Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

NOTE :-

1. FOR GENERAL NOTES REFER DRG. NO. 000M/WD/ST/001

2. ALL DIMENSIONS ARE IN MILLIMETERS.

3. REINFORCEMENT SHALL BE INSPECTED AND APPROVED


BY THE CONSULTING ENGINEERS BEFORE CONCRETING.

4. MINIMUM LAP AND ANCHORAGE LENGTH IN REINFORCEMENT


TO BE 52 x SMALLER BAR DIAMETER.

5. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH


ALL RELEVANT STRUCTURAL,ARCHITECTURAL,SERVICE&
SPECIFICATION.

6. SUBJECT TO FINALIZATION OF SLEEVES LOCATION & SIZE


SPECIAL R/F DETAIL TO BE ADDED.

7. ALL SLEEVE LOCATIONS SHALL BE INSPECTED & APPROVED


BY THE SERVICE ENGINEER BEFORE CONCERTING.

8. BAR NOTATION GIVEN IN STRUCTURAL DRAWINGS INCLUDE THE


FOLLOWING DETAILS.

5 T 10 - 06 - 150 T

Bar Location T - Top (T1 Outer, T2 Inner)


B - Bottom (B1 Outer, B2 Inner)
Bar Spacing
NF - Near Face
AA AB AC AD BD Bar Mark FF - Far Face
BF - Both Face
Bar Diameter
18000
5338 4000 6000 6000 6000 4672 Bar Type 'T' or 'R'

Number of Bars

9. CONCRETE GRADE - C30.


A1
10. COVER TO ALL REINFORCEMENT
COLUMN - 25mm
BEAM - 25mm
SLAB - 20mm

11. REFER DWG. NO. 484M/WD/ST/003 & 484M/WD/ST/004


3000

FOR GENERAL ARRANGEMENT OF FIRST FLOOR & BEAM DETAIL.

12. REFER DRG. NO. 484M/WD/ST/006 & 484M/WD/ST/005-2 FOR


STAIRCASE DETAILS & REINFORCEMENT DETAIL OF FIRST
FLOOR SLAB.

A2

D1

DD
D4
600

600
600

CD

DA
1300

EA
E2
39T10-01-150-B1

E2
CA

5
(30) 55T10-05-150-B1(25)

6
4

7
8
9
10
11
39T10-04-150-B1

12
13
BA

14
15
16
2

17
1

18

ED
19
20
21
22
C2
1300

C4
B2

F2
BD
AD
C2 B4

F4
9000

3000

(16)

(16)
AA

16T10-56-175-B2
1200

16T10-02-150-T1

FA
1200
1200 C1

2
1

3
A1

4
5
7

6
8
9
10
GA

11
12
13
14

15
1617
18
19
20
21
22
G2 GD
A4 HD
KEY PLAN OF G4
(16)
(16)

(16)

HA

RESTAURANT BUILDING & DECK H1

900
78T10-100-150-T1 (39) LOWER LEVEL H4

A3

100
1200
1200

16T10-114-175-T2

16T10-55-175-T2
32T10-54-175-B2
32T10-05-150-T1

1300
C1
100
64T10-50-175-B2 (16)

16T10-03-150-T1
100
3000

32T10-120-175-T2
32T10-51-175-B2

600
78T10-06-150-B1 (39)

78T10-09-150-B1 (39)
900

A4
100
600

600
(16)
(16)

(16)

(16)

(16)
32T10-121-175-T2 (16)

32T10-122-175-T2 (16)

32T10-53-175-B2 (16)
32T10-52-175-B2 (16)
(16)

(25) VARY 50T10-108-102-T1(25) VARY 78T10-41-103-T1(39) (39) (39) 107T10-104-150-T1(29)


(25) VARY 50 T10-10-150-B1(25) VARY 78T10-11-150-B1(39) (39) (39) 107T10-12-150-B1(29)
600

600

600
DATE REVISION REV.
DESIGN & BUILD CONTRACTOR

200, Nawala Road, Narahenpita


Colombo 05, Sri Lanka.
LOWER LEVEL SLAB R/F DETAIL Tel :2808835 to 2808844 Fax :2808846 & 2808847
Email : maga@maga.lk
NOTE
PROJECT
1.ALL SLAB THICKNESS ARE 125mm.UNLESS OTHERWISE STATED.
2.DISTRIBUTION BARS - T10@225T2 IN ALL EXPOSED AREAS AND WHERE PROPOSED TECH - CITY PROJECT
NECESSARY.
AT WALAHANDUWA
GALLE.
TITLE
REINFORCEMENT DETAIL OF LOWER LEVEL
RESTAURANT BUILDING - C1,C2 BLOCK
SHEET 1/02
DRAWN P. K. L. P. DRAWING NO.
M. P. S.
DESIGN QS / TD / 2021 / 138 - ST 306-1
L.G.S.J.E DATE SCALE REVISION
CHECKED
14.08.2021 1:50