SPIGOT GLASS RAILING @1.5KPa
SPIGOT GLASS RAILING @1.5KPa
,6 3DUW
&RGH2I3UDFWLFH)RU'HVLJQ/RDGV)RU%XLOGLQJV 6WUXFWXUHV ,PSRVHG/RDGV
,6 3DUW
&RGH2I3UDFWLFH)RU'HVLJQ/RDGV)RU%XLOGLQJV 6WUXFWXUHV :LQG/RDGV
,6 3DUW
&ULWHULD)RU(DUWKTXDNH5HVLVWDQW'HVLJQ2I6WUXFWXUHV *HQHUDO3URYLVLRQV %XLOGLQJV
,6
*HQHUDO&RQVWUXFWLRQ,Q6WHHO &RGH2I3UDFWLFH
03.1.2.2..SCI P291
Structural Steel Design of Stainless Steel
03.1.3..Aluminium
,6
&RGH2I3UDFWLFH)RU8VH2I$OXPLQLXP$OOR\V,Q6WUXFWXUHV
$6 3$57
$OOXPLQLXP6WUXFWXUHV3DUW$OORZDEOH6WUHVV'HVLJQ
03.1.4..Glass
03.2..Software References
03.2.1..Structural Analysis
i..Staad Pro-2007
03.2.2..Anchor Bolts
i..Compufix : 8.4 - Fischer Anchor
ii..Profis : 2.7.3 - Hilti Anchor
iii..Mungo Fix Cal- Fastening Design Ver:01
03.2.3..Glass
i..Window Glass Design - 2004
04.Material Properties [ As per IS:8147-1976]
kN kN
L'HQVLW\ ρal ≔ 27.1 ――
3
ρal61 ≔ 27.1 ――
3
m m
Page
Page33ofof187
04.4..Glass [Annealed, HS & FT Glass] [As per AS-1288: 2006]
kN
i..Density ρss ≔ 25 ――
3
m
Page
Page44ofof187
06.Loading & Pemissible Deflections
Loading
06.1..Max Dead Load of Glass
kN
06.2..Max Design Wind Pressure WL ≔1.5 ―― WL = 1.5 kPa
2
m
Page
Page55ofof187
Design check for Glass
Check for glass deflec on
Max defelec on under Serviceability load( δm ) δm ≔ 23 mm
Hp
Permissible defelec on δp ≔ ―= 33.6 mm
(Can lever) 30
Hence the Proposed Glass is Safe in Deflec on
Page 6 of 18
Check for Stresses in SS SPIGOT
N
Max stress on glass σ ≔ 216 ―― {Load case 11‐comb case 6
mm 2 (1.5DL+1.5LL)}
N
Max stress on glass σi ≔ σ = 216 ―― With 1.5 FOS
mm 2
N
Prmissible stress for SS SPIGOT σp ≔ 220 ――
mm 2
Since σi < σp = 1
Hence the Proposed Glass is Safe in Strength
12mm PLATES WITH BASE
PLATE
25mm FLAT BAR
Page 7 of 18
CHECK FOR BOLTS
REACTIONS
W ≔ 1.5 kPa
kN
LL ≔ 0.75 ―
m
l ≔ 1.010 m
R3 ≔ LL ⋅ l = 0.758 kN
L ≔ 0.505 m
R3
2
R4 ≔ ― ⋅ L = 3.643 kN
W⋅l ⋅L l1
R1 ≔ ――― = 0.386 kN ⋅ m
2
l1 ≔ 105 mm
R1
R2 ≔ ― = 3.68 kN
l1
Factored Loads : 1.5DL+1.5WLZ
Fx ≔ 0 kN
Fy ≔ 0 kN
Fz ≔ R2 = 3.68 kN
Mx ≔ 0 kN ⋅ m
My ≔ 0 kN ⋅ m
Mz ≔ 0 kN ⋅ m
Factored Loads
Fx_f ≔ Fx = 0 kN
Fy_f ≔ Fy = 0 kN
Mx_f ≔ Mx = 0 kN ⋅ m
My_f ≔ My = 0 kN ⋅ m
Mz_f ≔ Mz = 0 kN ⋅ m
Page 8 of 18
Check for M10 SS Bolt (SS‐316 With property Class‐70)
Dia of SS BoltUsed ds ≔ 6 mm
No of Bolt ns ≔ 4
Max Forces / bolt
0.785 ⋅ π ⋅ ds 2
Area of Bolt As ≔ ――――= 22.195 mm 2
4
Strength of SS 316 Bolt pss1 ≔ 310 MPa pts ≔ 450 MPa
Check for Interac on Equa on
Frv_b Ft_b
―― + ―― = 0.829 0.83 < 1.0 Hence Safe
Pss Pts
Page 9 of 18
CHECK FOR ANCHORS:
Page 10 of 18
www.hilti.in Profis Anchor 2.9.1
Company: Page: 1
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 19-Mar-21
E-Mail:
Specifier's comments:
1 Input data
Anchor type and diameter: HST3-R M12 hef2
Return period (service life in years): 50
Effective embedment depth: hef = 70 mm, hnom = 80 mm
Material: A4
Evaluation Service Report: ETA-98/0001
Issued I Valid: 02-Oct-19 | -
Proof: Design method ETAG (No. 001 Annex C/2010)
Stand-off installation: eb = 0 mm (no stand-off); t = 12 mm
Anchor plate: lx x ly x t = 60 mm x 200 mm x 12 mm; (Recommended plate thickness: not calculated
Profile: no profile
Base material: uncracked concrete, C25/30, fc,cube = 30.00 N/mm2; h = 250 mm
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement
Reinforcement to control splitting according to ETAG 001, Annex C, 5.2.2.6 present.
R
