BLAUBERG Industrial Fans
BLAUBERG Industrial Fans
VENTILATION
220/60
2015-2016
Page 75 of 112
39
ABOUT BLAUBERG Blauberg Ventilatoren is a future- and client-orientated company, which stands
for innovative technology and timeless design for the ventilation industry. With
a great range of the fans and ventilation accessories Blauberg is represented in
more than 20 countries.
We are ready to offer you the most complete product range at the ventilation
market, starting with domestic fans, including accessories for single-room
ventilation with heat recovery and industrial fans and finishing with individually
designed ventilation units and systems.
Page 76 of 112
Due to our product diversity, we do our best to meet the individual needs of our clients in
various countries with the best combination of price and quality.
Our philosophy is to cultivate long-term client relations and partnerships by high quality
and reliability.
Blauberg Ventilatoren always opened for the clients.
You are welcome to visit our attractive show room in the distribution center in Munich
to evaluate the Blauberg program and to review the operating units. Registration at
info@blaubergventilatoren.de
Page 77 of 112
nn
WORLD OF
VENTILATION
4-13
I Ǧƪ
fan Turbo
14-17
nǦna
nfa fan
Iso-B
18-21
nǦna
nfa fan
Iso-V
22-25
26-31
nfa fan
f
ana
Box
32-34
3
Page 79 of 112
WORLD OF VENTILATION
Ventilation means controllable indoor air Oxygen-carbon dioxide rate. We breathe Air humidity. Indoor humidity misbalance
exchange including removal of stale air and in oxygen in and breathe out carbon dioxide. makes it feel uncomfortable and escalates
supply of fresh, normally prepared air to the In enclosed spaces, the oxygen content in the chronic obstructive airway and skin diseases.
premises. air gradually decreases and the carbon dioxide Depending on season and temperature the
Home dust, tobacco smoke, dust mites, increases. No air exchange produces a feeling humidity level also has negative effects on the
household animals, consumer electronics, gas, of stagnation and stale air. No air exchange interior equipment and furniture. For example
finishing materials, carbon dioxide are only a produces a feeling of stagnation and stale air. in winter when air is dry some wooden articles
few sources of indoor air pollution. Healthy life activity requires 21% oxygen content may dry up and humid air provokes swelling of
The absence of proper ventilation may be the in the surrounding environment. To keep the wooden articles and mould formation.
reason of allergic and asthmatic diseases, oxygen concentration on this level the air must Air temperature. The best temperature
spread of infection, attenuation of immunity, be fully exchanged at least once per hour. Some for human wellbeing is between 21 and 23°C.
bad smells and mould in the room. specific applications may require an even higher Any temperature fluctuations or significant
Quality indoor ventilation is the only solution that air exchange rate. deviations with respect from this factor influence
really helps you to prevent the above harmful Maximum Allowable Concentrations of human health, physical and mental activity and
factors. Efficient ventilation is ensured by a Harmful Substances in air. A human being provoke headaches.
number of actions and equipment that arrange breathes in 20 m3 of air every day. Natural air Air motion. Uncontrollable and non-
a working mechanical air exchange in various saturated with ozone, ions and phytoncides is regulated air motion generates air draughts or
ventilation systems. Ventilation systems serve to the most favourable environment for human lack of oxygen. These environments provoke
create a human friendly environment that meets wellbeing. High concentration of dust, gases, respiratory diseases, rapid fatigability, unstable
construction and manufacturing norms as well tobacco and other harmful substances is not blood pressure, etc.
as architectural and storage requirements. only harmful but may lead to various chronic
diseases.
Smell. A lack of balanced air circulation in the
Ventilation is designed to maintain a basic room causes high concentration of long-lasting
healthy environmental quality and a pleasant
smells which create discomfort, provoke allergy
indoor climate for human wellbeing.
reactions and irritate nerves.
The arrangement of an efficient ventilation or air exhaust from limited local areas with supply. It is determined by concentration of
system requires the ability to differentiate high concentration of harmful substances, harmful substances and smells, number of
between various ventilation system types and smells, etc. people, humidity and heat excess in the room.
their application as well as a correct equipment - general exchange ventilation: designed for Every room requires a separate calculation of
selection that matches the specific requirements. supply or exhaust ventilation in a premise. ventilated air based on previous researches or
Design: based on the air exchange rate.
Ventilation systems are classified based - kit ventilation: professionally designed, full Calculation of volumetric air flow accor-
on following parameters: sized ventilation system that is assembled from ding to air exchange rate
Air motion type: various ventilation accessories; Air exchange rate is found experimentally for
- natural (gravity) ventilation: In gravity systems - monoblock ventilation: supply or supply and relatively non-polluted environments.
air is moved due to inner and outer air density exhaust ventilation systems that consist of
and temperature differences without any electric separate components placed inside a relatively V = VR * Aexch/h [m3/h],
equipment (fans, electric motors); small noise- and sound-insulated casing; ready
- artificial (mechanical) ventilation: In mechanical to use ventilation units. VR: room volume, in m3;
systems air is moved by electric and mechanical Aexch: minimum air exchange rate 1/h, see table
equipment and devices (fans, electric motors, Selection of required ventilation equipment is 3, air exchange rate.
filters, air heaters) that provide air moving, the next step for arrangement of a ventilation
cleaning, heating or cooling. system. It is based on the following basic How to determine a room volume?
