Professional Documents
Culture Documents
Eaton Vane Pumps VMQ
Eaton Vane Pumps VMQ
Pump Characteristics pump instability could occur. Mounting Pad Accessory Pilot Diameter
If unloading pump at rates Drives
Minimum Speed Concentricity of the customer’s
over 5,171 bar/sec (75,000 A splined shaft is recommended female pilot diameter relative to
Minimum recommended start- psig/sec), make sure inlet
ing speed, under fluid conditions on applications where the pump the effective axis of the female
pressure does not fall below shaft is coupled directly into a drive must be within 0,10 mm
stated on page 7, is 0.83 bar (12 psi) absolute.
generally 600 r/min. However, transmission or gearbox. Spline (0.004 in.) total indicator reading.
the pump size, system charac- Drive Alignment drives should be lubricated. The clearance between the male
teristics and environmental con- Concentricity and angular align- The possibility of interference and female pilot diameters must
ditions can raise or lower this ment of shafts are important between the shaft and transmis- be +0,01 to +0,05 mm (+0.0005
speed. A lower speed can often to pump life. Misalignment can sion splines, due to tolerance to +0.0020 in.).
be achieved after the pump has induce heavy loads on bear- stack-up, can exist. Mounting Face
primed. ings, causing premature failure. To reduce this possibility, side The customer’s mounting face
If low starting or operating Flexible coupling halves must tooth spline fits should be used. to which the pump or motor is
speeds are required, consult be aligned according to the A side tooth fit and short length affixed must be square to the
your Eaton Hydraulics represen- coupling manufacturer’s recom- of engagement permits more axis of the female drive within
tative. mendations. flexibility and less tendency for 0,0381 mm per mm (0.0015
Rated Pressure Universal Joints side loading than does a major inch per inch).
diameter fit spline or long spline
Pumps should not be operated When using double universal Shafts
engagement. As a general rule,
at or near rated pressures at idle joint couplings, the shafts must Dimensions of keyed shaft
the minimum spline engagement
speeds for extended periods. be parallel and the yokes must receivers must be between
should not be less than 85%
Localized overheating and dam- be in line. The offset should +0,003 and +0,03 mm (+0.0001
of the spline pitch diameter to
age can result. be kept as low as possible. and +0.0010 in.) of the maxi-
ensure maximum shaft torque
Maximum allowable offset will, mum shaft diameter shown on
Never assume pumps in a rating.
of course, vary with application pages 68 and 70.
double, triple or thru-drive pump conditions. The pump shaft Mounting Dimensions
assembly can be simultaneously to universal joint diametral fit Requirements
loaded to rated pressure. Shaft should be close (major diameter
loading must be checked for Dimensional control require-
fit) with no looseness. ments of the customer’s mount-
excessive torque. Never load or
unload a VMQ pump at rates ing pad to which the pump or
greater than 10,342 bar/sec motor is affixed are as follows.
(150,000 psig/sec), because
Outlet
Inlet
Shaft
Vane
Outlet Outlet
Inlet
Inlet
Pump rotation
Figure 1 Figure 2
Cold Starts Drive Data Before starting the pump, fill CAUTION:
When operating with a fluid vis- Pumps are assembled for right with fluid through one of the Low Outlet Pressure.
cosity of over 54 cSt in industrial hand (clockwise) rotation or left ports. This is particularly impor-
tant if the pump is above the The minimum pres-
conditions, the outlet pressure hand (counterclockwise) rota-
should not exceed 50% of the tion. Rotation is viewed from fluid level of the reservoir. • sure differential
between the outlet
maximum rating for the VMQ the shaft end. Inlet and outlet When initially starting the and inlet must be 6.9
pump until the system has ports remain the same regard- pump, remove all trapped air bar (100 psig), otherwise, the
warmed up. When operating less of the direction of shaft from the system. This can be pump may fail prematurely.
with a fluid viscosity of over rotation. accomplished by loosening the
100cSt in mobile conditions, pump outlet fittings or connec- Once the pump is started,
Pump Drive
the speed and outlet pressure tions before starting the pump it should prime within a few
should not exceed 50% of the Direct coaxial drive is recom- or by using an air bleed valve. seconds. If the pump does
maximum ratings for the VMQ mended. Refer to pages 71-72 All inlet connections must be not prime, check to make sure
pump until the system has if imposing radial shaft loads are tight to prevent air leaks. An air that there are no restrictions
warmed up. required. bleed valve is available for this between the reservoir and the
Start-up Procedure purpose. inlet to the pump, and that there
Example for industrial are no air leaks in the inlet line
conditions: (Refer to catalog 690.)
Make sure the reservoir and and connections. Also check to
10 wt. oil at 90ºF (32ºC) will circuit are clean and free of CAUTION:
make sure that trapped air can
have a viscosity of 55 cSt. dirt/debris prior to filling with No Case Drain. escape at the pump outlet.
When the system fluid has a hydraulic fluid. • These pumps are After the pump is primed, tight-
viscosity lower than 55 cSt, it Fill the reservoir with filtered drained internally into en the loose outlet connections,
is considered warmed up. oil and fill to a level sufficient their inlet. System pressure at then operate for five to ten
Extreme caution must be used enough to prevent vortexing the pump inlet connection may minutes unloaded to remove all
when starting pumps with fluid at suction connection to pump not exceed 1,4 bar (20 psi). trapped air from the circuit.
viscosities greater than 860 cSt inlet. It is good practice to clean Also, the inlet hose should be
up the system by flushing and If the reservoir has a sight gage,
(4000 SUS). Care should be sized large enough to provide make sure the fluid is clear - not
exercised to warm up the entire filtering using an external slave a fluid velocity no greater than
pump. milky.
system, including remote cylin- 2.44 m/s (8 ft/sec)
ders and motors.
High Temperatures
Viscosities must not be less than
the minimum values shown in the
table below. Temperatures should
not exceed 99ºC (210ºF) because
the life expectancy of cartridge
kits and elastomers will decrease.
Proper fluid condition is essen- Eaton products, as any compo- Experience has shown, how-
tial for long and satisfactory life nents, will operate with apparent ever, that life of any hydraulic
of hydraulic components and satisfaction in fluids with higher components is shortened in
systems. Hydraulic fluid must cleanliness codes than those fluids with higher cleanliness
have the correct balance of described. Other manufacturers codes than those listed above.
cleanliness, materials and addi- will often recommend levels These codes have been proven
tives for protection against wear above those specified. to provide a long trouble-free
of components, elevated viscos- service life for the products
ity and inclusion of air. shown, regardless of the
Recommendations on contami- manufacturer.
nation control methods and the
selection of products to control
fluid condition are included in
publication 9132 or 561, “Guide
to Systemic Contamination
Control”. The book also includes
information on the concept of
“ProActive Maintenance”. The
following recommendations are
based on ISO cleanliness levels
at 2 µm, 5 µm and 15 µm.
