LV. Catalogue
6
7
8
Super AE Series
9
1
10
Appearance and Product Structure
11
1
Skeleton
8
10 9 3 4 5 6
7 30
31
28 29
1 2
12 11 26 27
13
14 24 25
15 16
8 ETR unit 18 Under voltage trip device (UVT) 29 Interphase Barrier (BA)
Product Configuration
1 2 3 4 5
Type Standard Connection Drawout type Electrical
accessories accessories
AE630-SW IEC 60947-2 Drawout type Cell switch Auxiliary switch
AE1000-SW EN 60947-2(CE) Horizontal terminal Shorting b-contact Motor charging device
AE1250-SW VDE Vertical terminal Lifting hooks Closing coil
AE1600-SW JIS C 8201-2-1 Front terminal Safety shutter
Shunt trip device
AE2000-SWA GB 14048.2(CCC) Safety shutter lock
Under voltage trip device
AE2000-SW (Marine Approvals) Mis-insertion preventor
Condenser trip device
AE2500-SW LR Test jumper
AE3200-SW GL
AE4000-SWA BV
AE4000-SW DNV
AE5000-SW ABS Fixed type
AE6300-SW CCS
NK
Except AE4000-SW~AE6300-SW
6 7 8 9
Mechanical Electronic Relay Network
accessories trip relay accessories
Push button cover General use Extension module CC-Link® Interface unit
Counter WS type Display PROFIBUS-DP Interface
Cylinder lock Generator protection use Temperature alarm unit MODBUS® Interface
MCR switch unit I/O unit
Terminal cover WM type
Neutral CT
Door frame Special use
External ZCT
Dust cover WB type
VT unit
Interphase barrier Protective coordination use
Mechanical interlock WF type
Door interlock Optional
G1:Ground fault protection
E1:Earth leakage protection
AP:2nd Additional Pre-alarm
N5:Neutral pole 50% protection
1
12
Product Features
High-Performance High-Reliability
The safety of valuable circuits can be securely maintained.
13
3
Product Features
Best Solution
Through Flexible and Various Options, To be Built up the Suitable Functions.
LTD+ STD+ INST / MCR LTD+ STD + INST / MCR INST / MCR
Note : *For optimum protective coordination with upstream and/or downstream protective devices such as fuses
and OCRs, WF relay (WF1/WF2/WF3) are provided.
As for the details about WF relay, please make inquiries.
3
Ground fault (1) Neutral pole (2)
protection (GFR) Earth leakage (ER) 2nd Additional Pre-alarm 50% protection
Note (1) : Combination with ZCT
(2) : With "N5" optional module, Neutral pole protection will be changed from 100% (standard) to 50%.
1 Power supply 3
It is neccessary for Display and P1 9$&'&
LEDs. (see page 19, 20.) P2 9'&
P3 9$&9'&ZLWKRXWSXWFRQWDFW
P4 9'&ZLWKRXWSXWFRQWDFW
P5 9'&ZLWKRXWSXWFRQWDFW665
2
Temperature alarm (TAL)
When TAL sensor is installed in the breaker, temperature alarm is
operative. When the temperature of main contact exceeds normal level,
temperature alarm is indicated by LED on main setting module and also the
output contact is made energize if power supply with output contact is
installed. It is possible to know temperature rising which is caused by wear
of main contact because TAL sensor is installed near main contact. When
the temperature of main contact goes down to the normal level,
temperature alarm turns off automatically.
There are 2 types of display module. One is the ETR attachment type (DP1). Another is the panel
attachment type (DP2), which can be connected to extension terminals of control circuit with 2m cable.
2 units of display modules (DP1 and DP2) can be attached on one breaker. (As for outline dimensions
of DP2, refer to page 53.)
Note;
Extension module (EX1) is required.
VT unit (VT) is required to display the measured data except load current.
1
14
Network
By using various application softwares for PLC, users can also connect to the
Personal network SCADA system.
Computer
MELSECNET/10
MELSECNET/10
Interface card CC-Link® / PROFIBUS-DP / MODBUS®
AE-SW
The length of the cable for interface unit is 2m. Note: Some device types are excluded.
Note:
Extension module (EX1) is required.
BIF-MD (MODBUS®(RS-485)) VT unit (VT) is required to transmit the measured data except load current.
15
5
Electronic Trip Relay (Feature)
1
16
17
7
18
WS-V & WSS Moulded-Case Circuit Breakers
current-limiting performance
19
9
The new electronic circuit breakers (with display) and MDU breakers
can display various measurement items
This will enable energy management through “visualization”, which leads to energy saving.
