AIR CONDITIONING SYSTEM


COOLING ONLY [50Hz]
NEW New Inverters Launched!

Standard panel Standard panel


with Sensing

Designer panel Standard panel Standard panel Auto grille


with Sensing panel

1. Blows horizontally

2. Strikes the wall Circulation airflow cools the entire


room to deliver comfort that never
feels cold.
3. Reaches every
corner of the room

Standard panel Designer panel


- Fresh White - - Fresh White -

1
5.0–7.1 kW class 7.1–10.0 kW class 12.5–14.0 kW class

Energy Saving Compact


Comparison of cooling seasonal power New outdoor units save even
consumption based on average CSPF more space
values

50%
reduction!
92kg

64kg
100
power consumption
Cooling seasonal

1,345
mm
990
50 mm

320mm
Previous non-inverter series New inverter RZF-C series 900mm 320mm 940mm
(average) (average)
(cassette type) (cassette type) R48NUY1 (In case of 14.0kW class) RZF140CYM4

From R-410A to R-32,


Another step towards lower global warming potential.
If you want a new HFC refrigerant 100-year global warming potential (GWP) of different refrigerants
with zero ozone depletion
potential, which also has a lower
global warming potential than
R-410A, use R-32. approx. 1/3
*1

Achieving new levels of energy 10,900


14,800
efficiency while responding to 4,750
environmental needs, Daikin has 1,810 2,090
redesigned the SkyAir series 1 675

right from the basic design to use CO 2 R-32 R-22 R-410A R-11 R-12 R-23
R-32.
(HFC) (HCFC) (HFC) (CFC) (CFC) (HFC)

*1. Source: Values for 100-year global warming potential (GWP) from IPCC Fourth Assessment Report. Comparative 100-year GWP: HFC410A, 2,090; HFC32, 675.

2
NEW Circulation Airflow Evenly Distributes
Airflow until now had areas that were either too cool or not cool enough.

Problem 1
Hot outdoor air entering through
windows and walls causes these
areas to become hot. 4-Way Flow
Problem Problem 2
Cool air accumulating directly Hot
outdoor
underneath causes cold air air
pockets at floor level.

Problem 3 1
Airflow blowing directly on people
causes discomfort for people in 3
the room.

Problem 4
Quick descent of cool air causes 4 2
insufficient cooling for corners of
the room.

Circulation airflow cools the entire room to deliver comfort that never feels cold.
During 2-way
horizontal flow
Hot
outdoor air

Airflow effectively avoids


blowing air directly on people.

Cool air moves down along Comfort without cold air Cools by airflow blocking out
the walls and to every corner pockets at floor level. hot air near windows and walls.
of the room.

Configurations of Circulation Airflow

Operation Performs repeatedly


(at start) Airflow
direction When the set
changes temperature is reached,
normal operation
(all-round flow) begins.

Note:
Cools areas around Cools entire room Cools areas around Cools entire room Results may vary depending on
walls using using 4-way walls using using 4-way equipment conditions, room size,
2-way horizontal flow swing flow 2-way horizontal flow swing flow and distance from indoor unit to walls.

3
Cool Air *1 *1. Applicable when wired remote controller BRC1E63 is used.

Comfort to the Entire Room with Even Temperatures and No Cold Air Pockets at Floor Level
30.0
4-way cassette (Swing) 29.0
Comparison Conditions
28.0 Room size:
27.0 Width 7.5m x depth 7.5m
26.0 x height 2.6m
25.0 Indoor unit capacity: 71 class
24.0 Outdoor air temperature: 35°C
23.0
22.0 Airflow rate and air direction:
high / swing
21.0
20.0

Areas at floor level are


cold while areas
around walls are hot.

Circulation Airflow (2-way horizontal + 4-way swing) ※2


Approx. 5% energy
savings by reducing
uneven temperatures
※2.Calculated under the following comparison
conditions: When the average temperature at a
height of 0.6m above the floor reaches set
temperature. (26°C)

Full comfort is
provided with no
cold feet.

Three Technologies That Achieved Circulation Airflow


1 Use of new wide flaps(Straight) 2 Optimizing airflow angle(Horizontally)
With new, larger flaps, a straighter trajectory for airflow The airflow angle was made more horizontal.
was achieved.
Conventional flap
Conventional flap New wide flap

New wide flap construction New wide flap


inhibits ceiling dirt and grime.
By tapering both flap ends, the
airflow that causes dirty ceilings is
directed downward.
Velocity
10%
3 Increased velocity in ※
increase!

2-way flow(Strongly) All-round Two-way


Velocity increased by making 2-way flow. flow flow
Powerful airflow was realized.
※.Other 2 outlets are controlled by changing the flap ※
direction (angle) to suppress airflow volume.

Things to remember when using circulation airflow


[Table 1]
Main points for use Installation conditions Distance to wall from indoor unit

Round flow Indoor unit


Effectiveness may differ according to room conditions, room size, capacity FCF50-71 FCF100-140
and distance to walls.
Maximum
distance Within 5m Within 7m
Airflow operation differs when using the designer panel. (Operation repeatedly
Wall surface

switches from 3-way horizontal flow to 4-way downward flow [swing] to Distance Minimum distance between
2-way horizontal flow to 4-way downward flow [swing].) to wall indoor units [Table 2] [Table 2]
[Table 1] Minimum distance between indoor units
Circulation airflow functions during connection with wired remote controller. 1.8m or more above floor surface Indoor unit
(BRC1E63). However, use is not possible for the following conditions: capacity FCF50-71 FCF100-140
- When a sealing material of air discharge outlet and branch ducts are used; Floor surface
Maximum
- When individual airflow setting is selected; distance 5m or more 7m or more
- When using group control other than round flow.

4
NEW Individual Airflow Direction Control *1 *1. Applicable when wired remote controller BRC1E63 is used.

Comfortable air conditioning for all room layouts and conditions

Airflow direction can be individually Easy setting is possible with a wired remote controller.
adjusted for each air discharge outlet to
deliver optimal air distribution.
NEW
BRC1E63

Position 0 There are


identification
(Fixed airflow to marks near
the air outlets.
highest position)
Remote controller
screen

Individual airflow settings


No individual
setting ・No individual setting (Auto airflow)
(Auto airflow) ・Position 0 (Highest point)
・Position 1
・Position 2
・Position 3
Swing Position 4 ・Position 4 (Lowest point)
(Up/down) (Fixed airflow to the ・Swing
lowest position)
Individual settings are possible as stated above.

When individual airflow is selected, airflow direction can be adjusted to room layout.

For shops and restaurant

Swing
Swing is
selected for
areas near
the windows. No individual (Auto)
Auto is set for people
sitting farthest from
The seats here the entrance.
Sitting here is hot are comfortable
because of the hot air though…
from outside.

Position 0
For offices The airflow is at the
highest setting (Position 0)
for people who
Swing dislike air blowing
Discussions near Swing is set for directly on them.
a hot window meetings near
quickly heat up.
the windows.

It’s quite pleasant


It is very cold here, when cold air isn’t
isn’t it?… Discussions also blowing on us.
go smoothly.

5
NEW Daikin Sensing Technology *1,2 *1. Applicable when wired remote controller BRC1E63 is used.
*2. Applicable when sensing panel (BYCQ125EEF/EEK) is installed.

Dual Sensors*2
Dual sensors and individual airflow direction control automatically provide
optimal control of airflow.
Infrared presence sensor
The sensor detects the presence of people in each of the
4 areas.

Ceiling height 2.7m 3.5m 4.0m


Detection range approx. approx. approx.
(diameter)*3 8.5m 11.5m 13.5m
*3. The infrared presence sensor detects 80cm above the floor.
Detecting the
presence of people
in each of the 4 areas Infrared floor sensor
The sensor detects the floor temperature and
C automatically adjusts operation of the indoor unit to
B D reduce the temperature difference between the ceiling
and the floor.
A
Ceiling height 2.7m 3.5m 4.0m
Detecting the
average temperature Detection range approx. approx. approx.
of the floor (diameter)*4 11m 14m 16m
*4. The infrared floor sensor detects at the floor surface.

Auto Airflow Function*5 *5.Airflow direction should be set to “Auto”.

Direct Airflow (default: OFF) Cooling Dry

When human presence is not detected When human presence is detected

Optimal air direction by “Auto”

Optimal air direction by “Auto” Swing (narrow)

With “Auto” airflow direction mode, flaps are controlled When presence is detected, air direction is set
to deliver optimal airflow when the room is unoccupied. to “Swing (narrow)” to deliver cool air to users.

6
Daikin provides your on-demand inv

Ceiling mounted cassette type Ceiling mounted cassette type


(Standard panel with Sensing) (Standard panel)

Ceiling mounted cassette type Compact multi flow ceiling


(Designer panel) mounted cassette type

Duct connection Duct connection


middle static pressure type middle static pressure type
7
erters with a variety of indoor units
INDEX
New Round Flow Cassette
Circulation Airflow P.3-4
Individual Airflow Direction Control P.5
Sensing Technology P.6

Installation Image P.7-8

Lineup P.9-10

Daikin SkyAir Series


Ceiling mounted slim duct type Energy Saving P.11
Compact & Lightweight P.12
Quick Cooling P.13
Benefits of Inverters P.14
Durability P.15
Convenient Functions P.16
Reuse of Existing Piping P.17
Design Flexibility P.18
Smart Airflow Control P.19
Special Situations P.19

Indoor Unit P.20

Ceiling Mounted Cassette type P.21-28


<Round Flow>
Compact Multi Flow Ceiling P.29-30
Mounted Cassette type

Ceiling suspended type Ceiling Mounted Slim Duct type P.31-32


Duct Connection Middle Static P.33-34
Pressure type
Ceiling Suspended type P.35-36
Wall Mounted type P.37-38

Outdoor Unit P.39-40

Remote Controller P.41-43

Functions P.45-48

Specifications P.49-53

Options P.54-56

Dimensions P.57-68
Wall mounted type
Installation Service Space for Outdoor Unit P.69

8
Product Lineup
Cooling only

Series 50 60 71
NEW NEW NEW
CEILING MOUNTED
CASSETTE TYPE
Round Flow

Indoor unit FCF50CVM4 FCF60CVM4 FCF71CVM4


Outdoor unit RZF50CVM4 RZF60CVM4 RZF71CVM4 RZF71CYM4
NEW NEW
COMPACT MULTI FLOW
CEILING MOUNTED
CASSETTE TYPE

Indoor unit FFF50BV14 FFF60BV14


Outdoor unit RZF50CVM4 RZF60CVM4
NEW NEW
CEILING MOUNTED
SLIM DUCT TYPE

Indoor unit FDF50BV14 FDF60BV14


Outdoor unit RZF50CVM4 RZF60CVM4
NEW NEW NEW NEW NEW
DUCT CONNECTION
MIDDLE STATIC
PRESSURE TYPE

Indoor unit FBA50BVM4 FBA60BVM4


FBA50BVMA FBA71BVM4
FBA60BVMA
Outdoor unit RZF50CVM4 RZF60CVM4
RZR50MVMRZF71CVM4RZR60MVM
RZF71CYM4
NEW NEW NEW
CEILING SUSPENDED TYPE

Indoor unit FHA50BVM4 FHA60BVM4 FHA71BVM4


Outdoor unit RZF50CVM4 RZF60CVM4 RZF71CVM4 RZF71CYM4

WALL MOUNTED TYPE

Indoor unit
Outdoor unit

NEW NEW NEW NEW


OUTDOOR UNIT

Outdoor unit RZF50CVM4 RZF60CVM4 RZF71CVM4 RZF71CYM4

1 phase, 3 phase,
Power supply
220-240V, 50Hz 380-415V, 50Hz

9
100 125 140
NEW NEW NEW

Page
21
FCF100CVM4 FCF125CVM4 FCF140CVM4
RZF100CVM4 RZF100CYM4 RZF125CVM4 RZF125CYM4 RZF140CVM4 RZF140CYM4

Page
29

Page
31

NEW NEW NEW

Page
33
FBA100BVM4 FBA125BVM4 FBA140BVM4
RZF100CVM4 RZF100CYM4 RZF125CVM4 RZF125CYM4 RZF140CVM4 RZF140CYM4
NEW NEW NEW

Page
35
FHA100BVM4 FHA125BVM4 FHA140BVM4
RZF100CVM4 RZF100CYM4 RZF125CVM4 RZF125CYM4 RZF140CVM4 RZF140CYM4
NEW

Page
37
FAA100BVM4
RZF100CVM4 RZF100CYM4

NEW NEW NEW

Page
RZF100CVM4 RZF100CYM4 RZF125CVM4 RZF125CYM4 RZF140CVM4 RZF140CYM4 39

1 phase, 3 phase, 1 phase, 3 phase, 1 phase, 3 phase,


220-240V, 50Hz 380-415V, 50Hz 220-240V, 50Hz 380-415V, 50Hz 220-240V, 50Hz 380-415V, 50Hz

10
New Inverters launched

Cooling only

Energy Saving
Throughout the cooling season, NEW
Daikin’s new inverter models reduce energy consumption
Compared with previous non-inverter series, the new RZF-C series uses about 50% less power consumption
for quick and effective cooling that reduces electricity bills.

Comparison of cooling seasonal power consumption


based on average CSPF values

100
50%
reduction!
power consumption
Cooling seasonal

50
Note: Value 100 represents the amount of electricity used by a
non-inverter model during a similar annual cooling period.

Previous non-inverter series New inverter RZF-C series


(average) (average)
(cassette type) (cassette type)

CSPF values by capacity for cassette models


New inverter RZF-C series R32 <cassette type>
CSPF Previous non-inverter series R22 <cassette type>
7
Value *CSPF (cooling seasonal performance factor) is a new
international energy-efficiency criterion calculated by
6 6.60 6.31 methods stipulated in ISO 16358-1.
6.17
5 5.50 5.15 5.00
4
3
2.77 2.69 2.79 2.79 2.73
2 2.63
1
0
Inverter RZF50CVM4 RZF60CVM4 RZF71CVM4 RZF100CYM4 RZF125CYM4 RZF140CYM4

Non Inverter R18NUV1 R21NUV1 R26NUV1 R36NUY1 R42NUY1 R48NUY1

What is CSPF?
CSPF is the value for the annual total cooling load divided by the annual total power consumption at outdoor
air conditions specified by ISO standard.

11
Compact & Lightweight
New outdoor units save even more space NEW

92kg More compact,


much higher CSPF!
64kg

1,345
23% reduction
in volume
0.39m3 0.30m3
mm
990
mm

30% reduction
in weight
320mm
92kg 64kg
900mm 320mm 940mm

R48NUY1 (In case of 14.0kW class) RZF140CYM4

Comparison with the previous mainstream non-inverter series


Outdoor units are much more compact and lighter weight.
They enable easy installation in places with limited space.

7.6 kW 10.6 kW 12.3 kW 14.1 kW


R26NUV1 / NUY1 R36NUV1 / NUY1 R42NUY1 R48NUY1
70kg 79kg 87kg 92kg

Previous
1,170 1,170 1,345
non-inverter 770 mm mm mm

R-NU series mm

900mm
900mm 900mm 900mm

7.1 kW 10.0 kW 12.5 kW 14.0 kW


RZF71CVM4 RZF71CYM4 100CVM4 /CYM4 RZF125CVM4 /CYM4 RZF140CVM4 /CYM4

41kg 48kg 48kg 64kg

New inverter
695 695 990
RZF-C 595
mm
mm mm mm

series
845mm 930mm 930mm
940mm

Reduced by 29kg 22kg 31kg 23kg 28kg


Unit weight is greatly reduced.
12
Quick Cooling
Faster cooling and dehumidification NEW Quick cooling start function
New inverter control technology brings quick comfort. Quickly and easily make space comfortable before
the arrival of office workers or shop customers.
As well as quick cooling at maximum capacity, new
inverter control rapidly removes indoor humidity.
More than simple temperature reduction, this twin
reduction provides greater comfort (within a maximum
New Inverter (RZF-C series) of 30 minutes).
Usual Inverter (RZR-L series)
Non inverter

Capacity

INV Max

Non Max

Better performance
than non-inverter models!
Reaches maximum capacity faster
than usual inverter models.

Start Time

BRC1E62/63 wired remote controller


Indoor is used for ‘Quick cooling start’.
Reaches the
temp.
set temperature faster.

Start

Setting
temp.
Start Time

Indoor Removes
humidity humidity faster.

Start

Start Time

13
Benefits of Inverters

Why is inverter technology economical?


Inverter system consumes less

unit price + cost of electricity


electricity, and soon recovers the Non inverter Inverter
difference in initial cost.

Total cost =
This results in lower total cost.
Inverters save more
energy over time

Time
Recovery point

Inverter air conditioner can adjust its Rated condition


cooling capacity according to the
cooling load. This results in less
power consumption. Non inverter cooling capacity

Capacity
Load
In response to fluctuating cooling load, Non inverter On/Off operation
air conditioners repeatedly perform ON (full-power)/ Lower efficiency Inverter cooling capacity
OFF (zero-power) operation. Inverter air conditioners,
however, operate at optimal cooling capacity according
to the cooling load. Since inverter air conditioners Cooling load Partial load area
provide required minimum cooling capacity with
minimum electrical power, total power consumption 0
can be reduced during cooling period. 35
Outdoor ambient temperature (°C)

Inverters operate without repeated ON/OFF operation.


Inverter Highway driving Non inverter City driving
Stop, go, stop ...

Continuous driving without stopping and starting is Constantly stopping and starting consumes energy
more fuel efficient. and is less fuel efficient.

Why is inverter technology more comfortable?


Non inverter Inverter
When temperature does not
fluctuate much, the set
temperature is maintained.
Inverter control responds to load changes
and causes minor temperature adjustments. Room
temperature Too hot
Non-inverter control frequently turns ON and
OFF in response to load fluctuations or load Large
temperature
mismatch and causes large temperature fluctuation
swings.
Set
temperature
Non inverter
Comfortable
Small
temperature
fluctuation
Inverter
Non inverter
Too cold Too cold

Time

14
Durability
Overvoltage PCB Microchannel heat exchanger
(Outdoor unit option) See page 56
Microchannel technology utilises superior heat transfer
benefits of aluminium to create a more efficient air
Unstable power supply is a common problem in many conditioner.
regions. It can cause overvoltage which can significantly With a new resistance corrosion aluminium alloy, the
damage electronic devices. Daikin microchannel heat exchanger becomes highly
To prevent voltage fluctuations, it is usually necessary to durable.
attach a stabiliser when installing an air conditioner. A salt spray test has been conducted to demonstrate the
The RZF-C series is equipped with a highly-durable corrosion-resistant capability of our products in
electronic circuit. corrosive environments for a certain period of time.
This circuit eliminates the need for a stabiliser and offer
additional protection for devices in the outdoor unit, Test of durability
such as its fan motor and compressor. - Testing organization MTEC Thailand
- Testing standard ASTM B117
- Result

Automatic protection against Before testing After testing


low voltage
In AM and PM peak electricity consumption periods,
supply may fluctuate. Built-in low-voltage protection will
automatically cut operations. When normal voltage is
restored, operation will resume as before. Normal Under
observation telescope
No evidence of corrosion was observed

Outdoor unit installation is After undergoing an intensive test, the Daikin microchannel
heat exchanger is able to maintain its shape without
possible even with limited space corrosion, which strongly confirms its durability in a highly
corrosive environment.

Coated printed circuit boards


(outdoor unit)
100 Coated circuit boards
m or prevent problems
mo m or m me
re 0 r
100
m 10 mo or
caused by humidity
mo m or m me and airborne dust.
re 0 r
50 mo It also protects against
salt contained in sea
breezes.
Both sides of the PCB
in outdoor units are
coated.

Self-diagnosis functions enable


prompt maintenance response
An error message appears on the LCD of the remote
controller and an LED lights up on the unit.
When the BRC1E62/63 is installed, the error code
appears showing contact information and model name.
Contact your Daikin dealer and provide the error code
and model name.

15
Convenient Functions
Navigation remote controller BRC1E62/63 includes various
convenient functions
Automatic return to temperature preset by owner. Owner can preset upper and lower temperatures.
Setpoint auto reset Setpoint range set
- Even if the set temperature is - Saves energy by limiting the min.
changed, the new set and max. set temperature.
temperature returns to the - Avoids excessive heating or
previous preset value after a cooling.
preset duration of time. - This function is convenient if the
- Period selectable from 30, 60, remote controller is installed
90, or 120 minutes. where anyone can change the
settings.

