specifications are being followed and fire precautions are being observed.
A Fire Safety Inspector
B Fire Brigade
C C/MFM
D Fire Ground Commander
Fire Safety Inspector shall conduct final inspection in the establishment applying for Occupancy
Permit then shall prepare ___ using the ____.
A FALAR(fire and life safety assessment report) / FSC (fire safety checklist
B After Inspection Report / Classified Standard Checklist
C Occupancy Permit / FSC
D Inspection Order / CSC
Inspection Procedure: The Fire Safety Inspector will prepare a report of recommendation-FSIC or
notice of disapproval (NOD) which shall be submitted to the __.
A C/MFM
B FSI (Fire Safety Inspector
C CRO
D Chief, FSES
The FSI will prepare the FSIC, to be signed by ___, if said establishment has substantially complied
with the provisions of the Fire Code of the Phils. Otherwise, the FSI shall prepare NOD. Inspection
Procedure:
A C/MFM
B FSI (Fire Safety Inspector
C CRO
D Chief, FSES
Inspection Procedure: The ____ will evaluate and recommend final action, which is subject to the
approval of the ___.
A C/MFM / FSI
B Chief, FSES /
C/MFM C CRO / Chief, FSES
D FSI / Chief, FSES
Upon approval or disapproval and C/MFM issue FSIC or NOD, Through CRO, endorse to the
BO/Owner: CRO retaining how many copies of the FSIC or NOD for filing and properly maintained
for future reference?
A 5 copies
B 3 copies
C 1 copy
D 2 copies
The rate or measure of power used or consumed. It represents the equivalent heat volts and ampere
consumed by lights, appliances or motors.
A. Ampere
B. Circuit
C.Watt
D. Volts or voltage
The electrical pressure that causes the electrons to move through a conductor.
A. Ampere
B. Circuit
C. Watt
D. Volts or voltage
.Those capable to burn with extreme rapidity or from which poisonous gases or explosions are to be
expected in the event of fire classified as _______.
a)Moderate hazard
b) Low hazard
c) high hazard
d) low and moderate hazard
Flashover 1. Transition between the growth stage and fully developed stage of a compartment fire 2.
Occurs when flames flash over the entire surface of a room. 3. Occurs as a result of all the materials
in the room reaching their ignition temperatures 4. Involves all exposed combustible surfaces in the
compartment 5. Temperatures range from 900°F. – 1200°F. 6. Survivability unlikely if caught in a
flashover
Rollover/Flameover a. The ignition of combustible gases which have spread throughout the fire area
b. Differs from flashover in that only combustible gases are burning c. One reason why firefighters
stay low when entering a burning building d. Controlled by extinguishing main body of fire
Most common reason of arson cases. a. Revenge b. Profit c. Competition d. All of the foregoing
the value of physical evidence depends entirely upon the fire investigator’s efforts to maintain the
security and integrity of that physical evidence from the time of it’s subsequent examination and
testing. a. Char b. Accelerant c. Chain of Custody of physical Evidence d. Fire Pattern e. None of the
above
The process of recreating the physical scene during fire scene analysis through the removal of debris
and the replacement of contents or structural elements in their pre-fire positions. a. Fire Analysis b.
Fire Scene Reconstruction c. Chain of Custody of physical Evidence d. Fire Pattern e. None of the
above
often called inverted “Vs “are triangular patterns, wider at their base than at the top. They are almost
always displayed by lines of heat and temperature demarcation on vertical walls emanating from
floor level. They are most commonly associated with volatile fuels, such as pooled flammable or
combustible liquids or natural gas. a Inverted Cone Patterns b. Fire Scene Reconstruction c.
Movement Pattern d. Fire Pattern e. None of the above
The coordination of information derived from: The physical -marks (fire patterns) left by the fire;
The observations reported by persons who witnessed the fire or were aware of conditions present at
the time of the fire; The analysis of the physics and chemistry of fire initiation, development, and
growth as an instrument to related known or hypothesized fire conditions capable of producing those
conditions. a Investigating the Scene Alone b. Fire Scene Hazards. c Origin Determination d.
Accidental Fire Cause e. None of the above
mechanical device consisting of linkages and a horizontal bar across a door, which cause the door to
open and facilitates exit from a building, structure or facility. A. FIRE ALERTING SYSTEM B.
PANIC HARDWARE C. MEANS OF EGRESS D. AUTOMATIC FIRE SUPPRESSION SYSTEM
Refers to the normal pattern or movement of fire, smoke and fire gases within a building or structure
under natural conditions. a. Free radicals b. Pyrolysis c. Thermal balance d. Thermal imbalance
Refers to gasses liberated by heat. a. Free radicals b. Flash point c. Thermal balance d. Thermal
imbalance
Known as ignition heat, it refers to any contrivance to start a fire. a. Fuel b. Oxygen c. Heat d. None
of the foregoing
An exothermic chemical change in which a combustible material react with an oxidizing agent. a.
