Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

P30 Series P30 Series

Features 8meters
Portable Water Quality Meters
including
pH dual channel ION
modes

As low as 1/30 ORP


EC
DO

the power consumption


(compared to previous models)

Waterproof
Construction

1000 Data
Points Memory
Low Power Consumption & Waterproof
Construction Perfect for Field Measurements
■ Can use rechargeable
nickel-hydrogen batteries
Enables you to dramatically reduce battery waste.
( Rechargeable nickel - hydr ogen A A bat teries are sold
separately.)


Improved indicator that is easier to read
Dual channel meters that can display
two items simultaneously
The custom LCD indicators are 1.2 times larger
than previous models, making them easier to read.
Additionally, dual channel meters can display two
items simultaneously. This makes it easier to read
data for two separate items in real time.

■ ■
1000 Data points memory capacity Superb expandability(except HM-30P、RM-30P)
Can specify auto memory at fixed time intervals* Can be connected to PCs, external printers,
recorders, and other devices
Ideal for brief (half day) simple monitoring, etc.
*Short interval memory function: 1 sec. ‒ 99 min. 59 sec., Desktop-level expandability allows you to manage
 or Long interval memory function: 2 min. ‒ 99 hr. 59 min.
data easily.
(For the long interval memory function, the power goes
OFF [into sleep mode] after the first minute measurement
and remains off until the next measurement is made.)

■ Two year warranty for the main unit ■ Supporting functions for enhanced validation
(Sensors and other parts are not covered under Utilizing the concepts from previous models, we
the warranty.) have developed a number of functions essential
for measurement control, such as sensors with
built-in memory, calibration history, and calibration
interval warning function.

1
Lineup
Please refer to the Specifications & Function table for detailed
information about each model.
(If you want an electrode that is not fitted as standard, please place separate orders for
the “main unit only” and the electrode you need.)

pH Temperature DO Temperature

Portable pH Meter Portable DO Meter


HM-30P DO-31P
Common type for Can be used to conduct
conducting pH measurements field measurements of DO/BOD

Comes with the pH combination Comes with the immersion type DO


electrode GST-2739C. electrode“Cal-memo (Calibration
Memo)”OE-270AA.

Note : For conducting BOD


measurements, please place orders
for the “main unit only”and the“DO electrode for the
incubator bottle OE-470AA”. DO electrode for the
incubator bottle

Electrical Electrical
pH ORP Temperature ch1 Conductivity Resistivity Salinity Temperature
ch2 pH ORP Temperature
Portable pH Meter
HM-31P Portable Electrical
Conductivity/pH Meter
High performance model that
can conduct pH or
WM-32EP
ORP measurements High performance dual channel
type that can simultaneous display
Comes with the pH combination
electrical conductivity and pH
electrode “Cal-memo (Calibration
Memo)” GST-2729C. Comes with the pH combination
electrode“Cal-memo (Calibration
ORP electrode is sold separately. Memo)”GST-2729C, and the c h D u al
an
t y p n el
electrical conductivity cell“Cal-memo
(Calibration Memo)” CT-27112B. e
The ORP electrode is sold separately.

ORP Temperature ch1 pH ORP Ion Temperature


ch2 pH ORP Ion Temperature
Portable ORP Meter
RM-30P Portable Ion/pH Meter
Common type for IM-32P
ORP measurement High performance dual channel
type that can be used for
Comes with the ORP combination
electrode PST-2739C.
ion measurements
Comes with the pH combination
electrode“Cal-memo (Calibration

c h D u al
Memo)”GST-2729C.
an
The ORP electrode, ion electrode, t y p n el
e
and ion standard solutions are sold
separately.

