P×D t SCH .
t= SF =
[ 2×( ( S×E )+ ( P×Y ) ) ] tr
100
tr= [ 100−F ]
×( t +C )
WHERE :
t = PRESSURE DESIGN THICKNESS (mm)
tr = REQUIRED WALL THICKNESS (mm)
tSCH. = PIPE WALL THICKNESS PER SPESIFICATION
D = OUTSIDE DIAMETER OF PIPE (mm)
S = ALLOWABLE STRESS OF PIPE (kg/cm2) : 1,406 20,000 ( psig )
E = WELDING JOINT FACTOR : 1 1
P = DESIGN PRESSURE (kg/cm2) : 18.983 270 ( psig )
POP. = OPERATING PRESSURE (kg/cm2) : 1.055 15 ( psig )
T = DESIGN TEMPERATURE (oC) : 65.56 150 ( oF )
TOP. = OPERATING TEMPERATURE ( C) o
: 37.78 100 ( oF )
C = CORROSION ALLOWANCE (mm) : 1.588 0.0625 ( in )
Y = FACTOR (table) : 0.4 0.4
F = MANUFACTURER'S TOLERANCE (%) : 12.5 12.5 (%)
SF = SAFETY FACTOR
Page 3 of 4
52402-BDK-PIP-CS-010 Rev 0
08/28/2021
Y NPS D t tr SCH STD SF XS SF XXS SF SCH 30 SF SCH 40 SF SCH 160 SF
(in) (mm) (mm) (mm) NO (mm) (mm) (mm) (mm) (mm) (mm)
0.4 0.5 21.34 0.14 1.98 2.7 1.4 3.7 1.9 7.4 3.7 - - 2.7 1.4 4.7 2.4
0.4 0.75 26.67 0.18 2.02 2.8 1.4 3.9 1.9 7.8 3.9 - - 2.8 1.4 5.5 2.7
0.4 1 33.40 0.22 2.07 3.3 1.6 4.5 2.2 9.0 4.3 - - 3.4 1.6 6.3 3.0
0.4 1.5 48.26 0.32 2.19 3.6 1.6 5.0 2.3 10.1 4.6 - - 3.6 1.6 7.1 3.2
0.4 2 60.33 0.41 2.28 3.9 1.7 5.5 2.4 11.0 4.8 - - 3.9 1.7 8.7 3.8
0.4 3 88.90 0.60 2.50 5.4 2.2 7.6 3.0 15.2 6.1 - - 5.4 2.2 11.1 4.4
0.4 4 114.30 0.77 2.69 6.0 2.2 8.5 3.2 17.1 6.4 - - 6.0 2.2 13.4 5.0
0.4 6 168.30 1.13 3.11 7.1 2.3 10.9 3.5 21.9 7.1 - - 7.1 2.3 18.2 5.9
0.4 8 219.10 1.47 3.50 8.1 2.3 12.7 3.6 22.2 6.3 7.0 2.0 8.1 2.3 23.0 6.6
0.4 10 273.05 1.83 3.91 9.2 2.4 12.7 3.2 25.4 6.5 7.8 2.0 9.2 2.4 28.5 7.3
0.4 12 323.85 2.17 4.30 9.5 2.2 12.7 3.0 25.4 5.9 8.3 1.9 10.3 2.4 33.3 7.7
0.4 14 355.60 2.39 4.54 9.5 2.1 12.7 2.8 - - 9.5 2.1 11.1 2.4 35.7 7.9
0.4 16 406.40 2.73 4.93 9.5 1.9 12.7 2.6 - - 9.5 1.9 12.7 2.6 40.4 8.2
0.4 18 457.20 3.07 5.32 9.5 1.8 12.7 2.4 - - 11.1 2.1 14.2 2.7 45.2 8.5
0.4 20 508.00 3.41 5.71 9.5 1.7 12.7 2.2 - - 12.7 2.2 15.0 2.6 50.0 8.8
0.4 22 558.80 3.75 6.10 9.5 1.6 12.7 2.1 - - 12.7 2.1 - - 56.9 9.3
0.4 24 609.60 4.09 6.49 9.5 1.5 12.7 2.0 - - 14.2 2.2 17.4 2.7 59.5 9.2
0.4 26 660.40 4.43 6.88 9.5 1.4 12.7 1.8 - - 15.8 2.3 17.4 2.5 - -
0.4 28 711.20 4.78 7.27 9.5 1.3 12.7 1.7 - - 15.8 2.2 17.4 2.4 - -
0.4 30 762.00 5.12 7.66 9.5 1.2 12.7 1.7 - - 15.8 2.1 17.4 2.3 - -
0.4 32 812.80 5.46 8.05 9.5 1.2 12.7 1.6 - - 15.8 2.0 17.4 2.2 - -
0.4 34 863.60 5.80 8.44 9.5 1.1 12.7 1.5 - - 15.8 1.9 17.4 2.1 - -
0.4 36 914.40 6.14 8.83 9.5 1.1 12.7 1.4 - - 15.8 1.8 19.0 2.2 - -
0.4 38 965.20 6.48 9.22 9.5 1.0 12.7 1.4 - - - - - - - -
0.4 40 1016.00 6.82 9.61 9.5 1.0 12.7 1.3 - - - - - - - -
0.4 42 1066.80 7.16 10.00 9.5 0.9 12.7 1.3 - - - - - - - -
0.4 44 1117.60 7.50 10.39 9.5 0.9 12.7 1.2 - - - - - - - -
0.4 46 1168.40 7.85 10.78 9.5 0.9 12.7 1.2 - - - - - - - -
0.4 48 1219.20 8.19 11.17 9.5 0.9 12.7 1.1 - - - - - - - -
From the calculation above, the pipe selected for the application is:
30" SCH 20 (XS)
which has 12.7 mm thickness, well above the required thickness.
Therefore the selected pipe is ideal for its application. Page 4 of 4
52402-BDK-PIP-CS-010 Rev 0
08/28/2021
From the calculation above, the pipe selected for the application is:
30" SCH 20 (XS)
which has 12.7 mm thickness, well above the required thickness.