TopTronic

The intelligent boiler management


controller for perfect operation of
heating and hot water systems.
TopTronic
For perfect control of heating and hot water systems
for single and multiple boiler arrangements.

State-of-the-art Display showing date and time,


technology boiler and DHW temperatures.
The TopTronic control system
Flip down access cover for
brings together Hoval's programming either manually or via
considerable experience in a PC link.
the field of heating & hot
Adjustable setpoint for room
water control, together with a
temperature during night time/
high performance micro- standby operation.
processor controls package.
Multi-functional switch with 3
individual time programmes, 3
The result is a simple user- additional operating positions and
friendly operating platform positions for hand and standby
that controls individual operation (with frost protection).
heating and hot water
Adjustable setpoint for room
systems and optimises temperature during daytime
energy conservation. operation.

User operating instruction sheet.

... today's solution for all users.


Simple programme Perfect communication Main operating features
selection The interface between Several TopTronic control
Programme selection at the TopTronic controllers and options are available for
boiler is by use of the centre room sensors is via a databus matching with the Hoval boiler
rotary switch. The use of network. range.
clearly defined symbols for
each of the operating Remote fault finding ● Up to two variable
positions ensures operation is Remote diagnosis is possible temperature and one
Boiler control package
both simple and error-free. via a telephone modem link. constant temperature
Boiler TopTronic AF zone can be linked to
Commissioning and Calendar clock each controller.
servicing TopTronic The current date and time are ● Two individual weather
Commissioning and servicing pre-set during manufacture. sensors can be added per
personnel can access the controller.
TopTronic
TopTronic controller on a The controller will function for ● Each variable temperature
Standard Interface

separate level to the user. up to five years in the event zone can be weather
This avoids the need to alter of a power interruption. compensated and linked to
programme settings made by Programming via a a room sensor if required.
Laptop or PC
the user. Access is gained Summer/winter operation is ● Each controller will also
via a password system. automatically changed over control a calorifier primary
by the built-in calendar clock. pump for DHW
Data interrogation temperature regulation.
and input Boiler sequencing ● Can be interfaced with all
All operating parameters can The Hoval TopTronic system types of burner controls.
be read and changed is suitable for sequencing two
manually at the controller. Remote diagnosis/
boilers with either on/off,
Alternatively programming via fault finding via modulating or pre-mix
telephone
a PC can be done using the modulating burner controls.
RS485 port.
Optional Interface

Remote monitoring
and adjustment via
RS10 room station
TopTronic
For on site, or remote plant monitoring.

Safety functions
The TopTronic control has in-
built safety functions to
ensure continued safe
operation of the plant at all
times. These include frost
protection, minimum and
maximum temperature limits
Comprehensive display
and boiler start protection.
As well as indicating the time For gas boilers with modulating pre mix burner
Clearly defined operating
and boiler/DHW temperatures,
levels ensure system integrity
the display will also show
is maintained.
operating conditions, burner
run times (and starts) and
fault conditions. Optional RS room
stations
Individual time The RS10 room station can
programme selection be remotely connected to any
Three individual time Hoval boiler fitted with a
programmes can be pre-set TopTronic controller, to provide
to meet the needs of the remote monitoring of boiler
For small oil and gas boilers with pressure jet or atmospheric burner
end-user. status and adjustment of pre-
programmed settings within
1
the TopTronic controller.

These include:
1 2
● Room temperature.
1) Save ● Heating and hot water
7 days with 2 cycles each programmes.
● Absent, party and holiday
2
settings.
For medium and large oil and gas boilers with pressure jet burners

1 2 Databus connections
2) Standard Up to two TopTronic controllers can be fitted directly into
7 days with 2 cycles each the boiler control panel on most models (see product
brochures for details), enabling control of up to four
3
variable temperature, two constant temperature and a
calorifier primary circuit. These are linked together by
1 2
databus connections. On the UltraGas AM and TopGas
condens boilers this gives a direct link to the modulating
3) Comfort
7 days with 2 cycles each pre-mix controls.

These programmes enable Separate control panel


the heating and hot water Use of the databus
systems to best match the connections will also allow
use of a facility, thus
The display normally indicates up to five controllers to be
maintaining a comfortable
and energy efficient date, time and room linked together. With large
environment. temperature together with installations the TopTronic
outdoor/system temperatures, can be mounted in a
Efficient operation parameter settings and fault separate control panel if
Economic and environ- conditions. In addition the required.
mentally friendly performance RS10 provides the facility to
are at the heart of the new ‘block programme’ time clock
Hoval TopTronic system. settings.

These include: The RS30 room station is


● Reduced burner stop/start available to link directly to a
cycling to improve single Hoval UltraGas or
emissions TopGas boiler only (i.e. without
● Optimised starting facility a TopTronic controller fitted),
with start stages and and provides the same
selectable heating curves features as the RS10, except
● Two stage or modulating that it will only control a single,
burner control directly compensated circuit.
TopTronic
Typical TopTronic Applications.

Selection of the TopTronic Controller

TopTronic Controller Type - TT The table shows the TopTronic


Hoval boiler model Controller options available for
1•B 1•33•B 2•B 2•3•B 2•33•B 22•3•B 22•33•B 20•3•B each Hoval boiler model.
UltraGas AM condens ● ●
TopGas condens ● ● Selection Options
TT ● TopTronic
AtmoGas LN ● ● ● 1 ● Pre-mix modulating burner
Primo ● ● ● 2 ● On/off atmospheric or
● pressure jet burner
Mini-3 ● ●
20 ● Modulating pressure jet
Euro-SR ● ● ● ● ● ● burner (with servo motor)
Cosmo ● ● ● ● ● ● 22 ● High/low atmospheric or
pressure jet burner
Equinox Eq ● ● ● ● ● ● 3 ● Variable temp. zone (x1)
Uno-3 ● ● ● ● ● ● 33 ● Variable temp. zones (x 2)
B ● Calorifier primary
SR-plus ● ● ● ● ● ●
pump control &
ST-plus ● ● ● ● ● ● constant temp. zone (x1)

Selection Key
TT •2 2 •3 3 •B

TopTronic Calorifier primary


pump control
High/low Variable & constant
atmospheric or temperature temperature
pressure jet burner zones (x2) zone (x1)

Typical TopTronic application


Variable temperature zones (x2), constant temperature
zone (x1) and DHW generation suitable for
TopTronic 233B, 2233B, 133B Legend:
VL = Flow
BA1 BA2 RL = Return
Heating system circuits KK = Constant temp circ. pump
VL RL VL RL VL RL MK1 = Variable temp circ. pump (zone 1)
BV1 BV2 MK2 = Variable temp circ. pump (zone 2)
RS10 BV1 = Hot water temp sensor 1
KK MK1 MK2
BV2 = Hot water temp sensor 2
BW
BA1 = External temp sensor 1
BA2 = External temp sensor 2
SP BW = DHW temp sensor
SP = Calorifier primary pump
RS10 = Optional room station
Calorifier Boiler Note: Boiler sensor & burner controls not shown for simplicity.
TopTronic December 2002

Conservation of Energy
Protection of the Environment
Hoval Limited, Northgate, Newark, Notts NG24 1JN
Telephone: 01636 672711 Fax: 01636 673532 e-mail:boilersales@hoval.co.uk www.hoval.co.uk

Hoval follows a policy of continued improvement and reserves the right to change specifications without notice.