
PRESSURE TYPE
20
CEILING MOUNTED CASSETTE TYPE Round Flow
Option
Accessory required for indoor unit.
NEW
BRC1E63
Note: Remote controller cable is not
included and must be obtained
locally.
NEW
Cooling only BRC7M635F
(Fresh white)
BRC7M635K
(Black)
Panel variations
Designer panel
(Fresh white)
Circulation Airflow
Cools the entire room to deliver comfort that never feels cold.
L-shaped Opposite
All-round flow 3-way flow
2-way flow 2-way flow
Note:
- Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow,
Required * an air discharge outlet sealing material (option) must be used to close each unused outlet.
distance to Minimum distance
wall surface - Operation sound increases when using 2-way or 3-way flow.
of 500mm
for closing - Designer panel cannot operate 2-way and 3-way flow.
* 200mm for corner
air discharge * closing
outlet Wall surface
22
CEILING MOUNTED CASSETTE TYPE Round Flow
Daikin Sensing Technology*1,2 *1. Applicable when sensing panel (BYCQ125EEF/EEK) is installed.
*2. Applicable when wired remote controller BRC1E63 is used.
Dual Sensors*1
Dual sensors and individual airflow direction control automatically provide
optimal control of airflow.
Infrared presence sensor
The sensor detects the presence of people in each of the
4 areas.
Ceiling height 2.7m 3.5m 4.0m
Detection range approx. approx. approx.
(diameter)*3 8.5m 11.5m 13.5m
*3. The infrared presence sensor detects 80cm above the floor.
Detecting the
presence of people
Infrared floor sensor
in each of the 4 areas
The sensor detects the floor temperature and
automatically adjusts operation of the indoor unit to
reduce the temperature difference between the ceiling
C and the floor.
B D
Ceiling height 2.7m 3.5m 4.0m
A
Detection range approx. approx. approx.
(diameter)*4 11m 14m 16m
*4. The infrared floor sensor detects at the floor surface.
Detecting the
Standard range for infrared presence sensor *
average temperature
of the floor
2.7m
ceiling
height
80cm
above floor 約8.5m
approx.8.5m
*[Concerning infrared presence sensor]
- People are detected by large movements such as the motion of people walking at a
certain distance away from sensor.
- Human detection is not possible for blind areas of sensor.
[Concerning infrared floor sensor]
- The detected temperature may sometimes be affected by a heat source, window, or
device emitting heat in the detection range.
With “Auto” airflow direction mode, flaps are controlled When presence is detected, air direction is set
to deliver optimal airflow when the room is unoccupied. to “Swing (narrow)” to deliver cool air to users.
23
Comfort and Energy Saving Preventing Overcooling*6 *6.Airflow direction and airflow
rate should be set to “Auto”.
Area around feet gets too cold because the air The floor temperature, Automatic control using
conditioner continues until the temperature near the which is lower than the temperature near the
ceiling reaches the set temperature. near the ceiling, is person as the room
detected. temperature.
Energy The temperature near the person is automatically calculated by detecting the temperature of the
savings floor. Energy is saved because the area around the feet does not get too cold.
Sensing Sensor Functions*7,8,9 *7. Applicable when sensing panel (BYCQ125EEF/EEK) is installed.
*8. These functions are not available when using the group control system.
*9. User can set these functions with remote controller.
*10
28 *10
28°C
27 27°C
26 26°C
26℃ 26°C
26℃ If people do not return,
Occupied Automatically reverts the air conditioner will
when people return. raise the set
Unoccupied temperature 1°C every
30 minutes and then
operate at 30°C.
Time
After 30 min After another 30 min
Shift temperature and time can be selected from 0.5 to 4°C in 0.5°C increments and 15, 30, 45, 60, 90 or 120 minutes respectively
with remote controller.
*10. On basic screen of remote controller, set temperature does not change.
24
CEILING MOUNTED CASSETTE TYPE Round Flow
Comfort
mm 95
Unified square panels 950 0m
m Same for
Panel size is the same for all models. all models
It is easy to maintain a neat appearance when multiple units are
installed in the same room.
Auto-swing
Note:
1
Air direction is set to the
standard position when the
5-level unit is shipped from the
air direction setting factory. The position can be
changed from the remote
controller.
The air direction is set automatically to the memorised 2
Closing of the corner
Auto air direction position of the previous air direction. discharge outlets is
control recommended.
Control of airflow rate has been improved from 3-step to 5-step. Indoor unit
Sound pressure level
Auto airflow rate is newly available. H HM M ML L
50-71C 37.0 34.5 32.0 29.5 27.5
100C 45.0 41.5 38.0 35.0 32.5
Suitable for high ceilings 125/140C 46.0 43.0 40.0 36.0 32.5
Even in spaces with high ceilings, a comfortable airflow is carried down to the floor level.
Standard Setting Setting Criteria for ceiling height and number of air discharge outlets
(Ceiling height is reference value)
Number of air discharge outlets used
50-71C 100–140C
3.6 4.2 All round 4-way 3-way 2-way All round 4-way 3-way 2-way
3.2 m flow flow flow flow flow flow flow flow
m m
Standard 2.7 m 3.1 m 3.0 m 3.5 m 3.2 m 3.4 m 3.6 m 4.2 m
Ceiling
High ceiling 3.0 m 3.4 m 3.3 m 3.8 m 3.6 m 3.9 m 4.0 m 4.2 m
height
High ceiling 3.5 m 4.0 m 3.5 m - 4.2 m 4.5 m 4.2 m -
Note:
When all round flow is selected, ceilings up to 4.2 m in height The aforementioned is for standard panels. See the installation manual for designer panels.
can be accommodated. (100-140C) Factory settings are for standard ceiling height and all-round flow.
High ceiling settings (1) and (2) are set with the remote controller by field setting.
High-efficiency filters are not available for high ceiling applications.
Humidity sensor
Not only temperature but also humidity is
detected, and adjustments are made for
comfortable air conditioning.
Cleanliness
Silver ion anti-bacterial drain pan Non-flocking flaps
A built-in antibacterial Flaps can be detached without use of tools.
treatment that uses silver Condensation does not easily
ion in the drain pan prevents form and dirt does not cling to
the growth of slime, non-flocking flaps.
bacteria, and mould that They are easy to clean.
cause odours and clogging.
(The lifespan of a silver ion
cartridge depends on the
Filter has anti-mould and
usage environment, but antibacterial treatment
should be changed once Prevents mould and microorganisms growing out of the
every two to three years.) dust and moisture that adheres to the filters.
25
Quick and Easy Installation Washer fixing plate
Washer
Designer panel
Easy Maintenance
The condition of the drain pan and Auto grille panel (option)
drain water Grille and air filter cleaning can be performed without need for
Can be checked by removing the suction grille and a stepladder by lowering the grille.
drain plug.
A dedicated remote controller for the auto grille panel (BRC16A2)
Note: For inquiries concerning auto grille panel installations, please
contact your local dealer or Daikin representative. is included.
Operation is not possible using BRC1E63.
27
Options
Options required for specific operating environments
Ultra long-life filter unit Fresh air intake kit Note 1.2
Even in dusty environments where the air conditioning Using this kit, a duct can be connected to take in outdoor
is constantly operating, the ultra long-life filter only has air. There are two chamber types that have intake in two
to be cleaned once a year. places: with T-duct joint and without T-duct joint.
Filter chamber Outside
(Can be used with high-efficiency filter)
T-duct joint
Available in two types: 65% and 90% colorimetry. (obtained locally)
Suction
Filter chamber chamber Intake duct
(obtained locally)
(Can be used with ultra long-life filter) (duct length: 4 m max.)
Connection
chamber
KDDP55B160K
Please use if you think the temperature and humidity T-duct joint
inside the ceiling exceeds 30°C and RH 80%, Suction
Intake duct
respectively. chamber
(obtained locally)
Connection (duct length: 4 m max.)
Top panel insulation(1) chamber
Top panel insulation(2) Direct installation type Note 6
Top panel insulation(3)
KDDP55X160A
Insulation for decoration panel
Side panel insulation
Suspension bracket insulation
28
COMPACT MULTI FLOW
CEILING MOUNTED
CASSETTE TYPE
Option
Accessory required for indoor unit.
BRC1E62
Note: Remote controller cable is not
included and must be obtained
locally.
29
Compact Comfortable
Sized to fit inside 600mm wide Designed for low draft
ceiling grids performance 0 Horizontal flow 0
575 mm
Less draft
575 mm can be felt
286 tion
mm Decolrais also
pane act.
comp
Consistent comfort throughout
700 mm Auto-swing operation Airfow direction can be
distributes conditioned air adjusted in accordance with
more evenly. room conditions.
700 mm
Auto-swing 5-levels air direction setting
Standard 0 0
setting Auto-swing Settable to 5 different levels
Fits without the need to 60
between 0 and 60 60
between 0 and 60
T bar
Multi-Flow System Air direction can
600 mm
600 mm
4-way flow be selected
according to installation.