Restaurant example

Restaurant opened Full tables at lunchtime After 30 minutes*

27 °C 24 °C Returns to
27 °C
automatically

Temperature is set to 27ºC Then is lowered to 24ºC Automatically returns to


for crowded room preset temperature (27ºC)
*Preset-return time can be set at 30, 60, 90, or 120 min

Demand control function


* RZF100-140CVM4, 71-140CYM4
By setting limits that restrict power consumption, you can cut electricity bills.
* Field setting with remote controller
- Power consumption is given first priority, and limits maximum power * Required for KRP58M51 (Option)
consumption of unit. Limitation
consumption

Maximum power consumption can be set at 40, 60, 70, 80, or 100%.
Power

8:00 12:00 16:00 20:00 Time

Night quiet operation mode


Consideration is given for people living nearby.
Outdoor unit operating sound can be reduced. *Field setting with remote controller
Peak outdoor temperature
Capacity (%)

The operating 100


noise bothers 8 hours
me at night! 50 10 hours
Load (%)

0
48
Sound (dB(A))

Rated
Operating

Quiet mode
44 Quiet mode

8:00 12:00 16:00 20:00 0:00 4:00 8:00

Note: Daikin data for RZF71C


Operating sound about 4 dB quieter

16
Reuse of Existing Piping
Benefit 1

Simplified installation reduces replacement time and cost

When considering air conditioner replacement, do the following


things concern you?

The length of time the business will be closed


Effect on sales during replacement work
High costs and long work period due to scaffolding needed for pipe replacement

These problems are solved by Daikin!

Where feasible, we reduce work costs and time by reusing existing pipes*.

*Strict conditions apply, please check the table on page 39 for acceptable pipe sizing (if pipes are to be reused).

Benefit 2

You can increase cooling capacity and achieve higher energy efficiency
Upgrade to an air conditioner with the latest technology for greater comfort and energy efficiency.

R22 R32
Non inverter inverter
7.6 kW 14.0 kW
class class

φ9.5 φ15.9 φ9.5 φ15.9


Pipes used
as they are!

As a result, the greater capacity units


FHC26NUV1 FCF140CVM4 ensure better performance to cope
R26NUV1 RZF140CVM4
with the increasing amount of heat
CSPF: 2.63 CSPF: 5.00 generated by office equipment and
occupants.

Technology
Advanced technology, including the use of corrosion resistant electronic expansion valves, acid neutralisers and improved
compressor reliability, enables the re-use of existing piping* without the need of pipe flushing for a simplified replacement process.

Stronger refrigerating Highly corrosion resistant Highly reliable


machine oil electronic expansion valve compressor

An acid neutraliser agent is added to disable Compressor durability is improved


acids (chlorine ions), which cause corrosion. by installing a filter or accumulator
to collect solid foreign substances.

Acid neutraliser
Filter or
accumulator
Acid (chlorine ion)
Compressor

Refrigerant pipe

*Strict conditions apply, please check the table on page 43 for acceptable pipe sizing (if pipes are to be reused).

17
Design Flexibility
Possible to forced OFF and ON/OFF operation using external command
*Field setting with remote controller
*Except for FFF and FDF series

Round flow cassette type Duct connection middle static pressure type
Lighting

Interlock

Interlock

External Equipment Interlock (FCF-C series only)


Power conservation is possible though interlock* of external equipment, *Optional adaptor for wiring: KRP1C11A is necessary.
such as lighting, with the infrared presence sensor.
Human presence is detected by the built-in infrared Sensor The presence detection signal of the infrared presence sensor
presence sensor in the sensing panel, and the interlock can turn only external equipment ON/OFF without interlocking
mode with air conditioner operation/stop (ON/OFF).
presence detection signal can be output and interlocked
with external equipment such as ventilation and lighting
equipment.

External equipment also


Presence Sensor Sensor automatically turns ON/OFF.
detection Undetected Detected
signal Contact OFF Contact ON Further energy savings
Lighting Ventilation and power conservation
equipment equipment
Infrared presence Note:
sensor information Adaptor for wiring: When the presence detection signal is output to external equipment using the adapter
KRP1C11A (Option) for wiring, other functions, such as interlock with the duct booster fan and the output
of other signals, become disabled.

Indoor units comply with D -Net standards *Except for FFF and FDF series

Previous indoor unit New indoor unit

Adaptor not
required
Optional
FHQ-BV interface adaptor
is required FHA-B

VRV
VRV

Easy connection to DIII-NET and long piping length makes this solution suitable for projects including and SkyAir.
18
Smart Airflow Control
Indoor units can provide 5-step and 3-step fine control of air volume
5-step: FCF and FHA series
3-step: FBA and FAA series

Comfort ensured by ‘Auto’


airflow rate that matches
load level
Convenient energy-efficiency for stores
with peak and quiet periods.

Level 1 (Low) Level 2 Level 3 (Medium) Level 4 Level 5 (High) Auto

Also convenient for high ceilings and spaces with long blow distances
*Field setting with remote controller
Cassette type <Round Flow>: Ceiling suspended type:
maximum 4.2 m* maximum 4.3 m

4.2 4.3
m m

See page 25 See page 36


*Maximum 4.2 m for FCF100, 125, 140
Maximum 3.5 m for FCF50, 60, 71

More Economy or Comfort in Special Situations


High sensible cooling enables High dehumidification cooling
even greater power savings provides even greater comfort
In locations such as In restaurants and other
simple server rooms, spaces where many people
dehumidification is not gather, ‘High
required and greater dehumidification cooling’
power savings are mode reduces humidity and
possible with 'High creates greater comfort.
sensible cooling' mode.

*Available with RZF100-140CVM4,


*Available with RZF-C series. 71-140CYM4 models.
Field setting with remote controller. Field setting on outdoor unit.

19
Detail of Each Product Specification

CEILING MOUNTED Page 21


FCF-C Series
CASSETTE TYPE

COMPACT MULTI FLOW


CEILING MOUNTED FFF-B Series Page 29
CASSETTE TYPE

CEILING MOUNTED FDF-B Series Page 31


SLIM DUCT TYPE

DUCT CONNECTION
MIDDLE STATIC FBA-B Series Page 33
PRESSURE TYPE

CEILING SUSPENDED TYPE FHA-B Series Page 35

WALL MOUNTED TYPE FAA-B Series Page 37

OUTDOOR UNIT RZF-C Series Page 39

REMOTE CONTROLLER Page 41

20
CEILING MOUNTED CASSETTE TYPE Round Flow

Cassette air conditioner with 360°


uniform airflow sets the standard
NEW
FCF/50/60/71/100/125/140CVM4

Option
Accessory required for indoor unit.

Navigation Remote Controller


(Wired Remote Controller)

NEW

BRC1E63
Note: Remote controller cable is not
included and must be obtained
locally.

Wireless LCD remote controller


A signal receiver must be added to the indoor unit.

NEW
Cooling only BRC7M635F
(Fresh white)
BRC7M635K
(Black)

Signal receiver unit


(Installed type)

Wireless remote controller is supplied in a


set with a signal receiver.

Panel variations

Standard panel with Standard panel


Sensing (Fresh white)
(Fresh white)

Designer panel
(Fresh white)

Standard panel with Standard panel


Sensing (Black)
(Black) Auto grille panel
(Fresh white)
21
1. See P. 3-6 for new functions of Round Flow Cassette.

Circulation Airflow
Cools the entire room to deliver comfort that never feels cold.

Cooling operation repeatedly performs the following at start.


2-way horizontal flow

4-way swing flow

2-way horizontal flow (direction changes)

4-way swing flow

Individual Airflow Direction Control 360° Airflow


Airflow direction can be individually adjusted for each air With uniform temperature distribution
discharge outlet to deliver optimal air distribution that
conforms to conditions for airflow direction (small and large
loads)
Selectable from position 0 to 4, swing, and no individual setting.
Airflow
distribution
creates uniform
Example comfort throughout
Position 0 No individual
the space.
(Fixed airflow to setting
highest position) (Auto airflow)
Room remains
comfortable even
when set temperature
Position 4 is raised 1℃.
Swing
(Up/down)
(Fixed airflow to the Greater comfort
lowest position)

Selectable Airflow Pattern


Because air flows out from corner outlets, comfort spreads more widely.

Typical flow patterns There are a total of 18 flow patterns.

L-shaped Opposite
All-round flow 3-way flow
2-way flow 2-way flow

(E.g., installed in (E.g., installed (E.g., installed in (E.g., installed in


middle of ceiling) near a wall) a corner) a long room)
4-way flow also possible.

Note:
- Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow,
Required * an air discharge outlet sealing material (option) must be used to close each unused outlet.
distance to Minimum distance
wall surface - Operation sound increases when using 2-way or 3-way flow.
of 500mm
for closing - Designer panel cannot operate 2-way and 3-way flow.
* 200mm for corner
air discharge * closing
outlet Wall surface

22
CEILING MOUNTED CASSETTE TYPE Round Flow

Daikin Sensing Technology*1,2 *1. Applicable when sensing panel (BYCQ125EEF/EEK) is installed.
*2. Applicable when wired remote controller BRC1E63 is used.

Dual Sensors*1
Dual sensors and individual airflow direction control automatically provide
optimal control of airflow.
Infrared presence sensor
The sensor detects the presence of people in each of the
4 areas.
Ceiling height 2.7m 3.5m 4.0m
Detection range approx. approx. approx.
(diameter)*3 8.5m 11.5m 13.5m
*3. The infrared presence sensor detects 80cm above the floor.

Detecting the
presence of people
Infrared floor sensor
in each of the 4 areas
The sensor detects the floor temperature and
automatically adjusts operation of the indoor unit to
reduce the temperature difference between the ceiling
C and the floor.
B D
Ceiling height 2.7m 3.5m 4.0m
A
Detection range approx. approx. approx.
(diameter)*4 11m 14m 16m
*4. The infrared floor sensor detects at the floor surface.
Detecting the
Standard range for infrared presence sensor *
average temperature
of the floor

2.7m
ceiling
height

80cm
above floor 約8.5m
approx.8.5m
*[Concerning infrared presence sensor]
- People are detected by large movements such as the motion of people walking at a
certain distance away from sensor.
- Human detection is not possible for blind areas of sensor.
[Concerning infrared floor sensor]
- The detected temperature may sometimes be affected by a heat source, window, or
device emitting heat in the detection range.

Auto Airflow Function*5 *5.Airflow direction should be set to “Auto”.

Direct Airflow (default: OFF) Cooling Dry


When human presence is not detected When human presence is detected

Optimal air direction Swing (narrow)


Optimal air direction by “Auto” by “Auto”

With “Auto” airflow direction mode, flaps are controlled When presence is detected, air direction is set
to deliver optimal airflow when the room is unoccupied. to “Swing (narrow)” to deliver cool air to users.

23
Comfort and Energy Saving Preventing Overcooling*6 *6.Airflow direction and airflow
rate should be set to “Auto”.

Floor temperature is detected and overcooling prevented. Cooling


Without sensing function With sensing function

30°C near ceiling 30°C near ceiling

Room 2 Room temperature is


temperature is calculated as 27°C in the area which
detected as is in the vicinity of the person.
30°C.

1 24°C near floor


20°C near floor

Area around feet gets too cold because the air The floor temperature, Automatic control using
conditioner continues until the temperature near the which is lower than the temperature near the
ceiling reaches the set temperature. near the ceiling, is person as the room
detected. temperature.

Energy The temperature near the person is automatically calculated by detecting the temperature of the
savings floor. Energy is saved because the area around the feet does not get too cold.

Sensing Sensor Functions*7,8,9 *7. Applicable when sensing panel (BYCQ125EEF/EEK) is installed.
*8. These functions are not available when using the group control system.
*9. User can set these functions with remote controller.

Sensing sensor low mode (default: OFF)


When there are no people in a room,
the set temperature is shifted automatically. Operation is
- The system automatically saves energy by detecting reduced in places
whether or not the room is occupied. The set temperature is where there are
shifted automatically if the room is unoccupied. no people.

• Cooling set temperature: 26°C • Shift temperature: 1.0°C


Example
• Shift time: 30 min. • Limit cooling set temperature: 30°C
Set temperature (°C)

*10
28 *10
28°C
27 27°C
26 26°C
26℃ 26°C
26℃ If people do not return,
Occupied Automatically reverts the air conditioner will
when people return. raise the set
Unoccupied temperature 1°C every
30 minutes and then
operate at 30°C.
Time
After 30 min After another 30 min

Shift temperature and time can be selected from 0.5 to 4°C in 0.5°C increments and 15, 30, 45, 60, 90 or 120 minutes respectively
with remote controller.

*10. On basic screen of remote controller, set temperature does not change.

Sensing sensor stop mode (default: OFF)


When there are no people in a room, the system stops automatically.*11,12
- The system automatically saves energy by
detecting whether or not the room is occupied.
- Based on preset user conditions, the system Absent stop time can be selected from
1 to 24 hrs in 1 hr increments with
automatically stops operation if the room is
remote controller.
unoccupied.
*11.Please note that upon re-entering the room,
the air conditioner will not switch on automatically.
*12.To protect the machine, the standby system may
operate temporarily.

24
CEILING MOUNTED CASSETTE TYPE Round Flow

Comfort
mm 95
Unified square panels 950 0m
m Same for
Panel size is the same for all models. all models
It is easy to maintain a neat appearance when multiple units are
installed in the same room.

Optimal comfort and convenience assured by 3 air discharge modes


Draft prevention setting Ceiling soiling prevention
Air direction Standard setting1 setting2 (field setting)
(field setting)

For shops with


Desired situation For gentle drafts. When drafts are unwanted. light coloured ceilings that
must be kept spotless.

Auto-swing
Note:
1
Air direction is set to the
standard position when the
5-level unit is shipped from the
air direction setting factory. The position can be
changed from the remote
controller.
The air direction is set automatically to the memorised 2
Closing of the corner
Auto air direction position of the previous air direction. discharge outlets is
control recommended.

Switchable fan speed: 5 steps and Auto Quiet operation dB(A)

Control of airflow rate has been improved from 3-step to 5-step. Indoor unit
Sound pressure level
Auto airflow rate is newly available. H HM M ML L
50-71C 37.0 34.5 32.0 29.5 27.5
100C 45.0 41.5 38.0 35.0 32.5

Suitable for high ceilings 125/140C 46.0 43.0 40.0 36.0 32.5

Even in spaces with high ceilings, a comfortable airflow is carried down to the floor level.
Standard Setting Setting Criteria for ceiling height and number of air discharge outlets
(Ceiling height is reference value)
Number of air discharge outlets used
50-71C 100–140C
3.6 4.2 All round 4-way 3-way 2-way All round 4-way 3-way 2-way
3.2 m flow flow flow flow flow flow flow flow
m m
Standard 2.7 m 3.1 m 3.0 m 3.5 m 3.2 m 3.4 m 3.6 m 4.2 m
Ceiling
High ceiling 3.0 m 3.4 m 3.3 m 3.8 m 3.6 m 3.9 m 4.0 m 4.2 m
height
High ceiling 3.5 m 4.0 m 3.5 m - 4.2 m 4.5 m 4.2 m -
Note:
When all round flow is selected, ceilings up to 4.2 m in height The aforementioned is for standard panels. See the installation manual for designer panels.
can be accommodated. (100-140C) Factory settings are for standard ceiling height and all-round flow.
High ceiling settings (1) and (2) are set with the remote controller by field setting.
High-efficiency filters are not available for high ceiling applications.

Humidity sensor
Not only temperature but also humidity is
detected, and adjustments are made for
comfortable air conditioning.

Cleanliness
Silver ion anti-bacterial drain pan Non-flocking flaps
A built-in antibacterial Flaps can be detached without use of tools.
treatment that uses silver Condensation does not easily
ion in the drain pan prevents form and dirt does not cling to
the growth of slime, non-flocking flaps.
bacteria, and mould that They are easy to clean.
cause odours and clogging.
(The lifespan of a silver ion
cartridge depends on the
Filter has anti-mould and
usage environment, but antibacterial treatment
should be changed once Prevents mould and microorganisms growing out of the
every two to three years.) dust and moisture that adheres to the filters.
25
Quick and Easy Installation Washer fixing plate
Washer

Lightweight Easy hanging


All models can be installed without using a lifter. Washer fixing plates secure washers
in place and prevent washers from
falling for easy installation.

Installable in tight ceiling spaces


Standard panel

256mm (50-71C) 261mm (50-71C) Easy removal of corner cover


298mm (100-140C) 303mm (100-140C) It is possible to easily
remove without use
of screws or tools.

Designer panel

256mm 261mm +42mm*1


298mm 303mm
42mm*1

*1.Body height (ceiling required space) is 42 mm higher than standard panel.

Auto grille panel

256mm 261mm +55mm*2


298mm 303mm
55mm*2

*2.Body height (ceiling required space) is 55 mm higher than standard panel.


*When the ceiling space is limited, an optional panel spacer is available.
(see P.28)

Easy height adjustment Ease in temporary hanging


Each corner of the unit has an
adjuster pocket that lets you
of decoration panel
easily adjust the unit's In addition to the temporary
suspended height. hanging fixtures in 2 places
normally used, corner part
Note: mounting fixtures in 4 places
If the wireless remote controller is installed,
a signal receiver unit is housed in one of are provided.
the adjuster pockets. Corner part mounting
fixtures (in 4 places) Temporary hanging
fixtures (in 2 places)

Temporary placement of control Drain pump


box lid Equipped as standard
accessory with
Because the control box lid can be temporarily hung 850 mm
850 mm lift.
on the unit, there is no need to climb down the
stepladder to retrieve it. 175 mm

Transparent drain socket

The detached lid can


be hung on a hook.
Hanging height adjustment
Because the configuration of the hanger bracket changed, the
Installed in any direction dimensions from the ceiling to the hanger bracket also change
during height adjustment for indoor unit.
Since the orientation of the A Dimensions
Hanger
suction grille can be bracket Standard panel 125-130mm
adjusted after installing, Designer panel 167-172mm
the direction of the suction A Auto grille panel 180-185mm
grille lines can be unified Chamber option*+ standard panel 175-180mm
Ceiling
when multiple units are surface *High-efficiency filter, ultra long-life filter, and
fresh air intake
installed.
26
CEILING MOUNTED CASSETTE TYPE Round Flow

Easy Maintenance
The condition of the drain pan and Auto grille panel (option)
drain water Grille and air filter cleaning can be performed without need for
Can be checked by removing the suction grille and a stepladder by lowering the grille.
drain plug.
A dedicated remote controller for the auto grille panel (BRC16A2)
Note: For inquiries concerning auto grille panel installations, please
contact your local dealer or Daikin representative. is included.
Operation is not possible using BRC1E63.

The drop length corresponds to


the ceiling height and can be set for
s t o pen lle! 8 different levels.
Drain outlet Ju ri
(with rubber plug)
u c t ion g
s Ceiling Height
Drop Length
Standard (m)
2.4 1.2
2.7 1.6
3.0 2.0
24 mm diameter drain outlet 3.5 2.4
The drain outlet allows 3.8 2.8
insertion of a finger or 4.2 3.1
dental mirror for inspection 4.5 3.5
of the internal cleanliness 5.0* 3.9
of the drain pan. Removal *Airflow range is up to 4.5m.
of the suction panel Please refer to “criteria for ceiling height
enables access. and number of air discharge outlets” on
page 25.

Ultra long-life filter (option)


See page 28

Maintenance is not required in normal shops or


offices for up to four years.

