SERVICE MANUAL
6F., NO. 32, Sec. 1,Chenggong Rd, Taipei, Taiwan 115, Website:www.cyberpowersystems.com TEL: 886-2-26518699 FAX:886-2-26516821
Copyright ©2005 CyberPower Systems, Inc. All rights reserved
1 / 18
Table of Contents
1. Product Feature ----------------------------------------------------------------- 03
5. Schematic ------------------------------------------------------------------------ 16
5.1 CHGR Parts ----------------------------------------------------------------- 16
5.2 COM & CPU Parts --------------------------------------------------------- 16
5.3 AVR Parts -------------------------------------------------------------------- 17
5.4 INVERTER Parts ----------------------------------------------------------- 18
6F., NO. 32, Sec. 1,Chenggong Rd, Taipei, Taiwan 115, Website:www.cyberpowersystems.com TEL: 886-2-26518699 FAX:886-2-26516821
Copyright ©2005 CyberPower Systems, Inc. All rights reserved
2 / 18
Product Features:
User-Replaceable batteries
Auto-Restart / Auto-Charge
2U Rack Space
6F., NO. 32, Sec. 1,Chenggong Rd, Taipei, Taiwan 115, Website:www.cyberpowersystems.com TEL: 886-2-26518699 FAX:886-2-26516821
Copyright ©2005 CyberPower Systems, Inc. All rights reserved
3 / 18
2.Components Location
PR1500E / PR2200E / PR3000E Front Panel (Fig2-1)
○ 1 ○○○ ○ ○ ○
2 3 4 5 6 7 ○8
PR1500E/2200E/3000E
No. Description Q’TY Remark
○ Power Switch
1 1
○2 Test Switch 1
○ Battery Level Indicators
3 4 25%,50%,75%,100%
○4 Load Level Indicators 4 25%,50%,75%,100%
○ Using Battery Indicator
5 1 Yellow LED
○6 AVR Indicator (Boost & Trim) 1 Green LED
○ Power On Indicator
7 1 Green LED
○8 Battery Cover 1
6F., NO. 32, Sec. 1,Chenggong Rd, Taipei, Taiwan 115, Website:www.cyberpowersystems.com TEL: 886-2-26518699 FAX:886-2-26516821
Copyright ©2005 CyberPower Systems, Inc. All rights reserved
4 / 18
PR1500E/2200E Rear Panel (Fig2-2)
○
1 ○○
2 3 ○
3 ○ 3 ○4 ○5 ○ ○
6 7 ○8
○ ○
1 2 ○
1 ○2 ○ ○ ○
1 2 7 ○4 ○ ○ 5 6 ○
8
6F., NO. 32, Sec. 1,Chenggong Rd, Taipei, Taiwan 115, Website:www.cyberpowersystems.com TEL: 886-2-26518699 FAX:886-2-26516821
Copyright ©2005 CyberPower Systems, Inc. All rights reserved
5 / 18
3.Principle Of Operation
3.1.System Functional Block Diagram
DC Fuse
AC Cap.
48V Batt.
DC Cap.
OUTPUT
Boost
Relay
Transfer
Relay
INPUT
AC Fuse
6F., NO. 32, Sec. 1,Chenggong Rd, Taipei, Taiwan 115, Website:www.cyberpowersystems.com TEL: 886-2-26518699 FAX:886-2-26516821
Copyright ©2005 CyberPower Systems, Inc. All rights reserved
7 / 18
3.4.UPS Buck Mode
When the voltage of AC utility power is higher than normal, Buck Relay will activate and
AVR transformer will buck the voltage down to normal mode (Buck Mode), at the same
time utility power keeps charging battery via AC/DC circuit (UPS Buck Mode).
U
PS Buck Mode
6F., NO. 32, Sec. 1,Chenggong Rd, Taipei, Taiwan 115, Website:www.cyberpowersystems.com TEL: 886-2-26518699 FAX:886-2-26516821
Copyright ©2005 CyberPower Systems, Inc. All rights reserved
8 / 18
4.Repair Procedure
4.1 Test Procedure
※For PR1500E/2200E
6F., NO. 32, Sec. 1,Chenggong Rd, Taipei, Taiwan 115, Website:www.cyberpowersystems.com TEL: 886-2-26518699 FAX:886-2-26516821
Copyright ©2005 CyberPower Systems, Inc. All rights reserved
9 / 18
※For PR3000E
6F., NO. 32, Sec. 1,Chenggong Rd, Taipei, Taiwan 115, Website:www.cyberpowersystems.com TEL: 886-2-26518699 FAX:886-2-26516821
Copyright ©2005 CyberPower Systems, Inc. All rights reserved
10 / 18
4.3 Repair Steps
Please follow the repair procedures step by step.
