Leuze electronic

96 Series
Product description
Leuze electronic

Contents:
96 Series - Overview and advantages
Special features of Series 96
Sensor selection table
Data sheets

© All rights reserved, especially the rights of copying and translation. Copying or reproduction in any form requires
prior written permission from Leuze electronic GmbH & Co. KG
Subject to changes due to technical progress.
Leuze electronic

96 Series
Overview and advantages

Extensive sensor series:


- In robust metal housing with glass optics
- In solid plastic housing
- In protection class IP 67

Operating principles:
- Throughbeam photoelectric sensors to 150m
- Protective throughbeam photoelectric sensors to 60m
- Retro-reflective photoelectric sensors with polarisation
filter
- Energetic diffuse reflection light scanners
- Diffuse reflection light scanners with background
suppression
- Retro-reflective photoelectric sensor for safe detection
of transparent media
- Laser diffuse reflection light scanners with background
suppression to 5m (15m against reflective tape)

- Visible red light for easy alignment


- Infrared light for high performance reserve and to
prevent interference from extraneous light

- 10 … 30VDC voltage with PNP/NPN transistor output


- Alternatively AS-interface bus connection or
20 … 230V all mains voltage with relay output
New!!!
- Sensors with complementary switching outputs
M12 connector or comfortable terminal compartment for - A2LS ensures high extraneous light protection
individual electrical connection
- Sensors for direct connection to AS-interface
I/O coupling modules
- Sensors in accordance with ATEX standard
Innovative mounting systems for rod mounting or through - Light/dark switching for variable signal output
holes for universal screw mounting

Extensive options:
- Warning output
- Activation input
- Switching delay
- Low temperature and optics heating down to -35°C
- Wide angle

–1–
Leuze electronic

Special features of Series 96

At home in all branches of industry under all


environmental conditions:
- Sensors for standard and special - Front-window heating for use under
applications extreme environmental conditions
- Housings in metal and plastic - Versatile mounting systems make
versions possible timesaving and cost-
- Standard M12 connection or more effective, onsite mounting
convenient, easily assessable
terminal compartment
- Sensors with integrated AS-interface
technology

Throughbeam photoelectric sensors


 Advantage 1: Various operating ranges, each with a high performance reserve
A2 LS  Advantage 2: Sensitivity adjustment for adaptation to the application
 Advantage 3: Warning output for display of soiling and misalignment
 Advantage 4: Versions in infrared and visible red light
 Advantage 5: Wide angle version for mounting in difficult-to-access areas

Protective throughbeam photoelectric sensors


 Advantage 1: Versions in infrared and visible red light
 Advantage 2: Display of operational readiness and status of the switching output

Retro-reflective photoelectric sensors


 Advantage 1: Large operating range
A2 LS  Advantage 2: Invisible infrared light

Retro-reflective photoelectric sensors with polarisation filter


 Advantage 1: Large operating range with high performance reserve
A2 LS  Advantage 2: Adjustable sensitivity
 Advantage 3: Status LED with flashing mode for display of soiling and misalignment
 Advantage 4: Activation input for function test and muting application

Retro-reflective photoelectric sensors for detection of transparent media, e.g. bottles


(glass, PET)
A2 LS  Advantage 1: Large operating range
 Advantage 2: Exact adjustment for objects with a wide range of transmittances
 Advantage 3: Timesaving adjustment through user guidance
 Advantage 4: Adjustment possible without object
 Advantage 5: Gap detection

–2–
Leuze electronic

Universally usable optical sensors for all


branches of industry

Energetic diffuse reflection light scanners


 Advantage 1: Sensitivity adjustment by means of adjustment potentiometer
A2 LS  Advantage 2: Large scanning range with minimal zero distance
 Advantage 3: Multiple options such as switching delay, optics heating, etc.

Diffuse reflection light scanners with background suppression


 Advantage 1: Versions in infrared and visible red light
A2 LS  Advantage 2: Very good detection behaviour even with shiny surfaces
 Advantage 3: Safe switching behaviour in the set switching point
 Advantage 4: Diagnosis and programming options for timesaving commissioning and adaptation to
various environmental conditions

Laser scanners with background suppression


 Advantage 1: Large scanning and adjustment range
 Advantage 2: 2 or 3 individually adjustable switching points
 Advantage 3: Safe detection of shiny and slanted surfaces
 Advantage 4: Very good background and extraneous light suppression through the use of the phase-
measurement principle
 Advantage 5: Light spot and switching behaviour suitable for positioning at long distance

Other 96 Series products (separate documents):

Measuring (laser) distance sensors ODS(L) 96

Ex Sensors LS 96 Ex, SLS 96 Ex, PRK 96 Ex, HRT 96 Ex

–3–
Leuze electronic
Sensor selection table

Operating Designation Typ. oper. range limit/ Housing Light source Operating voltage Output
principle UL typ. scan. range limit
C US
LISTED

20 … 230VAC/DC

NPN transistor
PNP transistor
10 … 30VDC

AS-interface
AS-i system
Red light

Infrared
Plastic

Relay
Metal
LS 96M/P-1040-4 • 65m • • • •
LS 96M/P-1130-2 • 65m • • • •
LS 96M/P-1170-2 • 39m • • • •
LS 96M/P-1170-4 • 39m • • • •
LS 96M/N-1010-2 • 65m • • • •
LS 96K/P-1010-4 • 65m • • • •
LS 96K/P-1030-2 • 65m • • • •
LS 96K/P-1030-4 • 65m • • • •
LS 96K/P-1140-2 3) • 39m • • • •
LS 96K/P-1015-4 4) • 65m • • • •
LS 96K/P-1010.1-4 4) • 65m • • • •

LS 96M/P-3010-4 • 150m • • • •
LS 96M/P-3010-2 • 150m • • • •
LS 96M/P-3012-2 • 150m • • • •
LS 96M/P-3012-4 • 150m • • • •

LS 96M/P-181W-4 • 39m • • • •
LS 96M/P-181W-2 • 39m • • • •
LS 96M/P-1816-4 • 39m • • • •

LS 96M/R-1310-2 • 65m • • • •
LS 96K/R-1310-2 • 65m • • • •
LS 96K/R-1320-2 • 65m • • • •
LS 96K/R-131P-2 • 65m • • • •
LS 96M/R-3310-2 • 150m • • • •

LS 96M/R-176W-2 39m • • • •

SLS 96M/P-1070-T2-2 • 65m • • • •


SLS 96M/P-1070-T2-4 • 65m • • • •
SLS 96M/P-1200-T2-2 • 39m • • • •
SLS 96M/P-1200-T2-4 • 39m • • • •
SLS 96M/P-1071-T2-2 • 65m • • • •
SLS 96M/P-1071-T2-4 • 65m • • • •
SLS 96K/P-1070-T2-2 • 65m • • • •
SLS 96K/P-1070-T2-4 • 65m • • • •
SLS 96K/P-1200-T2-2 • 39m • • • •
SLS 96K/P-1200-T2-4 • 39m • • • •
SLS 96K/P-1207-T2-2 2) • 39m • • • •
SLS 96K/P-1207-T2-4 2) • 39m • • • •

LS 96M/A-182W-4 1) • 39m • • • •

1) Transmitter without integrated AS-i-slave technology


2) Suitable for multi-sensor operation (parallel light axes)
3) Activation input LOW (active low)
4) For direct connection to AS-interface I/O coupling modules

–4–
Leuze electronic

Switching Switching Connection Options Page


frequency

Low temp./optics heating


Background suppression

Transparent media
Safety application
Polarisation filter

Switching delay
Warning output

Activation input
M12 connector

Wide angle
Terminals
Light

Dark

500Hz • • • • • 11
500Hz • • • • • • • 11
500Hz • • • • • 11
500Hz • • • • • 11
500Hz • • • 11
500Hz • • • 13
500Hz • • • • 13
500Hz • • • • 13
500Hz • • • • 13
500Hz • • 13
500Hz • • • 13

500Hz • • • 15
500Hz • • • 15
500Hz • • • • • 15
500Hz • • • • • 15

500Hz • • • • 17
500Hz • • • • 17
500Hz • • • • 17

20Hz • • • 19
20Hz • • • 19
20Hz • • • • 19
20Hz • • • 19
20Hz • • • • 19

20Hz • • • • 21

500Hz • • • 23
500Hz • • • 23
500Hz • • • • 23
500Hz • • • • 23
500Hz • • • • • 23
500Hz • • • • • 23
500Hz • • • • 25
500Hz • • • • 25
500Hz • • • • 25
500Hz • • • • 25
500Hz • • • • 25
500Hz • • • • 25

500Hz/AS-i • • • • • 27

–5–
Leuze electronic

Operating Designation Typ. oper. range limit/ Housing Light source Operating voltage Output
principle UL typ. scan. range limit
C US
LISTED

20 … 230VAC/DC

NPN transistor
PNP transistor
10 … 30VDC

AS-interface
AS-i system
Red light

Infrared
Plastic

Relay
Metal
RK 96M/P-1440-21 • 18m • • • •

RK 96K/R-1560-25 • 18m • • • •
RK 96K/R-156P-25 • 18m • • • •

PRK 96M/P-1370-22 • 10m • • • •


PRK 96M/P-1370-42 • 10m • • • •
PRK 96M/P-1400-22 • 10m • • • •
PRK 96M/P-1400-42 • 10m • • • •
PRK 96M/P-1361.1-47 • 10m • • • •
PRK 96M/P-3380-41 • 18m • • • •
PRK 96M/P-3360-21 • 18m • • • •
PRK 96M/N-3366-27 • 18m • • • •

PRK 96K/P-1360-21 • 10m • • • •


PRK 96K/P-1360-41 • 10m • • • •
PRK 96K/P-1380-21 • 10m • • • •
PRK 96K/P-1380-41 • 10m • • • •
PRK 96K/P-3368-41 • 28m • • • •
PRK 96K/P-1365-45 3) • 10m • • • •
PRK 96K/P-1360.1-41 3) • 10m • • • •
PRK 96K/N-1380-46 • 10m • • • •

PRK 96M/P-1362-47 • 10m • • • •


PRK 96M/P-1361-47 • 10m • • • •
PRK 96K/P-1363-29 1) • 10m • • • •
PRK 96K/P-1361-29 • 10m • • • •

PRK 96M/R-3420-25 18m • • • •


PRK 96M/R-3430-25 18m • • • •

PRK 96K/R-1420-25 • 10m • • • •


PRK 96K/R-1430-25 • 10m • • • •
PRK 96K/R-3428-25 24m • • • •

PRK 96M/P-1830-21 2) • 1.85m • • • •


PRK 96M/P-1830-41 2) • 1.85m • • • •

PRK 96M/R-1850-25 2) • 1.85m • • • •

PRK 96M/P-1838-21 • 8.5m • • • •


PRK 96M/P-1838-41 • 8.5m • • • •

PRK 96M/R-1858-25 • 8.5m • • • •

PRK 96M/A-3410-44 • 18m • • • •

PRK 96M/P-2838-28 • 8.5m • • • •


PRK 96M/P-2838-48 8.5m • • • •

1) Active low
2) Gap detection
3) For direct connection to AS-interface I/O coupling modules

–6–
Leuze electronic

Switching Switching Connection Options Page


frequency

Low temp./optics heating


Background suppression

Transparent media
Safety application
Polarisation filter

Switching delay
Warning output

Activation input
M12 connector

Single lens
Terminals
Light

Dark

1000Hz • • • 29

20Hz • • • 31
20Hz • • • 31

1000Hz • • • • 33
1000Hz • • • • 33
1000Hz • • • • • • 33
1000Hz • • • • • • 33
1000Hz • • • • • 33
1000Hz • • • • • 33
1000Hz • • • • 33
1000Hz • • • • • 33

1000Hz • • • • 35
1000Hz • • • • 35
1000Hz • • • • • 35
1000Hz • • • • • 35
1000Hz • • • • 35
1000Hz • • • 35
1000Hz • • • • 35
1000Hz • • • • • 35

1000Hz • • • • • • 37
1000Hz • • • • • 37
1000Hz • • • • • 37
1000Hz • • • • • 37

20Hz • • • • 39
20Hz • • • • • 39

20Hz • • • • 41
20Hz • • • • • 41
20Hz • • • 41

1000Hz • • • • • • 43
1000Hz • • • • • • 43

20Hz • • • • • • • 45

1000Hz • • • • • • 47
1000Hz • • • • • • 47

20Hz • • • • • • 49

1000Hz/AS-i • • • • • 51

500Hz • • • • • • 53
500Hz • • • • • • 53

–7–
Leuze electronic

Operating Designation Typ. oper. range limit/ Housing Light source Operating voltage Output
principle UL typ. scan. range limit
C US
LISTED

20 … 230VAC/DC

NPN transistor
PNP transistor
10 … 30VDC

AS-interface
AS-i system
Red light

Infrared
Plastic

Relay
Metal
RT 96M/P-1374-500-42 • 0.03 … 0.7m • • • •
RT 96M/P-1474-800-42 • 0.02 … 1.2m • • • •

RT 96K/P-1444-800-21 • 0.02 … 1.2m • • • •


RT 96K/P-1444-800-41 • 0.02 … 1.2m • • • •
RT 96K/N-1444-800-46 • 0.02 … 1.2m • • • •
RT 96K/P-1444.1-800-41 5) • 0.02 … 1.2m • • • •

RT 96M/R-1574-800-25 • 0.02 … 1.2m • • • •

HRT 96M/P-1630-800-41 • 0.1 … 1.2m • • • •


HRT 96M/P-1636-800-41 • 0.1 … 1.2m • • • •
HRT 96M/P-1640-800-21 • 0.1 … 1.2m • • • •
HRT 96M/P-1640-800-41 • 0.1 … 1.2m • • • •
HRT 96M/P-1635-800-45 5) • 0.1 … 1.2m • • • •
HRT 96M/P-1610-1200-21 • 0.1 … 1.8m • • • •
HRT 96M/P-1610-1200-41 • 0.1 … 1.8m • • • •
HRT 96M/P-1620-1200-21 • 0.1 … 1.8m • • • •
HRT 96M/P-1620-1200-41 • 0.1 … 1.8m • • • •
HRT 96M/N-1606-1200-27 • 0.1 … 1.8m • • • •

HRT 96K/P-1600-1200-21 • 1.8m • • • •


HRT 96K/P-1600-1200-41 • 1.8m • • • •
HRT 96K/P-1630-800-21 • 1.2m • • • •
HRT 96K/P-1630-800-41 • 1.2m • • • •
HRT 96K/P-1631-800-47 • 1.2m • • • •
HRT 96K/P-1640-800-41 • 1.2m • • • •
HRT 96K/P-1605-1200-45 5) • 1.8m • • • •
HRT 96K/P-1607-1200-49 5) • 1.8m • • • •
HRT 96K/P-1600.1-1200-41 5) • 1.8m • • • •

HRT 96M/R-1680-1200-25 • 1.8m • • • •


HRT 96M/R-1690-1200-25 • 1.8m • • • •
HRT 96K/R-1680-1200-25 • 1.8m • • • •
HRT 96K/R-1690-1200-25 • 1.8m • • • •
HRT 96M/R-1689-1200-25 • 1.8m • • • •

HRT 96M/A-1660-1200-44 • 1.8m • • • •


HRT 96M/A-1670-800-44 • 1.2m • • • •

HRT 96M/P-1600-2000-42 1) • 0.10 … 2.5m • • • •


HRT 96M/P-3604-2000-42 2) • 0.01 … 2.5m • • • •

HRT 96M/P-3360-5000-426 3) 5.5m • • • •


HRT 96M/P-3370-5000-436 4) 5.5m • • • •
HRT 96M/P-3375-5000-436 4) 5.5m • • • •

HRT 96M/P-336W.21-5000-426 3) 2.5m/5.0m • • • •

HRT 96M/P-3360-2500-426 3) 2.5m • • • •


1) 1 Switching point / switching output
2) 2 Switching points / switching outputs, short range
3) 2 Switching points / switching outputs, 1 analogue output
4) 3 Switching points / switching outputs
5) For direct connection to AS-interface I/O coupling modules

–8–
Leuze electronic

Switching Switching Connection Options Page


frequency

Low temp./optics heating


Background suppression

Safety application
Polarisation filter

Switching delay
Warning output

Activation input
M12 connector

M18 connector

Terminals
Light

Dark

1000Hz • • • 55
1000Hz • • • • 55

1000Hz • • • 57
1000Hz • • • 57
1000Hz • • • 57
1000Hz • • • 57

20Hz • • • • 59

300Hz • • • • 61
300Hz • • • • • 61
300Hz • • • • • 61
300Hz • • • • • 61
300Hz • • • • 61
300Hz • • • • • 61
300Hz • • • • • 61
300Hz • • • • • • 61
300Hz • • • • • • 61
300Hz • • • • • 61

300Hz • • • • 63
300Hz • • • • 63
300Hz • • • • 63
300Hz • • • • 63
300Hz • • • • • 63
300Hz • • • • • 63
300Hz • • • 63
300Hz • • • 63
300Hz • • • • 63

20Hz • • • • 65
20Hz • • • • • 65
20Hz • • • • 65
20Hz • • • • • 65
20Hz • • • • 65

300Hz/AS-i • • • • • 67
300Hz/AS-i • • • • • 67

300Hz • • • • • 69
300Hz • • • • • 69

20Hz • • • • 71
20Hz • • • • 71
20Hz • • • 71

10Hz • • • • 73

40Hz • • • • 75

–9–
Specifications and description
Leuze electronic
LS 96 Throughbeam photoelectric sensors
Dimensioned drawing

39m
65m

10 - 30 V
DC
A2 LS

! Throughbeam photoelectric sensors with


high performance reserve in visible red light
or infrared light
! Robust metal housing with glass cover or
plastic housing, protection class IP 67/
IP 69K for industrial application
A Indicator diode green
! Complementary outputs, sensitivity B Indicator diode yellow
adjustment and delay before start-up for C Optical axis
optimal adaptation to the application D Device plug M12x1
! Connection via M12 connector or terminal E Device plug M18x1
compartment F Screwed cable gland M16x1.5 for Ø 5 … 10mm
! Multiple options with warning output, G Countersinking for SK nut M5, 4.2 deep
activation input, switching delays and optics H Connection terminals
heating for use at low temperatures I Cable entry
K Sensitivity adjustment

Electrical connection
ISO C UL US
We reserve the right to make changes • 96_a01e.fm

9001 LISTED

IP 69K
IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! M12 connectors (KD …)
! Ready-made cables (K-D …)
! Alignment aid ARH 96

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 LS 96 M/P… - 08
www.leuze.de

– 10 –
Leuze electronic
LS 96
Specifications Tables
Optical data Infrared light Red light Red light
Typ. operating range limit 1) 0 … 65m 0 … 39m 0 30 39
Operating range 2) 0 … 50m 0 … 30m
Infrared light
Light source LED (modulated light) LED (modulated light)
Wavelength 880nm 660nm 0 50 65

Timing Operating range [m]


Switching frequency 500Hz Typ. operating range limit [m]
Response time 1ms
Delay before start-up ≤ 200ms
Electrical data
Operating voltage UB 10 … 30VDC (incl. residual ripple)
Residual ripple ≤ 15% of UB
Bias current ≤ 50mA, ≤ 130mA with optional optics heating
Switching output NPN or PNP transistor
Function characteristics light/dark switching
Signal voltage high/low ≥ (UB -2V)/≤ 2V (PNP) Diagrams
Output current max. 100mA
Sensitivity adjustable Red light
Typ. response behaviour
Indicators 400
LED green ready

Misalignment y [mm]
300
LED yellow light path free 200
LED yellow flashing light path free, no performance reserve 100
y2

Mechanical data Metal housing 0


Housing diecast zinc -100
y1
Optics cover glass -200
Weight 380g -300
Connection type terminals or M12 connector -400
0 5 10 15 20 25 30 35 40 45 50
Environmental data Distance x [m]
Ambient temp. (operation/storage) -20°C … +60°C/-40°C … +70°C
Protective circuit 3) 1, 2, 3 Infrared light
VDE safety class 4) II, all-insulated Typ. response behaviour
Protection class IP 67, IP 69K 5) 1,0
0,8
LED class 1 (acc. to EN 60825-1) y2

Misalignment y [m]
0,6
Standards applied IEC 60947-5-2 0,4
0,2
Options 0
Activation input activ -0,2
Transmitter active/not active ≥ 8V/≤ 2V (≥ 2V/≤ 2V) 6) -0,4
Activation/disable delay ≤ 0.5ms -0,6
y1
Input resistance 47KΩ ± 10% -0,8
-1,0
Warning output autoControl warn PNP transistor, 100mA, counting principle 0 10 20 30 40 50 60 70
Optics heating for temperature changes, prevents fogging Distance x [m]
Low temperature to -35°C
Switching delay (slow oper./release) 0 … 10s (separately adjustable) y2
y1
1) Typ. operating range limit: max. attainable range without performance reserve
2) Operating range: recommended range with performance reserve x
3) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs
4) Rating voltage 250VAC
5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,
acids and bases are not part of the test
6) Active high

Order guide Remarks


! The throughbeam photoe-
Part No. 500 25205 (Re)

Part No. 500 25201 (Re)

Part No. 500 25195 (Re)

Part No. 500 25197 (Re)

Part No. 500 31295 (Re)

Selection table
Part No. 500 25228 (Tr)

Part No. 500 25223 (Tr)

Part No. 500 25217 (Tr)

Part No. 500 25219 (Tr)

Part No. 500 25225 (Tr)

lectric sensor is also


available with integrated
LS 96M/N-1010-2
LS 96M/P-1040-4

LS 96M/P-1130-2

LS 96M/P-1170-2

LS 96M/P-1170-4

AS-i chip for direct con-


Order code "
nection to the AS-i system.