Low gas pressure detection

27
Options
Options required for specific operating environments

Ultra long-life filter unit Fresh air intake kit Note 1.2

Even in dusty environments where the air conditioning Using this kit, a duct can be connected to take in outdoor
is constantly operating, the ultra long-life filter only has air. There are two chamber types that have intake in two
to be cleaned once a year. places: with T-duct joint and without T-duct joint.
Filter chamber Outside
(Can be used with high-efficiency filter)

Ultra long-life filter

Dusty area: annual filter change


*For dust concentration of 0.3 mg/m3 (Requires separately sold Air purifier.)
1 year (Approx. 5,000 hr) 15 hr/day x 28 day/month x 12 month/year
The units can be installed in the following
Ordinary store or office: filter change every 4 years
different ways
*For dust concentration of 0.15 mg/m3
4 years (Approx. 10,000 hr) 8 hr/day x 25 day/month x 12 month/years Chamber type (without T-duct joint) Note 3.4.5
x 4 years
KDDP55B160
Flexible duct
High-efficiency filter unit (obtained locally)

T-duct joint
Available in two types: 65% and 90% colorimetry. (obtained locally)
Suction
Filter chamber chamber Intake duct
(obtained locally)
(Can be used with ultra long-life filter) (duct length: 4 m max.)
Connection
chamber

High-efficiency filter Chamber type (with T-duct joint) Note 3.4.5

KDDP55B160K

Insulation kit for high humidity Flexible duct

Please use if you think the temperature and humidity T-duct joint
inside the ceiling exceeds 30°C and RH 80%, Suction
Intake duct
respectively. chamber
(obtained locally)
Connection (duct length: 4 m max.)
Top panel insulation(1) chamber
Top panel insulation(2) Direct installation type Note 6
Top panel insulation(3)
KDDP55X160A
Insulation for decoration panel
Side panel insulation
Suspension bracket insulation

Panel spacer Duct flange


(with insulation material)
Use when only minimal space is available between Intake duct
(obtained locally)
drop ceilings and ceiling slabs.
Note: Some ceiling constructions may
hinder installation. Contact your
Note: 1. Use of options will increase operating sound.
Daikin Dealer before installing your
unit. 2. Connecting ducts, fan, insect nets, fire dampers, air filters, and other
40mm parts should, as required, be obtained locally.
Panel spacer 3. When a local-obtained fan is used, an interlock with air conditioner is
necessary.Optional PCB (KRP1C11A) is required for interlocking.
4. When installing a fresh air intake kit (chamber type), two air outlet
Sealing material of air discharge outlet corners are closed.
5. It is recommended that the volume of outdoor air introduced through
Sealing material block air discharge openings not used the kit is limited to 10% of the maximum airflow rate of the indoor
in 2-way or 3-way blow. unit. Introducing higher quantities will increase the operating sound
and may also influence temperature sensing.
6. The volume of fresh air for direct installation type is approximately
1% of the indoor unit airflow.
Branch duct The chamber type is recommended when more fresh air is
necessary.
(direct-connection round duct)
A round duct can be attached without the need for a
chamber.
A flanged port for direct connection of a round duct is
provided. An existing branch duct chamber can also be
fitted (square slit hole).

28
COMPACT MULTI FLOW
CEILING MOUNTED
CASSETTE TYPE

Quiet and decorative style that easily


installs in new or old buildings
NEW
FFF50/60BV14

Option
Accessory required for indoor unit.

Navigation Remote Controller


(Wired Remote Controller)

BRC1E62
Note: Remote controller cable is not
included and must be obtained
locally.

Wireless LCD remote controller


A signal receiver must be added to the indoor unit.

Cooling only BRC7E531W

Signal receiver unit


(Installed type)
Wireless remote
controller is supplied
in a set with a signal
receiver.

29
Compact Comfortable
Sized to fit inside 600mm wide Designed for low draft
ceiling grids performance 0 Horizontal flow 0

575 mm
Less draft
575 mm can be felt

286 tion
mm Decolrais also
pane act.
comp
Consistent comfort throughout
700 mm Auto-swing operation Airfow direction can be
distributes conditioned air adjusted in accordance with
more evenly. room conditions.
700 mm
Auto-swing 5-levels air direction setting

Standard 0 0
setting Auto-swing Settable to 5 different levels
Fits without the need to 60
between 0 and 60 60
between 0 and 60

cut T-bar grid Draft


prevention
The control box is built in to the unit, setting 0
Auto-swing
0
Settable to 5 different levels
so maintenance is possible (Set on site) 35 between 0 and 35 35 between 0 and 35
by simply removing the grille.
Setting to
An inspection opening is not required prevent soiling
even for modules other than of ceiling 25 Auto-swing 25 Settable to 5 different levels
between 25 and 60 between 25 and 60
600 mm x 600 mm. (Set on site) 60 60

Note: This angle above is provided as a guide.


Ceiling panel

T bar
Multi-Flow System Air direction can
600 mm
600 mm
4-way flow be selected
according to installation.
1 pattern

3-way flow

Quiet Operation 4 patterns

Quiet, but small-diameter fan


Quiet operation is achieved even with a compact 2-way flow
body and developed spiral hub cover that reduces 1 pattern
the static pressure inside the indoor unit.
" " denotes piping direction. Note: Operation sound increases
Drain piping " " denotes sealing when using 2-way or 3-way flow.
material for air discharge outlet (option) .
Note:
For 3-way or 2-way flow installation, the sealing
material for air discharge outlet (option) must be
used to close off the unused outlet(s).

Spiral hub cover Two selectable temperature-sensors


Both indoor unit and wired remote controllers contain temperature-sensors.
dB(A) Temperature sensing can be set at the unit or, to further improve comfort
Sound pressure level level, closer to the target area at the wired remote control.
Indoor unit
High Low This feature require initial setting by the installer.
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled from
50/60B 41 32 another room.
**Wireless remote controller does not have a temperature-sensor.

Switchable fan speed: High/Low


High setting provides maximum reach while low setting minimizes drafts.

Drain pump
750 mm
Equipped as standard accessory with
750 mm lift.

30
CEILING MOUNTED SLIM DUCT TYPE

Suitable for tight ceiling spaces


spaces.

NEW

FDF50/60BV14

Note: Refer to engineering data for airflow and external static


pressure characteristics.

Option
Accessory required for indoor unit.

Navigation Remote Controller


(Wired Remote Controller)

BRC1E62
Note: Remote controller cable is not
included and must be obtained
locally.

Standard

Wireless LCD remote controller


A signal receiver must be added to the indoor unit.

Cooling only BRC4C66

Signal receiver unit


(Separate type)

Wireless remote controller is supplied in a


set with a signal receiver.

31
Compact and Slim Design
Only 200 mm high
Easily installed in even shallow ceiling cavity with a
height of just 240 mm.
Indoor unit FDF50B FDF60B
200mm Height
Width
200 mm
1,100 mm
Depth 620 mm
620mm Weight 30 kg
1,100 mm

Bulkhead Installation
The slim duct type can be hidden inside the ceiling to provide a clean exterior. It is suitable for living rooms with shallow
tray ceilings or areas requiring a discreet appearance. FDF-B series are 900 and 1,100 mm wide, making them ideal for
narrow spaces.
All models are 200 mm high and require a space of only 240 mm between the drop ceiling and ceiling slab. With these
compact measurements, any unit can easily be installed in even shallow tray ceilings.

240 mm

Air inlet and suction grille


(parts obtained locally)
Air outlet

Smooth Finish Air discharge


Suspension bolt*
duct*
The only visible sign of these unobtrusive units is their Air filter
Air discharge
discharge grilles. grille*
They fit completely inside the ceiling to maintain the
original decor of a room.
AIR

Quiet Operation Chamber


dB(A) Signal receiver wire Air suction
Length = 1,900 mm grille*
Indoor unit
Sound pressure level
H L AIR
50/60B 38 34 *Locally obtained parts

Note:
1. To prevent an increase in operation sound, avoid installing the air suction grille
directly below the suction chamber.
2. Grilles, piping connections, ducts, and installation parts should be obtained
locally.
Duct-connected types do not have drain pumps.

32
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE

Thinner design allows greater


installation flexibility
NEW
FBA50/60/71/100/125/140BVM4

Option
Accessory required for indoor unit.

Navigation Remote Controller


(Wired Remote Controller)

BRC1E62
Note: Remote controller cable is not
included and must be obtained
locally.

Wireless LCD remote controller


A signal receiver must be added to the indoor unit.

Cooling only BRC4C66

Signal receiver unit


(Separate type)

Wireless remote controller is supplied in a


set with a signal receiver.

Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)
When air conditioning two rooms Door-installed Wall-installed
Under-door cutout
simultaneously, the air discharged into ventilation grille ventilation grille
each room must be circulated back to
the air conditioner. To achieve this, a
ventilation duct should be installed for Partitioning wall
Ventilates air through
the partitioning wall.
each room or one of the indicated (See right)
ventilation grilles should be installed Ventilation grille Ventilation grille Under-door cutout
on the partitioning wall or under the
Note: The under-door cutout method should be used only when there is a small volume of airflow.
door between the rooms.

33
Design and Installation Flexibility
Only 245 mm high Adjustable E.S.P.
Installation is possible even in buildings External static pressure can be controlled to within a
with narrow ceiling spaces. range of 50 Pa to 150 Pa by using a DC fan motor.

245mm 50 Pa 150 Pa
One of the industry’s most compact Set to low static Set to high static pressure for
bodies in the mid-static pressure range. pressure when ducts advanced needs such as when
are short. using dampers and long ducts.
Indoor unit 50/60/71B 100/125/140B
Comfort airflow is achieved in accordance with conditions
Height (mm) 245
such as duct length.
Width (mm) 1,000 1,400
Depth (mm) 800

Higher lift is realized Airflow rate auto adjustment function


Controls the airflow rate using a remote controller during
A built-in DC drain pump with standard accessory is utilised.
test run.
It is automatically adjusted to approximately ±10% of the
Middle & High static rated H tap airflow.
pressure type
850mm (FBQ-D series)

700mm Interlock control


As an energy saving
Bottom suction is available feature, the room air
conditioning unit can be
Wiring and servicing
interlocked with the hotel Interlock
can be done from the unit joist key card system.
underside of the unit
Using a 3rd-party building
(an option part Air suction management system, air
required). ceiling conditioning and lighting * Field setting with remote controller
can be interlocked.
Rear suction Bottom suction
Air suction flange Shield plate for side plate (option) DIII-NET communication standard
Connection to a centralised control system is available
without need for an optional adaptor.

Switch bottom plate with


Control box air suction flange.
cover Bottom Air suction
plate Make the control box
face inward.
flange
Bottom plate
Easy Maintenance
Position of drain pan inspection opening
Modified for easier inspection work.
Control box cover
Control box faces outward. Control box faces inward.
Drain pan maintenance check window
Comfort This makes it possible to inspect for drain pan dirt and to
confirm drainage during installation without the use of
tools.
Switchable fan speed: 3 steps and Auto

Clean
Inspection
opening for
drain pan
Drain pan

Silver ion anti-bacterial drain pan maintenance


check window

A built-in antibacterial treatment that uses silver ion in the


drain pan prevents the growth of slime, bacteria, and mould
that cause odours and clogging.
(The lifespan of a silver ion
High Efficiency
cartridge depends on the
usage environment, but DC fan motor and DC drain pump
should be changed once These are utilised to improve energy efficiency.
every two to three years.)
34
CEILING SUSPENDED TYPE

Comfortable airflow travels


throughout the room
NEW
FHA50/60/71/100/125/140BVM4

Option
Accessory required for indoor unit.

Navigation Remote Controller


(Wired Remote Controller)

NEW

BRC1E63
Note: Remote controller cable is not
included and must be obtained
locally.

Wireless LCD remote controller


A signal receiver must be added to the indoor unit.

NEW
Cooling only BRC7M56

Signal receiver unit (Installed type)


Wireless remote controller is supplied in
a set with a signal receiver.

35
Stylish Model Installation Flexibility for
Freedom of Design
Sophisticated design
Flap neatly closes when not in use.
Flexible
White colour installation 30 mm 30 mm
The unit fits more or more or more

*Water used in the test-run can be drained from


snugly into tight
Comfortable spaces.
the air discharge opening rather than from the
side as was formerly the case.

The technology of the DC fan motor, Drain pump kit (option)


wide sirocco fan, and large heat can be easily
exchanger combine for greater airflow incorporated 600
mm
and quiet operation Drain pipe connection can
be done inside the unit.
Auto swing (up and down) and louvers Refrigerant and drain pipe Drain pump kit
outlets are at the same
(left and right by hand) bring comfort opening.
(built inside
the unit)
to the room
DIII-NET communication standard
Louver manually adjusts for straight
Connection to a centralised control system is available
or wide angle airflow without need for an optional adaptor.

All wiring and internal servicing can


be done from under the unit

Easier piping work for


Suitable for high ceilings rear side by
removable frame
4.3
3.5 m
m
Easy Maintenance
50-71BVMA 100-140BVMA Drain pump kit (option) includes a
silver ion antibacterial agent
50-71B 100B 125/140B
That assists in preventing the growth of slime, bacteria,
Standard 2.7m or less 3.8m or less 4.3m or less and mould that cause odours and clogging.
High ceiling 2.7m-3.5m 3.8m-4.3m -
Note: Factory settings is “standard”.
“High ceiling” are set with remote controller by field setting. Non-flocking flap
Condensation does not easily
form and dirt does not cling to
non-flocking flap.
Switchable fan speed: 5 steps and Auto It is easy to clean. Non-flocking flap
Control of airflow rate has been improved from 3-step to 5-step.
Auto airflow rate is newly available.
Easy-clean, flat surfaces
Quiet Operation It is easy to wipe dirt off the flat side and lower surfaces
of the unit.
dB(A)
Sound pressure level
Indoor unit
H HM M ML L
50/60B 37.0 36.0 35.0 33.5 32.0 Oil Resistant Grille
71B 38.0 37.0 36.0 35.0 34.0
100B 42.0 40.0 38.0 36.0 34.0
Oil-resistant plastic is used for the
125B 44.0 42.5 41.0 39.0 37.0 air suction grille.
46.0 44.0 42.0 40.0 38.0 This satisfies durability in restaurants and other similar
140B
environments.
Note: Intended for use in salons, dining rooms, and ordinary sales floors, this
specification is not suitable for kitchens or other harsh environments.

36
WALL MOUNTED TYPE

Compact design and


easy installation
NEW
FAA100BVM4

Option
Accessory required for indoor unit.

Navigation Remote Controller


(Wired Remote Controller)

BRC1E62
Note: Remote controller cable is not
included and must be obtained
locally.

Wireless LCD remote controller


A signal receiver must be added to the indoor unit.

Cooling only BRC7EB519

Signal receiver unit (Installed type)


Wireless remote controller is supplied in a
set with a signal receiver.

37
Compact & Sophisticated Design Design and Installation Flexibility
FAA100 6-direction refrigerant
9kg lighter FAQ100BV FAA100B
Height 360mm 340mm
piping offers Left pipe

340
greater
Width 1,570mm 1,200mm
mm
installation
1,200mm Depth 200mm 240mm
flexibility Back-left pipe
370mm shorter Weight 26kg 17kg Bottom-left pipe

Back-right pipe
Right pipe
Bottom-right pipe

Flaps neatly close when


not in use Maintenance possible from the
Fresh white colour front of the unit
All maintenance tasks can be carried out via front
access. During servicing, attachment and detachment
Comfortable of parts is easier.

Auto swing (up and down) and wide-angle Drain pump kit is available as option
louvers (left and right by hand) Installs onto side of unit.

facilitate even room temperature Height of drain up

Refrigerant
piping
Wide-angle louvers (by hand) 1,000 mm
Soft material louver bends airflow over
a wider area
Indoor unit
Drain pump kit

Drain pump kit can be installed on


either left and right side of the indoor
An air discharge Auto-swing 5-level air direction setting
unit.
modes ensure
comfortable air
distribution across Adjustable to 5
Interlock control
the entire room different levels
As an energy saving feature, the room air
conditioning unit can be interlocked with the key card
system.

Comfort even on the far side of the room Using a 3rd-party building management system, air
conditioning and lighting can be interlocked.
To carry air to the far side of long
rooms, extra-high airflow adds 10% Lighting
more fan speed the "high" setting. Interlock
Air discharge strength is selected
from the remote controller by field
setting.
* Field setting with
remote controller
Switchable fan speed: 3 steps and Auto
DIII-NET communication
Programme "Dry" standard
Dehumidification is microprocessor controlled to prevent abrupt Connection to a centralised control system is
and uncomfortable changes in air temperature. available without need for an optional adaptor.

Easy Cleaning
Removable and Flat panel, easy to Non-flocking flaps
washable grille wipe dust off Condensation does not easily form
and dirt does not cling to non-flocking
flaps.
It is easy to clean.

38
OUTDOOR UNIT

Compact Outdoor Unit


NEW
NEW NEW
RZF125CVM4
RZF50CVM4 RZF71CYM4 RZF125CYM4
RZF60CVM4 RZF100CVM4 RZF140CVM4
RZF71CVM4 RZF100CYM4 RZF140CYM4

Easy Installation and Maintenance


4-direction piping offers greater layout Facilitates pump down (Refrigerant recovery function)
freedom (RZF125-140C) A pump-down switch is provided to make it easier to collect
The outer panel for the piping connection part of the front, refrigerant if the unit is to be moved or layout modified.
right side and backside can be removed and is easier for *Pump-down function is available for pre-charged refrigerant amount.
post-installation piping work. *Although pumping-down operation allows most of the refrigerant to be
recovered in a short period of time, some refrigerant will remain inside the
indoor unit and refrigerant piping.

Removable part of bottom


Using a refrigerant recovery machine, recover remaining refrigerant from
the stop valve service port until the pressure falls to 0.09 MPa. (gauge
pressure:-0.011MPa) or less.
frame makes the piping
work easier (RZF125-140C) Separation
Low gas pressure detection function
available
Effective gas monitoring reduces the labor required
for operation, maintenance, and repairs.

Reuse of Existing Piping: Refrigerant Pipe Size Table


Existing pipe size (Liquid / Gas) 6.4 / 6.4 / 9.5 / 9.5 / 9.5 / 12.7 / 12.7 / Level Design pressure The allowable minimum piping length is 5 m.
Outdoor Unit 12.7 15.9 12.7 15.9 19.1 15.9 19.1 difference (High pressure)
・Refer to the installation manual for details
Condition other than those mentioned in the left
RZF Max. table such as additional refrigerant charge
9.5 / 15.9 Max. piping length 10m 10m 50m 50m ------- 25m ------- 4.15MPa
50-71C 30m amount.
Chargeless pipng length 10m 10m 30m 30m ------- 15m ------- ・Clean the existing piping if its length
exceeds 30m.
Existing pipe size (Liquid / Gas) 6.4 / 6.4 / 9.5 / 9.5 / 9.5 / 12.7 / 12.7 / Level Design pressure ・Clean the existing piping if chargeless
Outdoor Unit 12.7 15.9 12.7 15.9 19.1 15.9 19.1 difference (High pressure) piping length exceeds limit of existing
Condition piping to perform pump-down refrigerant
RZF Max. recovery.
9.5 / 15.9 Max. piping length 10m 10m 50m 50m 50m 25m 25m 4.15MPa
100-140C 30m
Chargeless pipng length 10m 10m 30m 30m 30m 15m 15m

Standard pipe size Same condition with standard pipe Piping length and chargeless piping length are shortened
Piping length and chargeless piping length are much shortened Cooilng capacity is lowered (pay attention to piping length)
Reuse of existing piping is not allowed

Night Quiet Operation Mode


Peak outdoor temperature
The automatic night quiet mode will Sound pressure level1
Capacity (%)

(dB(A))
initiate 8 hours after the peak Cooling
only
Rated2 Night Quiet
100

temperature is reached in the daytime, Mode 8 hours


50 10 hours

and normal operation will resume 10 48


Load (%)

RZF50-71C 44
0

hours after that RZF100C 49 45 48


Sound (dB(A))

Rated
Operation

52 Quiet mode
Reducing noise will reduce capacity slightly. RZF125C 45 44 Quiet mode

Note : 1Anechoic chamber conversion value, measured according to JIS parameters RZF140C 54 45 8:00 12:00 16:00 20:00 0:00 4:00 8:00
and criteria. Note : Daikin date for RZF71C
Operating sound about 4 dB quieter
During operation these values are somewhat higher owing to ambient conditions.
2
Value when cooling. Value will differ when heating.

Demand Control Function


* Field setting
By setting limits that restrict power * Required for KRP58M51 (Option)
consumption, you can cut electricity bills Limitation
consumption

(RZF100-140CVM4, 71-140CYM4)
Power

Maximum power use is maintained within a set level of system


capacity. This enables effective demand control while
maintaining comfort. Maximum power consumption can be set
at 40, 60, 70, 80, or 100%. 8:00 12:00 16:00 20:00 Time
39
Technology for energy efficiency

The high efficiency compressor to


achieve a high COP 3

1 Compressor equiped with reluctance DC motor 2


Daikin DC Inverter models are equipped with the reluctance DC
motor for compressor.
The reluctance DC motor uses 2 different types of torque, neodymium 4
magnet*1 and reluctance torque*2. 1
This motor can save energy because it generates more power with a
smaller electric power than an AC or previous DC motor.