25 20,4 (45)
35 34,0 (75)
45 54,4 (120)
25T 27,2 (60)
35T 45,4 (100)
45T 63,5 (140)
2525 36,3 (80)
3525 49,9 (110)
4525 72,6 (160)
4535 79,4 (175)
352525 79,4 (175)
453525 102,1 (225)
Conversion Factors
■ ˚C = 5 (˚F - 32)/9
* In German, Pferdestarke (PS)
In French, cheval vapeur (ch) or (CV)
Frame Displacement Pressure Rating Maximum Speed Outlet Flow at Input Power at
Size (Maximum) Rating at 0 bar 1800 r/min 1800 r/min
(0 psig) inlet 210 bar 210 bar
(3000 psi) (3000 psi)
Continuous Peak ■
cm3/r (in3/r) bar (psi) bar (psi) r/min l/min (USgpm) kW (hp)
25 10 (0.62) 293 (4250) 310 (4500) 1800 14,3 (3.8) 6,6 (8.9)
16 (0.98) 293 (4250) 310 (4500) 1800 24,9 (6.6) 10,4 (14.0)
20 (1.23) 293 (4250) 310 (4500) 1800 32,7 (8.6) 13,1 (17.6)
25 (1.58) 293 (4250) 310 (4500) 1800 42,7 (11.3) 16,8 (22.6)
32 (1.96) 293 (4250) 310 (4500) 1800 53,3 (14.1) 20,9 (28.1)
40 (2.44) 293 (4250) 310 (4500) 1800 61,6 (15.9) 25,8 (34.4)
45 (2.75) 293 (4250) 310 (4500) 1800 71,0 (18.3) 29,1 (38.8)
50 (3.05) 293 (4250) 310 (4500) 1800 80,0 (20.6) 32,2 (43.0)
63 (3.84) 293 (4250) 310 (4500) 1800 103,9 (26.8) 40,6 (54.1)
71 (4.33) 293 (4250) 310 (4500) 1800 118,7 (30.6) 45,8 (61.0)
80 (4.88) 293 (4250) 310 (4500) 1800 136,1 (35.1) 51,6 (68.8)
90 (5.49) 262 (3800) 276 (4000) 1800 153,9 (40.65) 71,9 (96.5)
35 90 (5.49) 262 (3800) 276 (4000) 1800 149,7 (38.6) 58,7 (78.3)
100 (6.10) 262 (3800) 276 (4000) 1800 168,1 (43.4) 65,2 (87.0)
112 (6.83) 262 (3800) 276 (4000) 1800 190,1 (49.1) 73,0 (97.4)
125 (7.63) 262 (3800) 276 (4000) 1800 214,3 (55.3) 81,6 (108.8)
135 (8.24) 262 (3800) 276 (4000) 1800 233,9 (60.4) 88,1 (117.5)
140 (8.47) 220 (3200) 241 (3500) 1800 240,0 (63.42) 92,8 (124.4)
158 (9.64) 220 (3200) 241 (3500) 1800 272,6 (72.02) 109,7 (147.1)
45 140 (8.54) 262 (3800) 276 (4000) 1800 232,0 (60.0) 92,5 (123.3)
160 (9.76) 262 (3800) 276 (4000) 1800 269,3 (69.5) 105,7 (141.0)
180 (10.98) 262 (3800) 276 (4000) 1800 306,2 (79.0) 118,9 (158.6)
195 (11.89) 262 (3800) 276 (4000) 1800 332,0 (86.0) 128,8 (171.7)
215 (13.12) 220 (3200) 241 (3500) 1800 362,6 (95.8) 139.7 (187.4)
240 (14.65) 68.9 (1000) 75.8 (1100) 1800 435.7* (115.1)* 55.9* (75)*
Frame Displacement Pressure Rating Maximum Speed Outlet Flow at Input Power at
Size (Maximum) Rating at 0 bar Maximum r/min, Maximum r/min,
(0 psig) inlet 210 bar 210 bar
(3000 psi) (3000 psi)
Continuous Peak ■
cm3/r (in3/r) bar (psi) bar (psi) r/min l/min (USgpm) kW (hp)
25 10 (0.62) 280 (4060) 310 (4500) 3000 21,1 (5.6) 11,1 (14.8)
16 (0.98) 280 (4060) 310 (4500) 3000 38,8 (10.3) 17,6 (23.4)
20 (1.23) 280 (4060) 310 (4500) 3000 51,1 (13.5) 22,0 (29.4)
25 (1.58) 280 (4060) 310 (4500) 3000 68,3 (18.0) 28,3 (37.7)
32 (1.96) 280 (4060) 310 (4500) 3000 88,4 (23.4) 35,1 (46.8)
40 (2.44) 280 (4060) 310 (4500) 2600 77,4 (20.4) 38,1 (50.1)
45 (2.75) 280 (4060) 310 (4500) 2600 90,6 (23.9) 42,9 (57.6)
50 (3.05) 280 (4060) 310 (4500) 2600 103,3 (27.3) 47,6 (63.5)
63 (3.84) 280 (4060) 310 (4500) 2600 137,0 (36.2) 59,9 (79.9)
71 (4.33) 280 (4060) 310 (4500) 2600 157,9 (41.7) 67,6 (90.1)
80 (4.88) 280 (4060) 310 (4500) 2600 182,3 (48.2) 77,3 (102.9)
90 (5.49) 248 (3600) 276 (4000) 2200 172,5 (48.57) 85,8 (115.0)
35 90 (5.49) 250 (3625) 276 (4000) 2400 180,2 (47.6) 79,1 (105.4)
100 (6.10) 250 (3625) 276 (4000) 2400 204,2 (53.9) 87,9 (117.2)
112 (6.83) 250 (3625) 276 (4000) 2400 232,9 (61.5) 98,4 (131.2)
125 (7.63) 250 (3625) 276 (4000) 2400 264,4 (69.8) 109,9 (146.5
135 (8.24) 250 (3625) 276 (4000) 2200 259,0 (68.4) 113,5 (144.8)
140 (8.47) 210 (3000) 220 (3200) 2200 275,1 (72.66) 112,9 (151.5)
158 (9.64) 210 (3000) 220 (3200) 2200 326,2 (86.18) 134,4 (180.2)
45 140 (8.54) 250 (3625) 276 (4000) 2200 268,2 (70.9) 113,5 (151.4)
160 (9.76) 250 (3625) 276 (4000) 2200 312,1 (82.5) 129,8 (173.0)
180 (10.98) 250 (3625) 276 (4000) 2200 356,1 (94.1) 146.0 (194.6)
195 (11.89) 250 (3625) 276 (4000) 2200 379,7 (100.3) 158,1 (210.8)
215 (13.12) 220 (3200) 241 (3500) 2200 425,5 (112.4) 171,5 (230)
Frame size 25
Outlet pressure (bar)
0 25 50 75 100 125 150 175 200 225 250 275
72
70
2600 r/min
68
2400 r/min
dB(A)
66
64 1800 r/min
1500 r/min
62
60
1200 r/min
58
0 500 1000 1500 2000 2500 3000 3500 4000
Outlet pressure (psi)
Frame size 35
Outlet pressure (bar)
0 25 50 75 100 125 150 175 200 225 250 275
74
72
70
2200 r/min
68
dB(A)
1800 r/min
66
1500 r/min
64
1200 r/min
62
1000 r/min
60
58
0 500 1000 1500 2000 2500 3000 3500 4000
Outlet pressure (psi)
Frame size 45
Outlet pressure (bar)
0 25 50 75 100 125 150 175 200 225 250 275
75
73
2200 r/min
71
69
1800 r/min
dB(A)
67
65
1500 r/min
63 1200 r/min
61
59 1000 r/min
0 500 1000 1500 2000 2500 3000 3500 4000
Outlet pressure (psi)
VMQ1 ** * *** * * ** ** * * * * * * 00 * 0 32
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
1234 Series Designation B – (All frame sizes) 13 14 Input Shaft Type* 17 Inlet Port Type
SAE C 2-bolt
VMQ1 – Vane Pump Single 01 – SAE J744 keyed A – SAE J518 4-bolt split flange
Series 127,00 (5.000) x 12,4
(0.49) pilot Frame size 25: B – ISO 6162 4-bolt split flange
25,40 (1.000)
5 6 Frame Size 17,6 (0.69) slots on
181,0 (7.13) bolt circle Frame size 35: 18 Outlet Port Type
25 – 10-90 cm3/r 31,75 (1.250) A – SAE J518 4-bolt flange
C – (Frame size 25 only)
(0.62-5.49 in3/r) Frame size 45: B – ISO 6162 4-bolt flange
ISO 3019/2 100A2HW 38,10 (1.500)
35 – 90-158 cm3/r 2-bolt
(5.49-9.64 in3/r) 02 – SAE J744 splined 19 Outlet Port Position
100,00 (3.937) x 9,2
45 – 140-240 cm3/r (0.36) pilot Frame size 25: B-B Viewed from cover end
(8.54-14.65 in3/r) Frame size 35: C of pump (Adapter end for
14,1 (0.56) slots on Frame size 45: C-C
140,0 (5.51) bolt circle thru-drive units)
7 Pump Type 03 – ISO 3019/2 keyed A – Opposite inlet port
D – (Frame sizes 35 & 45 only)
S – Single Frame size 25: B – 90° CCW to inlet port
ISO 3019/2 125A2HW 25,00 (0.984)
T – Thru-drive 2-bolt C – In-line with inlet port
(Options at model codes Frame size 35:
125,00 (4.921) x 9,2 D – 90° CW to inlet port
12 and 15 16 must be 32,00 (1.260)
(0.36) pilot
specified for thru-drive Frame size 45: 20 Shaft Seal
18,1 (0.71) slots on
units) 180,0 (7.09) bolt circle 40,00 (1.575) A – Single, primary
05 – SAE J744 keyed B – Double, secondary (spring
8 9 10 Displacement 12 Rear Mounting Flange
Frame size 25: side out) Recommended
Frame size 25 and Orientation 31,75 (1.250) for wet mount applications
010 – 10 cm 3/r (0.62 in 3/r) Viewed from cover end Frame size 35:
016 – 16 cm 3/r (0.98 in 3/r) of pump (Adapter end for 38,10 (1.500) 21 Seal Type
thru-drive units, model
020 – 20 cm 3/r (1.23 in 3/r Frame size 45: N – Buna N
code 7 = T) 44,45 (1.750)
025 – 25 cm 3/r (1.58 in 3/r) V – Viton
032 – 32 cm 3/r (1.96 in 3/r) 0 – None (non thru-drive) 06 – SAE J744 splined W – Buna N with Viton shaft
040 – 40 cm 3/r (2.44 in 3/r) SAE A Frame size 25: C seal(s)
045 – 45 cm 3/r (2.75 in 3/r) A – In-line with mounting Frame size 35: C-C
050 – 50 cm 3/r (3.05 in 3/r) flange (frame sizes Frame size 45: D 22 Shaft Rotation
063 – 63 cm 3/r (3.84 in 3/r) 25 & 45) 07 – ISO 3019/2 keyed Viewed from shaft end
B – 90° to mounting flange of pump
071 – 71 cm 3/r (4.33 in 3/r) Frame size 25: 32,00 (1.260)
(frame sizes 25 & 45) Frame size 35: 40,00 (1.575) L – Left hand (CCW)
080 – 80 cm 3/r (4.88 in 3/r)
090 – 90 cm 3/r (5.49 in 3/r) C – 45° CCW to mounting 09 – SAE J744 splined R – Right hand (CW)
flange (frame size 35)
Frame size 35 Frame size 25: B
D – 45° CW to mounting Frame size 45: C 23 24 Special Features
090 – 90 cm 3/r (5.49 in 3/r) flange (frame size 35) (Not available on 00 – None
100 – 100 cm 3/r (6.10 in 3/r) SAE B thru-drive units)
112 – 112 cm 3/r (6.83 in 3/r) 25 Paint
E – In-line with mounting
125 – 125 cm 3/r (7.63 in 3/r) flange (frame sizes 15 16 Output Shaft Coupling
0 – None
135 – 135 cm 3/r (8.24 in 3/r) 25, 35 & 45) Thru-drive units, model A – Blue
140 – 140 cm 3/r (8.54 in 3/r) F – 90° to mounting flange code 7 = T
158 – 158 cm 3/r (9.64 in 3/r) (frame sizes 25 & 45) 00 – None (non thru-drive) 26 Customer Identification
Frame size 45 G – 45° CCW to mounting 16 – SAE J744 16-4 0 – None
140 – 140 cm 3/r (8.54 in 3/r) flange (frame size 35) A-spline shaft
160 – 160 cm 3/r (9.76 in 3/r) H – 45° CW to mounting flange 22 – SAE J744 22-4 27 28 Design Code
180 – 180 cm 3/r (10.98 in 3/r) (frame size 35) B-spline shaft 32 – 32 design
195 – 195 cm 3/r (11.89 in 3/r) SAE C 25 – SAE J744 25-4 Installation dimensions
215 – 215 cm 3/r (13.12 in 3/r) J – In-line with mounting flange B-B-spline shaft remain unchanged for
240 – 240 cm 3/r ( 14.65 in 3/r) (frame sizes 35 & 45) 32 – SAE J744 32-4 design numbers 30 to 39
K – 90° to mounting flange C-spline shaft inclusive.