- The anchor calculation is based on a rigid anchor plate assumption.
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
Page 11 of 18
www.hilti.in Profis Anchor 2.9.1
Company: Page: 2
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 19-Mar-21
E-Mail:
Anchor forces are calculated based on the assumption of a rigid anchor plate. 1
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
Page 12 of 18
www.hilti.in Profis Anchor 2.9.1
Company: Page: 3
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 19-Mar-21
E-Mail:
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
Page 13 of 18
www.hilti.in Profis Anchor 2.9.1
Company: Page: 4
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 19-Mar-21
E-Mail:
Steel failure
bN bV a Utilization bN,V [%] Status
0.886 0.102 1.000 83 OK
(bN + bV) / 1.2 ≤ 1.0
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
Page 14 of 18
www.hilti.in Profis Anchor 2.9.1
Company: Page: 5
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 19-Mar-21
E-Mail:
Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements are
valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not included in
this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
7 Warnings
• The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.). This
means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be
sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum required anchor plate
thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate
assumption is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the existing conditions and
for plausibility!
• Checking the transfer of loads into the base material is required in accordance with ETAG 001, Annex C(2010)Section 7! The software considers
that the grout is installed under the anchor plate without creating air voids and before application of the loads.
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of ETAG 001, Annex C! For larger
diameters of the clearance hole see Chapter 1.1. of ETAG 001, Annex C!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to be
followed to ensure a proper installation.
• The characteristic bond resistances depend on the return period (service life in years): 50
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
Page 15 of 18
www.hilti.in Profis Anchor 2.9.1
Company: Page: 6
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 19-Mar-21
E-Mail:
8 Installation data
Anchor plate, steel: - Anchor type and diameter: HST3-R M12 hef2
Profile: no profile Installation torque: 0.060 kNm
Hole diameter in the fixture: df = 14 mm Hole diameter in the base material: 12 mm
Plate thickness (input): 12 mm Hole depth in the base material: 90 mm
Recommended plate thickness: not calculated Minimum thickness of the base material: 140 mm
Drilling method: Hammer drilled
Cleaning: Manual cleaning of the drilled hole according to instructions
for use is required.
30 30
30
2
100
140
x
100
1
30
30 30
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
Page 16 of 18
www.hilti.in Profis Anchor 2.9.1
Company: Page: 7
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 19-Mar-21
E-Mail:
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
Page 17 of 18
HST3 (-R) subject to:
Anchor size M8 M10 M12 M16 M20 M24
Hammer drilling*
DD-30W, DD-EC1
Setting tool*
Setting tool HS-SC -
- TE-CD, TE-YD
Page 18 of 18