GENERAL PARAMETERS
fc' 28 β 0.85
fy 414 Es 200000
transverse: ties Ec 24870.06
CONCRETE SECTION:
B (dim. Along X) 450
H (dim. Along Y) 700
LONGITUDINAL REBARS:
2
LINE y (mm) n Db (mm) AS (mm )
1 75 4 25 1963.50
2 250 2 25 981.75
3 400 2 25 981.75
4 575 4 25 1963.50
5
6
7
8
9
10
2
TOTAL 5890.49 mm
ρ 0.0187 OKAY!
ρmin 0.01
ρmax 0.06
5000.0
4000.0
3000.0
2000.0
1000.0
0.0
0.0 100.0 200.0 300.0 400.0 500.0 600.0 700.0 800.0 900.0
-1000.0
-2000.0
COLUMN INTERACTION DIAGRAMS for C1
GENERAL PARAMETERS
fc' 28 β 0.85
fy 414 Es 200000
transverse: ties Ec 24870.06
CONCRETE SECTION:
B (dim. Along Y) 700
H (dim. Along X) 450
LONGITUDINAL REBARS
2
LINE y (mm) n Db (mm) AS (mm )
1 75 4 25 1963.50
2 175 2 25 981.75
3 275 2 25 981.75
4 375 4 25 1963.50
5
6
7
8
9
10
TOTAL 5890.49
ρ 0.0187 OKAY!
ρmin 0.01
ρmax 0.06
5000.0
4000.0
3000.0
2000.0
1000.0
0.0
0.0 100.0 200.0 300.0 400.0 500.0 600.0
-1000.0
-2000.0
SHEAR ANALYSYS for C1
GENERAL PARAMETERS
fc' 28 Ø 0.75
fyv 276 Es 200000
transverse: ties Ec 24870.06
CONCRETE SECTION:
B (dim. Along X) 450
H (dim. Along Y) 700 D 636 mm
USE S = 175.00 mm
CONCLUSION:
USE THE FOLLOWING SPACING :
2 @ 50 mm
: CONFINEMENT TIES
6 @ 100 mm