Display Current
Alarm
in each phase
2
20
List of Product Models - WSS
Frame A
Series
400 630 800 1000 1250 1600
NF-C NF400-CW NF400-CW NF800-CEW
Moulded-case circuit breakers
Economy type
Economy type
NV400-SW
NV-S NV800-SEW
Standard type NV400-SEW NV630-SEW
NV-H
High-performance type NV400-HEW
NV630-HEW NV800-HEW
NV400-REW
NV-U
Ultra current-limiting type
NV-C
Earth-leakage circuit breakers for CE Marking
Economy type
NV400-CW NV630-CW
NV400-SW NV630-SW
NV-S NV800-SEW
Standard type NV400-SEW NV630-SEW
NV-H
High-performance type NV400-HEW
NV630-HEW NV800-HEW
NV400-REW
NV-U
Ultra current-limiting type
Motor-protection
MB
breakers
Motor breaker
UL listed products
NF-UL NV-UL
Earth-leakage protector
UL489 Listed
UL489 Listed
Moulded-case circuit breaker
Moulded-case circuit breaker
( Detailsuponwillrequest.
be available
)
21
1
Abundant Accessories and Easy Installation
2
22
Intelligent - Measuring & Communicating
0'80HDVXULQJ'LVSOD\8QLWZLWK1)$)WKHFLUFXLWEUHDNHUVPHDVXUHDQG
GLVSOD\WKHORDGFXUUHQWOLQHYROWDJHHOHFWULFSRZHUHOHFWULFHQHUJ\
KDUPRQLFFXUUHQWOHDNFXUUHQWDQGSRZHUIDFWRUWRUHDOL]HGHWDLOHG
HQHUJ\FRQWURO7KH\VXSSRUWFXVWRPHUVҋHQHUJ\VDYLQJFRQWURO
7KHPHDVXULQJGLVSOD\XQLWFDQEHLQVWDOOHGRQWKHERG\RUSDQHO
&RPSDFWZKLWHPHDVXULQJXQLW
0HDVXULQJGDWDFDQEHWUDQVPLWWHGWRD3&RUD3/&WKURXJKCC-Link
$/$;ZLWKCC-LinkWUDQVPLVVLRQ
23
3
2
24
MCB,
C , RCCB,
CC , Isolator
so o Range
ge
25
5
Distribution Boards
Manufactured with the help of high precision deep drawn tools (no welding involved), and treated
with nine tank phosphating process these distribution boards provide perfect quality and high corro-
sion resistance.
assembly which facilitates easy removale of intermediate player and minimises the assembly time.
SALIENT FEATURES
» Tested in compliance with IEC 61439 - 3 standards from third party and in-house test labs
» IP 43 protection
» Manufactured by deep drawn tools for precise dimensional accuracy, weld free process
» Additional safety for users with help of Shrouded Neutral links, Insulated bus bar and door
earthing
» Reversible and easy mounting of door on either side of the board
» Detachable Din rail assembly (cassette type) for ease in wiring during installation and mainte-
nance
» Excellent aesthetics - Pure white in colour to suit any type of interior walls, high corrosion and
scratch resistance
» Cement protection sheet provided as standard for protection during masonry work
2
26
Metallic Distribution Boards-Range
27
7
2
28
29
9
3
30
New MS-T Magnetic Contactors
31
1
New MS-T Magnetic Contactors
Easy branch circuit wiring with Manual Motor Circuit Breaker and
optional connection conductor unit
Easy wiring is available for the new
MS-T Series by using the Manual
Motor Circuit Breaker and optional
connection conductor unit, contributing
your productivity improvement.
he
it e l im inates t
U n
f wires
need o
SCCR
value
increased
3
32
MS-N-Magnetic Contactors
33
3
MS-N-Magnetic Contactors
3
34
35
5
MS-N Overview
3
36
Motor Protection Relays
37
7
Motor Protection Circuit Breaker
3
38
39
9
4
40
Optional Unit
41
1
Electronic Motor Protection Relays
4
42
Solid State Contactors
Series US-K
6.1 Features
Ideal for heavy duty applications Silent operation
The contactor contains no moving parts, so its reliability Since the contactor has no moving part, noise is
and long life are assured even in high cycling eliminated.
applications.
Easy connection
R S T C1(+)
The power circuit elements are electricaly insulated main circuit control circuit
from the heatsink.
No insulation of the heatsink is required.
U V W C2(–)
Compact size
OFF state ON state
The contactor consists of a small size body and
heatsink.
43
3
MITSUBISHI ELECTRONIC MULTI-MEASURING INSTRUMENT
EXPAND LINE UP
44
4 4
ME96 Super-S Series Features
45
5
4
46
47
7
48
48
Mitsubishi Inverter Series for
HVAC Application Common
49
9
5
50
Mitsubishi Drive Highlighted Point
51
1