Equipment #
Housing metal ! ! ! ! !
plastic
Light source red light (30m) ! !
infrared light (50m) ! ! !
Connection terminals ! ! !
M12 connector ! !
Features optics heating/low temp. !
switching delay ! ! ! !
warning output ! ! ! !
activation input ! 6)
NPN switching output !
LS 96 M/P… - 08 0603

– 11 –
Leuze electronic
LS 96 Throughbeam photoelectric sensors
Dimensioned drawing

39m
65m

10 - 30 V
DC
A2 LS

! Throughbeam photoelectric sensors with


high performance reserve in visible red light
or infrared light
! Robust metal housing with glass cover or
plastic housing, protection class IP 67 for
industrial application
A Indicator diode green
! Complementary outputs for standard appli- B Indicator diode yellow
cations and a wide range of input and output C Optical axis
variants for optimum adaptation to the D Device plug M12x1
application E Device plug M18x1
! Multiple options with warning output, F Screwed cable gland M16x1.5 for Ø 5 … 10mm
activation input, switching delays and optics G Countersinking for SK nut M5, 4.2 deep
heating for use at low temperatures H Connection terminals
I Cable entry
K Sensitivity adjustment

Electrical connection
ISO C UL US
9001 LISTED
We reserve the right to make changes • 96_a11e.fm

IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! M12 connectors (KD …)
! Ready-made cables (K-D …)
! Alignment aid ARH 96

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 LS 96 K/P… - 09
www.leuze.de

– 12 –
Leuze electronic
LS 96
Specifications Tables
Optical data Infrared light Red light Red light
Typ. operating range limit 1) 0 … 65m 0 … 39m 0 30 39
Operating range 2) 0 … 50m 0 … 30m
Infrared light
Light source LED (modulated light) LED (modulated light)
Wavelength 880nm 660nm 0 50 65

Timing Operating range [m]


Switching frequency 500Hz Typ. operating range limit [m]
Response time 1ms
Delay before start-up ≤ 200ms
Electrical data
Operating voltage UB 10 … 30VDC (incl. residual ripple)
Residual ripple ≤ 15% of UB
Bias current ≤ 50mA, ≤ 130mA with optional optics heating
Switching output NPN or PNP transistor
Function characteristics light/dark switching
Signal voltage high/low ≥ (UB -2V)/≤ 2V (PNP) Diagrams
Output current max. 100mA
Sensitivity adjustable Red light
Typ. response behaviour
Indicators
LED green ready 400
LED yellow light path free 300

Misalignment y [m]
LED yellow flashing light path free, no performance reserve 200
y2
100
Mechanical data Plastic housing 0
Housing polycarbonate -100
Optics cover plastic -200
y1

Weight 150g -300


Connection type terminals or M12 connector -400
0 5 10 15 20 25 30 35 40 45 50
Environmental data Distance x [m]
Ambient temp. (operation/storage) -20°C … +60°C/-40°C … +70°C
Protective circuit 3) 1, 2, 3 Infrared light
VDE safety class 4) II, all-insulated Typ. response behaviour
Protection class IP 67 1,0
LED class 1 (acc. to EN 60825-1) 0,8
y2

Misalignment y [m]
Standards applied IEC 60947-5-2 0,6
0,4
Options 0,2
Activation input activ 0
Transmitter active/not active ≤ 2V/≥ 8V 5) -0,2
Activation/disable delay ≤ 0.5ms -0,4
-0,6
Input resistance 47KΩ ± 10% -0,8
y1

Warning output autoControl warn PNP transistor, 100mA, counting principle -1,0
0 10 20 30 40 50 60 70
Optics heating for temperature changes, prevents fogging Distance x [m]
Low temperature to -35°C
Switching delay (slow oper./release) 0 … 10s (separately adjustable)
y2
1) Typ. operating range limit: max. attainable range without performance reserve y1
2) Operating range: recommended range with performance reserve
x
3) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs
4) Rating voltage 250VAC
5) Active low

Order guide
Remarks
Part No. 500 25258 (Re)

Part No. 500 25259 (Re)

Part No. 500 80483 (Re)

Part No. 500 31295 (Re)

Part No. 501 03004 (Re)

Part No. 501 03218 (Re)

Selection table
Part No. 500 25254 (Tr)

Part No. 500 25255 (Tr)

Part No. 500 25254 (Tr)

Part No. 500 80657 (Tr)

Part No. 500 25254 (Tr)

Part No. 500 25254 (Tr)

! The throughbeam photoe-


LS 96K/P-1010.1-4

lectric sensor is also


LS 96K/P-1010-4

LS 96K/P-1030-2

LS 96K/P-1030-4

LS 96K/P-1140-2

LS 96K/P-1015-4

Order code " available with integrated


AS-i chip for direct con-
nection to the AS-i system.
Equipment # ! *For direct connection to
AS-i I/O coupling modules
Housing metal (LS 96K/P-1015-4 and
plastic ! ! ! ! ! ! LS 96K/P-1010.1-4)
Light source red light (30m) !
infrared light (50m) ! ! ! ! !
Connection terminals ! !
M12 connector ! ! ! !
Features switching delay ! !
warning output
activation input ! 5)
PIN 2 = NC * ! !
PIN 4 = dark switching !
PIN 4 = light/dark reversible !

LS 96 K/P… - 09 0603

– 13 –
Leuze electronic
LS 96 Throughbeam photoelectric sensors
Dimensioned drawing

150m

10 - 30 V
DC
A2 LS

! Throughbeam photoelectric sensors with


high performance reserve in infrared light
! Robust metal housing with glass cover, pro-
tection class IP 67/IP 69K for industrial
application
! Complementary outputs, sensitivity
adjustment and delay before start-up for
optimal adaptation to the application A Indicator diode green
! Connection via M12 connector or terminal B Indicator diode yellow
compartment C Optical axis
D Device plug M12x1
! Multiple options with warning output,
E Screwed cable gland M16x1.5 for Ø 5 … 10mm
activation input, switching delays and optics
F Countersinking for SK nut M5, 4.2 deep
heating for use at low temperatures
G Connection terminals
H Cable entry
I Sensitivity adjustment

Electrical connection
ISO C UL US
9001 LISTED
Transmitter Receiver
We reserve the right to make changes • 96_a02e.fm

IP 69K
IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! M12 connectors (KD …)
! Ready-made cables (K-D …)
! Alignment aid ARH 96

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 LS 96 M/P-3010-2/4 - 06
www.leuze.de LS 96 M/P-3012-2 - 06

– 14 –
Leuze electronic
LS 96
Specifications Tables
0 120 150
Optical data Infrared light
Typ. operating range limit 1) 0 … 150m
Operating range [m]
Operating range 2) 0 … 120m
Light source LED (modulated light) Typ. operating range limit [m]
Wavelength 880nm
Timing
Switching frequency 500Hz
Response time 1ms
Delay before start-up ≤ 200ms
Electrical data
Operating voltage UB 10 … 30VDC (incl. residual ripple)
Residual ripple ≤ 15% of UB
Bias current ≤ 50mA, ≤ 130mA with optional optics heating
Switching output PNP transistor
Function characteristics light/dark switching
Signal voltage high/low ≥ (UB -2V)/≤ 2V (PNP)
Output current max. 100mA
Sensitivity adjustable
Indicators
LED green ready
LED yellow light path free
LED yellow flashing light path free, no performance reserve
Mechanical data Metal housing
Housing diecast zinc
Optics cover glass
Weight 380g Diagrams
Connection type terminals, M12 connector Typ. response behaviour
Environmental data 3,5
Ambient temp. (operation/storage) -20°C … +60°C/-40°C … +70°C 2,5

Misalignment y [m]
Protective circuit 3) 1, 2, 3 1,5
y2
VDE safety class 4) II, all-insulated
0,5
Protection class IP 67, IP 69K 5) 0
LED class 1 (acc. to EN 60825-1) -0,5
Standards applied IEC 60947-5-2 -1,5
y1
Options -2,5
Activation input activ -3,5
Transmitter active/not active ≥ 8V/≤ 2V (≥ 2V/≤ 2V) 6) 0 20 40 60 80 100 120 140 160

Activation/disable delay ≤ 0.5ms Distance x [m]


Input resistance 47KΩ ± 10%
y2
Warning output autoControl warn PNP transistor, 100mA, counting principle
y1
Optics heating for temperature changes, prevents fogging
Low temperature to -35°C x
Switching delay (slow oper./release) 0 … 10s (separately adjustable)
1) Typ. operating range limit: max. attainable range without performance reserve
2) Operating range: recommended range with performance reserve
3) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs
4) Rating voltage 250VAC
5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,
acids and bases are not part of the test
6) Active high

Order guide Remarks


Part No. 500 34128 (Re)

Part No. 500 34128 (Re)

Part No. 500 33328 (Re)

Part No. 501 03291 (Re)

Selection table
Part No. 500 25225 (Tr)

Part No. 500 25228 (Tr)

Part No. 500 25223 (Tr)

Part No. 501 03290 (Tr)

LS = Pair consisting of
LSS = Transmitter
LSE = Receiver
LS 96M/P-3010-2

LS 96M/P-3010-4

LS 96M/P-3012-2

LS 96M/P-3012-4

Order code " LS 96M/P-3010-2


LSS 96M-1070-23
LSE 96M/P-3010-21
Equipment # LS 96M/P-3010-4
Housing metal ! ! ! ! LSS 96M-1070-43
Light source infrared light (120m) ! ! ! ! LSE 96M/P-3010-41
Connection terminals ! ! LS 96M/P-3012-2
M12 connector ! ! LSS 96M-1090-24
LSE 96M/P-3012-21
Features optics heating/low temp. ! !
activation input ! 6) ! 6) LS 96M/P-3012-4
LSS 96M-1090-43
LSE 96M/P-3012-41

LS 96 M/P-3010-2/4 - 06 0603
LS 96 M/P-3012-2 - 06

– 15 –
Leuze electronic
LS 96 Throughbeam photoelectric sensors
Dimensioned drawing

39m

10 - 30 V
DC
A2 LS

! Powerful throughbeam photoelectric sen-


sors with performance reserve in visible red
light
! Wide angle version for easy alignment
! Robust metal housing with glass cover, pro-
tection class IP 67/IP 69K for industrial
application
! Complementary outputs, sensitivity A Indicator diode green
adjustment and delay before start-up for B Indicator diode yellow
optimal adaptation to the application C Optical axis
! Connection via M12 connector or comforta- D Device plug M12x1
ble terminal compartment up to 1.5mm2 E Screwed cable gland M16x1.5 for Ø 5 … 10mm
F Countersinking for SK nut M5, 4.2 deep
G Connection terminals
H Cable entry
I Sensitivity adjustment

Electrical connection
ISO C UL US
9001 LISTED
Transmitter Receiver
We reserve the right to make changes • 96_a03e.fm

IP 69K
IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! M12 connectors (KD …)
! Ready-made cables (K-D …)
! Alignment aid ARH 96

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 LS 96 M/P-181W-4/2 - 05
www.leuze.de LS 96 M/P-1816-4 - 05

– 16 –
Leuze electronic
LS 96
Specifications Tables
0 30 39
Optical data Red light
Typ. operating range limit 1) 0 … 39m
Operating range [m]
Operating range 2) 0 … 30m
Light source LED (modulated light) Typ. operating range limit [m]
Wavelength 660nm
Timing
Switching frequency 500Hz
Response time 1ms
Delay before start-up ≤ 200ms
Electrical data
Operating voltage UB 10 … 30VDC (incl. residual ripple)
Residual ripple ≤ 15% of UB
Bias current ≤ 50mA
Switching output PNP transistor
Function characteristics light/dark switching
Signal voltage high/low ≥ (UB -2V)/≤ 2V (PNP)
Output current max. 100mA
Sensitivity adjustable
Indicators
LED green ready Diagrams
LED yellow light path free Typ. response behaviour
LED yellow flashing light path free, no performance reserve
400
Mechanical data Metal housing

Misalignment y [mm]
300
Housing diecast zinc 200
y2
Optics cover glass 100
Weight 380g 0
Connection type terminals, M12 connector -100
y1
-200
Environmental data -300
Ambient temp. (operation/storage) -20°C … +60°C/-40°C … +70°C -400
Protective circuit 3) 1, 2, 3 0 5 10 15 20 25 30 35 40 45 50
VDE safety class 4) II, all-insulated Distance x [m]
Protection class IP 67, IP 69K 5)
LED class 1 (acc. to EN 60825-1) y2
Standards applied IEC 60947-5-2 y1

1) Typ. operating range limit: max. attainable range without performance reserve x
2) Operating range: recommended range with performance reserve
3) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs
4) Rating voltage 250VAC
5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,
acids and bases are not part of the test

Remarks
! Angle at a distance of 3m:
transmitter:
angle of radiation typ. 10°
receiver:
receiving angle typ. 12°

Order guide LS = Pair consisting of


LSS = Transmitter
Part No. 500 31575 (Re)

Part No. 500 32741 (Re)

Part No. 500 32128 (Re)

Selection table LSE = Receiver


Part No. 500 31574 (Tr)

Part No. 500 32835 (Tr)

Part No. 500 32129 (Tr)


LS 96M/P-181W-4

LS 96M/P-181W-2

LS 96M/P-181W-4
LS 96M/P-1816-4

Order code " LSS 96M-120W-43


LSE 96M/P-181W-41
LS 96M/P-181W-2
Equipment # LSS 96M-120W-23
LSE 96M/P-181W-21
Housing metal ! ! !
LS 96M/P-1816-4
Light source red light (30m) ! ! !
LSS 96M-1206-43
Connection terminals ! LSE 96M/P-1816-41
M12 connector ! !
Features fixed sensitivity setting ! ! !
optics heating/low temp. !

LS 96 M/P-181W-4/2 - 05 0603
LS 96 M/P-1816-4 - 05

– 17 –
Leuze electronic
LS 96 Throughbeam photoelectric sensors
Dimensioned drawing

65m
150m

20-230 V
AC / DC
A2 LS

! Throughbeam photoelectric sensors with


high performance reserve in infrared light
! Robust metal housing with glass cover or
plastic housing, protection class IP 67/
IP 69K for industrial application
! All-mains design 20 … 230VAC/DC
! Relay with change-over contact, sensitivity
adjustment and delay before start-up for A Indicator diode green
optimal adaptation to the application B Indicator diode yellow
C Optical axis
! Connection via comfortable terminal com-
D Screwed cable gland M16x1.5 for Ø 5 … 10mm
partment up to 1.5mm2
E Countersinking for SK nut M5, 4.2 deep
! Version with additional switching delay F Connection terminals
G Cable entry
H Sensitivity adjustment

Electrical connection (example)


ISO C UL US
9001 LISTED
We reserve the right to make changes • 96_a05e.fm

Transmitter

IP 69K
IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
Receiver
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! Spark extinction
! Alignment aid ARH 96

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 LS 96 K/R… - 09
www.leuze.de LS 96 M/R… - 09

– 18 –
Leuze electronic
LS 96
Specifications Tables
Optical data 65m 150m 65m models
Typ. operating range limit 1) 0 … 65m 0 … 150m 0 50 65
Operating range 2) 0 … 50m 0 … 120m
150m models
Light source LED (modulated light)
Wavelength 880nm (infrared) 0 120 150

Timing Operating range [m]


Switching frequency 20Hz Typ. operating range limit [m]
Response time 25ms
Delay before start-up ≤ 200ms
Electrical data
Operating voltage UB 20 … 230VAC, 50/60Hz Diagrams
20 … 230VDC 65m models
Power consumption ≤ 1.5VA Typ. response behaviour
Switching output 3) relay, 1 change-over contact 1,0
Function characteristics break-contact/make-contact 0,8
y2
Switching voltage, relay 250VAC/DC

Misalignment y [m]
0,6
Switching current, relay 250VAC, 3A/30V, 3A 0,4
0,2
Bias current 750VA, cosϕ=1 0
Sensitivity adjustable -0,2
-0,4
Indicators -0,6
LED green ready y1
-0,8
LED yellow light path free -1,0
0 10 20 30 40 50 60 70
LED yellow flashing light path free, no performance reserve Distance x [m]
Mechanical data Metal housing Plastic housing
150m models
Housing diecast zinc polycarbonate
Optics cover glass plastic Typ. response behaviour
Weight 380g 150g 3,5
Connection type terminals terminals 2,5

Misalignment y [m]
y2
Environmental data 1,5

Ambient temp. (operation/storage) -20°C … +60°C/-40°C … +70°C 0,5


Protective circuit 4) 1, 2, 3 0
-0,5
VDE safety class 5) II, all-insulated
-1,5
Protection class IP 67, IP 69K 6) IP 67 y1
LED class 1 (acc. to EN 60825-1) -2,5
Standards applied IEC 60947-5-2 -3,5
0 20 40 60 80 100 120 140 160
Options Distance x [m]
Switching delay (slow oper./release) 0 … 10s (separately adjustable)
y2
1) Typ. operating range limit: max. attainable range without performance reserve y1
2) Operating range: recommended range with performance reserve
3) Suitable spark extinction must be provided with inductive or capacitive loads x
4) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs
5) Rating voltage 250VAC
6) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, Remarks
acids and bases are not part of the test
! LS 96K/R-131P-2
P= Reduction M16

Order guide
Part No. 500 25257 (Re)

Part No. 500 25256 (Re)

Part No. 500 80080 (Re)

Part No. 500 31651 (Re)

Part No. 500 30406 (Re)

Selection table
Part No. 500 25253 (Tr)

Part No. 500 25253 (Tr)

Part No. 500 80081 (Tr)

Part No. 500 80081 (Tr)

Part No. 500 30405 (Tr)

LS = Pair consisting of
LSS = Transmitter
LSE = Receiver
LS 96M/R-1310-2

LS 96M/R-3310-2

LS 96K/R-131P-2
LS 96K/R-1310-2

LS 96K/R-1320-2

Order code " LS 96K/R-1310-2


LSS 96K-1350-26
LSE 96K/R-1310-25
Equipment # LS 96K/R-1320-2
Housing metal ! ! LSS 96K-1350-26
plastic ! ! ! LSE 96K/R-1320-25
Light source infrared light (50m) ! ! ! ! LS 96M/R-1310-2
infrared light (120m) ! LSS 96M-1350-26
LSE 96M/R-1310-25
Connection terminals ! ! ! ! !
Features switching delay ! LS 96M/R-3310-2
LSS 96M-1350-26
UL homologation ! ! ! ! LSE 96M/R-3310-25
LS 96K/R-131P-2
LSS 96K-135P-26
LSE 96K/R-131P-25

LS 96 K/R… - 09 0603
LS 96 M/R… - 09

– 19 –
Leuze electronic
LS 96 Throughbeam photoelectric sensors
Dimensioned drawing

39m

20-230 V
AC / DC
A2 LS

! Throughbeam photoelectric sensors with


high performance reserve in red light
! Wide angle version for easy alignment
! Robust metal housing with glass cover, pro-
tection class IP 67/IP 69K for industrial
application
! All-mains design 20 … 230VAC/DC with
relay output
A Indicator diode green
! Relay with change-over contact, sensitivity B Indicator diode yellow
adjustment and delay before start-up for C Optical axis
optimal adaptation to the application D Screwed cable gland M16x1.5 for Ø 5 … 10mm
! Connection via comfortable terminal com- E Countersinking for SK nut M5, 4.2 deep
partment up to 1.5mm2 F Connection terminals
G Cable entry
H Sensitivity adjustment

Electrical connection (example)


ISO C UL US
9001 LISTED
We reserve the right to make changes • 96_a06e.fm

Transmitter

IP 69K
IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
Receiver
! Mounting systems
(BT 96, BT 96.1, BT 96.4, UMS 96,
BT 450.1-96)
! Spark extinction
! Alignment aid ARH 96

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 LS 96 M/R-176W-2 - 05
www.leuze.de

