International Journal of Chemical and Biological Engineering 4:1 2011
pores. Consequently, the Knudsen and viscous flow diffusion temperature polarization [13]-[15], [17], [18].
should be a chosen as more appropriated [13]-[15]. Heat transfer across the boundary layers in a MD module is
The model suggests a linear relationship between the water often the rate limiting step for mass transfer, because such a
flux, N, and the water vapor pressure difference between large quantity of heat must be supplied to the vapor liquid
evaporating and condensing surface. interface to vaporize the liquid. The heat transfer coefficient
of the VMD feed side boundary layer, hf, is defined by [8]:
N = K M Δ PV = K M ( PV − P0 ) (1)
Q = h f Δ T f
(4)
Where Km is called MD coefficient, P0 is the pressure in the
vacuum side and Pv is the water vapor pressure in the Where Q is the rate of heat transfer across the boundary layer
membrane surface at the temperature Tw. Coefficient Km and ∆Tf is the temperature drop across the boundary layer. In
depends on temperature as well as on some geometric VMD, the conductive heat transfer across the membrane is
characteristics of the membrane. Based on the Kinetic Theory negligible because of the low pressure on the permeate side of
of Gases or the Dusty Gas Model, suggest that there is a the membrane [8], [13]; therefore, the heat transferred through
Knudsen type diffusion of water molecules through the the liquid boundary layer and the energy transported through
membrane pores and the permeation flux, N, was written [13], the membrane for VMD [8], [12]:
[15], [16]:
1
hf ΔT f = N ΔH V
(5)
rε ⎛ M ⎞ 2
Δ PV (2)
N = 1 .0 6 3 8
τ ⎜⎝ R T ⎟⎠ δ
where ∆Hv is the latent heat of vaporization of water.
The empirical correlation like a Dittus-Boelter equation
Where r is the pore size, ε is the fractional void volume of the gives the value of hf for turbulent liquid flow written in the
membrane, δ is the membrane thickness, τ is the pore simplified form [8]:
tortuosity, M is the water molecular mass and R is the gas
constant.
hd = N u = a R eb Prc (6)
As it is well known, the water vapor pressure at liquid – kT
vapor interface (in Pa) may be related with the temperature (in
K), by using the Antoine’s equation [12]: Where d is the effective tube diameter, kT is the thermal
conductivity of the water, Nu, Re and Pr are the Nusselt,
PV = e x p ( 2 3 . 1 9 6 4 −
3 8 1 6 .4 4
) (3) Reynolds and Prandtl numbers respectively, and a, b and c are
− 4 6 .1 3 + T characteristic constants of the module design and liquid flow
regimes. The viscosity correction factor normally associated
VMD is a thermally driven process, heat and mass transfer with the Dittus-Boelter equation (μ / μwall)0.14, is negligible for
are involved simultaneously and boundary layers are formed MD application [8].
near the membrane surface. Consequently, there is a decrease When both heat and mass transfer are occurring
of the driving force due to polarization effects of both simultaneously, the mass and heat transfer coefficients may be
temperature and concentrations [6]. When a molecular related by the Reynolds analogy [19].
mixture is brought to the membrane surface by the driving
force action, some molecules will permeate through the 2
8
International Journal of Chemical and Biological Engineering 4:1 2011
measured by the Rotameter connected in between the pump experimental values of the MD flux as function of the water
and module. A vacuum pump was connected to the permeate flow rate, with the water inlet temperature as parameter. The
side of the membrane module to remove the water vapor flux. feed flow rate was varied between 30 and 54 l/h for each one
Cold trap was used to condense and recover the water of the following water inlet temperature: 313, 323 and 333 K.
permeating vapor. The condensed pure water was collected to The Reynolds’s numbers range from 14521 to 26363. In this
calculate the distillate flux. Calibrated vacuum gauge was case, the MD flux increases with the feed flow rate because of
used to measure the pressure at the permeate side of the increased Re and decreased boundary layer resistances. At
module. A schematic view of the setup is presented in Fig. 1. higher Re, high heat transfers from the bulk feed to the
The feed temperature and feed flow rate was varied membrane surface approaches to the corresponding
respectively between 40 and 60 0C, and 30 and 54 l/h. The temperature in the bulk phases leading to grater MD flux.
vacuum pressure was kept 3 kPa in all the experiment. The
process was allowed to run for approximately 1 to 2 h.
h)
11 T = 313 K
2
TABLE I T = 323 K
11 30 l/h
2
Pearmeate flux (Kg/m
9 42 l/h
54 l/h
7
3
1
310 315 320 325 330 335
Tem perature (K)
Fig. 3 Effect of feed temperature at feed salt conc. = 30000 mg/l, and
Fig. 1 Experimental setup
permeate Pressure = 3 kPa.