Purpose: technical parameters: Calculate general volume in m3 with the below
- supply ventilation: provides air supply and - Volumetric air flow [m3/h]. formula:
usually filtering and heating or cooling; - Operating pressure [Pa] and air speed inside
- exhaust ventilation: provides removal of extract air ducts [m/s]. Length x width x height =
of stale air from the room; - Permissible noise level [dB(A)]. volume of a premise [m3]
- air handling unit with heat recovery: efficient - Electric heater power [kW].
controllable ventilation system. Thermal extract A x B x H = V [m3]
air energy is used for warming up or cooling Basic rated technical characteristics for
down the fresh intake air. ventilation equipment selection. Example: The room has 10 m length, 6 m width
Air exchange arranging: Volumetric air flow [m3/h]. and 3.5 m height. To calculate the air volume
- local ventilation: designed for air supply Air volume required for air extract or air required for ventilation of this room first calculate
4
Page 80 of 112
the room volume: 10 х 6 х 3.5 = 210 m3. After that Calculation of volumetric air flow as per Volumetric air flow required to remove
determine the required air capacity for the fan maximum allowable concentrations of heat excess
using the table of recommended air exchange harmful substances in air
rate below. Q
K V= [m3/h]
V= 3
[m /h] ρ * Cp*(tv-tn)
kmax-ka Q : heat emission in the room [kW];
tv: room temperature [°C];
K: amount of pollutants per hour, in mg/h tn: supply air temperature [°C];
kmax: maximum permitted pollutant concentra-
ρ: air density [kg/m3] (at 20°C, ρ = 1,205 kg/m3);
tion, in mg/m3, see table 2 Cp: air heat capacity [kJ/kg*K) at 20°C; Cp=1,005
ka: pollution concentration in supply air, in mg/m3
kJ/kg*K
(clean supply air ka = 0).
Table 3. Air exchange rate:
Table 2. Maximum allowable concentrations of
some substances Premise name Aexch/h
cm3 mg
Substance Living room (flat or 3 m3/h per 1m2 of
m3 m3
hostel) living area
Calculation of volumetric air flow as per Nitric acid 10 25 Kitchen room (flat or
6-8
number of people (DIN 1946 norms, part 2) Ammonia 50 35 hostel)
Domestic premises
In areas with additional pollution sources (e.g. Bathroom 7-9
Aniline 2 8
tobacco smoke), the volumetric air flow per Shower room 7-9
person must be increased by 20 m3/h per person. Asbestos dust – 2 WC 8-10
Acetone 1000 2400 Residential laundry room 7
V = AEP * P [m3/h],
Butane 1000 2350 Dressing room 1,5
Storeroom 1
AEP: air exchange rate per person; Hydrazine 0,1 0,13
P: number of people in the room Garage 4-8
Iodine 0,1 1
- 20-25 m3/h per each person with low physical Cellar 4-6
activity Methanol 200 260 Theatre, cinema halls, 20-40 m3
- 45 m3/h per each person with light physical conference halls per one person
Nicotine 0,07 0,5
activity Office 5-7
- 60 m3/h per each person with heavy physical Ozone 0,1 0,2
Bank 2-4
activity Zinc oxide - 5
Restaurant 8-10
Table 1. Air exchange rate per one person PVC 3 8
Bar, café, beer hall,
depending on premise type (DIN 1946, part 2) 9-11
Propane 1000 1800 billiard room
m3/h per Professional kitchen in
Premise type Mercury 0,01 0,1 10-15
one person café or restaurant
Lecture hall 30 Lead - 0,1 Supermarket 1,5-3
Drugstore (trade area) 3
Big office 60 Formaldehyde 0,1 1,2 Garage and car repair
6-8
Exhibition hall 30 Chlorine 0,5 1,5 shop
Large and industrial premises
5
Page 81 of 112
Operating pressure [Pa] and air speed Recommended air speed in air ducts:
inside the air duct [m/s].
Operating pressure and air speed are calculated
Air speed
based on an air duct design diagram. This Type
[m/s]
diagram is then further worked out as air
distribution network of the ventilation system. Main air ducts 6-8
The required pressure for various ventilation
systems is generated by the fan and is Branches 4-5
calculated on the basis of diameter and length
of the system components, number of bends Air distribution ducts 1,5 - 2
and reducers as well as type of air distribution
Supply ceiling grilles 1–3
devices. The more elements the systems
consists of, the longer the distribution net and Exhaust grilles 1,5 – 3
the more bends and reducers the higher the is
required fan pressure.