1 pattern
3-way flow
Drain pump
750 mm
Equipped as standard accessory with
750 mm lift.
30
CEILING MOUNTED SLIM DUCT TYPE
NEW
FDF50/60BV14
Option
Accessory required for indoor unit.
BRC1E62
Note: Remote controller cable is not
included and must be obtained
locally.
Standard
31
Compact and Slim Design
Only 200 mm high
Easily installed in even shallow ceiling cavity with a
height of just 240 mm.
Indoor unit FDF50B FDF60B
200mm Height
Width
200 mm
1,100 mm
Depth 620 mm
620mm Weight 30 kg
1,100 mm
Bulkhead Installation
The slim duct type can be hidden inside the ceiling to provide a clean exterior. It is suitable for living rooms with shallow
tray ceilings or areas requiring a discreet appearance. FDF-B series are 900 and 1,100 mm wide, making them ideal for
narrow spaces.
All models are 200 mm high and require a space of only 240 mm between the drop ceiling and ceiling slab. With these
compact measurements, any unit can easily be installed in even shallow tray ceilings.
240 mm
Note:
1. To prevent an increase in operation sound, avoid installing the air suction grille
directly below the suction chamber.
2. Grilles, piping connections, ducts, and installation parts should be obtained
locally.
Duct-connected types do not have drain pumps.
32
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
Option
Accessory required for indoor unit.
BRC1E62
Note: Remote controller cable is not
included and must be obtained
locally.
Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)
When air conditioning two rooms Door-installed Wall-installed
Under-door cutout
simultaneously, the air discharged into ventilation grille ventilation grille
each room must be circulated back to
the air conditioner. To achieve this, a
ventilation duct should be installed for Partitioning wall
Ventilates air through
the partitioning wall.
each room or one of the indicated (See right)
ventilation grilles should be installed Ventilation grille Ventilation grille Under-door cutout
on the partitioning wall or under the
Note: The under-door cutout method should be used only when there is a small volume of airflow.
door between the rooms.
33
Design and Installation Flexibility
Only 245 mm high Adjustable E.S.P.
Installation is possible even in buildings External static pressure can be controlled to within a
with narrow ceiling spaces. range of 50 Pa to 150 Pa by using a DC fan motor.
245mm 50 Pa 150 Pa
One of the industry’s most compact Set to low static Set to high static pressure for
bodies in the mid-static pressure range. pressure when ducts advanced needs such as when
are short. using dampers and long ducts.
Indoor unit 50/60/71B 100/125/140B
Comfort airflow is achieved in accordance with conditions
Height (mm) 245
such as duct length.
Width (mm) 1,000 1,400
Depth (mm) 800
Clean
Inspection
opening for
drain pan
Drain pan
Option
Accessory required for indoor unit.
NEW
BRC1E63
Note: Remote controller cable is not
included and must be obtained
locally.
NEW
Cooling only BRC7M56
35
Stylish Model Installation Flexibility for
Freedom of Design
Sophisticated design
Flap neatly closes when not in use.
Flexible
White colour installation 30 mm 30 mm
The unit fits more or more or more
36
WALL MOUNTED TYPE
Option
Accessory required for indoor unit.
BRC1E62
Note: Remote controller cable is not
included and must be obtained
locally.
37
Compact & Sophisticated Design Design and Installation Flexibility
FAA100 6-direction refrigerant
9kg lighter FAQ100BV FAA100B
Height 360mm 340mm
piping offers Left pipe
340
greater
Width 1,570mm 1,200mm
mm
installation
1,200mm Depth 200mm 240mm
flexibility Back-left pipe
370mm shorter Weight 26kg 17kg Bottom-left pipe
Back-right pipe
Right pipe
Bottom-right pipe
Auto swing (up and down) and wide-angle Drain pump kit is available as option
louvers (left and right by hand) Installs onto side of unit.
Refrigerant
piping
Wide-angle louvers (by hand) 1,000 mm
Soft material louver bends airflow over
a wider area
Indoor unit
Drain pump kit
Comfort even on the far side of the room Using a 3rd-party building management system, air
conditioning and lighting can be interlocked.
To carry air to the far side of long
rooms, extra-high airflow adds 10% Lighting
more fan speed the "high" setting. Interlock
Air discharge strength is selected
from the remote controller by field
setting.
* Field setting with
remote controller
Switchable fan speed: 3 steps and Auto
DIII-NET communication
Programme "Dry" standard
Dehumidification is microprocessor controlled to prevent abrupt Connection to a centralised control system is
and uncomfortable changes in air temperature. available without need for an optional adaptor.
Easy Cleaning
Removable and Flat panel, easy to Non-flocking flaps
washable grille wipe dust off Condensation does not easily form
and dirt does not cling to non-flocking
flaps.
It is easy to clean.
38
OUTDOOR UNIT
Standard pipe size Same condition with standard pipe Piping length and chargeless piping length are shortened
Piping length and chargeless piping length are much shortened Cooilng capacity is lowered (pay attention to piping length)
Reuse of existing piping is not allowed
(dB(A))
initiate 8 hours after the peak Cooling
only
Rated2 Night Quiet
100
RZF50-71C 44
0
Rated
Operation
52 Quiet mode
Reducing noise will reduce capacity slightly. RZF125C 45 44 Quiet mode
Note : 1Anechoic chamber conversion value, measured according to JIS parameters RZF140C 54 45 8:00 12:00 16:00 20:00 0:00 4:00 8:00
and criteria. Note : Daikin date for RZF71C
Operating sound about 4 dB quieter
During operation these values are somewhat higher owing to ambient conditions.
2
Value when cooling. Value will differ when heating.
(RZF100-140CVM4, 71-140CYM4)
Power
Reluctance
Reluctance DC Motor
DC motor Swing compressor
Motor efficiency
Conventional tube and fin coil Micro channel coil Conventional heat Micro channel
exchanger heat exchanger
The diameter of the The diameter of the
refrigerant channel refrigerant channel
(holes where Flat, multi-hole (holes where refrigerant
refrigerant flows) is aluminium flows) is approx.1mm.
approx. 7mm heat exchanger
tubes
Approx. Approx.
7mm 1mm
Utilizing flat, multi-hole heat exchanger tubes increases
the heat exchange area and realizes energy savings.
Flow of refrigerant Flow of refrigerant
4 Fan
V-cut Propeller Fan (RZF50-100C)
40
REMOTE CONTROLLER Optional accessory
NEW
This simple, modern designed remote controller with
fresh white colour matches your interior design.
Operation is much easier and smoother, just follow
the indications on the navigation remote controller.
BRC1E63 BRC1E62
Energy saving
Setpoint auto reset Setpoint range set
- Even if the set temperature is changed, the new set temperature returns to the - Saves energy by limiting the
previous preset value after a preset duration of time. min. and max. set temperature.
- Period selectable from 30, 60, 90, or 120 min. - Avoids excessive heating or
Restaurant example cooling.
Restaurant opened Full tables at lunchtime After 30 minutes* - This function is convenient if
Temperature is set to 27ºC Then is lowered to 24ºC for Automatically returns to preset the remote controller is installed
crowded room temperature (27ºC) where anyone can change the
Returns to
settings.
27°C 24°C 27°C
automatically
- Sets and saves setting for an increment of time that automatically turns OFF air
conditioner after a preset period of time for each time operation starts.
- Period can be preset from 30 to 180 minutes in 10-minute increments.
Convenience
NEW 5-step airflow control (BRC1E63 only) Weekly schedule
- 5 actions per day can be scheduled
Energy consumption monitoring *1,2,3,4 for each day of the week.
- Past power consumption for the current and
- The holiday function will disable
previous days (2-hour intervals), week (1-day intervals),
schedule timer for the days that have
and year (1-month intervals) can be checked.
been set as holiday.
Note:
*1
Availability of this function may vary according to model (limited to partial - 3 independent schedules can be set.
functionality) (e.g. summer, winter, mid-season)
*2
Time setting is necessary.
*3
This function cannot be used during group control.
*4
This is a reference value for comparison and is not intended as a value for
investigation purposes in the calculation of electricity bills or contract for NEW Auto display off (BRC1E63 only)
electricity. Because it is a simple calculation of power consumption, there
are cases when the calculated value differs with the measurement results - While operation is stopping, LCD display can be turned OFF.
of a wattmeter. It will be displayed again if any button is pressed.
Setback (default: OFF) - Period can be preset from 10, 30, 60 minutes, and OFF.
Initial setting is 30 minutes.
- Maintains the room temperature in a specific range
during unoccupied periods by temporarily starting an
air conditioner that had been turned OFF.
41
control configurations and can control multiple indoor units.
Wireless LCD remote controller
The wireless remote controller is supplied in a set with a signal receiver.
NEW
Signal receiver unit of installed type is contained inside decoration panel
or indoor unit.
Shape of signal receiver unit differs according to the indoor unit.
Note: The signal receiver unit shown in the photograph is for mounting inside the decoration
panel of the ceiling mounted cassette type.
BRC7M635F
Signal receiver unit
(For ceiling mounted cassette type)
Remote controller is equipped with model name and failure display functions. This facilitates service in the unlikely event of a
malfunction.
