Service Manual: Model:FF2-69

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 22

Service manual

Model:FF2-69

Contents

1 Cover

2 The cooling system

3 The electrical diagram

4 Trouble shooting guide

5 Exploded view

6 Spare part list

# Classified as Internal
The cooling system

# Classified as Internal
# Classified as Internal
The electrical diagram

# Classified as Internal
# Classified as Internal
Trouble shooting guide
No Problem Possible Cause What To Do

open the cover board of air duct in


freezer room, check the fan if it no
running, then measure the voltage
the the fan motor is failure and replace it
between the red wire and black wire
with a new one
of fan, if the voltage is 12V,the the
fan motor is failure and replace it
Fan no work,Freezer room with a new one
temperature no enough cold
and refrigerator room
1 measure the voltage between the
temperature Ok and
compressor running, but no the failure of the inner wire to fan CN2 red and black wire of PCB, if
air in freezer air outlet. connector the voltage is 12V, then check from
the inner wire to fan connector

measure the voltage between the


CN2 red and black wire of PCB,if the
the PCB failure and change a new PCB
voltage is zero, then the PCB failure
and change a new PCB.

disconnect power, and let the ice


defrost and inspect the water if it is
the drainpipe contain impurity flow through the drainpipe, if could
not flow out, check if it contain
impurity and clean the drainpipe
No defrost.Freezer room
temperature no enough cold
and refrigerator room OK check the fuse if it is melt or not. If
2 the fuse is melt, it mean that the
and open the cover board of the sensor failure or PCB failure
are duct and find ice sensor failure or PCB failure, need
formation on evaporator change the sensor or PCB.

inspecting the CN4 defrost heater


two connector.If the heater is OK
the defrost heater is break or PCB failure
then it must be PCB failure and
change the PCB.
inspect the potentiometer
(thermostat), and measure the
resistance value by adjusting the
the potentiometer failure potentiometer (thermostat), if the
resistance value no change by
adjusting the potentiometer
(thermostat),

When the sensor failure and the


the temperature of freezer compressor will be running like this
and refrigerator are no —if the potentiometer (thermostat)
enough cold and the setting below 3 position, the
3
temperature no change by compressor will be running 20
adjusting the potentiometer minutes and then stop 30 minutes, if
(thermostat) the potentiometer (thermostat) setting
the sensor failure more than 3 position, the compressor
Classified as Internal
will be running 30 minutes and then
#

stop 20 minutes. If find the


When the sensor failure and the
the temperature of freezer compressor will be running like this
and refrigerator are no —if the potentiometer (thermostat)
enough cold and the setting below 3 position, the
3
temperature no change by compressor will be running 20
adjusting the potentiometer minutes and then stop 30 minutes, if
(thermostat) the potentiometer (thermostat) setting
the sensor failure more than 3 position, the compressor
will be running 30 minutes and then
stop 20 minutes. If find the
compressor work like above
situation, it mean the sensor failure
and need open the back of
refrigerator and change sensor of
refrigerator evaporator

Open the refrigerator door and


measure the voltage of CN3 in PCB,
if the voltage is zero then it mean the
the led failure
connecting wire failure and if the
voltage is 12V, it mean the led
failure
4 LED no light
If the CN3 voltage no 12 V and then
check the CN4 voltage, if the voltage
the switch circuit is failure CN4 no change by close and pen
door, it mean the switch circuit is
failure.

the time between two starting is


shorter than 12min; or refrigerator
room temperature is lower than the
no problem
setting temperature, in this case, it is
no problem. You need waiting more
time.

PCB had automatic self-examination:


open the cover of PCB at the back of
product, plug in power and push the
SW101 switch 3 seconds and the
PCB begin automatic self-
examination program, then the led
5 Compressor no starting and compressor and fan and defrost
PCB failure heater all work two second and then
stop, all wore one time and then quit
automatic self-examination program,
and the program will return the
original setting. If the automatic self-
examination program no work, it
mean the PCB failure and need
change it

# Classified as Internal
measure the voltage of compressor
input connector, if it is OK then
ompressor wire not right or compressor
check the starting and relay of
damage
compressor, also check the wire if it
is OK

check the power by multimeter, if


the input voltage is 220V-240, but
the led, compressor, fan, defrost
6 product no any work the PCB failure
heater are all no work, it mean the
PCB failure and need change a new
PCB

# Classified as Internal
# Classified as Internal
# Classified as Internal
# Classified as Internal
# Classified as Internal
# Classified as Internal
# Classified as Internal
# Classified as Internal
# Classified as Internal
FF2-69 (ERSO52B3HUS)Parts list
No. Homa code Description of Spare Part Quantity