Reluctance
Reluctance DC Motor
DC motor Swing compressor
Motor efficiency

High efficiency during partial load


DC motor
operation.
More than 20%
Energy savings is realised,
AC motor eliminating the friction and the
leakage of refrigerant gas.
Swing bushing
Refrigerant gas
Rotational speed
Small load Large load
Low capacity High capacity
*1. A neodymium magnet is approximately 10
times stronger than a standard ferrite
Note: Data are based on studies conducted under magnet.
controlled conditions at a Daikin laboratory. *2. The torque created by the change in power
between the iron and magnet parts. Piston by incorporated
blade and roller.

2 Refrigerant cooling (RZF100-140CVM4, RZF71-140CYM4)

Daikin’s unique refrigerant cooling system exhibits


high cooling capacity even during high outdoor
temperatures.
Refrigerant cooling helps protect
the printed circuit board and
maintains high cooling capacity
even during high outdoor
temperatures.

3 High efficiency by micro channel heat exchanger Reduced wind resistance


The flattening of the heat exchanger tubes
improves the flow of air and increases heat
exchange efficiency.

Conventional tube and fin coil Micro channel coil Conventional heat Micro channel
exchanger heat exchanger
The diameter of the The diameter of the
refrigerant channel refrigerant channel
(holes where Flat, multi-hole (holes where refrigerant
refrigerant flows) is aluminium flows) is approx.1mm.
approx. 7mm heat exchanger
tubes

Approx. Approx.
7mm 1mm
Utilizing flat, multi-hole heat exchanger tubes increases
the heat exchange area and realizes energy savings.
Flow of refrigerant Flow of refrigerant

4 Fan
V-cut Propeller Fan (RZF50-100C)

Through use of a V-cut propeller fan that imitates the


efficiency of the swan, a migratory bird, airflow becomes
smooth and loss is reduced.
V-cut propeller fan Imitating the performance
Φ440 for RZF50-71CVM4 of the swan
Φ550 for RZF100CVM4,
RZF71-100CYM4

40
REMOTE CONTROLLER Optional accessory

Easy-to-read LCD remote controller allows various system


Remote controller options are shown on the page introducing each indoor unit model.

Navigation Remote Controller


(Wired LCD Remote Controller)

NEW
This simple, modern designed remote controller with
fresh white colour matches your interior design.
Operation is much easier and smoother, just follow
the indications on the navigation remote controller.

BRC1E63 BRC1E62

Energy saving
Setpoint auto reset Setpoint range set
- Even if the set temperature is changed, the new set temperature returns to the - Saves energy by limiting the
previous preset value after a preset duration of time. min. and max. set temperature.
- Period selectable from 30, 60, 90, or 120 min. - Avoids excessive heating or
Restaurant example cooling.
Restaurant opened Full tables at lunchtime After 30 minutes* - This function is convenient if
Temperature is set to 27ºC Then is lowered to 24ºC for Automatically returns to preset the remote controller is installed
crowded room temperature (27ºC) where anyone can change the
Returns to
settings.
27°C 24°C 27°C
automatically

*Preset-return time can be set

OFF timer (programmed)


at 30, 60, 90, or 120 min

- Sets and saves setting for an increment of time that automatically turns OFF air
conditioner after a preset period of time for each time operation starts.
- Period can be preset from 30 to 180 minutes in 10-minute increments.

Convenience
NEW 5-step airflow control (BRC1E63 only) Weekly schedule
- 5 actions per day can be scheduled
Energy consumption monitoring *1,2,3,4 for each day of the week.
- Past power consumption for the current and
- The holiday function will disable
previous days (2-hour intervals), week (1-day intervals),
schedule timer for the days that have
and year (1-month intervals) can be checked.
been set as holiday.
Note:
*1
Availability of this function may vary according to model (limited to partial - 3 independent schedules can be set.
functionality) (e.g. summer, winter, mid-season)
*2
Time setting is necessary. 
*3
This function cannot be used during group control. 
*4
This is a reference value for comparison and is not intended as a value for
investigation purposes in the calculation of electricity bills or contract for NEW Auto display off (BRC1E63 only)
electricity. Because it is a simple calculation of power consumption, there
are cases when the calculated value differs with the measurement results - While operation is stopping, LCD display can be turned OFF.
of a wattmeter. It will be displayed again if any button is pressed.
Setback (default: OFF) - Period can be preset from 10, 30, 60 minutes, and OFF.
Initial setting is 30 minutes.
- Maintains the room temperature in a specific range
during unoccupied periods by temporarily starting an
air conditioner that had been turned OFF.

41
control configurations and can control multiple indoor units.
Wireless LCD remote controller
The wireless remote controller is supplied in a set with a signal receiver.
NEW
Signal receiver unit of installed type is contained inside decoration panel
or indoor unit.
Shape of signal receiver unit differs according to the indoor unit.
Note: The signal receiver unit shown in the photograph is for mounting inside the decoration
panel of the ceiling mounted cassette type.

NEW Backlight LCD of new wireless remote controller

BRC7M635F
Signal receiver unit
(For ceiling mounted cassette type)

Pressing the backlight button helps


operating in dark rooms.

Wireless remote controller for each indoor unit type


Cooling only
BRC7M635F (Fresh white)
NEW CEILING MOUNTED CASSETTE TYPE
BRC7M635K (Black)
COMPACT MULTI FLOW TYPE BRC7E531W
CEILING MOUNTED SLIM DUCT TYPE BRC4C66
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE BRC4C66
NEW CEILING SUSPENDED TYPE BRC7M56
WALL MOUNTED TYPE BRC7EB519

Wired remote controller has built-in temperature-sensor


Enables temperature sensing closer to target area for improved comfort. (When using a remote control from another room,
temperature-sensor of the indoor unit air inlet must be selected.)

Facilitates maintenance and repair


All initial settings can be set from the remote controller. After interior construction is complete, ceiling mounted cassette type can
be remotely set without having to use a stepladder to access for manual setting.
Setting contents: High ceiling use, air direction, filter type, address for centralised control (group control address is set
automatically).

Remote controller is equipped with model name and failure display functions. This facilitates service in the unlikely event of a
malfunction.
(Model name display function applies to BRC1E62/63 only.)

SkyAir shares common control with Heat Reclaim Ventilator and the other Daikin air-conditioning
units, thus simplifying interlocking operations.
Easily adaptable to large-scale, high-function, centralised remote control systems.
Installing and connecting control wiring between SkyAir and other Daikin air-conditioning equipment is easy.

LCD panel shows operating status in letters, numbers, and motion.


Airflow / swing display Displays auto-swing operating status and setting position of air discharge angle.
Preset temperature / operation mode display Displays preset room temperature and operating status (fan, dry, cool).
Operation start and stop time can be set for individual timers up to 72 hours. The LCD also shows
Programming time display
when it is time to clean the filter, when changeover is under centralised control, and ventilation/cleaning.
Self-diagnosis function Monitors operating status within the system covering 40 items, and displays a message to indicate as soon as a malfunction occurs.

42
REMOTE CONTROLLER Optional accessory

System variation to control multiple indoor units


LCD REMOTE CONTROLLER
Control pattern Wired remote controller Wireless remote controller

Control by 1 (Basic system)


remote controller
Non-polar, double-core Signal receiver unit installed
(max. wiring length 500 m) on indoor unit

Control by 1 wireless remote


For control from 2 controller and 1 wired remote
Control by 2 locations such as in controller (See note 2)
remote controllers room and control room, Signal receiver unit installed
Connects 2 wired remote
exits, etc. on indoor unit
controllers (See note 1)

For simultaneous
Group control control of up to 16
indoor units. Automatic address setting function Automatic address setting function
Signal receiver unit installed
on 1 indoor unit

Operation and monitoring


Control by is carried out using the (Command from outside) (Command from outside)
contact signal from the
external command operation control box in
the monitoring room. Optional wiring adaptor for Optional wiring adaptor for
electrical appendices is necessary electrical appendices is necessary

Central remote controller (option) Central remote controller (option)

Centralised control of
Centralised remote up to 64 indoor groups
control from remote location
up to 1 km away.

Interface adapter for SkyAir series (option) is Interface adapter for SkyAir series (option) is
required (See note 3) required (See note 3)

Heat Reclaim Heat Reclaim


Ventilator Ventilator
Link by remote
controller group control.
Can be operated simultaneously Can be operated simultaneously
or independently by remote controller by remote controller
(set by ventilation mode)
Central remote controller (option) Central remote controller (option)
Interlock control
with Heat Reclaim
Ventilator
Zone link control by Heat Reclaim Heat Reclaim
Ventilator Ventilator
centralised control.
Heat Reclaim Ventilator for indoor units within
a zone is operated by interlocking. Heat Reclaim Ventilator for indoor units within a
Can also be operated independently by zone is operated by interlocking.
remote controller.

Note: 1BRC1E62 can connect to BRC1E62 only. BRC1E63 can connect BRC1E63 only. 2 When a wireless remote controller is used, it is not possible to use 2 wireless remote controllers.
Combination of BRC1E63 (main) and BRC7M (sub) is available. 3Compact multi flow cassette type (FFF) and Slim duct type (FDF) require interface adaptor for SkyAir series.

Easily adaptable to large-scale, high-function, centralised remote control system.


Central remote controller Unified on/off controller Schedule timer
DCS601C51 (Option)
DCS302CA61 (Option) DCS301BA61 (Option) DST301BA61 (Option)

Centralised control, with setting as Centralised control of on/off by Unified control of weekly schedule With its high functionality, the full
simple as it is with a standard group or all at once for up to 256 for up to 1,024 indoor units. colour “all-in-one” graphic controller
remote controller, of up to 64 groups indoor units. Schedule timer sets on/off time in 1 minute units facilitates management of SkyAir
(1,024 indoor units) is possible. to be executed twice a day for a week at a time. System in a variety of ways.

Interface adaptor for SkyAir series Enables centralised control via connection to a The interface adaptor for SkyAir series is required for
high-speed, DIII-NET communication system, Compact multi flow cassette type (FFF) and Slim duct
DTA112BA51 (Option) adopted for the Daikin   system. type (FDF).
Necessary for interface adaptor for SkyAir series with the central remote
control units shown at above.

43
Whatever your space, give it the comfort
it deserves

44
FUNCTIONS
CEILING MOUNTED COMPACT MULTI FLOW CEILING
CASSETTE TYPE Round Flow MOUNTED CASSETTE TYPE

Indoor unit FCF50-140CVM4 FFF50/60BV14


Cooling only Outdoor unit RZF50-140CVM4
RZF50/60CVM4
RZF71-140CYM4
Remote Wired BRC1E63 ------- BRC1E62 -------
controller Wireless ------- BRC7M635F (K) ------- BRC7E531W
1 Energy consumption monitoring *1
2 Sensing sensor stop mode *1 Sensing panel

3 Sensing sensor low mode *1, 2 Sensing panel

4 Auto display OFF *3


Energy
5 Setpoint auto reset *1
Saving
6 Setpoint range set *1
7 OFF timer (programmed) *1
8 Weekly schedule timer *1
9 ON/OFF timer

10 Circulation airflow *3
11 Setback *1
12 Quick start *1
13 Individual airflow control *1
14 Infrared presence sensor Sensing panel

15 Infrared floor sensor Sensing panel

16 Humidity sensor
17 Auto airflow function *3 Sensing panel
Comfort
18 Auto swing
19 Swing pattern selection
20 Switchable fan speed 5 step 5 step 2 step 2 step

21 Auto airflow rate


22 High fan speed mode
23 Two selectable temperature-sensors *1
24 High ceiling application 3.5m / 4.2m

25 Night quiet operation *4

26 Anti-bacterial air filter


27 Mould-proof air filter
Cleanliness
28 Silver ion anti-bacterial drain pan
29 Mould-proof drain pan

30 Auto grille panel


31 Drain pump mechanism
32 Pre-charged for up to 30 m *4
33 Long-life filter
Work &
34 Filter sign
Servicing
35 Low gas pressure detection *4
36 Emergency operation
37 Self-diagnosis function
38 Service contact display *1

39 Auto-restart
40 Control by 2 remote controllers *8

41 Group control by 1 remote controller


42 External equipment interlock *5 Sensing panel

Control 43 External signal forced OFF and ON/OFF operation


44 External command control *6
45 Central remote control *7

46 Interlock control with Heat Reclaim Ventilator


47 DIII-NET communication standard *7

48 High-efficiency filter
49 Ultra long-life filter
Options
50 Fresh air intake kit
51 Overvoltage PCB *4
Note: *1: Applicable when BRC1E62/63 is used *2: Not applicable when group control *3: Applicable when BRC1E63 is used
*6: Wiring adaptor for electrical appendices (and installation box) is necessary *7: Option is requied
45
CEILING MOUNTED DUCT CONNECTION MIDDLE CEILING SUSPENDED TYPE WALL MOUNTED TYPE
SLIM DUCT TYPE STATIC PRESSURE TYPE

FDF50/60BV14 FBA50-140BVM4 FHA50-140BVM4 FAA100BVM4


RZF50-140CVM4 RZF50-140CVM4 RZF100CVM4
RZF50/60CVM4
RZF71-100CYM4 RZF71-140CYM4 RZF100CYM4
BRC1E62 ------- BRC1E62 ------- BRC1E63 ------- BRC1E62 -------
------- BRC4C66 ------- BRC4C66 ------- BRC7M56 ------- BRC7EB519
1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18
19
20 2 step 2 step 3 step 3 step 5 step 5 step 3 step 3 step

21
22
23
24 3.5m / 4.3m

25

26 *7

27
28
29

30
31 *7 *7

32
33 *7

34
35
36
37
38

39
40 *8

41
42
43
44
45 *7

46
47 *7

48
49
50
51
*4: For outdoor units *5: Adaptor for Wiring (and installation box) is necessary
*8: It is not possible to use 2 wireless remote controllers. Combination of BRC1E63 (main) and BRC7M (sub) is available.
46
FUNCTIONS

Abundance of functions that provide comfortable


air-conditioning in stores and offices
Note: Some features are only available on selected models. See overview pages for full list of features applicable to each unit.

Energy Saving
1. Energy consumption monitoring 6. Setpoint range set
Past power consumption is displayed for the current and previous Saves energy by limiting the minimum and maximum set temperatures.
days as well as in weekly and yearly intervals. Avoids excessive heating and cooling.

2. Sensing sensor stop mode 7. OFF timer (programmed)


When the room is unoccupied, the system stops automatically. Sets and saves setting for an increment of time that automatically
turns off air conditioner after a preset period of time for each time
3. Sensing sensor low mode operation starts.
When the room is unoccupied, the set temperature is shifted
automatically. 8. Weekly schedule timer
Up to five operation ON/OFF settings can be programmed per day for
each day of the week. Not only can the time be set for the operation
4. Auto display OFF ON setting, but also the temperature.
While operation is stopping, the LCD display can be turned off. 
It can be displayed again when any button is pressed.
9. ON/OFF timer
Operation starts when the preset time of the ON timer elapses and
5. Setpoint auto reset stops when the preset time of the OFF timer elapses.
Even if the set temperature is changed, the new set temperature
returns to the previous preset value after a preset duration of time.

Comfort
10. Circulation airflow 19. Swing pattern selection
At the start of operation, airflow changes repeatedly between You can freely set air discharge settings by remote controller.
horizontal flow and downward flow (swing during cool operation), (1) Standard (2) Draft prevention (3) Ceiling soiling
and air is sent throughout the room to eliminate uneven setting setting prevention setting
temperatures.

11. Setback
Maintains the room temperature in a specific range during
unoccupied periods by temporarily starting an air conditioner that
had been turned OFF. 20. Switchable fan speed
High setting provides maximum reach while low setting minimises drafts.
12. Quick start
At operation start, capacity priority operation is possible. 21. Auto airflow rate
Airflow rate is automatically controlled in accordance with the
13. Individual airflow control difference between room temperature and set temperature.
Airflow direction can be individually adjusted for each air
discharge outlet to deliver optimal air distribution. 22. High fan speed mode
You can increase fan speed approximately 10% higher than the
14. Infrared presence sensor "high" setting.
The sensor detects the presence of people in each of the 4 areas.

23. Two selectable temperature-sensors


15. Infrared floor sensor Temperature-sensors are included in
The sensor detects the floor temperature and automatically the indoor unit and optional wired
adjusts operation of the indoor unit to reduce the temperature remote controller. Temperature sensing
difference between the ceiling and the floor. closer to target area is possible to
further increase the comfort level.
16. Humidity sensor Use the temperature-sensor in the indoor unit when
controlling air conditioning from another room.
Not only temperature but also humidity is detected, and Note: Wireless remote controllers have no temperature-sensor.
adjustments are made for comfortable air conditioning.

17. Auto airflow function 24. High ceiling application


Delivers air-conditioning comfort
When this function is set, airflow direction can be directed toward
all the way down to the floor in
or away from people when human presence is detected.
air-conditioning zones with high
ceilings.
18. Auto swing Note:When units are installed on high ceilings, depending on the model,
Delivers comfortable air-conditioning to all areas, near to and far various restrictions concerning maximum height, air discharge direction,
from the air-conditioner. and choice of options may apply.
The air flow direction can be fixed at your desired angle by the
remote controller. 25. Night quiet operation
The Automatic night quiet mode will initiate 8 hours after the peak
temperature is reached in the daytime, and normal operation will
resume 10 hours after that.

47
Cleanliness
26. Anti-bacterial air filter 28. Silver ion anti-bacterial drain pan
The air filter has an anti-bacterial treatment to help prevent the A built-in antibacterial treatment that uses silver ion in the drain pan
growth of bacteria and mould on it. prevents the growth of slime, bacteria, and mould that cause odours
and clogging.
27. Mould-proof air filter
Sanitary filter has mould-resistant treatment. 29. Mould-proof drain pan
Mould-proof drain pan prevents growth of mould in highly humid
conditions.

Work & Servicing


30. Auto grille panel 35. Low gas pressure detection
Grille and air filter cleaning can be performed without need for Insufficient gas charging is normally hard to detect. During test run
a stepladder by lowering the grille. after installation and regular inspection, the refrigerant level is
monitored by a microprocessor to maintain proper gas pressure.
31. Drain pump mechanism Reliability is assured and maintenance and inspection can be carried
Steeper gradient realises more efficient out more quickly.
condensate drainage. High-lift is especially
useful for long lengths of drain piping.
36. Emergency operation
32. Pre-charged for up to 30 m Even if there is a malfunction elsewhere in the system, the fan or
compressor can still be operated. (depending on the malfunction)
If refrigerant piping length does not exceed 30 m, there is no
need for on-site gas charging.
37. Self-diagnosis function
33. Long-life filter The operating parameters of indoor and outdoor units, and sensor
Maintenance is not required for one year*. data at critical locations throughout the system, are constantly
The filter is washable and can be reused. monitored using a microcomputer. To facilitate quick response in the
*For dust concentration of 0.15 mg/m3 event of a malfunction, a message appears on the LCD of the remote
controller and an LED on the unit illuminates.
34. Filter sign
The filter sign warns you when it is time to clean the filter.
*When using a wired remote controller the sign is displayed in the LCD.
38. Service contact display
When using a wireless remote controller the filter sign lamp illuminates When installing the unit, registration of the service contact is available
on the signal receiver unit. to the wired remote controller.

Control
39. Auto-restart 43. External signal forced OFF and ON/OFF operation
If there is a power outage while the equipment is operating, The air conditioner can be interlocked with the keycard system and
operations will restart in the same mode as before the power turned ON/OFF by locking and unlocking the room.
cut when electricity is restored. The air conditioner can be also be turned OFF by the interlock with
the ventilation and lighting OFF signal.
40. Control by 2 remote controllers *Field setting with remote controller.
Using 2 remote controllers you can operate the equipment
locally or from a remote location. 44. External command control
*When a wireless remote controller is used, it is not possible to use 2 Operation and monitoring is carried out using the contact signal from
wireless remote controllers. the operation control box in the building monitoring room.
Combination of BRC1E63 (main) and BRC7M (sub) is available.
*Wiring adaptor for electrical appendices (and installation box) is necessary.
41. Group control by 1 remote controller
You can turn up to 16 indoor units ON/OFF with a single 45. Central remote control
remote controller. (When using connected indoor units, the Optional central remote controller enables centralised control of up to
settings must all be the same and on/off will be simultaneous.) 1024 indoor units (64 groups) from up to 1 km away.

42. External equipment interlock 46. Interlock control with Heat Reclaim Ventilator
Human presence is detected by the built-in infrared presence
Enables interlocking control with external equipment such as Heat
sensor in the sensing panel, and the presence detection
Reclaim Ventilator.
signal can be output and interlocked with external equipment.
Power conservation is possible though the interlock of
external equipment, such as lighting, with the infrared 47. DIII-NET communication standard
presence sensor. Connection to a centralised control system is available
*Adaptor for Wiring (and installation box) is necessary. without need for an optional adaptor.