(Model name display function applies to BRC1E62/63 only.)
SkyAir shares common control with Heat Reclaim Ventilator and the other Daikin air-conditioning
units, thus simplifying interlocking operations.
Easily adaptable to large-scale, high-function, centralised remote control systems.
Installing and connecting control wiring between SkyAir and other Daikin air-conditioning equipment is easy.
42
REMOTE CONTROLLER Optional accessory
For simultaneous
Group control control of up to 16
indoor units. Automatic address setting function Automatic address setting function
Signal receiver unit installed
on 1 indoor unit
Centralised control of
Centralised remote up to 64 indoor groups
control from remote location
up to 1 km away.
Interface adapter for SkyAir series (option) is Interface adapter for SkyAir series (option) is
required (See note 3) required (See note 3)
Note: 1BRC1E62 can connect to BRC1E62 only. BRC1E63 can connect BRC1E63 only. 2 When a wireless remote controller is used, it is not possible to use 2 wireless remote controllers.
Combination of BRC1E63 (main) and BRC7M (sub) is available. 3Compact multi flow cassette type (FFF) and Slim duct type (FDF) require interface adaptor for SkyAir series.
Centralised control, with setting as Centralised control of on/off by Unified control of weekly schedule With its high functionality, the full
simple as it is with a standard group or all at once for up to 256 for up to 1,024 indoor units. colour “all-in-one” graphic controller
remote controller, of up to 64 groups indoor units. Schedule timer sets on/off time in 1 minute units facilitates management of SkyAir
(1,024 indoor units) is possible. to be executed twice a day for a week at a time. System in a variety of ways.
Interface adaptor for SkyAir series Enables centralised control via connection to a The interface adaptor for SkyAir series is required for
high-speed, DIII-NET communication system, Compact multi flow cassette type (FFF) and Slim duct
DTA112BA51 (Option) adopted for the Daikin system. type (FDF).
Necessary for interface adaptor for SkyAir series with the central remote
control units shown at above.
43
Whatever your space, give it the comfort
it deserves
44
FUNCTIONS
CEILING MOUNTED COMPACT MULTI FLOW CEILING
CASSETTE TYPE Round Flow MOUNTED CASSETTE TYPE
10 Circulation airflow *3
11 Setback *1
12 Quick start *1
13 Individual airflow control *1
14 Infrared presence sensor Sensing panel
16 Humidity sensor
17 Auto airflow function *3 Sensing panel
Comfort
18 Auto swing
19 Swing pattern selection
20 Switchable fan speed 5 step 5 step 2 step 2 step
39 Auto-restart
40 Control by 2 remote controllers *8
48 High-efficiency filter
49 Ultra long-life filter
Options
50 Fresh air intake kit
51 Overvoltage PCB *4
Note: *1: Applicable when BRC1E62/63 is used *2: Not applicable when group control *3: Applicable when BRC1E63 is used
*6: Wiring adaptor for electrical appendices (and installation box) is necessary *7: Option is requied
45
CEILING MOUNTED DUCT CONNECTION MIDDLE CEILING SUSPENDED TYPE WALL MOUNTED TYPE
SLIM DUCT TYPE STATIC PRESSURE TYPE
10
11
12
13
14
15
16
17
18
19
20 2 step 2 step 3 step 3 step 5 step 5 step 3 step 3 step
21
22
23
24 3.5m / 4.3m
25
26 *7
27
28
29
30
31 *7 *7
32
33 *7
34
35
36
37
38
39
40 *8
41
42
43
44
45 *7
46
47 *7
48
49
50
51
*4: For outdoor units *5: Adaptor for Wiring (and installation box) is necessary
*8: It is not possible to use 2 wireless remote controllers. Combination of BRC1E63 (main) and BRC7M (sub) is available.
46
FUNCTIONS
Energy Saving
1. Energy consumption monitoring 6. Setpoint range set
Past power consumption is displayed for the current and previous Saves energy by limiting the minimum and maximum set temperatures.
days as well as in weekly and yearly intervals. Avoids excessive heating and cooling.
Comfort
10. Circulation airflow 19. Swing pattern selection
At the start of operation, airflow changes repeatedly between You can freely set air discharge settings by remote controller.
horizontal flow and downward flow (swing during cool operation), (1) Standard (2) Draft prevention (3) Ceiling soiling
and air is sent throughout the room to eliminate uneven setting setting prevention setting
temperatures.
11. Setback
Maintains the room temperature in a specific range during
unoccupied periods by temporarily starting an air conditioner that
had been turned OFF. 20. Switchable fan speed
High setting provides maximum reach while low setting minimises drafts.
12. Quick start
At operation start, capacity priority operation is possible. 21. Auto airflow rate
Airflow rate is automatically controlled in accordance with the
13. Individual airflow control difference between room temperature and set temperature.
Airflow direction can be individually adjusted for each air
discharge outlet to deliver optimal air distribution. 22. High fan speed mode
You can increase fan speed approximately 10% higher than the
14. Infrared presence sensor "high" setting.
The sensor detects the presence of people in each of the 4 areas.
47
Cleanliness
26. Anti-bacterial air filter 28. Silver ion anti-bacterial drain pan
The air filter has an anti-bacterial treatment to help prevent the A built-in antibacterial treatment that uses silver ion in the drain pan
growth of bacteria and mould on it. prevents the growth of slime, bacteria, and mould that cause odours
and clogging.
27. Mould-proof air filter
Sanitary filter has mould-resistant treatment. 29. Mould-proof drain pan
Mould-proof drain pan prevents growth of mould in highly humid
conditions.
Control
39. Auto-restart 43. External signal forced OFF and ON/OFF operation
If there is a power outage while the equipment is operating, The air conditioner can be interlocked with the keycard system and
operations will restart in the same mode as before the power turned ON/OFF by locking and unlocking the room.
cut when electricity is restored. The air conditioner can be also be turned OFF by the interlock with
the ventilation and lighting OFF signal.
40. Control by 2 remote controllers *Field setting with remote controller.
Using 2 remote controllers you can operate the equipment
locally or from a remote location. 44. External command control
*When a wireless remote controller is used, it is not possible to use 2 Operation and monitoring is carried out using the contact signal from
wireless remote controllers. the operation control box in the building monitoring room.
Combination of BRC1E63 (main) and BRC7M (sub) is available.
*Wiring adaptor for electrical appendices (and installation box) is necessary.
41. Group control by 1 remote controller
You can turn up to 16 indoor units ON/OFF with a single 45. Central remote control
remote controller. (When using connected indoor units, the Optional central remote controller enables centralised control of up to
settings must all be the same and on/off will be simultaneous.) 1024 indoor units (64 groups) from up to 1 km away.
42. External equipment interlock 46. Interlock control with Heat Reclaim Ventilator
Human presence is detected by the built-in infrared presence
Enables interlocking control with external equipment such as Heat
sensor in the sensing panel, and the presence detection
Reclaim Ventilator.
signal can be output and interlocked with external equipment.
Power conservation is possible though the interlock of
external equipment, such as lighting, with the infrared 47. DIII-NET communication standard
presence sensor. Connection to a centralised control system is available
*Adaptor for Wiring (and installation box) is necessary. without need for an optional adaptor.
Options
48. High-efficiency filter 50. Fresh air intake kit
Two types are available: 65% and 90% colorimetry. You can provide air-conditioning with fresh air from outside.
Convenient for places where a ventilation fan cannot be installed.
49. Ultra long-life filter
Requires no maintenance for about 4 years* (10,000h) in
51. Overvoltage PCB
stores and offices. Optional circuit eliminates the need for a stabiliser and offer additional
protection for devices in the outdoor unit, such as its fan motor and
*For dust concentration of 0.15 mg/m 3
compressor.
