Water Wastage in RO + CATION + ANION + MB (Regenerative) : "Pure Ingenuity Delivered"
Water Wastage in RO + CATION + ANION + MB (Regenerative) : "Pure Ingenuity Delivered"
Water Wastage in RO + CATION + ANION + MB (Regenerative) : "Pure Ingenuity Delivered"
In RO + CATION + ANION + MIXED BED (Regenerative Resin), water is waster during regeneration of the
system. Per regeneration almost 36000Ltrs water is utilised (After every Five days). RO System Reject will
be 4000 Litres per operation of system.
In RO + MIXED BED (Non-Regenerative Resin), Non-regenerative resin is used in the Mixed Bed system
which does not require any water for its resins regeneration. Resin is to be directly replaced after 3 years.
RO System Reject will be 4000 Litres per operation of system.
Since the reject water from the system (as shown in above table) is to be diverted to Effluent Treatment Plant
(ETP). ETP capacity required for RO + CAT + ANI + MB (Regenerative) System will be much higher as
compared to RO+MB (Non-Regenerative) System.
It is clearly seen from the above chart that Yearly Operation cost of RO + MB (30”X75”) (Non-
Regenerative)is less than the yearly cost RO + CAT(18”X65”) + ANI (18”X65”) + MB(16”X65”)
(Regenerative) System.
RO + MB RO + CAT+ ANI + MB
(Non-Regenerative) (Regenerative)
Cost of Operation Less as compared to More as compared to
Regenerative system Non-Regenerative
system
Ease of Operation Easy as compared to Difficult as compared to
Regenerative system Non-Regenerative
system
Water Wastage in Less as compared to More as compared to
Operation Regenerative system Non-Regenerative
system
Operating Hours of More as compared to Less as compared to
System Regenerative system Non-Regenerative
(No regeneration required) system
Frequency of Resin Not required After Every Five Days
Regeneration