Electrical Electrical
Conductivity Resistivity Salinity Temperature
ch1 DO Temperature
Portable Electrical ch2 pH ORP Temperature
Conductivity Meter
CM-31P Portable DO/pH Meter
Can be used general DM-32P
environmental measurements as
well as pure water measurements High performance dual channel
type that can simultaneous
CM-31P display DO and pH
(for general environmental measurements)
Comes with the electrical conductivity Comes with the pH combination electrode
cell“Cal-memo (Calibration Memo)”CT-27112B. “Cal-memo (Calibration Memo)”GST-2729C,

c h D u al
and the immersion type DO electrode“Cal-
CM-31P-W memo (Calibration Memo)” OE-270AA. an
t y p n el
(for pure water measurements)
Comes with the electrical conductivity cell“Cal-memo (Calibration Memo)” Note : For conducting BOD measurements, e
CT-27111D for pure water, and special flow cell CEF-22A (made of PP). please place orders for the“main unit only”
and the“DO electrode for the incubator
Make sure to select the one that bottle OE-470AA”.
Electrical conductivity cell
best fits your needs. for pure water

2
Full lineup of high-reliability
FREE SEN
D-
sensors for a variety of uses Corresponding sensors

SO
LEA
LEAD-FREE
GST-2729C CT-57101B
GST-2739C CT-57101A

R
■Waterproof sensors perfect for field measurement.
■The“Cal-memo (Calibration Memo)”sensor has built-in memory PST-2729C CT-57101C
PST-2739C
and is designed for validation support.
Can store calibration data and cell constants
Realizes advanced measurement control
Free of setting errors for cell constants and ion species
■Our original built-in float for monitoring the internal solution concentration
allows the user to instantly recognize when the solution needs to be replaced. Cal-memo
(pH/ORP)

【pH/ORP】
Electrode Use Measuring range Lead length Remarks Product Name Code number
1m(Standard) pH4.01 standard solution, 500 mL 143F191
pH combination electrode 3m Electrode with HM-31P/WM-32EP
General environment/ pH0∼14 pH6.86 standard solution, 500 mL 143F192
“Cal-memo (Calibration Memo)” fitted as standard (Lead length: 1 m)
immersion 0∼100℃ 5m pH9.18 standard solution, 500 mL 143F193
GST-2729C Approval of type by Measurement Law
Waterproof type 11m Reference electrode internal
1m(Standard) solution, 50 mL (4 bottles) RE-4-20
Electrode with HM-30P fitted as
3m (3.3 mol/L KCl solution)
pH combination electrode General environment/ pH0∼14 standard
GST-2739C immersion 0∼100℃ 5m (Lead length: 1 m) ORP check solution
Approval of type by Measurement Law (pH4.01 standard solution, 500 mL 143F196
Waterproof type 11m
+ quinhydron powder, 5 packs)
pH combination electrode Organic solvent- pH0∼14
“Cal-memo (Calibration Memo)” 1m Approval of type by Measurement Law Abrasive for ORP electrode, 10mL AO-001
ELP-031 containing solution 0∼100℃
pH combination electrode Fluorinated acid pH2∼12 Replaceable type glass electrode tip
“Cal-memo (Calibration Memo)” 1m
ELP-040 solution-resistance*1 0∼50℃ glass electrode tip (5082L)

ORP combination electrode General environment/ 0∼± 1m(Standard)


“Cal-memo (Calibration Memo)” immersion 2000mV 5m
PST-2729C 0∼100℃
Waterproof type 11m
0∼± 1m(Standard) Electrode with RM-30P fitted as
ORP combination electrode General environment/
PST-2739C
2000mV 5m standard
immersion
Waterproof type 0∼100℃ 11m (Lead length: 1 m)
*1 The glass electrode is affected by fluorinated acid solution. However, because this product is a replaceable type glass
electrode tip, a reduction in operating costs can be expected. In regards to measuring the 1% fluorinated acid solution (at
25℃ , for 1 min.), approximately 1000 measurements can be performed.

