Maximum trap loading Minimum Trap Diameters and Drainage Fixture Unit Values

Item no. Item no.


1 32 1 1
2 38 3 2
3 51 4 3
4 76 6 4
5 102 8 5
6
7
8
9
10

11

12
13
14

15
16
17

18
19
20
21
22
23

24

25

26
27
28
29
30
Minimum Trap Diameters and Drainage Fixture Unit Values

Fixture Trap & TraDrainage Fixture Unit


Bathtubs 38 2
Bidets 38 2
Clotheswashers* 51 2
Dental units 32 1
Drinking fountains 31 1
Floor drains 51 2
Interceptor* for grease, oil, etc 51 3
Interceptor* for sand, autowash, etc 76 6
Laundry tubs 38 2
Mobile home park traps 76 6
Receptors* (floor sinks), indirect waste receptors for
refrigirators, cofee urns,w ater station 38 1
Receptors* indirect waste receptors for commercial sinks,
dishwasher, air washers, etc 51 3
Shower, single stall 51 2
Shower*, gang (one unit per head) 51

Sinks, and/ or disgwashers (residential) 51 mm min waste 38 2


Sinks, bar, commercial 51 mm min waste 38 2
Sinks, bar, private 38 mm min waste 38 1

Sinks, commercial or industrial, schools, etc., including


dishwashers,w ash up sinks, and wash fountains 50.8 mm
waste 38 3
Sink, flushing rim, clinic 76 6
Sink, service 51 3
Urinal, pedestal, trap arm only 76 6
Urinal, stall, separate trap 51 2
Urinal, wall mounted, integral trap, trap arm only 51 3

Urinal, wall mounted, blowout, integral trap, trap arm only 76 6


Urinal, wall mounted, washdown or siphon jet, integral trap,
trap arm only 51 2
Urinal, wall mounted, washout, separate trap 50.8 mm min
waste 38 2
Wash basins, in sets 38 2
Wash basin (lavatory) single 32 1
Water closet,* private installation 76 4
Water closet, public installation 76 6
Discharge Capacity

Item no. Liters per second (L/s)


1 Up to 0.47 1 unit
2 0.50 to 0.92 units
3 1 to 1.89 4 units
4 1.95 to 3.16 units