ANChor Design

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

Hilti PROFIS Engineering 3.0.

70

www.hilti.in
Company: Page: 1
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Jul 7, 2021 Date: 07/07/2021
Fastening point:

Specifier's comments:

1 Anchor Design
1.1 Input data

Anchor type and diameter: HSA M12 hnom3


Return period (service life in years): 50
Item number: 2004157 HSA M12x145 65/50/15
Effective embedment depth: hef = 100.0 mm, hnom = 114.0 mm
Material:
Evaluation Service Report: ETA 11/0374
Issued I Valid: 22/10/2020 | -
Proof: Design Method ETAG (No. 001 Annex C/2010)
Stand-off installation: eb = 0.0 mm (no stand-off); t = 12.0 mm

Anchor plate
CBFEM
: lx x ly x t = 250.0 mm x 250.0 mm x 12.0 mm;

Profile: Rectangular Hollow Sections India, 122x61x5.4; (L x W x T) = 122.0 mm x 61.0 mm x 5.4 mm


Base material: uncracked concrete, M 35, fc,cube = 35.00 N/mm ; h = 250.0 mm
2

Installation: hammer drilled hole, Installation condition: Dry


Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement
Reinforcement to control splitting according to ETAG 001, Annex C, 5.2.2.6 present.

CBFEM
- The anchor calculation is based on a component-based Finite Element Method (CBFEM)

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

1
Hilti PROFIS Engineering 3.0.70

www.hilti.in
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Jul 7, 2021 Date: 07/07/2021
Fastening point:

1.1.1 Load combination


Case Description Forces [kN] / Moments [kNm] Seismic Fire Max. Util. Anchor [%]
1 Combination 1 N = 11.000; Vx = 2.000; Vy = 0.000; no no 18
Mx = 0.000; My = 0.000; Mz = 0.000;

1.2 Load case/Resulting anchor forces y

3 4
Anchor reactions [kN]
Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 4.477 0.507 0.506 0.018 Compression
2 4.510 0.494 0.494 0.013 x
3 4.481 0.507 0.506 -0.018
Tension
4 4.509 0.494 0.494 -0.013

resulting tension force in (x/y)=(0.3/0.0): 17.978 [kN] 1 2


resulting compression force in (x/y)=(0.7/0.1): 7.269 [kN]

Anchor forces are calculated based on a component-based Finite Element Method (CBFEM)

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

2
Hilti PROFIS Engineering 3.0.70

www.hilti.in
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Jul 7, 2021 Date: 07/07/2021
Fastening point:

1.3 Tension load (ETAG, Annex C, Section 5.2.2)

Load [kN] Capacity [kN] Utilization bN [%] Status


Steel Strength* 4.510 29.571 16 OK
Pullout Strength* 4.510 27.608 17 OK
Concrete Breakout Failure** 17.978 101.761 18 OK
Splitting failure** N/A N/A N/A N/A

* highest loaded anchor **anchor group (anchors in tension)

1.3.1 Steel Strength

N
NSd £ NRd,s = Rk,s ETAG 001 Annex C, Table 5.2.2.1
gM,s

NRk,s [kN] gM,s NRd,s [kN] NSd [kN]


41.400 1.400 29.571 4.510

1.3.2 Pullout Strength

y c · NRk,p
NSd £ NRd,p = ETAG 001 Annex C, Table 5.2.2.1
gM,p

NRk,p [kN] yc g M,p NRd,p [kN] NSd [kN]


35.000 1.183 1.500 27.608 4.510

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

3
Hilti PROFIS Engineering 3.0.70

www.hilti.in
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Jul 7, 2021 Date: 07/07/2021
Fastening point:

1.3.3 Concrete Breakout Failure

N
NSd £ NRd,c = Rk,c ETAG 001 Annex C, Table 5.2.2.1
gM,c
0 Ac,N
NRk,c = NRk,c · 0
· y s,N · y re,N · y ec1,N · y ec2,N ETAG 001 Annex C, Eq. (5.2)
Ac,N
0 1,5
NRk,c = k1 · √fck,cube · hef ETAG 001 Annex C, Eq. (5.2a)
0
Ac,N = scr,N · scr,N ETAG 001 Annex C, Eq. (5.2b)
c
y s,N = 0.7 + 0.3 · 1.00 ETAG 001 Annex C, Eq. (5.2c)
ccr,N £
hef
y re,N = 0.5 + 1.00 ETAG 001 Annex C, Eq. (5.2d)
200 £
1
y ec1,N = 1.00 ETAG 001 Annex C, Eq. (5.2e)
2 · ec1,N £
1+
scr,N
1
y ec2,N = 1.00 ETAG 001 Annex C, Eq. (5.2e)
2 · ec2,N £
1+
scr,N