(frame size 35) (frame sizes 35 & 45 only)
11 Front Flange Mounting Style
L – 45° CCW to mounting
A – (Frame size 25 only) flange (frame size 45)
SAE B 2-bolt
M – 45° CW to mounting flange
101,60 (4.000) x 9,4 (frame size 45)
(0.37) pilot
14,4 (0.57) slots on
146,0 (5.75) bolt circle
* Verify shaft torque ratings meet or exceed input torque requirements (see pg. 74).
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35
1 2 3 4 Series Designation 020 – 20 cm 3/r (1.23 in 3/r) 02 – SAE J744 splined B – 45° CCW to inlet port
(not available with 2525)
VMQ2 – Vane Pump Double 025 – 25 cm 3/r (1.58 in 3/r) Frame size 25: B-B
C – 45° CW to inlet port
Series 032 – 32 cm 3/r (1.96 in 3/r) Frame size 35: C (not available with 2525)
040 – 40 cm 3/r (2.44 in 3/r) Frame size 45: C-C D – 135° CW to inlet port
5 6 Frame Size (front section) (not available with 2525)
045 – 45 cm 3/r (2.75 in 3/r) 03 – ISO 3019/2 keyed
25 – 10-90 cm3/r 050 – 50 cm 3/r (3.05 in 3/r) E – Opposite inlet port
(0.62-5.49 in3/r) Frame size 25: (2525 only)
063 – 63 cm 3/r (3.84 in 3/r) 25,00 (0.984)
35 – 90-158 cm3/r F – 90° CCW to inlet port
(5.49-9.64 in3/r) 071 – 71 cm 3/r (4.33 in 3/r) Frame size 35: (2525 only)
32,00 (1.260)
45 – 140-240 cm3/r 080 – 80 cm 3/r (4.88 in 3/r) G – In-line with inlet port
(8.54-14.65 in3/r) 090 – 90 cm 3/r (5.49 in 3/r) Frame size 45: (2525 only)
40,00 (1.575)
Frame size 35 H – 90° CW to inlet port
7 8 Frame Size (rear section) 05 – SAE J744 keyed (2525 only)
090 – 90 cm 3/r (5.49 in 3/r)
25 – 10-90 cm3/r Frame size 25:
(0.62-5.49 in3/r) 100 – 100 cm 3/r (6.10 in 3/r) 31,75 (1.250) 27 Shaft Seal
35 – 90-158 cm3/r 112 – 112 cm 3/r (6.83 in 3/r) Frame size 35: A – Single, primary
(5.49-9.64 in3/r) 125 – 125 cm 3/r (7.63 in 3/r) 38,10 (1.500) B – Double, secondary (spring
135 – 135 cm 3/r (8.24 in 3/r) Frame size 45: side out)
9 Pump Type 44,45 (1.750) Recommended for wet
140 – 140 cm 3/r (8.54 in 3/r) mount applications
S – Standard 06 – SAE J744 Splined
158 – 158 cm 3/r (9.64 in 3/r)
10 11 12 Displacement Frame size 25: C 28 Seal Type
(Front Section) 16 Front Flange Mounting Style Frame size 35: C-C N – Buna-N
Frame size 25 A – (Frame size 25 only) Frame size 45: D
SAE B 2-bolt V – Viton
010 – 10 cm 3/r (0.62 in 3/r) 07 – ISO 3019/2 Keyed W – Buna-N with Viton
101,60 (4.000) x 9,4
016 – 16 cm 3/r (0.98 in 3/r) (0.37) pilot Frame size 25: shaft seal(s)
020 – 20 cm 3/r (1.23 in 3/r 32,00 (1.260)
14,4 (0.57) slots on 29 Shaft Rotation
025 – 25 cm 3/r (1.58 in 3/r) 146,0 (5.75) bolt circle Frame size 35:
032 – 32 cm 3/r (1.96 in 3/r) 40,00 (1.575) Viewed from shaft end of pump
B – (All frame sizes)
040 – 40 cm 3/r (2.44 in 3/r) SAE C 2-bolt 09 – SAE J744 Spline L – Left Hand (CCW)
045 – 45 cm 3/r (2.75 in 3/r) 127,00 (5.000) x 12,4 Frame size 25:B R – Right Hand (CW)
050 – 50 cm 3/r (3.05 in 3/r) (0.49) pilot Frame size 45° C
30 31 Special Features
063 – 63 cm 3/r (3.84 in 3/r) 17,6 (0.69) slots on
181,0 (7.13) bolt circle 20 21 Output Shaft Coupling 00 – None
071 – 71 cm 3/r (4.33 in 3/r)
C – (Frame size 25 only) 00 – None (standard
080 – 80 cm 3/r (4.88 in 3/r) double pump) 32 Paint
ISO 3019/2 100A2HW
090 – 90 cm 3/r (5.49 in 3/r) 2-bolt O – None
22 Inlet Port Type
Frame size 35 100,00 (3.937) x 9,2 A – Blue
090 – 90 cm 3/r (5.49 in 3/r) (0.36) pilot A – SAE J518 4-split flange
B – ISO 6162 4-bolt flange 33 Customer Identification
100 – 100 cm 3/r (6.10 in 3/r) 14,1 (0.56) slots on
140,0 (5.51) bolt circle O – None
112 – 112 cm 3/r (6.83 in 3/r) 23 Front Outlet Port Type
125 – 125 cm 3/r (7.63 in 3/r) D – (Frame sizes 35 & 45 only) 34 35 Design Code
A – SAE J518 4-bolt flange
135 – 135 cm 3/r (8.24 in 3/r) ISO 3019/2 125A2HW 32 – 32 design
2-bolt B – ISO 6162 4-bolt flange
140 – 140 cm 3/r (8.54 in 3/r) Installation dimensions
125,00 (4.921) x 9,2 24 Rear Outlet Port Type remain unchanged for
158 – 158 cm 3/r (9.64 in 3/r) (0.36) pilot design numbers 30 to 39
Frame size 45 A – SAE J518 4-bolt flange inclusive.
18,1 (0.71) slots on
140 – 140 cm 3/r (8.54 in 3/r) 180,0 (7.09) bolt circle B – ISO 6162 4-bolt flange
160 – 160 cm 3/r (9.76 in 3/r) 25 Front Outlet Port Position
17 Adapter Flange
180 – 180 cm 3/r (10.98 in 3/r) Viewed from cover end of pump
0 – None (standard
195 – 195 cm 3/r (11.89 in 3/r) double pump) A – Opposite inlet port
215 – 215 cm 3/r (13.12 in 3/r) B – 90° CCW to inlet port
18 19 Input Shaft Type*
240 – 240 cm 3/r (14.65 in 3/r) C – In-Line with front
01 – SAE J744 keyed inlet port
13 14 15 Displacement
Frame size 25: D – 90° CW to inlet port
(Rear Section) 25,40 (1.000)
Frame size 25 Frame size 35: 26 Rear Outlet Port Position
010 – 10 cm 3/r (0.62 in 3/r) 31,75 (1.250)
Viewed from cover end of pump
016 – 16 cm 3/r (0.98 in 3/r) Frame size 45:
38,10 (1.500) A – 135° CCW to inlet port
(not available with 2525)
* Verify shaft torque ratings meet or exceed input torque requirements (see page 74).