– 20 –
Leuze electronic
LS 96
Specifications Tables
0 30 39
Optical data
Typ. operating range limit 1) 0 … 39m
Operating range [m]
Operating range 2) 0 … 30m
Light source LED (modulated light) Typ. operating range limit [m]
Wavelength 660nm (red light)
Timing
Switching frequency 20Hz
Response time 25ms
Delay before start-up ≤ 200ms
Electrical data
Operating voltage UB 20 … 230VAC, 50/60Hz
20 … 230VDC
Power consumption ≤ 1.5VA
Switching output 3) relay, 1 change-over contact
Function characteristics break-contact/make-contact
Switching voltage, relay 250VAC/DC
Switching current, relay 250VAC, 3A/30V, 3A
Bias current 750VA, cosϕ=1
Sensitivity adjustable
Indicators
LED green ready
LED yellow light path free
LED yellow flashing light path free, no performance reserve
Mechanical data Metal housing
Housing diecast zinc
Optics cover glass Diagrams
Weight 380g Typ. response behaviour
Connection type terminals 1250
transmitter cable 3x0.5mm2 (oil flex 110), 1.5m 1000
receiver cable 3x0.5mm2 (oil flex 110), 1.5m y2

Misalignment y [mm]
750
500
Environmental data 250
Ambient temp. (operation/storage) -20°C … +60°C/-40°C … +70°C 0
Protective circuit 4) 1, 2, 3 -250
VDE safety class 5) II, all-insulated -500
Protection class IP 67, IP 69K 6) -750
y1
LED class 1 (acc. to EN 60825-1) -1000
-1250
Standards applied IEC 60947-5-2 0 10 20 30 40
Distance x [m]
1) Typ. operating range limit: max. attainable range without performance reserve
2) Operating range: recommended range with performance reserve
y2
3) Suitable spark extinction must be provided with inductive or capacitive loads
y1
4) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs
5) Rating voltage 250VAC x
6) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,
acids and bases are not part of the test

Order guide Remarks


! Angle at a distance of 3m:
Part No. 500 32003 (Re)

Selection table
Part No. 500 32004 (Tr)

transmitter:
LS 96M/R-176W-2

angle of radiation typ. 10°


receiver:
Order code "
receiving angle typ. 12°
! Cable version
wire assignment:
Equipment #
1,2 = supply
Housing metal ! 3,4 = break-contact
Light source red light (30m) !
Connection terminals !
cable tail 1.5m LS = Pair consisting of
LSS = Transmitter
LSE = Receiver

LS 96M/R-176W-2
LSS 96M-175W-26
LSE 96M/R-176W-25

LS 96 M/R-176W-2 - 05 0603

– 21 –
Leuze electronic
SLS 96 Protective throughbeam photoelectric sensors
Dimensioned drawing

65m
39m

10 - 30 V
DC
BG geprüft

! Protective throughbeam photoelectric


sensor cat. 2 (testing) with high perform-
ance reserve in visible red light or infrared
light
! Robust metal housing with glass cover or
plastic housing, protection class IP 67 for
industrial application
! 2 indicators each at the transmitter and A Indicator diode green
receiver for displaying their status when B Indicator diode yellow
commissioning and in operation C Transmitter/receiver
! Optics heating for use with low D Optical axis
temperatures E Device plug M12x1
! Connection via M12 connector or terminal F Screwed cable gland M16x1.5 for Ø 5 … 10mm
compartment G Countersinking for SK nut M5, 4.2 deep
H Connection terminals
I Cable entry

Electrical connection
ISO C UL US
9001 LISTED Transmitter Receiver
We reserve the right to make changes • 96_a07e.fm

IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! M12 connectors (KD …)
! Ready-made cables (K-D …)
! Alignment aid ARH 96
! Test-monitoring units:
- available only from Leuze lumiflex

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 SLS 96 M/P… - 07
www.leuze.de

– 22 –
Leuze electronic
SLS 96
Specifications Tables
Optical data Infrared light Red light
Typ. operating range limit 1) 0 … 65m 0 … 39m
Operating range 2) 0 … 50m 0 … 30m
Light source LED (modulated light) LED (modulated light)
Wavelength 880nm 660nm
Timing
Sensor switching frequency 500Hz
Sensor response time 1ms
Delay before start-up ≤ 200ms
Electrical data
Operating voltage UB 10 … 30VDC (incl. residual ripple)
Residual ripple ≤ 15% of UB
Bias current ≤ 50mA
Switching output PNP transistor
Function characteristics light switching
Signal voltage high/low ≥ (UB -2V)/≤ 2V
Output current max. 100mA
Indicators
LED green ready
Receiver
LED yellow light path free Remarks
LED yellow flashing light path free, no performance reserve ! The protective through-
Transmitter
LED yellow transmitter active beam photoelectric sensor
is a contactless active pro-
Mechanical data Metal housing
Housing diecast zinc tective device only in
Optics cover glass connection with a safety-
Weight 380g relevant control system, in
Connection type terminals or M12 connector which the cyclical testing
Environmental data of transmitter and receiver
Ambient temp. (operation/storage) -20°C … +60°C/-40°C … +70°C is carried out according to
Protective circuit 3) 1, 2, 3 EN 61496-1, category 2
VDE safety class 4) II, all-insulated
Protection class IP 67 (testing).
LED class 1 (acc. to EN 60825-1) ! The power supply unit
Standards applied IEC 60947-5-2
used to operate the photo-
Options electric sensor has to be
Optics heating for temperature changes, prevents fogging
Low temperature to -35°C able to compensate for
Activation input activ changes and interruptions
Transmitter active/not active ≥ 8V/≤ 2V of the supply voltage acc.
Activation/disable delay ≤ 1ms to EN 61496-1.
Input resistance 10KΩ ± 10%
Minimum blackening
1) Typ. operating range limit: max. attainable range without performance reserve object dia: Ø 28mm.
2) Operating range: recommended range with performance reserve
3) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs
4) Rating voltage 250VAC
SLS = Pair consisting of
SLSS = Transmitter
SLSE = Receiver

SLS 96M/P-1070-T2-2
Order guide SLSS 96M-1080-T2-24
SLSE 96M/P-1070-T2-21
Part No. 500 25192 (Re)

Part No. 500 25193 (Re)

Part No. 500 29455 (Re)

Part No. 500 80479 (Re)

Part No. 500 31562 (Re)

Part No. 500 31250 (Re)

Selection table
Part No. 500 25213 (Tr)

Part No. 500 25215 (Tr)

Part No. 500 29454 (Tr)

Part No. 500 80478 (Tr)

Part No. 500 25209 (Tr)

Part No. 500 31249 (Tr)


SLS 96M/P-1070-T2-2

SLS 96M/P-1070-T2-4

SLS 96M/P-1071-T2-2

SLS 96M/P-1071-T2-4

SLS 96M/P-1200-T2-2

SLS 96M/P-1200-T2-4

SLS 96M/P-1070-T2-4
SLSS 96M-1080-T2-45
Order code " SLSE 96M/P-1070-T2-41
SLS 96M/P-1071-T2-2
SLSS 96M-1090-T2-24
Equipment # SLSE 96M/P-1071-T2-21
Housing metal ! ! ! ! ! ! SLS 96M/P-1071-T2-4
plastic SLSS 96M-1090-T2-45
SLSE 96M/P-1071-T2-41
Light source red light (30m) ! !
SLS 96M/P-1200-T2-2
infrared light (50m) ! ! ! !
SLSS 96M-1210-T2-24
Connection terminals ! ! ! SLSE 96M/P-1200-T2-21
M12 connector ! ! ! SLS 96M/P-1200-T2-4
Features optics heating/low temperature ! ! SLSS 96M-1210-T2-45
activation input ! ! ! ! ! ! SLSE 96M/P-1200-T2-41
filter for multi-axis operation

SLS 96 M/P… - 07 0603

– 23 –
Leuze electronic
SLS 96 Protective throughbeam photoelectric sensors
Dimensioned drawing

65m
39m

10 - 30 V
DC
BG geprüft

! Protective throughbeam photoelectric


sensor cat. 2 (testing) with high perform-
ance reserve in visible red light or infrared
light
! Robust metal housing with glass cover or
plastic housing, protection class IP 67 for
industrial application
! 2 indicators each at the transmitter and A Indicator diode green
receiver for displaying their status when B Indicator diode yellow
commissioning and in operation C Transmitter/receiver
! Optics heating for use with low D Optical axis
temperatures E Device plug M12x1
! Connection via M12 connector or terminal F Screwed cable gland M16x1.5 for Ø 5 … 10mm
compartment G Countersinking for SK nut M5, 4.2 deep
H Connection terminals
I Cable entry

Electrical connection
ISO C UL US
9001 LISTED Transmitter Receiver
We reserve the right to make changes • 96_a12e.fm

IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! M12 connectors (KD …)
! Ready-made cables (K-D …)
! Alignment aid ARH 96
! Test-monitoring units:
- available only from Leuze lumiflex

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 SLS 96 K/P… - 07
www.leuze.de

– 24 –
Leuze electronic
SLS 96
Specifications Tables
Optical data Infrared light Red light
Typ. operating range limit 1) 0 … 65m 0 … 39m
Operating range 2) 0 … 50m 0 … 30m
Light source LED (modulated light) LED (modulated light)
Wavelength 880nm 660nm
Timing
Sensor switching frequency 500Hz
Sensor response time 1ms
Delay before start-up ≤ 200ms
Electrical data
Operating voltage UB 10 … 30VDC (incl. residual ripple)
Residual ripple ≤ 15% of UB
Bias current ≤ 50mA
Switching output PNP transistor
Function characteristics light switching
Signal voltage high/low ≥ (UB -2V)/≤ 2V
Output current max. 100mA
Indicators
LED green ready
Receiver
LED yellow light path free Remarks
LED yellow flashing light path free, no performance reserve ! The protective through-
Transmitter
LED yellow transmitter active beam photoelectric sensor
is a contactless active pro-
Mechanical data Plastic housing
Housing polycarbonate tective device only in
Optics cover plastic connection with a safety-
Weight 150g relevant control system, in
Connection type terminals or M12 connector which the cyclical testing
Environmental data of transmitter and receiver
Ambient temp. (operation/storage) -20°C … +60°C/-40°C … +70°C is carried out according to
Protective circuit 3) 1, 2, 3 EN 61496-1, category 2
VDE safety class 4) II, all-insulated
Protection class IP 67 (testing).
LED class 1 (acc. to EN 60825-1) ! The power supply unit
Standards applied IEC 60947-5-2
used to operate the photo-
Options electric sensor has to be
Optics heating for temperature changes, prevents fogging
Low temperature to -35°C able to compensate for
Activation input activ changes and interruptions
Transmitter active/not active ≥ 8V/≤ 2V of the supply voltage acc.
Activation/disable delay ≤ 1ms to EN 61496-1.
Input resistance 10KΩ ± 10%
Minimum blackening
1) Typ. operating range limit: max. attainable range without performance reserve object dia: Ø 28mm.
2) Operating range: recommended range with performance reserve
3) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs
4) Rating voltage 250VAC

SLS = Pair consisting of


SLSS = Transmitter
SLSE = Receiver
Order guide
SLS 96K/P-1070-T2-2
Part No. 500 81293 (Re)

Part No. 500 31561 (Re)

Part No. 500 28010 (Re)

Part No. 500 28012 (Re)

Part No. 500 35078 (Re)

Part No. 500 41109 (Re)

Selection table
Part No. 500 81292 (Tr)

Part No. 500 31559 (Tr)

Part No. 500 28009 (Tr)

Part No. 500 28011 (Tr)

Part No. 500 28009 (Tr)

Part No. 500 28011 (Tr)

SLSS 96K-1080-T2-24
SLS 96K/P-1070-T2-2

SLS 96K/P-1070-T2-4

SLS 96K/P-1200-T2-2

SLS 96K/P-1200-T2-4

SLS 96K/P-1207-T2-2

SLS 96K/P-1207-T2-4

SLSE 96K/P-1070-T2-21
SLS 96K/P-1070-T2-4
Order code " SLSS 96K-1080-T2-45
SLSE 96K/P-1070-T2-41
SLS 96K/P-1200-T2-2
Equipment # SLSS 96K-1210-T2-24
Housing metal SLSE 96K/P-1200-T2-21
plastic ! ! ! ! ! ! SLS 96K/P-1200-T2-4
Light source red light (30m) ! ! ! ! SLSS 96K-1210-T2-45
infrared light (50m) ! ! SLSE 96K/P-1200-T2-41
Connection terminals ! ! ! SLS 96K/P-1207-T2-2
M12 connector ! ! ! SLSS 96K-1210-T2-24
SLSE 96K/P-1207-T2-21
Features optics heating/low temp.
SLS 96K/P-1207-T2-4
activation input ! ! ! ! ! !
SLSS 96K-1210-T2-45
filter for multi-axis operation ! ! SLSE 96K/P-1207-T2-41

SLS 96 K/P… - 07 0603

– 25 –
Leuze electronic
LS 96 Throughbeam photoelectric sensors
Dimensioned drawing

39m

! Throughbeam photoelectric sensors with


high performance reserve in red light
! Robust metal housing with glass cover, pro-
tection class IP 67/IP 69K for industrial
application
! Receiver with integrated AS-i slave
technology A Indicator diode green
B Indicator diode yellow
! Transmitter without integrated AS-i slave
C Optical axis
technology; receives voltage supply via
D Device plug M12x1
AS-i line
E Countersinking for SK nut M5, 4.2 deep
! Wide angle version to simplify the alignment

Electrical connection
ISO C UL US
9001 LISTED

IP 69K
IEC 60947... IEC 60947... IP 67
We reserve the right to make changes • 96_a09e.fm

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! M12 connectors
! Ready-made cables (K-D …)
! Alignment aid ARH 96

AS-i Accessories:
(available separately)
! Bus terminals
! AS-i ribbon cable
! Address programming device
! Coupling modules, intermediate cables, etc.

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 LS 96M/A-182W-4 - 06
www.leuze.de

– 26 –
Leuze electronic
LS 96
Specifications Tables
0 30 39
Optical data
Typ. operating range limit 1) 0 … 39m Operating range [m]
Operating range 2) 0 … 30m Typ. operating range limit [m]
Light source LED (modulated light)
Wavelength 660nm (red light)
Timing
Sensor switching frequency 500Hz
Sensor response time 1ms
Delay before start-up ≤ 200ms
Electrical data
Operating voltage UB 26.5 … 31.6V (according to AS-i specification)
Bias current receiver ≤ 35mA
Bias current transmitter ≤ 15mA
Indicators
LED green ready
LED yellow light path free
LED yellow flashing light path free, no performance reserve
Mechanical data Metal housing
Housing diecast zinc
Optics cover glass
Weight 380g
Connection type M12 connector
Environmental data
Ambient temp. (operation/storage) -20°C … +60°C/-40°C … +70°C
Protective circuit 3) 1, 2 Diagrams
VDE safety class 4) II, all-insulated Typ. response behaviour
Protection class IP 67, IP 69K 5) 400
LED class 1 (acc. to EN 60825-1)

Misalignment y [mm]
300
Standards applied IEC 60947-5-2 200
y2
AS-i data for receiver 100
I/O code 1 0
ID code 1 -100
y1
Cycle time acc. to AS-i specification 5ms -200
AS-i standard according to profile S-1.1 -300
-400
1) Typ. operating range limit: max. attainable range without performance reserve 0 5 10 15 20 25 30 35 40 45 50

2) Operating range: recommended range with performance reserve Distance x [m]


3) 1=transient protection, 2=polarity reversal protection
4) Rating voltage 250VAC y2
5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, y1
acids and bases are not part of the test
x

Assignment: data bits Assignment: parameter bits


Programming Programming
(host level) (host level)
Switching out- Ø no reflection System Ø System
D0 *P0 NC
put 1 reflection input 1 parameter
Ø active Ø dark switching
D1 Warning output System *P1 Light/dark System
autoControl 1 not active input switching 1 light switching parameter
Ø sensor not ready System Ø System
D2 Ready output
1 sensor ready input
*P2 NC
1 parameter Remarks
*D3 NC
Ø
*P3 NC
Ø System ! The transmitter has no
1 1 parameter integrated AS-i slave
* default = 1 technology.
! The low current
Order guide consumption of the
transmitter enables power
Designation Part No. supply via AS-i line.
Transmitter and receiver LS 96M/A-182W-4 ! Transmitter and receiver
Transmitter LSS 96 M-180W-44 500 82040 behave like a slave in an
Receiver LSE 96 M/A-182W-44 500 82039 AS-i branch.

Angle at 3m distance:
Transmitter:
Angle of radiation typ.: 10°
Receiver:
Receiving angle typ.: 12°

LS 96M/A-182W-4 - 06 0603

– 27 –
Leuze electronic
RK 96 Retro-reflective photoelectric sensors
Dimensioned drawing

18m

10 - 30 V
DC
A2 LS

! Retro-reflective photoelectric sensors with a


long operating range
! Invisible infrared light
! Robust metal housing with glass cover or
plastic housing, protection class IP 67/
IP 69K for industrial application
! Complementary outputs, sensitivity
adjustment and delay before start-up for
optimal adaptation to the application
! Connection via comfortable terminal com-
partment up to 1.5mm² A Indicator diode green
B Indicator diode yellow
C Optical axis
D Screwed cable gland M16x1.5 for Ø 5 … 10mm
E Countersinking for SK nut M5, 4.2 deep
F Connection terminals
G Cable entry
H Sensitivity adjustment
ISO C UL US
9001 LISTED Electrical connection
We reserve the right to make changes • 96_b01e.fm

IP 69K
IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, UMS 96, BT 450.1-96)
! Reflectors
! Reflective tapes

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 RK 96 M/P-1440-21 - 05
www.leuze.de

– 28 –
Leuze electronic
RK 96
Specifications Tables
Optical data Reflectors Operating
range
Typ. operating range limit (TK(S) 100x100) 1) 18m
Operating range 2) see tables 1 TK(S) 100x100 0.3 … 15m
Light source LED (modulated light) 2 MTK(S) 50x50 0.3 … 11m
Wavelength 880nm (infrared)
3 TK(S) 30x50 0.3 … 6m
Timing 4 TK(S) 20x40 0.3 … 5m
Switching frequency 1000Hz 5 TK(S) 82 0.3 … 11m
Response time 0.5ms 6 Tape 2 100x100 0.3 … 6m
Delay before start-up ≤ 200ms
Electrical data 1 0.1 15 18
Operating voltage UB 10 … 30VDC (incl. residual ripple) 2 0.1 11 12
Residual ripple ≤ 15% of UB 3 0.1 6 7.1
Bias current ≤ 40mA 4 0.1 5 6
Switching output PNP transistor 5 0.1 11 12
Function characteristics light/dark switching 6 0.1 6 8
Signal voltage high/low ≥ (UB -2V)/≤ 2V
Output current max. 100mA Operating range [m]
Sensitivity adjustable Typ. operating range limit [m]
Indicators TK … = adhesive
LED green ready TKS … = screw type
LED yellow light path free Tape 2 = adhesive
LED yellow flashing light path free, no performance reserve
Mechanical data Metal housing
Housing diecast zinc
Optics cover glass
Weight 380g Diagrams
Connection type terminals Typ. response behaviour (TKS 100x100)
Environmental data 250
200

Misalignment y [mm]
Ambient temp. (operation/storage) -20°C … +55°C/-40°C … +55°C 150
y2
Protective circuit 3) 1, 2, 3, 4 100
VDE safety class 4) II, all-insulated 50
Protection class IP 67, IP 69K 5) 0
-50
LED class 1 (acc. to EN 60825-1) -100
Standards applied IEC 60947-5-2 -150 y1
-200
1) Typ. operating range limit: max. attainable range without performance reserve -250
0 5 10 15 20
2) Operating range: recommended range with performance reserve Distance x [m]
3) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, 4=interference blanking
4) Rating voltage 250VAC
5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, y2
acids and bases are not part of the test y1

Order guide Remarks


Designation Part No.
Metal housing RK 96M/P-1440-21 500 30648

RK 96 M/P-1440-21 - 05 0603

– 29 –
Leuze electronic
RK 96 Retro-reflective photoelectric sensors
Dimensioned drawing

18m

20-230 V
AC / DC
A2 LS

! Retro-reflective photoelectric sensor with a


large operating range
! Robust plastic housing, protection class
IP 67 for industrial application
! All-mains design 20 … 230VAC/DC with
relay output
! Relay with change-over contact, sensitivity
adjustment and delay before start-up for
optimal adaptation to the application
! Connection via comfortable terminal com-
partment up to 1.5mm² A Indicator diode green
B Indicator diode yellow
C Optical axis
D Screwed cable gland M16x1.5 for Ø 5 … 10mm
E Countersinking for SK nut M5, 4.2 deep
F Connection terminals
G Cable entry
H Sensitivity adjustment
ISO C UL US
9001 LISTED Electrical connection
We reserve the right to make changes • 96_b02e.fm

IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, UMS 96, BT 450.1-96)
! Spark extinction
! Reflectors
! Reflective tapes

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 RK 96 K/R-1560-25 - 06
www.leuze.de

– 30 –
Leuze electronic
RK 96
Specifications Tables
Optical data Reflectors Operating
range
Typ. operating range limit (TK(S) 100x100) 1) 18m
Operating range 2) see tables 1 TK(S) 100x100 0.3 … 15m
Light source LED (modulated light) 2 MTK(S) 50x50 0.3 … 11m
Wavelength 880nm (infrared)
3 TK(S) 30x50 0.3 … 6m
Timing 4 TK(S) 20x40 0.3 … 5m
Switching frequency 20Hz 5 TK(S) 82 0.3 … 11m
Response time 25ms 6 Tape 2 100x100 0.3 … 6m
Delay before start-up ≤ 200ms
Electrical data 1 0.1 15 18
Operating voltage UB 20 … 230VAC, 50/60Hz 2 0.1 11 12
20 … 230VDC 3 0.1 6 7.1
Power consumption ≤ 1.5VA 4 0.1 5 6
Switching output 3) relay, 1 change-over contact 5 0.1 11 12
Function characteristics break-contact/make-contact 6 0.1 6 8
Switching voltage, relay 250VAC/DC
Switching current, relay 250VAC, 3A/30VDC, 3A Operating range [m]
Switching power, relay 750VA, cosϕ=1 Typ. operating range limit [m]
Sensitivity adjustable
TK … = adhesive
Indicators TKS … = screw type
LED green ready Tape 2 = adhesive
LED yellow light path free
LED yellow flashing light path free, no performance reserve
Mechanical data Plastic housing
Housing polycarbonate
Optics cover plastic
Weight 150g
Connection type terminals Diagrams
Typ. response behaviour (TKS 100x100)
Environmental data 250
Ambient temp. (operation/storage) -20°C … +55°C/-40°C … +55°C 200

Misalignment y [mm]
y2
Protective circuit 4) 1, 4 150
VDE safety class 5) II, all-insulated 100
50
Protection class IP 67 0
LED class 1 (acc. to EN 60825-1) -50
Standards applied IEC 60947-5-2 -100
-150 y1
1) Typ. operating range limit: max. attainable range without performance reserve -200
-250
2) Operating range: recommended range with performance reserve 0 5 10 15 20
3) Suitable spark extinction must be provided with inductive or capacitive loads Distance x [m]
4) 1=transient protection, 4=interference blanking
5) Rating voltage 250VAC
y2
y1

Order guide Remarks


Designation Part No. ! PRK 96 K/R-156P-25
P = Reduction M16
RK 96K/R-1560-25 500 80484
RK 96K/R-156P-25 500 30404

RK 96 K/R-1560-25 - 06 0603

– 31 –
Leuze electronic
PRK 96 Retro-reflective photoelectric sensors with polarisation filter
Dimensioned drawing

10m
18m

10 - 30 V
DC
A2 LS

! Polarised retro-reflective photoelectric


sensor with large operating range in visible
red light
! Robust metal housing with glass cover or
plastic housing, protection class IP 67/
A Indicator diode green
IP 69K for industrial application
B Indicator diode yellow
! Complementary outputs, sensitivity C Receiver
adjustment and delay before start-up for D Transmitter
optimal adaptation to the application E Optical axis
! Connection via M12 connector or terminal F Device plug M12x1
compartment G Screwed cable gland M16x1.5 for Ø 5 … 10mm
H Countersinking for SK nut M5, 4.2 deep
! Multiple options with warning output, activa-
I Connection terminals
tion input, switching delays and optics
K Cable entry
heating for use at low temperatures
L Sensitivity adjustment

Electrical connection
ISO C UL US
9001 LISTED
We reserve the right to make changes • 96_b03e.fm

IP 69K
IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! M12 connectors (KD …)
! Ready-made cables (K-D …)
! Reflectors
! Reflective tapes

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 PRK 96 M/P… - 08
www.leuze.de

– 32 –
Leuze electronic
PRK 96
Specifications Tables
10m models
Optical data Reflectors Operating
Typ. operating range limit (TK(S) 100x100) 1) 10m/18m range
Operating range 2) see tables
Light spot diameter approx. 130mm at 6m 1 TK(S) 100x100 0.3 … 8m
Light source LED (modulated light) 2 MTK(S) 50x50 0.3 … 7m
Wavelength 660nm (visible red light, polarised) 3 TK(S) 30x50 0.3 … 4.5m
Timing 4 TK(S) 20x40 0.3 … 3m
Switching frequency 1000Hz 5 TK(S) 82 0.3 … 6m
Response time 0.5ms 6 Tape 2 100x100 0.3 … 4m
Delay before start-up ≤ 200ms
1 0.1 8 10
Electrical data 2 0.1 7 8.5
Operating voltage UB 10 … 30VDC (incl. residual ripple) 3 0.1 4.5 5
Residual ripple ≤ 15% of UB 4 0.1 3 4
Bias current ≤ 40mA, ≤ 75mA with optics heating 5 0.1 6 7.5
Switching output PNP or NPN transistor 6 0.1 4 5.5
Function characteristics light/dark switching
Signal voltage high/low ≥ (UB -2V)/≤ 2V 18m models
Output current max. 100mA Reflectors Operating
Sensitivity adjustable range
Indicators 1 TK(S) 100x100 0.3 … 15m
LED green ready 2 MTK(S) 50x50 0.3 … 11m
LED yellow light path free 3 TK(S) 30x50 0.3 … 6m
LED yellow flashing light path free, no performance reserve 4 TK(S) 20x40 0.3 … 5m
Mechanical data Metal housing 5 TK(S) 82 0.3 … 11m
Housing diecast zinc 6 Tape 2 100x100 0.3 … 6m
Optics cover glass
1 0.1 15 18
Weight 380g
Connection type terminals or M12 connector 2 0.1 11 12
3 0.1 6 7.5
Environmental data 4 0.1 5 6
Ambient temp. (operation/storage) -20°C … +55°C/-40°C … +55°C 5 0.1 11 11.5
Protective circuit 3) 1, 2, 3, 4 6 0.1 6 7.5
VDE safety class 4) II, all-insulated
Protection class IP 67, IP 69K 5) Operating range [m]
LED class 1 (acc. to EN 60825-1) Typ. operating range limit [m]
Standards applied IEC 60947-5-2
Options Diagrams
Warning output autoControl warn PNP transistor, 100mA, counting principle 10m models
Optics heating for temperature changes, prevents fogging Typ. response behaviour (TKS 100x100)
Low temperature to -35°C 150
y2
Misalignment y [mm]
Switching delay (slow oper./release) 0 … 10s (separately adjustable) 100

1) Typ. operating range limit: max. attainable range without performance reserve 50

2) Operating range: recommended range with performance reserve 0


3) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, 4=interference blanking -50
4) Rating voltage 250VAC
-100
5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, y1
acids and bases are not part of the test -150
0 2 4 6 8 10 12
Distance x [m]
18m models
Typ. response behaviour (TKS 100x100)
150
Misalignment y [mm]

Order guide 100


y2
50
PRK 96M/P-1361.1-47

Selection table 0
PRK 96M/N-3366-27
PRK 96M/P-1370-22

PRK 96M/P-1370-42

PRK 96M/P-1400-22

PRK 96M/P-1400-42

PRK 96M/P-3360-21

PRK 96M/P-3380-41
Part No. 500 25182

Part No. 500 25186

Part No. 500 25178

Part No. 500 31549

Part No. 500 82065

Part No. 501 02379

Part No. 500 61452

Part No. 501 04279

-50
y1
-100
Order code "
-150
0 5 10 15 20
Distance x [m]

Equipment #
y2
y1
Housing metal ! ! ! ! ! ! ! !
x
plastic
Light source red light (8m) ! ! ! ! ! Remarks
red light (15m) ! ! ! ! The polarised retro-reflective
photoelectric sensor is also
Connection terminals ! ! ! ! available with an integrated
M12 connector ! ! ! ! AS-i chip for direct connection
to the AS-i system.
Features optics heating/low temp. ! ! !
switching delay ! ! !
warning output ! ! ! !
activation input !
NPN switching output !
Light/dark switching !

PRK 96 M/P… - 08 0603

– 33 –
Leuze electronic
PRK 96 Retro-reflective photoelectric sensors with polarisation filter
Dimensioned drawing

10m
28m

10 - 30 V
DC
A2 LS

! Polarised retro-reflective photoelectric


sensor with large operating range in visible
red light
! Robust metal housing with glass cover or
plastic housing, protection class IP 67 for
A Indicator diode green
industrial application
B Indicator diode yellow
! Complementary outputs for standard C Receiver
applications and a wide range of input and D Transmitter
output variants for optimum adaptation to E Optical axis
the application F Device plug M12x1
! Connection via M12 connector or terminal G Screwed cable gland M16x1.5 for Ø 5 … 10mm
compartment H Countersinking for SK nut M5, 4.2 deep
I Connection terminals
! Multiple options with warning output, activa-
K Cable entry
tion input, switching delays and optics
L Sensitivity adjustment
heating for use at low temperatures

Electrical connection
ISO C UL US
9001 LISTED
We reserve the right to make changes • 96_b14e.fm

IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! M12 connectors (KD …)
! Ready-made cables (K-D …)
! Reflectors
! Reflective tapes

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 PRK 96 K/P… - 09
www.leuze.de

– 34 –
Leuze electronic
PRK 96
Specifications Tables
10m models
Optical data Reflectors Operating
Typ. operating range limit (TK(S) 100x100) 1) 10m/28m range
Operating range 2) see tables
Light spot diameter approx. 130mm at 6m 1 TK(S) 100x100 0.3 … 8m
Light source LED (modulated light) 2 MTK(S) 50x50 0.3 … 7m
Wavelength 660nm (visible red light, polarised) 3 TK(S) 30x50 0.3 … 4.5m
Timing 4 TK(S) 20x40 0.3 … 3m
Switching frequency 1000Hz/20Hz 5 TK(S) 82 0.3 … 6m
Response time 0.5ms/25ms 6 Tape 2 100x100 0.3 … 4m
Delay before start-up ≤ 200ms
1 0.1 8 10
Electrical data 2 0.1 7 8.5
Operating voltage UB 10 … 30VDC (incl. residual ripple) 3 0.1 4.5 5
Residual ripple ≤ 15% of UB 4 0.1 3 4
Bias current ≤ 40mA, ≤ 75mA with optics heating 5 0.1 6 7.5
Switching output PNP transistor 6 0.1 4 5.5
Function characteristics light/dark switching (reversible)
Signal voltage high/low ≥ (UB -2V)/≤ 2V 28m models
Output current max. 100mA Reflectors Operating
Sensitivity adjustable range
Indicators 1 TK(S) 100x100 0.3 … 28m
LED green ready
LED yellow light path free 1 0.1 26 28
LED yellow flashing light path free, no performance reserve
Operating range [m]
Mechanical data Plastic housing Typ. operating range limit [m]
Housing polycarbonate
Optics cover plastic
Weight 150g Diagrams
Connection type terminals or M12 connector 10m models
Environmental data Typ. response behaviour (TKS 100x100)
Ambient temp. (operation/storage) -20°C … +55°C/-40°C … +55°C 150
Protective circuit 3) 1, 2, 3, 4 y2

Misalignment y [mm]
100
VDE safety class 4) II, all-insulated
50
Protection class IP 67
LED class 1 (acc. to EN 60825-1) 0
Standards applied IEC 60947-5-2 -50

Options -100
y1
Warning output autoControl warn PNP transistor, 100mA, counting principle -150
0 2 4 6 8 10 12
Optics heating for temperature changes, prevents fogging Distance x [m]
Low temperature to -35°C
Switching delay (slow oper./release) 0 … 10s (separately adjustable) 28m models
Typ. response behaviour (TKS 100x100)
1) Typ. operating range limit: max. attainable range without performance reserve
2) Operating range: recommended range with performance reserve 200
Misalignment y [mm]

3) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, 4=interference blanking 150
y2
100
4) Rating voltage 250VAC
50
0
-50
-100
y1
-150
-200
Order guide 0 5 10 15
Distance x [m]
20 25 30
PRK 96K/P-1360.1-41

Selection table
PRK 96K/N-1380-46
PRK 96K/P-1360-21

PRK 96K/P-1360-41

PRK 96K/P-3368-41

PRK 96K/P-1380-21

PRK 96K/P-1380-41

PRK 96K/P-1365-45
Part No. 500 25163

Part No. 500 25165

Part No. 500 41042

Part No. 500 25164

Part No. 500 25166

Part No. 501 03003

Part No. 501 03216

Part No. 500 81325

y2
y1

Order code " x

Remarks
Equipment #
! The polarised retro-reflec-
Housing metal tive photoelectric sensor is
also available with an inte-
plastic ! ! ! ! ! ! ! !
grated AS-i chip for direct
Light red light (10m) ! ! ! ! ! ! ! connection to the AS-i
source red light (28m) ! system.
Connection terminals ! ! ! *For direct connection to
M12 connector ! ! ! ! ! ! AS-i I/O coupling modules
Features switching delay ! ! ! (PRK 96K/P-1365-45 and
warning output PRK 96K/P-1360.1-41)
activation input
PIN 2 = NC * ! !
PIN 4 = dark switching !
PIN 4 = light/dark reversible !
NPN switching output !

PRK 96 K/P… - 09 0603

– 35 –
Leuze electronic
PRK 96 Retro-reflective photoelectric sensors with polarisation filter
Dimensioned drawing

10m

10 - 30 V
DC
A2 LS

! Polarised retro-reflective photoelectric


sensor with large operating range in visible
red light
! Robust metal housing with glass cover or
plastic housing, protection class IP 67/
IP 69K for industrial application
A Indicator diode green
! Sensitivity adjustment and delay before B Indicator diode yellow
start-up for optimal adaptation to the C Receiver
application D Transmitter
! Connection via M12 connector or terminal E Optical axis
compartment F Device plug M12x1
! Activation input for e.g. muting applications G Screwed cable gland M16x1.5 for Ø 5 … 10mm
H Countersinking for SK nut M5, 4.2 deep
I Connection terminals
K Cable entry
L Sensitivity adjustment

Electrical connection
ISO C UL US
9001 LISTED
We reserve the right to make changes • 96_b04e.fm

IP 69K
IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! M12 connectors (KD …)
! Ready-made cables (K-D …)
! Reflectors
! Reflective tapes

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 PRK 96 K/P… - 08
www.leuze.de PRK 96 M/P… - 08

– 36 –
Leuze electronic
PRK 96
Specifications Tables
Optical data Reflectors Operating
range
Typ. operating range limit (TK(S) 100x100) 1) 10m
Operating range 2) see tables 1 TK(S) 100x100 0.3 … 8m
Light spot diameter approx. 130mm at 6m 2 MTK(S) 50x50 0.3 … 7m
Light source LED (modulated light)
3 TK(S) 30x50 0.3 … 4.5m
Wavelength 660nm (visible red light, polarised)
4 TK(S) 20x40 0.3 … 3m
Timing 5 TK(S) 82 0.3 … 6m
Switching frequency 1000Hz 6 Tape 2 100x100 0.3 … 4m
Response time 0.5ms
Delay before start-up ≤ 200ms
1 0.1 8 10
Electrical data 2 0.1 7 8.5
Operating voltage UB 10 … 30VDC (incl. residual ripple) 3 0.1 4.5 5
Residual ripple ≤ 15% of UB 4 0.1 3 4
Bias current ≤ 40mA 5 0.1 6 7.5
Switching output PNP transistor 6 0.1 4 5.5
Function characteristics light switching
Signal voltage high/low ≥ (UB -2V)/≤ 2V Operating range [m]
Output current max. 100mA Typ. operating range limit [m]
Sensitivity adjustable
TK … = adhesive
Indicators TKS … = screw type
LED green ready Tape 2 = adhesive
LED yellow light path free
LED yellow flashing light path free, no performance reserve
Mechanical data Metal housing Plastic housing
Housing diecast zinc polycarbonate
Optics cover glass plastic Diagrams
Weight 380g 150g Typ. response behaviour (TKS 100x100)
Connection type terminals or M12 connector 150
Environmental data y2

Misalignment y [mm]
100
Ambient temp. (operation/storage) -20°C … +55°C/-40°C … +55°C 50
Protective circuit 3) 1, 2, 3, 4
VDE safety class 4) II, all-insulated 0

Protection class IP 67, IP 69K 5) IP 67 -50


LED class 1 (acc. to EN 60825-1) -100
y1
Standards applied IEC 60947-5-2
-150
0 2 4 6 8 10 12
Options Distance x [m]
Activation input activ
Transmitter active/not active ≥ 8V/≤ 2V (≥ 2V/≤ 2V) 6)
Activation/disable delay ≤ 0.5ms y2
Input resistance 47KΩ ± 10% y1

1) Typ. operating range limit: max. attainable range without performance reserve x
2) Operating range: recommended range with performance reserve
3) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, 4=interference blanking
4) Rating voltage 250VAC
5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,
acids and bases are not part of the test
6) Active low

Order guide Remarks


! The polarised retro-reflec-
PRK 96M/P-1361-47

PRK 96M/P-1362-47

Selection table
PRK 96K/P-1361-29

PRK 96K/P-1363-29
Part No. 500 80476

Part No. 500 82092

Part No. 500 80656

Part No. 500 80477

tive photoelectric sensor is


also available with an inte-
Order code " grated AS-i chip for direct
connection to the AS-i
system.
Equipment #
! PRK 96K/P-1363-29
Housing metal ! ! Activation via active low
plastic ! ! signal
Light source red light (8m) ! ! ! !
Connection terminals ! !
M12 connector ! !
Features activation input ! ! ! 6) !
optics heating/low temperature !

PRK 96 K/P… - 08 0603


PRK 96 M/P… - 08

– 37 –
Leuze electronic
PRK 96 Retro-reflective photoelectric sensors with polarisation filter
Dimensioned drawing

10m
18m

20-230 V
AC / DC
A2 LS

! Polarised retro-reflective photoelectric


sensor with large operating range in visible
red light
! Robust metal housing with glass cover or
plastic housing, protection class IP 67/
IP 69K for industrial application A Indicator diode green
! All-mains design 20 … 230VAC/DC with B Indicator diode yellow
relay output C Receiver
D Transmitter
! Relay with change-over contact, sensitivity
E Optical axis
adjustment, delay before start-up and vari-
F Screwed cable gland M16x1.5 for Ø 5 … 10mm
ous options for optimal adaptation to the
G Countersinking for SK nut M5, 4.2 deep
application
H Connection terminals
! Connection via comfortable terminal com- I Cable entry
partment up to 1.5mm² K Sensitivity adjustment

Electrical connection
ISO
9001
We reserve the right to make changes • 96_b05e.fm

IP 69K
IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! Spark extinction
! Reflectors
! Reflective tapes

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 PRK 96 M/R… - 08
www.leuze.de

– 38 –
Leuze electronic
PRK 96
Specifications Tables
Optical data 10m models
Typ. operating range limit (TK(S) 100x100) 1) 10m/18m Reflectors Operating
Operating range 2) see tables range
Light spot diameter approx. 130mm at 6m
Light source LED (modulated light) 1 TK(S) 100x100 0.3 … 8m
Wavelength 660nm (visible red light, polarised) 2 MTK(S) 50x50 0.3 … 7m
3 TK(S) 30x50 0.3 … 4.5m
Timing 4 TK(S) 20x40 0.3 … 3m
Switching frequency 20Hz
Response time 25ms 5 TK(S) 82 0.3 … 6m
Delay before start-up ≤ 200ms 6 Tape 2 100x100 0.3 … 4m
1 0.1 8 10
Electrical data
Operating voltage UB 20 … 230VAC, 50/60Hz 2 0.1 7 8.5
20 … 230VDC ± 10% 3 0.1 4.5 5
Power consumption ≤ 1.5VA 4 0.1 3 4
Switching output 3) relay, 1 change-over contact 5 0.1 6 7.5
Function characteristics break-contact/make-contact 6 0.1 4 5.5
Switching voltage, relay 250VAC/DC 18m models
Switching current, relay 250VAC, 3A/30VDC, 3A
Switching power, relay 750VA, cosϕ=1 Reflectors Operating
Sensitivity adjustable range

Indicators 1 TK(S) 100x100 0.3 … 15m


LED green ready 2 MTK(S) 50x50 0.3 … 11m
LED yellow light path free 3 TK(S) 30x50 0.3 … 6m
LED yellow flashing light path free, no performance reserve 4 TK(S) 20x40 0.3 … 5m
Mechanical data Metal housing 5 TK(S) 82 0.3 … 11m
Housing diecast zinc 6 Tape 2 100x100 0.3 … 6m
Optics cover glass 1 0.1 15 18
Weight 380g 2 0.1 11 12
Connection type terminals 3 0.1 6 7.5
Environmental data 4 0.1 5 6
Ambient temp. (operation/storage) -20°C … +55°C/-40°C … +55°C 5 0.1 11 11.5
Protective circuit 4) 1, 4 6 0.1 6 7.5
VDE safety class 5) II, all-insulated
Protection class IP 67, IP 69K 6) Operating range [m]
LED class 1 (acc. to EN 60825-1) Typ. operating range limit [m]
Standards applied IEC 60947-5-2
Options
Switching delay (slow oper./release) 0 … 10s (separately adjustable)
Diagrams
1) Typ. operating range limit: max. attainable range without performance reserve
10m models
2) Operating range: recommended range with performance reserve
Typ. response behaviour (TKS 100x100)
3) Suitable spark extinction must be provided with inductive or capacitive loads
150
4) 1=transient protection, 4=interference blanking y2
Misalignment y [mm]

5) Rating voltage 250VAC 100


6) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, 50
acids and bases are not part of the test 0

-50

-100
y1
-150
0 2 4 6 8 10 12
Distance x [m]

18m models
Order guide Typ. response behaviour (TKS 100x100)
150
Selection table
PRK 96M/R-3420-25

PRK 96M/R-3430-25

Misalignment y [mm]
Part No. 500 82066

Part No. 500 61111

100
y2
50
Order code " 0

-50
Equipment # -100
y1

-150
0 5 10 15 20
Housing metal ! ! Distance x [m]

plastic
y2
Light source red light (8m) y1

red light (15m) ! ! x


red light (20m)
Connection terminals ! !
M12 connector Remarks
Features optics heating/low temperature
switching delay !

