Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

28 July 2021

Extend by
Extend by 60mm
40mm
Project: 2 Pioneer Sector 1
Calculation For: Stress Check due to ECC
Column/Pile Group Type C-L16c1 C-L16c2 36P_400SQ Zone 2 Column Load Pile Capacity
Load Combination Type Combi 1 (5) Comb1 71300 Combi 1 3100
Column Loads,N 71300 kN; 𝑁 1980.6 kN Comb 2 57000 Combi 2 1900
No of Piles,n 36 𝑛
(0,0) (6) (7) Load per pile Pile Capacity Remarks
Coordinates (1) (2) (1)*(1) (2)*(2) (1)*(3) (2)*(4) (5)+(6)+(7)
Pile No. ECC (x) ECC (y) X Y xn yn Xn,bar Yn,bar Iyy Ixx
1 -4 12 450 450 446.00 462.00 2985 2973 8.908733 8.840 -26.1 -21 1933.6 < 3100 ok
2 -106 -67 1650 450 1544.00 383.00 1887 3052 3.559826 9.316 -16.5 -21 1942.6 < 3100 ok
3 -76 -58 2850 450 2774.00 392.00 657 3043 0.431321 9.261 -5.7 -21 1953.4 < 3100 ok
4 -111 -3 4050 450 3939.00 447.00 -508 2988 0.258318 8.929 4.4 -21 1964.0 < 3100 ok
5 58 -69 5250 450 5308.00 381.00 -1877 3054 3.524068 9.328 16.4 -21 1975.4 < 3100 ok
6 43 29 6450 450 6493.00 479.00 -3062 2956 9.377375 8.739 26.7 -21 1986.5 < 3100 ok
7 -8 9 450 1650 442.00 1659.00 2989 1776 8.932627 3.155 -26.1 -12 1942.0 < 3100 ok
8 -81 22 1650 1650 1569.00 1672.00 1862 1763 3.466113 3.109 -16.3 -12 1951.9 < 3100 ok
9 -165 -28 2850 1650 2685.00 1622.00 746 1813 0.556143 3.287 -6.5 -13 1961.3 < 3100 ok
10 30 29 4050 1650 4080.00 1679.00 -649 1756 0.421526 3.084 5.7 -12 1973.9 < 3100 ok
11 113 77 5250 1650 5363.00 1727.00 -1932 1708 3.73359 2.918 16.9 -12 1985.4 < 3100 ok
12 -2 -71 6450 1650 6448.00 1579.00 -3017 1856 9.103798 3.445 26.3 -13 1993.8 < 3100 ok
13 -115 -30 450 2850 335.00 2820.00 3096 615 9.583668 0.378 -27.0 -4 1949.2 < 3100 ok
14 -80 8 1650 2850 1570.00 2858.00 1861 577 3.462391 0.333 -16.2 -4 1960.3 < 3100 ok
15 15 -82 2850 2850 2865.00 2768.00 566 667 0.320073 0.445 -4.9 -5 1970.9 < 3100 ok
16 102 53 4050 2850 4152.00 2903.00 -721 532 0.520202 0.283 6.3 -4 1983.1 < 3100 ok
17 138 5 5250 2850 5388.00 2855.00 -1957 580 3.830828 0.337 17.1 -4 1993.6 < 3100 ok
18 134 30 6450 2850 6584.00 2880.00 -3153 555 9.942986 0.308 27.5 -4 2004.2 < 3100 ok
19 -34 -49 450 4050 416.00 4001.00 3015 -566 9.088718 0.320 -26.3 4 1958.2 < 3100 ok
20 30 20 1650 4050 1680.00 4070.00 1751 -635 3.065126 0.403 -15.3 4 1969.7 < 3100 ok
21 39 27 2850 4050 2889.00 4077.00 542 -642 0.293493 0.412 -4.7 5 1980.3 < 3100 ok
22 -112 -113 4050 4050 3938.00 3937.00 -507 -502 0.257303 0.252 4.4 4 1988.5 < 3100 ok
23 -334 24 5250 4050 4916.00 4074.00 -1485 -639 2.205968 0.408 13.0 4 1998.0 < 3100 ok
24 125 18 6450 4050 6575.00 4068.00 -3144 -633 9.886308 0.401 27.4 4 2012.5 < 3100 ok
25 -55 -72 450 5250 395.00 5178.00 3036 -1743 9.215778 3.038 -26.5 12 1966.3 < 3100 ok
26 -106 -9 1650 5250 1544.00 5241.00 1887 -1806 3.559826 3.261 -16.5 13 1976.8 < 3100 ok
27 19 -60 2850 5250 2869.00 5190.00 562 -1755 0.315563 3.080 -4.9 12 1988.0 < 3100 ok
28 -33 -34 4050 5250 4017.00 5216.00 -586 -1781 0.343689 3.171 5.1 13 1998.2 < 3100 ok
29 41 17 5250 5250 5291.00 5267.00 -1860 -1832 3.46053 3.356 16.2 13 2009.7 < 3100 ok
30 5 -65 6450 5250 6455.00 5185.00 -3024 -1750 9.146088 3.062 26.4 12 2019.3 < 3100 ok
31 -19 8 450 6450 431.00 6458.00 3000 -3023 8.9985 9.138 -26.2 21 1975.6 < 3100 ok
32 -97 -25 1650 6450 1553.00 6425.00 1878 -2990 3.525945 8.939 -16.4 21 1985.2 < 3100 ok
33 -79 -54 2850 6450 2771.00 6396.00 660 -2961 0.43527 8.767 -5.8 21 1995.6 < 3100 ok
34 -121 -19 4050 6450 3929.00 6431.00 -498 -2996 0.248253 8.975 4.3 21 2006.0 < 3100 ok
35 46 5 5250 6450 5296.00 6455.00 -1865 -3020 3.479158 9.120 16.3 21 2018.1 < 3100 ok
36 107 -20 6450 6450 6557.00 6430.00 -3126 -2995 9.773439 8.969 27.3 21 2028.9 < 3100 ok

