LV. Catalogue

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 50

5

Six Stoutly Reasons for


Mitsubishi LVS

6
7
8
Super AE Series

9
1
10
Appearance and Product Structure

11
1
Skeleton
8
10 9 3 4 5 6
7 30

31

28 29

1 2

12 11 26 27

13

14 24 25

15 16

1 Air circuit breaker 12 Dust cover (DUC) 22 Counter (CNT)


21
17 2 Cradle 13 Push button cover (BC-L) 23 Cylinder lock (CYL)
20 3 CC-Link® Interface unit 14 Auxiliary switch 24 Door interlock (DI)
18 standard (AX)
4 PROFIBUS-DP Interface unit 25 Mechanical interlock (MI)
15 Auxiliary switch
5 MODBUS® Interface unit high capacity type (HAX) 26 Safety shutters (SST)
22 23
6 I/O unit 16 Shunt trip device (SHT) 27 Safety shutter lock (SST-LOCK)
19
7 Extension module 17 Closing coil (CC) 28 Cell switch (CL)

8 ETR unit 18 Under voltage trip device (UVT) 29 Interphase Barrier (BA)

9 Main setting module 19 UVT-controller (U-CON) 30 Horizontal terminal

10 Optional setting module 20 Condenser trip device (COT) 31 Vertical terminal

11 Door frame (DF) 21 Motor charging device (MD)

Product Configuration
1 2 3 4 5
Type Standard Connection Drawout type Electrical
accessories accessories
AE630-SW IEC 60947-2 Drawout type Cell switch Auxiliary switch
AE1000-SW EN 60947-2(CE) Horizontal terminal Shorting b-contact Motor charging device
AE1250-SW VDE Vertical terminal Lifting hooks Closing coil
AE1600-SW JIS C 8201-2-1 Front terminal Safety shutter
Shunt trip device
AE2000-SWA GB 14048.2(CCC) Safety shutter lock
Under voltage trip device
AE2000-SW (Marine Approvals) Mis-insertion preventor
Condenser trip device
AE2500-SW LR Test jumper
AE3200-SW GL
AE4000-SWA BV
AE4000-SW DNV
AE5000-SW ABS Fixed type
AE6300-SW CCS
NK

Except AE4000-SW~AE6300-SW

6 7 8 9
Mechanical Electronic Relay Network
accessories trip relay accessories
Push button cover General use Extension module CC-Link® Interface unit
Counter WS type Display PROFIBUS-DP Interface
Cylinder lock Generator protection use Temperature alarm unit MODBUS® Interface
MCR switch unit I/O unit
Terminal cover WM type
Neutral CT
Door frame Special use
External ZCT
Dust cover WB type
VT unit
Interphase barrier Protective coordination use
Mechanical interlock WF type
Door interlock Optional
G1:Ground fault protection
E1:Earth leakage protection
AP:2nd Additional Pre-alarm
N5:Neutral pole 50% protection
1
12
Product Features
High-Performance High-Reliability
The safety of valuable circuits can be securely maintained.

13
3
Product Features
Best Solution
Through Flexible and Various Options, To be Built up the Suitable Functions.

Electronic Trip Relay Main setting module 1


With interchangeable & add-on modules, flexible functions built up.

:6 WM1 WB1


GeQerDWRU
:6 GeQerDl Xse WM2 SURWeFWLRQ XVe WB2 6SeFLDl Xse
:6 WM3 WB3

LTD+ STD+ INST / MCR LTD+ STD + INST / MCR INST / MCR

Note : *For optimum protective coordination with upstream and/or downstream protective devices such as fuses
and OCRs, WF relay (WF1/WF2/WF3) are provided.
As for the details about WF relay, please make inquiries.

Optional setting module 2


With optional setting modules, GFR, ER etc are added easily.
G1 E1 AP N5

3
Ground fault (1) Neutral pole (2)
protection (GFR) Earth leakage (ER) 2nd Additional Pre-alarm 50% protection
Note (1) : Combination with ZCT
(2) : With "N5" optional module, Neutral pole protection will be changed from 100% (standard) to 50%.

1 Power supply 3
It is neccessary for Display and P1 9$&‡'&
LEDs. (see page 19, 20.) P2 9'&

P3 9$&9'&ZLWKRXWSXWFRQWDFW

P4 9'&ZLWKRXWSXWFRQWDFW

P5 9'&ZLWKRXWSXWFRQWDFW 665
2
Temperature alarm (TAL)
When TAL sensor is installed in the breaker, temperature alarm is
operative. When the temperature of main contact exceeds normal level,
temperature alarm is indicated by LED on main setting module and also the
output contact is made energize if power supply with output contact is
installed. It is possible to know temperature rising which is caused by wear
of main contact because TAL sensor is installed near main contact. When
the temperature of main contact goes down to the normal level,
temperature alarm turns off automatically.

