Greensboro, North Carolina Product Overview


Overhead Distribution Cutouts, Overhead Disconnect
Switches and Capacitor Fuses
greensboro overview.qxp 1/5/2005 11:16 AM Page 2

Overhead Distribution Cutouts Overhead Disconnect Switches


Product Description Application Options Product Description Application Options
• Distribution cutout for use on • Provides visible indication of • Silicone rubber insulator (110 - • Single insulator disconnect with • Single-phase disconnect on • Polymer concrete insulator
overhead distribution system to fuse operation and a visible 180 kV BIL) or polymer con- a double blade door and two 2- overhead distribution feeders (110 & 125 kV BIL)
provide overcurrent protection break sectionalizing point for crete insulator (110 & 125 kV hole extended NEMA pad termi- and in outdoor distribution sub-
• Optional mounting kit allows
maintenance personnel BIL) nals stations.
• Fuse tube interchangeable with the following mounting scenar-
S&C Type XS, Cooper Type L, • Can function as a loadbreak • Stainless steel seacoast design • 15 kV – 38 kV, 600 or 900 A • Can be mounted like a standard ios: single or double crossarm
and AB Chance Type C cutouts switch when used in conjunction continuous loads with a 40 kA cutout: underhung, mounted underhung, directly on a pole,
• Cutout/arrester combination
with a portable loadbreak tool momentary rating directly on a pole for use as a directly on a pole vertically,
• 15 kV – 38 kV, up to 16 kA
ICX • Emission Control Device (ECD) disconnect between overhead and crossarm vertically
and underground lines, or as a
• Outdoor loadbreak switch that • Provides overcurrent protection • Silicone rubber insulator (110 - visible disconnect for mainte-
can be used as a fused cutout for capacitor banks and gives 180 kV BIL) or polymer con- nance of line equipment
SID
for distribution systems visible indication that the equip- crete insulator (110 & 125 kV
ment is energized BIL) • Loadbreak single insulator dis- • Single-phase disconnect on • Polymer concrete insulator
• Loadbreak interruption is
accomplished by means of a • Used for switching the magnetiz- • Cutout/arrester combination connect with self-contained overhead distribution feeders (110 & 125 kV BIL)
self contained loadbreak arc ing currents of single and three- loadbreak capabilities, a double and in outdoor distribution sub-
• ECD • Optional mounting kit allows
chute which confines the arc phase transformer banks and to blade door, and two 2-hole stations
the following mounting scenar-
and provides a deionizing action switch capacitive currents asso- NEMA pad terminals
• Self-contained loadbreak ios: single or double crossarm
ciated with underground feeder • 15.5 kV – 15/27 kV, 600 A con- enables lineman to interrupt load underhung, directly on a pole,
• 15 kV – 27 kV, up to 16 kA
LBU cable at the riser pole tinuous and loadbreak current with a hookstick directly on a pole vertically,
and crossarm vertically
• Distribution cutout for overcur- • Provides visible indication of • Polymer concrete insulator • Can be mounted underhung like
rent protection on overhead dis- fuse operation and a visible (110 & 125 kV BIL) a standard cutout or mounted
tribution systems break sectionalizing point for directly on a pole used as a dis-
• Cutout/arrester combination connect between overhead and
maintenance personnel
• 15 kV – 38 kV, up to 20 kA underground lines
LSID
• Can function as a loadbreak
switch when used in conjunction • Double insulator single-phase • Hookstick operated switch used • Insulators available in 2.25”
with a portable loadbreak tool disconnect switch for sectionalizing or isolating bolt circle porcelain or epoxy
NCX
equipment on electrical distribu-
• Rated at 600 or 900 A, available • Bypass studs available for
• Enclosed cutouts in porcelain • Used in replacement applica- N/A tion systems up to 38 kV
in nominal ratings of 14.4 kV bypassing reclosers, voltage
housing tions in close spaces where
(110 BIL) or 25 kV (125 BIL) • Can be mounted vertical or regulators, capacitor banks, or
there are increased safety
• Designed for either dropout or underhung, or on a single or metering devices
needs
non-dropout operation DCD double crossarm

EU • For outdoor use only


• Single-phase bypass disconnect • Provides a means for bypassing • Insulators available in 2.25”
switch and disconnecting reclosers or bolt circle porcelain or epoxy
voltage regulators, allowing
• Rated at 600 or 900 A, available • Mounting options: back bracket
maintenance on equipment with-
in nominal ratings of 14.4 kV for vertical or underhung, 30-
out service interruption
(110 BIL) or 25 kV (125 BIL) degree pole-mount bracket, or
• Can be mounted in the following package of three switches pre-
configurations: vertical or under- mounted on crossarm
hung, pole-mounted, or single or
RBD double crossarm

• Single-phase, non-loadbreak, • Used for manual switching of N/A


inline tension disconnect switch de-energized or parallel circuits
with silicone insulator of overhead distribution lines
rated 15-38 kV
• Maximum voltage ratings: 15 kV
(150 BIL) or 27 kV (150 BIL) • Loadbreak hooks allow for oper-
ation with a portable loadbuster
• Continuous current rating of 600
tool
ITD or 900 A

-2- -3-
greensboro overview.qxp 1/5/2005 11:17 AM Page 4

Capacitor Fuses
Indoor
• 600 V Current Limiting
• Continuous amperes: 25, 50, 75, 100, 125, 150, 175, 200, 225
• Primary application is individual unit fusing of low voltage single and three phase capacitors in metal
CLN enclosed equipment

• 1.2-4.3 kV Current Limiting


• The 1200, 1800 and 3000 volt ratings are current limiting, indicating and non disconnecting
• The 2500 volt and 4.3/2.5 kV ratings are current limiting, non-indicating and non-disconnecting
• Primary application is individual unit fusing of low voltage single and three phase capacitors in metal
CLC enclosed equipment

• 5.5-15.5 kV Current Limiting & Expulsion


• Two part design:
- the high current section interrupts high 60Hz fault currents and/or high frequency discharge current
from parallel capacitors
- the low voltage sections consist of a standard NEMA type K fuse link mounted in a fiber tube
CIL

Outdoor
• 9.7-26.2 kV Expulsion
• Primary application is individual capacitor unit fusing in outdoor capacitor equipment
• Applications: in all ungrounded wye applications, in all grounded wye applications when the capacitor
CXP units are connected in two or more series group

• 2.8-23 kV Current Limiting & Expulsion


• Two part design:
- the high current section interrupts high 60Hz fault currents and/or high frequency discharge current
from parallel capacitors
COL - the low voltage sections consists of a standard NEMA type K fuse link mounted in a fiber tube

• 2.5-25 kV Current Limiting & Expulsion


• A very high energy capability individual capacitor fuse used in outdoor banks with many parallel
CLXP capacitor units

© Copyright 2004 ABB. All rights reserved.


1VAG0001-DB Rev. A October 2004
ABB Inc.
406 Banner Avenue
Greensboro, NC 27401
Tel: +1-252-827-3212
www.abb.com/mediumvoltage