In table no.4 these are Deflection at each story in z direction, as [3] Saurabh Kawale, Dr. S.V.

V. Joshi, Department of Civil


height increases wind load increases and defection at storey Engineering “Analysis of High-Rise Building for Wind
increases comparison of deflection as per IS 875 – 1987 and as Load” International Journal for Scientific Research &
per IS 875 – 2015 mention in above table in z direction. Development| Vol. 5, Issue 03, 2017 | ISSN (online): 2321-
0613.
Conclusion
[4] Thejaswini, Dr sawjanya, Department of Civil
 The maximum deflection in the top most storey is Engineering “comparitive study of old or new code for high
22.196 mm for structure which is designed as per Rise Building for Wind Load” International Journal for
Old IS code and 17.174 mm in case of structure Scientific Research & Development| Vol. 7, Issue 11, Nov
which is designed as per new IS Code in x dir. 2018 | ISSN (online): 2278-0181.
 The maximum deflection in the top most storey is
28.143 mm for structure which is designed as per
[6] Prof. Sarita Singla, Taranjeet Kaur, Megha Kalra and
Old IS code and 20.864 mm in case of structure
which is designed as per new IS Code in z dir. Sanket Sharma, Civil Engineering Department, Chandigarh,
 Wind force has been decreased as per the new code India. “Behaviour of R.C.C. Tall Buildings Having Different
[IS: 875 (Part 3) 2015]. Percentage decreased is Shapes Subjected to Wind Load”. Conf. on Advances in Civil
15.56% along “X” direction and 18.87% along “Y” Engineering 2012 DOI: 02. AETACE.2012.3.17.
direction.
 Displacement for the top most storey of G+11 [7] B. S. Mashalkar “Effect of Plan Shapes on the Response
storey building as per new code 22.62% as been
of Buildings Subjected to Wind Vibrations” IOSR Journal of
decreased along “X” direction and along “Z”
direction as per new code 25.86% as been decrease Mechanical and Civil Engineering (IOSR-JMCE) e-ISSN:
in new code when compared with old code. 2278-1684, p-ISSN:2320-334X PP80-89.
 Storey drift for the top most storey of G+11 storey
building as per new code 6.37% along “X” direction [8]. Megha Kalra, Purnima Bajpai and Dilpreet Singh. Effect
as been decreased and along “Y” direction as per of Wind on MultiStorey Buildings of Different Shapes Indian
new code 27.09% as been decreased in new code Journal of Science and Technology, Vol 9(48),
when compared with old code.
DOI:10.17485/ijst/2016/v9i48/10570, December 2016.
 From the above results it can be concluded that new
IS Code [IS: 875 – (Part 3) – 2015] will provide
high safety to the structure for static analysis as [9]. Higgins, Theodore R. 1979 “Structural Design of Tall Steel
compared to Old IS Code also structure is Buildings: Council on Tall Buildings and Urban Habitat” Vol.
economical that designed as per [IS: 875 – (Part 3) Sb. American Society of Civil Engineers.
– 2015].
 Lateral deflection at each storey shall not exceed [10]. Vikrant Trivedi“Wind Analysis and Design of
0.002 times the storey height and all the lateral G+11Storied Building Using STAAD-Pro” International
displacement at each story is under permissible Research Journal of Engineering and Technology (IRJET) e-
limit. ISSN: 2395-0056 Volume: 05 Issue: 03 Mar-2018.

[10]. Md Ahesan, M d Hameed “Comparative Study on Wind


References Load Analysis Using Different Standards” Vol.7, Special Issue
3, March 2018.

[1]. Is 875: (1987) part3 Indian Standards Code of Practice for [11].Alkesh Bhalerao (2016)“Effect of structural shape on
Design Loads for Buildings and Structures Part.3 - Wind Loads. wind analysis of multi storied RCC structures”.
Bureau of Indian Standards, India.
[12]. Shaikh Muffassir (2016) “Comparative Study on Wind
[2]. Is 875: (2015) part3 Indian Standards Code of Practice for
Analysis of Multi-story RCC and Composite Structure for
Design Loads for Buildings and Structures Part.3 - Wind Loads. Different Plan Configuration”.
Bureau of Indian Standards, India.