48
SPECIFICATIONS
49
(H) 16 / (L) 13.5 (H) 16 / (L) 13.5
51
CEILING SUSPENDED TYPE ( 1 Phase )
50 60 71 100 125 140
Indoor unit FHA50BVM4 FHA60BVM4 FHA71BVM4 FHA100BVM4 FHA125BVM4 FHA140BVM4
Model
Name Outdoor unit RZF50CVM4 RZF60CVM4 RZF71CVM4 RZF100CVM4 RZF125CVM4 RZF140CVM4
Power supply Outdoor unit 1 Phase, 220–240V / 220-230V, 50Hz / 60Hz
Cooling Capacity 1,2 5.0 6.0 7.1 10.0 12.5 14.0
Rated (Min. - Max.) kW (3.2-5.5) (3.2-6.0) (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.5)
17,100 20,500 24,200 34,100 42,700 47,800
Btu/h (10,900-19,100) (10,900-20,500) (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,900)
Power consumption Cooling kW 1.20 1.53 2.30 3.24 4.29 5.40
COP W/W 4.17 3.92 3.09 3.09 2.91 2.59
CSPF Wh/Wh 6.30 6.11 5.91 5.17 5.09 4.78
Indoor unit Colour White
Airflow rate m3/min 15.0 / 13.5 / 12.0 / 11.0 / 10.0 20.5 / 18.8 / 17.0 / 15.5 / 14.0 28.0 / 26.0 / 24.0 / 22.0 / 20.0 31.0 / 29.0 / 27.0 / 25.0 / 23.0 34.0 / 31.5 / 29.0 / 26.5 / 24.0
(H / HM / M / ML / L) cfm 530 / 477 / 424 / 388 / 353 724 / 664 / 600 / 547 / 494 988 / 918 / 847 / 777 / 706 1,094 / 1,024 / 953 / 883 / 812 1,200 / 1,112 / 1,024 / 935 / 847
Sound pressure level 3 (H / HM / M / ML / L) dB(A) 37.0 / 36.0 / 35.0 / 33.5 / 32.0 38.0 / 37.0 / 36.0 / 35.0 / 34.0 42.0 / 40.0 / 38.0 / 36.0 / 34.0 44.0 / 42.5 / 41.0 / 39.0 / 37.0 46.0 / 44.0 / 42.0 / 40.0 / 38.0
Dimensions (HXWXD) mm 235X960X690 235X1270X690 235X1590X690
Machine weight kg 25 32 38
Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white
unit Coil Type Micro channel
Compressor Type Hermetically sealed swing type
Motor output kW 1.30 1.60 2.40
Refrigerant charge (R32) kg 1.2(Charged for 30 m) 1.3(Charged for 30 m) 1.9(Charged for 30 m)
Sound Cooling dB(A) 48 49 52 54
pressure level 3
Night quiet mode dB(A) 44 45
Dimensions (HXWXD) mm 595X845X300 695X930X350 990X940X320
Machine weight kg 41 48 64
Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm 9.5
connections Gas (Flare) mm 15.9
Drain Indoor unit mm VP20 (I.D. 20XO.D. 26)
Outdoor unit mm 26.0 (Hole) 18.0 (Hole) 26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
Heat insulation Both liquid and gas piping
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
52
SPECIFICATIONS
53
OPTIONS
Indoor unit
CEILING MOUNTED CASSETTE TYPE < Round Flow >
Kit name
Name of option Remark
FCF50CVM4 FCF60CVM4 FCF71CVM4 FCF100CVM4 FCF125CVM4 FCF140CVM4
Standard panel with Fresh white BYCQ125EEF
Sensing Black BYCQ125EEK
Decoration Fresh white BYCQ125EAF
1 panel Standard panel
Black BYCQ125EAK
Designer panel 1 Fresh white BYCQ125EAPF
Auto grille panel 2,3 Fresh white BYCQ125EASF
Sealing material of air discharge outlet 4 1 Outlet KDBH551C160
2
2 Outlet KDBH552C160
3 Panel spacer KDBP55H160FA
Fresh air intake kit Chamber Without T-duct joint KDDP55B160 (Components: KDDP55C160-1, KDDP55B160-2) 8
4 type 5,6 With T-duct joint KDDP55B160K (Components: KDDP55C160-1, KDDP55B160K2) 8
Direct installation type 7 KDDP55X160A
High-efficiency filter unit 9 (Colorimetric method 65%) KAFP556C80 KAFP556C160
5 (Including filter chamber) (Colorimetric method 90%) KAFP557C80 KAFP557C160
Replacement high-efficiency filter 9,10 (Colorimetric method 65%) KAFP552B80 KAFP552B160
6
(Colorimetric method 90%) KAFP553B80 KAFP553B160
7 Filter chamber KDDFP55C160
8 Replacement long-life filter KAFP551K160
9 Replacement long-life filter (Auto grille panel) KAFP551H161
10 Ultra long-life filter unit (Including filter chamber) 9 KAFP55C160
11 Replacement ultra long-life filter 9,10 KAFP55H160H
12 Branch duct chamber 4 KDJP55C80 KDJP55C160
13 Insulation kit for high humidity 9,11 KDTP55K80 KDTP55K160
14 Remote controller Wireless type Cooling only BRC7M635F (Fresh white) / BRC7M635K (Black)
15 Navigation remote controller Wired type 12 BRC1E63
16 Central remote controller 13 DCS302CA61
17 Unified ON/OFF controller 13 DCS301BA61
18 Schedule timer 13 DST301BA61
19 Intelligent Touch Controller 13 DCS601C51
22 Adaptor for wiring 14 KRP1C11A
23 Wiring adaptor for electrical appendices 14 KRP4AA53
24 Installation box for adaptor PCB KRP1H98A
25 Remote sensor (for indoor temperature) KRCS01-5B
Note: 1When installing designer panel, body height (ceiling required dimension) is 42 mm higher than 7
The volume of fresh air for direct installation type is approximately 1% of the indoor unit airflow.
standard panel. Designer panel cannot operate 2 and 3 way flow. The chamber type is recommended when more fresh air is necessary.
2
A dedicated remote controller (BRC16A2) for the auto grille panel is included for lowering and 8
Please order using the names of both components instead of set name.
raising the suction grille. 9
This option cannot be installed to designer panel and auto grille panel.
3
When installing auto grille panel, body height (ceiling required dimension) is 55 mm higher than 10
Filter chamber is required.
standard panel. 11
Please use in case temperature/humidity inside ceiling may get over 30˚C, 80% RH.
4
Circulation airflow is not available with this option. 12
Wiring for wired remote controller should be obtained locally.
5
When installing a fresh air intake kit (chamber type), two air outlet corners are closed. 13
The indoor unit is equipped standardly with the interface adapter for SkyAir series. An option is unnecessary.
6
It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of 14
Installation box for adaptor PCB(KRP1H98A) is necessary.
the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the
operating sound and may also influence temperature sensing.
Round flow type: List of optional parts required to achieve different flow patterns
For each flow pattern – all round, 4-way, 3-way, 2-way, branch duct connection – the compatibility of each independently installed option
(shown in the column on the left) to accessory options (listed across the top of each table) is shown in the cells where the relevant row and column intersect.
A circle (o) indicates compatibility, and a cross (x) indicates incompatibility. Any options not shown below are not suitable for independent or accessory installation.
54
OPTIONS
Indoor unit
COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE
No. Kit name
Name of option Remark
FFF50BV14 FFF60BV14
1 Decoration panel BYFQ60B3W1
2 Sealing material of air discharge outlet KDBH44BA60
3 Panel spacer KDBQ44BA60A
4 Fresh air intake kit Direct installation type KDDQ44XA60
5 Replacement long-life filter KAFQ441BA60
6 Remote controller Wireless type Cooling only BRC7E531W
7 Navigation remote controller Wired type 1 BRC1E62
8 Central remote controller 2 DCS302CA61
9 Unified ON/OFF controller 2 DCS301BA61
10 Schedule timer 2 DST301BA61
11 intelligent Touch Controller 2 DCS601C51
12 Adaptor for wiring 3 KRP1BA57
13 Wiring adaptor for electrical appendices (2) 3 KRP4AA53
14 Installation box for adaptor PCB KRP1BA101
15 Remote sensor (for indoor temperature) KRCS01-1B
16 Interface adaptor for SkyAir series DTA112BA51
Note:
1
Wiring for wired remote controller should be obtained locally.
2
This optional accessory requires DTA112BA51.
3
Installation box for adaptor PCB (KRP1BA101) is necessaary.
Note:
1
Wiring for wired remote controller should be obtained locally.
2
Adaptor PCB (KRP413AB1S) is also required for each indoor unit.
3
Time clock and other devices should be obtained locally.
4
This optional accessory requires KRP928BB2S.
55
Indoor unit
CEILING SUSPENDED TYPE
No. Kit name
Name of option Remark
FHA50BVM4 FHA60BVM4 FHA71BVM4 FHA100BVM4 FHA125BVM4 FHA140BVM4
1 Replacement long-life filter Resin net KAFP501A56 KAFP501A80 KAFP501A160
2 Fresh air intake kit KDDQ50A140
3 Drain pump kit KDUP50Q160
4 L-type piping kit (for upward direction) KHFP5N160
5 Remote controller Wireless type Cooling only BRC7M56
6 Navigation Remote Controller Wired type 1 BRC1E63
7 Central remote controller 2 DCS302CA61
8 Unified ON/OFF controller 2 DCS301BA61
9 Schedule timer 2 DST301BA61
10 intelligent Touch Controller 2 DCS601C51
11 Adaptor for wiring 3 KRP1BA54
12 Wiring adaptor for electrical appendices 3 KRP4AA52
13 Installation box for adaptor PCB KRP1D93A
14 Adaptor box mounting plate KKSAP50A56 ----------
15 Remote sensor (for indoor temperature) KRCS01-4B
16 Electrical box with earth terminal (3 blocks) KJB311AA
17 Electrical box with earth terminal (2 blocks) KJB212AA
Note:
1
Wiring for wired remote controller should be obtained locally.
2
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
3
Installation box for adaptor PCB (KRP1D93A) is necessary.
