General
2. Which ratio grid requires the highest milliamperes (mAs) to obtain the desired
density on a finished radiographic film?
a. 8:1
b. 12:1
c. 10:1
d. 5:1
5. Which type of x-ray machine allows for faster time and more output?
a. Half-wave rectified, single phase
b. Full-wave rectified, single phase
c. Full-wave rectified, three phase
d. Self-rectified
6. Which of the following controls radiographic contrast?
a. kVp
b. mAs
c. Focal film distance
d. Object film distance
11. When a spin top test is performed on a full-wave rectified machine, how many dots
should you see in 1/60 second?
a. 6
b. 2
c. 1
d. 12
12. If you suspect that your machine is not producing x-radiation, what test can you
perform?
a. Spin top
b. Film/screen contact
c. Step wedge
d. Screen fluorescence
15. Which direction should a grid move in relation to the grid lines in order to blur
lines?
a. Same direction as the grid lines
b. Perpendicular to the grid lines
c. Always stationary
d. Moves in both directions
16. If the focal-film distance is increased by a factor of 2, how must the milliamps be
adjusted to maintain density?
a. Increased by a factor or 4
b. Increased by a factor of 2
c. Decreased by a factor of 4
d. Decreased by a factor of 2
17. If a radiographic film appears overexposed, is it too light or too dark? Would you
increase or decrease the exposure to improve the quality?
a. Too dark; exposure should be increased
b. Too light; exposure should be increased
c. Too dark; exposure should be decreased
d. Too light; exposure should be decreased
18. How does kVp affect the electrons and the x-ray beam?
a. Increasing it increases the number of electrons produced and also increases the
penetrating power of the x-ray beam
b. Decreasing it decreases the number of electrons produced and also decreases the
number of x-rays produced
c. Increasing it increases the speed at which electrons are pulled across to the anode
and also increases the penetrating power of the x-ray beam
d. Increasing it increases the speed at which electrons are pulled across to the anode
and lengthens the wavelength of the x-rays produced, making them more
penetrating
22. What effect does doubling the mAs have on radiographic density?
a. Doubles it
b. Halves it
c. Density is the same
d. Radiographic film is blackened
23. The electron cloud is generated at the
a. Anode
b. Cathode
c. Focal spot
d. Effective focal spot
24. Which technique produces the image with the most radiographic density?
a. 1 00 mA, l/10 sec
b. 1 50 mA, 1/30 sec
c. 200 mA, 1/20 sec
d. 200 mA, 1/10 sec
29. Which contrast study requires the patient's head to be elevated after injection of
contrast medium?
a. Arthrography
b. Fistulography
c. Myelography
d. Pneumoperitonography
30. Which contrast medium is be considered positive contrast?
a. Nitrous oxide
b. Air
c. Barium sulfate
d. Oxygen
31. Which contrast study is used to evaluate the kidneys, ureters, and urinary
bladder?
a. Urethrography
b. Positive-contrast cystography
c. Double-contrast cystography
d. Excretory urography
32. Which contrast medium appears radiolucent on the finished radiographic film?
a. Barium sulfate
b. Metrizamide
c. Air
d. Water-soluble organic iodide
33. Which contrast study of the gastrointestinal tract is monitored until contrast
medium reaches the colon?
a. Gastrography
b. Upper gastrointestinal series
c. Barium enema
d. Esophagography
34. Which of the following is not a reason why survey radiographic films should always
be made before administering contrast medium?
a. To establish proper exposure technique
b. To establish proper patient preparation
c. To make a diagnosis
d. To help determine the dosage of contrast medium
38. With the heel effect, the x-ray beam intensity is greater toward the
a. Anode
b. Collimator
c. Cathode
d. Tube window
39. Which factor does not affect the amount of penumbra on a radiographic film and
does not contribute to the penumbra?
a. Object-film distance
b. kVp
c. Focal-film distance
d. Focal spot size
40. The spin top test is performed when you suspect a problem with the
a. mA stations
b. X-ray tube
c. Timer
d. kVp
Darkroom
A good layout of a darkroom should include dry bench and wet bench areas, separate
from one another. For Questions 41 through 44, select the area where each task should
be performed from the two choices below.