【Electrical Conductivity】
Meas.Range Lead Product Name Code number
Cell Use Remarks
(Cell Constant) Length Electrical conductivity cell check solution,
0BI00001
Electrical conductivity cell 0.1mS/m∼ 1m(Standard) C solution, 100 mL (4 bottles)
General environment/ Cell with CM-31P/WM-32EP fitted as
“Cal-memo (Calibration Memo)” 10S/m(250m -1) 5m Electrical conductivity cell check solution,
CT-27112B immersion standard (Lead length: 1 m) 0BI00002
Waterproof type 0∼80℃ 11m B solution,250 mL (2 bottles)
Electrical conductivity cell pure water 5μS/m∼ Cell with CM-31P-W fitted as standard Flow cell (made of PP) CEF-22A
“Cal-memo (Calibration Memo)” measurement/ 20mS/m(1m -1) 1m <Flow cell sold separately.>*2 Flow cell (made of SUS) CEF-23A
CT-27111D flow-through type 0∼80℃ Note: Cannot be connected to WM-32EP.
Electrical conductivity cell 100μS/m∼
General environment/
“Cal-memo (Calibration Memo)” 10S/m(100m -1) 1m
CT-57101B tabletop use
0∼100℃
Electrical conductivity cell High electrical 1mS/m∼
“Cal-memo (Calibration Memo)” conductivity/tabletop 100S/m(1000m -1) 1m
CT-57101A use 0∼100℃
Electrical conductivity cell Low electrical 5μS/m∼ Note: When you perform
“Cal-memo (Calibration Memo)” conductivity/tabletop 1S/m(10m -1) 1m measurements in pure water, you must
CT-57101C use 0∼100℃ use CT-27111D.
*2 If you order the full CM-31P-W set, a flow cell is also fitted as standard.

【DO】
Electrode Use Measuring range Lead Remarks
DO electrode
If a standard membrane is 3m(Standard) Electrode with DO-31P/DM-
General environment/ used:
“Cal-memo (Calibration Memo)” 0∼20mg/L 5m 32P fitted as standard
OE-270AA immersion (Lead length: 3 m)
Waterproof type If a high concentration 11m
membrane is used:
DO electrode 0∼50mg/L 3m(Standard)
General environment/ 0∼50℃ Can be used to conduct zero
“Cal-memo (Calibration Memo)” 5m
OE-570BA immersion (High concentration membrane flow rate measurements
Waterproof type set is sold separately.) 11m
DO electrode Equipped with a stirring function.
“Cal-memo (Calibration Memo)” Incubator bottle 1m (Recommended for conducting
OE-470AA BOD measurements)
0∼20mg/L
DO electrode
Can be used to conduct zero
“Cal-memo (Calibration Memo)” Incubator bottle 1m
OE-470BA flow rate measurements

Product Name Code Remarks


E xclusive to O E - 270A A  One -touch fit ting t y pe featuring an integral
DO module OEC-002 construction made up of an electrode, membrane, and electrolysis solution.
Membrane set for OE-270AA (3 sets) 0CC00001 For OE-270AA (standard measurement)
Membrane set for OE-270AA (high concentration DO) (3 sets) 0CC00002 For OE-270AA (high concentration measurement)
Membrane set for OE-570BA (3 sets) 0CC00023 For OE-570BA (standard measurement)
Membrane set for OE-570BA (high concentration DO) (3 sets) 0CC00024 For OE-570BA (high concentration measurement)
Membrane set for OE-470AA (3 sets) 0CC00003 For OE-470AA (measurement)
Membrane cartridge for OE-470AA (5 pieces) OCT-2502 For OE-470AA (measurement)
Membrane set for OE-470BA (3 sets) 0CC00022 For OE-470BA (measurement)
Underwater stirrer 0SM00002 For OE-270AA/570BA
Electrolysis solution R-9, 50 mL (3 bottles) 0BG00007 For OE-270AA/570BA/470AA/470BA
Sodium sulfite 50 g 143A030 Used for preparing zero solution

3
Portable Water Quality Meters P30 Series Specification and Function Table
Portable pH Portable Portable pH Portable Electrical Portable DO Portable Electrical Portable Portable
Product Name
Meter ORP Meter Meter Conductivity Meter Meter Conductivity/pH Meter Ion/pH Meter DO/pH Meter

(For general environment)


CM-31P
Model Name HM-30P RM-30P HM-31P (For pure water)
DO-31P WM-32EP IM-32P DM-32P
CM-31P-W
pH : Glass electrode pH : Glass
pH : Glass pH : Glass
Glass Platinum Membrane method electrode method
Measuring electrode method AC two-electrode electrode method
electrode electrode type galvanic Electrical conductivity : DO : Membrane
method ORP : Platinum method Ion : Ion electrode
method method cell method AC two-electrode type galvanic cell
electrode method method
method method
Display Custom LCD Custom LCD (simultaneous display of dual channel measured data)

