PC123/PC123F: European Safety Standard Approved Type Long Creepage Distance Photocoupler
PC123/PC123F: European Safety Standard Approved Type Long Creepage Distance Photocoupler
4.58 ± 0.3
2.54± 0.25
Approved by VDE ( DIN-VDE83601 ) PC123
Approved by BSI
1.0 ± 0.1
1.2 ± 0.3
2 3
6.5 ± 0.3
( BS415 No. 7087, BS7002 No. 7409 )
4.58 ± 0.3
Approved by SEMCO ( No. 9216212 ) 7.62 ± 0.3
3.5 ± 0.5
Approved by DEMCO ( No. 108954 )
Approved by NEMKO ( No. 199438181 )
3.05 ± 0.5
± 0.5
Epoxy resin
Approved by EI ( No. 155030 )
3.4
Recognized by CSA (No. CA95323) 0.26 ± 0.1 0.5 ± 0.1
2. OA equipment
PC123
1.0 ± 0.1
1.2 ± 0.3
2 6.5 ± 0.3 3
■ Absolute Maximum Ratings ( Ta = 25˚C )
4.58 ± 0.3
Parameter Symbol Ratings Unit 7.62 ± 0.3
3.5 ± 0.5
Forward current IF 50 mA
*1
Peak forward current I FM 1 A
2.7MIN.
“ In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device. ”
PC123/PC123F
50 100
( mA )
40 80
F
Forward current I
70
30 60
20 40
25
10 20
0 0
- 30 0 25 50 75 100 125 - 30 0 50 100
250
100 150
100
50
50
0
0
- 30 0 25 50 75 100 125 - 30 0 25 50 75 100 125
Ambient temperature T a ( ˚C ) Ambient temperature T a ( ˚C )
Fig. 5 Peak Forward Current vs. Duty Ratio Fig. 6 Forward Current vs.
Forward Voltage
10000 1000
Pulse width <=100µs
5000 T a = 25˚C 500
+ 25˚C
( mA )
2000
( mA )
200
1000 T a = 75˚C - 25˚C
FM
100
F
Peak forward current I
Forward current I
500 50
50˚C 0˚C
200
20
100
10
50
5
20
10 2
5 1
5 10 - 3 2 5 10 -2 2 5 10 -1 2 5 1 0 0.5 1.0 1.5 2.0 2.5 3.0
Duty ratio Forward voltage V F ( V )
Fig. 7 Current Transfer Ratio vs. Fig. 8 Collector Current vs. Collector-emitter
Forward Current Voltage
300
V CE = 5V T a = 25˚C
60
T a = 25˚C
Current transfer ratio CTR ( % )
250 54
( mA )
P C ( MAX. )
48
200
C
42
Collector current I
36
150
30 mA
30
24 = mA
100 I F 20
=
18 IF
I F = 10mA
50 12
6 I F = 5mA
0 0
0.1 1 10 100 0 1 2 3 4 5 6 7 8 9 10
Forward current I F ( mA ) Collector-emitter voltage V CE ( V )
PC123/PC123F
Fig. 9 Relative Current Transfer Ratio vs. Fig.10 Collector-emitter Saturation Voltage vs.
Ambient Temperature Ambient temperature
150 0.16
I F = 20mA
0.12
100
0.10
0.08
0.06
50
0.04
0.02
0
0.00
- 30 0 25 50 75 100 - 30 0 20 40 60 80 100
Ambient temperature T a ( ˚C ) Ambient temperature T a ( ˚C )
10 -6
5 T a = 25˚C
CEO
100
Response time ( µ s )
10 -7
Collector dark current I
5 tr
-8 tf
10 10
5
td
10 -9
5 ts
1
10 - 10
5
10 - 11 0.1
- 30 0 20 40 60 80 100 0.01 0.1 1 10 100
Ambient temperature T a ( ˚C ) Load resistance ( k Ω )
V CE = 5V T a = 25˚C
I C = 2mA 5.0 I C = 0.5mA
CE(sat)
4.0 5mA
Voltage gain Av ( dB )
7mA
3.5
-5
3.0
2.5
- 10
2.0
www.datasheetcatalog.com