9
International Journal of Chemical and Biological Engineering 4:1 2011
hf (W / m 2 K)
2
313 K 8000
1.95 323 K
333 K 6000
1.9
4000
log (Nu)
1.85
2000
1.8
0
1.75 0 20 40 60 80 100
0
1.7 Bulk feed tem eprature ( C)
4.1 4.2 4.3 4.4 4.5 Fig. 6 Heat transfer coefficient, hf, is a function of bulk feed
log (Re) temperature at feed flow rate = 54 l/h
Fig. 4 log (Nu) versus log (Re) at constant feed inlet temperature,
The (8) was simplified and calculated the heat transfer
feed flow rate = 54 l/h, Permeate pressure = 3 kPa, and feed salt
conc. = 30000 mg/l. coefficient is a linear function of feed temperature. Fig. 6
shows a graph of the heat transfer coefficient over a 0 to 100
0
The heat transfer coefficient associate with each of the data C temperature range at 54 l/h feed flow rate and for 30000
points was measured and the dimensionless Re and Nu were mg/l of salt concentration in feed water. Additionally, the
calculated from the solution properties. Fig. 4 shows the simplified mass transfer coefficient, kf, equation was
results as a log-log plot of Nu Versus Re is made to estimate developed by using the heat-mass transfer analogy as shown
the dependence of the heat transfer coefficient on the Re, that in Fig. 7. The following simplified equations (9), (10) of heat
is, on the water feed flow rate. These results were used to and mass transfer are formed, which are used frequently for
evaluate the empirical constants b in the heat transfer VMD system (Tf is in 0C):
correlation (6). This plot is made for each water inlet
temperature, so the influence of the Pr will be small. The best h f = 3912 + 84.92T f (9)
fit line slope is 0.71 + 0.09 which agrees with the Dittus-
Boelter value of 0.8. Thus, in the VMD experiments, the k f = 1.162 + 0.3352T f (10)
Dittus – Boelter value of b = 0.8 is applicable to this work.
40
-1.52
35
0.4 0.45 0.5 0.55 0.6
30 kf = 1.162 + 0.3352 Tf
-1.54
log (Nu / Re0.8)
25
k f (m/s)
-1.56 20
15
-1.58
10
-1.6 5
log (pr)
0
0.8 0 20 40 60 80 100
Fig. 5 log (Nu /Re ) versus log (Pr)
Bulk feed tem perature (0C)
In the Fig. 5, a plot of log (Nu / Reb) versus log (Pr) was Fig.7. Mass transfer coefficient, kf, is a function of bulk feed
made on to estimated the empirical constant a and c of (6). temperature at feed flow rate = 54 l/h
The best fit line slope is 0.30 + 0.06 and the intercept gives a
value of 0.019 + 0.008 which corresponds well with the Attention would be better focused on designing VMD
Dittus-Boelter value of a = 0.023 and c = 0.33. Hence, the module to provide high heat transfer coefficient practically, if
experimentally determined empirical constants did not deviate VMD has been used for desalination, it will be operated at low
significantly from their Dittus-Boelter values. Thus, (6) can be pressures with good membrane permeability to maximize the
re-written as: flux. Therefore, the process will be heat transfer limited. So
10
International Journal of Chemical and Biological Engineering 4:1 2011
maximizing the heat transfer coefficient by a good module provide the high heat transfer coefficient for maximize the
design maximizes the mass flux. mass flux of distilled water.
The effect of boundary layer heat transfer resistance relative MD flux is strongly dependent on the water feed flow rate
to the total heat transfer resistance of the system is given by and feed inlet temperature. An increase in the water feed flow
the (11) of temperature polarization coefficient, θ: rate and temperature is a accompanied by an increase in the
MD flux and corresponding increase in the heat transfer
θ = (T f − T fm ) (T f − TV ) (11) coefficient in the water feed boundary layer. This can be
attributed reduction in the temperature polarization effect.
Also, the study undertaken of the effect of bulk feed
where Tf is the bulk feed temperature, Tfm is the feed side
temperature on the temperature polarization factor and found
membrane surface temperature, and Tv is the vacuum side
it increase with increase in bulk feed temperature. Hence, the
temperature. The concept of the temperature polarization
polarization factor is a major tool for VMD process behavior.
factor will be used as a tool for evaluating the effect of the
input parameters on maximizing the mass flux. When, the
ACKNOWLEDGMENT
value of θ approaches zero for systems, Tf → Tfm and the
process is limited by mass transfer through the membrane and We are deeply indebted to University of Pune, Pune for the
resistance in the liquid phase is negligible. When θ → 1, Tfm financial support for this research work and also the faculty of
→ Tv so the resistance in the membrane is negligible and the Chemical Engineering Department and management of Sir
process is limited by heat transfer to the membrane surface Visvesvaraya Institute of Technology, Nashik, for the constant
[18]. The calculated value of θ as a function of feed bulk support during the work. We are especially thankful to Prof.
temperature is shown in Fig. 8. The results indicate that θ S.G. Wakchaure for his support during the fabrication of
increases by increasing bulk feed temperature. Since experimental setup.
increasing the bulk feed temperature increases the mass flux
that requires sufficient heat of vaporization providing such a REFERENCES
heat increases the difference between the Tf and Tfm, and in [1] Drioli E., and Wu Y., “Membrane desalination an experimental study,”
Desalination, vol. 53, 1985, pp. 339-346.
turn the polarization factor. It is important to keep θ as small [2] Sarti G.C., Gostoli C., and Matulli S., “Low energy cost desalination
as possible. process using hydrophobic membranes,” Desalination, vol. 56, 1985, pp.
277-286.
0.25 [3] Kubota S., Ohta K., Hayano I., Hirai M., Kikuchi K., and Murayama Y.,
“Experiments on sea water desalination by membrane distillation,”
temperature polarization
11
International Journal of Chemical and Biological Engineering 4:1 2011
[16] E.A. Mason, A.P. Malinauskas, “Gas transport in porous media: The
Dusty Gas Model,” Elsevier, Amsterdam, 1983, PP. 30-42.
[17] L.Martinez-Diez, M.I. Vazquez-Gonzalez, “Temperature polarization in
mass transport through hydrophobic porous membranes,” AIChE J. vol.
42, 1996, pp. 1844-1852.
[18] S. Bandini, C. Gostoli, G.C. Sarti, “Separation efficiency in vacuum
membrane distillation,” J. Membr. Sci., vol. 73, 1992, pp. 217-229.
12