a. Wet bench
b. Dry bench
45. How do low-grade light leaks in the darkroom affect film quality?
a. They have no effect on the film quality
b. They increase film quality by decreasing scatter radiation
c. They decrease film quality by increasing overall fog of the film
d. They decrease film quality by decreasing radiographic density
46. When must radiographs be labeled for certification organizations and for legal
purposes?
a. Before exposure and after processing
b. During or after exposure but before processing
c. After exposure and after processing
d. Before filing or mailing
47. What is the total time the film should be placed in the fixer?
a. Two times the developing time
b. Three times the developing time
c. The same as the developing time
d. 30 seconds
48. A radiographic film of a dog's thorax is made. What occurs when the film is placed
in the developer?
a. The sensitized silver halide crystals are changed into black metallic silver
b. The potassium bromide crystals are changed into black metallic silver
c. The silver halide crystals are cleared from the film
d. All the silver halide crystals are changed into black metallic silver
When manually processing films, there are two methods for maintaining the tanks: the
exhausted method and the replenishing method. Answer Questions 49 through 51 by
matching the two methods with the statements.
a. Exhausted method
b. Replenishing method
49. Allows chemicals to drain from the film back into their respective tanks.
51. Periodically, chemicals are added to bring chemical levels back up to the top of
the tanks.
52. How often should the manual processing tanks be drained and cleaned and old
chemicals replaced with fresh chemicals?
a. Once a day
b. Once a week
c. At least every 3 months
d. Once a year
53. What would happen if exposed film were accidentally placed in the fixer before
being placed in the developer?
a. The radiographic film turns black
b. The radiographic film becomes clear
c. If the mistake is detected soon enough, the image can be spared
d. The radiographic film appears underexposed
55. When reconstituting the powder form of processing chemicals, what is one
important factor to remember?
a. Always reconstitute the chemicals in the darkroom
b. Always reconstitute the chemicals under bright lights
c. Always use sterile saline to reconstitute the chemicals
d. Never reconstitute the chemicals in the darkroom
56. A radiographic film of a cat's thorax is made. When viewing the film, you note a
decrease in radiographic density and a gray swirly appearance of the background.
What caused this problem?
a. Processing chemicals were too hot
b. Film was not left in the fixer long enough
c. Processing chemicals were too cold
d. Film was not washed for 30 minutes after processing
57. Radiographic films made 5 years earlier have turned brown. What was the cause?
a. Too long in the developer
b. Too long in the fixer
c. Incomplete development
d. Incomplete final wash
58. When using a direct safelight system, the distance from the workbench should be
at least
a. 20 inches
b. 30 inches
c. 48 inches
d. 72 inches
59. Lateral and ventrodorsal projections of a dog's abdomen are made and manually
processed at the same time. However, both radiographic films have identical areas
of decreased radiographic density. What could have caused this artifact on both
films?
a. They stuck together in the fixer
b. They stuck together in the developer
c. They stuck together in the wash tank
d. They were overexposed
Film
Animal positioning
75. When radiographing a joint, why is it important to center the primary beam
on the joint?
a. To decrease scatter radiation
b. To decrease exposure
e. To maximize joint space and minimize false narrowing
d. To minimize the joint space and maximize false narrowing
Image production
86. What procedure must be followed to take advantage of the heel effect when
obtaining a radiographic film?
a. Place the distal part of the patient toward the anode
b. Place the thick or dense part of the patient toward the cathode
c. Place the thick or dense part of the patient toward the anode
d. Place the heavy or dense part of the patient in the middle of the beam
88. Where should the primary beam be centered when radiographing the canine
lumbar spine in a ventrodorsal projection?
a. L2
b. L3
c. L4
d. LS
89. Where should the primary beam be centered for a lateral view of the canine
thoracic spine?
a. 13
b. TS
c. T7
d. T9
90. What is the purpose of the collimator on an x-ray machine?
a. Reduce the exposure time
b. Increase the detail of the x-ray film
c. Compensate for movement
d. Limit the primary beam size
91. If rnA = 100 and s = 1/10, what is the mAs of the x-ray exposure technique?
a. 1
b. 10
c. 100
d. 1,000
92. What x-ray intensifying screen provides the least detail on the developed film?
a. Low speed
b. Par speed
. c. High speed
d. Rare earth
93. Which setting on the x-ray machine adjusts the penetrating ability of the x-ray
beam?
a. mA
b. kVp
c. Time
d. Collimation
GENERAL
1. a The rnA selector controls the number of electrons produced at the filament.