Air speed also depends on the air duct diameter. Calculation of air speed in air ducts:
Static pressure created by a fan determines
air motion in the system that has some air V
resistance. Large air duct diameter and high V= (m/s)
air speed increase air resistance and provoke
3600*A
pressure loss. These factors must be considered
while selecting ventilation equipment. V : volumetric air flow [m3/h];
A: air duct cross section area, m2;
6
Page 82 of 112
Electric heater power [kW]. 1. Provide at least minimum required air speed; penetrates into rooms through air distribution
Air heater is used in supply ventilation system devices.
2. Provide air temperature and return water
for heating of supply air during cold seasons. The generated noise level can be reduced by
protection;
Electric heater power is calculated on basis selecting a silent model among other models
3. Provide fan switching off, closing of air with similar technical parameters or by installing
on ventilation system capacity, required
supply air temperature and minimum outdoor damper and opening of regulating damper in silencers.
temperature. Supply air temperature must be case of protection actuation. Ventilation systems are designed with respect to
no less than +18°C. Electric heater power is acoustic calculation aimed at:
calculated as follows: Permissible noise level [dB(A)] z determination of octave band frequency in
The fan itself is the basic noise source. Air flow rated points;
z determination of required reduction of octave
speed also influences the noise level in the
V* ρ* Cp*(tv-tn) ventilation system. band frequency by correlation with permissible
Q= [kW] Noise produced by fans and ventilation system values according to acting norms.
3600 components is spread along air ductworks and
P 50 conversation, typing
I= definitely audible
U 55 Standard for A office premises (EN)
60 Office standard
I: maximum permissible current [A];
65 loud conversation (1 m)
Р: electric heater power [W]; noisy
U: power voltage [V]; 70 several loud conversations (1 m)
The maximum supply air temperature attained 75 shout, laughter (1m)
with the electric heater is calculated as follows:
80 shouting, operating motorcycle with a silencer
3600*Q
Δt = (°С) 85 loud shouting, operating motorcycle with a silencer
V*ρ*Cр 90
very noisy
Loud shouts, freight car (7 m)
3
V: volumetric air flow [m /h] 95 moving subway train (7 m)
ρ: air density [kg/m3]; at 20 °C, Orchestra, subway car (close), thunder
ρ = 1.205 kg/m3 100 Maximum permissible sound pressure for
Cp: air heat capacity [kJ/kg·K], at 20°C, headphones of a personal stereo (according to European norms)
Cp=1,005 kJ/(kg·K)
Q: electric heater power [kW] 105 extremely noisy inside an airplane manufactured before 1980
110 helicopter
The water heater is designed for warming
up air in duct ventilation systems. The heater 115 sandblaster (1 m)
is installed directly into the air duct. Water and
freeze-resistant mixtures are used as heat 120 almost intolerable pneumatic hammer (1 m)
carriers.
130 pain threshold starting air plane
7
Page 83 of 112
FAN TYPES
A fan is a mechanical device designed for air stretched air ducts with high air resistance in the with backward curved blades save up to 20%
transportation along ventilation air ductworks. network. These fans are suitable for mounting electric energy. High overload capability is
Based on design and operating logic the directly on exhaust air ducts. another important advantage.
fans are classified as follows: Smaller impeller diameter, compact fan size,
z axial fans;
lower rotation speed and low noise level are the
z mixed-flow fans (centrifugal and axial);
advantages of radial fans with forward curved
z centrifugal (radial);
blades. Air capacity and pressure characteristics
z tangential (diametral).
are similar to those of the fans with backward
curved blades.
An axial fan consists of a wheel made of Centrifugal fans are used for air supply and
cantilevered blades (impeller) that are fixed exhaust in ventilation systems with stretched air
on the hub at an angle to the rotation level. ducts with high air resistance in the system.
The wheel is located in a cylindrical casing.
Impeller normally is placed directly on the
electric motor axis.
8
Page 84 of 112
These fans are the ideal solution for premises fans may be made of special plastic, galvanized fans are designed for outdoor application
where air needs to be extracted from several steel or combined. Due to compact sizes the and are exposed to weather factors they must
places through a single extract main air inline fans are suitable for installation directly into meet special moisture and dust resistance
duct. Multi-port exhaust fans are used for air ductworks, ventilation and air conditioning requirements. Roof fans are made either of
optimization of air ductwork layout, minimizing systems or suspended behind false ceiling or in high quality steel covered with epoxy corrosion
the need of expensive fittings and are suitable specially designed vertical cabinets. resistant coating or galvanized steel.
for connection with single-type flexible air ducts.
FAN MOTORS
The motors are powered by direct or alternating Asynchronous electric motors consist of simple design and easy operation. The three-
current. two basic components, the stator and the rotor. phase stator winding is inserted inside the slots
A direct current motor is powered by a direct The stator is a fixed motor component. On and consists of a number of interconnected
power supply. the inner side the stator has some slots for coils. Each coil consists of one or several turns
An alternating current motor is powered by an laying of three-phase cable winding that is which are insulated against each other and
alternating power supply. powered by three-phase current. The rotor is against the slot walls.
Alternating current motors are the most widely a rotating part of the motor and also has slots
used motors because the basic electric grid in for inserting the cable winding. The rotor and The asynchronous electric motor with short
the country has alternating power supply. the stator are assembled of separate 0.35 - 0.5 circuit rotor has the following advantages:
mm thick electrotechnical steel pressed plates.