Display module (DP1/DP2)


This is the module for display and setting of the various information like measured value, trip and alarm
status, ETR status for display and output contacts setting etc...
1. Multi display of measuring element It enables to easily monitor the comparison of each measuring
element with its multi display (4 phases multi display of load current and voltage) on one screen.
2. wo-color back light Under trip or alarm, back light color changes from green to red automatically,
which visually shows an abnormal situation.
3. Graphical display By adopting dot matrix type LCD, graphical display such as bar graph display of
load current, harmonic currents and characteristic curve is available.

There are 2 types of display module. One is the ETR attachment type (DP1). Another is the panel
attachment type (DP2), which can be connected to extension terminals of control circuit with 2m cable.
2 units of display modules (DP1 and DP2) can be attached on one breaker. (As for outline dimensions
of DP2, refer to page 53.)
Note;
Extension module (EX1) is required.
VT unit (VT) is required to display the measured data except load current.

1
14
Network

Interface unit (BIF-CC/BIF-PR/BIF-MD)


These Interface units can expand the future possibility in various communication and Intelligent control.
2
1 Applicable to various open networks.
These units are applicable to various open network systems such as CC-Link®,
PROFIBUS-DP and MODBUS® (RS-485), which can be built in easily.

2 Intelligent control by Multi-data communication


It comes into being the Intelligent control by Multi-data communication through these
BIF-CC (CC-Link®)
interface units to PLC/SCADA, which transfer the measurement Information, setting values,
error information and trip and alarm informations.

By using various application softwares for PLC, users can also connect to the
Personal network SCADA system.
Computer

MELSECNET/10
MELSECNET/10
Interface card CC-Link® / PROFIBUS-DP / MODBUS®

BIF-PR (PROFIBUS-DP) Interface I/O Unit


Unit
PLC

Eco Monitor Pro ME96NSR


MDU

AE-SW

The length of the cable for interface unit is 2m. Note: Some device types are excluded.

Note:
Extension module (EX1) is required.
BIF-MD (MODBUS®(RS-485)) VT unit (VT) is required to transmit the measured data except load current.

I/O unit (BIF-CON)


The Input & Output Controlling Unit (BIF-CON) is available for the remote controlling and remote
monitoring of the breaker condition through the various network systems.
With this BIF-CON unit in addition to the Interface Unit, it become possible to control the breaker
remotely, like a ON or OFF operations or Spring-charging.

Function Description Note


Breaker ON operation 1a contact for Closing coil (CC)

1a contact for Shunt trip device (SHT)


Control Breaker OFF operation
(not applicable for AC380-500V rating)

BIF-CON Spring charge 1a contact for Motor charging (MD)

For BIF-CC and BIF-MD, Max. 3 contacts


Monitor Digital Input (DI) monitoring monitoring are available.
For BIF-PR, 1 contact monitoring is available.

15
5
Electronic Trip Relay (Feature)

indicator LED and Additional function modules like


EX1, DP1, etc

Optional setting module

PRE-ALARM (PAL LED and Current setting dial)

1
16
17
7
18
WS-V & WSS Moulded-Case Circuit Breakers

electronic trip relay.

current-limiting performance

Current Limiting Performance

19
9
The new electronic circuit breakers (with display) and MDU breakers
can display various measurement items
This will enable energy management through “visualization”, which leads to energy saving.

The display is on the circuit breaker body and


shows circuit information.
Detailed setting can be done on the display.
The display turns red during alarms.

Display Current
Alarm
in each phase

Electronic Circuit Breaker Measuring Display Unit


(with display) Breaker

2
20
List of Product Models - WSS
Frame A
Series
400 630 800 1000 1250 1600
NF-C NF400-CW NF400-CW NF800-CEW
Moulded-case circuit breakers

Economy type

NF400-S NF630-SW NF800-SDW NF1250-SEW NF1600-SEW


NF-S NF1000-SEW
Standard type NF400-SE NF630-SEW NF800-SEW NF1250-SDW NF1600-SDW
NF-H NF400-HEW NF630-HEW NF800-HEW
High-performance type

NF400-REW NF630-REW NF800-REW

NF-U NF400-UEW NF800-UEW


Ultra current-limiting type
NV-C NV400-CW NV630-CW
Earth-leakage circuit breakers

Economy type

NV400-SW
NV-S NV800-SEW
Standard type NV400-SEW NV630-SEW
NV-H
High-performance type NV400-HEW
NV630-HEW NV800-HEW
NV400-REW

NV-U
Ultra current-limiting type
NV-C
Earth-leakage circuit breakers for CE Marking

