Professional Documents
Culture Documents
PTK1 Oil Analysis Patch Test Kit
PTK1 Oil Analysis Patch Test Kit
HY-PRO FILTRATION
PTK1 Oil Analysis Patch Test Kit
A valuable tool for visually
analyzing contamination levels
and contaminate types in
hydraulic and lubrication systems
in the field when you need results
now.
www.hyprofiltration.com
PTK-1 Test Kit
Draw the sample fluid through the Once the entire sample has passed Place the sample (ink/dirty side up)
patch by pulling on the vacuum through the patch rinse the funnel on a clean index card and cover it
pump handle. Confirm that the waste with filtered solvent and draw immediately with a plastic laminate
bottle and funnel-patch assembly through the patch. Then separate patch cover.
are sealed. the funnel from the patch supporter
and remove the patch with forceps.
Analyze the sample with the 100x Analyze the sample with the 100x Use the reference manual photos
magnification field microscope. For magnification field microscope. For to make approximate ISO code
best results it might be necessary best results hold the light source correlation and identify contaminant
to hold the light source closer to the closer to the sample types.
sample
Bright metal particle typically from Combination bright metal, silica, Rust or gel
internal contaminant generation. rust, gel and fiber materials.
www.hyprofiltration.com