Thermal balance b. Thermal imbalance c. Combustion d. Oxidation
Descriptive of any material when by its nature or as a result of its reaction with other elements
promotes a rapid drop in temperature of the immediate surroundings. a. Dust b. Oxidizing c.
Pyrolysis d. Cryogenic
Excess heat energy liberated by an oxidation reaction is called ____________. a. Latent heat b. Heat
of combustion c. Specific heat d. Thermal heat
Which of the following is commonly used to put out class C Fires? a. CO2 b. Sand c. Water d.
Baking Soda
It is the amount of heat necessary to convert solid to liquid. a. Specific heat b. Latent heat c. Heat of
combustion d. Heat of fusion
Formed by the incomplete combustion of acetylene or natural cracking of hydrogen in the absence of
air. a. Carbon black b. Lamp black c. Soot d. Black bone
The burning of low grade heavy oils or resinous tarry materials with sufficient air forms lamp black
commonly known as: a. Black bone b. Used petroleum c. Soot d. Black iron
During this fire phase, the burnt inverted cone pattern or fingerprint of fire is developed. a. Incipient
phase b. Initial phase c. Free burning phase d. Smoldering phase
Phase whereby the fire can no longer support the flame and carbon monoxide builds up in volume. a.
Incipient phase b. Initial phase c. Free burning phase d. Smoldering phase
Color of the smoke produced when nitrogen product is the combustible materials being burned while
bright red flame are visible. a. Black smoke b. Heavy brown smoke c. White smoke d. Greenish
smoke
When greenish yellow flames are seen in the flame, what material is being burned? a. Petroleum
products b. Chlorine manganese c. Asphalt shingles d. Potassium
When this constitutes most of the combustible materials in the fire is produces a bright reddish
yellow flames. a. Petroleum products b. Calcium c. Asphalt shingles d. Potassium
When black smoke with red and blue-green flames is visible in the fire, it indicate that this material is
burning. a. Petroleum products b. Chlorine manganese c. Asphalt shingles d. Potassium
When potassium is used as a combustible material what would be the visible color of the flame? a.
Purple b. Violet c. Lavender d. Any of the three
Executive Order 56 – emergency hotline 911
21. When should the BFP impose administrative fines for buildings with violation? a. When during
fire safety inspection, a violation is found/ noted. b. Upon issuance of notice to comply c. When after
lapse of notice to comply and reinspection shows no compliance was effected by the owner d. There
is no administrative fine being imposed by the BFP 22. Ms. Ma. Cecilia A. Ramos, Proprietress of J-
Par Construction equested for an exemption for the installation of sprinkler system for the four storey
residential building they started to construct in October 29, 2009 or before the effectivity of the
Implementing Rules and Regulations of RA 9514. The plans and specifications of the building were
approved based on the provisions of PD 1185 or the old fire code of the Philippines where sprinkler
system for four storey residential building is not a mandatory requirement. Can the BFP grant the
request exemption of Ma. Cecilia Ramos? a. Yes, under Memorandum Circular Number 2011-06, all
residential occupancies erected or constructed before the effectivity of RA 9514, including those
buildings whose plans and specifications were approved based on the requirements of PD 1185 and
are compliant with the fire safety requirements of PD 1185 are exempted from installing sprinkler
system. b. Yes, under Section 14.0.0.4 para. B of the IRR of RA 9514, the chief, BFP is given
authority to exempt buildings erected before the effectivity of the IRR of RA 9514 which when
forced to comply will compromise the structural integrity/stability of the building. c. No, because the
BFP has not yet issued FSIC for occupancy, besides there is still time to comply with the
requirements of the new fire code of the Philippines. MC 2011-06 provides two years grace period
for these existing establishments to fully comply with the fire safety requirements and measures
under RA 9514 and its IRR. d. No, RA 9514 and its IRR do not provide any authority for the Chief
BFP to grant exemption. Further, Section 2 of RA 9514 provides that, the provisions of the Fire Code
shall apply to all persons and all private and public buildings, facilities or structures erected or
constructed before and after its effectivity. 25. RA 9514 is an act establishing a comprehensive fire
code of the Philippines repealing Presidential Decree No. 1185 . The said act is also known
as_______________. a. Fire Code of the Philippines of 2008 b. Amended Fire Code of the
Philippines of 2008 c. Comprehensive Fire Code of the Philippines of 2008 d. Repealed Fire Code of
the Philippines of 2008
In an inspection report submitted by FO3 Mahly Lito and FO3 Dinah Marunong, on their inspection
conducted at St. Therese Doctor’s Hopsital located at Parañaque City. The following violations were
reflected; Absence of standpipe system and defective fire alarm and smoke detection system. Based
on that report what should the City Fire Marshal do? a. Recommend for declaration as public
nuisance to the Chief, BFP. b. Issue Notice to Comply citing thereof the specific provision/s of the
Fire Code and its IRR violated and the specific actions/corrections that should be complied for period
of not exceeding 15 days c. Issue Notice to Correct Violations, impose administrative fines and
posting of the sign in front of the building or structure that the building is fire hazard d. Recommend
for cancellation of permit at the Department of Health
18. For purposes of determining required exits, the occupant load of business purposes shall be no
less than one (1) person per _____ square meters of gross floor area. a. 9.3 b. 9.2 c. 9.1 d. 9.4
19. According to the Implementing Rules and Regulations of the RA 9514, storage of fireworks and
other pyrotechnics shall be in accordance with RA__________. a. 7182 b. 7183 c. 7138 d. 7128 20.