Alternating current motors have two types: Separate plates are insulated from each other z Permanent speed at various loads.
Synchronous electric motors are alternating with a varnish layer. The air gap between the z Resistance to short-term mechanical
current motors with a rotor that rotates synchro- stator and the rotor is kept as low as possible: overloads.
nously with a magnetic field; 0.3 - 0.35 mm for low capacity machinery and z Easy structure.
Asynchronous electric motors are alternating 1-1.5 for more powerful machinery. Depending z Easy start-up.
current motors with the magnetic field frequency on the rotor design the asynchronous motors z Higher cos φ and efficiency compared to
exceeding the motor rotation speed. are available in short circuit modification and electric motors with phased rotor.
Nowadays the asynchronous electric motors phased modifications. Short circuit motors are
find wide application. the most widely used motors because of their
9
Page 85 of 112
The design of the asynchronous electric Advantages of the asynchronous electric for fans integrated into a single network.
motor with external rotor is similar to that of motor with external rotor: Parameters of a single fan integrated into a
the standard asynchronous electric motor. z Long service life. common network may be centrally corrected
The only difference is the position of the rotor. z Light weight and small overall dimensions. to match the ventilation system parameters. All
The electric rotor motor is located inside the z Easy assembly and installation. the system parameters are displayed online on a
stator winding and the stator with turns is located z Aligned impeller and electric motor. computer. This enables programming individual
in the electric motor center. This configuration z Regulated air capacity. operation modes of each fan in the system. This
provides a compact size of the ventilation z Low energy demand during start-up. technology enables also programming custom-
unit. The electric motor shaft is carried by ball made settings to meet individual customer
bearings fixed inside the stator and the impeller The electric motor with high-efficient requirements.
is fixed in the rotor casing. Such a design EC motor is a synchronous direct current
motor driven by an electronic commutating unit Advantages of EC motors:
(controller). It has no friction and wearing parts z Efficient performance at any rotation speed
as a collector or brushes, unlike the standard of the fan, including very low speed.
motor. The function of these parts is performed z Low heat emission.
with the maintenance-free electronic circuit of z Small overall dimensions of the unit due to
the EC controller. external rotor design.
The EC technology is the state-of-the-art z Maximum fan rotation speed does not
method for arrangement of energy saving and depend on frequency in the grid. The fan is
high efficient ventilation. The energy demand suitable for connection both to 50 Hz and
of EC motors is by 50% less as compared to 60 Hz power mains.
standard motors and efficiency reaches 90%. z High efficiency at low rotation speed.
These new electric motors are featured with high z Energy demand is by 1/3 less as compared
performance, low noise level and controllable to standard motors.
total speed range. The electronic EC-controller z Data interchange between PC and fan for
enables some other smart functions, e.g. fan parameter setting and control.
control according to measured temperature, z Integration of all fans into a unified system
pressure and other parameters. and their centralized control.
A unique software ensures high control accuracy
10
Page 86 of 112
FAN SPEED CONTROL
The need to control speed, i.e. regulate fan speed control. This results in significant Transformer control.
air capacity in the ventilation system arises due noise level reduction. The noise level is Transformer controllers are designed for
to fluctuations of heat emission, concentration calculated as follows: speed control of voltage controlled motors by
of harmful substances, humidity level, etc. altering the voltage supplied (five units). The
Fan speed control is required for systems with (n) operation of transformer speed controllers is
variable air exchange and is performed with a L ≈ 50 Lg dB based on the use of five-stage autotransformers
n0
speed controller. for regulation of the motor power voltage.
All the motors have a 100% controllable speed (n0: Rated speed) Frequency in the grid remains the on the same
range by transformer and electronic devices. The level. Several fans may be controlled by a
explosion-proof motors are controlled exclusively single controller if the total fan current does
by transformers from 25% up to 100% of the L: power / sound volume [dB(A)] not exceed the rated controller current. In case
rated voltage. Speed control is performed due to Conformity to the fan operation conditions of a transformer speed controller application
voltage change whereas the frequency in the grid and technical parameters (air quality the motor does not generate increased noise
remains the same. The electric motor speed is deterioration, humidity increase, variable in the lower speed range. The bearings in low
smoothly decreased as power voltage drops or is number of people, etc.). voltage motors have shorter service life. The
increased as power voltage rises. The motor can Depending on the controller type the fans recommended voltage control range is up to
also be controlled with a frequency converter. have the following air capacity controls: 45% of the rated frequency value for single-
- Thyristor control. phased motors and up to 55% of the rated
Power regulation of ventilation units and - Transformer control. frequency value for three-phased motors.
speed control respectively provides the - Frequency control.
following benefits: The thyristor controllers are designed Frequency control.