• Check the outlook of the unit to see if there is any damage on the surface.
4.3.1 Preparation
• Remove the cover.
• Measure the battery voltage by DC voltage meter, the normal voltage should be within the
range of 40V~54.0V
• Discharge the capacitor by connecting the resistor between the anode and cathode of
C19/C20/C82 (for PR3000E).
6F., NO. 32, Sec. 1,Chenggong Rd, Taipei, Taiwan 115, Website:www.cyberpowersystems.com TEL: 886-2-26518699 FAX:886-2-26516821
Copyright ©2005 CyberPower Systems, Inc. All rights reserved
11 / 18
4.3.2 Check the voltage of MOSFET and BJT of the Inverter circuit of PCB
※PR1500E/2200E
Part Measured Expected Reading Possible damaged component
reference location
Q10 S-G/S-D 0.45-0.65V Q10,D66
Q11 S-G/S-D 0.45-0.65V Q11,D16
Q12 S-G/S-D 0.45-0.65V Q12,D65
Q13 S-G/S-D 0.45-0.65V Q13,D24
Q14 S-G/S-D 0.45-0.65V Q14,D64
Q15 S-G/S-D 0.45-0.65V Q15,D67
Q18 S-G/S-D 0.45-0.65V Q18,D70
Q19 S-G/S-D 0.45-0.65V Q19,D73
Q20 S-G/S-D 0.45-0.65V Q20,D69
Q21 S-G/S-D 0.45-0.65V Q21,D72
Q22 S-G/S-D 0.45-0.65V Q22,D68
Q23 S-G/S-D 0.45-0.65V Q23,D71
Q8 B-E/B-C 0.45-0.65V Q8
Q9 B-E/B-C 0.45-0.65V Q9
Q26 B-E/B-C 0.45-0.65V Q26
Q27 B-E/B-C 0.45-0.65V Q27
※PR3000E
6F., NO. 32, Sec. 1,Chenggong Rd, Taipei, Taiwan 115, Website:www.cyberpowersystems.com TEL: 886-2-26518699 FAX:886-2-26516821
Copyright ©2005 CyberPower Systems, Inc. All rights reserved
12 / 18
Part reference Measured Expected Reading Possible damaged component
location
Q10 S-G/S-D 0.45-0.65V Q10,D66
Q11 S-G/S-D 0.45-0.65V Q11,D16
Q12 S-G/S-D 0.45-0.65V Q12,D65
Q13 S-G/S-D 0.45-0.65V Q13,D24
Q14 S-G/S-D 0.45-0.65V Q14,D64
Q15 S-G/S-D 0.45-0.65V Q15,D67
Q45 S-G/S-D 0.45-0.65V Q45,D32
Q46 S-G/S-D 0.45-0.65V Q46,D33
Q47 S-G/S-D 0.45-0.65V Q47,D39
Q48 S-G/S-D 0.45-0.65V Q48,D75
Q18 S-G/S-D 0.45-0.65V Q18,D70
Q19 S-G/S-D 0.45-0.65V Q19,D73
Q20 S-G/S-D 0.45-0.65V Q20,D69
Q21 S-G/S-D 0.45-0.65V Q21,D72
Q22 S-G/S-D 0.45-0.65V Q22,D68
Q23 S-G/S-D 0.45-0.65V Q23,D71
Q24 S-G/S-D 0.45-0.65V Q24,D5
Q25 S-G/S-D 0.45-0.65V Q25,D13
Q17 S-G/S-D 0.45-0.65V Q17,D11
Q44 S-G/S-D 0.45-0.65V Q44,D31
Q8 B-E/B-C 0.45-0.65V Q8
Q9 B-E/B-C 0.45-0.65V Q9
Q26 B-E/B-C 0.45-0.65V Q26
Q27 B-E/B-C 0.45-0.65V Q27
4.3.3 Check the resistance of RESISTOR of the Inverter circuit of the PCB
※PR1500E/2200E
Part reference Measured location Expected Reading Possible damaged component
R49,R50,R53,R54,R57, 39 Ohm R49,R50,R53,R54,R57,R58R70,
R58,R70,R73,R75,R76, R73,R75,R76,R80,R81
R80,R81
R47,R48, 22 Ohm R47,R48,R88,R89
R88,R89
※PR3000E
Part reference Measured location Expected Reading Possible damaged component
R49,R50,R53,R5,R57, 39 Ohm R49,R50,R53,R54,R57,R58,R70,
R58,R70,R73,R75,R76, R73,R75,R76,R80,R81,R85,R86,
R80,R81,R85,R86,R87, R87, R113, R74,R82,R83,R84
R113,R74,R82,R83,R84,
R47,R48, 22 Ohm R47,R48,R88,R89
R88,R89
6F., NO. 32, Sec. 1,Chenggong Rd, Taipei, Taiwan 115, Website:www.cyberpowersystems.com TEL: 886-2-26518699 FAX:886-2-26516821
Copyright ©2005 CyberPower Systems, Inc. All rights reserved
13 / 18
4.4 Turn on the unit with DC power supply
• Setup the instrument: adjust the output voltage of DC power supply to 54V with current limit
set at 5Adc.
