Approval by NCRTC QR Code: National Capital Region Transport Corporation

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

100

1' 1 2 3 4 5 6 7 8 9
60500
4000 7500 7500 7500 7500 7500 7500 7500 4000
RLB45 RLB45 RLB46
Millimetres

RLB46

RTB25

RTB23
RTB30

RTB32

RTB24

RTB40

RTB12

RTB42

RTB13
RTB6

RTB7

RTB8
2200

2200
RLB1 RLB1 RLB18 RLB18A RLB18
A

RTB35

RTB37

RTB29
RTB9

RTB24A
(T.O.C) 233.7
10

4550

4550
5000
150MM THK FLOOR
0

- 50
---

600
600 DN

RLB2 RLB2 RLB19 RLB19 RLB21 RLB21


RLB26

RTB17
B
3850 3275 3275 3425 3425 3200 3200 3500 3500 3050 3425 3425 3275 3275 3850
550

2750
(T.O.C) 233.8 550

RTB52
400 RLB49

RTB48
TENTATIVE 7M HIGH POLE LOCATION

1100

1800
5000

4850

4850
RTB51

470MM DIAMETER

RTB24
RLB47 RLB16 RLB50
20600

650

RTB35
RTB25

RTB32

RTB23
RTB12

RTB13
RTB17
RTB8

RTB9
RTB30

RTB42
RTB6

RTB7

RTB40
RTB37

RTB28
550

1000

450
RLB3 RLB3 RLB20 RLB20 RLB22
500 RLB22
C

310
RLB27 200
300
RTB15

RTB15

RTB15

RTB15

RTB15

RTB15

RTB15

RTB15

RTB15
RTB15
3100

2500

2500
300
RLB4 700 RLB4

D
200

400
RTB33

RTB6

RTB31

RTB34

RTB36

RTB38

RTB10

RTB39

RTB11

RTB41

RTB12

RTB43

RTB13

RTB14
RTB7

RTB8

RTB9
1300 200 350
3450

3450
150MM THK FLOOR
RLB44 (T.O.C) 233.7 RLB44
7500

1000

3850 3275 3275 3425 3425 3200 3200 3500 3500 3200 3200 3425 3425 3275 3275 3850
3450

3450
230 995

RTB10
RTB36

RTB38

RTB39
1300

RTB9
1300
2300

E
RLB5 RLB5

RTB11

RTB12

RTB43

RTB13

RTB14
RTB41
RTB33

RTB31

RTB34
2200

2800

2800

2200
RTB6

RTB7

RTB8
RLB46
RLB45 REFER FACADE REINFORCEMENT DRAWING TYP. RLB46
RLB45
NCRTC-DM009-AYE-DUHD-ADM-M2-ST-11307

1 TERRACE LEVEL FRAMING PLAN SCHEDULE OF BEAM


11401 1 : 100 (SLAB THICKNESS SHALL BE 150mm(U.N.O))
BEAM SIZE
BEAM MARK
(WIDTH x DEAPTH)

