2. LV cable – DO we need size the cable for Short Circuit Withstand? 3. Conductor or Insulation which decides the current carrying capacity? 4. Earthed Grade Unearthed Grade cable? 5. What is the standard for derating under covered (removable type) trench? 6. we're FR cable will be used...any specific reson to use that cables in industrial.. 7. FRLS? 8. Oxygen Index? 9. Temp Index? 10. Armour vs Unarmoured cable? 11. How to decide no of runs 12. 3 runs of 400 Sq.mm vs 4 runs of 300 Sq.mm? 13. sheath voltage calculation, is based on voltage or based on distance. 14. Single end bonding vs Double end Bonding vs Cross Bonding 15. cable sizing for star delta feeder 16. Cable to be sized for Motor continuous current or starting current? Why? 17. mv cable specification for a transformer . what are parameters to be included since inrush comes do we need to size according to inrush 18. Is there any cautions to be taken care while cables selection depends on the circuit type AC/DC ? 19. how come length of the cable alter the voltage drop of the cable 20. subsea cable sizing calculation 21. Voltage drop limit for starting and steady state application 22. cable protection do we need to protect for overload or short circuit? 23. EMC requirements of cable? 24. why we use shelded cable earthed only one end use explain 25. Difference between solar cables vs AC cables. 26. Is there any advantage of using armouring as a earth conductor other than cost saving. 27. Size of armouring reqd in case of it is used as earth conductor. 28. Type of earthing cables to br used , cu/xlpe or cu/pvc 29. CLASSIFICATION BASED ON APPLICATION 30. what is the difference between AWG E2 and AWG E1 31. whenever we are going using MPCB/MCCB as a protecting device then we need to consider short circuit capacity criteria or not?? 32. mitigation method of EHV cable charging to eliminate cable capactiance effect of long distance cables 33. SWA OR AWA WE USE IT FOR ARMOURING , it is mentioned in code. But how to defend armouring as a earth conductor vs separate earth conductor when client asks.. 34. adiabatic condition 35. cable pulling calculations does it need to be performed for cable sizing 36. what is the effect of over sized earth conductor in the system? 37. for fuse operating motors how to calculated the max. cable size 38. Why 3.5 C cable only in <1.1 kV grade cables? 39. Why DC resistance is differ from AC Resistance? 40. Why Rdc is specified at 20 Deg C 41. What is the temp at which the resistance to be used for a. Load flow studies b. Short circuit studies c. Motor acceleration studies d. 42. can grounding configuration effect cable sizing 43.