Professional Documents
Culture Documents
Gepon Olt SFP Transceiver
Gepon Olt SFP Transceiver
GOXS-BI4312-20PON+++
Features:
Single fiber bi-directional data links symmetric 1.25Gbps application
1490nm continuous-mode DFB laser transmitter and 1310nm burst-mode APD-TIA receiver
Reset-less burst-mode receiver simply the system design
More than 24dB wide dynamic range
0 to 70°C operating case temperature,
Single 3.3V power supply
Digital diagnostic monitoring interface
Digital burst RSSI function to monitor the input optical power level
LVPECL compatible data input/output interface
LVTTL transmitter disable control
LVTTL transmitter laser fault alarm
LVTTL receiver loss of signal indication
Low EMI and excellent ESD protection
Class I laser safety standard IEC-60825 compliant
RoHS-6 compliance
Applications:
Gigabit Ethernet Passive Optical Networks (GEPON) 20Km 1:32 application or 10Km
1:64 application.
Relative Humidity RH 5 85 %
Receiver Section:
Note:
Extinction Ratio ER 9 dB 3
Eye Mask for Optical Output Compliant with IEEE Std 802.3ah™-2004(Figure 1)
Receiver Section:
1:32
20
Max. Supported Link application
Note:
1. EOL,over temperature.
2. Launched into SMF.
3. PRBS 27-1 test pattern @1.25Gbit/s.
4. Bessel-Thompson Filter OFF.
5. Measured with PRBS 27-1@1.25Gbps BER ≤1×10-12
6. Figure
RSSITIMING SEQUENCE
Pin Assignment
Diagram of Host Board Connector Block Pin Numbers and Name
Notes:
1. Circuit ground is internally isolated from chassis ground.
2. Laser output disabled on TDIS >2.0V or open, enabled on TDIS <0.8V.
The SFP modules implement the 2-wire serial communication protocol as defined in the SFP -
8472. The serial ID information of the SFP modules and Digital Diagnostic Monitor parameters
can be accessed through the I2C interface at address A0h and A2h. The memory is mapped in
Table 1. Detailed ID information (A0h) is listed in Table 2. And the DDM specification at address
A2h. For more details of the memory map and byte definitions, please refer to the SFF-8472,
“Digital Diagnostic Monitoring Interface for Optical Transceivers”. The DDM parameters have
been internally calibrated.
3-10 8 Transceiver
11 1 Encoding NRZ(03h)
19 1 Reserved
36 1 Reserved
60-62 3 Reserved
Extended ID Fields
92-94 3 Reserved
Data
Address Parameter Accuracy Unit
96-97 Transceiver Internal Temperature ±3.0 °C
Recommended Circuit