Economy type
NV400-CW NV630-CW

NV400-SW NV630-SW
NV-S NV800-SEW
Standard type NV400-SEW NV630-SEW
NV-H
High-performance type NV400-HEW
NV630-HEW NV800-HEW
NV400-REW

NV-U
Ultra current-limiting type
Motor-protection

MB
breakers

Motor breaker

List of Product Models - WS-V


Frame (A)
Classification 20 30 32 40 50 60 63 70 100 125 160 225 250
NF-C NF30-CS NF63-CV NF125-CV NF250-CV
Economy class

Moulded Case NF-S NF32-SV NF63-SV


NF125-SV NF125-SGV
NF160-SGV
NF250-SV NF250-SGV
Standard class NF125-SEV NF250-SEV
Circuit Breakers NF-H/L NF63-HV
NF125-HV NF125-LGV NF160-LGV NF250-HV NF250-LGV
High-performance class NF125-HEV NF125-HGV NF160-HGV NF250-HEV NF250-HGV
NF-R/U NF125-RGV NF250-RGV
Ultra current-limiting class NF125-UV NF250-UV
NV-C NV63-CV NV125-CV NV250-CV
Economy class
Earth Leakage NV-S NV125-SV NV250-SV
NV32-SV NV63-SV
Standard class NV125-SEV NV250-SEV
Circuit Breakers NV125-HV NV250-HV
NV-H/R NV63-HV
High-performance class NV125-HEV NV250-HEV

UL listed products

NF-UL NV-UL
Earth-leakage protector
UL489 Listed
UL489 Listed
Moulded-case circuit breaker
Moulded-case circuit breaker

( Detailsuponwillrequest.
be available
)

21
1
Abundant Accessories and Easy Installation

2
22
Intelligent - Measuring & Communicating
‡0'8 0HDVXULQJ'LVSOD\8QLW ZLWK1)$)WKHFLUFXLWEUHDNHUVPHDVXUHDQG
GLVSOD\WKHORDGFXUUHQWOLQHYROWDJHHOHFWULFSRZHUHOHFWULFHQHUJ\
KDUPRQLFFXUUHQWOHDNFXUUHQWDQGSRZHUIDFWRUWRUHDOL]HGHWDLOHG
HQHUJ\FRQWURO7KH\VXSSRUWFXVWRPHUVҋHQHUJ\VDYLQJFRQWURO
‡7KHPHDVXULQJGLVSOD\XQLWFDQEHLQVWDOOHGRQWKHERG\RUSDQHO
‡&RPSDFWZKLWHPHDVXULQJXQLW
‡0HDVXULQJGDWDFDQEHWUDQVPLWWHGWRD3&RUD3/&WKURXJKCC-Link
‡$/$;ZLWKCC-LinkWUDQVPLVVLRQ

23
3
2
24
MCB,
C , RCCB,
CC , Isolator
so o Range
ge

25
5
Distribution Boards

A Perfect Blend of Style & Precision


Mitsubishi Electric’s distribution boards have been specially designed to provide excellent aesthetics
for the interiors of modern day houses and are suitable for all domestic, commercial and industrial
applications.

quality CRCA steel for long lasting strength.

Manufactured with the help of high precision deep drawn tools (no welding involved), and treated
with nine tank phosphating process these distribution boards provide perfect quality and high corro-
sion resistance.

assembly which facilitates easy removale of intermediate player and minimises the assembly time.

SALIENT FEATURES
» Tested in compliance with IEC 61439 - 3 standards from third party and in-house test labs
» IP 43 protection
» Manufactured by deep drawn tools for precise dimensional accuracy, weld free process
» Additional safety for users with help of Shrouded Neutral links, Insulated bus bar and door
earthing
» Reversible and easy mounting of door on either side of the board
» Detachable Din rail assembly (cassette type) for ease in wiring during installation and mainte-
nance
» Excellent aesthetics - Pure white in colour to suit any type of interior walls, high corrosion and
scratch resistance
» Cement protection sheet provided as standard for protection during masonry work