What are the instances where approved supervised sprinkler system becomes mandatory for
residential occupancy? a. All residential occupancy regardless of height, occupant load and number
of accommodation shall be protected by approved supervised sprinkler system. b. All residential
buildings with three (3) storeys in height shall be provided with approved supervised sprinkler
system. c. All residential building with four storeys or more in height shall be provided with
approved supervised sprinkler system. d. none of the above.
11. Which of the following statement is true about the effect of sprinkler systems on Life Safety? a.
Preventing fire spread upwards in multistory buildings b. Fires are too small to activate the sprinkler
system c. Smoke generation reaches occupants before the sprinlkler system activates d. All of the
above
It refers to fire-rated wall with specified degree or fire resistance, built of fire-resistive materials and
usually extending from the foundation up to and through the roof a building, that is designed to limit
the spread of a fire within a structure or between adjacent structures. a. Fire Wall b. Fire Door c.
Veneer Wall d. Cantilever Walls
13. Who is responsible for the inspection of all buildings, structures, facilities and premises,
hazardous operations, storage facilities and transportation vehicles of hazardous materials and the
determination of compliance of provisions of the Fire Code of the Philippines and its IRR? a. Chief,
Fire Safety Enforcement Section b. Chief Operations c. City/Municipal Fire Marshal d. Fire Safety
Enforcer
14. After conducting Fire Safety Inspection at the University of GDM School Of Engineers, you
found that the following violations exist in the building, insufficient exit width and defective fire
alarm and smoke detection system. Given those violations, what action should you recommend to
your Fire Marshal towards the owner/ administrator of the building? a. Recommend for declaration
as Public Nuisance to the Chief BFP. b. Issue Notice to comply with the person responsible for the
violation within five (5) days from submission of the Report. c. Issue the notice correct violation
stating the specific provision/s of the Fire Code and its IRR violated and the specific
actions/corrections that should be complied for a period not exceeding fifteen days. d. Issue
abatement order to the owner, administrator or occupant of the building, structure and their premises
of facilities for a period not exceeding fifteen days.
15. A high rise building is one which the distance between the floor of the topmost storey and ground
level is _____ meters or more. a.13 b. 14 c.15 d. 20
6. It refers to the portion of a roadway or public way that should be kept open and unobstructed at all
times for the expedient conduct of fire fighting operations. a. Fire Escape b. Fire Lane c. Fire Exit d.
Fire Protective Assembly
7. Which of the phrases about Assembly Occupancies is most appropriate? a. Assembly Occupancies
include stores, markets, and other rooms buildings, or structures for the display and/ or sale of
merchandise. b. Assembly Occupancies include, but not limited to, all buildings or portions of
buildings used for gathering together of fifty (50) or more persons for such purposes as deliberation,
worship, entertainment, eating, drinking, amusement, awaiting transportation, or similar uses. c.
Assembly Occupancies include all buildings or structures utilized primarily for sheltering of goods,
merchandise, products, vehicles, or animals. d. Assembly Occupancies refer to two or more classes
of occupancies occurring/ located/situated/ existing in the same building and/or structures so
intermingled that separate safeguards are impracticable.