Sensor
ch1 pH ORP pH、ORP Electrical Conductivity DO Electrical Conductivity pH、ORP、Ion DO
Connection
ch2 ─ pH、ORP pH、ORP、Ion pH、ORP

[If standard cell is used] pH : 0.00-14.00


Electrical conductivity : pH : 0.00-14.00 ORP :
0.1mS/m-10S/m [If standard 0-±2000mV
ORP : 0-±2000mV
Electrical resistivity : membrane is used] Temperature :
Temperature :
0.1Ω・m-10kΩ・m DO : 0-100.0℃
0-100.0℃ pH : 0.00-14.00
Salinity (NaCl equivalent 0-20.00mg/L
Saturation rate :
from electrical conductivity) : ORP : [If standard
0-4.00% 0-200% [If standard cell is used] 0- ± 2000mV membrane is used]
pH : Electrical conductivity : DO : 0-20.00mg/L
Temperature : 0-80.0℃ Temperature : Temperature :
0.00-14.00 0.1mS/m-10 S/m 0-100.0℃
pH : ORP : 0-50.0℃ Saturation rate :
Measuring 0.00-14.00 0-±2000mV ORP : Electrical resistivity : Ion : 0-200%
[If cell for pure water is 0.1Ω ・m-10kΩ ・m
Range Temperature : Temperature : 0-±2000mV used] [If high differs Temperature :
0-100.0℃ 0-100.0℃ Temperature: Electrical conductivity : concentration Salinity (NaCl equivalent according to 0-50.0℃
0-100.0℃ 5μS/m-20mS/m membrane is used] obtained by electrical the electrode
DO : conductivity) : 0-4.00%
that is used. [If high concentration
Electrical resistivity : 0-50.0mg/L Temperature : 0-80.0℃ (Temperature membrane is used]
50Ω・m-182kΩ・m measuring function
Saturation rate : DO:0-50.0mg/L
Temperature : 0-80.0℃ 0-500% *If the cell for tabletop is not provided.)
use is used, the
Saturation rate :
Temperature : measuring range differs 0-500%
*If the cell for tabletop
0-50.0℃ according to the cell Temperature :
use is used, the measuring
range differs according to that is used. 0-50.0℃
the cell that is used.