Options
48. High-efficiency filter 50. Fresh air intake kit
Two types are available: 65% and 90% colorimetry. You can provide air-conditioning with fresh air from outside.
Convenient for places where a ventilation fan cannot be installed.
49. Ultra long-life filter
Requires no maintenance for about 4 years* (10,000h) in
51. Overvoltage PCB
stores and offices. Optional circuit eliminates the need for a stabiliser and offer additional
protection for devices in the outdoor unit, such as its fan motor and
*For dust concentration of 0.15 mg/m 3
compressor.

48
SPECIFICATIONS

CEILING MOUNTED CASSETTE TYPE < Round Flow > ( 1 Phase )


50 60 71 100 125 140
Indoor unit FCF50CVM4 FCF60CVM4 FCF71CVM4 FCF100CVM4 FCF125CVM4 FCF140CVM4
Model
Name Outdoor unit RZF50CVM4 RZF60CVM4 RZF71CVM4 RZF100CVM4 RZF125CVM4 RZF140CVM4
Power supply Outdoor unit 1 Phase, 220–240V / 220-230V, 50Hz / 60Hz
Cooling Capacity 1,2 5.0 6.0 7.1 10.0 12.5 14.0
Rated (Min. - Max.) kW (3.2-5.6) (3.2-6.0) (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.5)
17,100 20,500 24,200 34,100 42,700 47,800
Btu/h (10,900-19,100) (10,900-20,500) (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,900)
Power consumption Cooling kW 1.14 1.53 1.93 2.97 4.18 5.47
COP W/W 4.39 3.92 3.68 3.37 2.99 2.56
CSPF Wh/Wh 6.60 6.31 6.17 5.50 5.15 5.00
Indoor unit Colour Unit ----------
Decoration panel Fresh white
Airflow rate m3/min 23.0 / 21.0 / 18.5 / 16.0 / 13.5 34.5 / 31.0 / 27.5 / 24.0 / 20.0 36.5 / 33.0 / 29.0 / 25.0 / 21.0
(H / HM / M / ML / L) cfm 812 / 741 / 653 / 565 / 477 1,218 / 1,094 / 971 / 847 / 706 1,288 / 1,165 / 1,024 / 883 / 741
Sound pressure level 3 (H / HM / M / ML / L) dB(A) 37.0 / 34.5 / 32.0 / 29.5 / 27.5 45.0 / 41.5 / 38.0 / 35.0 / 32.5 46.0 / 43.0 / 40.0 / 36.0 / 32.5
Dimensions Unit mm 256X840X840 298X840X840
(HXWXD) Decoration panel mm 50X950X950
Machine Unit kg 22 24
weight Decoration panel kg 5.5
Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white
unit Coil Type Micro channel
Compressor Type Hermetically sealed swing type
Motor output kW 1.30 1.60 2.40
Refrigerant charge (R32) kg 1.2(Charged for 30 m) 1.3(Charged for 30 m) 1.9(Charged for 30 m)
Sound Cooling dB(A) 48 49 52 54
pressure level 3 Night quiet mode dB(A) 44 45
Dimensions (HXWXD) mm 595X845X300 695X930X350 990X940X320
Machine weight kg 41 48 64
Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm 9.5
connections Gas (Flare) mm 15.9
Drain Indoor unit mm VP25 (I.D. 25XO.D. 32)
Outdoor unit mm 26.0 (Hole) 18.0 (Hole) 26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
Heat insulation Both liquid and gas piping

CEILING MOUNTED CASSETTE TYPE < Round Flow > ( 3 Phase )


71 100 125 140
Indoor unit FCF71CVM4 FCF100CVM4 FCF125CVM4 FCF140CVM4
Model
Name Outdoor unit RZF71CYM4 RZF100CYM4 RZF125CYM4 RZF140CYM4
Power supply Outdoor unit 3 Phase, 380–415V / 380V, 50Hz / 60Hz
Cooling Capacity 1,2 7.1 10.0 12.5 14.0
Rated (Min. - Max.) kW (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.5)
24,200 34,100 42,700 47,800
Btu/h (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,900)
Power consumption Cooling kW 1.93 2.97 4.18 5.47
COP W/W 3.68 3.37 2.99 2.56
CSPF Wh/Wh 6.17 5.50 5.15 5.00
Indoor unit Colour Unit ----------
Decoration panel Fresh white
Airflow rate m3/min 23.0 / 21.0 / 18.5 / 16.0 / 13.5 34.5 / 31.0 / 27.5 / 24.0 / 20.0 36.5 / 33.0 / 29.0 / 25.0 / 21.0
(H / HM / M / ML / L) cfm 812 / 741 / 653 / 565 / 477 1,218 / 1,094 / 971 / 847 / 706 1,288 / 1,165 / 1,024 / 883 / 741
Sound pressure level 3 (H / HM / M / ML / L) dB(A) 37.0 / 34.5 / 32.0 / 29.5 / 27.5 45.0 / 41.5 / 38.0 / 35.0 / 32.5 46.0 / 43.0 / 40.0 / 36.0 / 32.5
Dimensions Unit mm 256X840X840 298X840X840
(HXWXD) Decoration panel mm 50X950X950
Machine Unit kg 22 24
weight Decoration panel kg 5.5
Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white
unit Coil Type Micro channel
Compressor Type Hermetically sealed swing type
Motor output kW 1.60 2.40
Refrigerant charge (R32) kg 1.3(Charged for 30 m) 1.9(Charged for 30 m)
Sound Cooling dB(A) 48 49 52 54
pressure level 3
Night quiet mode dB(A) 44 45
Dimensions (HXWXD) mm 695X930X350 990X940X320
Machine weight kg 48 64
Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm 9.5
connections Gas (Flare) mm 15.9
Drain Indoor unit mm VP25 (I.D. 25XO.D. 32)
Outdoor unit mm 18.0 (Hole) 26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
Heat insulation Both liquid and gas piping
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.

49
(H) 16 / (L) 13.5 (H) 16 / (L) 13.5

200 x 1100 x 620 200 x 1100 x 620


SPECIFICATIONS

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE ( 1 Phase )


50 60 71 100 125 140
Indoor unit FBA50BVM4 FBA60BVM4 FBA71BVM4 FBA100BVM4 FBA125BVM4 FBA140BVM4
Model
Name Outdoor unit RZF50CVM4 RZF60CVM4 RZF71CVM4 RZF100CVM4 RZF125CVM4 RZF140CVM4
Power supply Indoor unit 1 Phase, 220–240V / 220-230V, 50Hz / 60Hz
Outdoor unit 1 Phase, 220–240V / 220-230V, 50Hz / 60Hz
Cooling Capacity 1,2 5.0 6.0 7.1 10.0 12.5 14.0
Rated (Min. - Max.) kW (3.2-5.6) (3.2-6.0) (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.5)
17,100 20,500 24,200 34,100 42,700 47,800
Btu/h (10,900-19,100) (10,900-20,500) (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,900)
Power consumption Cooling kW 1.35 1.64 2.15 3.01 4.44 5.69
COP W/W 3.70 3.66 3.30 3.32 2.82 2.46
CSPF Wh/Wh 5.51 5.30 5.19 4.88 4.70 4.47
Indoor unit Colour ----------
Fan Airflow rate (H/M/L) m3/min 18.0 / 15.0 / 12.5 23.0 / 19.5 / 16.0 32.0 / 27.0 / 22.5 36.0 / 30.5 / 25.0
cfm 635 / 530 / 441 812 / 688 / 565 1,130 / 953 / 794 1,271 / 1,077 / 883
External static pressure 3 Pa Rated 50 (50-150)
Sound pressure level 4 (H/M/L) dB(A) 35.0 / 33.0 / 31.0 38.0 / 35.0 / 33.0 40.0 / 37.5 / 35.0
Air filter 5 ----------
Dimensions (HXWXD) mm 245X1000X800 245X1400X800
Machine weight kg 37 47
Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white
unit Coil Type Micro channel
Compressor Type Hermetically sealed swing type
Motor output kW 1.30 16.0 2.40
Refrigerant charge (R32) kg 1.2(Charged for 30 m) 1.3(Charged for 30 m) 1.9(Charged for 30 m)
Sound Cooling dB(A) 48 49 52 54
pressure level 4
Night quiet mode dB(A) 44 45
Dimensions (HXWXD) mm 595X845X300 695X930X350 990X940X320
Machine weight kg 41 48 64
Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm 9.5
connections Gas (Flare) mm 15.9
Drain Indoor unit mm VP25 (I.D. 25XO.D. 32)
Outdoor unit mm 26.0 (Hole) 18.0 (Hole) 26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
Heat insulation Both liquid and gas piping

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE ( 3 Phase )


71 100 125 140
Indoor unit FBA71BVM4 FBA100BVM4 FBA125BVM4 FBA140BVM4
Model
Name Outdoor unit RZF71CYM4 RZF100CYM4 RZF125CYM4 RZF140CYM4
Power supply Indoor unit 1 Phase, 220–240V / 220-230V, 50Hz / 60Hz
Outdoor unit 3 Phase, 380–415V / 380V, 50Hz / 60Hz
Cooling Capacity 1,2 7.1 10.0 12.5 14.0
Rated (Min. - Max.) kW (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.5)
24,200 34,100 42,700 47,800
Btu/h (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,900)
Power consumption Cooling kW 2.15 3.01 4.44 5.69
COP W/W 3.30 3.32 2.82 2.46
CSPF Wh/Wh 5.19 4.88 4.70 4.47
Indoor unit Colour ----------
Fan Airflow rate (H/M/L) m3/min 23.0 / 19.5 / 16.0 32.0 / 27.0 / 22.5 36.0 / 30.5 / 25.0
cfm 812 / 688 / 565 1,130 / 953 / 794 1,271 / 1,077 / 883
External static pressure 3 Pa Rated 50 (50-150)
Sound pressure level 4 (H/M/L) dB(A) 38.0 / 35.0 / 33.0 40.0 / 37.5 / 35.0
Air filter 5 ----------
Dimensions (HXWXD) mm 245X1000X800 245X1400X800
Machine weight kg 37 47
Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white
unit Coil Type Micro channel
Compressor Type Hermetically sealed swing type
Motor output kW 1.60 2.40
Refrigerant charge (R32) kg 1.3(Charged for 30 m) 1.9(Charged for 30 m)
Sound Cooling dB(A) 48 49 52 54
pressure level 4
Night quiet mode dB(A) 44 45
Dimensions (HXWXD) mm 695X930X350 990X940X320
Machine weight kg 48 64
Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm 9.5
connections Gas (Flare) mm 15.9
Drain Indoor unit mm VP25 (I.D. 25XO.D. 32)
Outdoor unit mm 18.0 (Hole) 26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
Heat insulation Both liquid and gas piping
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
External static pressure is changeable in 11 stages by remote controller.
4
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
5
Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency (gravity method) 50% or more.

51
CEILING SUSPENDED TYPE ( 1 Phase )
50 60 71 100 125 140
Indoor unit FHA50BVM4 FHA60BVM4 FHA71BVM4 FHA100BVM4 FHA125BVM4 FHA140BVM4
Model
Name Outdoor unit RZF50CVM4 RZF60CVM4 RZF71CVM4 RZF100CVM4 RZF125CVM4 RZF140CVM4
Power supply Outdoor unit 1 Phase, 220–240V / 220-230V, 50Hz / 60Hz
Cooling Capacity 1,2 5.0 6.0 7.1 10.0 12.5 14.0
Rated (Min. - Max.) kW (3.2-5.5) (3.2-6.0) (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.5)
17,100 20,500 24,200 34,100 42,700 47,800
Btu/h (10,900-19,100) (10,900-20,500) (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,900)
Power consumption Cooling kW 1.20 1.53 2.30 3.24 4.29 5.40
COP W/W 4.17 3.92 3.09 3.09 2.91 2.59
CSPF Wh/Wh 6.30 6.11 5.91 5.17 5.09 4.78
Indoor unit Colour White
Airflow rate m3/min 15.0 / 13.5 / 12.0 / 11.0 / 10.0 20.5 / 18.8 / 17.0 / 15.5 / 14.0 28.0 / 26.0 / 24.0 / 22.0 / 20.0 31.0 / 29.0 / 27.0 / 25.0 / 23.0 34.0 / 31.5 / 29.0 / 26.5 / 24.0
(H / HM / M / ML / L) cfm 530 / 477 / 424 / 388 / 353 724 / 664 / 600 / 547 / 494 988 / 918 / 847 / 777 / 706 1,094 / 1,024 / 953 / 883 / 812 1,200 / 1,112 / 1,024 / 935 / 847
Sound pressure level 3 (H / HM / M / ML / L) dB(A) 37.0 / 36.0 / 35.0 / 33.5 / 32.0 38.0 / 37.0 / 36.0 / 35.0 / 34.0 42.0 / 40.0 / 38.0 / 36.0 / 34.0 44.0 / 42.5 / 41.0 / 39.0 / 37.0 46.0 / 44.0 / 42.0 / 40.0 / 38.0
Dimensions (HXWXD) mm 235X960X690 235X1270X690 235X1590X690
Machine weight kg 25 32 38
Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white
unit Coil Type Micro channel
Compressor Type Hermetically sealed swing type
Motor output kW 1.30 1.60 2.40
Refrigerant charge (R32) kg 1.2(Charged for 30 m) 1.3(Charged for 30 m) 1.9(Charged for 30 m)
Sound Cooling dB(A) 48 49 52 54
pressure level 3
Night quiet mode dB(A) 44 45
Dimensions (HXWXD) mm 595X845X300 695X930X350 990X940X320
Machine weight kg 41 48 64
Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm 9.5
connections Gas (Flare) mm 15.9
Drain Indoor unit mm VP20 (I.D. 20XO.D. 26)
Outdoor unit mm 26.0 (Hole) 18.0 (Hole) 26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
Heat insulation Both liquid and gas piping

CEILING SUSPENDED TYPE ( 3 Phase )


71 100 125 140
Indoor unit FHA71BVM4 FHA100BVM4 FHA125BVM4 FHA140BVM4
Model
Name Outdoor unit RZF71CYM4 RZF100CYM4 RZF125CYM4 RZF140CYM4
Power supply Outdoor unit 3 Phase, 380–415V / 380V, 50Hz / 60Hz
Cooling Capacity 1,2 7.1 10.0 12.5 14.0
Rated (Min. - Max.) kW (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.5)
24,200 34,100 42,700 47,800
Btu/h (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,900)
Power consumption Cooling kW 2.30 3.24 4.29 5.40
COP W/W 3.09 3.09 2.91 2.59
CSPF Wh/Wh 5.91 5.17 5.09 4.78
Indoor unit Colour White
Airflow rate m3/min 20.5 / 18.8 / 17.0 / 15.5 / 14.0 28.0 / 26.0 / 24.0 / 22.0 / 20.0 31.0 / 29.0 / 27.0 / 25.0 / 23.0 34.0 / 31.5 / 29.0 / 26.5 / 24.0
(H / HM / M / ML / L) cfm 724 / 664 / 600 / 547 / 494 988 / 918 / 847 / 777 / 706 1,094 / 1,024 / 953 / 883 / 812 1,200 / 1,112 / 1,024 / 935 / 847
Sound pressure level 3 (H / HM / M / ML / L) dB(A) 38.0 / 37.0 / 36.0 / 35.0 / 34.0 42.0 / 40.0 / 38.0 / 36.0 / 34.0 44.0 / 42.5 / 41.0 / 39.0 / 37.0 46.0 / 44.0 / 42.0 / 40.0 / 38.0
Dimensions (HXWXD) mm 235X1270X690 235X1590X690
Machine weight kg 32 38
Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white
unit Coil Type Micro channel
Compressor Type Hermetically sealed swing type
Motor output kW 1.60 2.40
Refrigerant charge (R32) kg 1.3(Charged for 30 m) 1.9(Charged for 30 m)
Sound Cooling dB(A) 48 49 52 54
pressure level 3
Night quiet mode dB(A) 44 45
Dimensions (HXWXD) mm 695X930X350 990X940X320
Machine weight kg 48 64
Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm 9.5
connections Gas (Flare) mm 15.9
Drain Indoor unit mm VP20 (I.D. 20XO.D. 26)
Outdoor unit mm 18.0 (Hole) 26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
Heat insulation Both liquid and gas piping

Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.

52
SPECIFICATIONS

WALL MOUNTED TYPE ( 1 Phase, 3 Phase )


100
Indoor unit FAA100BVM4
Model
Name Outdoor unit RZF100CVM4 RZF100CYM4
Power supply Outdoor unit 1 Phase, 220–240V / 220-230V, 50Hz / 60Hz 3 Phase, 380-415V / 380V, 50Hz / 60Hz
Cooling Capacity 1,2 10.0
Rated (Min. - Max.) kW (5.0-11.2)
34,100
Btu/h (17,100-38,200)
Power consumption Cooling kW 3.60
COP W/W 2.78
CSPF Wh/Wh 4.05
Indoor unit Colour Fresh white
Airflow rate (H/M/L) m3/min 26.0 / 23.0 / 19.0
cfm 918 / 812 / 671
Sound pressure level 3 (H/M/L) dB(A) 49 / 45 / 41
Dimensions (HXWXD) mm 340X1200X240
Machine weight kg 17
Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white
unit Coil Type Miclo channel
Compressor Type Hermetically sealed swing type
Motor output kW 1.60
Refrigerant charge (R32) kg 1.3 (Charged for 30 m)
Sound Cooling dB(A) 49
pressure level 3
Night quiet mode dB(A) 45
Dimensions (HXWXD) mm 695X930X350
Machine weight kg 48
Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm 9.5
connections Gas (Flare) mm 15.9
Drain Indoor unit mm VP13 (I.D. 13XO.D. 18)
Outdoor unit mm 18.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
Heat insulation Both liquid and gas piping
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.

53
OPTIONS

Indoor unit
CEILING MOUNTED CASSETTE TYPE < Round Flow >
Kit name
Name of option Remark
FCF50CVM4 FCF60CVM4 FCF71CVM4 FCF100CVM4 FCF125CVM4 FCF140CVM4
Standard panel with Fresh white BYCQ125EEF
Sensing Black BYCQ125EEK
Decoration Fresh white BYCQ125EAF
1 panel Standard panel
Black BYCQ125EAK
Designer panel 1 Fresh white BYCQ125EAPF
Auto grille panel 2,3 Fresh white BYCQ125EASF
Sealing material of air discharge outlet 4 1 Outlet KDBH551C160
2
2 Outlet KDBH552C160
3 Panel spacer KDBP55H160FA
Fresh air intake kit Chamber Without T-duct joint KDDP55B160 (Components: KDDP55C160-1, KDDP55B160-2) 8
4 type 5,6 With T-duct joint KDDP55B160K (Components: KDDP55C160-1, KDDP55B160K2) 8
Direct installation type 7 KDDP55X160A
High-efficiency filter unit 9 (Colorimetric method 65%) KAFP556C80 KAFP556C160
5 (Including filter chamber) (Colorimetric method 90%) KAFP557C80 KAFP557C160
Replacement high-efficiency filter 9,10 (Colorimetric method 65%) KAFP552B80 KAFP552B160
6
(Colorimetric method 90%) KAFP553B80 KAFP553B160
7 Filter chamber KDDFP55C160
8 Replacement long-life filter KAFP551K160
9 Replacement long-life filter (Auto grille panel) KAFP551H161
10 Ultra long-life filter unit (Including filter chamber) 9 KAFP55C160
11 Replacement ultra long-life filter 9,10 KAFP55H160H
12 Branch duct chamber 4 KDJP55C80 KDJP55C160
13 Insulation kit for high humidity 9,11 KDTP55K80 KDTP55K160
14 Remote controller Wireless type Cooling only BRC7M635F (Fresh white) / BRC7M635K (Black)
15 Navigation remote controller Wired type 12 BRC1E63
16 Central remote controller 13 DCS302CA61
17 Unified ON/OFF controller 13 DCS301BA61
18 Schedule timer 13 DST301BA61
19 Intelligent Touch Controller 13 DCS601C51
22 Adaptor for wiring 14 KRP1C11A
23 Wiring adaptor for electrical appendices 14 KRP4AA53
24 Installation box for adaptor PCB KRP1H98A
25 Remote sensor (for indoor temperature) KRCS01-5B
Note: 1When installing designer panel, body height (ceiling required dimension) is 42 mm higher than 7
The volume of fresh air for direct installation type is approximately 1% of the indoor unit airflow.
standard panel. Designer panel cannot operate 2 and 3 way flow. The chamber type is recommended when more fresh air is necessary.
2
A dedicated remote controller (BRC16A2) for the auto grille panel is included for lowering and 8
Please order using the names of both components instead of set name.
raising the suction grille. 9
This option cannot be installed to designer panel and auto grille panel.
3
When installing auto grille panel, body height (ceiling required dimension) is 55 mm higher than 10
Filter chamber is required.
standard panel. 11
Please use in case temperature/humidity inside ceiling may get over 30˚C, 80% RH.
4
Circulation airflow is not available with this option. 12
Wiring for wired remote controller should be obtained locally.
5
When installing a fresh air intake kit (chamber type), two air outlet corners are closed. 13
The indoor unit is equipped standardly with the interface adapter for SkyAir series. An option is unnecessary.
6
It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of 14
Installation box for adaptor PCB(KRP1H98A) is necessary.
the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the
operating sound and may also influence temperature sensing.