8. Which type of occupancy a Gasoline Station belongs?
a. Storage Occupancy
b. Industrial Occupancy
c. Miscellaneous Occupancy
d. Mercantile Occupancy
9. It refers to an act that would remove or neutralize a fire hazard. a. Fire Safety Inspection b.
Abatement c. Issuance of Notice to Comply d. Stoppage or Closure
10. It refers to alarm initiating device designed to actuate when visible or invisible products of
combustion are present in the room or space where the unit is installed? a. Fire Alarm b. Smoke
Alarm c. Smoke Detector d. Sprinkler
1. What are the four elements of fire tetrahedron? a. Oxygen, fuel, heat and self-sustained chemical
chain reaction b. Air, fuel, heat and self-sustained chemical chain reaction c. Air, fuel, gas and self-
sustained chemical chain reaction d. Oxygen, wood, heat and self-sustained chemical chain reaction
e. Oxygen, fuel, gas and self-sustained chemical chain reaction
2. It is the transfer of heat by the movement of heated fluids or gases, usually in upward direction? a.
Radiation b. Convection c. Conduction d. Friction
3. Which of the following phrases about the classification of fire is true? a. The primary mechanism
of extinguishment when dealing with Class B fires is cooling to reduce the temperature of fuel to
slow or stop the release of pyrolysis products. b. Household appliances, computers, transformers,
electric motors and overhead transmission lines are typical sources of Class C fires c. No single agent
effectively controls fire in all combustible liquids d. Either b or c
4. It is the systematic removal of heated air, smoke, and fire gases from a burning building and
replacing them with cooler air. a. Overhauling b. Rescue and Extrication c. Fire Fighting d.
Ventilation
5. Which of the following phrases is a sign of a potential backdraft? a. Pressurized smoke coming
from small cracks b. Smoke puffing at intervals from the building appearance of breathing) c.
Smoke-stained windows d. All of the above
1.It is a classification of hazard where the total amount of Class A combustibles and Class B
flammables are present in greater amounts than expected under light hazard occupancies. a. Low
Hazard b. Moderate Hazard c. High Hazard d. Extreme Hazard
2.What Mode of Heat Transfer that involves heat transfer by air motion? Convection Conduction
Radiation None of the above
3.It applies to an element of construction (a structural member, a ceiling, a partition, a door, a
window, a roof, a wall, a floor, etc…), or to an assembly of elements. Resistance to Fire Fire Load
Compartmentation Cooling Period
4.The Objective of _________________________are generally included in building design to limit
fire and smoke spread so that people have longer time to escape. a. Resistance to Fire b. Fire Load c.
Compartmentation d. Cooling Period
5.The Department of Agriculture requested Quezon City Fire District to conduct fire drill in their
office in Agham. The fire code fee assessor required them to pay 200 pesos for the fire drill.
However, DA refuse to pay the 200 pesos for the fire drill fee citing that they are government agency
and therefore exempted from paying such. Is the contention of DA proper? a. No, the Fire Code does
not provide any exemption from payment of fire code fees and taxes. Section 4 of RA 9514 provides
that the provision of the fire code apply to all persons, private and public buildings constructed and
erected before its effectivity. b. No, only public schools and local government units are exempted
from paying fire drill fee. c. Yes, government agencies are exempted from paying fire drill fee as
prescribed under Section 12.0.0.4 of the IRR of fire code of the Philippines. d. Yes, the Department
of Agriculture has autonomy and therefore may not comply with other requirements of the law.
6. After the lapse of the prescribed period to comply provided for under the notice to correct
violations. FO3 Dimalus Otan and FO3 Laging T Ama conducted a re-inspection on the apartment of
Mr Matih Gasulo located at Diliman, Quezon City. Based on their submitted re-inspection report, no
compliance was made by Mr Matih Gasulo. What should the City Fire Marshal do? a. Put up a sign
in front of the building or structure that the building is a fire hazard, impose the corresponding
administrative fines, and issue abatement order. b. Recommend the building for cancellation of its
business permit at the Business Licensing Office. c. Furnish the BFP higher office of the re-
inspection report submitted by the fire safety inspectors for their appropriate action. d. Request the
building owner to execute affidavit of undertaking specifically thereof among others the period of
completion work
1. It is the Government agency primarily responsible in the enforcement and administration of the
Fire Code of the Philippines. a. Fire Safety Practitioners b. Fire Safety Inspectors c. Bureau of Fire
Protection d. Volunteer Fire Brigade
2. The provisions of the Fire Code shall apply to: a. All persons and all public and private buildings,
facilities or structures erected and constructed before its effectivity. b. All public and private
buildings, facilities or structures erected and constructed before its effectivity. c. All persons and all
public and private buildings, facilities or structures, erected and constructed before and after its
effectivity d. None of the above
3. The following are duties and functions of the chief, BFP except. a. Issue implementing Rules and
Regulations. b. Reorganize the BFP as may be necessary and appropriate. c. Enter into the
memoranda of agreement with other departments, bureaus, agencies, offices and corporations of the
government. d. Grand exemption on the mandatory installation of AFSS to any building or structure.