Comfortable fan capacity mode. for smooth manual regulation of the fan speed Frequency controllers are designed for
Energy saving operation mode. and accordingly the air capacity. They are used smooth start-up or speeding down, speed
The rotation speed control as a way of regulating for fans with asynchronous electric motors altering, regulation of air capacity and protection
the fan air capacity is one of the most efficient and are featured with high control accuracy of asynchronous electric motors due to
solutions to increase the fan performance. and efficiency. Operating supply voltage 230 V generation of a required frequency at the outlet
The fan power consumption drops in direct (~1, 50Hz). Several fans may be controlled by of the voltage converter. The converter consists
proportion to rotation speed in third power: a single controller if the total fan current does of an electric drive and a control component.
not exceed the rated controller current. The The electric drive of the frequency converter
speed controller provides smooth air capacity consists of separate control circuits comprising
PL ( n )3 regulation from 0 to 100%. In case of low speed a thyristor or a transistor that operate in
= electronic key mode. A microprocessor is the
PL,0 n0 operation the fan may produce increased noise.
For that reason a thyristor speed controller is core of the control component. It provides
used for ventilation systems with no special control of power electronic keys and has many
Р: electric power [W, kW]. requirements to the noise level. The bearings in other supplementary functions, i.e. control,
The amount of saved power depends on perfor- low voltage motors have a shorter service life. diagnostics, protection.
mance data of the motor and the control unit. The recommended control speed range for the
thyristor speed controllers is from 60 to 100% of
Noise level decrease. rated voltage.
The fan parameters match optimally during the
11
Page 87 of 112
IP CODE SYSTEM
When selecting the required equipment and de- against environmental impact. mechanical objects and touch to live parts and
termining its location the equipment's ingress The degree of mechanical protection provided the second digit shows protection against liquid
protection rating must match the operating by casings of electric appliances is classified penetration. Each product has a respective
conditions. Any electric appliance must always according to international dust- and humidity- marking on the casing, i.e. IPX4 or IP65.
meet two protection demands: protection standard "International Protection"
z electric safety for the user and service ("Internal protection") and is marked with the Characteristics of ingress protection are shown
personnel; letters "IP" followed by two digits. The first digit in tables 5 and 6.
z protection of the inner electronic components shows protection degree against penetration of
Table 5. Protection rating against penetration of solid particles and touch to live parts.
х No special protection Open design, no protection from dust and touch to live parts.
Protection from OBJECTS EQUAL TO OR GREATER THAN 50 mm and accidental hand touch to live
1 Protection from large objects
parts.
2 Protection from medium objects Protection from OBJECTS EQUAL TO OR GREATER THAN 12 mm and fingers touch to live parts.
3 Protection from small objects Protection from OBJECTS EQUAL TO OR GREATER THAN 2,5 mm and entry by tools, wires or fingers.
4 Protection from sand Protection from OBJECTS EQUAL TO OR GREATER THAN 1 mm and entry by tools, wires or fingers.
Minor quantities of dust can penetrate the casing which does not disturb the rated operation. Full
5 Protection from dust
protection against touch to current-carrying parts.
Protection against complete, The equipment is suitable for continuous immersion in water under conditions which shall be specified
8
continuous submersion in water by the manufacturer.
12
Page 88 of 112
GENERAL INFORMATION
BLAUBERG ventilation products are featured with Data on voltage, frequency, current, rated efficiency both for permanent and controllable
traditional German quality and high technology. motor power, ingress protection and electric speed mode.
Since many years BLAUBERG preserves a connection recommendations are stated in
flawless reputation that is acknowledged by the technical parameters for each product. The casings used for enclosure of the
worldwide experts. The stated data meet standard operating BLAUBERG ventilation units are made of plastic,
The BLAUBERG production facilities allow to requirements under air density p = 1.2 kg/m3, aluzinc, aluminium or steel. Depending on the
manufacture the complete ventilation product temperature T = 20 °C and power frequency model type the casing may have a polymeric
range and ensure full matching and compatibility 50 Hz. Follow the manufacturer's data on a coating, weather resistant coating or a thermal-
of all the turn-key ventilation system components. priority basis while connecting the equipment and sound insulation of mineral wool. Depending
Ongoing implementation of new technologies to power mains. Depending on operating and on application the ventilation units may be
and innovative solutions lead BLAUBERG environmental conditions some deviations are equipped with electric heaters or water heaters
products to a state-of-the-art and popular level. possible within permissible limits. with integrated overheating thermostats, units
for energy recovery (recuperators), filters of
BLAUBERG products main advantages: Connect the unit to power mains with required purification class and by-pass ducts
z reliability; respect to the wiring diagram stated in the and dampers. All the appliances have fixing
z high quality; operation manual and valid electrical codes. elements for easy mounting and hinged panels
z state-of-the-art; The motor is protected against overload and for easy servicing.
z innovative; phase loss by emergency shutdown, overheat
z fully equipped; thermostats or full safety protection devices on The warranty period for BLAUBERG
z easy maintenance. each contact and in every rotation speed range. equipment is 12 months from delivery date. The
The selection of the emergency switch must be warranty scope is stated in the delivery terms.
