Indian Standard
CODE OF PRACTICE FOR DESIGN OF
CROSS DRAINAGE WORKS
PART 2 SPECIFIC REQUIREMENTS
Section 2 Superpassages
(First Revision)
ICS 93.160
o DIS 2(X)O
(F.,. RnUiDII)
( Page 1, clause 4.1, line 3 ) - Substitute 'trought lor through'.
6
(WRD 13)
FOREWORD
This Indian Standard (Part 21Sec 2) (First Revision) was adopted by the Bureau of Indian Standards, after the
draft, finalized by the Cross DrainageWorksSectionalCommittee had been approved by the Water Resources
Division Council.
Cross drainage works are structures which are constructed to negotiate an aligned canier canal over, below or
at the same level of a drainage or another canier canal. With the knowledge now available, it is necessary to
formulate codes of practice for designs, constructions, inspectionand maintenanceof cross drainage works to
secure uniform standard.
This standard is published in two parts: Part 1 of this standard covers general requirements of the design of
cross-drainage works, Part 2 of this standards is being published in the five sections. The sections are listed
below:
Section 1 Aqueducts
Section 2 Superpassages
Section 3 Canal syphons
Section 4 Level crossings
Section S Syphon aqueducts
This section covers specific design requirements of superpassages.
There is no ISOIIEC standardon thissubject. Thisstandard has beenprepared basedon indigenous manufacturers'
data I practices prevalent in the field in India.
For the purpose of deciding whether a particularrequirementof this standard is complied with, the final value,
observed or calculated, expressing the result of a test or analysis, shall be rounded off in accordance with
IS 2 : 1960 'Rules for rounding off numericalvalues (revised)' . The numberof significantplaces retained in the
rounded off value should be the same as that of the specified value in this standard.
IS 7784 (part Z/See 2) : 2000
Indian Standard
CODE OF PRACTICE FOR DESIGN OF
CROSS DRAINAGE WORKS
PART 2 SPECIFIC REQUIREMENTS
Section 2 Superpassages
(First Revision)
2
IS 7784 (Part 2/Sec 1) : 2000
12 VIS AND DIS TRAINING WALLS provided so that they will not get dislodged during
the maximum flow.
Where the stream width has been restricted at the
crossing, a minimum splay of 2:) and ~: I on the u/s 15.1.2 The minimum length of the upstream protection
and dis sides may be provided respectively. shall be kept equal to D, the design depth of scour
below the floor level.
13 C.UT-OFFS AND SCOURS
15.2 Downstream Pervious Protection
13.1 Cut-off walls shall be provided at the end of the
solid floor on the u/s and dIs sides. 15.2.1 Rubble or blocks ofcement concrete of suitable
size shall be provided just beyond the dIs end of
13.2 The u/s and dIs cut-offs should generally be
impervious floor so that they will not get dislodged
provided to cater for scour of 1.25 R, and 1.5 R
during the maximum flood flow. The stones or blocks
respectively where R is the depth of scour, depending
shall be so arranged as to relieve the pressure at the
upon the nature of sub-soil.
ends of the impervious floor of the canal. Initial part
13.3 Scour depth should be calculated in accordance of the pervious protection may be provided with a
with IS 7784 (Part I). proper filter.
14 TOTAI.I FLOOR LENGTH N()TE - For beds of streams and drains which are not
easily susceptible to scour, the protection 111ay be minimized
14.1 The total length of the impervious floor of canal suitably.
from u/s to the dIs solid aprons (which includes
dissipation arrangements, if any) shall be fixed in 15.2.2 The minimum length of the dis protection shall
conjunction with the depth of cut-off to satisfy the be kept equal to 1.5 D. where D is the design depth of
requirement of exit gradient under the condition scour below the floor level.
when drain i~ at H.F.L and canal is empty, and the 15.3 Launching Apron
economy.
Beyond the pervious protection on the u/s and dis of
14.2 The impervious floor length of the drainage shall the work, bed may be protected with brickbats or loose
be such that the exit gradient at canal cutoff should be boulders or stones.
within permissible limits.
15.3.1 The quantity of loose stone protection required
14.3 The minimum thickness of solid floor shall be shall be determined on scour considerations.
kept as 30n nun.
15.3.2 The minimum thickness of the loose stone
IS PROTECTIVE WORKS protection shall be equal to the thickness of pitching
15.1 Upstream Pervious Protection on slopes.
IS.I.I Jusl beyond the end of impervious floors, rubble NOTE - The design of protection works shall comply the
or blocks of cement concrete of suitable size shall be provision of IS 7784 (Part I).
IS 7784 (Part 2/Sec 2) : 2000
11001
IRIDGE
CANAL
-------------------.-,:"I"':"':"...-.:"'~~~~~~n1~--
ENLARGED SECTION AT VY
TOP OF
INNER BEAM, TOP OF SIDE BEAM ROAD
BED:? m4:·F·~:~OTTOM~=
g-BITROUG~
SEC TION AT XX
r- v z
I .~m~~\
Fr ,iu.· ~ERY'OUS AND
lOOSE STONE
~ 141
~
•
~l '¥,~Tr-.;s=====l===~7J
. .... PROT ECTION UJ
~ ~ ~~
Ir---fr-\.....a.r-~--+----..... r ..j
U
lEvel o it: '
PORTION
SOLID' APRON
i f =!=
o
w
---:-- -
CD DRAINAGE
FLOW
---+-"-~~"·+I·I....~-M--I"""
u
~
m
~
01
BRICK
PITCHING ---..~
\~
LEVEL
PORTION ~I
T 1 r
i
I
r ~y"\L PERI/IOUS AN[ lOOSE STONE
PROTEe liON
FIG. I ATvPJCALLAYOvrOFASUPERPASSAGE
4
Bureau of Indian Standards
BIS is a statutory institution established under the Bureau of Indian Standards Act, 1986 to promote
harmonious development of the activities of standardization, marking and quality certification of goods
and attending to connected matters in the country.
Copyright
BIS has the copyright of all its publications. No part of these publications may be reproduced in any form
without the prior permission in writing of BIS. This does not preclude the free use, in the course of
implementing the standard, of necessary details, such as symbols and sizes, type or grade designations.
Enquiries relating to copyright be addressed to the Director (Publications), DIS.
Amendments are issued to standards as the need arises on the basis of comments. Standards are also
reviewed periodically; a standard along with amendments is reaffirmed when such review indicates that
no changes are needed; if the review indicates that changes are needed, it is taken up for revision. Users
of Indian Standards should ascertain that they are in possession of the latest amendments or edition by
referring to the latest issue of 'BIS Handbook' and 'Standards: Monthly Additions'.