Round flow type: List of optional parts required to achieve different flow patterns
For each flow pattern – all round, 4-way, 3-way, 2-way, branch duct connection – the compatibility of each independently installed option
(shown in the column on the left) to accessory options (listed across the top of each table) is shown in the cells where the relevant row and column intersect.
A circle (o) indicates compatibility, and a cross (x) indicates incompatibility. Any options not shown below are not suitable for independent or accessory installation.

All round flow 4-way flow


Optional accessory parts Fresh air intake kit Fresh air intake kit Insulation kit High-efficiency Ultra long-life
Designer panel Auto grille panel Panel spacer1
Independently installable optional parts (Chamber type) 1 , 2 (Direct installation type) for high humidity filter unit2 filter unit2
Panel/grille related Designer panel x o o o x x x
Auto grille panel x o o o x x x
Panel spacer1 o o o o x o o
Auxillary function related Fresh air intake kit (Chamber type)1,2 o o o x x o o
Fresh air intake kit (Direct installation type) o o o x o o o
Insulation kit for high humidity x x x x o x x
Filter related High-efficiency filter unit2 x x o o o x x
Ultra long-life filter unit2 x x o o o x x
3-way flow 2-way flow 5
Optional accessory parts Fresh air intake kit Fresh air intake kit Insulation kit High-efficiency Ultra long-life
Designer panel Auto grille panel Panel spacer1,3
Independently installable optional parts (Chamber type)1,2 (Direct installation type) for high humidity filter unit2 filter unit2
Panel/grille related Auto grille panel x o o x x x
Panel spacer1,3 x x x
Auxillary function related Fresh air intake kit (Chamber type)1,2 x o x x x o
Fresh air intake kit (Direct installation type) x o x o x o
Insulation kit for high humidity x x x x o x x
Filter related Ultra long-life filter unit2 x x o o x x
Branch duct connection
Optional accessory parts Fresh air intake kit Fresh air intake kit Insulation kit High-efficiency Ultra long-life
Designer panel Auto grille panel Panel spacer1
Independently installable optional parts (Chamber type)1,2 (Direct installation type) for high humidity filter unit2 filter unit2
Branch duct chamber 1 1-way branch / unit 3-way flow o o o o o 4
x x o
(Round duct type) 2-way branch / unit 2-way flow x o x o o 4
x x o
1-way branch / unit 2-way flow x o x o o 4
x x o
1. In some cases, depending on how the unit is embedded in the ceiling, use of branch ducts and fresh air intake kits may not be possible. Before starting installation work make sure to check whether or not
joint installation is possible. In particular, ensure that the lower fixing position caused by the addition of panel spacers is acceptable.
When branch ducts are used, circulation airflow is not available.
2. When two different types of optional chambers are used together, a fresh air intake kit must be installed in the upper position.
3. It is not possible to use panel spacers in a 2-way flow installation. (△)
4. It is not possible to install a branch duct on the same side to which a fresh air intake kit (direct mount) is installed.
5. When 3-way or 2-way flow is selected, circulation airflow is not available.

54
OPTIONS

Indoor unit
COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE
No. Kit name
Name of option Remark
FFF50BV14 FFF60BV14
1 Decoration panel BYFQ60B3W1
2 Sealing material of air discharge outlet KDBH44BA60
3 Panel spacer KDBQ44BA60A
4 Fresh air intake kit Direct installation type KDDQ44XA60
5 Replacement long-life filter KAFQ441BA60
6 Remote controller Wireless type Cooling only BRC7E531W
7 Navigation remote controller Wired type 1 BRC1E62
8 Central remote controller 2 DCS302CA61
9 Unified ON/OFF controller 2 DCS301BA61
10 Schedule timer 2 DST301BA61
11 intelligent Touch Controller 2 DCS601C51
12 Adaptor for wiring 3 KRP1BA57
13 Wiring adaptor for electrical appendices (2) 3 KRP4AA53
14 Installation box for adaptor PCB KRP1BA101
15 Remote sensor (for indoor temperature) KRCS01-1B
16 Interface adaptor for SkyAir series DTA112BA51
Note:
1
Wiring for wired remote controller should be obtained locally.
2
This optional accessory requires DTA112BA51.
3
Installation box for adaptor PCB (KRP1BA101) is necessaary.

CEILING MOUNTED SLIM DUCT TYPE


Kit name
No. Name of option Remark
FDF50BV14 FDF60BV14
1 Remote controller Wireless type Cooling only BRC4C66
2 Navigation remote controller Wired type 1 BRC1E62
3 5-room centralised controller 2

4 Adaptor PCB (normal open/normal open pulse contact)3


5 The remote controller loss prevention with the chain
6 Interface adaptor for DIII-NET use
7 Central remote controller4
8 Unified ON/OFF controller4
9 Schedule timer4
10 intelligent Touch Controller 4
11 Insulation kit for high humidity

Note:
1
Wiring for wired remote controller should be obtained locally.
2
Adaptor PCB (KRP413AB1S) is also required for each indoor unit.
3
Time clock and other devices should be obtained locally.
4
This optional accessory requires KRP928BB2S.

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE


Kit name
No. Name of option Remark
FBA50BVM4 FBA60BVM4 FBA71BVM4 FBA100BVM4 FBA125BVM4 FBA140BVM4
High-efficiency filter1 65% KAFP632B80 KAFP632B160
1
90% KAFP633B80 KAFP633B160
2 Filter chamber(for rear suction)1 KDDFP63B80 KDDFP63B160
3 Long-life filter1 KAFP631B80 KAFP631B160
Service panel White KTBJ25K80W KTBJ25K160W
4 Fresh white KTBJ25K80F KTBJ25K160F
Brown KTBJ25K80T KTBJ25K160T
5 Air discharge adaptor KDAP25A71A KDAP25A140A
6 Shield plate for side plate KDBD63A160
7 Remote controller Wireless type Cooling only BRC4C66
8 Navigation Remote Controller Wired type2 BRC1E62
9 Adaptor for wiring KRP1C64
10 Wiring adaptor for electrical appendices(2) KRP4AA51
11 Mounting plate for adaptor PCB.3,4,5 KRP4A98
12 Remote sensor KRCS01-4B
13 Central remote controller6 DCS302CA61
14 Unified ON/OFF controller6 DCS301BA61
15 Schedule timer6 DST301BA61
16 intelligent Touch Controller6 DCS601C51
Note: 1If installing high efficiency filter and long-life filter to the unit, filter chamber is required. 4
Up to 2 adaptors can be fixed for each mounting plate.
2
Wiring for wired remote controller should be obtained locally. 5
Only one mounting plate can be installed for each indoor unit.
3
Mounting plate is necessary for each adaptor marked . 6
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.

55
Indoor unit
CEILING SUSPENDED TYPE
No. Kit name
Name of option Remark
FHA50BVM4 FHA60BVM4 FHA71BVM4 FHA100BVM4 FHA125BVM4 FHA140BVM4
1 Replacement long-life filter Resin net KAFP501A56 KAFP501A80 KAFP501A160
2 Fresh air intake kit KDDQ50A140
3 Drain pump kit KDUP50Q160
4 L-type piping kit (for upward direction) KHFP5N160
5 Remote controller Wireless type Cooling only BRC7M56
6 Navigation Remote Controller Wired type 1 BRC1E63
7 Central remote controller 2 DCS302CA61
8 Unified ON/OFF controller 2 DCS301BA61
9 Schedule timer 2 DST301BA61
10 intelligent Touch Controller 2 DCS601C51
11 Adaptor for wiring 3 KRP1BA54
12 Wiring adaptor for electrical appendices 3 KRP4AA52
13 Installation box for adaptor PCB KRP1D93A
14 Adaptor box mounting plate KKSAP50A56 ----------
15 Remote sensor (for indoor temperature) KRCS01-4B
16 Electrical box with earth terminal (3 blocks) KJB311AA
17 Electrical box with earth terminal (2 blocks) KJB212AA
Note:
1
Wiring for wired remote controller should be obtained locally.
2
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
3
Installation box for adaptor PCB (KRP1D93A) is necessary.

WALL MOUNTED TYPE


Kit name
No. Name of option Remark
FAA100BVM4
1 Drain-up kit K-KDU572EVE
2 Remote controller Wireless type Cooling only BRC7EB519
3 Navigation Remote Controller Wired type 1 BRC1E62
4 Wiring adaptor for electrical appendices(2) KRP4AA51
5 Installation box for adaptor PCB 2 KRP4AA93
6 Central remote controller 3 DCS302CA51
7 Unified ON/OFF controller 3 DCS301BA51
8 Schedule timer 3 DST301BA51
9 intelligent Touch Controller 3 DCS601C51
10 Remote sensor (for Indoor temperature) KRCS01-4B
11 Electrical box with earth terminal (3 blocks) KJB311AA
12 Electrical box with earth terminal (2 blocks) KEK26-1A
13 Noise filter ( For electromagnetic interface use only) KJB212AA
Note:
1
Wiring for wired remote controller should be obtained locally.
2
Installation box is necessary for each adaptor marked .
3
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.

Outdoor unit
Kit name
No. Name of option 1 Phase RZF50/60/71CVM4 RZF100CVM4 RZF125/140CVM4
3 Phase ---------- RZF71/100CYM4 RZF125/140CYM4
1 Central drain plug KKP014A4 KKP937A4 KKPJ5G280
2 Fixture for preventing overturning ---------- ---------- KKTP5B112
3 Wire fixture for preventing overturning ---------- ---------- K-KYZP15C
4 Demand adaptor ---------- KRP58M51 KRP58M51+EKMKSA1
Overvoltage PCB 1 Phase BRV2BPSF BRV2BPSS BRV2BPL
5
3 Phase ---------- BRV2BPSS+BRV2BPSS

56
DIMENSIONS (Unit: mm)

CEILING MOUNTED CASSETTE TYPE / Standard panel with Sensing

[FCF50-71CVM4]
20 20 20 20
4 - M4 6 6 4 - M4 B Connection position
950 Note) 3 Prepared hole Prepared hole of branch duct
860~910 (celing opening spec)(Note 4) 160 81 2x100=200 85
8

D
300 124 (Round shape type)
25 25 or less 710 (suspention position) 109 124
Pipe connection 95

94

94
side 420 C/L 16 - M4

E
10 Connection position Prepared hole
of branch duct

36
36

160
6 (Square-shaped type)

860-910 (celing opening spec)(Note 4)


20 - M4

780 (suspention position)


Prepared hole
950

Arrow view D Arrow view E

110
95
124
11 122

124
7

80 2x100=200 80
15 15 20 20 Connection position
350

25
Drain connection 4 - M4 5 6 4 - M4 of branch duct

122
350
side Prepared hole C C/L
Prepared hole Arrow view B (Square-shaped type)
10 25

213
94
94

Connection position
Arrow view A 9 of branch duct
ø10

36
36
(Round shape type)
(Kno 0

90
F ck h
Fresh air kit (direct type) ole)
Arrow view F Arrow view G Connection position 90
420 183

G
Arrow view C

Connection position
16 - M4 of branch duct Decoration panel
Adjustable (0~675)

Prepared hole (Square-shaped type) BYCQ125EEF Sensing panel (Fresh white)


3 (Note 2) BYCQ125EEK Sensing panel (Black)
55 840 55 Connection position 55 840 55 20 - M4
850

of branch duct Prepared hole Note:


340 81 2x100=200 85 Option decolation panel has 2 types which external
80 2x100=200 80 (Square-shaped type) Hanger
64 124 color are different.
124 50
110
124

It can be chosen one of above 2 types depend on


95

110
124
105

95
60

5 your specify.
256
246

175

165
160

150

160
125
10

1 Liquid pipe connection


42

(Required space)
20 C/L 35 or less 256 2 Gas pipe connection

hanger fixture height)


1500 or more
50

(Ceiling side-
40

122 (Note 4)
Humidifier drain pipe
122 3 Drain pipe connection
350 connection position 350
Suspention bolt Connection position 280 4 1 2 Connection position 35 or less
4 Power-source wiring and a unit wiring

130
330 of branch duct A
4 - M8~M10 of branch duct
(Round shape type) (Note 4) connection
(Round shape type)
5 Connection wiring /
Remote control wiring connection
6 Air outlet
7 Suction grille
8 Corner decoration cover
9 Sensor
10 Drain hose (accessory)
11 Drain hose connection port

Note:
1.Sticking location for Manufacture's label
Manufacture's label for Indoor unit : Suction grille inner side's electric components box's lid surface. INSTALLATION SPACE
a
Manufacture's label for Decoration panel : Decoration panel's corner decoration cover inner surface.
MORE
m OR
200m
2.In case of having option part built-in, please refer outside drawing of option part.
Fresh air kit.....................................................inspection hole Need a a
Natural evaporate type humidifier...................inspection hole Need
Air purifier unit.................................................inspection hole Need 200
mm
High performance filter unit.............................inspection hole No Need OR
MO
RE a
Branch duct chamber......................................inspection hole No Need
(both angle duct • circle duct)
- The necessary space is 500 mm or more when the air-outlet is
3.In case of using wireless remote controller. this position will be a signal receiver.
blocked with the accessory.
Refer to the drawing of wireless remote controller in detail.
Moreover when the corner areas are blocked (both right and
4.Though the installation is acceptable up to maximum of 910 mm square ceiling opening, keep the left of the blocked air outlet), the necessary space is 200 mm
clearance of 35mm or less between the indoor unit and the ceiling opening so that the panel overlap or more.
allowance can be ensured. - When the air-outlet is close to the wall surface (both sides of
the air-outlet), the recommended space is 2000 mm or more.
5.When the temperature and humidity in the ceiling exceed 30ºC and 80% RH or the fresh air is
inducted into the ceiling or the unit continues 24 hour operation, an additional insulation (thickness
10mm or more of glasswool or polyethylene form) is required.

6.Please do not place the thing been damp and troubled under an indoor unit. when the case where
humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.

7.If put vent hole, lighting, equipment near the air flow disturb equipment, ceiling surface may get dirty,
therefore shall install following to diagram as below.

INDOOR UNIT INDOOR UNIT


( 1)
VENTILATION FAN
LIGHTING

1500 OR MORE

FROM WALL 2000 OR MORE


a THE DISTANCE BETWEEN UNIT ( b)

8. For fixing position of human detection and temp sensor will be follow to diagram instruction (can not change position).
Model 50-71 100-140
a 1500-5000 1500-7000
Valid b
Circulation 5000 or more 7000 or more
air flow a 1500 or more
Invalid
b 4000 or more
( 1)Lighting is targeted for exposed type (inverse fuji-shape etc.), for embedded type (type that not expose to ceiling surface), there is no restriction.

57
CEILING MOUNTED CASSETTE TYPE / Standard panel with Sensing

[FCF100-140CVM4]
20 20 20 20
6 6 4 - M4
4 - M4 Prepared hole B
950 Note) 3 Prepared hole 160 Connection position
8 860~910 (celing opening spec)(Note 4) 81 2x100=200 85

D
300 167 of branch duct
25 25 or less 710 (suspention position) 93 67 160 (Round shape type)

136

36 136
Pipe connection 95 C/L
side 420 16 - M4
10

E
Connection position 29
Prepared hole
of branch duct

36
6

160
(Square-shaped type)

860-910 (celing opening spec)(Note 4)

93 67
20 - M4

95
780 (suspention position)

167
950 Prepared hole

29
Arrow view D Arrow view E
11

160
80 2x100=200 80
7 157
Connection position
Drain connection 15 350

25
15 20 20 of branch duct

157
350
side 5 C C/L (Square-shaped type)
4 - M4 6 4 - M4
Prepared hole Prepared hole Arrow view B

213
Arrow view A 9 10 25 Connection position

136
136
of branch duct ø10

90
(Round shape type) (Kn 0
F ock

36
36
ho le)
Fresh air kit (direct type) 90
420 Connection position 196

G
Arrow view F Arrow view G
Arrow view C

Connection position Decoration panel


of branch duct
Adjustable (0~675)

16 - M4 (Square-shaped type) BYCQ125EEF Sensing panel (Fresh white)


Prepared hole (Note 2) BYCQ125EEK
Connection position 3 Sensing panel (Black)
55 840 55
of branch duct 55 840 55 27 - M4
Prepared hole
340 Note:
80 2x100=200 80 (Square-shaped type) 64 81 2x100=200 85 Hanger Option decolation panel has 2 types which external
850

160 50 160 color are different.


167
95

167
5 It can be chosen one of above 2 types depend on

93
95
105

29
60

your specify.
160
298
288

29
175
160

150

160
10

67
165
125

42

1 Liquid pipe connection


C/L 35 or less
20 256 2 Gas pipe connection

(Required space)
50
40

1500 or more
157

(Ceiling side-
hanger fixture height)
(Note 4) 157
Suspention bolt Connection position Humidifier drain pipe 3
4 - M8~M10 of branch duct
350 connection position 350 Drain pipe connection
280 4 1 2 Connection position 35 or less 4 Power-source wiring and a unit wiring

130
(Round shape type) 330 of branch duct A
(Round shape type) (Note 4)
connection
5 Connection wiring /
Remote control wiring connection
6 Air outlet
7 Suction grille
8 Corner decoration cover
9 Sensor
10 Drain hose (accessory)
11 Drain hose connection port

Note:
1.Sticking location for Manufacture's label
Manufacture's label for Indoor unit : Suction grille inner side's electric components box's lid surface. INSTALLATION SPACE
a
Manufacture's label for Decoration panel : Decoration panel's corner decoration cover inner surface.
MORE
m OR
200m
2.In case of having option part built-in, please refer outside drawing of option part.
Fresh air kit.....................................................inspection hole Need a a
Natural evaporate type humidifier...................inspection hole Need
Air purifier unit.................................................inspection hole Need 200
mm
High performance filter unit.............................inspection hole No Need OR
MO
RE a
Branch duct chamber......................................inspection hole No Need
(both angle duct • circle duct)
- The necessary space is 500 mm or more when the air-outlet is
3.In case of using wireless remote controller. this position will be a signal receiver.
blocked with the accessory.
Refer to the drawing of wireless remote controller in detail.
Moreover when the corner areas are blocked (both right and
4.Though the installation is acceptable up to maximum of 910 mm square ceiling opening, keep the left of the blocked air outlet), the necessary space is 200 mm
clearance of 35mm or less between the indoor unit and the ceiling opening so that the panel overlap or more.
allowance can be ensured. - When the air-outlet is close to the wall surface (both sides of
the air-outlet), the recommended space is 2000 mm or more.
5.When the temperature and humidity in the ceiling exceed 30ºC and 80% RH or the fresh air is
inducted into the ceiling or the unit continues 24 hour operation, an additional insulation (thickness
10mm or more of glasswool or polyethylene form) is required.

6.Please do not place the thing been damp and troubled under an indoor unit. when the case where
humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.

7.If put vent hole, lighting, equipment near the air flow disturb equipment, ceiling surface may get dirty,
therefore shall install following to diagram as below.

INDOOR UNIT INDOOR UNIT


( 1)
VENTILATION FAN
LIGHTING

1500 OR MORE

FROM WALL 2000 OR MORE


a THE DISTANCE BETWEEN UNIT ( b)

8. For fixing position of human detection and temp sensor will be follow to diagram instruction (can not change position).
Model 50-71 100-140
a 1500-5000 1500-7000
Valid b
Circulation 5000 or more 7000 or more
air flow a 1500 or more
Invalid
b 4000 or more
( 1)Lighting is targeted for exposed type (inverse fuji-shape etc.), for embedded type (type that not expose to ceiling surface), there is no restriction.