Electrical conductivity : pH : -2.00-16.00


0-200.0μS/m ORP : 0-±2200mV
0-2.000mS/m pH :
0-20.00mS/m Electrical conductivity :
0-200.0μS/m -2.00-16.00
0-200.0mS/m [If standard
0-2.000mS/m ORP :
0-2.000S/m membrane is used] 0-20.00mS/m 0-±2200mV
0-20.00S/m DO : 0-200.0mS/m
0-200.0S/m 0-22.00mg/L 0-2.000S/m [If standard
0-20.00S/m membrane is used]
Electrical resistivity : Saturation rate : pH :
0-200.0S/m DO :
pH : 0.005-2.000Ω・m 0-220% -2.00-16.00 0-22.00mg/L
-2.00-16.00 0-20.00Ω・m Electrical resistivity :
pH : ORP : 0.005-2.000Ω・m ORP : Saturation rate :
0-200.0Ω・m [If high
-2.00-16.00 0-±2200mV ORP : 0-20.00Ω・m 0-±2200 mV 0-220%
Display Range 0-2.000kΩ・m concentration
Temperature : Temperature : 0-±2200mV 0-20.00kΩ・m membrane is used] 0-200.0Ω・m Ion :
-5-110.0°C -5-110.0℃ Temperature : DO : 0-2.000kΩ・m 0.0μg/L-999 g/L [If high
0-200.0kΩ・m 0-20.00kΩ・m
-5-110.0℃ 0-2.000MΩ・m 0-55.0mg/L 0-200.0kΩ・m Temperature : concentration
0-20.00MΩ・m -5-110.0℃ membrane is used]
Saturation rate : 0-2.000MΩ・m
0-20.00MΩ・m DO :
Salinity(NaCl) : 0-550%
0-55.0mg/L
0-4.04% Temperature : Salinity (NaCl) : 0-4.04%
Saturation rate :
Temperature : -5-110.0℃ Temperature : -5-110.0℃ 0-550%
-5-110.0℃ * In regards to the
Temperature :
*In regards to the range, range, the electrical
the electrical conductivity/ conductivity/resistivity -5-110.0℃
resistivity differs according differs according to the
to the cell that is used. cell that is used
Electrical Conductivity/
Resistivity Range Switching ─ Auto/manual ─ Auto/manual ─
Electrical Conductivity/ Can switch between SI Units Can switch between SI Units
Resistivity Unit ─ (S/m, Ω・m) and the previous ─ (S/m, Ω・m) and the previous ─
Switching units (S/cm, Ω・cm). units (S/cm, Ω・cm).
[If standard pH : ±0.02pH pH : ±0.02pH
Electrical membrane is used]
ORP : ±2mV ORP : ±2mV
conductivity : DO : ±0.03mg/L
±0.5%FS Electrical [If standard
Saturation rate : pH : ±0.02 pH membrane is used]
pH : ±0.02pH Electrical ±2% conductivity :
pH : ±0.02pH ORP : ±2mV ±0.5%FS ORP : ±2 mV DO: ±0.03mg/L
Repeatability ORP : ±2mV resistivity : [If high concentration
Temperature : Temperature : ±0.5%FS membrane is used] Electrical Ion : ±0.5%FS Saturation rate : ±2%
(Main unit) Temperature :
±0.2℃ ±0.2℃ DO : ±0.2mg/L resistivity: Temperature : [If high concentration
±0.2℃ Salinity :
±0.5%FS ±0.2℃ membrane is used]
±0.5%FS Saturation rate :
Salinity : ±0.5% FS DO : ±0.2mg/L
Temperature : ±2%
±0.2℃ Temperature : Saturation rate : ±2%
Temperature :
±0.2℃ ±0.2℃ Temperature : ±0.2℃

Switch setting between pH : Auto/Manual


Auto/Manual/None Electrical Conductivity/
(For salinity and auto only) Resistivity :
Temperature Switch setting between
compensation method : Auto/Manual/None
Auto/Manual Linear/pure water (For salinity and auto only) Auto/Manual pH :
Temperature Temperature
Auto/Manual ─ Not applied to dual temperature Auto Auto/Manual
Compensation compensation method : Not applied to
ORP compensation Linear method ORP and ion DO : Auto
Reference temperature : Reference temperature :
25℃ 25℃
Temperature coefficient Temperature coefficient
: 0-9.99% : 0-9.99%
(optional setting) (optional setting)

Capable of Capable of pH : Capable of three-point


pH/ion :
pH : Capable of three-
Cell constant Zero/span calibration point calibration
Calibration three-point ─ three-point Capable of three-
calibration calibration Electrical conductivity : point calibration DO : Zero/span
calibration calibration Cell constant calibration calibration

5
Portable Electrical
Portable pH Portable ORP Portable pH Portable Electrical Portable DO Portable ion/ Portable DO/
Product Name Conductivity/pH
Meter Meter Meter Conductivity Meter Meter pH Meter pH Meter
Meter
(For general environment)
CM-31P
Model Name HM-30P RM-30P HM-31P (For pure water)
DO-31P WM-32EP IM-32P DM-32P
CM-31P-W
Temperature Calibration One-point calibration
Correction function Salinity correction (DO)
Salinity correction
─ Atmospheric pressure ─ Atmospheric pressure
(Called by Key Input) correction correction

Data Memory 1000 data points


Auto Hold Function Provided (Stability threshold : Fixed)
Clock Function Provided (To be shown while conducting a measurement)
Interval Memory Function Provided (Interval: The interval can be specified between 1 sec.-99 min. 59 sec. or 2 sec.-99hr. 59 min.)
Printing Function ─ Can connect the external printer EPS-P30 (option)
Connectable
RS-232C Devices ─ PC or external printer EPS-P30 (option)
Interface*1 Communication
─ Communication system: Start-stop synchronous method Baud rate: 19,200 bps Character length: 8 bits Parity: None Stop bit: 1 bit
Specifications