4. An integrated network of hydraulically designed piping system installed in a building, structure or
facility with outlets arranged in systematic pattern. It automatically discharges water when activated
by heat or combustion products of fire. a. Fire sprinkler system b. Automatic Fire Sprinkler System c.
Approved supervised Sprinkler System d. Automatic Fire Suppression System
5. An integrated system of underground or overhead iping connected to a source or extinguishing
agent or medium, designed in accordance with fire protection engineering standard which when
actuated by its automatic detecting device suppresses fire within area protected. a. Stand pipes b.
Hose Reels c. Approved supervised Sprinkler system d. Automatic Fire Suppression System
6. The certificate being used to members of fire brigades, fire volunteers and fire safety practitioners
after completion of the mandatory training conducted by the agency. a. Certificate of completion b.
Certificate of Training c. Certificate of Competency d. Certificate of Appearance
7. He is vested with authority to approve the application for alternative and/or remedial fire safety
measures in lieu of fire safety requirements in the installation of AFSS. a. Chief, BFP b. Regional
Director c. City/ Municipal Fire Marshal d. Fire Safety Technical Committee
8. A clearance with fire safety checklist enumerating the life and fire safety requirements pursuant to
the provision of RA 9514 and its IRR issued by the BFP local offices/fire stations as a pre-requisites
to the issuance of building permit by building official. a. Fire Safety Inspection Certificate b. Fire
Safety Evaluation Clearance c. Fire Safety Clearance d. Fire Safety Checklist
9. A Certificate issued by the BFP local offices/fire stations as pre-requisite for the issuance of
Mayor’s permit, permit to operate, occupancy permit, PHILHEALTH accreditation for hospitals,
license to operate and other permits or licenses being issued by other government agencies upon
compliance of the fire safety requirements. a. Fire Safeti Inspection Certificate b. Fire Safety
Evaluation Clearance c. Fire Safety Clearance d. Fire Safety Checklist
10. Written order issued by the City/Municipal Fire Marshal to fire safety inspector to be presented to
the owner/administrator of buildings establishment prior to the conduct of inspection. a. After
Mission Report b. After inspection report c. Mission Order d. Inspection order
11. A standard form used by the BFP local offices/fire stations enumerating the life and fire safety
requirements of the buildings facilities or structures to be erected/constructed. a. After fire inspection
Report b. Notice to comply c. Fire Safety Checklist d. Notice to correct violation
12. The FSIC for business permit to operate has validity of: a. Every 31st of December b. 365 Days
c. Every Renewal of Permits or licenses d. None among the choices
13. The following statements are correct interpretation when it comes to collection and imposition of
taxes and fees, except: a. Tax is imposed for revenue while a fee is intended for regulation b. The
amount collected for a fee may not be used for any purpose except that which is intended to c. a tax
is normally paid after commencement of business while a fee is usually paid before d. Failure to pay
a tax will make business illegal, while failure to pay a fee does not make business illegal.
14.1. A fire protection System that includes elements of the building construction such as structural
protection and compartmentation to contain fire & smoke and support the smoke management
systems of the building. a. Fire Spread b. Pro-Active Fire Protection c. Compartmentation d. Cooling
Period
15.The amount of material which is able to burn and release heat and smoke. In a compartment,
limitation of fuel will help to reduce the dangers of heat and smoke. a.Fire Spread b.Fire Load
c.Compartmentation d.Cooling Period
16. It is a term that refers to the stage of fire development that involves near-simultaneous ignition of
most of the directly exposed combustible material in an enclosed area. a.Growth Phase b.Flashover
c.Stable Phase d.Cooling Period
CCDBC CCBAD CBDBB B
September 10, 2021 Nobody liked HAUGHTY Monty who kept bragging about his riches. A.
arrogant B. foolish C. respectable D. dependable
Jessica is an IRASCIBLE girl who frequently has tantrums. A. impatient B cheerful C. hot-tempered
D. jolly The IMPUDENT
child was scolded for answering back to older people. A. respectful B. honorable C. clever D. rude
The client was asked to verify the VERACITY of the statement of accounts issued. A. accuracy B.
discrepancy C. redundancy D. mistake The students were UPBRAIDED for misbehaving during
assembly. A. praised B. honored C. scolded D. stopped
The baffled owner ACQUIESCED to the worker’s demands. A. opposed B. reacted C. agreed
D. resisted
The Defense presented its case to the jury in a TRENCHANT manner. A. legalistic B. dignified
C. cautious D. vague
The plane OVERSHOT the runway and landed on a ditch. A passed through B. passed by C.
went beyond D. did not reach
The footprints were EFFACED when the floor was mopped. A. printed B. erased C. deformed
D. developed
To AUGMENT the policemen’s income the government allowed them to take part-time jobs. A.