PRK 96 M/R… - 08 0603

– 39 –
Leuze electronic
PRK 96 Retro-reflective photoelectric sensors with polarisation filter
Dimensioned drawing

10m
24m

20-230 V
AC / DC
A2 LS

! Polarised retro-reflective photoelectric


sensor with large operating range in visible
red light
! Robust metal housing with glass cover or
plastic housing, protection class IP 67 for
industrial application A Indicator diode green
! All-mains design 20 … 230VAC/DC with B Indicator diode yellow
relay output C Receiver
D Transmitter
! Relay with change-over contact, sensitivity
E Optical axis
adjustment, delay before start-up and vari-
F Screwed cable gland M16x1.5 for Ø 5 … 10mm
ous options for optimal adaptation to the
G Countersinking for SK nut M5, 4.2 deep
application
H Connection terminals
! Connection via comfortable terminal com- I Cable entry
partment up to 1.5mm² K Sensitivity adjustment

Electrical connection
ISO C UL US
9001 LISTED
We reserve the right to make changes • 96_b15e.fm

IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! Spark extinction
! Reflectors
! Reflective tapes

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 PRK 96 K/R… - 08
www.leuze.de

– 40 –
Leuze electronic
PRK 96
Specifications Tables
10m models
Optical data Reflectors Operating
Typ. operating range limit (TK(S) 100x100) 1) 10m/24m range
Operating range 2) see tables
Light spot diameter approx. 130mm at 6m 1 TK(S) 100x100 0.3 … 8m
Light source LED (modulated light) 2 MTK(S) 50x50 0.3 … 7m
Wavelength 660nm (visible red light, polarised) 3 TK(S) 30x50 0.3 … 4.5m
Timing 4 TK(S) 20x40 0.3 … 3m
Switching frequency 20Hz 5 TK(S) 82 0.3 … 6m
Response time 25ms 6 Tape 2 100x100 0.3 … 4m
Delay before start-up ≤ 200ms
1 0.1 8 10
Electrical data 2 0.1 7 8.5
Operating voltage UB 20 … 230VAC, 50/60Hz 3 0.1 4.5 5
20 … 230VDC ± 10% 4 0.1 3 4
Power consumption ≤ 1.5VA 5 0.1 6 7.5
Switching output 3) relay, 1 change-over contact 6 0.1 4 5.5
Function characteristics break-contact/make-contact
Switching voltage, relay 250VAC/DC 24m models
Switching current, relay 250VAC, 3A/30VDC, 3A Reflectors Operating
Switching power, relay 750VA, cosϕ=1 range
Sensitivity adjustable
1 TK(S) 100x100 0.3 … 20m
Indicators 2 MTK(S) 50x50 0.3 … 15m
LED green ready
LED yellow light path free 3 TK(S) 30x50 0.3 … 10m
LED yellow flashing light path free, no performance reserve 4 TK(S) 20x40 0.3 … 8m
5 TK(S) 82 0.3 … 15m
Mechanical data Plastic housing 6 Tape 2 100x100 0.3 … 10m
Housing polycarbonate
Optics cover plastic 1 0.1 20 24
Weight 150g 2 0.1 15 16
Connection type terminals 3 0.1 10 12
4 0.1 8 9
Environmental data
5 0.1 15 17
Ambient temp. (operation/storage) -20°C … +55°C/-40°C … +55°C
6 0.1 10 12
Protective circuit 4) 1, 4
VDE safety class 5) II, all-insulated
Protection class IP 67 Operating range [m]
LED class 1 (acc. to EN 60825-1) Typ. operating range limit [m]
Standards applied IEC 60947-5-2
Options
Switching delay (slow oper./release) 0 … 10s (separately adjustable)
Diagrams
1) Typ. operating range limit: max. attainable range without performance reserve
10m models
2) Operating range: recommended range with performance reserve
Typ. response behaviour (TKS 100x100)
3) Suitable spark extinction must be provided with inductive or capacitive loads
150
4) 1=transient protection, 4=interference blanking y2
Misalignment y [mm]

5) Rating voltage 250VAC 100

50

-50

-100
y1
-150
0 2 4 6 8 10 12
Distance x [m]

24m models
Order guide Typ. response behaviour (TKS 100x100)
200
PRK 96K/R-1420-25

PRK 96K/R-1430-25

PRK 96K/R-3428-25

Selection table
Part No. 500 25167

Part No. 500 25168

Part No. 500 35351

Misalignment y [mm]

150
y2
100

Order code " 50


0
-50

Equipment # -100
-150
y1

-200
0 5 10 15 20 25 30
Housing metal Distance x [m]

plastic ! ! !
y2
Light source red light (8m) ! ! y1
red light (15m) x
red light (20m) !
Connection terminals ! ! !
M12 connector
Remarks
Features optics heating/low temp.
switching delay !
UL homologation ! !

PRK 96 K/R… - 08 0603

– 41 –
Leuze electronic
PRK 96 Retro-reflective photoelectric sensors with polarisation filter
Dimensioned drawing

0 … 1.85m

10 - 30 V
DC

! Retro-reflective photoelectric sensor for


safe detection of transparent media
(e.g. clear glass, PE, foil)
! Reliable detection of the smallest gaps
between transparent objects
! User controlled sensitivity adjustment with
high resolution
! The autocollimation principle used ensures A Indicator diode green
that the device functions reliably over the B Indicator diode yellow
entire range (0 … max.) C Optical axis
! High switching frequency for detection of D Device plug M12x1
fast events E Screwed cable gland M16x1.5 for Ø 5 … 10mm
F Countersinking for SK nut M5, 4.2 deep
! Connection via M12 connector or terminal
G Connection terminals
compartment
H Cable entry
I Sensitivity adjustment
K Light/dark switching

Electrical connection
ISO C UL US
9001 LISTED
We reserve the right to make changes • 96_b06e.fm

IP 69K
IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! M12 connectors (KD …)
! Ready-made cables (K-D …)
! Reflectors
! Reflective tapes
! Alignment aid ARH 96

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 PRK 96 M/P… - 06
www.leuze.de

– 42 –
Leuze electronic
PRK 96
Specifications Tables
Optical data
Typ. operating range limit (TK(S) 50x50) 1) 0 … 1.85m
Operating range 2) 0 … 1.5m
Light source LED (modulated light)
Wavelength 660nm (visible red light/polarised)
Timing
Switching frequency 1000Hz
Response time 0.5ms
Delay before start-up ≤ 200ms
Electrical data
Operating voltage UB 10 … 30VDC (incl. residual ripple)
Residual ripple ≤ 15% of UB
Bias current ≤ 40mA
Switching output PNP transistor
Function characteristics light/dark switching (reversible)
Signal voltage high/low ≥ (UB -2V)/≤ 2V
Output current max. 100mA
Sensitivity adjustable with 10-turn potentiometer
Indicators
LED green ready
LED yellow clear glass - adjustment range 1
transition from quickly flashing to slowly flashing
coloured glass - adjustment range 2
transition from cont. illuminated to quickly flashing
other - adjustment range 3
continuously illuminated Diagrams
Mechanical data Metal housing
Housing diecast zinc
Optics cover glass
Weight 380g
Connection type terminals or M12 connector
Environmental data
Ambient temp. (operation/storage) -20°C … +55°C/-40°C … +55°C
Protective circuit 3) 1, 2, 3, 4
VDE safety class 4) II, all-insulated
Protection class IP 67, IP 69K 5)
LED class 1 (acc. to EN 60825-1)
Standards applied IEC 60947-5-2
1) Typ. operating range limit: max. attainable range without performance reserve
2) Operating range: recommended range with performance reserve
3) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, 4=interference blanking
4) Rating voltage 250VAC
5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,
acids and bases are not part of the test

Order guide Remarks


Designation Part No. ! Integrated slit diaphragm:
3.7x20mm
With terminals PRK 96M/P-1830-21 500 28975
With M12 connector PRK 96M/P-1830-41 500 80469 Objects Adjustment
(indicator
LED yellow)
Clear glass, Range 1
PE, foil Operating pt. 1

Coloured Range 2
glass Operating pt. 2

Other Range 3

PRK 96 M/P… - 06 0603

– 43 –
Leuze electronic
PRK 96 Retro-reflective photoelectric sensors with polarisation filter
Dimensioned drawing

0 … 1.85m

20-230 V
AC / DC

! Retro-reflective photoelectric sensor for


safe detection of transparent media
(e.g. clear glass, PE, foil)
! Reliable detection of the smallest gaps
between transparent objects
! User controlled sensitivity adjustment with
high resolution
! The autocollimation principle used ensures
that the device functions reliably over the A Indicator diode green
entire range (0 … max.) B Indicator diode yellow
! All-mains design 20 … 230VAC/DC with C Optical axis
relay output D Screwed cable gland M16x1.5 for Ø 5 … 10mm
E Countersinking for SK nut M5, 4.2 deep
! Connection via comfortable terminal com-
F Connection terminals
partment up to 1.5mm²
G Cable entry
H Sensitivity adjustment
I Light/dark switching

Electrical connection
ISO C UL US
9001 LISTED
We reserve the right to make changes • 96_b07e.fm

IP 69K
IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! Spark extinction
! Reflectors
! Reflective tapes
! Alignment aid ARH 96

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 PRK 96 M/R… - 07
www.leuze.de

– 44 –
Leuze electronic
PRK 96
Specifications Tables
Optical data
Typ. operating range limit (TK(S) 50x50) 1) 0 … 1.85m
Operating range 2) 0 … 1.5m
Light source LED (modulated light)
Wavelength 660nm (visible red light/polarised)
Timing
Switching frequency 20Hz
Response time 25ms
Delay before start-up ≤ 200ms
Electrical data
Operating voltage UB 20 … 230VAC, 50/60Hz
20 … 230VDC ±10%
Power consumption ≤ 1.5VA
Switching output 3) relay, 1 change-over contact
Function characteristics light/dark switching (reversible)
Switching voltage, relay 250VAC/DC
Switching current, relay 250VAC, 3A/30VDC, 3A
Switching power, relay 750VA, cos ϕ=1
Sensitivity adjustable with 10-turn potentiometer
Indicators
LED green ready
LED yellow clear glass - adjustment range 1
transition from quickly flashing to slowly flashing
coloured glass - adjustment range 2
transition from cont. illuminated to quickly flashing
other - adjustment range 3 Diagrams
continuously illuminated
Mechanical data Metal housing
Housing diecast zinc
Optics cover glass
Weight 380g
Connection type terminals
Environmental data
Ambient temp. (operation/storage) -20°C … +55°C/-40°C … +55°C
Protective circuit 4) 1, 4
VDE safety class 5) II, all-insulated
Protection class IP 67, IP 69K 6)
LED class 1 (acc. to EN 60825-1)
Standards applied IEC 60947-5-2
Options
Switching delay (slow oper./release) 0 … 10s (separately adjustable)
1) Typ. operating range limit: max. attainable range without performance reserve
2) Operating range: recommended range with performance reserve
3) Suitable spark extinction must be provided with inductive or capacitive loads
4) 1=transient protection, 4=interference blanking
5) Rating voltage 250VAC
6) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,
acids and bases are not part of the test

Order guide Remarks


Designation Part No. ! Integrated slit diaphragm:
3.7x20mm
PRK 96M/R-1850-25 500 80470
Objects Adjustment
(indicator
LED yellow)
Clear glass, Range 1
PE, foil Operating pt. 1

Coloured Range 2
glass Operating pt. 2

Other Range 3

PRK 96 M/R… - 07 0603

– 45 –
Leuze electronic
PRK 96 Retro-reflective photoelectric sensors with polarisation filter
Dimensioned drawing

0 … 8.5m

10 - 30 V
DC

! Retro-reflective photoelectric sensor for


safe detection of transparent media
(e.g. clear glass, PE, foil)
! User controlled sensitivity adjustment with
high resolution
! The autocollimation principle used ensures
that the device functions reliably over the
entire range (0 … max.) A Indicator diode green
! High switching frequency for detection of B Indicator diode yellow
fast events C Optical axis
! Connection via M12 connector or terminal D Device plug M12x1
compartment E Screwed cable gland M16x1.5 for Ø 5 … 10mm
F Countersinking for SK nut M5, 4.2 deep
G Connection terminals
H Cable entry
I Sensitivity adjustment
K Light/dark switching

Electrical connection
ISO C UL US
9001 LISTED
We reserve the right to make changes • 96_b08e.fm

IP 69K
IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! M12 connectors (KD …)
! Ready-made cables (K-D …)
! Spark extinction
! Reflectors
! Reflective tapes
! Alignment aid ARH 96

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 PRK 96 M/P-1838-21 - 06
www.leuze.de PRK 96 M/P-1838-41 - 06

– 46 –
Leuze electronic
PRK 96
Specifications Tables
Optical data Reflectors Operating
range
Typ. operating range limit (TK(S) 50x50) 1) 0 … 8.5m
Operating range 2) see tables 1 TK(S) 100x100 0 … 7m
Light source LED (modulated light) 2 MTK(S) 50x50 0 … 6m
Wavelength 660nm (visible red light/polarised)
3 TK(S) 30x50 0 … 4m
Timing 4 TK(S) 20x40 0 … 3.5m
Switching frequency 1000Hz 5 TK(S) 82 0 … 5m
Response time 0.5ms 6 Tape 2 100x100 0 … 3m
Delay before start-up ≤ 200ms
Electrical data 1 0.1 7 8.5
Operating voltage UB 10 … 30VDC (incl. residual ripple) 2 0.1 6 7.5
Residual ripple ≤ 15% of UB 3 0.1 4 5
Bias current ≤ 40mA 4 0.1 3.5 4
Switching output PNP transistor 5 0.1 5 6
Function characteristics light/dark switching (reversible) 6 0.1 3 3.5
Signal voltage high/low ≥ (UB -2V)/≤ 2V
Output current max. 100mA Operating range [m]
Sensitivity adjustable with 10-turn potentiometer Typ. operating range limit [m]
Indicators TK … = adhesive
LED green ready TKS … = screw type
LED yellow clear glass - adjustment range 1 Tape 2 = adhesive
transition from quickly flashing to slowly flashing
coloured glass - adjustment range 2
transition from cont. illuminated to quickly flashing
other - adjustment range 3
continuously illuminated Diagrams
Mechanical data Metal housing Typ. response behaviour (TKS 100x100)
Housing diecast zinc 100
Optics cover glass

Misalignment y [mm]
80
y2
Weight 380g 60
Connection type terminals or M12 connector 40
20
Environmental data 0
-20
Ambient temp. (operation/storage) -20°C … +55°C/-40°C … +55°C -40
Protective circuit 3) 1, 2, 3, 4 -60
y1
VDE safety class 4) II, all-insulated -80
-100
Protection class IP 67, IP 69K 5) 0 2 4 6 8 10 12
LED class 1 (acc. to EN 60825-1) Distance x [m]
Standards applied IEC 60947-5-2
1) Typ. operating range limit: max. attainable range without performance reserve y2
2) Operating range: recommended range with performance reserve y1
3) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, 4=interference blanking
x
4) Rating voltage 250VAC
5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,
acids and bases are not part of the test

Order guide Remarks


Designation Part No. Objects Adjustment
(indicator
With terminals PRK 96M/P-1838-21 500 29880 LED yellow)
With M12 connector PRK 96M/P-1838-41 500 80760 Clear glass, Range 1
PE, foil Operating pt. 1

Coloured Range 2
glass Operating pt. 2

Other Range 3

PRK 96 M/P-1838-21 - 06 0603


PRK 96 M/P-1838-41 - 06

– 47 –
Leuze electronic
PRK 96 Retro-reflective photoelectric sensors with polarisation filter
Dimensioned drawing

0 … 8.5m

20-230 V
AC / DC

! Retro-reflective photoelectric sensor for


safe detection of transparent media
(e.g. clear glass, PE, foil)
! User controlled sensitivity adjustment with
high resolution
! The autocollimation principle used ensures
that the device functions reliably over the
entire range (0 … max.)
! All-mains design 20 … 230VAC/DC with A Indicator diode green
relay output B Indicator diode yellow
! Connection via comfortable terminal com- C Optical axis
partment up to 1.5mm² D Screwed cable gland M16x1.5 for Ø 5 … 10mm
E Countersinking for SK nut M5, 4.2 deep
F Connection terminals
G Cable entry
H Sensitivity adjustment
I Light/dark switching

Electrical connection
ISO C UL US
9001 LISTED
We reserve the right to make changes • 96_b09e.fm

IP 69K
IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! Spark extinction
! Reflectors
! Reflective tapes
! Alignment aid ARH 96

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 PRK 96 M/R-1858-25 - 06
www.leuze.de

– 48 –
Leuze electronic
PRK 96
Specifications Tables
Optical data Reflectors Operating
range
Typ. operating range limit (TK(S) 50x50) 1) 0 … 8.5m
Operating range 2) see tables 1 TK(S) 100x100 0 … 7m
Light source LED (modulated light) 2 MTK(S) 50x50 0 … 6m
Wavelength 660nm (visible red light/polarised)
3 TK(S) 30x50 0 … 4m
Timing 4 TK(S) 20x40 0 … 3.5m
Switching frequency 20Hz 5 TK(S) 82 0 … 5m
Response time 25ms 6 Tape 2 100x100 0 … 3m
Delay before start-up ≤ 200ms
Electrical data 1 0.1 7 8.5
Operating voltage UB 20 … 230VAC; 50/60Hz 2 0.1 6 7.5
20 … 230VDC ± 10% 3 0.1 4 5
Power consumption ≤ 1.5VA 4 0.1 3.5 4
Switching output 3) relay, 1 change-over contact 5 0.1 5 6
Function characteristics light/dark switching (reversible) 6 0.1 3 3.5
Switching voltage, relay 250VAC/DC
Switching current, relay 250VAC, 3A/30VDC, 3A Operating range [m]
Switching power, relay 750VA, cosϕ=1 Typ. operating range limit [m]
Sensitivity adjustable with 10-turn potentiometer
TK … = adhesive
Indicators TKS … = screw type
LED green ready Tape 2 = adhesive
LED yellow clear glass - adjustment range 1
transition from quickly flashing to slowly flashing
coloured glass - adjustment range 2
transition from cont. illuminated to quickly flashing
other - adjustment range 3 Diagrams
continuously illuminated
Typ. response behaviour (TKS 100x100)
Mechanical data Metal housing 100
Housing diecast zinc

Misalignment y [mm]
80
y2
Optics cover glass 60
Weight 380g 40
20
Connection type terminals 0
-20
Environmental data -40
Ambient temp. (operation/storage) -20°C … +55°C/-40°C … +55°C -60
y1
Protective circuit 4) 1, 4 -80
-100
VDE safety class 5) II, all-insulated 0 2 4 6 8 10 12
Protection class IP 67, IP 69K 6) Distance x [m]
LED class 1 (acc. to EN 60825-1)
Standards applied IEC 60947-5-2 y2
Options y1
Switching delay (slow oper./release) 0 … 10s (separately adjustable)
x
1) Typ. operating range limit: max. attainable range without performance reserve
2) Operating range: recommended range with performance reserve
3) Suitable spark extinction must be provided with inductive or capacitive loads
4) 1=transient protection, 4=interference blanking
5) Rating voltage 250VAC
6) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,
acids and bases are not part of the test