2 0 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm]
230,400 90,000 150.0 300.0

ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N


0.3 0.998 0.0 1.000 1.000 1.000
0
k1 NRk,c [kN] gM,c NRd,c [kN] NSd [kN]
10.100 59.752 1.500 101.761 17.978

Group anchor ID
1-4

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

4
Hilti PROFIS Engineering 3.0.70

www.hilti.in
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Jul 7, 2021 Date: 07/07/2021
Fastening point:

1.4 Shear load (ETAG, Annex C, Section 5.2.3)

Load [kN] Capacity [kN] Utilization bV [%] Status


Steel Strength (without lever arm)* 0.507 23.600 3 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength** 2.000 203.955 1 OK
Concrete edge failure in direction x+** 2.000 50.128 4 OK

* highest loaded anchor **anchor group (relevant anchors)

1.4.1 Steel Strength (without lever arm)

V
VSd £ VRd,s = Rk,s ETAG 001 Annex C, Table 5.2.3.1
gM,s

VRk,s [kN] gM,s VRd,s [kN] VSd [kN]


29.500 1.250 23.600 0.507

1.4.2 Pryout Strength

V
VSd £ VRd,cp = Rk,cp ETAG 001 Annex C, Table 5.2.3.1
gM,c,p
VRk,cp = k · NRk,c ETAG 001 Annex C, Eq. (5.6)
0 A
NRk,c = NRk,c · 0c,N · y s,N · y re,N · y ec1,N · y ec2,N ETAG 001 Annex C, Eq. (5.2)
Ac,N
0 1,5
NRk,c = k1 · √fck,cube · hef ETAG 001 Annex C, Eq. (5.2a)
0
Ac,N = scr,N · scr,N ETAG 001 Annex C, Eq. (5.2b)
c
y s,N = 0.7 + 0.3 · 1.00 ETAG 001 Annex C, Eq. (5.2c)
ccr,N £
hef
y re,N = 0.5 + 1.00 ETAG 001 Annex C, Eq. (5.2d)
200 £
1
y ec1,N = 1.00 ETAG 001 Annex C, Eq. (5.2e)
2 · ec1,V £
1+
scr,N
1
y ec2,N = 1.00 ETAG 001 Annex C, Eq. (5.2e)
2 · ec2,V £
1+
scr,N

2 0 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] k-factor
230,400 90,000 150.0 300.0 2.000

ec1,V [mm] y ec1,N ec2,V [mm] y ec2,N y s,N y re,N


0.0 1.000 0.0 1.000 1.000 1.000
0
NRk,c [kN] gM,c,p VRd,cp [kN] VSd [kN]
59.752 1.500 203.955 2.000

Group anchor ID
1-4

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

5
Hilti PROFIS Engineering 3.0.70

www.hilti.in
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Jul 7, 2021 Date: 07/07/2021
Fastening point:

1.4.3 Concrete edge failure in direction x+

V
VSd £ VRd,c = Rk,c ETAG 001 Annex C, Table 5.2.3.1
gM,c
0 Ac,V
VRk,c = VRk,c · 0
· y s,V · y h,V · y a,V · y ec,V · y re,V ETAG 001 Annex C, Eq. (5.7)
Ac,V
0 a b 1,5
VRk,c = k1 · dnom · lf · √fck,cube · c1 ETAG 001 Annex C, Eq. (5.7a)
0,5
a = 0.1 · () lf
c1
ETAG 001 Annex C, Eq. (5.7b)
0,2

= 0.1 · (
c )
d nom
b ETAG 001 Annex C, Eq. (5.7c)
1
0 2
Ac,V = 4.5 · c1 ETAG 001 Annex C, Eq. (5.7d)
c2
y s,V = 0.7 + 0.3 · 1.00 ETAG 001 Annex C, Eq. (5.7e)
1.5 · c1 £
0,5
y h,V = (1.5h· c ) 1
³ 1.00 ETAG 001 Annex C, Eq. (5.7f)