Number of outputs : 2 Number of outputs : 3 Number of outputs : 2 Number of outputs : 3 Number of outputs : 2 Number of outputs : 2
Measured value Measured value, Measured Measured value, Measured value Measured value
Number of Outputs/

and temperature temperature, value and temperature, (not available and temperature
ch1 ─ and range (only temperature and range (only for ion) and
for electrical for electrical temperature
Items

conductivity/ conductivity/
Analog resistivity) resistivity)
Output Number of outputs : 2 Number of outputs : 2 Number of outputs : 2
*1
ch2 ─ ─ ─ ─ Measured value Measured value (not available Measured value
and temperature for ion) and temperature and temperature
separately as an option
Connecting Cable available

pH : ±700mV
(pH0-14) pH : ±700mV
Electrical conductivity/ (pH0-14)
electrical resistivity/ ORP : ±1V
pH : ±700mV ORP : ±1V
pH : ±700mV salinity : DO/saturation (0-±2000mV) (pH0-14)
(pH0-14) 0-1V FS (0-±2000mV)
rate : resistivity/
Output (each range) 0-1V FS ORP : ±1V DO/saturation
ORP : ±1 V salinity :
─ (each range) (0-±2000mV) rate :
Specifications (0-±2000mV) Range : 0-1V FS
Temperature : (each range) Temperature : 0-1V FS
Temperature : 100mV/range
0-1 V (0-100℃ ) Range : 0-1V (0-100℃ ) (each range)
0-1V (0-100℃ ) Temperature :
0-1 V (0-100℃ ) 100 mV/range Temperature :
0-1V (0-100℃ )
Temperature :
0-1V (0-100℃ )
Waterproof Construction IP67 (Enabled if the sensor is connected and if the external I/O portions are masked) (Can be immersed in water for 1m and 30 min.)
Performance Compensation
Temperature/humidity 0-45°C, 90% or below (no condensation)

AA alkaline battery/
Power Source AA alkaline battery/nickel-hydrogen battery (2 pieces) or special AC adapter (6VA option)
nickel-hydrogen battery (2 pieces)
Power Consumption
(If 3 volt battery is used)*2 Approx. 0.003W Approx. 0.003W Approx. 0.003W Approx. 0.009W Approx. 0.014W Approx. 0.009W Approx. 0.004W Approx. 0.014W
Battery Life Approx. 2000hours Approx. 2000hours Approx. 2000hours Approx. 600hours Approx. 400hours*4 Approx. 600hours Approx. 1500hours Approx. 400hours*4
Outside Dimensions Approx. 68 (w) x 35 (h) x 173 (d) mm
Mass Approx. 280g Approx. 300g
(Including Batteries)

*1) If the sample is earthed, make sure to use RS-232C and analog output in a insulated condition.
If you want to simultaneously (realtime) use RS-232C interface and analog output, you must have the special option cable. Please contact us for details.
*2) The power consumption (consumption current) values shown are for when option devices (e.g. PC, printer) are not connected. If option devices are connected, the power consumption might
be approximately twice as high as the values shown, depending on the model.
*3) Except for when the DO electrode with the stirring function is connected.

Standard Accessories
Portable Electrical
Portable pH Portable ORP Portable pH Portable Electrical Portable DO Portable ion/ Portable DO/
Product Name Conductivity/pH
Meter Meter Meter Conductivity Meter Meter pH Meter pH Meter
Meter
(For general environment)
CM-31P
Model Name HM-30P RM-30P HM-31P (For pure water)
DO-31P WM-32EP IM-32P DM-32P
CM-31P-W
[CM-31P]
Electrical Electrical
placing order for full set