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35
1 2 3 4 Series Designation
Frame size 35 05 – SAE J744 keyed 453525 units
VMQ3 – Vane pump triple series 090 – 90 cm 3/r (5.49 in 3/r) Frame size 35: E – Opposite inlet port
100 – 100 cm 3/r (6.10 in 3/r) 38,10 (1.500) F – 90° CCW to inlet port
5 6 Frame Size (Front Section) 112 – 112 cm 3/r (6.83 in 3/r) Frame size 45: G – In-line with inlet port
35 – 90-158 cm 3/r 125 – 125 cm 3/r (7.63 in 3/r) 44,45 (1.750) H – 90° CW to inlet port
(5.49-9.64 in 3/r)
(Compatible with 25 135 – 135 cm 3/r (8.24 in 3/r) 06 – SAE J744 splined
middle section frame size 140 – 140 cm 3/r (8.47 in 3/r) Frame size 35: C-C 27 Shaft Seal
below) A – Single, primary
158 – 158 cm 3/r (9.64 in 3/r) Frame size 45: D
45 – 140-240 cm 3/r B – Double, secondary (spring
(8.54-14.65 in 3/r) 07 – ISO 3019/2 keyed
17 18 19 Displacement side out) Recommended
(Compatible with 35 middle Frame size 35: for wet mount applications
(Rear Section)
section frame size below) 40,00 (1.575)
Frame size 25
28 Seal Type
7 8 Frame Size (Middle Section) 010 – 10 cm 3/r (0.62 in 3
/r) 23 Port Type
N – Buna N
25 – 10-90 cm 3/r 016 – 16 cm 3/r (0.98 in 3
/r) A – Inlet: SAE J518 4-bolt
(0.62-5.49 in3/r) flange V – Viton
020 – 20 cm 3/r (1.23 in 3
/r)
35 – 90-158 cm 3/r Front outlet: SAE J518 W – Buna N with Viton
(5.49-9.64 in 3/r) 025 – 25 cm 3/r (1.58 in 3
/r) shaft seal(s)
4-bolt flange
032 – 32 cm 3/r (1.96 in 3
/r)
9 10 Frame Size (Rear Section) Middle outlet: SAE J518 4- 29 Shaft Rotation
040 – 40 cm 3/r (2.44 in 3
/r) bolt flange
25 – 10-90 cm 3/r 045 – 45 cm 3/r (2.75 in 3
/r) Rear outlet: SAE J518 Viewed from shaft end of pump
(0.62-5.49 in3/r) 4-bolt flange L – Left hand (CCW)
050 – 50 cm 3/r (3.05 in 3
/r)
063 – 63 cm 3/r (3.84 in /r) B – Inlet: ISO 6162 4-bolt R – Right hand (CW)
11 12 13 Displacement
3
flange
(Front Section) 071 – 71 cm 3/r (4.33 in 3
/r)
Front outlet: ISO 6162 30 31 Special Features
Frame size 35 080 – 80 cm 3/r (4.88 in 3
/r) 4-bolt flange
00 – None
090 – 90 cm 3/r (5.49 in 3/r) 090 – 90 cm 3/r (5.49 in 3
/r) Middle outlet: ISO 6162
4-bolt flange
100 – 100 cm 3/r (6.10 in 3/r) 32 Paint
20 Front Flange Mounting Style Rear outlet: ISO 6162
112 – 112 cm 3/r (6.83 in 3/r) 4-bolt flange 0 – None
A – SAE C 2-bolt
125 – 125 cm 3/r (7.63 in 3/r) SAE J744 127-2 A – Blue
135 – 135 cm 3/r (8.24 in 3/r) 127,00 (5.000) x 12,4 24 Front Outlet Port Position
(0.49) pilot 33 Customer Identification
140 – 140 cm 3/r (8.54 in 3/r) Viewed from cover end of pump
158 – 158 cm 3/r (9.64 in 3/r) 17,6 (0.69) slots on 0 – None
A – Opposite inlet port
Frame size 45 181,0 (7.13) bolt circle
B – 90° CCW to inlet port 34 35 Design Code
140 – 140 cm 3/r (8.54 in 3/r) B – ISO 3019/2 125A2HW
2-bolt C – In-line with inlet port 32 – 32 design
160 – 160 cm 3/r (9.76 in 3/r) D – 90° CW to inlet port Installation dimensions
125,00 (4.921) x 9,2
180 – 180 cm 3/r (10.98 in 3/r) (0.36) pilot remain unchanged for
195 – 195 cm 3/r (11.89 in 3/r) 18,1 (0.71) slots on 25 Middle Outlet Port Position design numbers 31 to
180,0 (7.09) bolt circle 39 inclusive.
215 – 215 cm 3/r (13.12 in 3/r) Viewed from cover end of pump
240 – 240 cm 3/r (14.65 in 3/r) 21 22 Input Shaft Type* A – Opposite inlet port
01 – SAE J744 keyed B – 90° CCW to inlet port
14 15 16 Displacement
(Middle Section) Frame size 35: C – In-line with inlet port
31,75 (1.250) D – 90° CW to inlet port
Frame size 25
010 – 10 cm 3/r (0.62 in 3
/r) Frame size 45:
26 Rear Outlet Port Position
016 – 16 cm 3/r (0.98 in 3
/r) 38,10 (1.500)
02 – SAE J744 splined Viewed from cover end of pump
020 – 20 cm 3/r (1.23 in 3
/r
025 – 25 cm 3/r (1.58 in 3
/r) Frame size 35: C 352525 Units
032 – 32 cm 3/r (1.96 in 3
/r) Frame size 45: C-C A – 135° CCW to inlet port
040 – 40 cm 3/r (2.44 in 3
/r) 03 – ISO 3019/2 keyed B – 45° CCW to inlet port
045 – 45 cm 3/r (2.75 in 3
/r) Frame size 35: C – 45° CW to inlet port
050 – 50 cm 3/r (3.05 in 3
/r) D – 135° CW to inlet port
32,00 (1.260)
063 – 63 cm 3/r (3.84 in 3
/r)
Frame size 45:
071 – 71 cm 3/r (4.33 in 3
/r)
080 – 80 cm 3/r (4.88 in 3
/r) 40,00 (1.575)
090 – 90 cm 3/r (5.49 in 3
/r)
* Verify shaft torque ratings meet or exceed input torque requirements (see page 74).
30 8
25 bar (psi)
6
7 (100)
20 70 (1000)
140 (2000)
15 4 210 (3000)
293 (4250)
10
010 2
5
0 0
400 600 800 1000 1200 1400 1600 1800 2000
Speed (r/min)
15 4
3
10
2
5
1
0 0
400 600 800 1000 1200 1400 1600 1800 2000
Speed (r/min)
16
140 (2000)
210 (3000)
30 8 293 (4250)
6
20
020
4
10
2
0 0
400 600 800 1000 1200 1400 1600 1800 2000
Speed (r/min)
80 7 (100)
Flow (US gpm)
20 70 (1000)
140 (2000)
60 210 (3000)
15 293 (4250)
40 10
040
20 5
0 0
400 600 800 1000 1200 1400 1600 1800 2000
Speed (r/min)
80 7 (100)
20 70 (1000)
70 140 (2000)
210 (3000)
60 293 (4250)
15
40 10
30
20 5
10
0 0
400 600 800 1000 1200 1400 1600 1800 2000
Speed (r/min)
080 7 (100)
Flow (l/min)
25
70 (1000)
80 140 (2000)
20 210 (3000)
293 (4250)
60 15
050
40 10
20 5
0 0
400 600 800 1000 1200 1400 1600 1800 2000
Speed (r/min)
60 15
40 10
20 5
0 0
400 600 800 1000 1200 1400 1600 1800 2000
Speed (r/min)
95 25
76 20
57 15
38 10
19 5
100
25
80 20
60 15
40 10
20 5
0 0
600 900 1200 1500 1800
Speed (r/min)
120
30
100
80 20
60
40 10
20
0 0
600 900 1200 1500 1800
Speed (r/min)
120 30
100
80 20
60
40 10
20
0 0
600 900 1200 1500 1800
Speed (r/min)
40
Flow (l/min)
140
120 30
100
80 20
60
40 10
20
0 0
600 900 1200 1500 1800
Speed (r/min)
150 40
125
30
100
75 20
50
10
25
0 0
600 900 1200 1500 1800
Speed (r/min)
150 40
30
100
20
50
10
0
200 400 600 800 1000 1200 1400 1600 1800 2000
Speed (r/min)
50
175 45
150 40
35
125
30
100 25
20
500 700 900 1100 1300 1500 1700 1900
Speed (r/min)
150 40
125
30
100
75 20
50
10
25
0 0
600 1200 1800
Speed (r/min)
150 40
30
100
20
50
10
0 0
600 1200 1800
Speed (r/min)
300 80 360
70 90
250 80
300
Flow (l/min)
200 70
50 240
60
150 40 50
180
30 40
100