2. b With a 12:1 ratio grid, more x-rays are absorbed, requiring more x-rays
to be produced or a higher mAs.
3. d A 12:1 ratio grid with 113 lines per inch absorbs more scatter, producing
an image with better contrast and less fogging on the finished radiographic film.
4. a
5. c A full-wave rectified, three phase allows for more positive potential across the
terminals of the tube, producing a higher energy of electrons and a more constant
energy x-ray beam.
8. a The focusing cup focuses the beam of electrons on the focai spot of the
anode.
10. d
11. b Two dots are seen when a spin top test is performed on a full-wave
rectified machine in 1/60 second. The spin top is the number of dots =
pulsation frequency x exposure time.
12. d A screen can be placed open under the x-ray beam and a low exposure
made. If x-radiation is being produced, the screen will fluoresce.
13. c Tube saturation occurs when there is not enough positive potential (voltage)
between the cathode and anode to pull all the electrons across the tube. The extra
electrons accumulate on the glass envelope and can crack the tube.
14. c Metal has the highest x-ray absorption because it is the most dense.
15. b A grid moves in the opposite direction from the grid lines. This erases the lines so
they are not visible on the radiographic film.
16. a The Inverse Square Law states that the intensity of the x-ray beam is inversely
proportional to the square of the distance from the source of the x¬rays. The same
number of x-rays must diverge, covering an area that is four times as large.
17. c
18. c
19. b Increasing the kVp 20% doubles the radiographic density and increases the
penetration.
20. c Because mAs controls the number of x-rays produced, reducing the mAs reduces
radiographic density.
21. a When kVp and mAs are too high for the machine, too much heat is created,
causing the anode to crack.
22. a mAs controls the number of x-rays produced. If the mAs is doubled, this doubles
the density on the radiographic film.
23. b The cathode holds the filament. When current is applied to the filament,
electrons boil off, producing an electron cloud.
24. d 200 rnA, 1/10 second = 20 mAs. This is the highest mAs, which produces more x-
rays.
25. d Celiography is useful when studying the abdominal cavity and the integrity of the
diaphragm.
27. a A barium enema generally uses both positive- and negative-contrast media to
evaluate the colon.
29. c The head is elevated after injection for a myelogram to decrease the chance of
seizure.
30. c Barium sulfate has a high atomic number and appears white on a radiographic
film.
31. d Excretory urography provides information relative to renal function and the
structure of the kidneys, ureters, and bladder.
33. b This contrast study is used to evaluate the stomach and small intestines. The
contrast medium is administered orally, and films are made during transit of the
contrast medium through the stomach and small bowel into the colon.
34. d The dose of contrast medium is calculated using the weight of the animal.
36. c Fistulography is a contrast study that delineates the extent and possibly the origin
of fistulous tracts.
37. a An excretory urogram identifies the size, shape, location, and margination of the
kidneys and ureters.
38. c The cathode has the higher x-ray beam intensity because x-rays are absorbed by
the target and anode.
39. b kVp controls the penetration power and scale of contrast on the film; it has no
effect on penumbra. Penumbra causes a loss of detail. There are three main factors
in the amount of penumbra on a radiographic film; these are focal-film distance,
object¬film distance, and focal-spot size.
40. c The spin top is number of dots = pulsation frequency x exposure time. If the
number of dots is incorrect, there is a problem with the timer.
DARKROOM
41. b
42. a
43. b
44. a
45. c When film is exposed to low-grade light leaks, a base fog decreases the overall
quality of the finished radiographic film, decreasing contrast and detail.
46. b For radiographic films to be legal in court and for the certification organizations
to accept them, they must be permanently identified. This can be done during the
exposure with lead letters or radiopaque tape or after the exposure, but the film
should be identified before the film is processed with manual or photo labelers.
47. a The total time the film must be in the fixer is double the time it was in the
developer. The film can be viewed on a view box after the film has been in the fixer
for only 30 seconds; however, it must be placed back into the fixer for the
remaining time to complete the process.
48. a
49. a
50. b
51. b
52. c The fluids in manual processing tanks should be changed at least every 3 months.
In busy practices the frequency may need to be increased to maintain the quality of
the radiographic film.
53. b The radiographic film is clear because the fixer removes all the silver halide
crystals that remain after being in the developer. If the film has not been placed in
the developer, the sensitized silver halide crystals have not yet been changed into
black metallic silver. The fixer then removes all the silver halide crystals, clearing
the film of any image.