1
2
y a,V =
(cos aV) +
2
(sin2.5a )
V ³ 1.00 ETAG 001 Annex C, Eq. (5.7g)

1
y ec,V = 1.00 ETAG 001 Annex C, Eq. (5.7h)
2 · ec,V £
1+
3 · c1

lf [mm] dnom [mm] k1 a b


100.0 12.00 2.400 0.058 0.053
2 0 2
c1 [mm] Ac,V [mm ] Ac,V [mm ]
300.0 232,500 405,000

y s,V y h,V y a,V ec,V [mm] y ec,V y re,V


0.900 1.342 1.000 0.0 1.000 1.000
0
VRk,c [kN] gM,c VRd,c [kN] VSd [kN]
108.466 1.500 50.128 2.000

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

6
Hilti PROFIS Engineering 3.0.70

www.hilti.in
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Jul 7, 2021 Date: 07/07/2021
Fastening point:

1.5 Combined tension and shear loads (ETAG, Annex C, Section 5.2.4)
Steel failure

bN bV a Utilization bN,V [%] Status


0.177 0.040 1.500 9 OK

a a
bN + bV £ 1.0

1.6 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates as per current regulations (ETAG 001/Annex C, EOTA
TR029, etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor
plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates
the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above.
The proof if the rigid base plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for
agreement with the existing conditions and for plausibility!
• Checking the transfer of loads into the base material is required in accordance with ETAG 001, Annex C(2010)Section 7! The software
considers that the grout is installed under the anchor plate without creating air voids and before application of the loads.
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of ETAG 001, Annex C! For larger
diameters of the clearance hole see Chapter 1.1. of ETAG 001, Annex C!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• The anchor design methods in PROFIS Engineering require rigid anchor plates, as per current regulations (AS 5216:2018, ETAG 001/Annex
C, EOTA TR029 etc.). This means that the anchor plate should be sufficiently rigid to prevent load re-distribution to the anchors due to
elastic/plastic displacements. The user accepts that the anchor plate is considered close to rigid by engineering judgment."
• The characteristic bond resistances depend on the return period (service life in years): 50

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

7
Hilti PROFIS Engineering 3.0.70

www.hilti.in
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Jul 7, 2021 Date: 07/07/2021
Fastening point:

1.7 Installation data


2
Anchor plate, steel: E 165 (Fe 290); E = 200,000.00 N/mm ; fyk = 165.00 Anchor type and diameter: HSA M12 hnom3
2
N/mm
Profile: Rectangular Hollow Sections India, 122x61x5.4; (L x W x T) = 122.0 Item number: 2004157 HSA M12x145 65/50/15
mm x 61.0 mm x 5.4 mm
Hole diameter in the fixture: df = 14.0 mm Maximum installation torque: 50 Nm
Plate thickness (input): 12.0 mm Hole diameter in the base material: 12.0 mm
Hole depth in the base material: 122.0 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 180.0 mm
Cleaning: Manual cleaning of the drilled hole according to instructions for use is
required.

Hilti HSA stud anchor with 114 mm embedment, M12 hnom3, Steel galvanized, installationwith torque control bar per ETA 11/0374

1.7.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Manual blow-out pump • Hilti SIW 6AT-A22 + SI AT-A22
• Properly sized drill bit • Hilti SFC 22-A drill driver
• Installation torque control bar with suitable
screw driver or torque wrench
• Hammer

y
125.0 125.0
35.0

3 4
125.0
180.0

x
125.0

1 2
35.0

35.0 180.0 35.0

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y
1 -90.0 -90.0 - 480.0 300.0 -
2 90.0 -90.0 - 300.0 300.0 -
3 -90.0 90.0 - 480.0 480.0 -
4 90.0 90.0 - 300.0 480.0 -

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

8
Hilti PROFIS Engineering 3.0.70

www.hilti.in
Company: Page: 9
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Jul 7, 2021 Date: 07/07/2021
Fastening point:

2 Anchor plate design

2.1 Input data


Anchor plate: Shape: Rectangular
lx x ly x t = 250.0 mm x 250.0 mm x 12.0 mm
Calculation: CBFEM
Material: E 165 (Fe 290); Fy = 165.00 N/mm²; εlim = 5.00%
Anchor type and size: HSA M12 hnom3, hef = 100.0 mm
Anchor stiffness: The anchor is modeled considering stiffness values determined from load displacement curves tested in an
independent laboratory. Please note that no simple replacement of the anchor is possible as the anchor
stiffness has a major impact on the load distribution results.
Design method: IS800-based design using component-based FEM
Stand-off installation: eb = 0.0 mm (No stand-off); t = 12.0 mm
Profile: 122x61x5.4; (L x W x T x FT) = 122.0 mm x 61.0 mm x 5.4 mm x -
Material: E 165 (Fe 290); Fy = 165.00 N/mm²; εlim = 5.00%
Eccentricity x: 0.0 mm
Eccentricity y: 0.0 mm
Base material: Uncracked concrete; M 35; fc,cube = 35.00 N/mm²; h = 250.0 mm; E = 32,500.00 N/mm²; G = 13,541.67
N/mm²; v = 0.20
Welds (profile to anchor plate): Type of redistribution: Plastic
Stiffeners: Geometry: Triangular; size = lx x ly x t = 120.0 mm x 50.0 mm x 4.0 mm
Material: E 165 (Fe 290); Fy = 165.00 N/mm²; εlim = 5.00%
Welds (stiffeners to profile/anchor Type of redistribution: Plastic
plate):
Mesh size: Number of elements on edge: 8
Min. size of element: 10.0 mm
Max. size of element: 50.0 mm

2.2 Summary
Description Profile Stiffeners Anchor plate Welds [%] Concrete
[%]
sEd [N/mm²] ePl [%] sEd [N/mm²] ePl [%] sEd [N/mm²] ePl [%] Hole bearing
[%]
1 Combination 17.64 0.00 40.39 0.00 28.86 0.00 1 24 441
1
2.3 Anchor plate classification
Results below are displayed for the decisive load combinations: Combination 1
Anchor tension forces Equivalent rigid anchor plate (CBFEM) Component-based Finite Element Method
(CBFEM) anchor plate design
Anchor 1 2.747 kN 4.477 kN
Anchor 2 2.753 kN 4.510 kN
Anchor 3 2.747 kN 4.481 kN
Anchor 4 2.753 kN 4.509 kN

User accepted to consider the selected anchor plate as rigid by his/her engineering judgement. This means the anchor design guidelines can
be applied.

2.4 Profile/Stiffeners/Plate
Profile and stiffeners are verified at the level of the steel to concrete connection. The connection design does not replace the steel design for
critical cross sections, which should be performed outside of PROFIS Engineering.

2.4.1 Equivalent stress and plastic strain

Limit state criteria as per IS 800, sEd <= fy, ePl <= elim.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

9
Hilti PROFIS Engineering 3.0.70

www.hilti.in
Company: Page: 10
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Jul 7, 2021 Date: 07/07/2021
Fastening point:

Results
Part Load Material sEd [N/mm²] ePl [%] fy [N/mm²] gM0 fy/gM0 elim [%] Status
combination [N/mm²]
Plate Combination E 165 (Fe 28.86 0.00 165.00 1.10 150.00 5.00 OK
1 290)
Profile Combination E 165 (Fe 7.47 0.00 165.00 1.10 150.00 5.00 OK
1 290)
Profile Combination E 165 (Fe 17.64 0.00 165.00 1.10 150.00 5.00 OK
1 290)
Profile Combination E 165 (Fe 16.55 0.00 165.00 1.10 150.00 5.00 OK
1 290)
Profile Combination E 165 (Fe 16.52 0.00 165.00 1.10 150.00 5.00 OK
1 290)
Stiffenera Combination E 165 (Fe 40.27 0.00 165.00 1.10 150.00 5.00 OK
1 290)
Stiffenerb Combination E 165 (Fe 40.32 0.00 165.00 1.10 150.00 5.00 OK
1 290)
Stiffenerc Combination E 165 (Fe 40.39 0.00 165.00 1.10 150.00 5.00 OK
1 290)
Stiffenerd Combination E 165 (Fe 40.34 0.00 165.00 1.10 150.00 5.00 OK
1 290)