58
DIMENSIONS (Unit: mm)

CEILING MOUNTED CASSETTE TYPE / Standard panel

[FCF50-71CVM4]
20 20 20 20
4 - M4 6 6 4 - M4 B
950 Note) 3 Prepared hole Prepared hole 160 Connection position
8 860~910 (celing opening spec)(Note 4) 124 81 2x100=200 85

D
300 of branch duct
25 25 or less 710 (suspention position) 109 124 (Round shape type)
Pipe connection 95

36 94
420 C/L

94
side 9 16 - M4

E
Connection position Prepared hole
of branch duct

36
6

160
(Square-shaped type)

860-910 (celing opening spec)(Note 4)


20 - M4

780 (suspention position)


950

Arrow view D Arrow view E Prepared hole

110
95
124
10 122

124
7

80 2x100=200 80
15 15 20 20 Connection position
Drain connection 350 of branch duct

25
4 - M4 5 6

350
122
side 4 - M4 C C/L (Square-shaped type)
Prepared hole
Prepared hole Arrow view B

213
10 25
Connection position

94
94

Arrow view A of branch duct


ø10

36
(Round shape type)
(Kn 0

90
36

F Fresh air kit (direct type) ock


ho le)
Connection position 90
Arrow view F Arrow view G 183
420

G
Arrow view C

Connection position
of branch duct
Adjustable (0~675)

(Square-shaped type) Decoration panel


16 - M4 (Note 2)
Prepared hole 3 BYCQ125EAF Standard panel (Fresh white)
55 840 55 Connection position 55 840 55 20 - M4 BYCQ125EAK Standard panel (Black)
340 of branch duct Prepared hole
81 2x100=200 85 Note:
(Square-shaped type) 64 Hanger
850

80 2x100=200 80 124 Option decolation panel has 2 types which external


124

124 50
110
95

color are different.

124
105

110
95
60

5 It can be chosen one of above 2 types depend on


your specify.
256
246

175

165
160

160
150
10

125

42

1 Liquid pipe connection


C/L 35 or less 256

(Required space)
20 2 Gas pipe connection

Hanger fixture height)


50

1500 or more
(Ceiling side-
40

122 (Note 4)
Connection position Humidifier drain pipe 122
Suspention bolt 3
4 - M8~M10 of branch duct
350 connection position 350 Drain pipe connection
280 4 1 2 Connection position
(Round shape type) 35 or less 4 Power-source wiring and a unit wiring

130
330 of branch duct A
(Round shape type) (Note 4)
connection
5 Connection wiring /
Remote control wiring connection
6 Air outlet
7 Suction grille
8 Corner decoration cover
9 Drain hose (accessory)
10 Drain hose connection port

CEILING MOUNTED CASSETTE TYPE / Standard panel

[FCF100-140CVM4]
20 20 20 20
6 6 4 - M4
4 - M4 Prepared hole B
Note) 3 Prepared hole
950 160 Connection position
8 300 860~910 (celing opening spec)(Note 4) 167 81 2X100=200 85
D

of branch duct
25 25 or less 710 (suspention position) 93 67 160
136

136

Pipe connection (Round shape type)


420 95 C/L
side 29 16 - M4
E

9 Connection position Prepared hole


36

of branch duct
36

160

6 (Square-shaped type)
860-910 (celing opening spec)(Note 4)

93 67

20 - M4
95
167
950

Arrow view E Prepared hole


780 (suspention position)

Arrow view D
29

10
80 2X100=200 80

7 15 15
160

20 20 157
5 Connection position
Drain connection 4 - M4 6 4 - M4 350 of branch duct
25

350
157

side Prepared hole Prepared hole (Square-shaped type)


C C/L
Arrow view B
10 25
136
136

213

Connection position
Arrow view A of branch duct
36
36

(Round shape type) O10


90

F (Kno 0
Fresh air kit (direct type) ck h
connection position ole)
Arrow view F Arrow view G 90
420 196
G

Connection position
Adjustable (0~675)

Arrow view C
16 - M4 of branch duct
Prepared hole (Square-shaped type)(Note 2)
Connection position 3
55 840 55 55 840 55 27 - M4
of branch duct
340 Prepared hole
(Square-shaped type) 64 81 2X100=200 85
80 2X100=200 80 Hanger
850

167

160
95

160 50 Decoration panel


167
95
93

5
105

29
60

BYCQ125EAF Standard panel (Fresh white)


160

BYCQ125EAK Standard panel (Black)


298
288

175
29
160

160

Note:
150
10

165
125

67
42

Option decolation panel has 2 types which external


color are different.
(Required space)

20 C/L 35 or less 256 It can be chosen one of above 2 types depend on


50
40

Hanger fixture

157 (Note 4)
1500 or more

157 your specify.


Ceiling side-

350 Humidifier drain pipe 350


Suspention bolt Connection position 280 connection position 35 or less
height)

4 - M8~M10 of branch duct 330 4 1 2 (Note 4)


Connection position 1 Liquid pipe connection
130

(Round shape type) A


of branch duct
(Round shape type) 2 Gas pipe connection
3 Drain pipe connection
4 Power-source wiring and a unit wiring
connection
5 Connection wiring /
Remote control wiring connection
6 Air outlet
7 Suction grille
8 Corner decoration cover
9 Drain hose(accessory)
10 Drain hose connection port

59
CEILING MOUNTED CASSETTE TYPE / Designer panel

[FCF50-71CVM4]

20 20 20 20
950 Note) 3 4 - M4 6 6 4 - M4 B
8 Prepared hole Prepared hole 202 81 2X100=200 85 Connection position
860~910 (celing opening spec)(Note 4)

D
300 124 124 of branch duct
Pipe connection 25 25 or less 710 (suspention position) 109
side C/L (Round shape type)
95

94

94
420 16 - M4
9

E
6 Connection position Prepared hole
of branch duct

36

202
36
(Square-shaped type)

860-910 (celing opening spec)(Note 4)


950
20 - M4
7 Prepared hole

780 (suspention position)


Arrow view D Arrow view E

110
95
124
15 15 20 20 10

124
80 2X100=200 80
122 Connection position
Drain connection 4 - M4 5 6 4 - M4 350 of branch duct

25
side Prepared hole
Prepared hole

122
350
C C/L (Square-shaped type)
10 Arrow view B
25

94
94

213
Arrow view A Connection position
of branch duct

36
36 (Round shape type) O10

90
F Fresh air kit (direct type) (Kno 0
ck h
connection position ole)
Arrow view F Arrow view G 90
420 225

G
Connection position of branch duct Arrow view C
Adjustable (0~675)

16 - M4 (Square-shaped type)(Note 2)
Prepared hole Connection position 3
55 840 55 of branch duct 55 840 55 20 - M4
(Square-shaped type) Prepared hole
340 81 2X100=200 85
80 2X100=200 80 64 Hanger
905

124
124
110

124 50
95

124
105

110
95
60
5
298
246

217

207
52

192
202

167

202
42

Decoration panel
C/L 35 or less 256

(Required space)
20 BYCQ125EAPF
97

Designer panel
45

122 (Note 4) 122

1500 or more
Humidifier drain pipe 35 or less

Hanger fixture
Suspention bolt Connection position 350 350
4 1 2

Ceiling side-
4 - M8~M10 of branch duct connection position (Note 4)
280
(Round shape type) Connection position A

172
330 1 Liquid pipe connection

height)
of branch duct
(Round shape type) 2 Gas pipe connection
3 Drain pipe connection
4 Power-source wiring and a unit wiring
connection
5 Connection wiring /
Remote control wiring connection
6 Air outlet
7 Suction grille
8 Corner decoration cover
9 Drain hose(accessory)
10 Drain hose connection port

CEILING MOUNTED CASSETTE TYPE / Designer panel

[FCF100-140CVM4]

20 20 20 20
950 Note) 3 4 - M4 6 6 4 - M4
Prepared hole B
8 Prepared hole 202 Connection position
860~910 (celing opening spec)(Note 4) 81 2X100=200 85
167
D

300 of branch duct


Pipe connection or less 710 (suspention position) 93 67 160
25 25
136

136

side 95 C/L (Round shape type)


420 16 - M4
29
E

6 9 Connection position Prepared hole


36

of branch duct
202
36

(Square-shaped type)
860-910 (celing opening spec)(Note 4)

93 67
950

20 - M4
95
167

7 Prepared hole
780 (suspention position)

Arrow view D Arrow view E


29

10
160

15
80 2X100=200 80

15 20 20 157
Drain connection 5 Connection position
4 - M4 4 - M4 350 of branch duct
25

side 6
350

Prepared hole
157

Prepared hole C C/L (Square-shaped type)


Arrow view B
10 25
136
136

213

Arrow view A Connection position


of branch duct
36
36

(Round shape type)


90

O10
F Fresh air kit (direct type) (Kno 0
connection position ck h
ole)
Arrow view F Arrow view G 90
420 238
G

Connection position
Adjustable (0~675)

16 - M4 Arrow view C
of branch duct
Prepared hole
Connection position 3 (Square-shaped type)(Note 2)
55 840 55 55 840 55 27 - M4
of branch duct
340 (Square-shaped type) Prepared hole
80 2X100=200 80 64 81 2X100=200 85 Hanger
167

160
905

95

160 50
167
95
93

5
105

29
60
160
340
288

29

Decoration panel
52

217
202

202
192

67
42
167
207

BYCQ125EAPF Designer panel

20 C/L 157 35 or less 256


(Required space)
97
45

(Note 4) 157
1 Liquid pipe connection
Hanger fixture

350 Humidifier drain pipe


1500 or more

Suspention bolt Connection position 350 35 or less


Ceiling side-

4 - M8~M10 of branch duct 280 4 1 2 connection position (Note 4)


(Round shape type) 330 Connection position 2 Gas pipe connection
height)

A
of branch duct 3 Drain pipe connection
172

(Round shape type)


4 Power-source wiring and a unit wiring
connection
5 Connection wiring /
Remote control wiring connection
6 Air outlet
7 Suction grille
8 Corner decoration cover
9 Drain hose(accessory)
10 Drain hose connection port

60
DIMENSIONS (Unit: mm)

CEILING MOUNTED CASSETTE TYPE / Auto grille panel

[FCF50-71CVM4]

20 20 20 20
8 6 6 4 - M4
950 Note) 3 4 - M4 B
Prepared hole Prepared hole 215 81 2X100=200 85 Connection position
300 860~910 (celing opening spec)(Note 4) 124

D
124 of branch duct
Pipe connection 25 25 or less 710 (suspention position) 109
side C/L (Round shape type)

94

94
420 95 16 - M4
10

E
Connection position Prepared hole
6 of branch duct

36

215
36
(Square-shaped type)

860~910 (celing opening spec)(Note 4)


20 - M4
950

7
Arrow view E Prepared hole

780 (suspention position)


Arrow view D

110
95
124
15 15 11

124
80 2X100=200 80
20 20 122
Drain connection 4 - M4 5 6 Connection position
4 - M4 350

25
side Prepared hole of branch duct
Prepared hole

122
350
C C/L (Square-shaped type)
Arrow view B
10 25

94
94

213
9 Connection position
Arrow view A 36
36

of branch duct
(Round shape type) O10

90
F (Kno 0
Fresh air kit (direct type) ck h
connection position ole)
Arrow view F Arrow view G 90
420 238

G
Connection position Arrow view C
Adjustable (0~675)

16 - M4 of branch duct
Prepared hole 3 (Square-shaped type)(Note 2)
Connection position
55 55 of branch duct 55 840 55 20 - M4 OPTIONAL WIRELESS REMOTE CONTROLLER
840
340 (Square-shaped type) 81 2X100=200 85 Prepared hole 43 BRC16A2
80 2X100=200 80 64 Hanger
905

124
124
110

124 50
105
95

124
110
60

95
STOP ��

5
AUTO GRILLE
躩鎮詩跲���賻

UP 迣

DOWN覺
311
246

133
BRC16A2
65

230

220
215

215
205

EMERGENCY
180

42

LIFTING/LOWERING

LIFTING/LOWERING STAGE

C/L 35 or less 256

(Required space)
20
105

(Note 4)
40

122

Hanger fixture
AUTO GRILLE
122

Ceiling side-

1500 or more
Suspention bolt Connection position 350 Humidifier drain pipe 350 35 or less
4 - M8~M10 of branch duct 4 1 2 connection position (Note 4) 18.5
280

height)
(Round shape type) Connection position

185
330 A AUTO GRILLE RECEIVER WIRELESS REMOTE CONTROLLER
of branch duct
(Round shape type)
Decoration panel
BYCQ125EASF Auto grille panel

1 Liquid pipe connection 6 Air outlet


2 Gas pipe connection 7 Suction grille
3 Drain pipe connection 8 Corner decoration cover
4 Power-source wiring and a unit wiring 9 Auto grille receiver
connection 10 Drain hose(accessory)
5 Connection wiring / 11 Drain hose connection port
Remote control wiring connection

CEILING MOUNTED CASSETTE TYPE / Auto grille panel

[FCF100-140CVM4]

20 20 20 20
8 6 6 4 - M4
950 Note) 3 4 - M4 Prepared hole B
Prepared hole 215 Connection position
860~910 (celing opening spec)(Note 4) 81 2X100=200 85
167
D

300 of branch duct


Pipe connection or less 710 (suspention position) 93 67 160
25 25
136

136

side 95 C/L (Round shape type)


420 16 - M4
10 29
E

Connection position
of branch duct Prepared hole
6
36

215
36

(Square-shaped type)
860~910 (celing opening spec)(Note 4)

93 67

7 20 - M4
950

95
167

Arrow view E Prepared hole


780 (suspention position)

Arrow view D
29

11
160

15
80 2X100=200 80

15 20 20 157
Drain connection 5 Connection position
4 - M4 4 - M4 350
25

side 6 of branch duct


157
350

Prepared hole Prepared hole


C C/L
Arrow view B (Square-shaped type)
10 25
136
136

213

9
Arrow view A Connection position
of branch duct
36
36

90

(Round shape type) O10


F (Kno 0
Fresh air kit (direct type) ck h
connection position 90 ole)
Arrow view F Arrow view G
420 251
G

Arrow view C
Adjustable (0~675)

16 - M4 Connection position of branch duct


Prepared hole (Square-shaped type)(Note 2)
Connection position 3 27 - M4
55 840 55 55 840 55
of branch duct Prepared hole
340 OPTIONAL WIRELESS REMOTE CONTROLLER
80 2X100=200 80 (Square-shaped type) 64 81 2X100=200 85 Hanger
160 43
167
905

160 50 BRC16A2
95

167
95
93
105

5
29
60

STOP ��
160

AUTO GRILLE
躩鎮詩跲���賻
353

UP 迣
288

29

DOWN覺
65

230
215

215
205

67
42
180
220

133

BRC16A2

EMERGENCY
LIFTING/LOWERING

20 C/L 35 or less 256


(Required space)

LIFTING/LOWERING STAGE
105

157
40

(Note 4)
Hanger fixture

157
Ceiling side-

350
1500 or more

Suspention bolt Connection position Humidifier drain pipe 350 35 or less AUTO GRILLE

4 - M8~M10 of branch duct 280 4 1 2 connection position (Note 4)


height)

(Round shape type) 330 Connection position 18.5


A
185

of branch duct AUTO GRILLE RECEIVER WIRELESS REMOTE CONTROLLER


(Round shape type)

Decoration panel
BYCQ125EASF Auto grille panel

1 Liquid pipe connection 1 Liquid pipe connection


2 Gas pipe connection 2 Gas pipe connection
3 Drain pipe connection 3 Drain pipe connection
4 Power-source wiring and a unit wiring 4 Power-source wiring and a unit wiring
connection connection
5 Connection wiring / 5 Connection wiring /
Remote control wiring connection Remote control wiring connection

61
COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE

[FFF50/60BV14]

585~660 (ceiling opening space) 89


700 210
300 or less 533 (suspension position)
320
Note)2.
Ceiling

585~660 (ceiling opening space)


Drain connection side

533 (suspension position)

89
ø1
00
B

150
6 8
700

4-M4 hole
Outdoor air intake
(Direct connection)
7

B Arrow view
Pipe connection side

A Arrow view 320

Required space

ore ※
m or m
1500m
15
Adjustable(0~545)

or 00mm
mo
150 re
62.5 575 62.5 or m 0mm ※
ore

62.5 575 62.5 ore ※
m or m

295 or more
750

3 1 5 1500m
※ When the discharge grille is closeout,
the required space is 200mm or more.

(180)
285
260

205

183
145

(Required space)
25

5-45 5-45
4

1500 or more
Note)4.

For height installation


Decoration panel

From the floor side


2
30

BYFQ60B8W1
55

White ral 9010

295 or more
196 172
Suspension bolt 211 A
4-M8~M10

Notes:
1
Sticking location for manufacture's label 1 Liquid pipe connection
Manufacture's label for indoor unit : on the bell mouth inside suction grille
2 Gas pipe connection
Manufacture's label for decoration panel : on the inner frame inside suction grille
2
In case of using wireless remote controller, this position will be a signal receiver. 3 Drain pipe connection
Refer to the drawing of wireless remote controller in detail. 4 Power supply connection
3
When the temperature and humidity in the ceiling exceed 30℃ and rh 80% or the fresh air 5 Remote control wiring / control wiring connection
Is inducted into the ceiling or the unit continues 24 hour operation,an additional
Insulation (thickness 10mm or more of glasswool or polyethylene form) is required. 6 Air discharge grille
4
Though the installation is acceptable up to maximum of 660mm square ceiling opening, 7 Suction grille
Keep the clearance of 5-45mm between the main unit and the ceiling opening so that 8 Drain hose (accessory)
The panel overlap allowance can be ensured.

CEILING MOUNTED SLIM DUCT TYPE

[FDF50/60BV14]
20 or more

1100 300 or more 400 or more


(Service space) (In case of bottom suction) 620
20 or more

240 or more
(Suspension bolt pitch)

1100
620

500

Ceiling
60

300

<Service space>
8 26-o4.7hole
(All around)
10xP100=1000
1140 Allow view
(Suspension bolt pitch) Inspection door
(Ceiling opening)

Suspension bolt
4-m8~m10 1080
1060 130 63 24-m5 holes 10
21
57.5
12.5

6xP150=900 2 1 (All around)


20
50

10
90
100 47

170

180
170
153
200

160
100
80

7
23

30 330 9xP100=900
3 5 150 9
18-m4 holes 4 100 980
(All around)
90 1000
80 1020
<In case of back-suction>

24-m5 holes
(All around)
1 Liquid pipe connection
2 Gas pipe connection
6 3 Socket for drain
Notes: 4 Drain hose (standard accessory)
200

160
180

100

10
1.In case of back-suction, mount chamber cover to bottom side of the unit. 5 Control box
9xP100=900 130
9 In case of bottom-suction, mount chamber cover to back side of the unit. 6 Transmission wiring connector
50
20
10

980 100 2.Location of unit`s name plate: control box cover. 7 Power supply connection
1000 90 3.Mount the air filter at the suction side.
1020 80 (Select its colorimethod(gravity method) 50% or more.)
8 Suspension bracket
<In case of bottom-suction> It can not be equipped with air filter(accessory) 9 Air filter (standard accessory)
When connecting duct to suction side. 10 Protection net

62
DIMENSIONS (Unit: mm)

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE

[FBA50-71BVM4]
Inspection hatch 2
30-φ4.7hole 134 630 10 450 or more CASE1) Control box
(All around) (Hanging bolt position) Inspection hatch 1
( Drain

300 or more
pan removal
and part exchange. )
(450x450)
Inspection hatch 3

200 or less
8 ※When can work enters (SAME AS THE INDOOR
UNIT SIZE +300 OR MORE)
the space under the unit,
inspection hatch 2 is Control box
unnecessary.
Control box
9 Inspection hatch Fig.A
Ceiling

1300 or more
11x65=715
1038(Hanging bolt position)

CASE 2),3)

1000 or more
Control box
835

Inspection hatch1
(450x450)

or less
20 or more
Air Air inlet

200
outlet Control box
13x65=845 800 or more 800 or more
1000
36-φ4.7hole Inspection hatch 2

500
Inspection hatch View B-1 View B-2

500

(All around) (SAME AS THE INDOOR Unit base
Ceiling UNIT SIZE OR MORE)

Air outlet Air inlet

Suspention
200 or less

16-8x12 oblonghole (4pieces) bolt Fig. A-1 Inspection hatch 2※


450 (450X450)
53
(Service space)

65
69

(All around)
450 or more

13
176
100
194

Notes:
Drain pan
1
Locations of Manufacturer's Label:Surface of a control box
5x156=780 26 2
Make sure to mount the air filter inside the air passage on
138

maintenance space
792
Control Box
the suction side. (Select Duct Collection Efficiency
Inspection hatch 1 815
450 or more 800 or more maintenance space <Gravimetric Method>50% or more.)
View 3
If the temperature and humidity in the ceiling is likely to
(Service space)
(From the Air outlet) exceed 30℃ and RH80%, strengthen heat insulation by
12 applying the additional insulation materials such as glass
3x50=150
(643 or less)

1 2 6 5 3
300 or less 499 wool or polyethylene that has thickness of 10mm or more.
2x50=100
207 Adjustable

4
Do not put things that should not get wet under the indoor unit.
850 or less

Dews may drop when humidity reaches over 80%, a drain


gets stuck or air filters are not clean.
Space for Service Works
245

222
Air Air inlet
183

208
136

226
123

outlet (Note.2)
Provide service spaces for service work such as check and
6x150=900 maintenance of the control box and drain pump by one of the
60

91
38

4 7 952 following ways.


