M03-08-2021 - Nivel Ii - Lado A

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 13

______________________________________________________________________________

blank
blank
NIVEL II - LADO A
blank
HOTEL ALOFT
SAN PEDRO SULA 7 CALLE S, 18 AVE S.O.
blank
Tel:
Fax:
8/3/2021 V1.9.10

______________________________________________________________________________________________________________
The CIAC Project Express is property of CIAC. Only the data published in the official documents is exactly correct.All the data used in this program
is just for your information. 1
______________________________________________________________________________

1. Material List
.

Rated Total
Unit Sum Cooling Cooling
Picture Model Memo Unit Qty. Power Type
Price($) Price($) Capacity Capacity
(Btu/h) (Btu/h)

1Φ,220-
CC43BV056LL
Indoor unit set 9 0 0 230V,50/60 19100 171900
YJ1H
Hz

1Φ,220-
CC43BV045LL
Indoor unit set 5 0 0 230V,50/60 15400 77000
YJ1H
Hz

1Φ,220-
CC43BV112H
Indoor unit set 2 0 0 230V,50/60 38200 76400
HYJ1H
Hz

CA43CV450- Outdoor 3Φ,208-


set 1 0 0 153600 153600
V5J1H Unit 230V,60Hz

CA43CV400- Outdoor 3Φ,208-


set 1 0 0 136500 136500
V5J1H Unit 230V,60Hz

Branch
FQG-B1350A set 1 0 0 0 0
Pipe

Branch
FQG-B730A set 2 0 0 0 0
Pipe

Branch
FQG-B506A set 2 0 0 0 0
Pipe

______________________________________________________________________________________________________________
The CIAC Project Express is property of CIAC. Only the data published in the official documents is exactly correct.All the data used in this program
is just for your information. 2
______________________________________________________________________________

Rated Total
Unit Sum Cooling Cooling
Picture Model Memo Unit Qty. Power Type
Price($) Price($) Capacity Capacity
(Btu/h) (Btu/h)

Branch
FQG-B335A set 10 0 0 0 0
Pipe

HZG-20B Gather Pipe set 1 0 0 0 0

Copper
Pipe-1-1/8" m 7.3 0 0 0 0
Pipe

Copper
Pipe-1/2" m 61.5 0 0 0 0
Pipe

Copper
Pipe-1" m 1 0 0 0 0
Pipe

Copper
Pipe-1-1/4" m 30 0 0 0 0
Pipe

Copper
Pipe-3/4" m 34.65 0 0 0 0
Pipe

Copper
Pipe-5/8" m 22.75 0 0 0 0
Pipe

______________________________________________________________________________________________________________
The CIAC Project Express is property of CIAC. Only the data published in the official documents is exactly correct.All the data used in this program
is just for your information. 3
______________________________________________________________________________

Rated Total
Unit Sum Cooling Cooling
Picture Model Memo Unit Qty. Power Type
Price($) Price($) Capacity Capacity
(Btu/h) (Btu/h)

Copper
Pipe-7/8" m 15.1 0 0 0 0
Pipe

Copper
Pipe-3/8" m 38 0 0 0 0
Pipe

Copper
Pipe-1/4" m 57.7 0 0 0 0
Pipe

R410A Refrigerant Kg 18 0 0 0 0

IDU:
325200
Total 0 ODU:
290100

______________________________________________________________________________________________________________
The CIAC Project Express is property of CIAC. Only the data published in the official documents is exactly correct.All the data used in this program
is just for your information. 4
______________________________________________________________________________

2. Room List
.
Cooling Design Load Cooling Actual Load
Heating(Actual/ Airflow(Actual/
Name Area(m²) Type (Sensible/Total)(Btu/h (Sensible/Total)(Btu/h Qty.
Design)(Btu/h) Design)(CFM)
) )

______________________________________________________________________________________________________________
The CIAC Project Express is property of CIAC. Only the data published in the official documents is exactly correct.All the data used in this program
is just for your information. 5
______________________________________________________________________________

3. System Construction
3.1 System1--LADO A
3.1.1 ODU

CA43CV850-V5J1H Running Condition


Max. Combination 120%
Temperature

Actual Combination 112% Cooling Heating

Cooling Capacity 318000/29010


Ind.WB 19°C Ind.DB 20°C
(Corrected/Rated) 0Btu/h

Heating Capacity 309000/32420


Out.DB 0°C Out.WB 0°C
(Corrected/Rated) 0Btu/h

3Φ,208-
Power Supply 230V,60Hz
Length And Drop

Dimensions Max.Len. 57.25m Max.Drop 0m

Width /mm

Height /mm

Depth /mm

Weight 642Kg

Picture Model Width(mm) Height(mm) Depth(mm) MCA(A) MFA(A)

CA43CV450-
1350 1690 720 71.29 228.12
V5J1H

CA43CV400-
1350 1690 720 70.68 226.16
V5J1H

______________________________________________________________________________________________________________
The CIAC Project Express is property of CIAC. Only the data published in the official documents is exactly correct.All the data used in this program
is just for your information. 6
______________________________________________________________________________