2
26
Metallic Distribution Boards-Range

27
7
2
28
29
9
3
30
New MS-T Magnetic Contactors

10A frame model is Reduce your coil Direct Operation


over 16% smaller inventory by up to from PLC
with a width of just 50%
The MS-T Series' auxiliary contacts
36mm!! from its can operate with load as light as 20V
The new ST series has new wide range 3mA making it suitable for direct
earlier series operating coils which mean 50% fewer control/operation from a PLC output.
variations are required to span the
24-550V voltage range compared to the
There is a saying that "every bit helps" previous SN series. This means a smaller
and now with the industries smallest* stock burden for those users who hold
general purpose Magnetic Contactor in main stock or spare parts.
its class, customers are able to more
easily down-size their boards than ever
before.*based on a survey of 10A frame A tough product for
class Magnetic Contactors conducted
for Mitsubishi Electric September 2012 tough environments
- as standard Smart design means
Slimline Reversing Smart wiring
Tropicalization treatment, anti-corrosion
type treatment and low temperature-response
The integrated terminal covers have an
capabilities are now standard in the S-T
type Magnetic Contactor range, so our DGGLWLRQDO EHQHÀW LQ WKDW WKH\ DFW DV D
The new slimline design has also been customers do not need to worry about JXLGH WR LPSURYH ZLULQJ HIÀFLHQF\ EXW
applied to the mechanical interlocks which version they are ordering.(note also retain the terminal screw in place:
used to create Reversing Magnetic MSO-T and TH-T Magnetic Starters and no mislaying the screw, no dropping it or
&RQWDFWRU FRQÀJXUDWLRQV KHOSLQJ WR thermal overloads have anti-corrosive having trouble reinserting it in to the
save even more switchboard panel treatment only) WHUPLQDO EORFN MXVW IDVW HIÀFLHQW ZLULQJ
space. Fast wiring terminals (model name
with suffix “BC” ) are also available to
IXUWKHU LPSURYH ZLULQJ HIÀFLHQF\
Finger Protection workability and hence productivity.
New integrated
terminal covers MS-T series
The integrated terminal covers offer
YDULRXV EHQHÀWV QRW WR PHQWLRQ DGGHG at a glance
protection against electric shock through
The perennial issues of remembering to VHFXUH ÀQJHU SURWHFWLRQ 7KLV LV DYDLODEOH Power range – 9A- 32A
RUGHU WKH WHUPLQDO FRYHUV ÀWWLQJ WKHP not only on Magnetic Contactors but also Integrated terminal cover
correctly or loosing them in the process Thermal Overload relays, Contactor relays Thermal Overload Relay – TH-T type
are challenges of the past. The and Auxiliary Contact Units. Variants TH- T18
integrated terminal cover system means MS-T Series complies with DIN EN
they are always there, on the Magnetic Range – 0.1…18A
50274/VDE 0660 Teil 514 for
Contactor or its Auxiliary contact, ready TH- T25
)LQJHUVDIH SUHYHQWLRQRIÀQJHUFRQWDFW 
to be used. Range 0.2…26A
Trip Case- 10A
Available with 2 elements & with 3
elements
Reset mode – manual , automatic,
switchable.
Applicable standard –IEC, EN, JIS/CE/UL.
is
al cover
A termin standard
d e d a s
inclu ntactor!
!
in the co

Traditional solution: Cover + Contactor

31
1
New MS-T Magnetic Contactors
Easy branch circuit wiring with Manual Motor Circuit Breaker and
optional connection conductor unit
Easy wiring is available for the new
MS-T Series by using the Manual
Motor Circuit Breaker and optional
connection conductor unit, contributing
your productivity improvement.

he
it e l im inates t
U n
f wires
need o

Higher SCCR value achieved by using with Manual


Motor Circuit Breaker
When the MMP-T Series and the MS-T Series are used together, the higher SCCR (UL short-circuit current rating)
value, can be achieved. That will be a great support for your business in North America.

SCCR
value
increased

3
32
MS-N-Magnetic Contactors

33
3
MS-N-Magnetic Contactors

3
34
35
5
MS-N Overview

3
36
Motor Protection Relays

37
7
Motor Protection Circuit Breaker

3
38
39
9
4
40
Optional Unit

41
1
Electronic Motor Protection Relays

4
42
Solid State Contactors
Series US-K

6.1 Features
Ideal for heavy duty applications Silent operation

The contactor contains no moving parts, so its reliability Since the contactor has no moving part, noise is
and long life are assured even in high cycling eliminated.
applications.

Easy connection

Completely insulated power circuit Up-front wiring.

R S T C1(+)
The power circuit elements are electricaly insulated main circuit control circuit
from the heatsink.
No insulation of the heatsink is required.

U V W C2(–)

Built-in surge absorber


Indicator lamp shows operating condition
Surge absorbers are built-in for protection of the power
circuit elements from line surges.
Front-mounted for clear indication of operational state.

Compact size
OFF state ON state
The contactor consists of a small size body and
heatsink.

43
3
MITSUBISHI ELECTRONIC MULTI-MEASURING INSTRUMENT

EXPAND LINE UP

SUCCEEDED DISPLAY FUNCTIONS

ENHANCED MEASURING FUNCTION

44
4 4
ME96 Super-S Series Features

45
5
4
46
47
7
48
48
Mitsubishi Inverter Series for
HVAC Application Common

49
9
5
50
Mitsubishi Drive Highlighted Point

51
1

You might also like