Download as pdf
Download as pdf
You are on page 1of 7
BXOG52 ASIPTRAR RA. a BCA Ww A EXPLOSION-PROOF [7""",,. DISTRIBUTION SPER: BOXES SERIES BXC1G52 XKO6-123-00181 3Git 1809001 MSR ERE ILE RUE a THE QUALITY GUARANTEE SYSTEM AUTHETICATION OF IS09001 fe Fl in BA DIRECTION HH 5 Ba HR EBL LA -a BRA ) ZHONGME! EXPLOSION-PROOF MOTOR & ELECTRICAL APPARATUS CO. , LTD th AR fe SHANDONG BOSHAN 1, GAG Application BXOGS2 RBM. BAL (ULF AH ARACEAE) $e GB3836.1~3-2000 CHEM HET ARRAGRSACRS) RENE RT. RRR BAT AAR, ET He HH BT MEE LR 2, RA, BL CR TI-~TA MEM SOHZ, WE LRH 220V, 380V. 66OV AMP, AMD. Bh he AVAL HH) ZO BX0G52 series explosion-proof power and lighting distribution boxes (Hereinafter called distribution box ) are designed and produced in accordance with GB3836.1~3-2000 “Electrical Apparatus for Explosive Gas Atmosphere ”. They are suitable to be used in places of zones I and 2 where there is explosive mixture which belongs to category II class A, B, C group TI~T4 for use of distributing and controlling in circuits with AC SOHZ, rated voltage 220V, 380V, 660V. 2. HB a ft Using Condition a) 7 it 2000m b) AM AMARART+40C, KR F-20T: c) MMS MM aE RAT 95% (E250 RL): d) CE HE HR PY A Ome Se BA Rh DT: e) EER Ray Mi ) EWMLASRBKA SM: g) FRAM HM, h) PREM IH. a) Altitude of the site of installation does not exceed 2000m; b) The ambient air temperature does not exceed +40°C, the lower limit of ambient air temperature is -20C; c) The relative humidity does not exceed 95% (at +25°C); 4) The place in which there is not gas or vapour which may corrode in sulation material; e) The place where there is not violent sway toss and vibration; f) The place where it doesn’t subject to rain and snow; g) The installation category does not exceed category Ill; h) The place in which the degree of pollution in the micro-environment does not exceed pollution degree 3. 3. BEREKSK. Type and data BxOGs}-00000-00000 »00G ot Explosion-proof’ 8 Box D-3)4) Power MUSE Lighting G-HE3t Wall ype ILHTE-S Code of design: FSH AH For marine 24 Ht No. Of cireuit SEAR Current of branch circuit ERSMRR Kind of circuit breaker CASN: CN CASAD: CA NCTOOH: NC Dz20: DZ | : HUME ERM 1, 2, 3 Technical data to see table 1, table 2, table 3 Table] EWS Technical data Li [ BRIE Stainless steel enclosure FLD ai Midale corrosion-proot Fo biaae Serious corrosion-proo? S-PAABEA. Waterproof Gndoor) Wb AR CURE Ourlet size we OA No. Of outlet / Direction D-EUI2 Top outer X-FUse Bottom outlet LEW Lef ou R458 Right outlet HL CUBER Inlet size 30779 Inlet direction D-Li82 Top inlet X-FHESR Bottom inlet HERO (ROARED No. OF iniet (Single inlet no-market) DVO RARE ite With master switch / rated current NEQAR No master switeh Outdoor | BER | emeee | poem ABH | mS ™ ae | ay | RT A crop | Mu i" | No.of . ‘ Kind of EPH | No ofoupne Type | TPO" | Rated | Ratedourentot | Curentor | EOE | poles a = [At | votage | maserciouit | branchcireit | 77 pxkoszis | a | <0 Ts 6 axons | S125 | 16.20.25 BXWC52-6 6__}220. 380, | <160__| 32. 40,50.) | IPavere D, - ACI, AC3 | 3P+PE+N BXWG52-8 8 660 $250 63, 80. | 3PAN+PE, BXRG52-10 10 —ais | 100. 150, BXwGS2-12 2 <400 #Table2 EELRSM Technical data aRKmeeR AD | Rated current of master switch, le<20 | 20<1e<20 | 40

You might also like