20 120 30
50 20
10
60
0 0 10
600 1200 1800 0 0
Speed (r/min) 600 1200 1800
Speed (r/min)
bar (psi)
7 (100)
70 (1000) bar (psi)
140 (2000) 6.9 (100)
210 (3000) 51.7 (750)
Frame size 45: 195 cm3/r 262 (3800) Frame size 45: 240 cm3/r
360 82.7 (1200)
90 450 120
80 110
300 400
100
70
240 350 90
Flow (US gpm)
Flow (l/min)
60
300 80
Flow (l/min)
50
100
80
Flow (US gpm)
60
40
20
20
5
15 4
3
10
2
5
1
0 0
0 500 1000 1500 2000 2500 3000 3500
Speed (r/min)
045
60 7 (100)
15 70 (1000)
140 (2000)
40 210 (3000)
10 280 (4060)
20 5
016
0 0
0 500 1000 1500 2000 2500 3000 3500
Speed (r/min)
140
35 7 (100)
70 (1000)
120 14 (2000)
30 0 (3000)
28 (4060)
100
25
80
20
050
60 7 (100)
15 70 (1000)
14
40 10 210 (3000)
28 (4060)
020
20 5
0 0
0 500 1000 1500 2000 2500 3000 3500
Speed (r/min)
180
45
7 (100)
160 70 (1000)
40
(2000)
140 210 (3000)
35
280 (4060)
120
30
Flow (l/min)
100
25 7 (100)
063
70 (1000)
80 20 (2000)
210 (3000)
60 15 280 (4060)
40 10
025
20 5
0 0
0 500 1000 1500 2000 2500 3000 3500
Speed (r/min)
120 30
100 7 (100)
071
80 7 (1000)
20 140
60 210 (3000)
40 280 (4060)
032 10
20
0 0
0 500 1000 1500 2000 2500 3000 3500
Speed (r/min)
080 30
90 7 (100)
20 7 (1000)
140 (2000)
60
210 (3000)
040 10 280 (4060)
30
0 0
0 500 1000 1500 2000 2500 3000 3500
Speed (r/min)
120
Flow (l/min)
30
90 25
20
60 15
30 10
5
0
500 700 900 1100 1300 1500 1700 1900 2100 2300
Speed (r/min)
240 7 (100)
60 70 (1000)
(2000)
200 0 (3000)
50 25 (3625)
160
120
30
80 20
40 10
0 0
0 500 1000 1500 2000 2500 3000
Speed (r/min)
240 7 (100)
60 70 (1000)
14 (2000)
200 210 (3000)
50
25 (3625)
160
40
Flow (US gpm)
Flow (l/min)
120
30
80 20
40 10
0 0
0 500 1000 1500 2000 2500 3000
Speed (r/min)
160
40
120
30
80 20
40 10
0 0
0 500 1000 1500 2000 2500 3000
Speed (r/min)
300 7 (100)
7 (1000)
70 140 (2000)
250 210 (3000)
60 250 (3625)
200
50
Flow (US gpm)
Flow (l/min)
150 40
30
100
20
50
10
0 0
0 500 1000 1500 2000 2500 3000
Speed (r/min)
50
150 40
30
100
20
50
10
0 0
0 500 1000 1500 2000 2500
Speed (r/min)
150 40
30
100
20
50 10
0
0 500 1000 1500 2000 2500
Speed (r/min)
65
Flow (US gpm)
200 55
45
150
35
100 25
15
500 700 900 1100 1300 1500 1700 1900 2100 2300
Speed (r/min)
200
50
160 40
120 30
80 20
40 10
0 0
0 500 1000 1500 2000 2500
Speed (r/min)
200 50
150 40
30
100
20
50
10
0 0
0 500 1000 1500 2000 2500
Speed (r/min)
250
60
200
150 40
100
20
50
0 0
0 500 1000 1500 2000 2500
Speed (r/min)
150 40
100
20
50
0 0
0 500 1000 1500 2000 2500
Speed (r/min)
300 80
Flow (l/min)
250
60
200
150 40
100
20
50
0 0
0 500 1000 1500 2000 2500
Speed (r/min)
8
10
7
210 (3000) 010
Power (hp)
6 8
Power (kW)
5
140 (2000) 010
6
4
3 4
70 (1000) 010
2
2
1
7 (100) 010
0 0
600 1200 1800
Speed (r/min)
45 60
293 (4250) 045
40
50
35
25
30
20 140 (2000) 045
50
40
50
35
210 (3000) 050
30 40
Power (kW)
Power (hp)
25 140 (2000) 050
30
20 293 (4250) 020
60 80
293 (4250) 063
70
50
60
210 (3000) 063
40
50
Power (kW)
Power (hp)
30
20 210 (3000) 025
70 (1000) 063
20
140 (2000) 025
10
10 70 (1000) 025
7 (100) 063
7 (100) 025
0 0
600 1200 1800
Speed (r/min)
Power (hp)
40
50
140 (2000) 071
30 40 293 (4250) 032
60 80
60
Power (hp)
40
293 (4250) 040
140 (2000) 080
30 40
210 (3000) 040
20 70 (1000) 080
20 140 (2000) 040
10 70 (1000) 040
7 (100) 080
0 0 7 (100) 040
600 1200 1800
Speed (r/min)
60
40 50 68.9 (1000) 090
30 40
34.5 (500) 090
30
20
20
10 10
0
500 700 900 1100 1300 1500 1700 1900
0 Speed (r/min)
90 120
80 105
262 (3800) 090
70
90
60 210 (3000) 090
75
Power (kW)
Power (hp)
50
60
140 (2000) 090
40
45
30
30 70 (1000) 090
20
10 15
7 (100) 090
0 0
600 1200 1800
Speed (r/min)
90 120
262 (3800) 100
80 105
70
90 210 (3000) 100
60
75
Power (kW)
Power (hp)
50
60 140 (2000) 100
40
45
30
70 (1000) 100
30
20
10 15
7 (100) 100
0 0
600 1200 1800
Speed (r/min)
100 135
90 262 (3800) 112
120
80 105
210 (3000) 112
70
90
60
Power (kW)
Power (hp)
75
50 140 (2000) 112
60
40
45
30 70 (1000) 112
20 30
10 15
7 (100) 112
0 0
600 1200 1800
Speed (r/min)
Power (hp)
60 80
140 (2000) 125
60
40
40 70 (1000) 125
20
20
7 (100) 125
0 0
600 1200 1800
Speed (r/min)
Power (hp)
60 80 140 (2000) 135
60
40
70 (1000) 135
40
20
20
7 (100) 135
0 0
600 1200 1800
Speed (r/min)
Power (hp)
140 (2000) 140
60 80
60
40
70 (1000) 140
40
20
20
7 (100) 140
0
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Speed (r/min)
60 80
60 68.9 (1000) 158
40
40 34.5 (500) 158
20
20
0
500 700 900 1100 1300 1500 1700 1900
Speed (r/min)
Power (hp)
140 (2000) 140
60 80
60
40
70 (1000) 140
40
20
20
7 (100) 140
0 0
600 1200 1800
Speed (r/min)
Power (hp)
80
100 140 (2000) 160
60 80
60
40 70 (1000) 160
40
20
20
7 (100) 160
0 0
600 1200 1800
Speed (r/min)
120
80 140 (2000) 180
80
70 (1000) 180
40
40
7 (100) 180
0 0
600 1200 1800
Speed (r/min)
Power(hp)
120
80
80
40
40
0 0
600 1200 1800
Speed (r/min)
7 (100) 215
Power(hp)
120
80
80
40
40
0 0
600 1200 1800
Speed (r/min)
Frame size 45: 240 cm3/r
100
135 bar (psi) code
90 82.7 (1200) 240
120
68.9 (1000 240
80
105 51.7 (750 240
70 34.4 (500 240
90
60 17.2 (250) 240
75 6.9 (100) 240
50
Power (hp)
Power (kw)
60
40
45
30
30
20
15
10
0 0
500 700 900 1100 1300 1500 1700 1900
Speed (r/min)
EATON Vickers VMQ Series Vane Pumps V-PUVN-TM001-E5 February 2009 41
Typical Input
Power - Mobile
21 280 (4060)
15
18
12
15 210 (3000)
Power (hp)
Power (kW)
9 12
140 (2000)
9
6
70 (1000)
6
3
3
7 (100)
0 0
0 500 1000 1500 2000 2500 3000 3500
Speed (r/min)
25 280 (4060)
30
20
25
210 (3000)
15 20
Power (kW)
Power (hp)
140 (2000)
15
10
10 70 (1000)
5
5
7 (100)
0 0
0 500 1000 1500 2000 2500 3000 3500
Speed (r/min)
35
25
30 210 (3000)
20
25
Power (kW)
Power (hp)
140 (2000)
15 20
15
10 70 (1000)
10
5
5
7 (100)
0 0
0 500 1000 1500 2000 2500 3000 3500
Speed (r/min)
40
280 (4060)
50
35
30 40
210 (3000)
25
30
Power (kW)
Power (hp)
20 140 (2000)
15 20
70 (1000)
10
10
5
7 (100)
0 0
0 500 1000 1500 2000 2500 3000 3500
Speed (r/min)
40
50
35 210 (3000)
30 40
Power (kW)
Power (hp)
25 140 (2000)
30
20
70 (1000)
15 20