54. c Developer chemicals are kept at an alkaline pH, usually 9.8 to 11.4. Developer
chemicals cannot function in a neutral or acid solution.
55. d The chemicals should be mixed in a bucket outside the darkroom to prevent the
chemical dust from contaminating unprotected films, thus causing artifacts.
56. c Most manufacturers recommend the processing chemicals be at least 68° F for
the chemicals to be efficient.
57. d If the films were not completely washed, the fixer that remained in the emulsion
would oxidize, turning them a brownish color.
58. c A direct system shines the safelight directly toward the workbench. To prevent
possible fogging of the film, the safelight should be placed at least 48 inches from
the workbench.
59. Because both had identical areas of decreased density, this means the films were
stuck together in the developer. The density is decreased because the developer
was not able to change the sensitized silver halide crystals into black metallic silver;
consequently, the fixer clears the remaining silver halide crystals. This leaves an
area of decreased density.
FILM
60. c A latent image is the silver halide crystals in the film's emulsion that have been
exposed to radiant energy, causing them to become susceptible to chemical
change.
61. a Screen-type film is more sensitive to the light from intensifying screens than
it is to direct x-ray exposure.
62. b The emulsion is too thick for some types of direct -exposure film to be
automatically processed. The processing chemicals cannot reach all of the silver halide
crystals in the time it takes to automatically process.
63. b Direct-exposure film requires that more x-rays be generated to expose it,
as it does not use the intensifying effect of the screens.
64. c Film is most sensitive after it has been exposed, but before it is processed. Care
l)1ust be taken when handling the film after it has been exposed.
65. b The crystal size in high-speed film is larger, allowing a decrease in mAs; however,
the detail is decreased as compared with that of slow-speed film.
67. d Film should be stored away from strong chemical fumes to prevent a
base fog on the film.
68. d When identifying films, the label should include the clinic's name; the
date; the owner's and patient's names; and the species, sex, and age of the patient.
ANIMAL POSITIONING
71. c To include the entire abdomen on a radiographic film, the cranial landmark is
three rib spaces cranial to the xiphoid and the caudal landmark is the greater
trochanter.
72. b
73. c The endotracheal tube is removed to prevent superimposition over the main
bony structures.
74. a Foreshortening occurs when the long bone is not parallel to the cassette, causing
the bone to appear shorter than it actually is.
75. c Centering the beam on the joint maximizes the size of the joint space and
minimize the amount of false narrowing that can occur as the center of the primary
beam is moved away from the joint.
76. b Extending the head caudodorsally moves the trachea off the shoulder joint;
extending the contralateral limb farther caudally moves the manubrium away from
the shoulder joint.
77 a
78. b
79. b
80. a
81. c
82. a
84. b
85. b With a left 20-degree ventralfright dorsal oblique projection of the skull, the right
tympanic bulla is delineated from the left.
IMAGE PRODUCTION
86. b Placing the thick part of the patient toward the cathode of the x-ray tube
produces a more uniform density on the radiographic film.
87. a Radiographic films are legal medical records and must contain all the information
found in answer a.
88. c L4 is midway between the pubis and the xyphoid cartilage in a dog lying in the
ventrodorsal position.
90. d To reduce the divergent x-ray energy beam, a restriction device can focus the
column of energy on the cassette.
92. c The larger the crystal size, the more light is produced. High-speed screens have
larger crystals, even bigger than the rare-earth crystals.
93. b Change in kVp changes the energy level of the x-ray beam.
94. a The distance between the source of an x-ray (focal spot) and the image
receptor (x-ray film) is called the focal-film distance.
95. b If the object being x-rayed is farther from the receptor, the image formed
on the film is magnified because the x-ray beam strikes the object farther
from the projected shadow.
96. b A less penetrating x-ray beam produces less scatter. A focused beam
also produces less scatter, and a grid reduces the scatter. All three of these
features increase detail by reducing the effect of scatter radiation.
97. c X-rays are more visibly converted to light by rare-earth phosphorus than
by calcium tungstate, a major factor in reducing exposure time. All the
other items have no effect on exposure time reduction.
98. a
99. d The area of contrast is dependent upon the density and mass of the
tissue or subject.
100. c Scatter radiation originates from the patient as the primary beam strikes
the first solid object and produces secondary radiation.