conductivity cell conductivity


Only for customers

DO electrode
ORP CT-27112B cell
pH combination pH combination (Lead length : 1m) pH combination OE-270AA
combination DO electrode CT-27112B
electrode electrode electrode (Lead length : 3m)
electrode [CM-31P-W] OE-270AA (Lead length : 1m)
GST-2739C GST-2729C Electrical GST-2729C pH electrode
PST-2739C (Lead length : 3m) pH combination
(Lead length : 1m) (Lead length : 1m) conductivity cell (Lead length : 1m) GST-2729C
(Lead length : 1m) electrode
CT-27111D (Lead length : 1m)
GST-2729C
Flow cell made of PP (Lead length : 1m)
Standard CEF-22A
Accessories pH4.01 standard 3.3 mol/L KCl pH4.01 standard pH4.01 standard pH4.01 standard pH4.01 standard
solution (100mL) solution (50mL) solution (100mL) solution (100mL) solution (100mL) solution (100mL)
pH6.86 standard pH6.86 standard pH6.86 standard pH6.86 standard pH6.86 standard
solution (100mL) solution (100mL) solution (100mL) solution (100mL) solution (100mL)
3.3 mol/L-KCl Polybeaker 3.3 mol/L-KCl 3.3 mol/L-KCl 3.3 mol/L-KCl 3.3 mol/L-KCl
solution (50mL) (50mL) (3pieces) solution (50mL) solution (50mL) solution (50mL) solution (50mL)
Polybeaker Polybeaker Polybeaker Polybeaker Polybeaker
(50mL) (3pieces) (50mL) (3pieces) (50mL) (3pieces) (50mL) (3pieces) (50mL) (3pieces)
AA alkaline batteries (for initial operation) ( 2 pieces), hand strap, instruction manual

6
Options Designed to fit your needs, from the field to the lab.

For managing data on PC


Product Name Code number Remarks
RS-232C connecting cable 118N062 For PC connection. Lead length: 2 m.

For connecting to a recorder or other devices


Product Name Code number Remarks External printer
Lead length: 1.5 m. Side terminal for connecting to external devices
Analog output cable 118N063 (3 mmY terminal).
(This product cannot be used for HM-30P and RM-30P.)

For data recording


Product Name Code number Remarks
Compact sized printer with chart width of approx. 60 mm.
External printer
EPS-P30 Ordinary printing level is sufficient for long-term data storage
(with connecting cable)
(Cannot connect to HM-30P and RM-30P.)
Printer sheet (20 rolls) P000119
Ink ribbon (1 piece) 0RD00001
*You must have this cable in order to use an external printer
Connecting cable for external 118N061
(EPS-G/EPS-R).

For laboratory use Electrode stand/


Product Name Code number Remarks holder/attachment
AC adapter Ask
Electrode stand
6948810K
(with column and stopper)
Electrode holder 0IB00001 This product cannot be used for DO electrode.
Standard electrode for all P30 series products.
Electrode attachment (DP) 0IB00007
(This product cannot be used for DO electrode.) For ELP-040.
Electrode attachment(G) 0IB00004 For sensors that are for tabletop use.
*Please prepare an electrode stand, an electrode holder, and an electrode attachment.

Carrying case
For field measurement
Product Name Code number Remarks
This product provides a lead length of 5 m or more for waterproof
sensors that are immersed.
Stick holder 0IB00009
If you have trouble reaching a measurement point, you use this
product to safely measure from a position that is more accessible.
This product provides a lead length of 5 m or more for waterproof
Twin stick holder 0IB00010 sensors that are immersed.
Two sensors can be attached.
Can be used for waterproof sensors that are immersed. Anchor for
Anchor (AN-21P) 0IC00001
submerging.
Rope for AN-21P 0IZ00002 1SUS rope
This case allows you to store and carry the main unit, sensor, and Soft case
Carrying case 0DA00001 other accessories, such as the standard solution.
(comes with shoulder belt)
This portable soft case allows you to store the main unit when it is
Soft case SC-10P
connected to a sensor.

Do not operate producuts before


consulting instruction manual.

International Operations:
DKK-TOA Corporation
29-10, 1-Chome, Takadanobaba, Shinjuku-ku, Tokyo 169-8648 Japan
Tel : +81-3-3202-0225 Fax : +81-3-3202-5685

Representative Office (Europe):


DKK-TOA European Representative
St. Johns Innovation Centre, Cowley Rd., Cambridge CB4 0WS UK.
Tel : +44 (0)1223-526471 Fax : +44 (0)1223-709239

http://www.toadkk. co. jp Information and specifications are for a typical system and are subject to change without notice.

Issued on 10/11/2009 A-1-20E

You might also like