10
10
5 7 (100)
0 0
0 500 1000 1500 2000 2500 3000 3500
Speed (r/min)
60 80
70 280 (4060)
50
60
40
50 210 (3000)
Power (kW)
Power (hp)
30 40
140 (2000)
30
20
20 70 (1000)
10
10
7 (100)
0 0
0 500 1000 1500 2000 2500 3000
Speed (r/min)
Power (hp)
30 40 140 (2000)
30
20
70 (1000)
20
10
10
7 (100)
0 0
0 500 1000 1500 2000 2500 3000
Speed (r/min)
70
50 210 (3000)
60
Power (kW)
40
Power (hp)
50
140 (2000)
30 40
30
20 70 (1000)
20
10
10
7 (100)
0 0
0 500 1000 1500 2000 2500 3000
Speed (r/min)
80 280 (4060)
100
70
60 80 210 (3000)
50
Power (kW)
Power (hp)
60
40 140 (2000)
30 40
70 (1000)
20
20
10
7 (100)
0 0
0 500 1000 1500 2000 2500 3000
Speed (r/min)
80
100
70 210 (3000)
60 80
Power (hp)
Power (kW)
50
60 140 (2000)
40
30 40
70 (1000)
20
20
10
7 (100)
0 0
0 500 1000 1500 2000 2500 3000
Speed (r/min)
100
Power (hp)
60 80
140 (2000)
60
40
40 70 (1000)
20
20
7 (100)
0 0
0 500 1000 1500 2000 2500 3000
Speed (r/min)
Power (hp)
137.9 (2000)
60 80
60 68.9 (1000)
40
40 34.5 (500)
20
20
0
500 700 900 1100 1300 1500 1700 1900 2100 2300
Speed (r/min)
Power (hp)
60
75 140 (2000)
50
60
40
45
30 70 (1000)
20 30
10 15
7 (100)
0 0
600 1200 1800 2400
Speed (r/min)
Power (hp)
60 80 140 (2000)
60
40
70 (1000)
40
20
20
7 (100)
0 0
600 1200 1800 2400
Speed (r/min)
Power (hp)
140 (2000)
60 80
60
40 70 (1000)
40
20
20
7 (100)
0 0
600 1200 1800 2400
Speed (r/min)
105 140
90 120
Power (kW)
Power (hp)
60 80
45 60 70 (1000)
30 40
15 20
7 (100)
0 0
0 500 1000 1500 2000 2500 3000
Speed (r/min)
140
100
120
Power (kW)
Power (hp)
80
100 140 (2000)
60 80
60
40 70 (1000)
40
20
20
7 (100)
0 0
0 500 1000 1500 2000 2500 3000
Speed (r/min)
Power (hp)
120
80 140 (2000)
100
60 80
60 70 (1000)
40
40
20
20
7 (100)
0
0 500 1000 1500 2000 2500
Speed (r/min)
100
Power (kW)
137.9 (2000)
120
80 100
60 80
68.9 (1000)
40 60
40 34.5 (500)
20 20
0
0 700 900 1100 1300 1500 1700 1900 2100 2300
Speed (r/min)
120 160
210 (3000)
140
100
120
Power (kW)
Power (hp)
80 140 (2000)
100
60 80
60 70 (1000)
40
40
20
20
7 (100)
0 0
0 500 1000 1500 2000 2500
Speed (r/min)
Power (hp)
100
120 140 (2000)
80
60 80
70 (1000)
40
40
20
7 (100)
0 0
0 500 1000 1500 2000 2500
Speed (r/min)
70 (1000)
100
120 7 (100)
Power (hp)
80
60 80
40
40
20
0 0
0 500 1000 1500 2000 2500
Speed (r/min)
140 (2000)
150 200
70 (1000)
Power (kW)
Power (hp)
90 120
60 80
30 40
0 0
0 500 1000 1500 2000 2500
Speed (r/min)
120 7 (100)
160
Power (hp)
Power (kW)
90 120
60 80
30 40
0 0
0 500 1000 1500 2000 2500
Speed (r/min)
Inlet port
(dimensions below)
39,6
(1.56)
133,5
"M" on pilot face if metric flange, (5.25)
174,0 Model Code "C" 184,8/182,4
(6.85) No stamp if SAE flange (7.23/7.18)
87,0 Model Code "A"
(3.43) (see Model Code 11)
82,5
(3.25)
151,1
B4 (5.95)
(2 places) øB1
Full rad.
B3 B3 B2
137,4
(5.41)
26,19 35,71
(1.031) (1.406)
13,09
17,86
(0.515)
(0.703)
ø25,4
52,37 (1.00 dia.) ø38,1
(2.062) 69,85 (1.50 dia.)
(2.750)
26,19
(1.031)
34,925
(1.375)
Outlet port Inlet port
Code A: SAE J518 4-bolt flange Code A: SAE J518 4-bolt flange
Code B: ISO 6162 4-bolt flange Code B: ISO 6162 4-bolt flange
Threads: Threads:
Code A: 3 /8"-16UNC-2B, 22,0 (0.87) min. depth Code A: 1 /2 "-13UNC-2B, 27,0 (1.06) min. depth
Code B: M10 x 1.5, 17,0 (0.67) min. depth Code B: M12 x 1.75, 19,5 (0.77) min. depth
Inlet port
(dimensions below)
"M" on pilot face if metric flange,
Model Code "D"
No stamp if SAE flange
Model Code "B" 36,7
(see Model Code 11) (1.44) 154,2
(6.07)
213,0 209,7/202,7
(8.39) (8.26/7.98)
106,50
(4.19)
96,5 93,0
(3.80) (3.66) Inlet
Outlet
181,2
øB1 (7.13)
Full rad.
B4
(2 places)
B3 B3 B2
169,4
(6.67)
30,18 42,88
(1.188) (1.688)
15,09 21,44
(0.594) (0.844)
ø31,8 ø50,8
58,72 (1.25 dia.) 77,77 (2.00 dia.)
(2.312) (3.062)
29,36
(1.156) 38,89
(1.531)
3rd angle
For shaft dimensions see projection
pages 68-70.
In-line port arrangement
22,6/21,8
illustrated. "M" is marked if metric port threads
(0.890/0.858)
No marking if inch port threads
For alternative port arrange-
ments see Model Code 19 Outlet port
(dimensions below)
214,4
øB1 (8.44)
Full rad. B4
(2 places)
196,8
B3 B3 (7.75)
B2
36,50 61.93
(1.437) (2.43)
18,25 30,96
(0.719) (1.219)
ø38,1 ø76,2
79,38 (1.50 dia.) (3.00 dia.)
106,38
(3.125)
(4.118)
39,69
(1.563) 53,19
(2.094)
øB1
82,5 (3.25)
Inlet and
Outlet
B4
(2 places)
Full rad.
B3 B3 B2
26,19 35,71
(1.031) (1.406)
13.09 17,86
(0.515) (0.703)
ø25,4
52,37 (1.00 dia.)
ø38,1
(2.062) 26,19 69,85 (1.50 dia.)
(1.031) (2.750)
34,93
(1.375)
53
AS-568-152 O-ring
248,8/246,4 (9.80/9.70)
to mounting flange face
Detail of SAE B flange
per Model Code 12 = E
(SAE B flange in line with L (distance to snap-ring), see table 2 x 1/2" - 13UNC- 2B thru
mounting flange.) S see table
Coupling options per 13,0
(0.512)
Model Code 15 16 and
details are given in
Coupling, see table
table below.
73,03
173,9 (2.875)
(6.85)
101,67/101,63 146,05
(4.003/4.001) (5.750)
ø119,4
(4.7 dia.)
87,0
AS-568-155 O-ring (3.42)
ø81
"M" on pilot face if metric flange,
Model Code "D"
No stamp if SAE flange
Model Code "B"
(see Model Code 11)
Rear Mount Pumps
For list of suitable fixed and variable
Outlet port Inlet port displacement Vickers™ pumps, see page 56.
213,0 For details of rear mount and coupling
(8.39) options, see pages 54 and 55.
106,5
(4.19)
96,5 93,0
(3.80) (3.66)
Outlet Inlet
B4
(2 places)
Full rad. B2
B3 B3 42,88
(1.688)
24,44
30,18
(0.844)
(1.188)
15,09
(0.594)
ø50,8
ø31,8 (2.00 dia.)
58,72 (1.25 dia.) 77,77
(2.312) (3.062)
38,89
(1.531)
29,36
(1.156)
ø81
116,0 105,0
(4.57) (4.13)
Outlet port Inlet port
B-B
B4
(2 places)
]
Full rad.
B3 B3 B2
61,93
30,96 (2.438)
36,50 (1.219)
(1.437)
18,25
(0.719)
ø76,2
79,38 ø38,1 106,38 (3.00 dia.)
(3.125) (1.50 dia.) (4.118)
53,19
39,69 (2.094)
(1.563)
172,6
(6.80)
82,61/82,57
(3.253/3.251)
AS-568-152 O-ring
130,6
(5.14)
65,3
45˚ (2.57)
ø101,67/101,63
(4.003/4.001 dia.)
ø119,4
(4.70 dia.)
173,9
(6.85)
87,0
AS-568-155 O-ring (3.42)
45˚
ø127,07/127,03
(5.003/5.001 dia.)