Read the user manual carefully before in compliance with manufacturer's guidelines. Unauthorized design modification, disregard of
operating any BLAUBERG products. Be sure Failure to comply with the manufacturing installation and connection recommendations
that the operating mode and environmental requirements may result in equipment will void all manufacturer's warranty obligations.
conditions match the equipment parameters. Do malfunction and void the manufacturer warranty.
not operate the equipment if it does not match The present product catalogue is a
the required operating conditions because it Standard fans are designed for operation promotional material. BLAUBERG Company
violates safety requirements. in moderately polluted and humid-laden reserves all the rights to modify the present
environments without aggressive substances. catalogue.
The BLAUBERG fans are equipped with The operating temperature range is from -30°C
various motors, including synchronous and up to +40°C. Contact the manufacturer and be
asynchronous motors, AC, DC and EC motors. advised prior to use of ventilation equipment in
All the motors are durable and reliable, fitted any specific environment that does not meet the
with thermostats for overheating protection and standard requirements.
distinguished by efficient operation and low noise
level. The motors are made of aluminium or cast BLAUBERG thyristor and transformer speed
iron, they are fully enclosed and have a suitable controllers are used for fan power regulation.
ingress protection. The BLAUBERG motor parameters match
the impeller parameters to provide maximum
CERTIFICATION
Various series of the products are marked with the following check symbols:
Mark of conformity to the European Quality Standards and Mark of conformity of the products liable to obligatory certification
electrical safety issued by Association for Technical Inspection in the DSTR system as well as acting technical norms and standards
(Technischer Überwachungsverein, Germany). in the Russian Federation.
13
Page 89 of 112
Inn Ǧƪ fan
T
A
aa
Ȃ ͙͘͟͝ 3/h
Use
Supply and exhaust ventilation systems installed in various premises.
Mounting in kitchens, bathrooms and other humid premises.
Ventilation air ducts requiring high pressure, powerful air flow and low noise level.
Compatible with Ø100 up to 315 mm round air ducts.
Design ТD – mounting kit for installation of one diameter fans in parallel (for
Casing made of low-flammable polypropylene. boosting capacity)
Ventilation unit with terminal box. Can be turned to any position.
Special casing design permits easy dismantling of the impeller and
motor block for fan servicing without dismantling the air duct .
Motor
Double-speed single-phase motor on ball bearings.
Equipped with thermal overload protection.
Speed control
The built-in switch (option US) or external switch for multi-speed TL – mounting kit for installation of one diameter fans in series (for
fans (available upon separate order) are used to select one of two boosting pressure).
capacity modes.
Smooth speed control is possible with a built-in speed controller
(option FR) or an external thyristor speed controller (available upon
separate order).
Mounting
Due to compact design the fan is the ideal solution for mounting in
limited spaces, including space behind a false ceiling.
The fan can be installed in any section of the ventilation system from
intake to the end of the ductworks.
Wall or ceiling mounting with a mounting plate.
14
Page 90 of 112
Modifications and options supplied with a pre-wired power cable with IEC plug as a standard.
T – adjustable run-out timer regulated from 2 to 30 minutes. The cable modification with a standard electric plug is also available (G1).
US – three-position speed switch integrated in the fan.
FR – built-in smooth speed controller from 0 to 100%. The fan is sup-
plied with a pre-wired power cable with IEC plug as a standard. The cable
modification with a standard electric plug is also available (FR1).
Overall dimensions
15
Page 91 of 112
Specifications
Turbo 150
Parameters Turbo 100 Turbo 125
Turbo 160
Speed min max min max min max
Voltage [V / 50 /60 Hz] 1~ 230 1~ 230 1~ 230
Power [W] 23 25 25 30 42 50
Current [A] 0,10 0,11 0,11 0,13 0,19 0,22
Maximum air capacity [m3/h] 170 220 230 345 430 560
-1
RPM [min ] 1980 2545 1535 2265 1940 2620
Sound pressure level at 3 m distance [dBA] 27 32 29 34 37 46
о
Max. operating temperature [ С] 60 60 60
Ingress protection rating IP X4 IP X4 IP X4
Pressure [Pa]
Pressure [Pa]
160
140
140
Turbo 100 Turbo 125
120
120
100
100 max
80
80
max
60
60
min
40
40 min
20 20
0 0
0 40 80 120 160 200 0 50 100 150 200 250 300 350
Turbo 150
250
Turbo 160
200
max
150
100
min
50
0
0 100 200 300 400 500 600
16
Page 92 of 112
Specifications
Pressure [Pa]
350 500
Turbo 200
300 Turbo 250
400
250
300
200
max max
150
200
100
min min
100
50
0 0
0 200 400 600 800 1000 0 200 400 600 800 1000 1200 1400
600
Turbo 315
500
400
300 max
200
min
100
0
0 400 800 1200 1600
17
Page 93 of 112
nǦna
nfa fan
IǦ
A
aa
Ȃ ͚͙͘͝ 3/h
Use
Supply and exhaust ventilation systems installed in premises with high requirements to the noise level.
Compatible with Ø100 up to 315 mm round air ducts.
Suitable for limited mounting space.