• Connect the positive output of the DC power supply (Red wire) to the BAT(+)(Red wire) of
the PCB and the negative output (Black wire) to the BAT(-)(Black wire) of the PCB.
• Turn on the UPS then press the “Test” button on the front panel for at least 5 seconds.
• Check the reading of output current from the power supply, it should be between1~1.5A (or
1.7-2.1A for PR3000E).
• Check the output voltage of UPS. The reading should be within 225~240Vac.
• Check the waveform of UPS output, it should be sine wave.
If there is no output voltage, then the PCB needs to be checked by a higher level service
center.
• If the transfer fails, check if input circuit breaker is tripped or fuse is blown. When this
occurs, reset the circuit breaker or replace the fuse.
• If the UPS can not transfer to AC mode even with normal fuse and circuit breaker, then
check the waveform at C16.
O.K
N.G.
• If the waveform measured is N.G., please change C16 104Z (SMT package)
6F., NO. 32, Sec. 1,Chenggong Rd, Taipei, Taiwan 115, Website:www.cyberpowersystems.com TEL: 886-2-26518699 FAX:886-2-26516821
Copyright ©2005 CyberPower Systems, Inc. All rights reserved
14 / 18
4.7 Get Load Connected
• Connect load to the outlet of the UPS.
• Disconnect the AC input. The UPS should supply power to the load.
• Connect a computer to the UPS. Recover the AC input to UPS then disconnect the AC
utility power again.
• The computer should work properly without reboot OS when the UPS transfers between AC
mode and Battery mode.
• Confirm how many loads connected to the UPS while malfunction occurred
• When does the malfunction occur?
1. When the unit just first turned on.
2. When power failure occurs.
3. When the UPS return to AC mode.
4. When the UPS is in battery mode.
6F., NO. 32, Sec. 1,Chenggong Rd, Taipei, Taiwan 115, Website:www.cyberpowersystems.com TEL: 886-2-26518699 FAX:886-2-26516821
Copyright ©2005 CyberPower Systems, Inc. All rights reserved
15 / 18
5. Schematic
5.1 CHGR Parts
※PR1500E/PR220E/PR3000E
6F., NO. 32, Sec. 1,Chenggong Rd, Taipei, Taiwan 115, Website:www.cyberpowersystems.com TEL: 886-2-26518699 FAX:886-2-26516821
Copyright ©2005 CyberPower Systems, Inc. All rights reserved
16 / 18
5.3 AVR Parts
※PR1500E/PR2200E
※PR3000E
6F., NO. 32, Sec. 1,Chenggong Rd, Taipei, Taiwan 115, Website:www.cyberpowersystems.com TEL: 886-2-26518699 FAX:886-2-26516821
Copyright ©2005 CyberPower Systems, Inc. All rights reserved
17 / 18
5.4 INVERTER Parts
※PR1500E/PR2200E
※PR3000E
6F., NO. 32, Sec. 1,Chenggong Rd, Taipei, Taiwan 115, Website:www.cyberpowersystems.com TEL: 886-2-26518699 FAX:886-2-26516821
Copyright ©2005 CyberPower Systems, Inc. All rights reserved
18 / 18