Order guide Remarks


Designation Part No. Objects Adjustment
(indicator
PRK 96M/R-1858-25 500 29881 LED yellow)
Clear glass, Range 1
PE, foil Operating pt. 1

Coloured Range 2
glass Operating pt. 2

Other Range 3

PRK 96 M/R-1858-25 - 06 0603

– 49 –
Leuze electronic
PRK 96 Retro-reflective photoelectric sensors with polarisation filter
Dimensioned drawing

18m

! Metal housing with glass cover, protection


class IP 67/IP 69K for industrial application
! Access to all sensor functions via an AS-
interface without additional wiring
! Sensitivity adjustment and ready indicator
for optimal adaptation to the application
! Common conductor for both power and data
reduces installation work
A Indicator diode green
B Indicator diode yellow
C Receiver
D Transmitter
E Optical axis
ISO C UL US F Device plug M12x1
9001 LISTED G Countersinking for SK nut M5, 4.2 deep
H Sensitivity adjustment

IP 69K
Electrical connection
IEC 60947... IEC 60947... IP 67

Accessories:
We reserve the right to make changes • 96_b10e.fm

(available separately • see page 76)


! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! M12 connectors (KD …)
! Ready-made cables (K-D …)
! Spark extinction
! Reflectors and reflective tapes

AS-i Accessories:
(available separately)
! Bus terminals
! AS-i ribbon cable
! Address programming device
! Coupling modules
! Intermediate cables etc.
Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 PRK 96 M/A-3410-44 - 08
www.leuze.de

– 50 –
Leuze electronic
PRK 96
Specifications Tables
Optical data Reflectors Operating
range
Typ. operating range limit (TK(S) 100x100) 1) 18m
Operating range 2) see tables 1 TK(S) 100x100 0.3 … 15m
Light source LED (modulated light) 2 MTK(S) 50x50 0.3 … 11m
Wavelength 660nm (visible red light, polarised)
3 TK(S) 30x50 0.3 … 6m
Timing 4 TK(S) 20x40 0.3 … 5m
Sensor switching frequency 1000Hz 5 TK(S) 82 0.3 … 11m
Sensor response time 0.5ms 6 Tape 2 100x100 0.3 … 6m
Delay before start-up ≤ 200ms
1 0.1 15 18
Electrical data 2 0.1 11 12
Operating voltage UB 26.5 … 31.6V (according to AS-i specification) 3 0.1 6 7.5
Bias current ≤ 40mA per sensor 4 0.1 5 6
Indicators 5 0.1 11 11.5
LED green ready 6 0.1 6 7.5
LED yellow light path free
LED yellow flashing light path free, no performance reserve Operating range [m]
Mechanical data Metal housing Typ. operating range limit [m]
Housing diecast zinc
Optics cover glass
Weight 380g
Connection type M12 connector
Environmental data
Ambient temp. (operation/storage) -20°C … +55°C/-40°C … +55°C
Protective circuit 3) 1, 4
VDE safety class 4) II, all-insulated
Protection class IP 67, IP 69K 5)
LED class 1 (acc. to EN 60825-1)
Standards applied IEC 60947-5-2
AS-i data for receiver
I/O code 1
ID code 1
Address programmed by the user in the range of 1 to 31
(default=0)
Cycle time acc. to AS-i specification 5ms
AS-i standard according to profile S-1.1
1) Typ. operating range limit: max. attainable range without performance reserve
2) Operating range: recommended range with performance reserve
3) 1=transient protection, 4=interference blanking Diagrams
4) Rating voltage 250VAC Typ. response behaviour (TKS 100x100)
5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,
150
acids and bases are not part of the test
Misalignment y [mm]

100
y2
Assignment: data bits Assignment: parameter bits 50

Programming Programming 0
(host level) (host level) -50
Ø no reflection Ø y1
D0 Switching out- System *P0 NC System -100
put 1 reflection input 1 parameter
-150
Ø active Ø dark switching 0 5 10 15 20
D1 Warning output System *P1 Light/dark System Distance x [m]
autoControl 1 not active input switching 1 light switching parameter
Ø sensor not ready System Ø System
D2 Ready output *P2 NC y2
1 sensor ready input 1 parameter
y1
Ø transmitter on System Ø System
*D3 Activation input output *P3 NC parameter x
1 transmitter off 1
* default = 1

Order guide
Designation Part No.
18m PRK 96M/A-3410-44 500 82067

Remarks

PRK 96 M/A-3410-44 - 08 0603

– 51 –
Leuze electronic
PRK 96 Retro-reflective photoelectric sensors with polarisation filter
Dimensioned drawing

0 … 8.5m

10 - 30 V
DC
A2 LS

! Retro-reflective photoelectric sensor for


detection of transparent media
! Robust metal housing with glass cover, pro-
tection class IP 67/IP 69K for industrial
application
! Sensitivity adjustment
! The autocollimation principle used ensures
that the device functions reliably over the
entire range (0 … max.) A Indicator diode green
B Indicator diode yellow
! High switching frequency for detection of C Optical axis
fast events D Device plug M12x1
! Connection via M12 connector or terminal E Screwed cable gland M16x1.5 for Ø 5 … 10mm
compartment F Countersinking for SK nut M5, 4.2 deep
G Connection terminals
H Cable entry
I Sensitivity adjustment

Electrical connection
ISO C UL US
9001 LISTED
We reserve the right to make changes • 96_b12e.fm

IP 69K
IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, UMS 96, BT 450.1-96)
! M12 connectors (KD …)
! Ready-made cables (K-D …)
! Reflectors
! Reflective tapes
! Alignment aid ARH 96

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 PRK 96 M/P-2838-28 (K Types) - 05
www.leuze.de PRK 96 M/P-2838-48 (K Types) - 05

– 52 –
Leuze electronic
PRK 96
Specifications Tables
Optical data Reflectors Operating
range
Typ. operating range limit (TK(S) 100x100) 1) 0 … 8.5m
Operating range 2) see tables 1 TK(S) 100x100 0 … 7m
Light source LED (modulated light) 2 MTK(S) 50x50 0 … 6m
Wavelength 660nm (visible red light/polarised)
3 TK(S) 30x50 0 … 4m
Timing 4 TK(S) 20x40 0 … 3.5m
Switching frequency 1000Hz 5 TK(S) 82 0 … 5m
Response time 0.5ms 6 Tape 2 100x100 0 … 3m
Delay before start-up ≤ 200ms
Electrical data 1 0.1 7 8.5
Operating voltage UB 10 … 30VDC (incl. residual ripple) 2 0.1 6 7.5
Residual ripple ≤ 15% of UB 3 0.1 4 5
Bias current ≤ 30mA 4 0.1 3.5 4
Switching output 2 PNP transistor outputs, complementary 5 0.1 5 6
Function characteristics light/dark switching 6 0.1 3 3.5
Signal voltage high/low ≥ (UB -2V)/≤ 2V
Output current max. 100mA Operating range [m]
Sensitivity adjustable with potentiometer Typ. operating range limit [m]
Indicators TK … = adhesive
LED yellow light path free TKS … = screw type
LED yellow flashing light path free, no performance reserve Tape 2 = adhesive
Mechanical data Metal housing
Housing diecast zinc
Optics cover glass
Weight 380g
Connection type terminals or M12 connector Diagrams
Environmental data Typ. response behaviour (TKS 100x100)
Ambient temp. (operation/storage) -20°C … +55°C/-40°C … +55°C 100
Protective circuit 3)

Misalignment y [mm]
80
1, 2, 3, 4 60
y2
VDE safety class 4) II, all-insulated 40
Protection class IP 67, IP 69K 5) 20
LED class 1 (acc. to EN 60825-1) 0
-20
Standards applied IEC 60947-5-2 -40
-60
y1
1) Typ. operating range limit: max. attainable range without performance reserve -80
2) Operating range: recommended range with performance reserve -100
0 2 4 6 8 10 12
3) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, 4=interference blanking Distance x [m]
4) Rating voltage 250VAC
5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,
acids and bases are not part of the test y2
y1

Order guide Remarks


Designation Part No.
With terminals PRK 96M/P-2838-28 500 82060
With M12 connector PRK 96M/P-2838-48 (optional)

PRK 96 M/P-2838-28 (K Types) - 05 0603


PRK 96 M/P-2838-48 (K Types) - 05

– 53 –
Leuze electronic
RT 96 Energetic diffuse reflection light scanners
Dimensioned drawing

30 … 700mm
20 … 1200mm
10 - 30 V
DC
A2 LS

! Robust metal housing with glass cover or


plastic housing, protection class IP 67/
IP 69K for industrial application
! Sensitivity adjustment and delay before
start-up for optimal adaptation to the
A Indicator diode green
application
B Indicator diode yellow
! Minimal short range C Receiver
! Connection via M12 connector or terminal D Transmitter
compartment E Optical axis
F Device plug M12
! Multiple options with warning output,
G Screwed cable gland M16x1.5 for Ø 5 … 10mm
activation input, switching delays and optics
H Countersinking for SK nut M5, 4.2 deep
heating for use at low temperatures
I Connection terminals
K Cable entry
L Sensitivity adjustment

Electrical connection
ISO C UL US
9001 LISTED
We reserve the right to make changes • 96_c01e.fm

IP 69K
IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! M12 connectors (KD …)
! Ready-made cables (K-D …)

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 RT 96 M/P… - 08
www.leuze.de

– 54 –
Leuze electronic
RT 96
Specifications Tables
Optical data Infrared light Red light Red light
Typ. scanning range limit (white 90%) 1) 20 … 1200mm 30 … 700mm 1 30 500 700
Scanning range 2) 20 … 800mm 30 … 500mm 2 65 320 430
Adjustment range 0 … 100% 0 … 100% 3 90 200 370
Light source LED (modulated light) LED (modulated light)
Wavelength 880nm 660nm Infrared light
1 20 800 1200
Timing 2 60 420 950
Switching frequency 1000Hz
3 80 290 570
Response time 0.5ms
Delay before start-up ≤ 200ms
1 white 90%
Electrical data 2 grey 18%
Operating voltage UB 10 … 30VDC (incl. residual ripple) 3 black 6%
Residual ripple ≤ 15% of UB
Bias current ≤ 40mA, ≤ 75mA with optics heating Scanning range [mm]
Switching output PNP transistor Typ. scanning range limit [mm]
Function characteristics light switching
Signal voltage high/low ≥ (UB -2V)/≤ 2V
Output current max. 100mA
Sensitivity adjustable
Indicators
Diagrams
LED green ready Red light
LED yellow reflection Typ. response behaviour (white 90%)
LED yellow flashing reflection, no performance reserve 8
6
Mechanical data Metal housing

Misalignment y [mm]
4
Housing diecast zinc y1
2
Optics cover glass
0
Weight 380g
Connection type terminals or M12 connector -2
y2
-4
Environmental data -6
Ambient temp. (operation/storage) -20°C … +60°C/-40°C … +70°C -8
Protective circuit 3) 1, 2, 3, 4 0 100 200 300 400 500 600 700
Distance x [mm]
VDE safety class 4) II, all-insulated
Protection class IP 67, IP 69K 5) Infrared light
LED class 1 (acc. to EN 60825-1) Typ. response behaviour (white 90%)
Standards applied IEC 60947-5-2 20

Misalignment y [mm]
y1
Options 15
Warning output autoControl warn PNP transistor, 100mA, counting principle 10
Optics heating for temperature changes, prevents fogging 5
Low temperature to -35°C 0
Switching delay (slow oper./release) 0 … 10s (separately adjustable) -5
-10
1) Typ. scanning range limit: max. attainable range without performance reserve -15
2) Scanning range: recommended range with performance reserve y2
-20
3) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, 4=interference blanking 0 300 600 900 1200
4) Rating voltage 250VAC Distance x [mm]
5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,
acids and bases are not part of the test y2
y1

Order guide Remarks


Selection table ! The upper and lower scan-
RT 96M/P-1374-500-42

RT 96M/P-1474-800-42

ning range limit varies


Part No. 500 41596

Part No. 500 41597

depending on the reflec-


tion properties of the
Order code "
material surface.
! Short range
objects are detected down
Equipment #
to a minimum distance of
Housing metal ! ! 20mm.
plastic
Light source red light (500mm) !
infrared light (800mm) !
Connection terminals
M12 connector ! !
Features optics heating/low temp.
switching delay !
warning output ! !
short range (20mm) ! !
NPN switching output

RT 96 M/P… - 08 0603

– 55 –
Leuze electronic
RT 96 Energetic diffuse reflection light scanners
Dimensioned drawing

20 … 1200mm

10 - 30 V
DC
A2 LS

! Robust metal housing with glass cover or


plastic housing, protection class IP 67 for
industrial application
! Complementary outputs, sensitivity
adjustment and delay before start-up for
A Indicator diode green
optimal adaptation to the application
B Indicator diode yellow
! Minimal short range C Receiver
! Connection via M12 connector or terminal D Transmitter
compartment E Optical axis
F Device plug M12
G Screwed cable gland M16x1.5 for Ø 5 … 10mm
H Countersinking for SK nut M5, 4.2 deep
I Connection terminals
K Cable entry
L Sensitivity adjustment

Electrical connection
ISO C UL US
9001 LISTED
We reserve the right to make changes • 96_c05e.fm

IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! M12 connectors (KD …)
! Ready-made cables (K-D …)

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 RT 96 K/P… - 08
www.leuze.de

– 56 –
Leuze electronic
RT 96
Specifications Tables
1 20 800 1200
Optical data Infrared light
2 60 420 950
Typ. scanning range limit (white 90%) 1) 20 … 1200mm
Scanning range 2) 20 … 800mm 3 80 290 570
Adjustment range 0 … 100%
Light source LED (modulated light) 1 white 90%
Wavelength 880nm 2 grey 18%
3 black 6%
Timing
Switching frequency 1000Hz Scanning range [mm]
Response time 0.5ms Typ. scanning range limit [mm]
Delay before start-up ≤ 200ms
Electrical data
Operating voltage UB 10 … 30VDC (incl. residual ripple)
Residual ripple ≤ 15% of UB
Bias current ≤ 40mA
Switching output PNP transistor
Function characteristics light/dark switching
Signal voltage high/low ≥ (UB -2V)/≤ 2V
Output current max. 100mA
Sensitivity adjustable
Indicators
Diagrams
Typ. response behaviour (white 90%)
LED green ready
20
LED yellow reflection

Misalignment y [mm]
y1
15
LED yellow flashing reflection, no performance reserve
10
Mechanical data Plastic housing 5
Housing polycarbonate 0
Optics cover plastic -5
Weight 150g -10
Connection type terminals or M12 connector -15
y2
Environmental data -20
0 300 600 900 1200
Ambient temp. (operation/storage) -20°C … +60°C/-40°C … +70°C Distance x [mm]
Protective circuit 3) 1, 2, 3, 4
VDE safety class 4) II, all-insulated y2
Protection class IP 67
y1
LED class 1 (acc. to EN 60825-1)
Standards applied IEC 60947-5-2 x

1) Typ. scanning range limit: max. attainable range without performance reserve
2) Scanning range: recommended range with performance reserve
3) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, 4=interference blanking
4) Rating voltage 250VAC

Order guide Remarks


! The upper and lower scan-
RT 96K/P-1444.1-800-41

Selection table
RT 96K/N-1444-800-46
RT 96K/P-1444-800-21

RT 96K/P-1444-800-41

ning range limit varies


Part No. 500 81177

Part No. 500 81178

Part No. 500 41595

Part No. 501 03585

depending on the reflec-


tion properties of the
Order code "
material surface.
! Short range
objects are detected down
Equipment #
to a minimum distance of
Housing metal 20mm.
plastic ! ! ! ! ! * For direct connection to
Light source red light (500mm) AS-i I/O coupling modules
infrared light (800mm) ! ! ! !
Connection terminals !
M12 connector ! ! !
Features switching delay
warning output
short range (20mm) ! ! ! !
NPN switching output !
PIN 2 = NC * !
PIN 4 = light/dark reversible !

RT 96 K/P… - 08 0603

– 57 –
Leuze electronic
RT 96 Energetic diffuse reflection light scanners
Dimensioned drawing

20 … 1200mm

20-230 V
AC / DC
A2 LS

! Robust metal housing with glass cover or


plastic housing, protection class IP 67/
IP 69K for industrial application
! Relay with change-over contact, sensitivity
adjustment and delay before start-up for
optimal adaptation to the application A Indicator diode green
! Minimal short range B Indicator diode yellow
C Receiver
! Version with additional switching delay
D Transmitter
! Connection via comfortable terminal com- E Optical axis
partment up to 1.5mm² F Screwed cable gland M16x1.5 for Ø 5 … 10mm
G Countersinking for SK nut M5, 4.2 deep
H Connection terminals
I Cable entry
K Sensitivity adjustment

Electrical connection
ISO C UL US
9001 LISTED
We reserve the right to make changes • 96_c02e.fm

IP 69K
IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! Spark extinction

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 RT 96 M/R… - 08
www.leuze.de

– 58 –
Leuze electronic
RT 96
Specifications Tables
1 20 800 1200
Optical data
2 60 420 950
Typ. scanning range limit (white 90%) 1) 20 … 1200mm
Scanning range 2) 20 … 800mm 3 80 290 570
Adjustment range 0 … 100%
Light source LED (modulated light) 1 white 90%
Wavelength 880nm (infrared) 2 grey 18%
3 black 6%
Timing
Switching frequency 20Hz Scanning range [mm]
Response time 25ms Typ. scanning range limit [mm]
Delay before start-up ≤ 200ms
Electrical data
Operating voltage UB 20 … 230VAC, 50/60Hz
20 … 230VDC
Power consumption ≤ 2VA
Switching output 3) relay, 1 change-over contact
Function characteristics break-contact/make-contact
Switching voltage, relay 250VAC/DC
Switching current, relay 250VAC, 3A/30VDC, 3A
Switching power 750VA, cosϕ=1
Diagrams
Indicators
Typ. response behaviour (white 90%)
LED green ready
20
LED yellow reflection

Misalignment y [mm]
y1
15
LED yellow flashing reflection, no performance reserve
10
Mechanical data Metal housing 5
Housing diecast zinc 0
Optics cover glass -5
Weight 380g -10
Connection type terminals -15
y2
Environmental data -20
0 300 600 900 1200
Ambient temp. (operation/storage) -20°C … +60°C/-40°C … +70°C Distance x [mm]
Protective circuit 4) 1, 4
VDE safety class 5) II, all-insulated y2
Protection class IP 67, IP 69K 6)
y1
LED class 1 (acc. to EN 60825-1)
Standards applied IEC 60947-5-2 x

Options
Switching delay (slow oper./release) 0 … 10s (separately adjustable)
1) Typ. scanning range limit: max. attainable range without performance reserve
2) Scanning range: recommended range with performance reserve
3) Suitable spark extinction must be provided with inductive or capacitive loads
4) 1=transient protection, 4=interference blanking
5) Rating voltage 250VAC
6) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,
acids and bases are not part of the test

Order guide Remarks


Selection table ! The upper and lower scan-
RT 96M/R-1574-800-25

ning range limit varies


Part No. 500 41598

depending on the reflec-


tion properties of the
Order code " material surface.
! Short range
objects are detected down
Equipment # to a minimum distance of
Housing metal ! 20mm.
plastic
Light source red light (500mm)
infrared light (800mm) !
Connection terminals !
Features switching delay !
short range (20mm) !

