Multimeter Current Clamp: (Code: M80430)
Multimeter Current Clamp: (Code: M80430)
CPM
(Code: M80430)
INSTRUCTION MANUAL
( M98111201-03-10A )
CIRCUTOR S.A.
--------- MULTIMETER CURRENT CLAMP CPM -------- PG No. 1
-
SAFETY NOTES
Before using the equipment please read the user manual, paying special attention to
the SAFETY REQUIREMENTS section.
The symbol on the equipment means "CONSULT THE INSTRUCTION
MANUAL". It can also appear as a symbol of warning or caution in this manual.
WARNING and CAUTION statements can appear throughout this manual to avoid
hazard to persons or damage to equipment or other property.
1.- OVERVIEW
1.1.- Description
The CPM Current clamp provides functions for the measurement of voltage,
current, resistance, continuity sound alarm, diode test, as well as frequency
measurement.
Three push buttons allow for the selection of functions such as measurement
hold (HOLD), maximum value (MAX) and reset for current measurement DC (DCA
ZERO).
--------- MULTIMETER CURRENT CLAMP CPM -------- PG No. 2
-
The analyzer is powered by a 9 V battery. Its design and its double insulation
makes the CPM a robust and secure instrument.
--------- MULTIMETER CURRENT CLAMP CPM -------- PG No. 3
-
1.2.- Specifications
Display functions
Hold Measurement value hold.
MAX Maximum measurement value hold.
Zero Automatic
Environmental conditions
Operating temperature 0 °C to 40 °C (H.R. 0-70%)
Storage temperature 20 °C to 60 °C, (H.R. 0-80%) with the
battery removed
DC Voltage
Range 600 V
Accuracy ± (0.5% read. + 1 digit)
Input impedance 10 MΩ
Overload protection 600 V DC or AC rms
Resistance
Ranges 2 kΩ, 200 kΩ
Accuracy ± (1.2% read. + 1 digit)
Open circuit voltage 0.3 V DC
Overload protection 600 V DC or AC rms
Frequency (Autoranging)
Ranges 2 kHz, 20 kHz
Accuracy ± 0.1% read. + 3 digits.
Sensitivity 80 V rms minimum
Overload protection 600 V DC or AC rms
--------- MULTIMETER CURRENT CLAMP CPM -------- PG No. 6
-
Continuity
Sound alarm Less than 30Ω in the range of 2kΩ.
Overload protection 600 V DC or AC rms
Diode test
Test current 1.0 mA ± 0.6 mA
Accuracy ± (6.0% read. + 3 digits)
Open circuit tension 3.0 V DC typically
Sound alarm < 30 mV
Overload protection 600 V DC or AC rms
2.1.- General
This equipment can be used in environments of Pollution Degree 2.
Overvoltage Category: See sections 2.2 and 2.3.
In order to ensure safety only the following specified types of the accessories
must be used:
Test probes:
Always keep the specified ranges in mind for both power supply and
measurement.
Obey the maximum environmental conditions specified for the apparatus at
all times.
Remember that voltages higher than 60 V DC or 30 V AC rms are potentially
dangerous.
The operator is only authorized to intervene for: Battery replacement
Specific instructions for these interventions are defined in the Maintenance
section.
Any other change made to the equipment must be done exclusively by
specialized personnel.
Strictly follow the cleaning recommendations that are described in the
Maintenance section.
--------- MULTIMETER CURRENT CLAMP CPM -------- PG No. 9
-
Symbols:
Protection terminal
Shell terminal
Equipotentiality
Start
Stop
--------- MULTIMETER CURRENT CLAMP CPM -------- PG No. 10
-
B
--------- MULTIMETER CURRENT CLAMP CPM -------- PG No. 12
-
[4] COM common input terminal for test probes for all measurements.
[6] DISPLAY
Display of measured values and operating mode
3.2.- Use
ATTENTION
When the value to be measured is unknown always place the rotary switch to the
highest range and reduce it progressively in function of the value in question.
4.- MAINTENANCE
Attention : Disconnect the test probes before changing the battery or performing
any maintenance service.
Caution : To clean the case, make sure that the equipment is disconnected.
--------- MULTIMETER CURRENT CLAMP CPM -------- PG No. 19
-
Clean the case periodically with a soft cloth moistened with water and
detergent. Do not use abrasives or solvents. Dry thoroughly before reusing the
equipment.