BXOG52 ASIPTRAR RA. a BCA
Ww A EXPLOSION-PROOF [7""",,. DISTRIBUTION
SPER:
BOXES SERIES BXC1G52
XKO6-123-00181
3Git 1809001 MSR ERE ILE RUE a
THE QUALITY GUARANTEE SYSTEM AUTHETICATION OF IS09001
fe Fl in BA
DIRECTION
HH 5 Ba HR EBL LA -a BRA )
ZHONGME! EXPLOSION-PROOF MOTOR & ELECTRICAL APPARATUS CO. , LTD
th AR fe
SHANDONG BOSHAN1, GAG
Application
BXOGS2 RBM. BAL (ULF AH ARACEAE) $e GB3836.1~3-2000 CHEM HET
ARRAGRSACRS) RENE RT. RRR BAT AAR, ET
He HH BT MEE LR 2, RA, BL CR TI-~TA MEM SOHZ,
WE LRH 220V, 380V. 66OV AMP, AMD. Bh he AVAL HH) ZO
BX0G52 series explosion-proof power and lighting distribution boxes (Hereinafter called
distribution box ) are designed and produced in accordance with GB3836.1~3-2000 “Electrical
Apparatus for Explosive Gas Atmosphere ”. They are suitable to be used in places of zones I and 2
where there is explosive mixture which belongs to category II class A, B, C group TI~T4 for use
of distributing and controlling in circuits with AC SOHZ, rated voltage 220V, 380V, 660V.
2. HB a ft
Using Condition
a) 7 it 2000m
b) AM AMARART+40C, KR F-20T:
c) MMS MM aE RAT 95% (E250 RL):
d) CE HE HR PY A Ome Se BA Rh DT:
e) EER Ray Mi
) EWMLASRBKA SM:
g) FRAM HM,
h) PREM IH.
a) Altitude of the site of installation does not exceed 2000m;
b) The ambient air temperature does not exceed +40°C, the lower limit of ambient air temperature
is -20C;
c) The relative humidity does not exceed 95% (at +25°C);
4) The place in which there is not gas or vapour which may corrode in sulation material;
e) The place where there is not violent sway toss and vibration;
f) The place where it doesn’t subject to rain and snow;
g) The installation category does not exceed category Ill;
h) The place in which the degree of pollution in the micro-environment does not exceed pollution
degree 3.
3. BEREKSK.
Type and dataBxOGs}-00000-00000 »00G
ot
Explosion-proof’
8 Box
D-3)4) Power
MUSE Lighting
G-HE3t Wall ype
ILHTE-S Code of design:
FSH
AH For marine
24 Ht No. Of cireuit
SEAR
Current of branch circuit
ERSMRR
Kind of circuit breaker
CASN: CN
CASAD: CA
NCTOOH: NC
Dz20: DZ |
:
HUME ERM 1, 2, 3
Technical data to see table 1, table 2, table 3
Table] EWS Technical data
Li
[ BRIE
Stainless steel enclosure
FLD ai
Midale corrosion-proot
Fo biaae
Serious corrosion-proo?
S-PAABEA. Waterproof Gndoor)
Wb
AR CURE Ourlet size
we OA
No. Of outlet / Direction
D-EUI2 Top outer
X-FUse Bottom outlet
LEW Lef ou
R458 Right outlet
HL CUBER Inlet size
30779 Inlet direction
D-Li82 Top inlet
X-FHESR Bottom inlet
HERO (ROARED
No. OF iniet (Single inlet no-market)
DVO RARE ite
With master switch / rated current
NEQAR
No master switeh
Outdoor
| BER | emeee | poem ABH |
mS ™ ae | ay | RT A crop | Mu
i" | No.of . ‘ Kind of EPH | No ofoupne
Type | TPO" | Rated | Ratedourentot | Curentor | EOE | poles a
= [At | votage | maserciouit | branchcireit | 77
pxkoszis | a | <0 Ts 6
axons | S125 | 16.20.25
BXWC52-6 6__}220. 380, | <160__| 32. 40,50.) | IPavere
D, - ACI, AC3 | 3P+PE+N
BXWG52-8 8 660 $250 63, 80. | 3PAN+PE,
BXRG52-10 10 —ais | 100. 150,
BXwGS2-12 2 <400#Table2 EELRSM Technical data
aRKmeeR AD |
Rated current of master switch,
le<20 | 20<1e<20 | 40