Sum -693 -535 124200 124200 123507.00 123665.00 157.2325 150.564


Effective CG of Group -19.3 -14.9 3450.0 3450.0 3430.8 3435.1 (3) (4)
-19.3 -14.9 -8.729268 -7.03750338
eyy exx 𝑁. 𝑒𝑦𝑦 𝑁. 𝑒𝑥𝑥
𝐼𝑦𝑦 𝐼𝑥𝑥
Outcome: Pile group ecc is within tolerance of 75mm in both x and y directions. 28 Jul 2021
Project: 2 Pioneer Sector 1
Calculation For: Stress Check due to ECC
Column/Pile Group Type C-L16c1 C-L16c2 36P_400SQ Zone 2 Column Load Pile Capacity
Load Combination Type Combi 2 (5) Comb1 71300 Combi 1 3100
Column Loads,N 57000 kN; 𝑁 1583.3 kN Comb 2 57000 Combi 2 1900
No of Piles,n 36 𝑛
(0,0) (6) (7) Load per pile Pile Capacity Remarks
Coordinates (1) (2) (1)*(1) (2)*(2) (1)*(3) (2)*(4) (5)+(6)+(7)
Pile No. ECC (x) ECC (y) X Y xn yn Xn,bar Yn,bar Iyy Ixx
1 -4 12 450 450 446.00 462.00 2985 2973 8.908733 8.840 -20.8 -17 1545.8 < 1900 ok
2 -106 -67 1650 450 1544.00 383.00 1887 3052 3.559826 9.316 -13.2 -17 1553.0 < 1900 ok
3 -76 -58 2850 450 2774.00 392.00 657 3043 0.431321 9.261 -4.6 -17 1561.6 < 1900 ok
4 -111 -3 4050 450 3939.00 447.00 -508 2988 0.258318 8.929 3.5 -17 1570.1 < 1900 ok
5 58 -69 5250 450 5308.00 381.00 -1877 3054 3.524068 9.328 13.1 -17 1579.3 < 1900 ok
6 43 29 6450 450 6493.00 479.00 -3062 2956 9.377375 8.739 21.4 -17 1588.1 < 1900 ok
7 -8 9 450 1650 442.00 1659.00 2989 1776 8.932627 3.155 -20.9 -10 1552.5 < 1900 ok
8 -81 22 1650 1650 1569.00 1672.00 1862 1763 3.466113 3.109 -13.0 -10 1560.4 < 1900 ok
9 -165 -28 2850 1650 2685.00 1622.00 746 1813 0.556143 3.287 -5.2 -10 1567.9 < 1900 ok
10 30 29 4050 1650 4080.00 1679.00 -649 1756 0.421526 3.084 4.5 -10 1578.0 < 1900 ok
11 113 77 5250 1650 5363.00 1727.00 -1932 1708 3.73359 2.918 13.5 -10 1587.2 < 1900 ok
12 -2 -71 6450 1650 6448.00 1579.00 -3017 1856 9.103798 3.445 21.1 -10 1593.9 < 1900 ok
13 -115 -30 450 2850 335.00 2820.00 3096 615 9.583668 0.378 -21.6 -3 1558.3 < 1900 ok
14 -80 8 1650 2850 1570.00 2858.00 1861 577 3.462391 0.333 -13.0 -3 1567.1 < 1900 ok
15 15 -82 2850 2850 2865.00 2768.00 566 667 0.320073 0.445 -3.9 -4 1575.6 < 1900 ok