Outdoor unit
Kit name
No. Name of option 1 Phase RZF50/60/71CVM4 RZF100CVM4 RZF125/140CVM4
3 Phase ---------- RZF71/100CYM4 RZF125/140CYM4
1 Central drain plug KKP014A4 KKP937A4 KKPJ5G280
2 Fixture for preventing overturning ---------- ---------- KKTP5B112
3 Wire fixture for preventing overturning ---------- ---------- K-KYZP15C
4 Demand adaptor ---------- KRP58M51 KRP58M51+EKMKSA1
Overvoltage PCB 1 Phase BRV2BPSF BRV2BPSS BRV2BPL
5
3 Phase ---------- BRV2BPSS+BRV2BPSS
56
DIMENSIONS (Unit: mm)
[FCF50-71CVM4]
20 20 20 20
4 - M4 6 6 4 - M4 B Connection position
950 Note) 3 Prepared hole Prepared hole of branch duct
860~910 (celing opening spec)(Note 4) 160 81 2x100=200 85
8
D
300 124 (Round shape type)
25 25 or less 710 (suspention position) 109 124
Pipe connection 95
94
94
side 420 C/L 16 - M4
E
10 Connection position Prepared hole
of branch duct
36
36
160
6 (Square-shaped type)
110
95
124
11 122
124
7
80 2x100=200 80
15 15 20 20 Connection position
350
25
Drain connection 4 - M4 5 6 4 - M4 of branch duct
122
350
side Prepared hole C C/L
Prepared hole Arrow view B (Square-shaped type)
10 25
213
94
94
Connection position
Arrow view A 9 of branch duct
ø10
36
36
(Round shape type)
(Kno 0
90
F ck h
Fresh air kit (direct type) ole)
Arrow view F Arrow view G Connection position 90
420 183
G
Arrow view C
Connection position
16 - M4 of branch duct Decoration panel
Adjustable (0~675)
110
124
105
95
60
5 your specify.
256
246
175
165
160
150
160
125
10
(Required space)
20 C/L 35 or less 256 2 Gas pipe connection
(Ceiling side-
40
122 (Note 4)
Humidifier drain pipe
122 3 Drain pipe connection
350 connection position 350
Suspention bolt Connection position 280 4 1 2 Connection position 35 or less
4 Power-source wiring and a unit wiring
130
330 of branch duct A
4 - M8~M10 of branch duct
(Round shape type) (Note 4) connection
(Round shape type)
5 Connection wiring /
Remote control wiring connection
6 Air outlet
7 Suction grille
8 Corner decoration cover
9 Sensor
10 Drain hose (accessory)
11 Drain hose connection port
Note:
1.Sticking location for Manufacture's label
Manufacture's label for Indoor unit : Suction grille inner side's electric components box's lid surface. INSTALLATION SPACE
a
Manufacture's label for Decoration panel : Decoration panel's corner decoration cover inner surface.
MORE
m OR
200m
2.In case of having option part built-in, please refer outside drawing of option part.
Fresh air kit.....................................................inspection hole Need a a
Natural evaporate type humidifier...................inspection hole Need
Air purifier unit.................................................inspection hole Need 200
mm
High performance filter unit.............................inspection hole No Need OR
MO
RE a
Branch duct chamber......................................inspection hole No Need
(both angle duct • circle duct)
- The necessary space is 500 mm or more when the air-outlet is
3.In case of using wireless remote controller. this position will be a signal receiver.
blocked with the accessory.
Refer to the drawing of wireless remote controller in detail.
Moreover when the corner areas are blocked (both right and
4.Though the installation is acceptable up to maximum of 910 mm square ceiling opening, keep the left of the blocked air outlet), the necessary space is 200 mm
clearance of 35mm or less between the indoor unit and the ceiling opening so that the panel overlap or more.
allowance can be ensured. - When the air-outlet is close to the wall surface (both sides of
the air-outlet), the recommended space is 2000 mm or more.
5.When the temperature and humidity in the ceiling exceed 30ºC and 80% RH or the fresh air is
inducted into the ceiling or the unit continues 24 hour operation, an additional insulation (thickness
10mm or more of glasswool or polyethylene form) is required.
6.Please do not place the thing been damp and troubled under an indoor unit. when the case where
humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.
7.If put vent hole, lighting, equipment near the air flow disturb equipment, ceiling surface may get dirty,
therefore shall install following to diagram as below.
1500 OR MORE
8. For fixing position of human detection and temp sensor will be follow to diagram instruction (can not change position).
Model 50-71 100-140
a 1500-5000 1500-7000
Valid b
Circulation 5000 or more 7000 or more
air flow a 1500 or more
Invalid
b 4000 or more
( 1)Lighting is targeted for exposed type (inverse fuji-shape etc.), for embedded type (type that not expose to ceiling surface), there is no restriction.
57
CEILING MOUNTED CASSETTE TYPE / Standard panel with Sensing
[FCF100-140CVM4]
20 20 20 20
6 6 4 - M4
4 - M4 Prepared hole B
950 Note) 3 Prepared hole 160 Connection position
8 860~910 (celing opening spec)(Note 4) 81 2x100=200 85
D
300 167 of branch duct
25 25 or less 710 (suspention position) 93 67 160 (Round shape type)
136
36 136
Pipe connection 95 C/L
side 420 16 - M4
10
E
Connection position 29
Prepared hole
of branch duct
36
6
160
(Square-shaped type)
93 67
20 - M4
95
780 (suspention position)
167
950 Prepared hole
29
Arrow view D Arrow view E
11
160
80 2x100=200 80
7 157
Connection position
Drain connection 15 350
25
15 20 20 of branch duct
157
350
side 5 C C/L (Square-shaped type)
4 - M4 6 4 - M4
Prepared hole Prepared hole Arrow view B
213
Arrow view A 9 10 25 Connection position
136
136
of branch duct ø10
90
(Round shape type) (Kn 0
F ock
36
36
ho le)
Fresh air kit (direct type) 90
420 Connection position 196
G
Arrow view F Arrow view G
Arrow view C
167
5 It can be chosen one of above 2 types depend on
93
95
105
29
60
your specify.
160
298
288
29
175
160
150
160
10
67
165
125
42
(Required space)
50
40
1500 or more
157
(Ceiling side-
hanger fixture height)
(Note 4) 157
Suspention bolt Connection position Humidifier drain pipe 3
4 - M8~M10 of branch duct
350 connection position 350 Drain pipe connection
280 4 1 2 Connection position 35 or less 4 Power-source wiring and a unit wiring
130
(Round shape type) 330 of branch duct A
(Round shape type) (Note 4)
connection
5 Connection wiring /
Remote control wiring connection
6 Air outlet
7 Suction grille
8 Corner decoration cover
9 Sensor
10 Drain hose (accessory)
11 Drain hose connection port
Note:
1.Sticking location for Manufacture's label
Manufacture's label for Indoor unit : Suction grille inner side's electric components box's lid surface. INSTALLATION SPACE
a
Manufacture's label for Decoration panel : Decoration panel's corner decoration cover inner surface.
MORE
m OR
200m
2.In case of having option part built-in, please refer outside drawing of option part.
Fresh air kit.....................................................inspection hole Need a a
Natural evaporate type humidifier...................inspection hole Need
Air purifier unit.................................................inspection hole Need 200
mm
High performance filter unit.............................inspection hole No Need OR
MO
RE a
Branch duct chamber......................................inspection hole No Need
(both angle duct • circle duct)
- The necessary space is 500 mm or more when the air-outlet is
3.In case of using wireless remote controller. this position will be a signal receiver.
blocked with the accessory.
Refer to the drawing of wireless remote controller in detail.
Moreover when the corner areas are blocked (both right and
4.Though the installation is acceptable up to maximum of 910 mm square ceiling opening, keep the left of the blocked air outlet), the necessary space is 200 mm
clearance of 35mm or less between the indoor unit and the ceiling opening so that the panel overlap or more.
allowance can be ensured. - When the air-outlet is close to the wall surface (both sides of
the air-outlet), the recommended space is 2000 mm or more.
5.When the temperature and humidity in the ceiling exceed 30ºC and 80% RH or the fresh air is
inducted into the ceiling or the unit continues 24 hour operation, an additional insulation (thickness
10mm or more of glasswool or polyethylene form) is required.
6.Please do not place the thing been damp and troubled under an indoor unit. when the case where
humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.
7.If put vent hole, lighting, equipment near the air flow disturb equipment, ceiling surface may get dirty,
therefore shall install following to diagram as below.
1500 OR MORE
8. For fixing position of human detection and temp sensor will be follow to diagram instruction (can not change position).
Model 50-71 100-140
a 1500-5000 1500-7000
Valid b
Circulation 5000 or more 7000 or more
air flow a 1500 or more
Invalid
b 4000 or more
( 1)Lighting is targeted for exposed type (inverse fuji-shape etc.), for embedded type (type that not expose to ceiling surface), there is no restriction.