106,6
(4.20)
AS-568-159 O-ring
213,1
(8.39)
45˚
S L
Coupling Code Description Shaft Extension 35T 45T
16 For pump shaft of SAE “A” size with 30˚ involute 32,8/31,2 (1.29/1.23) 33,3 (1.31) min. 34,2 (1.35) min.
splined shaft (per SAE std J744 JUL88)
9T 16/32 DP (per ANSI B92.1a 1976)
22 For pump shaft of SAE “B” size with 30˚ involute 41,8/40,2 (1.64/1.58) 42,3 (1.67) min. 43,2 (1.70) min.
splined shaft (per SAE std J744 JUL88)
13T 16/32 DP (per ANSI B92.1a 1976)
25 For pump shaft of SAE “B-B” size with 30˚ 46,8/45,2 (1.84/1.78) 47,4 (1.87) min. 48,3 (1.90) min.
involute splined shaft (per SAE std J744 JUL88)
15T 16/32 DP (per ANSI B92.1a 1976)
32 For pump shaft of SAE “C” size with 30˚ 56,8/55,2 (2.23/2.17) 58,5 (2.30) min. 58,8 (2.31) min.
involute splined shaft (per SAE std J744 JUL88)
14T 12/24 DP (per ANSI B92.1a 1976)
25VMQT V10 11
V20 62
PVB5/6 piston pump S124
PVM018/020 03
V2010/2020 double pump 11
20V(Q) 151
25V(Q) 167
2520V(Q) double pump 167
PVB10/15 piston pump S124
PVM018, 020, 045, 050, 057 07
VMQ125 09
35VMQT V10 11
V20 62
PVB5/6 piston pump S124
PVM018/020 03
V2010/2020 double pump 11
20V(Q) 151
25V(Q) 11
2520V(Q) double pump 11
PVB10/15 piston pump S124
VMQ125 09
35V(Q) 11
35**V(Q) double pump 11
45V(Q) 11
45**V(Q) double pump 11
PVM057, 063, 131, 141 11
VMQ135 02
45VMQT V10 11
V20 62
PVB5/6 piston pump S124
PVM018/020 03
V2010/2020 double pump 11
20V(Q) 151
25V(Q) 11
2520V(Q) double pump 11
PVB10/15 piston pump S124
VMQ125 09
VMQ22525 double pump 02
35V(Q) 11
35**V(Q) double pump 11
45V(Q) 11
45**V(Q) double pump 11
PVM057, 063, 131, 141 11
VMQ135 02
VMQ145 09
VMQ23525 double pump 02
VMQ245** double pump 09
3rd angle
For shaft dimensions projection
see pages 68-70.
The inlet/outlet configuration 324,6/317,6
of the illustration is: (12.78/12.50) 294,2
(11.60) "M" is marked if metric flange
Model code 25 = C No marking if SAE flange
167,4
Model code 26 = B (6.59)
39,6
(1.56)
M
136,1
ø81
(5.36)
"M" on pilot face if metric flange,
Model Code "C"
No stamp if SAE flange
Model Code "A"
(see Model Code 16) Port dimensions below
174,0
(6.85) 15,4/14,6
(0.607/0.575) A
87,0
(3.43)
90,0 82,5
(3.54) (3.25) 82,5 (3.25)
M Inlet Outlet Outlet
port port port
158,1
B4 (6.22)
(2 places) Full rad.
B3 B3 A
61,93
30,96 (2.438)
26,19
(1.219) (1.031)
13,09
(0.515)
ø76,2 ø25,4
(3.00 dia.) 52,37 (1.00 dia.)
106,38
(2.062)
(4.188)
26,19
(1.031)
53,19
(2.094) Inlet port Front and rear outlet ports Rear view "A-A"
Code A: SAE J518 4-bolt flange Code A: SAE J518 4-bolt flange
Code B: ISO 6162 4-bolt flange Code B: ISO 6162 4-bolt flange
Threads: Threads:
Code A: 5/8"-11UNC-2B, 30,2 (1.19) min. depth Code A: 3/8 "-16UNC-2B, 22,0 (0.87) min. depth
Code B: M16 x 2,0, 28,5 (1.12) min. depth Code B: M10 x 1,5, 17,0 (0.67) min. depth
3rd angle
For shaft dimensions projection
see pages 68-70.
342,5
The inlet/outlet configuration (14.65) max. 312,7 "M" is marked if metric flange
of the illustration is:
(12.31) No marking if SAE flange
Model code 25 = C 183,1
36,7 (7.21) 172,8
Model code 26 = B (1.44) (6.80)
17,7/16,7 45˚
(0.7/0.66)
82,5
(3.25)
1
ø81 172,8
(6.80)
A
B4
Full rad. (2 places)
B3 B3
B2 26,19
61,93
30,18 (2.438) (1.031)
(1.188) 30,96
15,09 (1,219) 13,09
(0.594) (0.515) ø25.4
ø31,8 (1.00 dia.)
(1.25 dia.) ø76.2
58,72 (3.00 dia.) 52.37
(2.312) (2.062)
106,38
(4.188)
29,36 26,19
(1.031) (1.031)
53,19
(2.094)
Front outlet port Inlet port Rear outlet port (view "A-A")
Code A: SAE J518 4-bolt flange Code A: SAE J518 4-bolt flange Code A: SAE J518 4-bolt flange
Code B: ISO 6162 4-bolt flange Code B: ISO 6162 4-bolt flange Code B: ISO 6162 4-bolt flange
Threads: Threads: Threads:
Code A: 7/16 "-14UNC-2B, 28,4 (1.12) min. depth Code A: 5 /8 "-11UNC-2B, 30,2 (1.19) min. depth Code A: 3 /8 "-16UNC-2B, 22,0 (0.87) min. depth
Code B: M10 x 1,5, 17,0 (0.67) min. depth Code B: M16 x 2,0, 25,4 (1.00) min. depth Code B: M10 x 1,5, 17,0 (0.67) min. depth
ø81
213,0
(8.39) 82,5
106,5 A
(4.19) (3.25)
116,0 (4.57)
113,0 (4.45) A 45˚
Outlet
Inlet
port
port
172,8
B4 (6.80)
Full rad. (2 places)
B2 172,8
B3 B3
(6.80)
36.50 26,19
69,85 (1.031)
(1.437) (2.750)
18,25 34,93 13,09
(0.719) (1.375) (0.515)
ø25,4
ø38,1 ø88,9
79,38 (1.00 dia.)
(1.50 dia.) 120,65 (3.50 dia.) 52,37
(3.125) (2.062)
(4.750)
39,69 26,19
(1.563) 60,33 (1.031)
(2.375)
Front outlet port Inlet port Rear outlet port (view "A-A")
Code A: SAE J518 4-bolt flange Code A: SAE J518 4-bolt flange Code A: SAE J518 4-bolt flange
Code B: ISO 6162 4-bolt flange Code B: ISO 6162 4-bolt flange Code B: ISO 6162 4-bolt flange
Threads: Threads: Threads:
Code A: 5/8"-11UNC-2B, 35,0 (1.38) min. depth Code A: 5 /8 "-11UNC-2B, 33,0 (1.31) min. depth Code A: 3/8"-16UNC-2B, 22,0 (0.87) min. depth
Code B: M16 x 2,0, 25,5 (1.00) min. depth Code B: M16 x 2,0, 25,4 (1.00) min. depth Code B: M10 x 1,5, 17,0 (0.67) min. depth
ø81
213,0
(8.39) 106,5
(4.19) A
116,5 112,0
(4.57) (4.41)
Outlet port A
Inlet port 208,7
(8.22)
B4 45˚
Full rad. (2 places) 96,5
(3.80)
B2 208,7
B3 B3 (8.22)
39,69 29,36
(1.563) 65,09
(1.156)
(2.563)
Front outlet port Inlet port Rear outlet port (view "A-A")
Code A: SAE J518 4-bolt flange Code A: SAE J518 4-bolt flange Code A: SAE J518 4-bolt flange
Code B: ISO 6162 4-bolt flange Code B: ISO 6162 4-bolt flange Code B: ISO 6162 4-bolt flange
Threads: Threads: Threads:
Code A: 5 /8"-11UNC-2B, 35,0 (1.38) min. depth Code A: 5 /8 "-11UNC-2B, 30,2 (1.19) min. depth Code A: 5/8"-11UNC-2B, 28,4 (1.12) min. depth
Code B: M16 x 2,0, 25,5 (1.00) min. depth Code B: M16 x 2,0, 25,4 (1.00) min. depth Code B: M10 x 1,5, 17,0 (0.67) min. depth
ø81
B4
45˚
(2 places)
Full rad. 82,5
(3.25) 172,8
B3 B3 (6.80)
B2 77,77
30,18 (3.062)
26,19
(1.188) 38,89 (1.031)
(1.531)
15,09 13,09
(0.594) (0.515)
ø101,6
ø31,8 130,18 (4.00 dia.) ø25,4
(1.25 dia.) (5.125) (1.00 dia.)
58,72 52,37
(2.312) (2.062)
65,09
29,36 (2.563)
26,19
(1.156) (1.031)
Outlet port, front section Inlet port Outlet port, middle section and
outlet port, rear section (view "A - A")
Code A: SAE J518 4-bolt flange Code A: SAE J518 4-bolt flange
Code B: ISO 6162 4-bolt flange Code B: ISO 6162 4-bolt flange Code A: SAE J518 4-bolt flange
Threads: Threads: Code B: ISO 6162 4-bolt flange
Code A: 7/16 "-14UNC-2B, 28,4 (1.12) min. depth Code A: 5/8"-11UNC-2B, 30,2 (1.19) min. depth Threads:
Code B: M10 x 1,5, 17,0 (0.67) min. depth Code B: M16 x 2,0, 25,4 (1.00) min. depth Code A: 3/8"-16UNC-2B, 22,0 (0.87) min. depth
Code B: M10 x 1,5, 17,0 (0.67) min. depth
ø81
108,0 (4.25)
Inlet port
B4
(2 places) 68,1
(2.68)
B3 B3 136,1
B2 (5.36)
Full rad.