16 102 53 4050 2850 4152.00 2903.00 -721 532 0.520202 0.283 5.0 -3 1585.4 < 1900 ok
17 138 5 5250 2850 5388.00 2855.00 -1957 580 3.830828 0.337 13.7 -3 1593.7 < 1900 ok
18 134 30 6450 2850 6584.00 2880.00 -3153 555 9.942986 0.308 22.0 -3 1602.2 < 1900 ok
19 -34 -49 450 4050 416.00 4001.00 3015 -566 9.088718 0.320 -21.0 3 1565.5 < 1900 ok
20 30 20 1650 4050 1680.00 4070.00 1751 -635 3.065126 0.403 -12.2 4 1574.7 < 1900 ok
21 39 27 2850 4050 2889.00 4077.00 542 -642 0.293493 0.412 -3.8 4 1583.2 < 1900 ok
22 -112 -113 4050 4050 3938.00 3937.00 -507 -502 0.257303 0.252 3.5 3 1589.7 < 1900 ok
23 -334 24 5250 4050 4916.00 4074.00 -1485 -639 2.205968 0.408 10.4 4 1597.3 < 1900 ok
24 125 18 6450 4050 6575.00 4068.00 -3144 -633 9.886308 0.401 21.9 4 1608.8 < 1900 ok
25 -55 -72 450 5250 395.00 5178.00 3036 -1743 9.215778 3.038 -21.2 10 1572.0 < 1900 ok
26 -106 -9 1650 5250 1544.00 5241.00 1887 -1806 3.559826 3.261 -13.2 10 1580.3 < 1900 ok
27 19 -60 2850 5250 2869.00 5190.00 562 -1755 0.315563 3.080 -3.9 10 1589.3 < 1900 ok
28 -33 -34 4050 5250 4017.00 5216.00 -586 -1781 0.343689 3.171 4.1 10 1597.4 < 1900 ok
29 41 17 5250 5250 5291.00 5267.00 -1860 -1832 3.46053 3.356 13.0 10 1606.6 < 1900 ok
30 5 -65 6450 5250 6455.00 5185.00 -3024 -1750 9.146088 3.062 21.1 10 1614.3 < 1900 ok
31 -19 8 450 6450 431.00 6458.00 3000 -3023 8.9985 9.138 -20.9 17 1579.4 < 1900 ok
32 -97 -25 1650 6450 1553.00 6425.00 1878 -2990 3.525945 8.939 -13.1 17 1587.1 < 1900 ok
33 -79 -54 2850 6450 2771.00 6396.00 660 -2961 0.43527 8.767 -4.6 17 1595.4 < 1900 ok
34 -121 -19 4050 6450 3929.00 6431.00 -498 -2996 0.248253 8.975 3.5 17 1603.7 < 1900 ok
35 46 5 5250 6450 5296.00 6455.00 -1865 -3020 3.479158 9.120 13.0 17 1613.3 < 1900 ok
36 107 -20 6450 6450 6557.00 6430.00 -3126 -2995 9.773439 8.969 21.8 17 1622.0 < 1900 ok

Sum -693 -535 124200 124200 123507.00 123665.00 157.2325 150.564


Effective CG of Group -19.3 -14.9 3450.0 3450.0 3430.8 3435.1 (3) (4)
-19.3 -14.9 -6.97852 -5.62605459
eyy exx 𝑁. 𝑒𝑦𝑦 𝑁. 𝑒𝑥𝑥
𝐼𝑦𝑦 𝐼𝑥𝑥
Outcome: Pile group ecc is within tolerance of 75mm in both x and y directions. 28/7/2021