Design for Building movement Joint

Vertical Movement Typical L=4000 (height)


Item Building movement refer to Require as Specification Remark / Standard CWCT TN56
1 Thermal movement appendix B 4.00 Standrad formula = 0.000024 x different temperature about 40C x storey height
2 Column Shortening appendix B 2.00
3 Relative Beam Deflection
Long term deflection appendix B 2.00
Short term deflection appendix B 7.00
4 Installation tolerance appendix B 1.00
5 Out of Plane building drift appendix B 3.00 Refer to CWCT TN56, maximum out of plane building drift
-
As spec 19.00
PISA design 20mm > 16.5mm OK

Lateral Movement Typical L=1500 (width)


Item Building movement refer to For PISA design Remark
1 Thermal movement appendix B 1.44 Standrad formula = 0.000024 x different temperature 40C x panel width
2 Column Shortening appendix B 2.00
3 Relative Beam Deflection
Long term deflection appendix B 2.00
Short term deflection appendix B 3.20
4 Installation tolerance appendix B 1.00
As spec 9.64
PISA design 10mm > 9.64mm OK
Lateral Movement Vertical Movement