Outlet port, front section Inlet port Outlet port, middle section Outlet port, rear section
Code A: SAE J518 4-bolt flange Code A: SAE J518 4-bolt flange Code A: SAE J518 4-bolt flange Code A: SAE J518 4-bolt flange
Code B: ISO 6162 4-bolt flange Code B: ISO 6162 4-bolt flange Code B: ISO 6162 4-bolt flange Code B: ISO 6162 4-bolt flange
Threads: Threads: Threads: Threads:
Code A: 5/8"-11UNC-2B, 35,0 (1.38) min. depth Code A: 5/8"-11UNC-2B, 30,2 (1.19) min. depth Code A: 7/16 "-14UNC-2B, 28,4 (1.12) min. depth Code A: 3/8"-16UNC-2B, 22,0 (0.87 ) min. depth
Code B: M16 x 2,0, 25,4 (1.00) min. depth Code B: M16 x 2,0, 25,4 (1.00) min. depth Code B: M10 x 1,5, 17,0 (0.67) min. depth Code B: M10 x 1,5, 17,0 (0.67) min. depth
8,01/5.99
(0.316/0.236) E
D øC
25(T) 01 SAE J744 70,00 (2.756) 8,84/7,22 25,40/25,36 28,23/27,99 6,363 (0.2505)
(0.348/0.284) (1.000/0.998) (1.112/1.102) x 49,23 (1.938)
03 ISO 3019/2 42,00 (1.654) 11,04/9,42 25,013/24,911 27,97/27,73 7,982 (0.3142)
(0.435/0.371) (0.9848/0.9839) (1.102/1.092) x 18,00 (0.709)
05 SAE J744 76,00 (2.992) 8,84/7,22 31,75/31,71 35,33/35,09 7,950 (0.3130)
(0.348/0.284) (1.250/1.248) (1.391/1.381) x50,80 (2.000)
07 ISO 3019/2 58,00 (2.283) 11,04/9,42 32,027/32,003 34,99/34,75 9,982 (0.3930)
(0.435/0.371) (1.2609/1.2599) (1.378/1.368) x 34,00 (1.339)
35(T) 01 SAE J744 76,00 (2.992) 8,81/7,19 31,75/31,71 35,33/35,09 7,950 (0.3130)
(0.347/0.283) (1.250/1.248) (1.391/1.381) x 50,80 (2.000)
03 ISO 3019/2 58,00 (2.283) 11,01/9,39 32,027/32,003 34,99/34,75 9,982 (0.3930)
(0.434/0.370) (1.2609/1.2599) (1.378/1.368) x 34,00 (1.339)
05 SAE J744 83,00 (3.268) 8,81/7,19 38,10/38,06 42,40/42,16 9,538 (0.3755)
(0.347/0.283) (1.500/1.498) (1.665/1.659) x 57,15 (2.250)
07 ISO 3019/2 82,00 (3.228) 11,01/9,39 40,027/40,003 42,98/42,71 11,979 (0.4716)
(0.434/0.370) (1.5759/1.5749) (1.693/1.682) x 56,00 (2.205)
45(T) 01 SAE J744 83,00 (3.268) 8,82/7,20 38,09/38,05 42,40/42,16 9,538 (0.3755)
(0.347/0.283) (1.500/1.498) (1.669/1.659) x 57,15 (2.250)
03 ISO 3019/2 82,00 (3.228) 11,02/9,40 40,027/40,003 43,03/42,79 11,979 (0.4716)
(0.434/0.370) (1.5759/1.5749) (1.695/1.685) x 56,00 (2.205)
05 SAE J744 92,00 (3.622) 8,82/7,20 44,45/44,41 49,43/49,19 11,125 (0.4380)
(0.347/0.283) (1.750/1.748) (1.947/1.937) x 57,15 (2.250)
2525 01 SAE J744 70,00 (2.756) 8,84/7,22 25,40/25,36 28,23/27,99 6,350 (0.2500)
(0.348/0.284) (1.000/0.999) (1.112/1.102) x 49,23 (1.938)
03 ISO 3019/2 42,00 (1.654) 11,04/9,42 25,013/24,99 27,97/27,73 7,964 (0.3135)
(0.435/0.371) (0.9848/0.9838) (1.102/1.092) x 18,00 (0.709)
05 SAE J744 76,00 (2.992) 8,84/7,22 31,75/31,71 35,33/35,09 7,938 (0.3125)
(0.348/0.284) (1.250/1.248) (1.391/1.381) x 50,80 (2.000)
07 ISO 3019/2 58,00 (2.283) 11,04/9,42 32,027/32,003 34,99/34,75 9,964 (0.3923)
(0.435/0.371) (1.2609/1.2599) (1.378/1.368) x 34,00 (1.339)
3525 01 SAE J744 76,00 (2.992) 8,81/7,19 31,75/31,71 35,33/35,09 7,950 (0.3130)
(0.347/0.283) (1.250/1.248) (1.391/1.381) x 50,80 (2.000)
03 ISO 3019/2 58,00 (2.283) 11,01/9,39 32,027/32,003 34,99/34,75 9,982 (0.3930)
(0.434/0.370) (1.2609/1.2599) (1.378/1.368) x 34,00 (1.339)
05 SAE J744 83,00 (3.268) 8,81/7,19 38,10/38,06 42,40/42,16 9,538 (0.3755)
(0.347/0.283) (1.500/1.498) (1.669/1.659) x 57,15 (2.250)
07 ISO 3019/2 81,99 (3.228) 11,02/9,40 40,037/40,003 42,98/42,71 11,98 (0.472)
(0.434/0.370) (1.5759/1.5749) (1.693/1.682) x 56,00 (2.205)
øC
F
Note: Graphs based on B-10 life of 3000 hours
Frame size 25
500 lb 2000
N
400 1600
300 1200
Load F (N)
Load F (lb)
200 800
100 400
0 0
600 1000 1400 1800 2200 2600 3000
Speed (r/min)
500 2000
Load F (N)
Load F (lb)
400 1600
300 1200
200 800
100 400
0 0
600 800 1000 1200 1400 1600 1800 2000 2200
Speed (r/min)
400 2000
Load F (N)
Load F (lb)
300 1500
200 1000
100 500
0 0
600 1000 1400 1800 2200 2600
Speed (r/min)
600 3000
Load F (N)
Load F (lb)
400 2000
200 1000
0 0
600 800 1000 1200 1400 1600 1800 2000 2200
Speed (r/min)
External involute spline toler- Shaft No.of Pitch Major Form Minor Base
ance class 7 ANSI B921A-1976 Type Teeth Pitch Dia. Dia. Dia. Dia. (Max) Dia.
30˚ pressure angle, flat root, B 13 16/32 20,637 22,23/22,17 19,02 18,16 17,87
side fit. (0.8125) (0.875/0.873) (0.749) (0.715) (0.7036)
B-B 15 16/32 23,812 24,99/24,80 22,15 21,38 20,62
(0.9375) (0.984/0.978) (0.872) (0.840) (0.8119)
C 14 12/24 29,63 32,22/31,06 27,48 26,41 25,66
(1.1667) (1.229/1.223) (1.082) (1.040) (1.0104)
C-C 17 12/24 35,98 37,57/37,41 33,76 32,77 31,16
(1.4167) (1.479/1.473) (1.329) (1.290) (1.2269)
D 13 8/16 41,27 43,71/43,56 38,13 36,63 35,75
(1.6250) (1.721/1.715) (1.501) (1.442) (1.4073)
Table 1
Single, Double and Triple Pumps Shaft Torque Ratings
Table 2
Thru-Drive Pumps Shaft Torque Ratings
500
Pressure (bar)
Note
To realize the high input (Eaton ships keyed shafts Spline shaft ends (nos. 02, 06
torque levels for keyed shafts with the corners of the key and 09) must be lubricated by
(nos. 01, 03, 05 and 07), the already chamfered.) Also, gearbox lubricant or anti-sei-
corners of the key must be the key must be installed in zure grease to prevent spline
chamfered 0,76 to 1,02 mm the keyway 8,01/5,99 mm wear and fretting.
(0.030 to 0.040 in) x 45° to (0.316/0.236 in) back from the
clear the radii in the keyway. end of the shaft as shown on
page 68.
Minimum Recommended Maximum Max. Continuous Max. Transient Max. Steady Max. Transient
Inlet Pressure Operating Inlet Positive Inlet Operating Operating State Outlet Outlet Pressure
Absolute Pressure - Gage Pressure - Gage Temperature Temperature Pressure - Gage (<0.5s) - Gage
bar (PSI) bar (PSI) bar (PSI) C (F) C (F) bar (PSI) bar (PSI)
Industrial 0.9 (13.2) 0 to 0.36 1.4 55 60 228 (3300)-25VMQ 250 (3625)-25VMQ
1.0 (14.7)- (0 to 5.0) (20) (131) (140) 207(3000)- 228 (3300)-
45VMQ 35&45VMQ 35&45VMQ