RLB1 TO RLB5,18,19,20,21,22,26,44 400 x 600


RTB6 TO RTB15, 23,24,25
RTB27 TO RTB43

RLB16,45 & 46 RTB17 300 x 600

RLB18A,RTB24A 400 x 850

RLB49,50 & RTB48 300 x 500

RLB47 230 x 450

RTB51,52
REFERENCE DRAWINGS: ( STRUCTURE) LATEST REFERENCE DRAWINGS: ( ARCHITECTURE) LATEST 300 x 600

1. COLUMN LAYOUT PLAN DM009-AYE-DUHD-ADM-M2-ST-11001 1. BASEMENT LEVEL PLAN DM009-AYE-DUHD-ADM-M2-AR-11101


2. LAYOUT & DIMENSION DETAIL OF RAFT DM009-AYE-DUHD-ADM-M2-ST-11002 & 11003 2. GROUND FLOOR LEVEL PLAN DM009-AYE-DUHD-ADM-M2-AR-11101
3. FRAMING PLAN AT GROUND FLOOR LVL. DM009-AYE-DUHD-ADM-M2-ST-11008 3. FIRST FLOOR LEVEL PLAN DM009-AYE-DUHD-ADM-M2-AR-11111
4. FRAMING PLAN AT 1ST FLOOR LVL. DM009-AYE-DUHD-ADM-M2-ST-11101 4. 2ND FLOOR LEVEL PLAN DM009-AYE-DUHD-ADM-M2-AR-11121
5. FRAMING PLAN AT 2ND FLOOR LVL. DM009-AYE-DUHD-ADM-M2-ST-11201 5. 3RD FLOOR LEVEL PLAN DM009-AYE-DUHD-ADM-M2-AR-11121
6. FRAMING PLAN AT 3RD FLOOR LVL. DM009-AYE-DUHD-ADM-M2-ST-11301 6. TERRACE LEVEL PLAN DM009-AYE-DUHD-ADM-M2-AR-11131
7. GENERAL NOTES DM009-AYE-DUHD-ZZZ-M2-ST-11101 TO 11103 7. SECTION A-A DM009-AYE-DUHD-ADM-M2-AR-13101 4m 3m 2m 1m 0m 2m 4m

8. SECTION B-B DM009-AYE-DUHD-ADM-M2-AR-13111 Scale 1:100

NOTES: Certified that this document has been designed and checked in accordance with GC Quality Assurance Plan. Client:
QR CODE APPROVAL BY NCRTC
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS MENTIONED.
2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED.
NATIONAL CAPITAL REGION
3. ALL DATA RELATED TO PLAN AND PROFILE SHALL BE VERIFIED GC OFFICE, BELOW CWG FLYOVER AT KHEL GAON, NEW DELHI-110092, TRANSPORT CORPORATION
AT SITE AND ANY DISCREPANCY MUST BE BROUGHT TO THE TEL: +91 120 490 8800, EMAIL:DMGC@AIAIGC.COM ,WEBSITE: WWW.AIAIGC.COM
NOTICE OF THE NCRTC BEFORE EXECUTION OF WORK AT SITE. 7/6, Siri Fort Institutional Area, August Kranti Marg, New Delhi – 110049
Senior Discipline Expert Chief Discipline Expert Project Director
4. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL
RELEVANT ARCHITECTURAL, STRUCTURAL, PLUMBING & FIRE Project Title:
FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWINGS.
5. ALL DOOR/WINDOW CILL & LINTEL LEVELS ARE MEASURED NCRTC RRTS PROJECT DM-09-DDC
FROM MAIN FLOOR FINISHED LEVELS. R04 07-07-2021 AS PER ARCHITECTURE O.P L.J P.B Drawing Title: Project Stage:

R03 15-03-2021 BEAMS & CUTOUTS REVISED SAI L.J P.B


Certified that this document has been designed and checked in accordance with DDC Quality Assurance Plan.
Designer:
DUHAI DEPOT-ADMIN BUILDING CRD
R02 12-02-2021 BEAM SIZES REVISED SAI L.J P.B
TERRACE LEVEL FRAMING PLAN
R01 16-01-2021 REVISED DUE TO CHANGE IN LAYOUT D.R L.J P.B Paper Size: Discipline: Date: Scale:

R00 12-01-2021 FIRST SUBMISSION D.R L.J P.B D-99, 3rd Floor ,Sector 2, Noida - 201301 (U.P) A1 STRUCTURE 07/07/21 1 : 100
Designed: Drawn: Checked: Approved: Drawing: Revision:
QR Code allows verification of
REV DATE DESCRIPTION Originator Checked Approved drawings through WRENCH M.Z O.P L.J P.B NCRTC-DM009-AYE-DUHD-ADM-M2-ST-11401 R04

You might also like