3.1.2 IDU
Cooling Heating
Capacity(Sensible/ Capacity(Corr Size_WDH Weight MCA( MFA
Picture Name Model Controller Room
Corrected/Rated) ected/Rated) (mm) (Kg) A) (A)
(Btu/h) (Btu/h)

CC43BV05 12600/20100/191 1170*420*


IDU014 20100/21500 22.2 YR-E17 0.38 1.2
6LLYJ1H 00 185

CC43BV04 10900/16400/154 850*420*1


IDU013 16000/17100 18.5 YR-E17 0.59 1.88
5LLYJ1H 00 85

CC43BV05 12600/20100/191 1170*420*


IDU012 20100/21500 22.2 YR-E17 0.38 1.2
6LLYJ1H 00 185

CC43BV04 10900/16400/154 850*420*1


IDU011 16000/17100 18.5 YR-E17 0.59 1.88
5LLYJ1H 00 85

CC43BV05 12600/20100/191 1170*420*


IDU010 20100/21500 22.2 YR-E17 0.38 1.2
6LLYJ1H 00 185

CC43BV11 29400/40600/382 1350*360*


IDU009 40300/42700 62 YR-E17 3 9.6
2HHYJ1H 00 875

CC43BV05 12600/20100/191 1170*420*


IDU008 20100/21500 22.2 YR-E17 0.38 1.2
6LLYJ1H 00 185

CC43BV11 29400/40600/382 1350*360*


IDU007 40300/42700 62 YR-E17 3 9.6
2HHYJ1H 00 875

CC43BV05 12600/20100/191 1170*420*


IDU001 20100/21500 22.2 YR-E17 0.38 1.2
6LLYJ1H 00 185

______________________________________________________________________________________________________________
The CIAC Project Express is property of CIAC. Only the data published in the official documents is exactly correct.All the data used in this program
is just for your information. 7
______________________________________________________________________________

Cooling Heating
Capacity(Sensible/ Capacity(Corr Size_WDH Weight MCA( MFA
Picture Name Model Controller Room
Corrected/Rated) ected/Rated) (mm) (Kg) A) (A)
(Btu/h) (Btu/h)

CC43BV05 12600/20100/191 1170*420*


IDU002 20100/21500 22.2 YR-E17 0.38 1.2
6LLYJ1H 00 185

CC43BV04 10900/16400/154 850*420*1


IDU003 16000/17100 18.5 YR-E17 0.59 1.88
5LLYJ1H 00 85

CC43BV05 12600/20100/191 1170*420*


IDU004 20100/21500 22.2 YR-E17 0.38 1.2
6LLYJ1H 00 185

CC43BV04 10900/16400/154 850*420*1


IDU005 16000/17100 18.5 YR-E17 0.59 1.88
5LLYJ1H 00 85

CC43BV04 10900/16400/154 850*420*1


IDU006 16000/17100 18.5 YR-E17 0.59 1.88
5LLYJ1H 00 85

CC43BV05 12600/20100/191 1170*420*


IDU017 20100/21500 22.2 YR-E17 0.38 1.2
6LLYJ1H 00 185

CC43BV05 12600/20100/191 1170*420*


IDU016 20100/21500 22.2 YR-E17 0.38 1.2
6LLYJ1H 00 185

______________________________________________________________________________________________________________
The CIAC Project Express is property of CIAC. Only the data published in the official documents is exactly correct.All the data used in this program
is just for your information. 8
______________________________________________________________________________

3.1.3 Piping

______________________________________________________________________________________________________________
The CIAC Project Express is property of CIAC. Only the data published in the official documents is exactly correct.All the data used in this program
is just for your information. 9
______________________________________________________________________________

Pipes Length and Drop

Length Piping Rules Current Max


Max.Length between gather pipe and first branch pipe 30 m 130 m

Max.Length between the first branch pipe and each IDU 26.25 m 90 m

Max.Length between ODU and furthest IDU 56.25 m 220 m

Total Length of liquid pipes 134 m 1000 m

Height Piping Rules Current Max


Max.Drop between ODU and IDU(ODU higher) / 50 m

Max.Drop between ODU and IDU(IDU higher) / 40 m

Max.Drop between IDUS 0m 18 m

Max.Drop between Valve Box / /

Refrigerant Charged
Initial Refrigerant Charged(W1): 20 Kg

Additional Refrigerant Charging(W2+W3): 18 Kg

Total(W1+W2+W3): 38 Kg

______________________________________________________________________________________________________________
The CIAC Project Express is property of CIAC. Only the data published in the official documents is exactly correct.All the data used in this program
is just for your information. 10
______________________________________________________________________________

3.1.4 Wiring

______________________________________________________________________________________________________________
The CIAC Project Express is property of CIAC. Only the data published in the official documents is exactly correct.All the data used in this program
is just for your information. 11
______________________________________________________________________________

______________________________________________________________________________________________________________
The CIAC Project Express is property of CIAC. Only the data published in the official documents is exactly correct.All the data used in this program
is just for your information. 12
______________________________________________________________________________

4.Central Control

______________________________________________________________________________________________________________
The CIAC Project Express is property of CIAC. Only the data published in the official documents is exactly correct.All the data used in this program
is just for your information. 13

You might also like