Design Mounting
Galvanized steel casing internally filled with 30 mm thermal- and Mounting in any position.
sound-insulating layer made of non-flammable foamed polyurethane. Fixed to wall or ceiling with a fixing bracket supplied as a standard.
Connecting spigots are equipped with rubber seals. Flexible air ducts are fixed on fan spigots with clamps.
Fixing brackets for easy mounting. Power is supplied through an external terminal box
18
Page 94 of 112
Overall dimensions
Dimensions [mm]
Type Weight [kg]
D B B1 H L L1 L2
Iso-B 100 99 322 280 192 447 380 350 5,4
Iso-B 125 124 322 280 192 447 380 350 5,4
Iso-B 150 149 352 310 212 477 410 380 6,4
Iso-B 160 159 352 310 212 477 410 380 6,4
Iso-B 200 199 432 368 287 588 506 480 10,0
Iso-B 200 max 199 432 368 287 588 506 480 12,0
Iso-B 250 249 432 368 287 588 506 480 12,5
Iso-B 315 314 502 438 397 648 566 540 15,5
19
Page 95 of 112
Specifications
Parameters Iso-B 100 Iso-B 125 Iso-B 150 Iso-B 160
Voltage [V / 60 Hz] 220-240 220-240 220-240 220-240
Power [W] 77 77 77 77
Current [A] 0.34 0.34 0.34 0.34
Maximum air capacity [m3/h] 255 345 345 345
RPM [min-1] 2690 2700 2700 2700
Sound pressure level at 3 m distance [dBA] 34 36 36 36
Max. operating temperature [оС] -25 +55 -25 +55 -25 +55 -25 +55
Ingress protection rating IP X4 IP X4 IP X4 IP X4
Pressure [Pa]
Pressure [Pa]
Power [W]
Pressure [Pa]
Power [W]
20
Page 96 of 112
Specifications
Parameters Iso-B 200 Iso-B 200 max Iso-B 250 Iso-B 315
Voltage [V / 60 Hz] 220-240 220-240 220-240 220-240
Power [W] 122 232 238 367
Current [A] 0.53 1.02 1.04 1.6
Maximum air capacity [m /h] 3 750 960 1315 2150
RPM [min-1] 2740 2690 2730 2850
Sound pressure level at 3 m distance [dBA] 39 42 43 44
Max. operating temperature [ С] о -25 +45 -25 +45 -25 +45 -25 +45
Ingress protection rating IP X4 IP X4 IP X4 IP X4
Pressure [Pa]
Pressure [Pa]
Power [W]
120 230
210
110
190
100
170
90 150
Pressure [Pa]
600
500
400
300
200
100
0
0 200 400 600 800 1000 1200 1400
Air capacity [m3/h] Air capacity [m3/h]
Power [W]
Power [W]
250
230 380
210
190 320
170
150 260
0 200 400 600 800 1000 1200 1400
21
Page 97 of 112
nǦna
nfa fan
IǦV
A
aa
Ȃ ͜3͙͘ 3/h
Use
Supply and exhaust ventilation systems installed in premises with high requirements to the noise level.
Various application possibilities due to a special transformable casing design.
Suitable for use as separate components of air handling systems.
Compatible with Ø355 up to 710 mm round or 500x500 up to 1000x1000 mm rectangular air ducts.
Iso-V EC fan with vibration- Iso-V EC fan with connecting Iso-V fans with Iso-V fans with RSD-IV
absorbing flexible connectors reducers ARV series AH-IV outer hood protecting cover
AKV series
22
Page 98 of 112
Fan and accessories overall dimensions
Dimen-
Options
sions [mm] Weight
Type AKV vibration RSD-IV
[kg] ARV connector- AH-V outer
A absorbing con- protecting
reducer hood
nector cover
RSD-IV AН-IV
Iso-V 355 4D 500 25 ARV 355 AKV 500
315-355 315-355
Iso-V 400 4Е 670 39 RSD-IV AН-IV
ARV 400 AKV 670
Iso-V 400 4D 670 39 400-500 400-500
Iso-V
Dimensions [mm]
Type
A B D
ARV 355 490 470 355
ARV 400 660 640 400
ARV
Dimensions [mm]
Type
A B C
AKV 500 490 470 445
AKV 670 660 640 615
AKV
Dimensions [mm]
Type Weight [kg]
B
A B H
AH-IV 315-355 478 458 225 3,2
AH-IV 400-500 648 628 321 6
H
AH-IV
Dimensions [mm]
Type Weight [kg]
A
RSD-IV 315-355 600 2,3
RSD-IV 400-500 770 4,65
RSD-IV
23
Page 99 of 112
Specifications
Parameters Iso-V 355 4D Iso-V 400 4Е Iso-V 400 4D
Voltage [V /60 Hz] 3~ 400 1~ 230 3~ 400 U 3~ 400 Y
Power [W] 235 700 750 515
Current [A] 0.53 3.15 1.44 0.93
Max. air flow at air flow direction [m3/h]:
– perpendicular air flow 2815 4310 4310 3525
– direct air flow 2580 4015 4055 3290
RPM [min-1] 1600 1460 1610 1220
Sound pressure level at 3 m distance [dBA] 55 52 53 49
Max. operating temperature [°С] -25 +65 -40 +55 -40 +60 -40 +40
Ingress protection rating IP X4 IP X4 IP X4
Pressure [Pa]
Pressure [Pa]
230
220
210
24
Page 100 of 112
Aa a fan
AǦ
A
aa
Ȃ ͙͚͚͘͘ 3/h
Use
Supply and exhaust ventilation systems installed in various premises.