58
DIMENSIONS (Unit: mm)
[FCF50-71CVM4]
20 20 20 20
4 - M4 6 6 4 - M4 B
950 Note) 3 Prepared hole Prepared hole 160 Connection position
8 860~910 (celing opening spec)(Note 4) 124 81 2x100=200 85
D
300 of branch duct
25 25 or less 710 (suspention position) 109 124 (Round shape type)
Pipe connection 95
36 94
420 C/L
94
side 9 16 - M4
E
Connection position Prepared hole
of branch duct
36
6
160
(Square-shaped type)
110
95
124
10 122
124
7
80 2x100=200 80
15 15 20 20 Connection position
Drain connection 350 of branch duct
25
4 - M4 5 6
350
122
side 4 - M4 C C/L (Square-shaped type)
Prepared hole
Prepared hole Arrow view B
213
10 25
Connection position
94
94
36
(Round shape type)
(Kn 0
90
36
G
Arrow view C
Connection position
of branch duct
Adjustable (0~675)
124 50
110
95
124
105
110
95
60
175
165
160
160
150
10
125
42
(Required space)
20 2 Gas pipe connection
1500 or more
(Ceiling side-
40
122 (Note 4)
Connection position Humidifier drain pipe 122
Suspention bolt 3
4 - M8~M10 of branch duct
350 connection position 350 Drain pipe connection
280 4 1 2 Connection position
(Round shape type) 35 or less 4 Power-source wiring and a unit wiring
130
330 of branch duct A
(Round shape type) (Note 4)
connection
5 Connection wiring /
Remote control wiring connection
6 Air outlet
7 Suction grille
8 Corner decoration cover
9 Drain hose (accessory)
10 Drain hose connection port
[FCF100-140CVM4]
20 20 20 20
6 6 4 - M4
4 - M4 Prepared hole B
Note) 3 Prepared hole
950 160 Connection position
8 300 860~910 (celing opening spec)(Note 4) 167 81 2X100=200 85
D
of branch duct
25 25 or less 710 (suspention position) 93 67 160
136
136
of branch duct
36
160
6 (Square-shaped type)
860-910 (celing opening spec)(Note 4)
93 67
20 - M4
95
167
950
Arrow view D
29
10
80 2X100=200 80
7 15 15
160
20 20 157
5 Connection position
Drain connection 4 - M4 6 4 - M4 350 of branch duct
25
350
157
213
Connection position
Arrow view A of branch duct
36
36
F (Kno 0
Fresh air kit (direct type) ck h
connection position ole)
Arrow view F Arrow view G 90
420 196
G
Connection position
Adjustable (0~675)
Arrow view C
16 - M4 of branch duct
Prepared hole (Square-shaped type)(Note 2)
Connection position 3
55 840 55 55 840 55 27 - M4
of branch duct
340 Prepared hole
(Square-shaped type) 64 81 2X100=200 85
80 2X100=200 80 Hanger
850
167
160
95
5
105
29
60
175
29
160
160
Note:
150
10
165
125
67
42
Hanger fixture
157 (Note 4)
1500 or more
59
CEILING MOUNTED CASSETTE TYPE / Designer panel
[FCF50-71CVM4]
20 20 20 20
950 Note) 3 4 - M4 6 6 4 - M4 B
8 Prepared hole Prepared hole 202 81 2X100=200 85 Connection position
860~910 (celing opening spec)(Note 4)
D
300 124 124 of branch duct
Pipe connection 25 25 or less 710 (suspention position) 109
side C/L (Round shape type)
95
94
94
420 16 - M4
9
E
6 Connection position Prepared hole
of branch duct
36
202
36
(Square-shaped type)
110
95
124
15 15 20 20 10
124
80 2X100=200 80
122 Connection position
Drain connection 4 - M4 5 6 4 - M4 350 of branch duct
25
side Prepared hole
Prepared hole
122
350
C C/L (Square-shaped type)
10 Arrow view B
25
94
94
213
Arrow view A Connection position
of branch duct
36
36 (Round shape type) O10
90
F Fresh air kit (direct type) (Kno 0
ck h
connection position ole)
Arrow view F Arrow view G 90
420 225
G
Connection position of branch duct Arrow view C
Adjustable (0~675)
16 - M4 (Square-shaped type)(Note 2)
Prepared hole Connection position 3
55 840 55 of branch duct 55 840 55 20 - M4
(Square-shaped type) Prepared hole
340 81 2X100=200 85
80 2X100=200 80 64 Hanger
905
124
124
110
124 50
95
124
105
110
95
60
5
298
246
217
207
52
192
202
167
202
42
Decoration panel
C/L 35 or less 256
(Required space)
20 BYCQ125EAPF
97
Designer panel
45
1500 or more
Humidifier drain pipe 35 or less
Hanger fixture
Suspention bolt Connection position 350 350
4 1 2
Ceiling side-
4 - M8~M10 of branch duct connection position (Note 4)
280
(Round shape type) Connection position A
172
330 1 Liquid pipe connection
height)
of branch duct
(Round shape type) 2 Gas pipe connection
3 Drain pipe connection
4 Power-source wiring and a unit wiring
connection
5 Connection wiring /
Remote control wiring connection
6 Air outlet
7 Suction grille
8 Corner decoration cover
9 Drain hose(accessory)
10 Drain hose connection port
[FCF100-140CVM4]
20 20 20 20
950 Note) 3 4 - M4 6 6 4 - M4
Prepared hole B
8 Prepared hole 202 Connection position
860~910 (celing opening spec)(Note 4) 81 2X100=200 85
167
D
136
of branch duct
202
36
(Square-shaped type)
860-910 (celing opening spec)(Note 4)
93 67
950
20 - M4
95
167
7 Prepared hole
780 (suspention position)
10
160
15
80 2X100=200 80
15 20 20 157
Drain connection 5 Connection position
4 - M4 4 - M4 350 of branch duct
25
side 6
350
Prepared hole
157
213
O10
F Fresh air kit (direct type) (Kno 0
connection position ck h
ole)
Arrow view F Arrow view G 90
420 238
G
Connection position
Adjustable (0~675)
16 - M4 Arrow view C
of branch duct
Prepared hole
Connection position 3 (Square-shaped type)(Note 2)
55 840 55 55 840 55 27 - M4
of branch duct
340 (Square-shaped type) Prepared hole
80 2X100=200 80 64 81 2X100=200 85 Hanger
167
160
905
95
160 50
167
95
93
5
105
29
60
160
340
288
29
Decoration panel
52
217
202
202
192
67
42
167
207
(Note 4) 157
1 Liquid pipe connection
Hanger fixture
A
of branch duct 3 Drain pipe connection
172
60
DIMENSIONS (Unit: mm)
[FCF50-71CVM4]
20 20 20 20
8 6 6 4 - M4
950 Note) 3 4 - M4 B
Prepared hole Prepared hole 215 81 2X100=200 85 Connection position
300 860~910 (celing opening spec)(Note 4) 124
D
124 of branch duct
Pipe connection 25 25 or less 710 (suspention position) 109
side C/L (Round shape type)
94
94
420 95 16 - M4
10
E
Connection position Prepared hole
6 of branch duct
36
215
36
(Square-shaped type)
7
Arrow view E Prepared hole
110
95
124
15 15 11
124
80 2X100=200 80
20 20 122
Drain connection 4 - M4 5 6 Connection position
4 - M4 350
25
side Prepared hole of branch duct
Prepared hole
122
350
C C/L (Square-shaped type)
Arrow view B
10 25
94
94
213
9 Connection position
Arrow view A 36
36
of branch duct
(Round shape type) O10
90
F (Kno 0
Fresh air kit (direct type) ck h
connection position ole)
Arrow view F Arrow view G 90
420 238
G
Connection position Arrow view C
Adjustable (0~675)
16 - M4 of branch duct
Prepared hole 3 (Square-shaped type)(Note 2)
Connection position
55 55 of branch duct 55 840 55 20 - M4 OPTIONAL WIRELESS REMOTE CONTROLLER
840
340 (Square-shaped type) 81 2X100=200 85 Prepared hole 43 BRC16A2
80 2X100=200 80 64 Hanger
905
124
124
110
124 50
105
95
124
110
60
95
STOP ��
5
AUTO GRILLE
躩鎮詩跲���賻
UP 迣
DOWN覺
311
246
133
BRC16A2
65
230
220
215
215
205
EMERGENCY
180
42
LIFTING/LOWERING
LIFTING/LOWERING STAGE
(Required space)
20
105
(Note 4)
40
122
Hanger fixture
AUTO GRILLE
122
Ceiling side-
1500 or more
Suspention bolt Connection position 350 Humidifier drain pipe 350 35 or less
4 - M8~M10 of branch duct 4 1 2 connection position (Note 4) 18.5
280
height)
(Round shape type) Connection position
185
330 A AUTO GRILLE RECEIVER WIRELESS REMOTE CONTROLLER
of branch duct
(Round shape type)
Decoration panel
BYCQ125EASF Auto grille panel
[FCF100-140CVM4]
20 20 20 20
8 6 6 4 - M4
950 Note) 3 4 - M4 Prepared hole B
Prepared hole 215 Connection position
860~910 (celing opening spec)(Note 4) 81 2X100=200 85
167
D
136
Connection position
of branch duct Prepared hole
6
36
215
36
(Square-shaped type)
860~910 (celing opening spec)(Note 4)
93 67
7 20 - M4
950
95
167
Arrow view D
29
11
160
15
80 2X100=200 80
15 20 20 157
Drain connection 5 Connection position
4 - M4 4 - M4 350
25
213
9
Arrow view A Connection position
of branch duct
36
36
90
Arrow view C
Adjustable (0~675)
160 50 BRC16A2
95
167
95
93
105
5
29
60
STOP ��
160
AUTO GRILLE
躩鎮詩跲���賻
353
UP 迣
288
29
DOWN覺
65
230
215
215
205
67
42
180
220
133
BRC16A2
EMERGENCY
LIFTING/LOWERING
LIFTING/LOWERING STAGE
105
157
40
(Note 4)
Hanger fixture
157
Ceiling side-
350
1500 or more
Suspention bolt Connection position Humidifier drain pipe 350 35 or less AUTO GRILLE
Decoration panel
BYCQ125EASF Auto grille panel
61
COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE
[FFF50/60BV14]
89
ø1
00
B
150
6 8
700
4-M4 hole
Outdoor air intake
(Direct connection)
7
B Arrow view
Pipe connection side
Required space
ore ※
m or m
1500m
15
Adjustable(0~545)
or 00mm
mo
150 re
62.5 575 62.5 or m 0mm ※
ore
※
62.5 575 62.5 ore ※
m or m
295 or more
750
3 1 5 1500m
※ When the discharge grille is closeout,
the required space is 200mm or more.