RT 96 M/R… - 08 0603

– 59 –
Leuze electronic
HRT 96 Diffuse reflection light scanner with background suppression
Dimensioned drawing

100 … 1800mm
100 … 1200mm

10 - 30 V
DC
A2 LS

! Scanner with adjustable background sup-


pression in visible red light or infrared light
! Robust metal housing with glass cover or
plastic housing, protection class IP 67/
IP 69K for industrial application
! Complementary outputs, scanning range A Indicator diode green
adjustment and delay before start-up for B Indicator diode yellow
optimal adaptation to the application C Transmitter
! Connection via M12 connector or terminal D Receiver
compartment E Optical axis
F Device plug M12x1
! Multiple options with switching delays, acti- G Screwed cable gland M16x1.5 for Ø 5 … 10mm
vation input and optics heating for use at low H Countersinking for SK nut M5, 4.2 deep
temperatures I Connection terminals
K Cable entry
L Scanning range adjustment
Preferred entry direction for objects $ + %

Electrical connection
ISO C UL US
We reserve the right to make changes • 96_d01e.fm

9001 LISTED

IP 69K
IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! M12 connectors (KD …)
! Ready-made cables (K-D …)

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 HRT 96 M/P… - 09
www.leuze.de

– 60 –
Leuze electronic
HRT 96
Specifications Tables
Optical data Infrared light Red light Red light
Typ. scanning range limit (white 90%) 1) 100 … 1800mm 100 … 1200mm 1 100 800 1200
Scanning range 2) see tables see tables 2 100 770 1140
Adjustment range 150 … 1200mm 100 … 800mm 3 100 730 1050
Light source LED (modulated light) LED (modulated light)
Wavelength 880nm 660nm Infrared light
1 100 1200 1800
Timing 2 100 1100 1600
Switching frequency 300Hz
3 100 1000 1350
Response time 1.67ms
Delay before start-up ≤ 200ms
1 white 90%
Electrical data 2 grey 18%
Operating voltage UB 10 … 30VDC (incl. residual ripple) 3 black 6%
Residual ripple ≤ 15% of UB
Bias current ≤ 35mA, ≤ 75mA with optics heating Scanning range [mm]
Switching output PNP transistor Typ. scanning range limit [mm]
Function characteristics light or dark switching (reversible)
Signal voltage high/low ≥ (UB -2V)/≤ 2V
Output current max. 100mA Diagrams
Indicators Red light
LED green ready Typ. response behaviour (white 90%)
LED yellow reflection 8
Mechanical data Metal housing 6

Misalignment y [mm]
Housing diecast zinc 4
y2
Optics cover glass 2
Weight 380g 0
Connection type terminals or M12 connector -2
y1
Environmental data -4

Ambient temp. (operation/storage) -20°C … +60°C/-40°C … +70°C -6


Protective circuit 3) 1, 2, 3, 4 -8
0 200 400 600 800 1000 1200
VDE safety class 4) II, all-insulated Distance x [mm]
Protection class IP 67, IP 69K 5)
LED class 1 (acc. to EN 60825-1) Infrared light
Standards applied IEC 60947-5-2 Typ. response behaviour (white 90%)
10
Options 8
Optics heating for temperature changes, prevents fogging y2

Misalignment y [mm]
6
Low temperature to -35°C 4
Switching delay (slow oper./release) 0 … 10s (separately adjustable) 2
Activation input activ 0

Transmitter active/not active ≥ 8V/≤ 2V -2


-4
Activation/disable delay ≤ 0.5ms -6
y1
Input resistance 47KΩ ± 10% -8
-10
1) Typ. scanning range limit: max. attainable range without performance reserve 0 300 600 900 1200 1500 1800

2) Scanning range: recommended range with performance reserve Distance x [mm]


3) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, 4=interference blanking
4) Rating voltage 250VAC
y2
5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,
y1
acids and bases are not part of the test
x
Remarks Red light
! With the set scanning range, a tolerance of the upper scanning range limit is possible depending on the Typ. black/white behaviour
reflection properties of the material surface. 140
Red. of scan range y [mm]

! The diffuse reflection light scanner is also available with integrated AS-i chip for direct connection to the 120
A
AS-i system. B
100 C

Order guide 80
60
HRT 96M/N-1606-1200-27
HRT 96M/P-1610-1200-21

HRT 96M/P-1610-1200-41

HRT 96M/P-1620-1200-21

HRT 96M/P-1620-1200-41

Selection table
HRT 96M/P-1630-800-41

HRT 96M/P-1636-800-41

HRT 96M/P-1640-800-21

HRT 96M/P-1640-800-41

HRT 96M/P-1635-800-45

40
20
Part No. 500 80047

Part No. 500 32127

Part No. 500 25124

Part No. 500 25126

Part No. 501 04142

Part No. 500 25116

Part No. 500 25118

Part No. 500 25114

Part No. 500 61102

Part No. 500 40358

0
0 200 400 600 800 1000 1200
Scanning range x [mm]
Order code "
Infrared light
Typ. black/white behaviour
500
Red. of scan range y [mm]

Equipment # 450
400
A
B
Light source red light (800mm) ! ! ! ! ! 350
300
C

infrared light (1200mm) ! ! ! ! ! 250


200
Connection terminals ! ! ! ! 150
100
M12 connector ! ! ! ! ! ! 50
0
Features optics heating/low temp. ! ! ! ! 0 300 600 900
Scanning range x [mm]
1200 1500 1800

switching delay ! ! ! ! ! !
A white 90% y
activation input B grey 18%
NPN switching output ! C black 6%
x
for AS-i I/O coupling modules !
HRT 96 M/P… - 09 0603

– 61 –
Leuze electronic
HRT 96 Diffuse reflection light scanner with background suppression
Dimensioned drawing

100 … 1800mm
100 … 1200mm

10 - 30 V
DC
A2 LS

! Scanner with adjustable background sup-


pression in visible red light or infrared light
! Robust metal housing with glass cover or
plastic housing, protection class IP 67 for
industrial application
! Complementary outputs for standard appli- A Indicator diode green
cations and a wide range of input and output B Indicator diode yellow
variants for optimum adaptation to the C Transmitter
application D Receiver
! Connection via M12 connector or terminal E Optical axis
compartment F Device plug M12x1
G Screwed cable gland M16x1.5 for Ø 5 … 10mm
! Various options with switching delays, light/ H Countersinking for SK nut M5, 4.2 deep
dark switching, activation input, and optics I Connection terminals
heating combined with low temperature K Cable entry
L Scanning range adjustment
Preferred entry direction for objects $ + %

Electrical connection
ISO C UL US
9001 LISTED
We reserve the right to make changes • 96_d09e.fm

IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! M12 connectors (KD …)
! Ready-made cables (K-D …)

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 HRT 96 K/P… - 10
www.leuze.de

– 62 –
Leuze electronic
HRT 96
Specifications Tables
Optical data Infrared light Red light Red light
Typ. scanning range limit (white 90%) 1) 100 … 1800mm 100 … 1200mm 1 100 800 1200
Scanning range 2) see tables see tables 2 100 770 1140
Adjustment range 150 … 1200mm 100 … 800mm 3 100 730 1050
Light source LED (modulated light) LED (modulated light)
Wavelength 880nm 660nm Infrared light
1 100 1200 1800
Timing 2 100 1100 1600
Switching frequency 300Hz
3 100 1000 1350
Response time 1.67ms
Delay before start-up ≤ 200ms
1 white 90%
Electrical data 2 grey 18%
Operating voltage UB 10 … 30VDC (incl. residual ripple) 3 black 6%
Residual ripple ≤ 15% of UB
Bias current ≤ 35mA Scanning range [mm]
Switching output PNP transistor Typ. scanning range limit [mm]
Function characteristics light or dark switching
Signal voltage high/low ≥ (UB -2V)/≤ 2V
Output current max. 100mA Diagrams
Indicators Red light
LED green ready Typ. response behaviour (white 90%)
LED yellow reflection 8
Mechanical data Plastic housing 6

Misalignment y [mm]
Housing polycarbonate 4
y2
Optics cover plastic 2
Weight 150g 0
Connection type terminals or M12 connector -2
y1
Environmental data -4

Ambient temp. (operation/storage) -20°C … +60°C/-40°C … +70°C -6


Protective circuit 3) 1, 2, 3, 4 -8
0 200 400 600 800 1000 1200
VDE safety class 4) II, all-insulated Distance x [mm]
Protection class IP 67
LED class 1 (acc. to EN 60825-1) Infrared light
Standards applied IEC 60947-5-2 Typ. response behaviour (white 90%)
10
Options 8
Switching delay (slow oper./release) 0 … 10s (separately adjustable) y2

Misalignment y [mm]
6
Activation input activ (high) 4
Transmitter active/not active ≥ 8V/≤ 2V 2
Activation/disable delay ≤ 0.5ms 0
-2
Input resistance 47KΩ ± 10% -4
-6
1) Typ. scanning range limit: max. attainable range without performance reserve -8
y1
2) Scanning range: recommended range with performance reserve -10
3) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, 4=interference blanking 0 300 600 900 1200 1500 1800

4) Rating voltage 250VAC Distance x [mm]

Remarks y2
! With the set scanning range, a tolerance of the upper scanning range limit is possible depending on the reflection properties y1
of the material surface.
! The diffuse reflection light scanner is also available with integrated AS-i chip for direct connection to the AS-i system. x

! * For direct connection to AS-i I/O coupling modules


Red light
! Available as a set together with cable socket
Typ. black/white behaviour
Order guide 140
Red. of scan range y [mm]

A
120
B
HRT 96K/P-1600.1-1200-41

Selection table 100 C


HRT 96K/P-1600-1200-21

HRT 96K/P-1600-1200-41

HRT 96K/P-1605-1200-45

HRT 96K/P-1607-1200-49
HRT 96K/P-1630-800-41

HRT 96K/P-1630-800-21

HRT 96K/P-1640-800-41

HRT 96K/P-1631-800-47

80
60
Part No. 500 80242

Part No. 500 25135

Part No. 500 25133

Part No. 500 80327

Part No. 500 81464

Part No. 500 38471

Part No. 501 03002

Part No. 501 03090

Part No. 501 03217

40
Order code " 20
0
0 200 400 600 800 1000 1200
Scanning range x [mm]

Equipment # Infrared light


Typ. black/white behaviour
Light source red light (800mm) ! ! ! ! 500
Red. of scan range y [mm]

450 A
infrared light (1200mm) ! ! ! ! ! 400 B
350 C
Connection terminals ! ! 300
250
M12 connector ! ! ! ! ! ! ! 200

Features switching delay ! 150


100
activation input ! 50
0
0 300 600 900 1200 1500 1800
PIN 2 = NC * ! ! ! Scanning range x [mm]
PIN 4 = dark switching !
A white 90%
PIN 4 = light switching ! B grey 18%
y

PIN 4 = light/dark reversible ! C black 6%


x
UL homologation ! ! ! ! ! ! ! ! !
HRT 96 K/P… - 10 0603

– 63 –
Leuze electronic
HRT 96 Diffuse reflection light scanner with background suppression
Dimensioned drawing

100 … 1800mm

20-230 V
AC / DC
A2 LS

! Scanner with adjustable background sup-


pression in infrared light
! Robust metal housing with glass cover or
plastic housing, protection class IP 67/
IP 69K for industrial application
! All-mains design 20 … 230VAC/DC with
relay output A Indicator diode green
B Indicator diode yellow
! Relay with change-over contact, scanning
C Transmitter
range adjustment and delay before start-up
D Receiver
for optimal adaptation to the application
E Optical axis
! Connection via comfortable terminal com- F Screwed cable gland M16x1.5 for Ø 5 … 10mm
partment up to 1.5mm² G Countersinking for SK nut M5, 4.2 deep
! Version with additional switching delay H Connection terminals
I Cable entry
K Scanning range adjustment
Preferred entry direction for objects $ + %

Electrical connection
ISO C UL US
9001 LISTED
We reserve the right to make changes • 96_d02e.fm

IP 69K
IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! Spark extinction

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 HRT 96 K/R… - 09
www.leuze.de HRT 96 M/R… - 09

– 64 –
Leuze electronic
HRT 96
Specifications Tables
1 100 1200 1800
Optical data Infrared light
2 100 1100 1600
Typ. scanning range limit (white 90%) 1) 100 … 1800mm
Scanning range 2) see tables 3 100 1000 1350
Adjustment range 150 … 1200mm
Light source LED (modulated light) 1 white 90%
Wavelength 880nm (infrared) 2 grey 18%
3 black 6%
Timing
Switching frequency 20Hz Scanning range [mm]
Response time 25ms Typ. scanning range limit [mm]
Delay before start-up ≤ 200ms
Electrical data
Operating voltage UB 20 … 230VAC, 50/60Hz
20 … 230VDC
Power consumption ≤ 1.5VA
Switching output 3) relay, 1 change-over contact
Function characteristics break-contact/make-contact
Switching voltage, relay 250VAC/DC
Switching current, relay 250VAC, 3A/30VDC, 3A
Switching power, relay 750VA, cosϕ=1
Diagrams
Indicators
Typ. response behaviour (white 90%)
LED green ready
10
LED yellow reflection 8

Misalignment y [mm]
y2
Mechanical data Metal housing Plastic housing 6
4
Housing diecast zinc polycarbonate 2
Optics cover glass plastic 0
Weight 380g 150g -2
Connection type terminals terminals -4
-6
y1
Environmental data -8
Ambient temp. (operation/storage) -20°C … +60°C/-40°C … +70°C -10
0 300 600 900 1200 1500 1800
Protective circuit 4) 1, 4 Distance x [mm]
VDE safety class 5) II, all-insulated
Protection class IP 67, IP 69K 6) IP 67 y2
LED class 1 (acc. to EN 60825-1)
y1
Standards applied IEC 60947-5-2
Options x

Switching delay (slow oper./release) 0 … 10s (separately adjustable) Typ. black/white behaviour
500
1) Typ. scanning range limit: max. attainable range without performance reserve
Red. of scan range y [mm]
450 A
2) Scanning range: recommended range with performance reserve 400 B
3) Suitable spark extinction must be provided with inductive or capacitive loads 350 C
4) 1=transient protection, 4=interference blanking 300
250
5) Rating voltage 250VAC 200
6) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, 150
acids and bases are not part of the test 100
50
0
0 300 600 900 1200 1500 1800
Scanning range x [mm]

A white 90%
B grey 18%
C black 6%

Order guide
x
Selection table
HRT 96M/R-1680-1200-25

HRT 96M/R-1690-1200-25

HRT 96M/R-1689-1200-25
HRT 96K/R-1680-1200-25

HRT 96K/R-1690-1200-25
Part No. 500 25132

Part No. 500 25131

Part No. 500 80076

Part No. 500 80075

Part No. 500 81261

Order code "

Remarks
Equipment # ! With the set scanning
Housing metal ! ! range, a tolerance of the
upper scanning range limit
plastic ! ! ! is possible depending on
Light source infrared light (1200mm) ! ! ! ! ! the reflection properties of
Connection terminals ! ! ! ! ! the material surface.
without screwed cable gland !
Features switching delay ! !

HRT 96 K/R… - 09 0603


HRT 96 M/R… - 09

– 65 –
Leuze electronic
HRT 96 Diffuse reflection light scanner with background suppression
Dimensioned drawing

100 … 1800mm
100 … 1200mm

! Robust metal housing with glass cover, pro-


tection class IP 67/IP 69K for industrial
application
! Access to all sensor functions via an AS-
interface without additional wiring A Indicator diode green
B Indicator diode yellow
! Scanning range adjustment and ready indi-
C Receiver
cator for optimal adaptation to the
D Transmitter
application
E Optical axis
! Common conductor for both power and data F Device plug M12x1
reduces installation work G Countersinking for SK nut M5, 4.2 deep
H Scanning range adjustment
Preferred entry direction for objects $ + %

Electrical connection
ISO C UL US
9001 LISTED

IP 69K
IEC 60947...
We reserve the right to make changes • 96_d03e.fm

IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! M12 connectors (KD …)
! Ready-made cables (K-D …)

AS-i Accessories:
(available separately)
! Bus terminals
! AS-i ribbon cable
! Address programming device
! Coupling modules
! Intermediate cables etc.

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 HRT 96M/A-1660-1200-44 - 08
www.leuze.de HRT 96M/A-1670-800-44 - 08

– 66 –
Leuze electronic
HRT 96
Specifications Tables
Optical data Infrared Red light Red light
Typ. scanning range limit (white 90%) 1) 100 … 1800mm 100 … 1200mm 1 100 800 1200
Scanning range 2) see tables see tables 2 100 770 1140
Adjustment range 150 … 1200mm 100 … 800mm 3 100 730 1050
Light source LED (modulated light) LED (modulated light)
Wavelength 880nm (infrared) 660nm Infrared light
1 100 1200 1800
Timing 2 100 1100 1600
Sensor switching frequency 300Hz
3 100 1000 1350
Sensor response time 1.67ms
Delay before start-up ≤ 200ms
1 white 90%
Electrical data 2 grey 18%
Operating voltage UB 26.5 … 31.6V (according to AS-i specification) 3 black 6%
Bias current ≤ 40mA per sensor
Indicators Scanning range [mm]
LED green ready Typ. scanning range limit [mm]
LED yellow reflection
Mechanical data Metal housing Diagrams
Housing diecast zinc
Red light
Optics cover glass
Weight 380g Typ. response behaviour (white 90%)
Connection type M12 connector 8
6

Misalignment y [mm]
Environmental data 4
Ambient temp. (operation/storage) -20°C … +60°C/-40°C … +70°C 2
y2
Protective circuit 3) 1, 4
0
VDE safety class 4) II, all-insulated
Protection class IP 67, IP 69K 5) -2
y1
LED class 1 (acc. to EN 60825-1) -4

Standards applied IEC 60947-5-2 -6


-8
AS-i data for receiver 0 200 400 600 800 1000 1200
I/O code 1 Distance x [mm]
ID code 1
Infrared light
Address programmed by the user in the range of 1 to 31
(default=0) Typ. response behaviour (white 90%)
Cycle time acc. to AS-i specification 5ms 10
8
AS-i standard according to profile S-1.1

Misalignment y [mm]
y2
6
4
1) Typ. scanning range limit: max. attainable range without performance reserve 2
2) Scanning range: recommended range with performance reserve 0
3) 1=transient protection, 4=interference blanking -2
4) Rating voltage 250VAC -4
5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, -6
y1
-8
acids and bases are not part of the test
-10
0 300 600 900 1200 1500 1800
Distance x [mm]

Assignment: data bits Assignment: parameter bits


y2
Programming Programming
y1
(host level) (host level)
Switching out- Ø no reflection System Ø System x
D0 put input *P0 NC parameter
1 reflection 1
Red light
Ø System Light/dark Ø dark switching System Typ. black/white behaviour
D1 NC input *P1 switching parameter
1 1 light switching 140
Red. of scan range y [mm]

A
Ø sensor not ready System Ø System 120
D2 Ready output *P2 NC B
1 sensor ready input 1 parameter 100 C

Ø transmitter on System Ø System 80


*D3 Activation input *P3 NC
1 transmitter off output 1 parameter 60

* default = 1 40
20
0
0 200 400 600 800 1000 1200
Scanning range x [mm]
Remarks Infrared light
! With the set scanning range, a tolerance of the upper scanning range limit is possible depend- Typ. black/white behaviour
500
Red. of scan range y [mm]

ing on the reflection properties of the material surface. 450 A


400 B
350 C
300
Order guide 250
200
150
Designation Part No. 100
50
Infrared light HRT 96M/A-1660-1200-44 500 25112 0
0 300 600 900 1200 1500 1800
Red light HRT 96M/A-1670-800-44 500 80048 Scanning range x [mm]

A white 90% y
B grey 18%
C black 6%
x

HRT 96M/A-1660-1200-44 - 08 0603


HRT 96M/A-1670-800-44 - 08

– 67 –
Leuze electronic
HRT 96 Diffuse reflection light scanner with background suppression
Dimensioned drawing

100 … 2500mm

10 - 30 V
DC

! Scanner with adjustable background


suppression
! Two switching points
! Individual adaptation to applications by A Indicator diode green
means of programming and diagnosis B Indicator diode yellow
software C Transmitter
! Universal sensor application through D Receiver
optional foreground suppression or exact E Optical axis
edge detection F Device plug M12x1
! General light/dark switching or complemen- G Screwed cable gland M16x1.5 for Ø 5 … 10mm
tary switching output, scanning range H Countersinking for SK nut M5, 4.2 deep
adjustment and delay before start-up for I Output with option switching delay
optimal adaptation to the application K Connection terminals
L Cable entry
! Robust metal housing with glass cover, pro- M Scanning range adjustment
tection class IP 67/IP 69K for industrial N Light/dark switching
application Preferred entry direction for objects $ + %

Electrical connection
ISO C UL US
We reserve the right to make changes • 96_d06e.fm

9001 LISTED

IP 69K
IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76) Close
! Mounting systems
(BT 96, BT 96.1, BT 450.1-96, UMS 96) Remote
! Programming device UPG-2,
Programming software
see remarks !
! M12 connectors (KD …)
! Ready-made cables (K-D …)

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 HRT 96 M/P-1600-2000-42 - 05
www.leuze.de HRT 96 M/P-3604-2000-42 - 05