300 or more

(A case without

179 50
2500 or more

11
(Note.5)

977
the ceiling)

300 1)Inspection hatch 1and 2(450x450) (Fig.A-1) and a space of


Drain pan maintenance 800
18-8x12 oblong hole (From the Air inlet) 300mm or more under the unit. (Fig.A)
check hole (All around) Note:Inspection hatch 2 is not needed when there is a space for
Ceiling Floor surface service work under the unit.
2)Inspection hatch 1(450x450) on the control box side, and
Inspection hatch 2 under the unit. (View B-1)
1 Liquid pipe connection 6 Remote control wiring connection 11 Socket(For maintenance) 3)Inspection hatch 3 under the unit and control box. (View B-2)
2 Gas pipe connection 7 Power supply wiring connection 12 Drain hose(Accessory)
Provide enough space for maintenance and mount the drain
3 Drain pipe connection 8 Air discharge flange 13 Drain hose connection(Accessory) pan and control box.
4 Earth terminal(terminal in Control box) 9 Air suction flange Check the drawing of optional accessories when mounting
5 Control box(Inside) 10 Hanger optional accessories such as filter chamber and humidifier.

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE

[FBA100-140BVM4]
44-φ4.7hole 134 630 10
(All around) (Hanging bolt position) 50-φ4.7hole
(All around) CASE1) Control box
8
9
300 or more

Inspection hatch 1
(450x450) Inspection hatch 3
200 or less

Inspection hatch 2
450 or more (SAME AS THE INDOOR
UNIT SIZE +300 OR MORE)
( Drain pan removal
and part exchange. ) Control box
Inspection hatch
1438(Hanging bolt position)

Control box Fig.A Ceiling


1700 or more
18x65=1170

※When can work enters


the space under the unit, CASE 2),3) Control box
20x65=1300

1400 or more
1235

inspection hatch 2 is Inspection hatch1


200 or less

unnecessary.
1400

(450x450)
20 or more

Control box
Air inlet 800 or more 800 or more
Air B Inspection hatch 2
Inspection hatch View B-2
500

outlet View B-1


Ceiling (SAME AS THE INDOOR
UNIT SIZE OR MORE)
Air inlet
500

Air outlet
Unit base

650 20-8x12 oblonghole bolt Inspection hatch 2※


Suspention
(All around) (4pieces) (450X450)
200 or less

Fig. A-1
(Service space)
450 or more

53
65
69

176
100
194

Notes:
13 1
Locations of Manufacturer's Label:Surface of a control box
Control Box 26
maintenance space 7x156=1092
2
Make sure to mount the air filter inside the air passage on
138

Drain pan the suction side. (Select Duct Collection Efficiency


1192
maintenance space <Gravimetric Method>50% or more.)
1215
Inspection hatch 1
3
If the temperature and humidity in the ceiling is likely to
800 or more View
450 or more exceed 30℃ and RH80%, strengthen heat insulation by
(Service space) (From the Air outlet) applying the additional insulation materials such as glass
12
3x50=150

300 or less wool or polyethylene that has thickness of 10mm or more.


(643 or less)

699
2x50=100

2
207 Adjustable

1 6 5 Do not put things that should not get wet under the indoor unit.
850 or less

4
3
Dews may drop when humidity reaches over 80%, a drain
gets stuck or air filters are not clean.
5
Space for Service Works
226
208
245

Air inlet
60

222
183

Air (Note.2)
136

123

outlet Provide service spaces for service work such as check and
91 26-8x12 oblong hole maintenance of the control box and drain pump by one of the
38

300 or more

4 7
(A case without
2500 or more

100 100 6x150=900 100 100 following ways.


50
(Note.5)

11 179 (All around)


the ceiling)

300 1352
1377
1)Inspection hatch 1and 2(450x450) (Fig.A-1) and a space of
Drain pan maintenance 800
check hole 300mm or more under the unit. (Fig.A)
(From the Air inlet)
Note:Inspection hatch 2 is not needed when there is a space for
Ceiling Floor surface service work under the unit.
2)Inspection hatch 1(450x450) on the control box side, and
1 Liquid pipe connection 6 Remote control wiring connection 11 Socket(For maintenance) Inspection hatch 2 under the unit. (View B-1)
2 Gas pipe connection 7 Power supply wiring connection 12 Drain hose(Accessory) 3)Inspection hatch 3 under the unit and control box. (View B-2)
3 Drain pipe connection 8 Air discharge flange 13 Drain hose connection(Accessory) Provide enough space for maintenance and mount the drain
4 9 pan and control box.
Earth terminal(terminal in Control box) Air suction flange
Check the drawing of optional accessories when mounting
5 Control box(Inside) 10 Hanger optional accessories such as filter chamber and humidifier.

63
CEILING SUSPENDED TYPE

210
[FHA50/60BVM4] 156
Connection position of fresh air intake kit
105 φ100(Knock out hole)
18 17 20 16 120
102 9
131 57 90

35

157 63
92
175
87
163
30

100

90
189

115
210

195

40
63

bolt pitch)
(Hanging
116 51 60 134 59
12

260
10 Position slit hole for taking out in pipe back
(View from the front)

(Required space)
8
(Required space)

220
920 103
690 (Hanging bolt pitch) 19 15

5
Hanging bolt
5

4 11

175
4-M8~M10 1 5
197

91
131
197
235

Position : Hole of wall for taking out in pipe back


From the floor side 2500 or more

(Required space)

(View from the front)


For height installation

300 or more

13 57
57 6 14
30 or more 960 30 or more φ 45
(Service space) (Service space)
Obstacle
The Front
Floor side Brand name plate 1 Air discharge grille
(Note.2) 2 Air suction grille
3 Air filter
4 Gas pipe connection
Drain piping connection VP20
6 5 Liquid pipe connection
(For left pipe)
6 Drain pipe connection
7 Earth terminal (inside the control box) (M4)
8 Hanger
9 Rear pipe penetration cover
268

268
221
214

10 Top panel penetration cover


11 Right side pipe connection
76 83 12 Left back drain pipe connection
3 2 7 5 105 4
13 Left side drain pipe connection
156
Notes: 14 Right side drain pipe connection
1
Location of unit's Name Plate: Bottom of fan housing inside the suction grille. 15 Hole of wall for taking out in pipe back
2
In case of using wireless remote controller, this position will be a signal receiver. 16 Upward drain pipe connection
Refer to the drawing of wireless remote controller in detail. 17 Upward gas pipe connection
3
Please do not place the thing been damp and troubled under an indoor unit. 18 Upward liquid pipe connection
When the case where humidity is 80% or more, and the drain outlet are choked up 19 Power supply wiring and a unit wiring back connection
and the air filter are dirty, dew may fall. 20 Power supply wiring and a unit wiring upper connection

CEILING SUSPENDED TYPE

[FHA71BVM4]
210 Connection position of fresh air intake kit
156
105 φ100(Knock out hole)
18 17 20 16 120
102 9
131 57 90
35

157 63
92
175
87
30

163
189
100
210

115
90
195

40

63
bolt pitch)
(Hanging

116 51 60 134 59
260

12
10
Position slit hole for taking out in pipe back
(Required space)

(View from the front)


8
(Required space)

220
103
1230 19 15
690 (Hanging bolt pitch)
5

Hanging bolt 4 5 11
175
5

4-M8~M10 1
91
131
197

197

Position : Hole of wall for taking out in pipe back


235

(View from the front)


(Required space)
From the floor side 2500 or more

57
6
For height installation

300 or more

13 14
57 φ45
30 or more 1270 30 or more
(Service space) (Service space)
The Front 1 Air discharge grille
Obstacle Brand name plate
2 Air suction grille
Floor side (Note.2)
3 Air filter
4 Gas pipe connection
Drain piping connection VP20 5 Liquid pipe connection
6 6 Drain pipe connection
(For left pipe)
7 Earth terminal (inside the control box) (M4)
8 Hanger
9 Rear pipe penetration cover
268
268

221
214

10 Top panel penetration cover


11 Right side pipe connection
76 83 12 Left back drain pipe connection
3 2 7 5 105 4 13 Left side drain pipe connection
156 14 Right side drain pipe connection
Notes: 15 Hole of wall for taking out in pipe back
1
Location of unit's Name Plate: Bottom of fan housing inside the suction grille. 16 Upward drain pipe connection
2
In case of using wireless remote controller, this position will be a signal receiver. 17 Upward gas pipe connection
Refer to the drawing of wireless remote controller in detail. 18 Upward liquid pipe connection
3 Please do not place the thing been damp and troubled under an indoor unit. 19 Power supply wiring and a unit wiring back connection
When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall. 20 Power supply wiring and a unit wiring upper connection

64
DIMENSIONS (Unit: mm)

CEILING SUSPENDED TYPE

[FHA100-140BVM4]
210
156 Connection position of fresh air intake kit
105 120
18 17 20 16 102 φ100(Knock out hole)
9
131 57 90

35

157 63
92
87
30

163
189
100

90
210

175

115
195

40
63
bolt pitch)
(Hanging
116 51 60 134 59
260

10 12
Position slit hole for taking out in pipe back

(Required space)
(View from the front)
8
220
(Required space)

103
1550 19 15
690 (Hanging bolt pitch)

5
Hanging bolt
4-M8~M10 1 4 5 11

175
5

91
131
197

197
235

Position : Hole of wall for taking out in pipe back


(View from the front)
From the floor side 2500 or more

(Required space)

57
For height installation

14
300 or more

13 6
57 30 or more 1590 30 or more
(Service (Service φ45
space) space)
The Front
1 Air discharge grille
Obstacle Brand name plate
2 Air suction grille
Floor side (Note.2)
3 Air filter
4 Gas pipe connection
Drain piping connection VP20 5 Liquid pipe connection
(For left pipe) 6 6 Drain pipe connection
7 Earth terminal (inside the control box) (M4)
8 Hanger
9 Rear pipe penetration cover
268

268
221
214

10 Top panel penetration cover


11 Right side pipe connection
76 83 12 Left back drain pipe connection
3 2 7 5 105 4
13 Left side drain pipe connection
156 14 Right side drain pipe connection
Notes: 15 Hole of wall for taking out in pipe back
1
Location of unit's Name Plate: Bottom of fan housing inside the suction grille. 16 Upward drain pipe connection
2
In case of using wireless remote controller, this position will be a signal receiver. 17 Upward gas pipe connection
Refer to the drawing of wireless remote controller in detail. 18 Upward liquid pipe connection
3 Please do not place the thing been damp and troubled under an indoor unit. 19 Power supply wiring and a unit wiring back connection
When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall. 20 Power supply wiring and a unit wiring upper connection

WALL MOUNTED TYPE

[FAA100BVM4]

Piping direction
(Required space)

Approx.440
50 or more

242
240

7
(Required space)
340

Dimensions for
30 or more

full open
front panel
8

3
9 1 Piping direction Name plate Note)2 Piping direction 2500 or more 120 or less
2 50 or more 1200 50 or more
For installation
(Requred space) (Requred space) in high spaces

79.5 1085 35.5


14.5

φ80 hole
Outside line
Piping and
φ80 hole Wiring intake
114
45

45

1 Front panel
65 6 Approx.400 89 2 Front grill
5 3 Air outlet
Approx.460
4 Gas pipe
Mounting location 4 Approx.465
Notes: 5 Liquid pipe
1
Location of unit's of Name Plate:Right side surface of casing 6 Drain hose
2
In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote contorller in detail. 7 Earth terminal
3
Please do not place the thing been damp and troubled under an indoor unit. when the case where humidity is 80% or more, 8 Right side pipe connection hole
and the drain outlet are choked up and the air filter are dirty, dew may fall. 9 Left side pipe connection hole

65
OUTDOOR UNIT // RZF50/60/71CVM4

Drain outlet
I.D.O 18 hose for connection
845 78
300
131 573.5
342
326
300

4-hole for anchor bolts


20

Earth terminal
7

(M8 or M10) in switch box


Name plate Wiring inlet
595

60
105
144 20
Service port
Liquid stop vale
112
163
269

272

Service port Gas stop vale

Drain outlet
21

94
200 Drain outlet
299
419
449

479
509
559

OUTDOOR UNIT // RZF100CVM4, RZF71/100CYM4

15 930 46 350

Handle
695

420
Power supply wiring intake
Control wiring intake

145 610 175


(Installation leg pitch)
(Installation leg pitch)
376

50

Grounding terminal
11

24

497

Drain outlet
Liquid stop valve

Service port
Gas stop valve

66
DIMENSIONS (Unit: mm)

OUTDOOR UNIT // RZF125/140CVM4 / CYM4

Hole for anchor


bolt 4-M12

30
(345~355)
350

320
55
37
38

30
91
160 620 160
30 940 3

4
7
2
6
1
990

7 5
5 6
5

55
60

55
340
339

223
95
95

95

84
53

53
89 19

53
89

19 80 52
7 6 142
145 13 67
8 90 16
16

1 Gas pipe connection


161
260

68

2 Liquid pipe connection


285
279

3 Service port
5 4 Earth terminal
36
61 5 Refrigerant piping intake
262 6 Power supply wiring intake
416 7 Transmission wiring intake
595
8 Drain pipe connection

67
REMOTE CONTROLLER

Wireless type

• Remote controller dimensions • Remote controller dimensions


23.5 CEILING MOUNTED CASSETTE TYPE <Round Flow>
Transmitting part • Receiver installation procedure
Receiver

Refrigerant
Piping side

Decoration

157
189

panel

62 17.5 Drain piping


58.5 side
• Remote controller holder

installation procedure Sensor


Remote controller holder • Receiver detail
Installation procedure Wireless remote control <installation to wall surface>
〈Installation to wall surface〉
Liquid crystal
remote controller
(wireless)

Remote controller
holder
Remote control

COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE CEILING MOUNTED BUILT-IN TYPE CEILING SUSPENDED TYPE
• Receiver installation procedure DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE • Receiver installation procedure
Receiver
Drain piping Refrigerant piping • Receiver detail
side side 2-5x9 Slot
(Ceiling opening)

Receiver
83.5
120

106
72

0.5 49 • Receiver detail


70 18 35
(Ceiling opening)

Switch box
(field Supplied parts)

Service space for ceiling installation


• Receiver detail Decoration panel WALL MOUNTED TYPE
Note :
(Srevice space)

(BYFQ60BW1) • Receiver installation procedure


More than 90

Do not install more than 3


(BYFQ60B7W1) receivers in the vicinity of Receiver
(BYFQ60B8W1) one another.
With 4 or more units, there
is always the possibility of
malfunction

• Receiver
detail

Wired type • Remote controller dimensions

BRC1E62/63
Remote controller dimensions Upper case Lower case
Installation method
A Exposed cord Conduit
Staple B Embedded cord C Embedded cord (use switch box)
Top left 19 19
Top center
42

outlet outlet
Operation
lamp
120

84

(Green)
40

84

84
40

Code outlet hole


120 19 28
48.5 Note)2 28 46
23 48.5 5×15 Oblong hole Through hole
5×7 Oblong hole 0~5
46 Left outlet Switch box for one switch Switch box for two Between remote
(ø8~ø10)
control box )
( controller
19 Lower case portion Ex.)KJB111A switch and
(optional accessory) Ex.)KJB211A
Lower case portion (optionalAccessory) Switch box
[field supplied part]
Specifications of cord
Note)
1. Remote controller cord and staple are not attached. They are field Type Vinyl cord with sheath or cable (insulated thickness: 1mm or more)
supplied parts.
Size 0.75~1.25 mm2
2.If the hole size is too large or the location is not proper, the hole
may come out from the remote controller. Total length 500 m

68
Installation service space for outdoor unit (Unit: mm)

For RZF50-140CVM4, RZF71-140CYM4 series


1.RZF50/60/71/100CVM4, 71/100CYM4 2.RZF125/140CVM4 / CYM4 series

1 When there is an obstruction on the inlet side 2 When there is an obstruction on the outlet side

1) When the overhead space is open 1) When the overhead space is open
1 2
1. For single unit installation 1. For single
When there is an 1 2
unit installation
obstruction only
on the inlet side 0 rm
ore
50 ore 0o
or
m 50
re
mo 0 2. For multiple units installation (more than two units)
or 10 ore
50 m 10
or 0
mo or
When there are obstructions on 1 2 re 10
0
mo or
both sides re

1 2
25
0o
rm
ore
10 10 re
0o
rm 0o mo mo
re
ore rm or or
ore 00
25 ore 10 10 00
0
0o rm 0o 0
10 ore
1
rm 0o rm
ore 10 ore or
m
2) When there is an obstruction in the overhead space
1. For single unit installation
2. For multiple units installation An obstruction
ss ss
(more than two units) 10 o r le
in the overhead
0o
r le
0
mo or 500 space 50

1000 or more
When there are re 10

1000 or more
0
mo or 1 2
re
obstructions on
both sides 10
00
or
mo
re

re
20 mo
0o
rm 0 or
ore 30 re ore
mo rm
or
50
0 0o
50

2. For multiple units installation (more than two units)


ss
2) When there is an obstruction in the overhead space 0o
r le
ss
0o
r le
50 50
1 2

1000 or more
1. For single unit installation
1000 or more

10
0
mo or
re
When there is an obstruction on the inlet side
ss
r le
1000 or more

1 s 2 0o
r les 50 10
0o
or more

0
50 mo or
1000

re
25
An obstruction 0o
rm
in the overhead ore
An obstruction re
space re
mo in the overhead mo
r or
0 0o space 00
10 10
ore
rm 0
0o 10 ore
10 m
or
3 When there are obstructions on both
When there are obstructions on the inlet side and
both lateral sides
the inlet and outlet sides
An obstruction
in the overhead ss
(When the obstruction on the outlet side is higher than the
1000 or more

s
les r le
or 0o unit itself)
1000 or more

0 space 50
50
1 2
1) When the overhead space is open
(There is no limit to the height of the obstruction on the
outlet side.)
or 150 or 150
mo re mo
re mo re 0 1. For single unit 1 2
or 250 0o
r or 150 15 ore
mo
re
15 mo
re or
m
installation
H
L

2. For series installation (more than two units)


50 ore 0
10 ore
When there are obstructions on the inlet side and 0 e or
m
or
m
0
both lateral sides
0
5 or
m L H 50 ore
m
An obstruction or or
in the overhead
1 space 2 2. For series installation (more than two units)
1000 or more

s
s 10 les 10
les 0
mo or or 0
1000 or more

0o
r
re 50
0 1 2 mo or
50 re 10
0
mo or
re
10
0o
rm
L

1 1 ore
or 000 or 000
mo mo 25
re re 0o
or 250 rm
ore 0 0
mo ore 20 ore 30 ore
re m m
0
20 ore 0o
r or or
m
or 250 m
2
or 00 30 00 00
mo or mo 10 ore 10 ore
re re or
m L H or
m

Note : As for other patterns of installation, please refer to Installation manual or Engineering Data Book.
69
MEMO

70
Warning Ask a qualified installer or contractor to install this product. Do not try to install the product by yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the user's manual carefully before using this product. The user's manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gases, such as an acidic or alkaline gas, are produced.
2. When installing outdoor units in coastal areas, be sure to contact your local distributor and avoid direct exposure of the units to
sea breezes.

Specifications, designs and other content appearing in this brochure are current as of July 2017 but subject to change without notice.

c All rights reserved 07/17 SS