(180)
285
260
205
183
145
(Required space)
25
5-45 5-45
4
1500 or more
Note)4.
BYFQ60B8W1
55
295 or more
196 172
Suspension bolt 211 A
4-M8~M10
Notes:
1
Sticking location for manufacture's label 1 Liquid pipe connection
Manufacture's label for indoor unit : on the bell mouth inside suction grille
2 Gas pipe connection
Manufacture's label for decoration panel : on the inner frame inside suction grille
2
In case of using wireless remote controller, this position will be a signal receiver. 3 Drain pipe connection
Refer to the drawing of wireless remote controller in detail. 4 Power supply connection
3
When the temperature and humidity in the ceiling exceed 30℃ and rh 80% or the fresh air 5 Remote control wiring / control wiring connection
Is inducted into the ceiling or the unit continues 24 hour operation,an additional
Insulation (thickness 10mm or more of glasswool or polyethylene form) is required. 6 Air discharge grille
4
Though the installation is acceptable up to maximum of 660mm square ceiling opening, 7 Suction grille
Keep the clearance of 5-45mm between the main unit and the ceiling opening so that 8 Drain hose (accessory)
The panel overlap allowance can be ensured.
[FDF50/60BV14]
20 or more
240 or more
(Suspension bolt pitch)
1100
620
500
Ceiling
60
300
<Service space>
8 26-o4.7hole
(All around)
10xP100=1000
1140 Allow view
(Suspension bolt pitch) Inspection door
(Ceiling opening)
Suspension bolt
4-m8~m10 1080
1060 130 63 24-m5 holes 10
21
57.5
12.5
10
90
100 47
170
180
170
153
200
160
100
80
7
23
30 330 9xP100=900
3 5 150 9
18-m4 holes 4 100 980
(All around)
90 1000
80 1020
<In case of back-suction>
24-m5 holes
(All around)
1 Liquid pipe connection
2 Gas pipe connection
6 3 Socket for drain
Notes: 4 Drain hose (standard accessory)
200
160
180
100
10
1.In case of back-suction, mount chamber cover to bottom side of the unit. 5 Control box
9xP100=900 130
9 In case of bottom-suction, mount chamber cover to back side of the unit. 6 Transmission wiring connector
50
20
10
980 100 2.Location of unit`s name plate: control box cover. 7 Power supply connection
1000 90 3.Mount the air filter at the suction side.
1020 80 (Select its colorimethod(gravity method) 50% or more.)
8 Suspension bracket
<In case of bottom-suction> It can not be equipped with air filter(accessory) 9 Air filter (standard accessory)
When connecting duct to suction side. 10 Protection net
62
DIMENSIONS (Unit: mm)
[FBA50-71BVM4]
Inspection hatch 2
30-φ4.7hole 134 630 10 450 or more CASE1) Control box
(All around) (Hanging bolt position) Inspection hatch 1
( Drain
300 or more
pan removal
and part exchange. )
(450x450)
Inspection hatch 3
200 or less
8 ※When can work enters (SAME AS THE INDOOR
UNIT SIZE +300 OR MORE)
the space under the unit,
inspection hatch 2 is Control box
unnecessary.
Control box
9 Inspection hatch Fig.A
Ceiling
1300 or more
11x65=715
1038(Hanging bolt position)
CASE 2),3)
1000 or more
Control box
835
Inspection hatch1
(450x450)
or less
20 or more
Air Air inlet
200
outlet Control box
13x65=845 800 or more 800 or more
1000
36-φ4.7hole Inspection hatch 2
500
Inspection hatch View B-1 View B-2
500
B
(All around) (SAME AS THE INDOOR Unit base
Ceiling UNIT SIZE OR MORE)
Suspention
200 or less
65
69
(All around)
450 or more
13
176
100
194
Notes:
Drain pan
1
Locations of Manufacturer's Label:Surface of a control box
5x156=780 26 2
Make sure to mount the air filter inside the air passage on
138
maintenance space
792
Control Box
the suction side. (Select Duct Collection Efficiency
Inspection hatch 1 815
450 or more 800 or more maintenance space <Gravimetric Method>50% or more.)
View 3
If the temperature and humidity in the ceiling is likely to
(Service space)
(From the Air outlet) exceed 30℃ and RH80%, strengthen heat insulation by
12 applying the additional insulation materials such as glass
3x50=150
(643 or less)
1 2 6 5 3
300 or less 499 wool or polyethylene that has thickness of 10mm or more.
2x50=100
207 Adjustable
4
Do not put things that should not get wet under the indoor unit.
850 or less
222
Air Air inlet
183
208
136
226
123
outlet (Note.2)
Provide service spaces for service work such as check and
6x150=900 maintenance of the control box and drain pump by one of the
60
91
38
(A case without
179 50
2500 or more
11
(Note.5)
977
the ceiling)
[FBA100-140BVM4]
44-φ4.7hole 134 630 10
(All around) (Hanging bolt position) 50-φ4.7hole
(All around) CASE1) Control box
8
9
300 or more
Inspection hatch 1
(450x450) Inspection hatch 3
200 or less
Inspection hatch 2
450 or more (SAME AS THE INDOOR
UNIT SIZE +300 OR MORE)
( Drain pan removal
and part exchange. ) Control box
Inspection hatch
1438(Hanging bolt position)
1400 or more
1235
unnecessary.
1400
(450x450)
20 or more
Control box
Air inlet 800 or more 800 or more
Air B Inspection hatch 2
Inspection hatch View B-2
500
Air outlet
Unit base
Fig. A-1
(Service space)
450 or more
53
65
69
176
100
194
Notes:
13 1
Locations of Manufacturer's Label:Surface of a control box
Control Box 26
maintenance space 7x156=1092
2
Make sure to mount the air filter inside the air passage on
138
699
2x50=100
2
207 Adjustable
1 6 5 Do not put things that should not get wet under the indoor unit.
850 or less
4
3
Dews may drop when humidity reaches over 80%, a drain
gets stuck or air filters are not clean.
5
Space for Service Works
226
208
245
Air inlet
60
222
183
Air (Note.2)
136
123
outlet Provide service spaces for service work such as check and
91 26-8x12 oblong hole maintenance of the control box and drain pump by one of the
38
300 or more
4 7
(A case without
2500 or more
300 1352
1377
1)Inspection hatch 1and 2(450x450) (Fig.A-1) and a space of
Drain pan maintenance 800
check hole 300mm or more under the unit. (Fig.A)
(From the Air inlet)
Note:Inspection hatch 2 is not needed when there is a space for
Ceiling Floor surface service work under the unit.
2)Inspection hatch 1(450x450) on the control box side, and
1 Liquid pipe connection 6 Remote control wiring connection 11 Socket(For maintenance) Inspection hatch 2 under the unit. (View B-1)
2 Gas pipe connection 7 Power supply wiring connection 12 Drain hose(Accessory) 3)Inspection hatch 3 under the unit and control box. (View B-2)
3 Drain pipe connection 8 Air discharge flange 13 Drain hose connection(Accessory) Provide enough space for maintenance and mount the drain
4 9 pan and control box.