– 68 –
Leuze electronic
HRT 96
Specifications Tables
Optical data 1 100 2000 2500
HRT...1600... HRT...3604...
2 100 1990 2470
Typ. scanning range limit (white 90%) 1) 100 … 2500mm 10 … 2500mm
Scanning range 2) see tables see tables 3 100 1980 2430
Adjustment range 150 … 2000mm 150 … 2000mm
Light source LED (modulated light) 1 white 90%
Wavelength 880nm 2 grey 18%
3 black 6%
Timing
Switching frequency 300Hz Scanning range [mm]
Response time 1.67ms Typ. scanning range limit [mm]
Delay before start-up ≤ 200ms
Electrical data Light switching
Operating voltage UB 10 … 30VDC (incl. residual ripple) Switching LED LED LED
Residual ripple ≤ 15% of UB points red green yellow
Bias current ≤ 35mA no detection on off off
Switching output PNP transistor (reflection on
Function characteristics light/dark switching (reversible) background)
Signal voltage high/low ≥ (UB -2V)/≤ 2V detection dis- off on on
Output current max. 100mA tant range
detection on on on
Indicators close range
Sensor front
LED green ready ready Dark switching
LED yellow reflection ! LED red/green:
Sensor back
LED red/green see table reflection see Light switching
Mechanical data Metal housing ! LED yellow:
Housing diecast zinc inverted
Optics cover glass
Weight 380g
Connection type terminals or M12 connector
Environmental data
Ambient temp. (operation/storage) -20°C … +60°C/-40°C … +70°C
Protective circuit 3) 1, 2, 3, 4
VDE safety class 4) II, all-insulated
Protection class IP 67, IP 69K 5)
LED class 1 (acc. to EN 60825-1) Remarks
Standards applied IEC 60947-5-2 ! General
Options With the set scanning range,
Switching delay (slow oper./release) 0 … 10s (separately adjustable) a tolerance of the upper scan-
ning range limit is possible de-
1) Typ. scanning range limit: max. attainable range without performance reserve pending on the reflection
2) Scanning range: recommended range with performance reserve properties of the material sur-
3) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, 4=interference blanking
4) Rating voltage 250VAC
face.
5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are ! Reference scanner
not part of the test
Scanner for safe detection of
Diagrams objects under most difficult
environmental conditions
Typ. response behaviour (white 90%) Typ. black/white behaviour
(e. g. black object on white
Red. of scan range y [mm]

20 160
A background).
Misalignment y [mm]

15 140
10
y2
120
B
C A white 90% Is set through re-parameteri-
5 100 B grey 18% sation of the standard
0 y2 80 C black 6% HRT 96…3604… sensor via
-5 y1 60 Software "Lupo".
y
-10
y1 x
40
HRT 96…3604…
-15 20
-20
0 0,5 1 1,5 2 2,5 3
0
0 0,5 1 1,5 2 2,5 3 x ! Switching
Distance x [m] Scanning range x [m] points
Fixed ratio between short and
distant range
Order guide s.r. ~0.5xd.r. Adjusting the
distant range also sets the
Selection table
HRT 96M/P-1600-2000-42

HRT 96M/P-3604-2000-42

short range.
! Switching output
Pin/terminal
Part No. 500 60857

Part No. 500 60858

4/3=distant range
Order code " 2/4=short range (standard)
2/4=programmable
(e.g. activation input, compl.
switching output)
Equipment # HRT 96…1600…
Housing metal ! ! ! Switching output
Pin/terminal
Light source infrared light (2000mm) ! ! 4/3=switching output
Connection M12 connector ! ! 2/4=compl. switching output
Features short range ! ! Available as a set together
with cable socket KD 095
2 switching points !
switching delay ! !
complementary switching outputs !
HRT 96 M/P-1600-2000-42 - 05 0603
HRT 96 M/P-3604-2000-42 - 05

– 69 –
Leuze electronic
HRT 96 Laser light scanner with background suppression
Dimensioned drawing

100 … 5000mm

10 - 30 V
DC

! Laser scanner with large detection range for


universal application
! Phase measurement makes use possible
under extreme environmental conditions
A Indicator diode green
(brightness, light)
B Indicator diode yellow
! Three switching points can be set independ- C Receiver
ently of each other D Transmitter
! Analogue output, combined with switching E Optical axis
outputs F Device plug M12x1
! Switching behaviour independent of the G Countersinking for SK nut M5, 4.2 deep
direction of movement H Indicator diode red
I Indicator diode yellow
! Good black/white behaviour over the entire K Scanning range adjustment Q2
adjustment range L Scanning range adjustment Q3
M Scanning range adjustment Q1

Electrical connection
ISO
9001
We reserve the right to make changes • 96_d05e.fm

IP 69K
IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! M12 connectors (KD …)
! Ready-made cables (K-D …)

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 HRT 96 M/P-…-5000-… - 06
www.leuze.de

– 70 –
Leuze electronic
HRT 96
Specifications Tables
Optical data Switching no object
points reflection detected
Typ. scanning range limit (white 90%) 1) 5500mm
Scanning range 2) 100 … 5000mm/15m 3) LED off on
yellow Q 1
Adjustment range 500 … 5000mm/15m 3)
Light source laser (red light) LED off on
green Q 2
Wavelength 660nm
Laser warning notice see remarks LED off on
red Q 3
Timing
Switching frequency 20Hz
Response time 25ms
Delay before start-up ≤ 200ms Diagrams
Electrical data Analogue voltage for range = 15m
Operating voltage UB 10 … 30VDC (incl. residual ripple) 6
Residual ripple ≤ 15% of UB 5 A

Analogue voltage [V]


Bias current ≤ 40mA 4
Switching output PNP transistor
3
Function characteristics light or dark switching (adjustable)
Signal voltage high/low ≥ (UB -2V)/≤ 2V 2
Output current max. 100mA 1

Indicators 0
0 5 10 15
Sensor front
LED green ready Measurement range [m]
LED yellow reflection (Q1)
A Reflective tape
Sensor back see table
Mechanical data Metal housing Analogue voltage for range = 5m
Housing diecast zinc 5,0
Optics cover glass 4,5 A

Analogue voltage [V]


4,0 B
Weight 380g 3,5
Connection type M12 connector, 5-pin 3,0
2,5
Environmental data 2,0
1,5
Ambient temp. (operation/storage) 0°C … +40°C/-30°C … +70°C 1,0
Protective circuit 4) 1, 2, 3, 4 0,5
VDE safety class 5) II, all-insulated 0
0 1 2 3 4 5 6
Protection class IP 67, IP 69K 6)
Measurement range [m]
Standards applied IEC 60947-5-2
A white 90%
1) Typ. scanning range limit: max. attainable range without performance reserve
2) Scanning range: recommended range with performance reserve B grey 18%
3) Reference: reflective tape
4) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, 4=interference blanking
5) Rating voltage 250VAC Remarks
6) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,
acids and bases are not part of the test ! With the set scanning
range, a tolerance of the
upper scanning range limit
is possible depending on
the reflection properties of
the material surface.
! Resolution (at 90%): 10mm
! Light spot diameter
Order guide 30mm at distance of 5m
8mm at distance of 1m
HRT 96M/P-3360-5000-426

Selection table
HRT 96M/P-3370-5000-436

HRT 96M/P-3375-5000-436

! Switching points can be set


as required within the
adjustment range.
Part No. 500 39470

Part No. 500 40556

Part No. 500 40682

Order code " ! Scanning range/reflectivity:


Object/
diffuse
reflection
6 … 90% 0.1 … 5m
Equipment # (standard)
Reflective tape 0.1 … 15m
Housing metal ! ! ! (HG) (parameterisable
range
Light source red light ! ! ! adjustment)
Connection M12 connector ! ! !
Outputs 3 switching points 5m !
3 switching points 15m 3) !
dark switching !
analogue output and 2 !
switching points
switching points adjustable with ! ! !
potentiometer

HRT 96 M/P-…-5000-… - 06 0603

– 71 –
Leuze electronic
HRT 96 Laser light scanner
Dimensioned drawing

100 … 2500mm

10 - 30 V
DC

! Detection of reflective tape


! No influences from, e.g., metallic, mirroring,
or white surfaces
! Large detection range due to optimised ray
geometry A Indicator diode green
! Reliable detection under inclination, e.g. B Indicator diode yellow
during curved movement C Receiver
D Transmitter
! Phase measurement permits a high consist- E Optical axis
ency of the switching points F Device plug M12x1
! Teachable switching points for time- and G Countersinking for SK nut M5, 4.2 deep
space-saving installation H Indicator diodes yellow
I Scanning range adjustment Q2
K Scanning range adjustment Q1

Electrical connection
ISO
9001
We reserve the right to make changes • 96_d10e.fm

IP 69K
IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! M12 connectors (KD …)
! Ready-made cables (K-D …)

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 HRT 96M/P-336W.21-5000-426 - 03
www.leuze.de

– 72 –
Leuze electronic
HRT 96
Specifications Tables
Optical data Switching no object
points reflection detected
Typ. scanning range limit (reflective tape) 1) 2500mm/5000mm
Scanning range 2) 50 … 2500mm LED on off
yellow Q1
Adjustment range 2) 400 … 2500mm
Light source laser (red light) LED on off
yellow Q2
Wavelength 660nm
Laser warning notice see remarks
Timing
Switching frequency 10Hz
Response time 50ms
Delay before start-up ≤ 200ms Remarks
Electrical data ! With the set scanning
Operating voltage UB 10 … 30VDC (incl. residual ripple) range, a tolerance of the
Residual ripple ≤ 15% of UB upper scanning range limit
Bias current ≤ 40mA is possible depending on
Switching output PNP transistor the reflection properties of
Function characteristics light or dark switching (adjustable) the reflective tape.
Signal voltage high/low ≥ (UB -2V)/≤ 2V ! Resolution 50mm.
Output current max. 100mA
! Switching points can be set
Indicators as required within the
Sensor front adjustment range.
LED green ready
LED yellow reflection (Q1) ! Detection under inclination
Sensor back see table up to approx. 45°.
! Scanning range/reflectivity:
Mechanical data Metal housing
Housing diecast zinc Object/
Optics cover glass diffuse
Weight 380g reflection
Connection type M12 connector, 5-pin Reflective tape 0.1 … 2.5m/5m
(standard) (parameterisable
Environmental data range adjustment)
Ambient temp. (operation/storage) 0°C … +40°C/-30°C … +70°C
Protective circuit 3) 1, 2, 3, 4 ! Laser warning notice:
VDE safety class 4) II, all-insulated
Protection class IP 67, IP 69K 5)
Laser class 2 (acc. to EN 60825-1)
Standards applied IEC 60947-5-2
1) With reflective tape approx. 400 x 100mm2
2) Scanning range: recommended range with performance reserve, may be extended to 5000mm each via configuration
3) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, 4=interference blanking
4) Rating voltage 250VAC
5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids
and bases are not part of the test

Order guide Notices on


Teaching
HRT 96M/P-336W.21-5000-426

Selection table
! Teach Q1 first,
followed by Q2. For this pur-
pose: scanning
range Q2 ≤ scanning
Part No. 501 02286

Order code "


range Q1.
! Apply the scanning range
for the two switching points
Equipment # by pressing the respective
teach button.

Housing metal !
Light source red light (laser) !
Connection M12 connector !
Outputs 2 switching points !
dark switching !
analogue output 1 … 5V !
switching points settable via teach !
buttons

HRT 96M/P-336W.21-5000-426 - 03 0603

– 73 –
Leuze electronic
HRT 96 Laser light scanner with background suppression
Dimensioned drawing

80 … 2500mm

10 - 30 V
DC

! Laser scanner with large detection range for


universal application
! Phase measurement makes use possible
under extreme environmental conditions
A Indicator diode green
(brightness, light)
B Indicator diode yellow
! The switching points can be set/taught inde- C Receiver
pendently of each other D Transmitter
! Analogue output, combined with switching E Optical axis
outputs F Device plug M12x1
! Switching behaviour independent of the G Countersinking for SK nut M5, 4.2 deep
direction of movement H Indicator diode red
I Indicator diode yellow
! Clearly visible light spot for exact alignment K Scanning range adjustment Q2
! Optimised for positioning tasks and reliable L Scanning range adjustment Q3
object detection M Scanning range adjustment Q1
(e.g. compartment occupancy monitoring)

Electrical connection
ISO
9001
We reserve the right to make changes • 96_d07e.fm

IP 69K
IEC 60947... IEC 60947... IP 67

Accessories:
(available separately • see page 76)
! Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
! M12 connectors (KD …)
! Ready-made cables (K-D …)

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 HRT 96 M/P-…-2500-… - 02
www.leuze.de

– 74 –
Leuze electronic
HRT 96
Specifications Tables
Optical data Switching no object
points reflection detected
Typ. scanning range limit (white 90%) 1) 2500mm
Scanning range 2) 80 … 2200mm LED off on
yellow Q 1
Adjustment range 300 … 2200mm
Light source laser (red light) LED off on
green Q 2
Wavelength 660nm
Laser warning notice see remarks LED off on
red Q 3
Timing
Switching frequency 40Hz
Response time 12.5ms
Delay before start-up ≤ 200ms Typ. operating ranges
1 100 2000 2500
Electrical data 2 100 1800 1900
Operating voltage UB 10 … 30VDC (incl. residual ripple)
Residual ripple ≤ 15% of UB 3 100 1500 1600
Bias current ≤ 40mA
Switching output PNP transistor 1 white 90%
Function characteristics light or dark switching (adjustable) 2 grey 18%
Signal voltage high/low ≥ (UB -2V)/≤ 2V 3 black 6%
Output current max. 100mA
Scanning range [mm]
Indicators Typ. scanning range limit [mm]
Sensor front
LED green ready
LED yellow reflection (Q1)
Sensor back see table
Mechanical data Metal housing
Housing diecast zinc
Optics cover glass
Weight 380g
Connection type M12 connector, 5-pin
Environmental data
Ambient temp. (operation/storage) 0°C … +40°C/-30°C … +70°C
Protective circuit 3) 1, 2, 3, 4
VDE safety class 4) II, all-insulated
Protection class IP 67, IP 69K 5)
Standards applied IEC 60947-5-2
1) Typ. scanning range limit: max. attainable range without performance reserve
2) Scanning range: recommended range with performance reserve
3) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, 4=interference blanking
4) Rating voltage 250VAC
5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, Remarks
acids and bases are not part of the test
! With the set scanning
range, a tolerance of the
upper scanning range limit
is possible depending on
the reflection properties of
the material surface.
! Resolution (at 90%): 50mm
! Light spot diameter
Order guide 8mm at distance of 5m
5mm at distance of 1m
HRT 96M/P-3360-2500-426

Selection table
! Switching points can be set
as required within the
adjustment range.
Part No. 501 04825

Order code " ! Scanning range/reflectivity:


Object/
diffuse
reflection
6 … 90% 0.1 … 2.2m
Equipment # (standard)

Housing metal !
Light source red light/laser !
Connection M12 connector !
Outputs 3 switching points 2.5m
2 switching points and analogue !
output
dark switching
light switching !
switching points adjustable/ !
teachable

HRT 96 M/P-…-2500-… - 02 0603

– 75 –
Accessories
Leuze electronic
96 Series Accessories
Reflectors Dimensioned drawings

! Reflectors and reflective tapes are ideally


suited for Leuze retro-reflective photoelec-
tric sensors. The performance data refer to
the use of Leuze reflectors and reflective
tapes. The range of retro-reflective photoe-
lectric sensors depends on the type and
size of the reflector.
! Adhesive and screw type versions permit
universal installation.
! Precise optical alignment is not required, as
the reflector may be slightly inclined relative
to the optical axis.
! For retro-reflective photoelectric sensors
with polarisation filters, only triad-type
reflectors made of plastic or reflective tape
No. 4 may be used.

Order codes:
Designation Part No.
TKS 100x100 500 22816
TKS 40x60 500 40820
We reserve the right to make changes•96_zu_e.fm

TKS 30x50 500 23525


TKS 20x40 500 81283
MTKS 20x20 500 40895
MTKS 20x30 500 40894
MTKS 50x50 500 36188
Reflective tape No. 4 500 38062
Reflective tape No. 4, length on request

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 96 Series Accessories - 08
www.leuze.de

– 76 –
Leuze electronic
96 Series

Dimensioned drawings Connectors, cables


KD 095-4 KD 095-4A

KD 095-5 KD 095-5A

For devices with M12 connectors, there are


connectors with ready-made cables in various
lengths and connectors with screw connection
available.
Protection class (DIN 40050)
plugged and screwed: IP 67
Important:
K-D M12W-4P-… With throughbeam photoelectric sensors, a
K-D M12W-5P-… K-D M12A-4P-…
connector is required both for the transmitter
K-D M12W-4P-…-DP-… K-D M12A-5P-…
and the receiver.

Remarks
LED circuit diagram
(K-D M12…-4P-…-DP-…):
K-D M12A-4P-…-DP-…

96 Series Accessories - 08 0603

– 77 –
Leuze electronic
96 Series Accessories
Connectors, cables Selection table
M12 connector, user-configurable

Connection Without cable, 4-pin


Screw KD 095-4 KD 095-4A
terminals Part No. 500 31324 Part No. 500 31323
Without cable, 5-pin
Screw KD 095-5 KD 095-5A
terminals Part No. 500 20502 Part No. 500 20501
M12 connection cable with connector, single-sided

Length PVC cable sheath, 4-pin


K-D M12W-4P-2m-PVC K-D M12A-4P-2m-PVC
2m
Part No. 501 04543 Part No. 501 04542
K-D M12W-4P-5m-PVC K-D M12A-4P-5m-PVC
5m
Part No. 501 04545 Part No. 501 04544
K-D M12W-4P-10m-PVC K-D M12A-4P-10m-PVC
10m
Part No. 501 04547 Part No. 501 04546
K-D M12A-4P-20m-PVC
20m –
Part No. 501 04753
Length PUR cable sheath, 4-pin
K-D M12W-4P-2m-PUR K-D M12A-4P-2m-PUR
2m Part No. 501 04562 Part No. 501 04561
K-D M12W-4P-5m-PUR K-D M12A-4P-5m-PUR
5m
Part No. 501 04564 Part No. 501 04563
K-D M12W-4P-10m-PUR K-D M12A-4P-10m-PUR
10m
Part No. 501 04566 Part No. 501 04565
M12 connection cable with connector, single-sided,
with 2 integrated LEDs in transparent connector

Length PUR cable sheath, 4-pin


K-D M12W-4P-2m-DP-PUR K-D M12A-4P-2m-DP-PUR
2m
Part No. 501 04549 Part No. 501 04548
K-D M12W-4P-5m-DP-PUR K-D M12A-4P-5m-DP-PUR
5m
Part No. 501 04551 Part No. 501 04550
K-D M12W-4P-10m-DP-PUR K-D M12A-4P-10m-DP-PUR
10m
Part No. 501 04553 Part No. 501 04552
We reserve the right to make changes•96_zu_e.fm

M12 connection cable with connector, single-sided

Length PVC cable sheath, 5-pin


K-D M12W-5P-2m-PVC K-D M12A-5P-2m-PVC
2m
Part No. 501 04556 Part No. 501 04555
K-D M12W-5P-5m-PVC K-D M12A-5P-5m-PVC
5m
Part No. 501 04558 Part No. 501 04557
K-D M12W-5P-10m-PVC K-D M12A-5P-10m-PVC
10m
Part No. 501 04560 Part No. 501 04559
Length PUR cable sheath, 5-pin
K-D M12W-5P-2m-PUR K-D M12A-5P-2m-PUR
2m
Part No. 501 04568 Part No. 501 04567
K-D M12W-5P-5m-PUR K-D M12A-5P-5m-PUR
5m
Part No. 501 04762 Part No. 501 04569

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730
www.leuze.de

– 78 –
Leuze electronic
96 Series
Dimensioned drawings Mounting systems
BT 96 BT 96.1 Mounting brackets:
BT 96…

BT 96.4
Designation Part No.
BT 96 500 25570
BT 96.1 500 80614
BT 96.4 500 32319

Mounting systems:
UMS 96 BT 450.1-96 UMS 96
A
A

BT 450.1-96
A Sensor

UMS 96-82

UMS 96-82

Designation Part No.


UMS 96 500 26204
BT 450.1-96 500 82084
UMS 96-82 500 27191

ARH 96 Alignment aid:


ARH 96

Designation Part No.


ARH 96 500 80502

96 Series Accessories - 08 0603

– 79 –
Leuze electronic

Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730
www.leuze.de

– 80 –
Leuze electronic
P.O. Box 11 - n/Teck
T
021/ 57
Fax +49(0)7021/ 573-199

A qualified
ifi partner in
i the fi
field of...
f
...detection
● Standard sensors in cubic design ● Contrast, colour, luminescence scanners
● Cylindrical sensors ● Fibre optic amplifiers
● Measuring sensors ● Double sheet monitoring/splice detection
● Forked photoelectric sensors ● Accessories

...identification
● Bar code readers ● Bar code positioning systems
● Data matrix code readers ● Optical data transmission systems
● Hand-held readers ● Laser distance measuring devices
● RF identification systems ● Industrial machine vision

...protection
● Safety light curtains ● Safety relays and interfaces
● Multiple light beam safety devices ● Sensor accessories and signal devices
● Safety laser scanners ● Measuring light curtains
● Safety interlocks ● Service for all aspects of machine safety

For quick, simple sales and service information go to...

GB 191/01 – 03/06 Part No. 501 04 216

...www.leuze.de

You might also like