2 2107150009 Adjustable foot assembly 2

3 2208510094 Door aid-closer,right 1

4 2301400089 Lower door hinge assembly,left 1

5 2208510095 Door aid-closer,left 1

8 2301400088 Lower door hinge assembly,right 1

9 2501100018 Damper motor of refrigerator wind 1

10 2800100113 Seal sponge of damper motor 1

11 2701000348 Fixation foam of damper motor 1

12 20122990629 Thermal head cover 1

13 2208101322 Decorative cover of refrigerator wind tunnel parts 1

14 2208100776 Decorative link of refrigerator wind tunnel parts 1

15 2208500160 Front cover of refrigerator wind tunnel parts 1

16 2701000346 Front foam of refrigerator wind tunnel parts 1

17 2701000347 Rear foam of refrigerator wind tunnel parts 1

18 2208500161 Thin film of refrigerator wind tunnel parts 1

19 2800100102 Inner seal sponge of refrigerator wind tunnel parts 1

23 2106161138 Upper drawer 1

24 2106161139 Lower drawer 1

28 2106100643 Shelf of freezer chamber,upper 3

29 2106100384 Shelf of freezer chamber,middle 1

30 2106100644 Shelf of freezer chamber,lower 1

32 2107160034 Rjght guide 2

33 2107160033 Left guide 2

34 2106120572 Cover of crisper drawer 4

35 2106120379 Cover of crisper drawer 1

36 2207501330 Door rack,right 4

38 2106141552 Crisper drawer,upper 1

39 3039900184 Limit line iron 2

41 2106141553 Crisper drawer,lower 1

# Classified as Internal
42 2200200137 Door gasket,right 1

43 2100250311 Door,right 1

44 20122990493 Screw cap 1

45 2208500163 Front cover of freezer wind parts,upper 1

46 2800100103 Seal sponge of upper cover 1

47 2501000015 Fan motor parts with fan 1

48 2208500048 Front cover of Freezer wind parts,lower 1

49 3080100058 Seal sponge of lower cover 1

50 2208500162 Upper bracket of freezer wind parts 1

51 2800100104 Seal sponge of outlet wind parts 1

52 2208101323 Decorative cover of refrigerator wind tunnel parts 1

53 2208100776 Decorative link of refrigerator wind tunnel parts 1

54 2106808631 Handle handle,Left 1

55 2106808631 Handle handle,Right 1

56 2207700086 Compressor cover assembly 1

60 2208100963 Cover of ceiling light 2

61 2500400015 Ceiling light 2

62 2208100432 Cover of right hinge,upper 1

63 3031400215 Upper door hinge assembly,right 1

64 3031400214 Upper door hinge assembly,left 1

65 2208100431 Cover of left hinge,upper 1

67 2500300235 Control board 1

68 2305700071 Cover of control board 1

70 2207501328 Freeze on the shelf 1

71 2207501329 Freeze shelf 3

72 2200200138 Door gasket,left 1

73 2100250310 Door,left 1

75 2500300227 Display circuit board 1

76 2209100300 Display panel 1

78 2207700087 Drain pan 1

79 2402400019 Evaporative condenser 1

80 3020600065 Drain pipe 1

# Classified as Internal
82 2107100005 Compressor base support 1

83 2500100128 Power supply cord plug 1

85 20114070006 Connecting tube 1

86 3040500022 Drier filter 1

87 2400100198 Compressor assembly 1

92 3040600005 Process tube 1

93 2501100039 Temperature sensor 1

94 3040300056 Fin Evaperator 1

95 2500700049 Frost heater & fuse 1

97 3039900181 Fixed slot of heater 1

99 2501100017 Door switch 2

101 20120080169 Ice-making box assembly 1

300 2700500204 Trademark 1

301 2700115397 Carton 1


Totally Quantity:
Total Amount:

# Classified as Internal
S)Parts list
Unit price Chinese Name

0.90 调节脚部件

0.40 右门助吸器

4.25 左下门铰部件

0.40 左门助吸器

4.25 右下门铰部件

11.71 电动风门

0.12 电动风门密封海绵

0.18 风门固定泡沫

0.21 感温头罩

1.07 冷藏风道装饰盖

2.30 冷藏风道装饰环

3.40 冷藏室风道盖板

2.48 冷藏风道前泡沫

0.77 冷藏风道后泡沫

3.04 冷藏风道复合薄膜

0.20 冷藏风道进风口密封海绵

7.54 上抽屉部件

7.92 下抽屉部件

3.81 冷冻上层架部件

3.94 上抽屉盖部件

4.00 上抽屉盖部件

0.73 右小导轨部件

0.73 左小导轨部件

5.16 果菜箱盖部件(丝印)

5.10 果菜箱盖部件

4.08 冷藏搁架

10.22 上果菜箱部件

1.07 限位衬铁

10.11 下果菜箱部件

# Classified as Internal
10.72 右门封

61.60 右门

0.21 螺钉盖帽

6.07 冷冻风道上盖板

1.31 上盖板密封PE海绵

16.54 直流离心风扇电机部件

6.48 冷冻风道下盖板

3.70 下盖板密封PE海绵

5.95 冷冻风道上支架

0.29 冻风道出风口密封海绵

1.07 冷藏风道装饰盖

2.30 冷藏风道装饰环

31.93 左门外置拉手

31.93 右门外置拉手

7.13 压缩机后罩

0.73 吸顶灯罩

2.78 LED灯板

1.51 右上门铰盖

3.11 右上门铰部件

3.11 左上门铰部件

1.00 左上门铰盖

26.34 主控板

3.17 主控板盖

2.45 冷冻上搁架

2.55 冷冻下搁架

10.21 左门门封

66.58 左门

28.74 显示板

9.75 显示操作面板

3.12 接水盘

3.59 蒸发式冷凝器

0.88 排水管

# Classified as Internal
15.60 压缩机托板组件

7.90 电源线

1.78 回气连接管

3.84 干燥过滤器

67.31 压缩机

1.34 封尾管

3.11 感温头部件

31.01 翅片蒸发器

14.63 化霜加热器

3.85 加热器接水槽

2.19 门开关

9.64 制冰盒部件

4.59 商标

20.90 纸箱
PCS
Total Amount:

# Classified as Internal