increase B. contribute C. limit D. remove
Mindy RUMMAGED through the chest of old clothes for something usable to donate. A.
searched through B. wandered through C passed through D scattered
The Queen of the night dances VIVACIOUSLY. A. lively B. awkward C. kindly D. sweetly
For ENMITY and hate are contrary to friendship and concord. A. agreement B. mutual hatred
C. confusion D. division
The cardinal Center is filled with GARGANTUAN buildings, some having up to 50 floors. A.
crowded B. old and weak C. first class D. gigantic
A FASTIDIOUS person will never find true happiness. A. simple B. choosy C. greedy D.
contented Regina, being a child of three, is OBLIVIOUS to the world around her. A. careful B.
carefree C. aware D. unmindful
Black smoke with deep red litmus flames- are indication that the fuel used in the fire maybe tar,
plastic, rubber or petroleum products.
Greenish yellow flame- is a result when the fuel used is manganese or chlorine.
Bright reddish yellow flame-which indicates that calcium is used.
Heavy brown smoke with bright red flames- is indications that nitrogen products were used in the
fire.
White smoke with bright red flames- indicates that magnesium is used.
Black smoke with red and blue-green flames- would specify that asphalt shingles is used in the fire.
Lavender or purple flames -would show that potassium was used in the fire as fuel.
the spread of fire by the dropping or falling of burning materials. This is synonymous with "Fall
Down”. Drop down
arbonaceous material that has been burned and has a blackened appearance? Charcoal
a fire pattern on surfaces where soot has been burned away. Clean Burn
convex segments of carbonized material separated by cracks or crevasses that form on the surface of
char, forming on materials such as wood as the result of pyrolysis or burning. Char Blister
– a buoyant layer of hot gases and smoke produced by a fire in a compartment? CEILING LAYER
a fire pattern displayed on the cross section of a burned wooden structural member. Arrow pattern
the crime of maliciously and intentionally, or recklessly, starting a fire or causing an explosion.
Precise legal definitions vary among jurisdictions, wherein it is defined by statutes and judicial
decisions. Arson
1.Refers to the normal pattern or movement of fire, smoke and fire gases within a building or
structure under natural conditions. a. Free radicals b. Pyrolysis c. Thermal balance d. Thermal
imbalance
2.Usually comes in the form of combustible liquid which is a contrivance to hasten the start of fire. a.
Accelerant b. Plants c. Trailer d. Wick
3.Color of the smoke produced when nitrogen product is the combustible materials being burned
while bright red flame are visible. a. Black smoke b. Heavy brown smoke c. White smoke d.
Greenish smoke
4.All of the items below are the ways on how to prevent extension of fire except one: a.By fire-
protective devices. b.Opening of windows to allow air to come in. c.By quick extinguishment of the
fire. d.By protecting the exposed combustibles.
5.These are generally used to life flat on the roof surface so that firefighters may stand on the ladder
for roof work and the ladder will distribute their weights and help prevent sleeping A. Ladders B.
Roof ladder C. Folding ladder D. Straight ladder
6.These are equipped with portable ladders or various types and sizes. They also carry forcible entry
tools which firefighters used to gain entry into a building and to ventilate it to let out smoke. A.
Ladders B. Roof ladders C. Ladder truck D. Folding ladder
7.This is the final stage of where some activities. It is an inquiry conducted to know or determining
the origin and cause of fire. A. Pre fire planning B. Evaluation size-up C. Fire scene investigation D.
Alternative and Remedial Fire Safety Measures
8.This is the process of putting on the main body of fire by using the four general methods of fire
extinguishment A. Separation B. Colling C. Smothering D. Extinguishment
9.This is activity of restricting the fire at the place where it started. The process of preventing the fire
from extending from another section or from one section to another section of involved building. A.
Pre fire planning B. Extinguishment C. Confinement D. Exposure
10.This is activity of transferring people, livestock and property away from the building area to
minimize damage or destruction that the fire might incur in case it propagates to other adjacent
buildings A. Rescue B. Overhaul C. Evacuation D. Evaluation
2.The rate measure of power used or consumed. a. Ampere c. Watts b. Circuit d. Nota
3. The current amperes that a conductor can carry continuously w/o exceeding is temperature rating
or overheating. a. Circuit C. Open Circuit b. Ampacity D. Current
4. Electrical pressure that cause the electron to move a. Amperage c. Voltage b. Ampere d.
Resistance
5.A short length conductor used for connection between terminals or around a break in circuit a.