Ideal solution for boosting large air volumes at low aerodynamic resistance in the ventilation system.
Refrigerating technologies for cooling of compressor condensing units.
Direct air exhaust.
For positive pressure ventilation in fire-fighting systems.
26
Page 102 of 112
Overall dimensions
Dimensions [mm]
Type Weight [kg]
D d B B1 L
Axis-Q 200 2Е 210 7 312 260 145 3,95
Axis-Q 250 2Е 260 7 370 320 155 4,17
Axis-Q 250 4Е 260 7 370 320 155 4,06
Axis-Q 300 2Е 326 9 430 380 195 5,27
Axis-Q 300 4Е 326 9 430 380 195 5,11
Axis-Q 350 4Е 388 9 485 435 200 7,05
Axis-Q 400 4Е 417 9 540 490 240 8,80
Axis-Q 450 4Е 465 11 576 535 250 10,50
Axis-Q 500 4Е 520 11 655 615 260 14,15
Axis-Q 550 4Е 570 11 725 675 280 16,50
Axis-Q 630 4Е 650 11 800 710 295 22,55
Axis-Q 250 2D 260 7 370 320 155 4,17
Axis-Q 250 4D 260 7 370 320 155 4,06
Axis-Q 300 2D 326 9 430 380 155 5,27
Axis-Q 300 4D 326 9 430 380 155 5,11
Axis-Q 350 4D 388 9 485 435 200 7,05
Axis-Q 400 4D 417 9 540 490 240 8,80
Axis-Q 450 4D 465 11 576 535 250 10,50
Axis-Q 500 4D 520 11 655 615 260 14,2
Axis-Q 550 4D 580 11 725 675 260 16,6
Axis-Q 630 4D 650 11 800 710 295 22,6
Axis-Q 630 6E 650 11 800 710 295 22,6
27
Page 103 of 112
Specifications
Axis-Q 250 4E
Axis-Q 300 2E
Axis-Q 300 4E
Axis-Q 300 4E
LwA to environment, [dBA] 67 58 57 59 57 58 53 52 49
28
Page 104 of 112
Specifications
Pressure [Pa]
Axis-Q 500 4E
Axis-Q 400 2E
Axis-Q 450 4E
Axis-Q 350 4E
Pressure [Pa]
Axis-Q 630 4E
Axis-Q 550 4E
29
Page 105 of 112
Specifications
Pressure [Pa]
Axis-Q 400 4D
LwA to environment, [dBA] 75 65 66 69 66 67 64 60 55
30
Page 106 of 112
Specifications
Pressure [Pa]
31
Page 107 of 112
nfa fan
f
ana
A
aa
Ȃ 3͙͝͝ 3/h
Use
Supply and exhaust ventilation systems installed in various premises.
Compatible with 400x200 up to 600x350 mm rectangular air ducts.
Overall dimensions
32
Page 108 of 112
Specifications
Box 50x30 Box 50x30 Box 60x30 Box 60x35 Box 60x35
Parameters
4E 4D 4D 4E 4D
Voltage [V / 60 Hz] 220-240 3~ 400 3~ 400 220-240 3~ 400 U 3~ 400 Y
Power [W] 175 165 220 700 750 515
Current [A] 0.73 0.53 0.9 3.15 1.44 0.93
Maximum air capacity [m3/h] 1855 1620 2470 3515 3410 2730
RPM [min-1] 1530 1600 1400 1460 1610 1220
Sound pressure level at 3 m distance [dBA] 55 55 55 68 64 63
о
Max. operating temperature [ С] -25 +50 -25 +55 -25 +45 -40 +55 -40 +60 -40 +40
Ingress protection rating IPX4 IPX4 IPX4 IPX4 IPX4
Pressure [Pa]
Pressure [Pa]
33
Page 109 of 112
Pressure [Pa]
Pressure [Pa]
Air capacity [m3/h] Air capacity [m3/h]
Power [W]
Power [W]
34
Page 110 of 112
Centrifugal roof fan
Tower-H
Air capacity – up to 4700 m3/h
Use
Exhaust ventilation systems installed in various premises.
Roof mounting.
For any types of roofs or vertical ventilation shafts.
Overall dimensions
Pressure [Pa]
Pressure [Pa]
123
Page 114 of 116
Specifications
Pressure [Pa]
Pressure [Pa]
124
Page 115 of 116
Specifications
Pressure [Pa]
Pressure [Pa]
info@blaubergventilatoren.de
www.blaubergventilatoren.de
05/2015
38
Page 112 of 116