IMPACT

TESTING
MACHINE

MODEL
MODEL MODEL
RI-30 (ASTM)
RI - 300 RI - 300(E)

IMPACT TESTING M/C. DIGITAL IMPACT TESTING M/C. CHARPY IMPACT TESTER
Large rectangular dial with inner scale for izod Electronic digital display. This impact tester is offered with 300
and outer scale for Charpy test, in Joules. Simlpe constructionof pendulum so that izod J energy exclusively for Charpy test
The pendulum is supported separately in two or charpy machine, machine can built at sight. confirming to ASTM E-23. This machine is
geometrically checked in the work to the
positions by a common latching tube : Interchangable strickers for izod & chrpy
more stringent requirements of the
the upper position for charpy test and the lower positions. American Standard.
for Izod test. Positive pendupum lock in izod & chrpy The accuracy of the machine is then
*Interchangeable strikers for Izod, Charpy tests. positions. verified by PROOF TEST by testing test
Front guard provided for safety of operation. Safety guard for protection. specimens supplied by the NIST,
Watertown, Arsenal, USA. All two sets of
Manual brake for stopping pendulum oscillation A braking arrangement for stopping the
five specimen must agree with the
after sample failure. pendulum. nominal values within certain tolerance
Common specimen holder for Izod & Charpy test. Optional printer interface, Computer interface. specified.
Separate strikers for Izod & Charpy test.
TECHNICAL DATA :
RI-0.42/1.4 RI-300/RI-300(E) RI-300/RI-300(E)
Specifications RI-30 (ASTM)
Izod Test Charpy Test Izod Test
Pendulum drop angle 1200 1400 900 1400
Pendulum effective Wt. 1.3725 4.75 kg. 21.400 kg. 21.300 kg. 21.819 kg.

Striking velocity of pendulum 2.45 m/sec. 5.3466 m/sec. 3.857 m/sec. 5.182 m/sec.
Pendulum impact energy 0.42 kg-m 1.4 300 J 168 J 216 ft Ib
Min. Scale graduation 0.005 kg-m 2 J for RI-300 2 J for RI-300 2 ft Ib
0.07 0.5J for RI-300(E) 0.5J for RI-300(E)
Distance of axis of pendulum rotation from centre of
specimen / to specimen hit by pendulum 204 mm 815 mm 815 mm 775 mm
0.50% of impact energy 0.75% of max.
Max. Permissible loss by friction & Windage etc.
Impact energy
Charpy Test RI-30 (ASTM)
Izod Test Izod Test
Charpy Test
a) Striking edge a) Striking edge a) Striking edge a) Striking edge
0 0 0 0
Angle 30 Angle 30 Angle 75 Angle 30
Radius of curvature 3.2 mm Radius of curvature 2 mm Radius of curvature 0.7 mm Radius of curvature 8 mm
Width 18 mm Horizontal Relief angle 100 Width of tip 4 mm
0
Vertical relief angle 5
b) Support : b) Support : b) Support : b) Support :
For Gripping specimen Distance between arms 40 mm For Gripping specimen Distance between arms 40 mm
with dimension of Sloping Angle 00 with dimension of 10x10mm Relief Angle 100
12.7x12.7x63.5 mm Relief Angle 10
0
Radius of curvature 1 mm
Radius of curvature 1 mm
NOTCH
BROACHING
MACHINE
SGS-10 SERIES Technical description
V/U NOTCH BROACHING MACHINE When the casting /research
engineer is put with a tight tolerance
in properties, it is necessary to test the
· Highly precision.
accurate specimen. Notches are
· Tool guide for proper alignment.
especially critical in determining the
· Consistency in all specimen.
toughness for fracture. Close
· Simple clamping for specimen.
tolerance and fine surface finish in 'V'
· Bottom system for easy operation and 'U' notches to give correct value
· Notch as per during charpy or izod test.
Indian / International standards. SGS-10 series-broaching machine
can give significantly faster and
Achieve Better Surface Straightness, accurate finishing to the specimen.
Fitness accuracy, Closer angular tolerance, The machine will broach a notch in
& Sharp corner in single stroke. 10mm specimen to the Indian/
International standards.
U/V notch to the following specifications
ASTMA370 BS131 Part1 & Part 2&3
DIN50115 IS 1598-1977 IS 1499-1977

IZOD 'V' Notch machining tolerance as per IS 1598-1977


Nominal Machining tolerance (mm)
Description Dimension (mm) Ferrous Non-Ferrous

Thickness 10 ± 0.11 ±0.05


Width 10 ±0.11 ±0.05
Angle of notch 45 ±2 ±1
Root radius of notch 0.25 ±0.025 ±0.025
Depth below notch 8 ±0.045 ±0.025
Distance of notch from
the end of test piece and
from adjustment notch 28 ±0.420 ±0.420
Angle between plane of
symmetry of notch and the 90 ±2 ±1
axis of the test piece

SITE CALIBRATION IN THE PRESENCE OF INSPECTING AUTHORITIES UNDERTAKEN


We are registered with DGS&D , NSIC as approved suppliers. Also we are registered with SSI, EEPC, Govt. of India, Ministry of Defence and D&B D-U-N-S.
We are an ISO 9001-2000 certified company
Due to constant research and development, specifications and features are subject to change without notice.
8/579/11A, Sangli Road, ICHALKARANJI - 416 115.
Dist. Kolhapur, Maharashtra (INDIA)
Tel. & Fax: (91-230) 2430105, 2431834
R. 2439094, 2436263, Cell : +91-9822477799, +91-9822877799
Web : www.ratnakarentp.com Email : akudche@yahoo.com
For live catalogues : http://www.geocities.com/aakudche/index.html.