Junction Box c. Overload b. Outlet d. Jumper
6. Standard unit in measuring the strength of an electrical current a. Ampere c. Watts b. Circuit d.
Resistance
7. Operation of an equipment in excess in normal full load of rating or excess of greater ampacity a.
Overload c. Overcurrent b. Over plugging d. Exposed
8. The wire installation that supply electrical current a. Circuit c. closed circuit b. open circuit d.
Voltage
9. Current flowing continuously from one direction. A. Direct current c. Jumper b. Current d.
Jumper
10. Movement or flow of electricity passing through a conductor a. Current c.Outlet b. Circuit
breaker d. Nota
CCBCD AAAAA
What is the minimum width of corridors? a. 1.83 meters b. 2.00 meters c. 1. 38 meters d. 2.05 meters
4. "Class of fire involving ordinary combustible materials, such as wood, papers, cloth, "rubber, and
plastics."? a. Class B b. Class A c. Class C d. Class K
5. Maximum height of a handrail (in centimeters)? a. 86.5 centimeters b. 92.0 centimeters c. 85.6
centimeters d. 90.2 centimeters
6. A process where a piece of metal is heated prior to changing its shape and dimension? a. Post-
heating b. Pre-heating c. metal heating process d. Forging
7. Minimum width of an aisle for an educational use building (in meters)? a. 1.12 meters b. 1.20
meters c. 1.80 meters d. 1.50 meters
8. The minimum temperature at which any material gives off vapor in sufficient concentration to
form an ignitable mixture with air? a. flash point b. flash temperature c. blaze point d. combustion
peak
9. A continuous passageway for the transmission of air? a. air handling passage b. duct system c. air
line tube d. air duct passageway
10. Temperature rating at flash point? a. 37.8 degree Fahrenheit b. 38.7 degree Fahrenheit c. 38.0
degree Fahrenheit d. 36. 7 degree Fahrenheit
11. A class of fire with flammable liquid and gasses? a. Class C b. Class K c. Class A d. Class B
12. Maximum distance of travel from the high hazard area to an exit (in meters)? a. 21 meters b. 20
meters c. 23 meters d. 30 meters
13. Maximum force in kilograms required for a panic hardware (in kilograms)? a. 4 kilograms b. 7
kilograms c. 6 kilograms d. 5 kilograms
15. A continuous and unobstructed route of exit from any point in a building to a public way? a.
Unobstructed outlet b. Exit passage c. Means of access d. Means of Egress
form upward search to downward search or right to left a. spiral search method b. wheel search
method c. quadrant search method d. straight search method
A search method in which the crime scene is divided into smaller sections and team members are
assigned to search each section. Each of these sections can be subdivided into smaller sections for
smaller teams to search thoroughly. This method is applicable to wide area. a. spiral search method b.
wheel search method c. quadrant search method d. straight search method
1. RA No. 9514 also known as the- A. Revised Fire Code of the Philippines of 2007 B. Revised Fire
Code of the Philippines of7 2008 C. Revised Fire Code of the Philippines of 2009 D. Revised Fire
Code of the Philippines of 2010
2. Any liquid having a flash point at or above 37.8_C (100_F) A. Combustible Liquid B. Corrosive
Liquid C. Combustible Fiber D. Oxidizing Materials
3. It is a continuous passageway for the trasmission of air. A. Fire Door B. Fire Safety Construction
C. Public Way D. Duct System
4. Refers to a person who holds the legal right of possession or title to a building or real property. A.
Occupang B. Bed Spacer C. Owner D. Occupancy
5. It ia the active principle of burning, characterized by the heat & light of combustion. A. Fire B.
Arson C. Hazard D. None of these
Used to open up walls and ceilings, to vent windows, and to pull up roof boards or other building
materials A striking tools B prying tools C pushing/pulling tools D cutting tools
This penalty shall be imposed by the Regional Director upon the recommendation of the
City/Municipal Fire Marshal having jurisdiction thru channel. The implementation of this order may
be delegated to the Provincial/District Fire Marshal having jurisdiction. A fines B Stoppage of
Operation/Closure of Buildings C Declaration of Public Nuisance D nota
Provides life-safety protection for the firefighter for fast, reliable means of egress from a burning
multi storey structure. A personal alert device B personal aert safety system C personal escape safety
kit/system D none of the above
Rotated at 90 degrees horizontally and 240 degrees vertically with stream pattern ranges from
straight to full fog. A.BREAK SQUIRT B.SQUIRT
Has descretion on the classifications of buildings. A building official B fire safety inspectors C Fire
marshals
It is powerful that a newspaper can be read at 100 feet or 32m from the light source. -Kind of truck-
light tower truck
An alarm device that a firefighters is in trouble.This is ADSU and ADSU stand for? Automatic D-
istress SIgnal U-nit
Gloves
Fire boots
Helmet Bunker/fire
coat
Trouser
Suspendera
Responsible for the daily monitoring and inspection of all fire safety features of the building. – fire
safety personnel
CPR MEANS? Cardiopulmonary resuscitation ?