Earth terminal(terminal in Control box) Air suction flange
Check the drawing of optional accessories when mounting
5 Control box(Inside) 10 Hanger optional accessories such as filter chamber and humidifier.
63
CEILING SUSPENDED TYPE
210
[FHA50/60BVM4] 156
Connection position of fresh air intake kit
105 φ100(Knock out hole)
18 17 20 16 120
102 9
131 57 90
35
157 63
92
175
87
163
30
100
90
189
115
210
195
40
63
bolt pitch)
(Hanging
116 51 60 134 59
12
260
10 Position slit hole for taking out in pipe back
(View from the front)
(Required space)
8
(Required space)
220
920 103
690 (Hanging bolt pitch) 19 15
5
Hanging bolt
5
4 11
175
4-M8~M10 1 5
197
91
131
197
235
(Required space)
300 or more
13 57
57 6 14
30 or more 960 30 or more φ 45
(Service space) (Service space)
Obstacle
The Front
Floor side Brand name plate 1 Air discharge grille
(Note.2) 2 Air suction grille
3 Air filter
4 Gas pipe connection
Drain piping connection VP20
6 5 Liquid pipe connection
(For left pipe)
6 Drain pipe connection
7 Earth terminal (inside the control box) (M4)
8 Hanger
9 Rear pipe penetration cover
268
268
221
214
[FHA71BVM4]
210 Connection position of fresh air intake kit
156
105 φ100(Knock out hole)
18 17 20 16 120
102 9
131 57 90
35
157 63
92
175
87
30
163
189
100
210
115
90
195
40
63
bolt pitch)
(Hanging
116 51 60 134 59
260
12
10
Position slit hole for taking out in pipe back
(Required space)
220
103
1230 19 15
690 (Hanging bolt pitch)
5
Hanging bolt 4 5 11
175
5
4-M8~M10 1
91
131
197
197
57
6
For height installation
300 or more
13 14
57 φ45
30 or more 1270 30 or more
(Service space) (Service space)
The Front 1 Air discharge grille
Obstacle Brand name plate
2 Air suction grille
Floor side (Note.2)
3 Air filter
4 Gas pipe connection
Drain piping connection VP20 5 Liquid pipe connection
6 6 Drain pipe connection
(For left pipe)
7 Earth terminal (inside the control box) (M4)
8 Hanger
9 Rear pipe penetration cover
268
268
221
214
64
DIMENSIONS (Unit: mm)
[FHA100-140BVM4]
210
156 Connection position of fresh air intake kit
105 120
18 17 20 16 102 φ100(Knock out hole)
9
131 57 90
35
157 63
92
87
30
163
189
100
90
210
175
115
195
40
63
bolt pitch)
(Hanging
116 51 60 134 59
260
10 12
Position slit hole for taking out in pipe back
(Required space)
(View from the front)
8
220
(Required space)
103
1550 19 15
690 (Hanging bolt pitch)
5
Hanging bolt
4-M8~M10 1 4 5 11
175
5
91
131
197
197
235
(Required space)
57
For height installation
14
300 or more
13 6
57 30 or more 1590 30 or more
(Service (Service φ45
space) space)
The Front
1 Air discharge grille
Obstacle Brand name plate
2 Air suction grille
Floor side (Note.2)
3 Air filter
4 Gas pipe connection
Drain piping connection VP20 5 Liquid pipe connection
(For left pipe) 6 6 Drain pipe connection
7 Earth terminal (inside the control box) (M4)
8 Hanger
9 Rear pipe penetration cover
268
268
221
214
[FAA100BVM4]
Piping direction
(Required space)
Approx.440
50 or more
242
240
7
(Required space)
340
Dimensions for
30 or more
full open
front panel
8
3
9 1 Piping direction Name plate Note)2 Piping direction 2500 or more 120 or less
2 50 or more 1200 50 or more
For installation
(Requred space) (Requred space) in high spaces
φ80 hole
Outside line
Piping and
φ80 hole Wiring intake
114
45
45
1 Front panel
65 6 Approx.400 89 2 Front grill
5 3 Air outlet
Approx.460
4 Gas pipe
Mounting location 4 Approx.465
Notes: 5 Liquid pipe
1
Location of unit's of Name Plate:Right side surface of casing 6 Drain hose
2
In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote contorller in detail. 7 Earth terminal
3
Please do not place the thing been damp and troubled under an indoor unit. when the case where humidity is 80% or more, 8 Right side pipe connection hole
and the drain outlet are choked up and the air filter are dirty, dew may fall. 9 Left side pipe connection hole
65
OUTDOOR UNIT // RZF50/60/71CVM4
Drain outlet
I.D.O 18 hose for connection
845 78
300
131 573.5
342
326
300
Earth terminal
7
60
105
144 20
Service port
Liquid stop vale
112
163
269
272
Drain outlet
21
94
200 Drain outlet
299
419
449
479
509
559
15 930 46 350
Handle
695
420
Power supply wiring intake
Control wiring intake
50
Grounding terminal
11
24
497
Drain outlet
Liquid stop valve
Service port
Gas stop valve
66
DIMENSIONS (Unit: mm)
30
(345~355)
350
320
55
37
38
30
91
160 620 160
30 940 3
4
7
2
6
1
990
7 5
5 6
5
55
60
55
340
339
223
95
95
95
84
53
53
89 19
53
89
19 80 52
7 6 142
145 13 67
8 90 16
16
68
3 Service port
5 4 Earth terminal
36
61 5 Refrigerant piping intake
262 6 Power supply wiring intake
416 7 Transmission wiring intake
595
8 Drain pipe connection
67
REMOTE CONTROLLER
Wireless type
Refrigerant
Piping side
Decoration
157
189
panel
Remote controller
holder
Remote control
COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE CEILING MOUNTED BUILT-IN TYPE CEILING SUSPENDED TYPE
• Receiver installation procedure DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE • Receiver installation procedure
Receiver
Drain piping Refrigerant piping • Receiver detail
side side 2-5x9 Slot
(Ceiling opening)
Receiver
83.5
120
106
72
Switch box
(field Supplied parts)
• Receiver
detail
BRC1E62/63
Remote controller dimensions Upper case Lower case
Installation method
A Exposed cord Conduit
Staple B Embedded cord C Embedded cord (use switch box)
Top left 19 19
Top center
42
outlet outlet
Operation
lamp
120
84
(Green)
40
84
84
40
68
Installation service space for outdoor unit (Unit: mm)
1 When there is an obstruction on the inlet side 2 When there is an obstruction on the outlet side
1) When the overhead space is open 1) When the overhead space is open
1 2
1. For single unit installation 1. For single
When there is an 1 2
unit installation
obstruction only
on the inlet side 0 rm
ore
50 ore 0o
or
m 50
re
mo 0 2. For multiple units installation (more than two units)
or 10 ore
50 m 10
or 0
mo or
When there are obstructions on 1 2 re 10
0
mo or
both sides re
1 2
25
0o
rm
ore
10 10 re
0o
rm 0o mo mo
re
ore rm or or
ore 00
25 ore 10 10 00
0
0o rm 0o 0
10 ore
1
rm 0o rm
ore 10 ore or
m
2) When there is an obstruction in the overhead space
1. For single unit installation
2. For multiple units installation An obstruction
ss ss
(more than two units) 10 o r le
in the overhead
0o
r le
0
mo or 500 space 50
1000 or more
When there are re 10
1000 or more
0
mo or 1 2
re
obstructions on
both sides 10
00
or
mo
re
re
20 mo
0o
rm 0 or
ore 30 re ore
mo rm
or
50
0 0o
50
1000 or more
1. For single unit installation
1000 or more
10
0
mo or
re
When there is an obstruction on the inlet side
ss
r le
1000 or more
1 s 2 0o
r les 50 10
0o
or more
0
50 mo or
1000
re
25
An obstruction 0o
rm
in the overhead ore
An obstruction re
space re
mo in the overhead mo
r or
0 0o space 00
10 10
ore
rm 0
0o 10 ore
10 m
or
3 When there are obstructions on both
When there are obstructions on the inlet side and
both lateral sides
the inlet and outlet sides
An obstruction
in the overhead ss
(When the obstruction on the outlet side is higher than the
1000 or more
s
les r le
or 0o unit itself)
1000 or more
0 space 50
50
1 2
1) When the overhead space is open
(There is no limit to the height of the obstruction on the
outlet side.)
or 150 or 150
mo re mo
re mo re 0 1. For single unit 1 2
or 250 0o
r or 150 15 ore
mo
re
15 mo
re or
m
installation
H
L
s
s 10 les 10
les 0
mo or or 0
1000 or more
0o
r
re 50
0 1 2 mo or
50 re 10
0
mo or
re
10
0o
rm
L
1 1 ore
or 000 or 000
mo mo 25
re re 0o
or 250 rm
ore 0 0
mo ore 20 ore 30 ore
re m m
0
20 ore 0o
r or or
m
or 250 m
2
or 00 30 00 00
mo or mo 10 ore 10 ore
re re or
m L H or
m
Note : As for other patterns of installation, please refer to Installation manual or Engineering Data Book.
69
MEMO
70
Warning Ask a qualified installer or contractor to install this product. Do not try to install the product by yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the user's manual carefully before using this product. The user's manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Specifications, designs and other content appearing in this brochure are current as of July 2017 but subject to change without notice.