2.4.1.1 Equivalent stress


Results below are displayed for the decisive load combination: 1 - Combination 1

150.00 N/mm²

0.00 N/mm²

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

10
Hilti PROFIS Engineering 3.0.70

www.hilti.in
Company: Page: 11
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Jul 7, 2021 Date: 07/07/2021
Fastening point:

2.4.1.2 Plastic strain


Results below are displayed for the decisive load combination: 1 - Combination 1

5.00%

0.00%
2.4.2 Hole bearing
Decisive load combination: 1 - Combination 1
Plate hole bearing resistance, IS 800 section 10.3.4:

Equations

Vndpb
Vdpb =
gmb
Vndpb = 2.5kbdtfu
Vsb
Utilization =
Vdpb

Variables
kb e [mm] p [mm] d0 [mm²] d [mm²] t [mm] fu [N/mm²] gmb
Anchor 1 0.83 35.0 ∞ 14.0 12.0 12.0 290.00 1.25
Anchor 2 1.00 215.1 180.0 14.0 12.0 12.0 290.00 1.25
Anchor 3 0.83 35.0 ∞ 14.0 12.0 12.0 290.00 1.25
Anchor 4 1.00 215.1 180.0 14.0 12.0 12.0 290.00 1.25

Results
Vndpb [kN] Vsb [kN] Vdpb [kN] Utilization [%] Status
Anchor 1 87.054 0.507 69.643 1 OK
Anchor 2 104.400 0.494 83.520 1 OK
Anchor 3 87.054 0.507 69.643 1 OK
Anchor 4 104.400 0.494 83.520 1 OK

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

11
Hilti PROFIS Engineering 3.0.70

www.hilti.in
Company: Page: 12
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Jul 7, 2021 Date: 07/07/2021
Fastening point:

2.5 Welds
Profiles are modeled without taking the corner radius into account. Special rules for welding (e.g. for cold-formed profiles ...) are not taken into
account by the software.
The ultimate stress of the welding electrodes selected should be verified.
The verification of full penetration butt welds is not carried out, as it is assumed that the weld material has the same, or larger resistance than
both parent materials (welds, plate or profile), as per IS 800, section 10.5.7.1.2.

2.5.1 Anchor plate to profile


Decisive load combination: 1 - Combination 1
Weld design IS 800, 10.5.10.1.1
Minimum anchor plate to profile flange: Leg thickness = 5.0 mm, Throat thickness = 3.5 mm
The thicker element should be adequately preheated to prevent cracking of the weld.

Equations

fu
fe = √(fa2 + 3q2) ≤ fwd =
√3gmw
fe
Utilization =
fwd

Variables
Edge l [mm] tt [mm] tl [mm] fa [N/mm²] q [N/mm²] fu [N/mm²] gmw
Member 1-tfl 1 60.8 6.0 8.5 4.47 0.86 290.00 1.25
Member 1-bfl 1 60.8 6.0 8.5 4.41 1.25 290.00 1.25

Results
Edge fe [N/mm²] fwd [N/mm²] Utilization [%] Status
Member 1-tfl 1 4.71 133.95 4 OK
Member 1-bfl 1 4.91 133.95 4 OK

2.5.2 Stiffeners to profile/anchor plate


Decisive load combination: 1 - Combination 1
Weld design IS 800, 10.5.10.1.1
Minimum stiffener to plate weld: Leg thickness = 4.0 mm, Throat thickness = 2.8 mm
The thicker element should be adequately preheated to prevent cracking of the weld.

Equations

fu
fe = √(fa2 + 3q2) ≤ fwd =
√3gmw
fe
Utilization =
fwd

Variables
Edge l [mm] tt [mm] tl [mm] fa [N/mm²] q [N/mm²] fu [N/mm²] gmw
Stiffenera 49.9 4.0 5.7 16.77 15.02 290.00 1.25
Stiffenera 1 49.9 4.0 5.7 16.76 10.04 290.00 1.25
Stiffenerb 49.9 4.0 5.7 16.74 10.12 290.00 1.25
Stiffenerb 1 49.9 4.0 5.7 16.75 15.10 290.00 1.25
Stiffenerc 49.9 4.0 5.7 17.54 10.44 290.00 1.25
Stiffenerc 1 49.9 4.0 5.7 17.36 15.32 290.00 1.25

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

12
Hilti PROFIS Engineering 3.0.70

www.hilti.in
Company: Page: 13
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Jul 7, 2021 Date: 07/07/2021
Fastening point:

Edge l [mm] tt [mm] tl [mm] fa [N/mm²] q [N/mm²] fu [N/mm²] gmw


Stiffenerd 49.9 4.0 5.7 17.19 15.29 290.00 1.25
Stiffenerd 1 49.9 4.0 5.7 17.37 10.40 290.00 1.25

Results
Edge fe [N/mm²] fwd [N/mm²] Utilization [%] Status
Stiffenera 30.96 133.95 23 OK
Stiffenera 1 24.14 133.95 18 OK
Stiffenerb 24.23 133.95 18 OK
Stiffenerb 1 31.06 133.95 23 OK
Stiffenerc 25.20 133.95 19 OK
Stiffenerc 1 31.71 133.95 24 OK
Stiffenerd 31.57 133.95 24 OK
Stiffenerd 1 25.03 133.95 19 OK

2.6 Concrete
Decisive load combination: 1 - Combination 1
The concrete should have sufficient reinforcement to take into account the tensile forces that develop due to the fixture attachment. The
definition of the reinforcement in the concrete is out of scope of PROFIS Engineering.

2.6.1 Compression in concrete under the anchor plate, IS800, section 7.4
1.79 N/mm²

0.00 N/mm²

Equations

N
s = A
1

s ≤ 0.6fck

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

13
Hilti PROFIS Engineering 3.0.70

www.hilti.in
Company: Page: 14
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Jul 7, 2021 Date: 07/07/2021
Fastening point:

Variables
fck [N/mm²] A1 [mm²] N [kN]
35.00 79 7.269

Results
s [N/mm²] 0.6fck [N/mm²] Utilization [%] Status
92.50 21.00 441 NOT OK

2.7 Symbol explanation


A1 Loaded area of concrete
A2 Supporting area
d Nominal diameter of the bolt
d0 Hole diameter in the steel fixture
e End distance of the fastener along bearing direction
elim Limit plastic strain
ePl Plastic strain from CBFEM results
fa Weld normal stress (compression or tension) due to axial force or bending moment.
fck Characteristic compressive concrete strength
fe Equivalent stress in weld.
fu Ultimate strength
fwd Design strength of a fillet weld.
fy Yield strength
gM0 Steel safety factor gamma M0
gmb Plate hole bearing safety factor
gmw Welds safety factor
kb Factor for joint geometry and material strength
l Length of weld
N Resulting compression force
s Average stress in concrete
sEd Equivalent stress
p Pitch distance of the fastener along bearing direction
t Thickness of the anchor plate
q Weld shear stress due to shear force or tension.
tl Leg length of the weld
tt Throat thickness of the weld
Vdpb Plate hole bearing design strength
Vndpb Plate hole bearing nominal strength
Vsb Plate hole bearing load

2.8 Warnings
● By using the CBFEM calculation functionality of PROFIS Engineering you may act outside the applicable design codes and your specified
anchor plate may not behave rigid. Please, validate the results with a professional designer and/or structural engineer to ensure suitability
and adequacy for your specific jurisdiction and project requirements.
● The anchor is modeled considering stiffness values determined from load displacement curves tested in an independent laboratory.
Please note that no simple replacement of the anchor is possible as the anchor stiffness has a major impact on the load distribution
results.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

14
Hilti PROFIS Engineering 3.0.70

www.hilti.in
Company: Page: 15
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Jul 7, 2021 Date: 07/07/2021
Fastening point:

3 Summary of results
Design of the anchor plate, anchor, welds and other elements are based on CBFEM (component based finite element method) and Eurocode
regulations.
Load combination Max. utilization Status
Anchors Combination 1 18% OK
Anchor plate Combination 1 18% OK
Welds Combination 1 24% OK
Stiffeners Combination 1 25% OK
Concrete Combination 1 441% NOT OK
Profile Combination 1 11% OK

Fastening does not meet the design criteria!

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

15
Hilti PROFIS Engineering 3.0.70

www.hilti.in
Company: Page: 16
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Jul 7, 2021 Date: 07/07/2021
Fastening point:

4 Remarks; Your Cooperation Duties


● Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles,
formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc.,
that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be
conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based
essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the
relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and
cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility.
The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and
the relevance of the results or suitability for a specific application.
● You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you
do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the
Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery
of lost or damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

16

You might also like