are substances that offer a very high resistance to current flow. A insulators B electrical conductors C
wiring devices D receptacles
are substances that offer a very low resistance to current flow. A insulators B electrical conductors C
wiring devices D receptacles
overcurrent protective device with a circuit opening fusible element which opens when there is an
overcurrent in the circuit. It is considered as the simplest and the most common circuit protective
device used into the house wiring connection. A circuit breaker B short circuit C fuse D ground fault
the service disconnecting means shall have a rating of not less than 40 amperes. A one circuit
installation B two circuit installation C one family dwelling D others
The service disconnecting means shall have a rating of not less than 30 amperes. A one circuit
installation B two circuit installation C one family dwelling D others
The service disconnecting means shall have a rating of not less than 15 amperes. A one circuit
installation B open circuit installation C one family dwelling
It is also required after which certificate of electrical inspection (CEI) is issued by the authority. A
installation B inspection C permit
is an act providing for a more responsive and comprehensive regulation for the practice, licensing,
and registration of electrical engineers and electricians. A PD 1096 B RA 7920 C RA 184 D b & c
only
A type of constructioon of steel, iron, concrete, or masonry construction and walls, ceiling and
permanent partitions shall be of incombustible fire-resistive construction. A type l B type ll C type lll
D type lV
No person, firm or corporation shall construct, alter, repair, convert, use, occupy, move, demolish
and add any building without a ___. A electrical permit B occupancy permit C building permit D
sanitary permit
No electrical installation, alteration and/or addition shall be connected or reconnected to any power
supply or any other source of electrical energy without a Certificate of Final Inspection/Completion
obtained from the government authority concerned. A Temporary Installation B Application for
Inspection C Certificate of Inspection D Special Permission
shall be filed with the government authority concerned before preliminary or final inspection is done.
A Temporary Installation B Application for Inspection C Certificate of Inspection D Special
Permission
Any current in excess of the rated current of an equipment or ampacity of a conductor. A over load B
over plugging C over reaction D over current
Operation of an equipment in excess of normal full load rating, or of a conductor in excess of greater
ampacity A over load B over plugging C over reaction D over current
A point on the wiring system at which current is taken to supply utilization equipment. A short
circuit B circuit breaker C outlet D jumper
When the circuit is interrupted and the current will stop flowing. A current B direct current C
alternating current D open circuit
Current which periodically reverses its direction. A current B direct current C alternating current D
open circuit
The difference between the magnitude of the sending end voltage and the receiving end voltage. A
service drop B voltage C voltage drop D current
Current is not interrupted and the flow of electricity is continuous. A branch circuit B circuit breaker
C closed circuit D open circuit
A related branch of the field of electricity devoted to the processing, communication, and storage of
information by electronic means. A engineering B electrical engineering C electronics engineering D
electrons engineerin
between the termination of an exit and a public way A exit B exit access C exit discharge D means of
egress
separated from all other spaces of bldg/structure by construction/equipment that provides a protected
path of travel to the exit discharge A exit B exit access C exit discharge D means of egress
a continous and unobstructed path of travel (either horizontal or vertical) from the remotest part of
the bldg leading to a public way. A exit B exit access C exit discharge D means of egress
Has descretion on the classifications of buildings. A building official B fire safety inspectors C Fire
marshals
This penalty shall be imposed by the Regional Director upon the recommendation of the
City/Municipal Fire Marshal having jurisdiction thru channel. The implementation of this order may
be delegated to the Provincial/District Fire Marshal having jurisdiction. A fines B Stoppage of
Operation/Closure of Buildings C Declaration of Public Nuisance D nota
Provides life-safety protection for the firefighter for fast, reliable means of egress from a burning
multi storey structure. A personal alert device B personal aert safety system C personal escape safety
kit/system D none of the above
Used to deliver impact to other tools in order to drive it into place Can also be used to deliver impact
directly to and break the door or lock to be forced A striking tools B prying tools C pushing/pulling
tools D cutting tools
Used to open up walls and ceilings, to vent windows, and to pull up roof boards or other building
materials A striking tools B prying tools C pushing/pulling tools D cutting tools
IT is the act of identifying locating and providing evident of the guilt of the accused in court. Criminal
investigation
Liquid fuel whose flash point is normal is above normal room temperature 37.8c. (100f) ex oil, crude, oil
diesel. Combustible liquid
It is a measurement use in fire of the rate at which heat is produced. Intensity of combustion